最新消息: USBMI致力于为网友们分享Windows、安卓、IOS等主流手机系统相关的资讯以及评测、同时提供相关教程、应用、软件下载等服务。

CNC数控系统通讯参数设置

IT圈 admin 36浏览 0评论

2024年4月20日发(作者:奕丹溪)

CNC数控系统通讯参数设置

来源:/

AllenBradley

(美国:AB)

AllenBradley 8600

Parameter

Baud Rate

Parity

Databits

Stop Bits

Value

2400

E

7

2

Comments

Acramatic

(美国:辛辛那提·米拉克龙)

Acramatic 850 (SX)

Parameter

Baud Rate

Parity

Databits

Stop Bits

Value

2400

N

8

1

Comments

Also set these values in the DNC software

Drip Feed ?

We do not believe drip feed is possible with this controller

See bottom of this page for Cable diagrams

Anilam

(美国:艾科瑞)

Anilam Crusader

Parameter

Group 1

Group 2

Group 3

Group 4

Group 5

Group 6

Value Comments

AUX 2767 7 Data bits

AUX 2772 Even Parity

AUX 2784 Baud Rate 1200

AUX 2790 No Flow Control

AUX 2700 Send from Crusader to PC

AUX 2701 Receive data in Crusdare (From PC)

1 / 15

Bosch

(美国:博世·力士乐)

Bosch CC220 and CC320

Parameter

Device

DCR

Status

DFS

Time Out

Value

Port

9600

10 SEC

Comments

(V240,1)

Baud Rate

RECOGNISE WITH LEADER WITH TRAILER

SW Control

Haas

(美国:哈斯)

Haas

Parameter Value

11

12

13

14

37

24

25

41

50

54

69

70

9600

Even

1

Xon/Xoff

7

None

CR,LF

On

Xon/Xoff

9600

Off

On

Comments

Boss

Bridgeport Boss

Parameter

Baud Rate

Parity

Databits

Stop Bits

Value

4800

Even

7

1

Comments

USE DNC Port B

See Cable diagrams below

2 / 15

DeltaDynaPath

(美国: )

Delta Dynapath

Parameter

Baud Rate

Databits

Parity

Stop bits

Value

Any

7

Even

1

Comments

Suggest 2400 but not higher than 9600)

FadalCNC

(美国:法道)

Fadal 88

Parameter

Baud Rate

Databits

Parity

Stop bits

Value

9600

7

Even

1

Comments

Suggest 2400 but not higher than 9600)

Fanuc

(日本:发那科)

Fanuc i(M/T)

Parameter

0000

0020

0100

0101

0102

0103

0138

TV Check

Value

0000 0010

0

0010 1000

1000 1001

0

11

1000 0000

0

Comments

9 = 2400,10 = 4800,11 = 9600* (recommended)

0 = TV Check OFF (1= TV Check ON - Never enable TV Check)

1 = ISO (0=EIA Never use EIA)

Punch Code

1

I/O Channel

0

PWE

1

Drip Feed ?

Select Auto (DNC) mode on the control - Press Cycle Start.

选择自动(DNC)控制状态,按(循环启动)。

Then go to the computer, prepare the program and click 'Send'. When data

begins to flow the machine will start moving.

然后去电脑,准备程序,点击“发送”,当数据开始传送时,机床就会开始移动。

Fanuc 0(M/T)

3 / 15

Parameter

0002

0038

0552

TV On/Off

ISO

I/O

PWE

TAPEF

Value Comments

1000 0001

0100 0000

11

0

1

0

1

0

9 = 2400,10 = 4800,11 = 9600* (recommended)

0 = TV Check OFF (1= TV Check ON - Never enable TV Check)

1 = ISO (0=EIA Never use EIA)

Drip Feed ?

To drip feed enable para G127.5

使G127.5 DNC操作信号动作。

Select Auto (DNC) mode on the control - Press Cycle Start.

选择自动(DNC)控制状态,按(循环启动)。

Then go to the computer, prepare the program and click 'Send'. When data

begins to flow the machine will start moving.

然后去电脑,准备程序,点击“发送”,当数据开始传送时,机床就会开始移动。

Fanuc 3(M/T)

Parameter

0005

0068

ISO

I/O

Value

0000 0001

10

1

0

Comments

9 = 2400,10 = 4800* (recommended),11 = 9600

0 = TV Check OFF (1= TV Check ON - Never enable TV Check)

1 = ISO (0=EIA Never use EIA)

TV On/Off

0

Fanuc 6,9(M/T) ,0P

Parameter

340

341

311

Value

2

2

Comments

0011 1000 = 2400

0011 1001 = 4800

0011 1010 = 9600 * (recommended)

TV Check

Punch Code

Input Unit

0

1

0

0 = TV Check OFF (1= TV Check ON - Never enable TV Check)

1 = ISO (0=EIA Never use EIA)

0011 1010 Baud rate - see table below for valid options.

Input Device 1

1

Input Device 2

1

Fanuc 10,11,12,15 (M/T)

Parameter

0000

Value Comments

****1010

4 / 15

0011

0020

0021

2201

5001

5002

5003

5110

5111

5112

5120

5121

5122

5130

5131

5132

******00

1

1

******00

1

2

3

4

2

10

4

2

10

4

2

10

* Baud rate - see table below for valid options.

* Baud rate - see table below for valid options.

* Baud rate - see table below for valid options.

9 = 2400

10 = 4800 * (recommended)

11 = 9600

TV Check

ISO

Output

Device

Drip Feed ?

0

0

1

0 = TV Check OFF (1= TV Check ON - Never enable TV Check)

0 = ISO (1=EIA Never use EIA)

Input Device

1

Select Tape mode on the control - Press Cycle Start.

选择TAPE(磁带)控制状态,按(循环启动)。

Then go to the computer, prepare the program and click 'Send'. When data

begins to flow the machine will start moving.

然后去电脑,准备程序,点击“发送”,当数据开始传送时,机床就会开始移动。

Note: Not all fanuc of this type can drip feed - must be enabled in the

control.

Fanuc 16,18,21 (M/T)

Parameter

0000

0020

0100

0101

0102

0103

TV Check

Punch Code

Value

0

Comments

0000 0010

0010 1000

1000 1001

0

10

0

1

9 = 2400,10 = 4800* (recommended),11 = 9600

0 = TV Check OFF (1= TV Check ON - Never enable TV Check)

1 = ISO (0=EIA Never use EIA)

5 / 15

I/O Channel

Drip Feed ?

0

Tape Format

0

Select TAPE mode on the control - Press Cycle Start.

选择TAPE(磁带)控制状态,按(循环启动)。

Then go to the computer, prepare the program and click 'Send'. When data

begins to flow the machine will start moving.

然后去电脑,准备程序,点击“发送”,当数据开始传送时,机床就会开始移动。

Mazak

(日本:马扎克)

Mazak M Plus / T Plus

Parameter Value

User Parameter #5

G1

G2

G3

G5

G6

G10

G12

G13

G17

G31

G33

G34

G39

G40

G48

1

3

0

3

1

3

0

50

= Baud Rate 9600

= 2 Stop Bits

= Even Parity

= 8 Data Bits (Set DNC to software to 7 Databits)

Use xOn/xOff flow control (DC1 and DC3)

Do not use DC2 and DC4)

Comments

0000 0000

0000 0000

50

10

0000 0100

0000 0000

0

Note : Even though the Mazak is set to 8 Databits - ensure than the

DNC software is set to 7 databits.

In the DNC software select xOn/xOff flow control

Mazak M32

Parameter Value Comments

G19

G20

G22

G23

G24

G25

G26

2

3

0

3

1

0

0

2 = 4800 3 = 2400

= 2 Stop Bits

= Even Parity

= 8 Data Bits (Set DNC to software to 7 Databits)

6 / 15

G27

G28

G29

0

0

3

Use ISO code

Note : Even though the Mazak is set to 8 Databits - ensure than the DNC

software is set to 7 databits.

In the DNC software select xOn/xOff flow control

Mazak T32 - M2

Parameter Value

I 1

I 2

I 3

I 4

I 5

I 6

I 7

I 8

I 9

I 10

I 11

I 12

I 13

I 14

I 15

I 16

I 24

I 58

Mazak T2

Parameter Value Comments

A15

A16

A17

A18

A19

A20

A21

A22

A23

A24

206

1

6

6

0

1

1

10

10

0

= No Parity ( But in the DNC software select Even Parity )

= Baud rate 4800

Use ISO

TV Check Off

7 / 15

Comments

Note : Even though the Mazak may be set to 8 Databits No Parity -

ensure that the DNC software is set to 7 databits with Even Parity.

2

3

0

0

3

3

1

5

0

1

1

0

0

0

30

0

0

0000 0000

A30

A31

A32

3

109

70

Note : Even though the Mazak is set to 8 Databits No Parity - ensure that

the DNC software is set to 7 databits with Even Parity.

Mitsubishi

(日本:三菱)

Mitsubishi 300-500

Parameter Value

1

2

3

6

7

2

3

4

5

6

7

11

12

Mitsubish M50,60/60s,E60/68,M64/65/66

Parameter Value

9001

9002

9003

9004

9005

9101

9201

9102

9202

9103

9203

2

1

2

0

2

Out/In

Out/In

2

2

1

1

Comments

Input Port

Input Device

Out Port

Out device

Tape Mode

Baud rate 4800

1 Stop Bit

8 / 15

Comments

I/O Base parameters

1

1

0

0

200

2

3

0

1

3

3

3

1

I/O Devive parameters

I/O Base parameters

I/O Devive parameters

9104

9204

9105

9205

9106

9206

9108

9208

9109

9209

1

1

1

1

2

2

3

3

1

1

Use Parity = Yes

Parity = Even

7 Databits

Use xOnx/Off (DC1 and DC3)

Okuma

(日本:大隈)

Okuma 5000 / 7000

Parameter Value

1

34

39

44

45

46

54

57

Punch

Read

0

10

4800

0

0

0

1

90

Comments

number of spaces/ bytes of tape leader

Baud Rate

0000 1011 Optional parameter bits #1 (ISO Code)

1010 1010 Okuma 7000 Opt Para #8

1010 0010 Optional parameter bits #12 (Stop Bits/Parity)

Go to the 'Edit mode' [F3] (PIP), [F2] (Punch), type file name, then [Return]

Go to the 'Edit mode' [F3] (PIP), [F1] (Read), [Return]

Function

Yasnac

(日本:安川)

Yasnac LX MX

Parameter

6000

6001

6003

6021

6022

Value Comments

1xxx xxxx x = don't change

1xxx xxxx (Maybe only required on MX-2)

xxx1 xxx1

x111 xx1x (Maybe only required on LX/MX-1)

xxxx xx11

6026 / 6028

0001 1000 Baud rate - 2400

9 / 15

7 Data bits,Parity Even,2 Stop bits

Amada

(日本:天田)

Amada

Parameter

Baud Rate

Parity

Databits

Stop Bits

Dec Inp

Value

2400

Even

7

2

0

Comments

Also set these values in the DNC software

1=ISO (Do not use 0 EIA)

See cable diagrams below

Punch Code

1

Heidenhain

(德国:海德汉)

Heidenhain TNC 145

Parameter Value Comments

Baud

rate

Parity

Databits

2400

Even

7

In the DNC software select RTS/CTS flow control

DNC Software should insert STX and ETX codes into the transmit data -

For example with easyDnc 4.0 this is acheived in the DNC Setup window

by selecting 'Advanced' and select these options from the drop-lists.

ASCII Start Code = STX (02)

ASCII End Code = ETX (03)

Stop Bits

2

Heidenhain TNC 150

Parameter Value

MP92

MP71

1

3

Comments

Select Multi Func.

(Same as in the DNC software )

In the DNC software select RTS/CTS flow control

DNC Software should insert STX and ETX codes into the transmit data -

For example with easyDnc 4.7 this is acheived in the DNC Setup window

by selecting 'Advanced' and select these options from the drop-lists.

ASCII Start Code = STX (02)

ASCII End Code = ETX (03)

10 / 15

BaudRate

2400

Heidenhain TNC 155,355

Parameter Value Comments

MP232

MP71

MP222

0

515

104

in the DNC software Set Baud rate 2400 -7 DataBits -Even -2 StopBits

In the DNC software select RTS/CTS flow control

DNC Software should insert STX and ETX codes into the transmit data - For

example with easyDnc 4.0 this is acheived in the DNC Setup window by

selecting 'Advanced' and select these options from the drop-lists.

ASCII Start Code = STX (02)

ASCII End Code = ETX (03)

Heidenhain TNC 415,425

Parameter

Device

MP 5200.1

MP 5201.1

MP 5020.1

MP 5030.1

Value

2

3

104

0

Comments

in the DNC software Set Baud rate 2400 -7 DataBits -Even -2

StopBits

In the DNC software select RTS/CTS flow control

DNC Software should insert STX and ETX codes into the transmit

data - For example with easyDnc 4.0 this is acheived in the DNC Setup

window by selecting 'Advanced' and select these options from the

drop-lists.

ASCII Start Code = STX (02)

ASCII End Code = ETX (03)

EXT 2

Heidenhain TNC 2500

Parameter

MP 5020

MP 5030

Value

100

0

Comments

in the DNC software Set Baud rate 2400 -7 DataBits -Even -2

StopBits

In the DNC software select RTS/CTS flow control

DNC Software should insert STX and ETX codes into the transmit

data - For example with easyDnc 4.0 this is acheived in the DNC Setup

window by selecting 'Advanced' and select these options from the

drop-lists.

ASCII Start Code = STX (02)

11 / 15

ASCII End Code = ETX (03)

Hinumerik

(德国:)

Hinumerik 2000,2100 (M/T)

Parameter Value

5010

5012

5011

5013

5016

RTS

0

0

Comments

1100 0101 = 2400 For other Baud Rates see the table below

1100 0101 Same as 5011 - For other Baud Rates see the table below

xx10 xxxx

Line 1

In the DNC software select RTS/CTS flow control

1100 0101 = 2400,1100 0110 = 4800

x = do not change

Hinumerik 3000 ,3100 (M/T)

Parameter Value

411

412

416

Comments

1110 1101 = 2400 For other Baud Rates see the table below

1110 1101 Same as 5011 - For other Baud Rates see the table below

1xxx xxx1

1110 1101 = 2400,1110 1110 = 4800

x = do not change

In the DNC software select RTS/CTS flow control

Sinumerik

(德国:西门子)

Sinumerik 3M and 3T

Parameter Value

411

412

416

Comments

1110 1101 = Baud Rate 2400

1110 1101 See below for other baud rates

1xxxxxx1

1110 1101 = 2400,1110 1110 = 4800

x = Do not change

Sinumerik 8M and 8T

Parameter Value

428

429

425

430

461

Comments

1110 1101 = Baud Rate 2400

1110 1101 See below for other baud rates

xxxx x0xx

xx0x xxxx

1110 1101 = 2400,1110 1110 = 4800

x = Do not change

x = Do not change

0000 0000

12 / 15

Sinumerik 810and 850 (M/T)

Parameter Value

5010

5012

5011

5013

0

0

Comments

1111 0101 = Baud Rate 2400

1111 0101 See below for other baud rates

1111 0101 = 2400,1111 0110 = 4800

RTS Line

1

Sinumerik 840D

Parameter

Serial

Device

Device Type

Protocol

Baud rate

Stop bits 2

Parity

Bit/character

Xoff character

EOT

Leader

Ready

EOB

Format

Value

1

Standard/WS800A

Universal

RTS/CTS (Hardware)

9600

2

Even

7

13

03

No

No

CRLF

Punch tape format

Comments

Xon character

11

Time out in Sec.

60

Traub

(德国:特劳伯)

Traub TX8

Parameter

#1

01

04

#2

12

Value

0

1

0

5

Comments

Parity

ISO

Baud Rate = 1200

13 / 15

Fagor

(西班牙:发格)

Fagor 80xx

Parameter Value Comments

In the control settings select

9 (Special Modes)

1 (General Parameters)

P000

P001

P002

P003

Fagor 8025T

Parameter Value Comments

In the control settings select

9 (Special Modes)

1 (General Parameters)

P000

P001

P002

P003

P605

7

2

2

0001 0000

Valid Baud Rates 2400, 4800 (Same as the DNC Software)

7 Databits

Even Parity

Stop Bits

DNC activate

7

2

2

Valid Baud Rates 2400, 4800 (Same as the DNC Software)

7 Databits

Even Parity

Stop Bits

After making changes - reset the controller

After making changes - reset the controller

传输故障的解决

1. 检查 PC和 CNC 的端口参数设置是否一致,波特率速度设置不宜太快(太快可能会

丢失数据),也不宜太慢(速度慢当然效率就低了) ;

2. 连接电缆是否有断线,接触不良,焊接是否正确;

3. 通讯软件选择不对,有一些系统必须用原厂的通讯软件;

4. 传输的文件格式不正确;

5. 有较大干扰,选择优质屏蔽电缆做传输线;

6. 如果上述都正确,那就是端口损坏。

另外,曾经使用过数据传送,参数设置也正确的情况下,同样也会发生传送故障,这时

把PC的FIFO缓冲区取消或者使“接收缓冲区”与“传输缓冲区”为最低即可。

置方法如下:

打开PC“控制面板”—“系统”—“硬件”—“设备管理器”—“端口”—“通讯端

口”,右键,“属性”—“端口设置”—“高级”—“使用FIFO缓存”,使“接收缓冲区”与

14 / 15

“传输缓冲区”为最低即可,或者取消“使用FIFO缓存”。

15 / 15

2024年4月20日发(作者:奕丹溪)

CNC数控系统通讯参数设置

来源:/

AllenBradley

(美国:AB)

AllenBradley 8600

Parameter

Baud Rate

Parity

Databits

Stop Bits

Value

2400

E

7

2

Comments

Acramatic

(美国:辛辛那提·米拉克龙)

Acramatic 850 (SX)

Parameter

Baud Rate

Parity

Databits

Stop Bits

Value

2400

N

8

1

Comments

Also set these values in the DNC software

Drip Feed ?

We do not believe drip feed is possible with this controller

See bottom of this page for Cable diagrams

Anilam

(美国:艾科瑞)

Anilam Crusader

Parameter

Group 1

Group 2

Group 3

Group 4

Group 5

Group 6

Value Comments

AUX 2767 7 Data bits

AUX 2772 Even Parity

AUX 2784 Baud Rate 1200

AUX 2790 No Flow Control

AUX 2700 Send from Crusader to PC

AUX 2701 Receive data in Crusdare (From PC)

1 / 15

Bosch

(美国:博世·力士乐)

Bosch CC220 and CC320

Parameter

Device

DCR

Status

DFS

Time Out

Value

Port

9600

10 SEC

Comments

(V240,1)

Baud Rate

RECOGNISE WITH LEADER WITH TRAILER

SW Control

Haas

(美国:哈斯)

Haas

Parameter Value

11

12

13

14

37

24

25

41

50

54

69

70

9600

Even

1

Xon/Xoff

7

None

CR,LF

On

Xon/Xoff

9600

Off

On

Comments

Boss

Bridgeport Boss

Parameter

Baud Rate

Parity

Databits

Stop Bits

Value

4800

Even

7

1

Comments

USE DNC Port B

See Cable diagrams below

2 / 15

DeltaDynaPath

(美国: )

Delta Dynapath

Parameter

Baud Rate

Databits

Parity

Stop bits

Value

Any

7

Even

1

Comments

Suggest 2400 but not higher than 9600)

FadalCNC

(美国:法道)

Fadal 88

Parameter

Baud Rate

Databits

Parity

Stop bits

Value

9600

7

Even

1

Comments

Suggest 2400 but not higher than 9600)

Fanuc

(日本:发那科)

Fanuc i(M/T)

Parameter

0000

0020

0100

0101

0102

0103

0138

TV Check

Value

0000 0010

0

0010 1000

1000 1001

0

11

1000 0000

0

Comments

9 = 2400,10 = 4800,11 = 9600* (recommended)

0 = TV Check OFF (1= TV Check ON - Never enable TV Check)

1 = ISO (0=EIA Never use EIA)

Punch Code

1

I/O Channel

0

PWE

1

Drip Feed ?

Select Auto (DNC) mode on the control - Press Cycle Start.

选择自动(DNC)控制状态,按(循环启动)。

Then go to the computer, prepare the program and click 'Send'. When data

begins to flow the machine will start moving.

然后去电脑,准备程序,点击“发送”,当数据开始传送时,机床就会开始移动。

Fanuc 0(M/T)

3 / 15

Parameter

0002

0038

0552

TV On/Off

ISO

I/O

PWE

TAPEF

Value Comments

1000 0001

0100 0000

11

0

1

0

1

0

9 = 2400,10 = 4800,11 = 9600* (recommended)

0 = TV Check OFF (1= TV Check ON - Never enable TV Check)

1 = ISO (0=EIA Never use EIA)

Drip Feed ?

To drip feed enable para G127.5

使G127.5 DNC操作信号动作。

Select Auto (DNC) mode on the control - Press Cycle Start.

选择自动(DNC)控制状态,按(循环启动)。

Then go to the computer, prepare the program and click 'Send'. When data

begins to flow the machine will start moving.

然后去电脑,准备程序,点击“发送”,当数据开始传送时,机床就会开始移动。

Fanuc 3(M/T)

Parameter

0005

0068

ISO

I/O

Value

0000 0001

10

1

0

Comments

9 = 2400,10 = 4800* (recommended),11 = 9600

0 = TV Check OFF (1= TV Check ON - Never enable TV Check)

1 = ISO (0=EIA Never use EIA)

TV On/Off

0

Fanuc 6,9(M/T) ,0P

Parameter

340

341

311

Value

2

2

Comments

0011 1000 = 2400

0011 1001 = 4800

0011 1010 = 9600 * (recommended)

TV Check

Punch Code

Input Unit

0

1

0

0 = TV Check OFF (1= TV Check ON - Never enable TV Check)

1 = ISO (0=EIA Never use EIA)

0011 1010 Baud rate - see table below for valid options.

Input Device 1

1

Input Device 2

1

Fanuc 10,11,12,15 (M/T)

Parameter

0000

Value Comments

****1010

4 / 15

0011

0020

0021

2201

5001

5002

5003

5110

5111

5112

5120

5121

5122

5130

5131

5132

******00

1

1

******00

1

2

3

4

2

10

4

2

10

4

2

10

* Baud rate - see table below for valid options.

* Baud rate - see table below for valid options.

* Baud rate - see table below for valid options.

9 = 2400

10 = 4800 * (recommended)

11 = 9600

TV Check

ISO

Output

Device

Drip Feed ?

0

0

1

0 = TV Check OFF (1= TV Check ON - Never enable TV Check)

0 = ISO (1=EIA Never use EIA)

Input Device

1

Select Tape mode on the control - Press Cycle Start.

选择TAPE(磁带)控制状态,按(循环启动)。

Then go to the computer, prepare the program and click 'Send'. When data

begins to flow the machine will start moving.

然后去电脑,准备程序,点击“发送”,当数据开始传送时,机床就会开始移动。

Note: Not all fanuc of this type can drip feed - must be enabled in the

control.

Fanuc 16,18,21 (M/T)

Parameter

0000

0020

0100

0101

0102

0103

TV Check

Punch Code

Value

0

Comments

0000 0010

0010 1000

1000 1001

0

10

0

1

9 = 2400,10 = 4800* (recommended),11 = 9600

0 = TV Check OFF (1= TV Check ON - Never enable TV Check)

1 = ISO (0=EIA Never use EIA)

5 / 15

I/O Channel

Drip Feed ?

0

Tape Format

0

Select TAPE mode on the control - Press Cycle Start.

选择TAPE(磁带)控制状态,按(循环启动)。

Then go to the computer, prepare the program and click 'Send'. When data

begins to flow the machine will start moving.

然后去电脑,准备程序,点击“发送”,当数据开始传送时,机床就会开始移动。

Mazak

(日本:马扎克)

Mazak M Plus / T Plus

Parameter Value

User Parameter #5

G1

G2

G3

G5

G6

G10

G12

G13

G17

G31

G33

G34

G39

G40

G48

1

3

0

3

1

3

0

50

= Baud Rate 9600

= 2 Stop Bits

= Even Parity

= 8 Data Bits (Set DNC to software to 7 Databits)

Use xOn/xOff flow control (DC1 and DC3)

Do not use DC2 and DC4)

Comments

0000 0000

0000 0000

50

10

0000 0100

0000 0000

0

Note : Even though the Mazak is set to 8 Databits - ensure than the

DNC software is set to 7 databits.

In the DNC software select xOn/xOff flow control

Mazak M32

Parameter Value Comments

G19

G20

G22

G23

G24

G25

G26

2

3

0

3

1

0

0

2 = 4800 3 = 2400

= 2 Stop Bits

= Even Parity

= 8 Data Bits (Set DNC to software to 7 Databits)

6 / 15

G27

G28

G29

0

0

3

Use ISO code

Note : Even though the Mazak is set to 8 Databits - ensure than the DNC

software is set to 7 databits.

In the DNC software select xOn/xOff flow control

Mazak T32 - M2

Parameter Value

I 1

I 2

I 3

I 4

I 5

I 6

I 7

I 8

I 9

I 10

I 11

I 12

I 13

I 14

I 15

I 16

I 24

I 58

Mazak T2

Parameter Value Comments

A15

A16

A17

A18

A19

A20

A21

A22

A23

A24

206

1

6

6

0

1

1

10

10

0

= No Parity ( But in the DNC software select Even Parity )

= Baud rate 4800

Use ISO

TV Check Off

7 / 15

Comments

Note : Even though the Mazak may be set to 8 Databits No Parity -

ensure that the DNC software is set to 7 databits with Even Parity.

2

3

0

0

3

3

1

5

0

1

1

0

0

0

30

0

0

0000 0000

A30

A31

A32

3

109

70

Note : Even though the Mazak is set to 8 Databits No Parity - ensure that

the DNC software is set to 7 databits with Even Parity.

Mitsubishi

(日本:三菱)

Mitsubishi 300-500

Parameter Value

1

2

3

6

7

2

3

4

5

6

7

11

12

Mitsubish M50,60/60s,E60/68,M64/65/66

Parameter Value

9001

9002

9003

9004

9005

9101

9201

9102

9202

9103

9203

2

1

2

0

2

Out/In

Out/In

2

2

1

1

Comments

Input Port

Input Device

Out Port

Out device

Tape Mode

Baud rate 4800

1 Stop Bit

8 / 15

Comments

I/O Base parameters

1

1

0

0

200

2

3

0

1

3

3

3

1

I/O Devive parameters

I/O Base parameters

I/O Devive parameters

9104

9204

9105

9205

9106

9206

9108

9208

9109

9209

1

1

1

1

2

2

3

3

1

1

Use Parity = Yes

Parity = Even

7 Databits

Use xOnx/Off (DC1 and DC3)

Okuma

(日本:大隈)

Okuma 5000 / 7000

Parameter Value

1

34

39

44

45

46

54

57

Punch

Read

0

10

4800

0

0

0

1

90

Comments

number of spaces/ bytes of tape leader

Baud Rate

0000 1011 Optional parameter bits #1 (ISO Code)

1010 1010 Okuma 7000 Opt Para #8

1010 0010 Optional parameter bits #12 (Stop Bits/Parity)

Go to the 'Edit mode' [F3] (PIP), [F2] (Punch), type file name, then [Return]

Go to the 'Edit mode' [F3] (PIP), [F1] (Read), [Return]

Function

Yasnac

(日本:安川)

Yasnac LX MX

Parameter

6000

6001

6003

6021

6022

Value Comments

1xxx xxxx x = don't change

1xxx xxxx (Maybe only required on MX-2)

xxx1 xxx1

x111 xx1x (Maybe only required on LX/MX-1)

xxxx xx11

6026 / 6028

0001 1000 Baud rate - 2400

9 / 15

7 Data bits,Parity Even,2 Stop bits

Amada

(日本:天田)

Amada

Parameter

Baud Rate

Parity

Databits

Stop Bits

Dec Inp

Value

2400

Even

7

2

0

Comments

Also set these values in the DNC software

1=ISO (Do not use 0 EIA)

See cable diagrams below

Punch Code

1

Heidenhain

(德国:海德汉)

Heidenhain TNC 145

Parameter Value Comments

Baud

rate

Parity

Databits

2400

Even

7

In the DNC software select RTS/CTS flow control

DNC Software should insert STX and ETX codes into the transmit data -

For example with easyDnc 4.0 this is acheived in the DNC Setup window

by selecting 'Advanced' and select these options from the drop-lists.

ASCII Start Code = STX (02)

ASCII End Code = ETX (03)

Stop Bits

2

Heidenhain TNC 150

Parameter Value

MP92

MP71

1

3

Comments

Select Multi Func.

(Same as in the DNC software )

In the DNC software select RTS/CTS flow control

DNC Software should insert STX and ETX codes into the transmit data -

For example with easyDnc 4.7 this is acheived in the DNC Setup window

by selecting 'Advanced' and select these options from the drop-lists.

ASCII Start Code = STX (02)

ASCII End Code = ETX (03)

10 / 15

BaudRate

2400

Heidenhain TNC 155,355

Parameter Value Comments

MP232

MP71

MP222

0

515

104

in the DNC software Set Baud rate 2400 -7 DataBits -Even -2 StopBits

In the DNC software select RTS/CTS flow control

DNC Software should insert STX and ETX codes into the transmit data - For

example with easyDnc 4.0 this is acheived in the DNC Setup window by

selecting 'Advanced' and select these options from the drop-lists.

ASCII Start Code = STX (02)

ASCII End Code = ETX (03)

Heidenhain TNC 415,425

Parameter

Device

MP 5200.1

MP 5201.1

MP 5020.1

MP 5030.1

Value

2

3

104

0

Comments

in the DNC software Set Baud rate 2400 -7 DataBits -Even -2

StopBits

In the DNC software select RTS/CTS flow control

DNC Software should insert STX and ETX codes into the transmit

data - For example with easyDnc 4.0 this is acheived in the DNC Setup

window by selecting 'Advanced' and select these options from the

drop-lists.

ASCII Start Code = STX (02)

ASCII End Code = ETX (03)

EXT 2

Heidenhain TNC 2500

Parameter

MP 5020

MP 5030

Value

100

0

Comments

in the DNC software Set Baud rate 2400 -7 DataBits -Even -2

StopBits

In the DNC software select RTS/CTS flow control

DNC Software should insert STX and ETX codes into the transmit

data - For example with easyDnc 4.0 this is acheived in the DNC Setup

window by selecting 'Advanced' and select these options from the

drop-lists.

ASCII Start Code = STX (02)

11 / 15

ASCII End Code = ETX (03)

Hinumerik

(德国:)

Hinumerik 2000,2100 (M/T)

Parameter Value

5010

5012

5011

5013

5016

RTS

0

0

Comments

1100 0101 = 2400 For other Baud Rates see the table below

1100 0101 Same as 5011 - For other Baud Rates see the table below

xx10 xxxx

Line 1

In the DNC software select RTS/CTS flow control

1100 0101 = 2400,1100 0110 = 4800

x = do not change

Hinumerik 3000 ,3100 (M/T)

Parameter Value

411

412

416

Comments

1110 1101 = 2400 For other Baud Rates see the table below

1110 1101 Same as 5011 - For other Baud Rates see the table below

1xxx xxx1

1110 1101 = 2400,1110 1110 = 4800

x = do not change

In the DNC software select RTS/CTS flow control

Sinumerik

(德国:西门子)

Sinumerik 3M and 3T

Parameter Value

411

412

416

Comments

1110 1101 = Baud Rate 2400

1110 1101 See below for other baud rates

1xxxxxx1

1110 1101 = 2400,1110 1110 = 4800

x = Do not change

Sinumerik 8M and 8T

Parameter Value

428

429

425

430

461

Comments

1110 1101 = Baud Rate 2400

1110 1101 See below for other baud rates

xxxx x0xx

xx0x xxxx

1110 1101 = 2400,1110 1110 = 4800

x = Do not change

x = Do not change

0000 0000

12 / 15

Sinumerik 810and 850 (M/T)

Parameter Value

5010

5012

5011

5013

0

0

Comments

1111 0101 = Baud Rate 2400

1111 0101 See below for other baud rates

1111 0101 = 2400,1111 0110 = 4800

RTS Line

1

Sinumerik 840D

Parameter

Serial

Device

Device Type

Protocol

Baud rate

Stop bits 2

Parity

Bit/character

Xoff character

EOT

Leader

Ready

EOB

Format

Value

1

Standard/WS800A

Universal

RTS/CTS (Hardware)

9600

2

Even

7

13

03

No

No

CRLF

Punch tape format

Comments

Xon character

11

Time out in Sec.

60

Traub

(德国:特劳伯)

Traub TX8

Parameter

#1

01

04

#2

12

Value

0

1

0

5

Comments

Parity

ISO

Baud Rate = 1200

13 / 15

Fagor

(西班牙:发格)

Fagor 80xx

Parameter Value Comments

In the control settings select

9 (Special Modes)

1 (General Parameters)

P000

P001

P002

P003

Fagor 8025T

Parameter Value Comments

In the control settings select

9 (Special Modes)

1 (General Parameters)

P000

P001

P002

P003

P605

7

2

2

0001 0000

Valid Baud Rates 2400, 4800 (Same as the DNC Software)

7 Databits

Even Parity

Stop Bits

DNC activate

7

2

2

Valid Baud Rates 2400, 4800 (Same as the DNC Software)

7 Databits

Even Parity

Stop Bits

After making changes - reset the controller

After making changes - reset the controller

传输故障的解决

1. 检查 PC和 CNC 的端口参数设置是否一致,波特率速度设置不宜太快(太快可能会

丢失数据),也不宜太慢(速度慢当然效率就低了) ;

2. 连接电缆是否有断线,接触不良,焊接是否正确;

3. 通讯软件选择不对,有一些系统必须用原厂的通讯软件;

4. 传输的文件格式不正确;

5. 有较大干扰,选择优质屏蔽电缆做传输线;

6. 如果上述都正确,那就是端口损坏。

另外,曾经使用过数据传送,参数设置也正确的情况下,同样也会发生传送故障,这时

把PC的FIFO缓冲区取消或者使“接收缓冲区”与“传输缓冲区”为最低即可。

置方法如下:

打开PC“控制面板”—“系统”—“硬件”—“设备管理器”—“端口”—“通讯端

口”,右键,“属性”—“端口设置”—“高级”—“使用FIFO缓存”,使“接收缓冲区”与

14 / 15

“传输缓冲区”为最低即可,或者取消“使用FIFO缓存”。

15 / 15

发布评论

评论列表 (0)

  1. 暂无评论