Instructions for a Firmware Update of SINAMICS S210

SINAMICS S210

SINAMICS S210 Firmware Update Instructions

You have got the possibility to upgrade the converter to a new firmware version. You can also downgrade

the converter to a previous firmware version, in order to deliver the machine with a constant firmware

version.

When upgrading the firmware the previous settings will be maintained.

When downgrading to a previous firmware the converter is reset to factory defaults.

Hardware Prerequisites

This description is valid for the following article numbers:

Main supply

1AC 230V

1AC 230V

1AC 230V

1AC 230V

3AC 400V

3AC 400V

3AC 400V

Power

100 W

200 W

400 W

750 W

400 W

750 W

1 kW

S210 article number

6SL3210-5HB10-1UF0

6SL3210-5HB10-2UF0

6SL3210-5HB10-4UF0

6SL3210-5HB10-8UF0

6SL3210-5HE10-4UF0

6SL3210-5HE10-8UF0

6SL3210-5HE11-0UF0

as of Version Frame size

V5.1FSA

V5.1FSA

V5.1FSB

V5.1FSB

V5.2FSA

V5.2FSA

V5.2FSA

These1AC 230V converters support the SINAMICS Runtime firmware as of versionV5.1.

These3AC 400VFSA converters support the SINAMICS Runtime firmware as of versionV5.2.

1 / 3

s

Instructions for a Firmware Update of SINAMICS S210

Memory cards for the Firmware Update

SINAMICS S210

A SD-memory card is required for the firmware update.

Either you can use a memory card which is already plugged into the converter or a new memory card.

Alternatively you can order a memory card with software on which the desired firmware is already installed.

Card type

Empty SD-Card

SD-Card with Firmware V5.1

SD-Card with Firmware V5.1 SP1

SD-Card with Firmware V5.1 SP1

with Extended Safety License

SD-Card with Firmware V5.2

SD-Card with Firmware V5.2

with Extended Safety License

Article number

6SL3054-4AG00-2AA0

6SL3054-4FB00-2BA0

6SL3054-4FB10-2BA0

6SL3054-4FB10-2BA0-Z F01

6SL3054-4FC00-2BA0

6SL3054-4FC00-2BA0-Z F01

These SD-Cards can also be used to store the licenses for functions which require licensing. (e. g. Extended

Safety License). It is not possible to use standard SD-card for this purpose.

Note

The integrated card reader only supports SD-cards up to a memory capacity of 2 GB.

SDHC- or SDXC-cards are not supported.

Preparing the SD-card for the Firmware Update

In order to install the software on the SD-card a SD-card reader is required in the PC/PG.

If you are using a SD-card with preinstalled firmware then you can directly proceed with the firmware update.

Backup of the SD-card

If you like to install software on a SD-card which is already plugged into the converter, then switch the

converter off and eject the SD-card.

Before installing new software on this SD-card it is absolutely necessary to save all directories/files of the

SD-card on your PC/PG. This especially applies to the installed licenses (directory KEYS, if available).

Preparing the SD-card

After backing up the SD-card content on the PC/PG you can delete all files from the memory card (if a

directory KEYS exists it does not need to be deleted).

Extract the ZIP-file with the firmware which you like to install onto the SD-card.

Copy the directory KEYS from the backup on your PC/PG back onto the SD-card (in case the directory

KEYS was available and has been deleted before).

2 / 3

s

Instructions for a Firmware Update of SINAMICS S210

Firmware Update

SINAMICS S210

Attention:

Please do not turn off the power supply of the converter during the update process and do not disconnect the

motor (if it is connected)!

Doing so could lead to faulty components.

Please proceed as follows to perform a Firmware-Upgrade or –Downgrade:

1. Switch the converter off.

2. Insert the prepared SD-card into the converter and turn the converter on.

3. The new firmware will be installed – this can take up to 5 minutes and more.

The update has finished when both LEDs are blinking red synchronously every second.

4. Switch the converter off and remove the memory card as needed.

5. Switch the converter back on. The firmware of the connected DriveCliq-components will be updated.

This requires and additional power off/on (RDY-LED is blinking fast in yellow; refer to alarm

messages in the webserver).

6. Verify that the new firmware version was installed correctly. The firmware version is displayed on the

Home page of the webserver below the converter symbol.

7. Commission the converter if necessary.

8. In case the memory card shall remain plugged into the converter, save the parameters in the

webserver so that the actual configuration is stored on the memory card as well.

Extract LED-States

Please find further information concerning the LED states in the manual.

Interesting Links:

SINAMICS S210 Firmware

/cs/de/en/view/109744577

SINAMICS S210 PROFINET GSDML

/cs/de/en/view/109752524

3 / 3

2024年9月19日发(作者:通梓莹)

s

Instructions for a Firmware Update of SINAMICS S210

SINAMICS S210

SINAMICS S210 Firmware Update Instructions

You have got the possibility to upgrade the converter to a new firmware version. You can also downgrade

the converter to a previous firmware version, in order to deliver the machine with a constant firmware

version.

When upgrading the firmware the previous settings will be maintained.

When downgrading to a previous firmware the converter is reset to factory defaults.

Hardware Prerequisites

This description is valid for the following article numbers:

Main supply

1AC 230V

1AC 230V

1AC 230V

1AC 230V

3AC 400V

3AC 400V

3AC 400V

Power

100 W

200 W

400 W

750 W

400 W

750 W

1 kW

S210 article number

6SL3210-5HB10-1UF0

6SL3210-5HB10-2UF0

6SL3210-5HB10-4UF0

6SL3210-5HB10-8UF0

6SL3210-5HE10-4UF0

6SL3210-5HE10-8UF0

6SL3210-5HE11-0UF0

as of Version Frame size

V5.1FSA

V5.1FSA

V5.1FSB

V5.1FSB

V5.2FSA

V5.2FSA

V5.2FSA

These1AC 230V converters support the SINAMICS Runtime firmware as of versionV5.1.

These3AC 400VFSA converters support the SINAMICS Runtime firmware as of versionV5.2.

1 / 3

s

Instructions for a Firmware Update of SINAMICS S210

Memory cards for the Firmware Update

SINAMICS S210

A SD-memory card is required for the firmware update.

Either you can use a memory card which is already plugged into the converter or a new memory card.

Alternatively you can order a memory card with software on which the desired firmware is already installed.

Card type

Empty SD-Card

SD-Card with Firmware V5.1

SD-Card with Firmware V5.1 SP1

SD-Card with Firmware V5.1 SP1

with Extended Safety License

SD-Card with Firmware V5.2

SD-Card with Firmware V5.2

with Extended Safety License

Article number

6SL3054-4AG00-2AA0

6SL3054-4FB00-2BA0

6SL3054-4FB10-2BA0

6SL3054-4FB10-2BA0-Z F01

6SL3054-4FC00-2BA0

6SL3054-4FC00-2BA0-Z F01

These SD-Cards can also be used to store the licenses for functions which require licensing. (e. g. Extended

Safety License). It is not possible to use standard SD-card for this purpose.

Note

The integrated card reader only supports SD-cards up to a memory capacity of 2 GB.

SDHC- or SDXC-cards are not supported.

Preparing the SD-card for the Firmware Update

In order to install the software on the SD-card a SD-card reader is required in the PC/PG.

If you are using a SD-card with preinstalled firmware then you can directly proceed with the firmware update.

Backup of the SD-card

If you like to install software on a SD-card which is already plugged into the converter, then switch the

converter off and eject the SD-card.

Before installing new software on this SD-card it is absolutely necessary to save all directories/files of the

SD-card on your PC/PG. This especially applies to the installed licenses (directory KEYS, if available).

Preparing the SD-card

After backing up the SD-card content on the PC/PG you can delete all files from the memory card (if a

directory KEYS exists it does not need to be deleted).

Extract the ZIP-file with the firmware which you like to install onto the SD-card.

Copy the directory KEYS from the backup on your PC/PG back onto the SD-card (in case the directory

KEYS was available and has been deleted before).

2 / 3

s

Instructions for a Firmware Update of SINAMICS S210

Firmware Update

SINAMICS S210

Attention:

Please do not turn off the power supply of the converter during the update process and do not disconnect the

motor (if it is connected)!

Doing so could lead to faulty components.

Please proceed as follows to perform a Firmware-Upgrade or –Downgrade:

1. Switch the converter off.

2. Insert the prepared SD-card into the converter and turn the converter on.

3. The new firmware will be installed – this can take up to 5 minutes and more.

The update has finished when both LEDs are blinking red synchronously every second.

4. Switch the converter off and remove the memory card as needed.

5. Switch the converter back on. The firmware of the connected DriveCliq-components will be updated.

This requires and additional power off/on (RDY-LED is blinking fast in yellow; refer to alarm

messages in the webserver).

6. Verify that the new firmware version was installed correctly. The firmware version is displayed on the

Home page of the webserver below the converter symbol.

7. Commission the converter if necessary.

8. In case the memory card shall remain plugged into the converter, save the parameters in the

webserver so that the actual configuration is stored on the memory card as well.

Extract LED-States

Please find further information concerning the LED states in the manual.