Economical Gas

mass Flow mEtErs

For clean Gases with

optional integral Display

FMA1700A/1800A Series

Standard

FMA1828A,

shown smaller

than actual size.

substitutes for many rotameter

applications. When used with the

FMA178BP portable battery pack,

the FMA1800A Series are ideal for

The FMA1700A/1800A Series

in-the-field calibration of flow meters

eletronic gas mass flow meters

or testing of air sampling equipment.

provide for monitoring the flow of a

wide variety of gases from 10 SCCM

The FMA178BP battery pack

includes batteries, recharger, and

up to 1000 SLM. Utilizing heat

carrying case with shoulder strap

transfer through a heated tube to

and belt loop. With the FMA178BP,

measure molecular gas flow rate,

the flow meter can operate in excess

the FMA1700A/1800A provides

of 40 hours; the batteries can be

measurement of direct gas mass

recharged at least 200 times.

flow rate, without the need to

compensate for variations in gas

The FMA1700A/1800A Series

temperature or pressure (within

require 12 to 26 Vdc power @

stated limits). They are available in

200 mA maximum, which can be

an economical aluminum/brass

supplied by the FMA178PW plug-in

construction for typical gas flows

socket power supply. The

and a 316 SS construction for

electronics are reverse polarity

applications requiring more

protected and has externally-

corrosion resistance. The

accessible fusing. Model number

FMA1700A series without

FMA178C (supplied separately)

integral display is supplied with a

provides a mating 9-pin “D”

field selectable analog 0 to 5 Vdc

connector with 3 feet of ribbon cable

or 4 to 20 mA output for remote

for accessing the 0 to 5 Vdc output

monitoring; the FMA1800A series

signal and power input connections

has both an integral 3¹⁄₂ digit display

(use FMA178C-MA for 4 to 20 mA

and analog output. The display is

output signal connection).

tiltable over 90 degrees for viewing

The LCD supplied with the

convenience. The display is

FMA1800A Series is connected

calibrated standard to read out

to the lower electronics via a

directly in SCCM or SLM for

modular plug. The LCD can be

nitrogen (other gas calibrations

remotely located by purchasing an

available on special order).

FMA18RC remote cable assembly-

Due to their low cost, digital

you must then build your own

display, analog output capability,

assembly for panel mounting

and insensitivity to variations in gas

the LCD.

U Reads Gas Mass Flow

Without Temperature

or Pressure Compensation

U Available in Economical

Aluminum or Corrosion-

Resistant 316 SS

U Tiltable LCD Display

for Easy Reading

U NIST Traceable

temperature and pressure, the

Calibration Included

FMA1700A/1800A Series are ideal

SPECIFICATIONS

Accuracy: ±1.5% of full scale,

including linearity over 15 to 25°C and

5 to 60 psia (0.35 to 4.2 kg/cm

2

)

Repeatability: ±0.5% of full scale

and for units ≥100 scm from 0 to 20%

of range

Temperature Coefficient: 0.15% of full

scale per °C or better

Pressure Coefficient: 0.01% of full

scale per psi (0.07 bar)

Maximum Pressure Drop:

SLM in. W.C. SLM in W.C.

10 1 80 168

20 14 100 227

30 34 200 112

50 90 500 140

60 129 1000 252

Response Time: 800 msec time

constant; 2 seconds (typical) to within

±2% of set flow rate over 25 to 100% of

full scale

Maximum Gas Pressure: 500 psig

(35 kg/cm

2

gage);1000 psig (70 kg/cm

2

gage) for ranges up to 100 SLM;

20 psig optimum

Gas and Ambient Temperature:

0 to 50°C (0 to 122°F)

Leak Integrity: 1 x 10

-

std cc/sec

of helium maximum to

outside environment

Ma terials in Fluid Contact:

Aluminum Models: Anodized

aluminum, 316 SS, brass and

FKM O-rings

9

D-11

Stainless Steel Models: 316 SS

Output Signal

and FKM O-rings

Linear 0 to 5 Vdc:

minimum load

1000 Ω

Transducer Power:

4 to 20 mA: 50 to 250 Ω

200 mA maximum

12 Vdc @

loop resistance

Shipping Weight:

Compliance:

1.1 kg (2.5 lb)

EN50082-1

EN55011 class 1, class B;

See instruction manual for dimensions

To Order

Model No.

Aluminum/Brass

Model No.

Body with Display

Stainless Steel

Body with Display

Aluminum/Brass

Body without Display

Stainless Steel

Body without DisplayCode**

RangeMaximum

Flow Rate

FMA1802AFMA1802A-STFMA1702AFMA1702A-ST

0210 sccm

FMA1804AFMA1804A-STFMA1704AFMA1704A-ST

0420 sccm

FMA1806AFMA1806A-STFMA1706AFMA1706A-ST

0650 sccm

FMA1808AFMA1808A-STFMA1708AFMA1708A-ST

08100 sccm

FMA1810AFMA1810A-STFMA1710AFMA1710A-ST

10200 sccm

FMA1812AFMA1812A-STFMA1712AFMA1712A-ST

12500 sccm

FMA1814AFMA1814A-STFMA1714AFMA1714A-ST

141 SLM

FMA1816AFMA1816A-STFMA1716AFMA1716A-ST

162 SLM

FMA1818AFMA1818A-STFMA1718AFMA1718A-ST

185 SLM

FMA1820AFMA1820A-STFMA1720AFMA1720A-ST

2010 SLM

FMA1823AFMA1823A-STFMA1723AFMA1723A-ST

2315 SLM

FMA1824AFMA1824A-STFMA1724AFMA1724A-ST

2420 SLM

FMA1826AFMA1826A-STFMA1726AFMA1726A-ST

2630 SLM

FMA1827AFMA1827A-STFMA1727AFMA1727A-ST

2740 SLM

FMA1828AFMA1828A-STFMA1728AFMA1728A-ST

2850 SLM

FMA1840AFMA1840A-STFMA1740AFMA1740A-ST

4060 SLM

FMA1841AFMA1841A-STFMA1741AFMA1741A-ST

4180 SLM

FMA1842AFMA1842A-STFMA1742AFMA1742A-ST

42100 SLM

FMA1843AFMA1843A-STFMA1743AFMA1743A-ST

43200 SLM

FMA1844AFMA1844A-STFMA1744AFMA1744A-ST

44500 SLM

FMA1845AFMA1845A-STFMA1745AFMA1745A-ST

451000 SLM*

*

Comes with dual

3

**

4

FNPT connections instead of compression fittings.

Insert range code, see table above.

Flow ranges specified are for nitrogen or air at 20 psig. When used for other gases, a multiplication factor is used to determine the flow rate,

and the digital display must be rescaled in the field. To request a custom calibration add the gas abbreviation and pressure as a suffix to the

model number.

Accessories

Model ption

FMA178PW

Socket plug-in power supply for 115 Vac (recommended)

FMA178C

Female 9-pin D-connector with 1 m (3') of ribbon cable, 0 to 5 Vdc output

FMA178C-MA

Female 9-pin D-connector with 1 m (3') of ribbon cable, 4 to 20 mA output

FMA178PW-220VAC

Socket plug-in power supply for 220 Vac, VDE plug type

FMA178BP

Portable battery pack, with recharger for 115 Vac

FMA178BP-220VAC

Portable battery pack, with recharger for 220 Vac

FMA18RC10

3 m (10') cable for remotely locating LCD of FMA1800

FMA18RC25

7.6 m (25') cable for remotely locating LCD of FMA1800

Comes complete with compression fittings, operator’s manual, and NIST certificate. Power supplies sold separately.

For oxygen cleaned units, add suffix “-02CLEAN” to model number for additional cost.

Ordering Examples:

from 0 to 500 SCCM.

FMA1712A, AL/BR body flow meter without an integral display, calibrated for nitrogen at 20 psig, ambient temperature

FMA1810A, AL/BR body with display and FMA178PW, power supply.

D-12

D

2024年3月29日发(作者:虞巧)

Economical Gas

mass Flow mEtErs

For clean Gases with

optional integral Display

FMA1700A/1800A Series

Standard

FMA1828A,

shown smaller

than actual size.

substitutes for many rotameter

applications. When used with the

FMA178BP portable battery pack,

the FMA1800A Series are ideal for

The FMA1700A/1800A Series

in-the-field calibration of flow meters

eletronic gas mass flow meters

or testing of air sampling equipment.

provide for monitoring the flow of a

wide variety of gases from 10 SCCM

The FMA178BP battery pack

includes batteries, recharger, and

up to 1000 SLM. Utilizing heat

carrying case with shoulder strap

transfer through a heated tube to

and belt loop. With the FMA178BP,

measure molecular gas flow rate,

the flow meter can operate in excess

the FMA1700A/1800A provides

of 40 hours; the batteries can be

measurement of direct gas mass

recharged at least 200 times.

flow rate, without the need to

compensate for variations in gas

The FMA1700A/1800A Series

temperature or pressure (within

require 12 to 26 Vdc power @

stated limits). They are available in

200 mA maximum, which can be

an economical aluminum/brass

supplied by the FMA178PW plug-in

construction for typical gas flows

socket power supply. The

and a 316 SS construction for

electronics are reverse polarity

applications requiring more

protected and has externally-

corrosion resistance. The

accessible fusing. Model number

FMA1700A series without

FMA178C (supplied separately)

integral display is supplied with a

provides a mating 9-pin “D”

field selectable analog 0 to 5 Vdc

connector with 3 feet of ribbon cable

or 4 to 20 mA output for remote

for accessing the 0 to 5 Vdc output

monitoring; the FMA1800A series

signal and power input connections

has both an integral 3¹⁄₂ digit display

(use FMA178C-MA for 4 to 20 mA

and analog output. The display is

output signal connection).

tiltable over 90 degrees for viewing

The LCD supplied with the

convenience. The display is

FMA1800A Series is connected

calibrated standard to read out

to the lower electronics via a

directly in SCCM or SLM for

modular plug. The LCD can be

nitrogen (other gas calibrations

remotely located by purchasing an

available on special order).

FMA18RC remote cable assembly-

Due to their low cost, digital

you must then build your own

display, analog output capability,

assembly for panel mounting

and insensitivity to variations in gas

the LCD.

U Reads Gas Mass Flow

Without Temperature

or Pressure Compensation

U Available in Economical

Aluminum or Corrosion-

Resistant 316 SS

U Tiltable LCD Display

for Easy Reading

U NIST Traceable

temperature and pressure, the

Calibration Included

FMA1700A/1800A Series are ideal

SPECIFICATIONS

Accuracy: ±1.5% of full scale,

including linearity over 15 to 25°C and

5 to 60 psia (0.35 to 4.2 kg/cm

2

)

Repeatability: ±0.5% of full scale

and for units ≥100 scm from 0 to 20%

of range

Temperature Coefficient: 0.15% of full

scale per °C or better

Pressure Coefficient: 0.01% of full

scale per psi (0.07 bar)

Maximum Pressure Drop:

SLM in. W.C. SLM in W.C.

10 1 80 168

20 14 100 227

30 34 200 112

50 90 500 140

60 129 1000 252

Response Time: 800 msec time

constant; 2 seconds (typical) to within

±2% of set flow rate over 25 to 100% of

full scale

Maximum Gas Pressure: 500 psig

(35 kg/cm

2

gage);1000 psig (70 kg/cm

2

gage) for ranges up to 100 SLM;

20 psig optimum

Gas and Ambient Temperature:

0 to 50°C (0 to 122°F)

Leak Integrity: 1 x 10

-

std cc/sec

of helium maximum to

outside environment

Ma terials in Fluid Contact:

Aluminum Models: Anodized

aluminum, 316 SS, brass and

FKM O-rings

9

D-11

Stainless Steel Models: 316 SS

Output Signal

and FKM O-rings

Linear 0 to 5 Vdc:

minimum load

1000 Ω

Transducer Power:

4 to 20 mA: 50 to 250 Ω

200 mA maximum

12 Vdc @

loop resistance

Shipping Weight:

Compliance:

1.1 kg (2.5 lb)

EN50082-1

EN55011 class 1, class B;

See instruction manual for dimensions

To Order

Model No.

Aluminum/Brass

Model No.

Body with Display

Stainless Steel

Body with Display

Aluminum/Brass

Body without Display

Stainless Steel

Body without DisplayCode**

RangeMaximum

Flow Rate

FMA1802AFMA1802A-STFMA1702AFMA1702A-ST

0210 sccm

FMA1804AFMA1804A-STFMA1704AFMA1704A-ST

0420 sccm

FMA1806AFMA1806A-STFMA1706AFMA1706A-ST

0650 sccm

FMA1808AFMA1808A-STFMA1708AFMA1708A-ST

08100 sccm

FMA1810AFMA1810A-STFMA1710AFMA1710A-ST

10200 sccm

FMA1812AFMA1812A-STFMA1712AFMA1712A-ST

12500 sccm

FMA1814AFMA1814A-STFMA1714AFMA1714A-ST

141 SLM

FMA1816AFMA1816A-STFMA1716AFMA1716A-ST

162 SLM

FMA1818AFMA1818A-STFMA1718AFMA1718A-ST

185 SLM

FMA1820AFMA1820A-STFMA1720AFMA1720A-ST

2010 SLM

FMA1823AFMA1823A-STFMA1723AFMA1723A-ST

2315 SLM

FMA1824AFMA1824A-STFMA1724AFMA1724A-ST

2420 SLM

FMA1826AFMA1826A-STFMA1726AFMA1726A-ST

2630 SLM

FMA1827AFMA1827A-STFMA1727AFMA1727A-ST

2740 SLM

FMA1828AFMA1828A-STFMA1728AFMA1728A-ST

2850 SLM

FMA1840AFMA1840A-STFMA1740AFMA1740A-ST

4060 SLM

FMA1841AFMA1841A-STFMA1741AFMA1741A-ST

4180 SLM

FMA1842AFMA1842A-STFMA1742AFMA1742A-ST

42100 SLM

FMA1843AFMA1843A-STFMA1743AFMA1743A-ST

43200 SLM

FMA1844AFMA1844A-STFMA1744AFMA1744A-ST

44500 SLM

FMA1845AFMA1845A-STFMA1745AFMA1745A-ST

451000 SLM*

*

Comes with dual

3

**

4

FNPT connections instead of compression fittings.

Insert range code, see table above.

Flow ranges specified are for nitrogen or air at 20 psig. When used for other gases, a multiplication factor is used to determine the flow rate,

and the digital display must be rescaled in the field. To request a custom calibration add the gas abbreviation and pressure as a suffix to the

model number.

Accessories

Model ption

FMA178PW

Socket plug-in power supply for 115 Vac (recommended)

FMA178C

Female 9-pin D-connector with 1 m (3') of ribbon cable, 0 to 5 Vdc output

FMA178C-MA

Female 9-pin D-connector with 1 m (3') of ribbon cable, 4 to 20 mA output

FMA178PW-220VAC

Socket plug-in power supply for 220 Vac, VDE plug type

FMA178BP

Portable battery pack, with recharger for 115 Vac

FMA178BP-220VAC

Portable battery pack, with recharger for 220 Vac

FMA18RC10

3 m (10') cable for remotely locating LCD of FMA1800

FMA18RC25

7.6 m (25') cable for remotely locating LCD of FMA1800

Comes complete with compression fittings, operator’s manual, and NIST certificate. Power supplies sold separately.

For oxygen cleaned units, add suffix “-02CLEAN” to model number for additional cost.

Ordering Examples:

from 0 to 500 SCCM.

FMA1712A, AL/BR body flow meter without an integral display, calibrated for nitrogen at 20 psig, ambient temperature

FMA1810A, AL/BR body with display and FMA178PW, power supply.

D-12