14.3. Park Gantries [F4]
Moves the Gantries to the center of the Y axis, the parking position. While the Gantries
are parked, any kind of XY axis movement like Move or Home for XY Teaching is not
allowed.
14.4. Run Random [F5]
Randomly carries out motor control diagnosis. In this test, after setting a pickup position
and a placement position randomly, the motor is controlled while it is driven to the
respective positions. As the Z stroke is limited in this test, the objects on the Tabletop do
not cause interference. If another window is selected with the mouse(when this dialog
box is out of focus) during the execution of Run Random, the operation will stop.
Figure 14-4. “Run Random” dialog box
w
§
Check it to limit the motor movement within a narrow range.
§
Select Gantry.
§
To drive the selected motor, click this button
§
To stop driving of the selected motor, click this button.
w
To return all axes to their home positions, click this button.
w
To close this dialog box, click this button.
14-3
Samsung Component Placer CP-60L Operations Manual
Warning
Pressing the Start switch without checking the presence
of worker nearby could cause injury.
Be sure to check if there is any worker near the machine
before pressing the Start switch.
14.5. Index Board [F6]
Used to transfer a board from one Station to another Station on the Conveyor. When it is
executed, the following dialog box appears.
14.6. ByPass [F7]
Used to transfer PCBs without running the machine during In-Line operation.
w Board Flow
Displays the direction of PCB flow.
w DO-Busy / DI-Available
Displays the status of SMEMA signal connected to the previous machine.
w DI-Busy / DO-Available
Displays the status of SMEMA signal connected to the next machine.
w
14-4
2024年7月24日发(作者:税林)
Utility Menu
14.3. Park Gantries [F4]
Moves the Gantries to the center of the Y axis, the parking position. While the Gantries
are parked, any kind of XY axis movement like Move or Home for XY Teaching is not
allowed.
14.4. Run Random [F5]
Randomly carries out motor control diagnosis. In this test, after setting a pickup position
and a placement position randomly, the motor is controlled while it is driven to the
respective positions. As the Z stroke is limited in this test, the objects on the Tabletop do
not cause interference. If another window is selected with the mouse(when this dialog
box is out of focus) during the execution of Run Random, the operation will stop.
Figure 14-4. “Run Random” dialog box
w
§
Check it to limit the motor movement within a narrow range.
§
Select Gantry.
§
To drive the selected motor, click this button
§
To stop driving of the selected motor, click this button.
w
To return all axes to their home positions, click this button.
w
To close this dialog box, click this button.
14-3
Samsung Component Placer CP-60L Operations Manual
Warning
Pressing the Start switch without checking the presence
of worker nearby could cause injury.
Be sure to check if there is any worker near the machine
before pressing the Start switch.
14.5. Index Board [F6]
Used to transfer a board from one Station to another Station on the Conveyor. When it is
executed, the following dialog box appears.
14.6. ByPass [F7]
Used to transfer PCBs without running the machine during In-Line operation.
w Board Flow
Displays the direction of PCB flow.
w DO-Busy / DI-Available
Displays the status of SMEMA signal connected to the previous machine.
w DI-Busy / DO-Available
Displays the status of SMEMA signal connected to the next machine.
w