NPort 6450 Series
Quick Installation Guide
Version 11.2, January 2021
Technical Support Contact Information
/support
2021 Moxa Inc. All rights reserved.
P/N: 18
*18*
Overview
The NPort 6450 secure serial device servers provide reliable
serial-to-Ethernet connectivity for a wide range of serial devices. The
NPort 6450 supports TCP Server, TCP Client, UDP, and Pair-Connection
operation modes to ensure the compatibility of network software. In
addition, the NPort 6450 also supports Secure TCP Server, Secure TCP
Client, Secure Pair-Connection, and Secure Real COM modes for security
critical applications such as banking, telecom, access control, and remote
site management.
Package Checklist
Before installing the NPort 6450, please verify that the package contains
the following items:
•
•
•
•
•
•
•
•
•
•
•
•
NPort 6450
Power adapter (does not apply to T models)
Two wall-mount ears
Documentation
Quick installation guide
Warranty card
DK-35A: 35 mm DIN-rail mounting kit
DIN-rail power supply (DR-75-48)
CBL-RJ45M9-150: 8-pin RJ45 to male DB9 cable
CBL-RJ45M25-150: 8-pin RJ45 to male DB25 cable
NM-TX01: Network module with one 10/100BaseTX Ethernet port
(RJ45 connector; supports cascade redundancy and RSTP/STP)
NM-FX01-S-SC/NM-FX01-S-SC-T: Network module with one
100BaseFX single mode fiber port (SC connector; supports cascade
redundancy and RSTP/STP)
NM-FX02-S-SC/NM-FX02-S-SC-T: Network module with two
100BaseFX single mode fiber ports (SC connectors; supports cascade
redundancy and RSTP/STP)
NM-FX01-M-SC/NM-FX01-M-SC-T: Network module with one
100BaseFX multi-mode fiber port (SC connector; supports cascade
redundancy and RSTP/STP)
NM-FX02-M-SC/NM-FX02-M-SC-T: Network module with two
100BaseFX multi-mode fiber ports (SC connectors; supports cascade
redundancy and RSTP/STP)
Optional Accessories
•
•
•
NOTE Please notify your sales representative if any of the above items
are missing or damaged.
WARNING
The risk of an explosion exists if the battery is replaced by an
incorrect type. Dispose of used batteries according to the
instructions.
NOTE This is a Class 1 laser/LED product. Do not share directly into the
laser beam.
- 2 -
NOTE The installation instructions indicate use in a RESTRICTED
ACCESS LOCATION only.
Hardware Introduction
NOTE The LCD panel is only available with standard temperature
models.
Reset Button—Press the Reset button continuously for 5 sec to load
factory defaults. Use a pointed object, such as a straightened paper clip or
toothpick, to press the reset button. This will cause the Ready LED to blink
on and off. The factory defaults will be loaded once the Ready LED stops
blinking (after about 5 seconds). At this point, you should release the
reset button.
LED Indicators
Name
PWR
Ready
Color
Red
Red
Function
Power is being supplied to the power input.
Steady on: NPort is booting up.
Blinking: IP conflict, DHCP or BOOTP server
problem, or relay output problem.
Steady on: Power is on and the NPort 6450 is
functioning normally.
Blinking: NPort is responding to Locate
function.
Power is off, or power error condition exists.
10 Mbps Ethernet connection.
100 Mbps Ethernet connection.
Ethernet cable is disconnected, or has a short.
- 3 -
Green
Link
Off
Orange
Green
Off
Name
P1-P4
FX
Color
Orange
Green
Off
Orange
Alarm Red
Off
Green
Off
Module
Function
Serial port is receiving data.
Serial port is transmitting data.
Serial port is idle.
Steady on: Ethernet port is idle.
Blinking: Fiber port is transmitting or receiving
data.
The relay output (DOUT) is open (exception).
The relay output (DOUT) is shorted (normal
condition).
A network module has been detected.
No network module is present.
Adjustable pull up/down resistor for RS-422/485 (150
KΩ or 1 K
Ω)
Dip switch Pin 1 and Pin 2 are
used to set the pull up/down
resistors. The default is 150
KΩ. Turn on dip switch Pin 1
and Pin 2 to set this value to 1
KΩ. Do not use the KΩ setting
with RS-232 mode, since
doing so will degrade the
RS-232 signals and shorten
the communication distance.
Dip switch Pin 3 is used to set
the terminator. Turn on dip
switch Pin 3 to set this value to
120 ohm.
Hardware Installation Procedure
STEP 1: Connect the 12-48 VDC power adapter to the NPort 6450 and
then plug the power adapter into a DC outlet.
STEP 2: For first-time configuration, use a cross-over Ethernet cable to
connect the NPort 6450 directly to your computer’s Ethernet cable. For
connecting to a network, use a standard straight-through Ethernet cable
to connect to a hub or switch.
STEP 3: Connect the NPort 6450’s serial port(s) to serial device(s).
NOTE The operating temperature of the power adapter in the box is 0 to
40˚C. If your application is out of this range, please use a power
adapter supplied by UL Listed External Power Supply (The power
output meets SELV and LPS and rated 12 - 48 VDC, minimum
0.73A). Moxa has power adapters with wide temperature range
(-40 to 75˚C, -40 to 167˚F), the PWR-12150-(plug type)-SA-T
series, for your reference.
- 4 -
Placement Options
The NPort 6450 can be placed flat on a desktop or other horizontal surface.
In addition, you may use the DIN-Rail or wall-mount options, as
illustrated below.
Wall-mount DIN Rail
Software Installation Information
For the NPort’s configuration, the default IP address of the NPort is
192.168.127.254. You may log in with the account name admin and
password moxa to change any settings to meet your network topology
(e.g., IP address) or serial device (e.g., serial parameters).
For software installation, download the relative utilities from Moxa's
website:
/support/support_?isSearchShow=1
•
•
•
Download the NPort Windows Driver Manager and install it as the
driver to run with Real COM mode of the NPort Series.
Execute NPort Windows Driver Manager; then map the virtual COM
ports on your Windows platform.
You may refer to the DB9 Male pin assignment section to loop back
pin 2 and pin 3 for the RS-232 interface to carry out a self-test on the
device.
Use HyperTerminal or a similar program (you may download Moxa's
program, called PComm Lite) to test whether the device is good or
not.
•
Pin Assignments and Cable Wiring
RS-232/422/485 Pin Assignments (male DB9)
Pin
1
2
3
4
5
6
7
8
9
RS-232
DCD
RXD
TXD
DTR
GND
DSR
RTS
CTS
–
RS-422/
4W RS-485
TxD-(A)
TxD+(B)
RxD+(B)
RxD-(A)
GND
–
–
–
–
2W RS-485
–
–
Data+(B)
Data-(A)
GND
–
–
–
–
- 5 -
Japan Regulatory Compliance (VCCI)
The NPort 6000 series complies with the requirements of VCCI Class A
Information Technology Equipment (ITE).
WARNING
If this equipment is used in a domestic environment, radio
disturbance may arise. When such trouble occurs, the user may
be required to take corrective actions.
- 6 -
2024年9月11日发(作者:余若山)
NPort 6450 Series
Quick Installation Guide
Version 11.2, January 2021
Technical Support Contact Information
/support
2021 Moxa Inc. All rights reserved.
P/N: 18
*18*
Overview
The NPort 6450 secure serial device servers provide reliable
serial-to-Ethernet connectivity for a wide range of serial devices. The
NPort 6450 supports TCP Server, TCP Client, UDP, and Pair-Connection
operation modes to ensure the compatibility of network software. In
addition, the NPort 6450 also supports Secure TCP Server, Secure TCP
Client, Secure Pair-Connection, and Secure Real COM modes for security
critical applications such as banking, telecom, access control, and remote
site management.
Package Checklist
Before installing the NPort 6450, please verify that the package contains
the following items:
•
•
•
•
•
•
•
•
•
•
•
•
NPort 6450
Power adapter (does not apply to T models)
Two wall-mount ears
Documentation
Quick installation guide
Warranty card
DK-35A: 35 mm DIN-rail mounting kit
DIN-rail power supply (DR-75-48)
CBL-RJ45M9-150: 8-pin RJ45 to male DB9 cable
CBL-RJ45M25-150: 8-pin RJ45 to male DB25 cable
NM-TX01: Network module with one 10/100BaseTX Ethernet port
(RJ45 connector; supports cascade redundancy and RSTP/STP)
NM-FX01-S-SC/NM-FX01-S-SC-T: Network module with one
100BaseFX single mode fiber port (SC connector; supports cascade
redundancy and RSTP/STP)
NM-FX02-S-SC/NM-FX02-S-SC-T: Network module with two
100BaseFX single mode fiber ports (SC connectors; supports cascade
redundancy and RSTP/STP)
NM-FX01-M-SC/NM-FX01-M-SC-T: Network module with one
100BaseFX multi-mode fiber port (SC connector; supports cascade
redundancy and RSTP/STP)
NM-FX02-M-SC/NM-FX02-M-SC-T: Network module with two
100BaseFX multi-mode fiber ports (SC connectors; supports cascade
redundancy and RSTP/STP)
Optional Accessories
•
•
•
NOTE Please notify your sales representative if any of the above items
are missing or damaged.
WARNING
The risk of an explosion exists if the battery is replaced by an
incorrect type. Dispose of used batteries according to the
instructions.
NOTE This is a Class 1 laser/LED product. Do not share directly into the
laser beam.
- 2 -
NOTE The installation instructions indicate use in a RESTRICTED
ACCESS LOCATION only.
Hardware Introduction
NOTE The LCD panel is only available with standard temperature
models.
Reset Button—Press the Reset button continuously for 5 sec to load
factory defaults. Use a pointed object, such as a straightened paper clip or
toothpick, to press the reset button. This will cause the Ready LED to blink
on and off. The factory defaults will be loaded once the Ready LED stops
blinking (after about 5 seconds). At this point, you should release the
reset button.
LED Indicators
Name
PWR
Ready
Color
Red
Red
Function
Power is being supplied to the power input.
Steady on: NPort is booting up.
Blinking: IP conflict, DHCP or BOOTP server
problem, or relay output problem.
Steady on: Power is on and the NPort 6450 is
functioning normally.
Blinking: NPort is responding to Locate
function.
Power is off, or power error condition exists.
10 Mbps Ethernet connection.
100 Mbps Ethernet connection.
Ethernet cable is disconnected, or has a short.
- 3 -
Green
Link
Off
Orange
Green
Off
Name
P1-P4
FX
Color
Orange
Green
Off
Orange
Alarm Red
Off
Green
Off
Module
Function
Serial port is receiving data.
Serial port is transmitting data.
Serial port is idle.
Steady on: Ethernet port is idle.
Blinking: Fiber port is transmitting or receiving
data.
The relay output (DOUT) is open (exception).
The relay output (DOUT) is shorted (normal
condition).
A network module has been detected.
No network module is present.
Adjustable pull up/down resistor for RS-422/485 (150
KΩ or 1 K
Ω)
Dip switch Pin 1 and Pin 2 are
used to set the pull up/down
resistors. The default is 150
KΩ. Turn on dip switch Pin 1
and Pin 2 to set this value to 1
KΩ. Do not use the KΩ setting
with RS-232 mode, since
doing so will degrade the
RS-232 signals and shorten
the communication distance.
Dip switch Pin 3 is used to set
the terminator. Turn on dip
switch Pin 3 to set this value to
120 ohm.
Hardware Installation Procedure
STEP 1: Connect the 12-48 VDC power adapter to the NPort 6450 and
then plug the power adapter into a DC outlet.
STEP 2: For first-time configuration, use a cross-over Ethernet cable to
connect the NPort 6450 directly to your computer’s Ethernet cable. For
connecting to a network, use a standard straight-through Ethernet cable
to connect to a hub or switch.
STEP 3: Connect the NPort 6450’s serial port(s) to serial device(s).
NOTE The operating temperature of the power adapter in the box is 0 to
40˚C. If your application is out of this range, please use a power
adapter supplied by UL Listed External Power Supply (The power
output meets SELV and LPS and rated 12 - 48 VDC, minimum
0.73A). Moxa has power adapters with wide temperature range
(-40 to 75˚C, -40 to 167˚F), the PWR-12150-(plug type)-SA-T
series, for your reference.
- 4 -
Placement Options
The NPort 6450 can be placed flat on a desktop or other horizontal surface.
In addition, you may use the DIN-Rail or wall-mount options, as
illustrated below.
Wall-mount DIN Rail
Software Installation Information
For the NPort’s configuration, the default IP address of the NPort is
192.168.127.254. You may log in with the account name admin and
password moxa to change any settings to meet your network topology
(e.g., IP address) or serial device (e.g., serial parameters).
For software installation, download the relative utilities from Moxa's
website:
/support/support_?isSearchShow=1
•
•
•
Download the NPort Windows Driver Manager and install it as the
driver to run with Real COM mode of the NPort Series.
Execute NPort Windows Driver Manager; then map the virtual COM
ports on your Windows platform.
You may refer to the DB9 Male pin assignment section to loop back
pin 2 and pin 3 for the RS-232 interface to carry out a self-test on the
device.
Use HyperTerminal or a similar program (you may download Moxa's
program, called PComm Lite) to test whether the device is good or
not.
•
Pin Assignments and Cable Wiring
RS-232/422/485 Pin Assignments (male DB9)
Pin
1
2
3
4
5
6
7
8
9
RS-232
DCD
RXD
TXD
DTR
GND
DSR
RTS
CTS
–
RS-422/
4W RS-485
TxD-(A)
TxD+(B)
RxD+(B)
RxD-(A)
GND
–
–
–
–
2W RS-485
–
–
Data+(B)
Data-(A)
GND
–
–
–
–
- 5 -
Japan Regulatory Compliance (VCCI)
The NPort 6000 series complies with the requirements of VCCI Class A
Information Technology Equipment (ITE).
WARNING
If this equipment is used in a domestic environment, radio
disturbance may arise. When such trouble occurs, the user may
be required to take corrective actions.
- 6 -