最新消息: USBMI致力于为网友们分享Windows、安卓、IOS等主流手机系统相关的资讯以及评测、同时提供相关教程、应用、软件下载等服务。

华硕PRIMERGY TX2550 M7 台式机或4U 机柜服务器说明书

IT圈 admin 31浏览 0评论

2024年9月26日发(作者:梁丘芸芸)

PRIMERGY TX2550 M7

Tower or 4U Rack server

ChapterFolder

Cover

Description

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

Base

CPU

RAM

GFX

HD_cage

RAID

ODD

Backup

HD_SSD

LAN

FC_IB

PCI_riser_card

PSU

USB_devices

Energy Star

ErP Lot9

others

Thermal

Content

List of content, Instructions for usage of this configurator,

abbreviations

System Description for easier understanding

Describes base units of TX2550 M7

Describes rack mount kits and services

Order codes, information Xeon processors

DDR5 System memory (RAM) and memory modes

Graphics-, Grid-cards, GPU and Xeon Co processors

HDD cage kits

SAS / RAID Controller and components

Optical disk drives (DVD, DVD-rw, Blu ray)

LTO drives & RDX drive

Storage drives - PCIe SSD - SAS/SATA SSD & HDD

LAN Components

Fibre Channel Controller

Infiniband Controller

PCI Riser

Power supply units, power cables, country specifics

Keyboards, Mice, USB devices

Energy Star limitation

Erp Lot9 limitation

System Management, ATD, RS232 port, TPM module

Thermal Rule

Instructions

This document contains basic product and configuration information that supports you in more complicated configurations.

In any case we recommend to use the WebArchitect to make sure, that you configure a valid system.

This System configurator is divided into several chapters. They are identical to the current price list and WebArchitect.

Please follow this document step by step from the top to the bottom

Chapter xx - description of chapter

Text fields with grey color offer extra information for related topics (e.g prerequesites, technical back

ground, configuration rules, limitations, …

S26361-F4610-E2

S26361-F4610-L3

PLAN 2x1Gb Ethern. Controller

i350-T2 chip (based on Intel Powerville) offers

2x1Gb RJ45 connectors

PCIe Gen2 x4 full height card

max. 6x per system

<-- order code E-part (bold) --

<-- order code L-part (bold)

<-- "name" of this part

<--description of this part, in same cases as well description of content

<--requires a free PCIe slot --> means total amount of PCIe slots reduced

<--indicates how often this part can be configured in the related Server

New order code

PYBVAP05

PY-VAP05

Front VGA connector (15-pin)

Front VGA connector (15-pin) including cable

and front connector

Not for 12x3.5", 24x2.5", 64xEDSFF base unit.

max. 1x per system

<-- "PYB" order code (bold) for BTO(Built to Order) part

<-- "PY-" order code (bold) for Loose delivery part

<-- "name" of this part

<--description of this part, in same cases as well description of content

<-- Limitation for this part

<--indicates how many this part can be configured in the related Server

For further information see:

Link to datasheet:

/dmsp/Publications/public/

/products/standard_servers/

(internet)

/com/order-supply/configurators/primergy_config/Pages/

(extranet)

Fujitsu is providing the content of this document with very high accuracy. In case you identify a mistake, we would kindly encourage you to inform us.

We kindly ask for understanding, that errors still may occur and that Fujitsu may change this document without notice

Abbreviations

SAS

SATA

HDD

SSD

SFF

LFF

CPU

RAID

Spaces

vSAN

storage tiering

hot data

cold data

ODD

OS

E-Part

L-Part

Drives, RAID

Drives, RAID

Drives

Drives

Drives

Drives

Processor

Drives, RAID

OS

OS

RAID

Drives

Drives

Drives

operating system

"Einbau-Part"

"Lose Lieferung-Part"

Serial attached SCSI Device (HDD, SSD, LTO drives); SAS2.0 = 6GBit/s; SAS3.0 = 12GBit/s

Serial ATA (HDD, SSD) current SATA speed = 6GBit/s

Hard disk drive (Non volatile storage device), 2.5" (SFF) or 3.5" (LFF)

Solid state disk (Non volatile storage device), 2.5" (SFF)

small form factor (=2.5")

large form factor (=3.5")

central processing unit ("processor")

RAID 0 = max speed, RAID 1 = mirroring, RAID 5 = 1 out of x drives is spare

Microsoft spaces, optimized in Win2012 R2 offers software RAID and storage tiering

offers optimized storage allocation (fast area for "hot data"; slower area for "cold data")

Data which are currently being processed

Data which are currently not processed (only stored)

optical disk drive (i.e. DVD-player, DVD-burner, Blu ray player, blu ray burner)

OS=operating system - required for running, organize and administrating the server

"e.g. S26361-F1234-E240" ordercode with "E" means it is either integrated into to Server (CPU, Mem, ..) or integrated in the

shipping box /Keyboard, Mouse, ..)

"e.g. S26361-F1234-L240" ordercode with "L" means, the part will be shipped with extra package, may be as well with extra

shipment

PRIMERGY TX2550 M7

System configurator and

order information guide

PCI Riser left (CPU2)

PCI Riser right (CPU1)

PRIMERGY TX2550 M7 rear view

cnfgTX2550M7-20231117_scriptionPage 4 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

PRIMERGY TX2550 M7 front view with drives

The front views shown below represent all possible drive options; they do not represent the base units.

For information on base units and HD drive cage for each drive option, please see chapter “base” and "HD_cage"

3.5-inch hot plug SAS/SATA

4x HDDs/SSDs8x HDDs/SSDs12x HDDs/SSDs

2.5-inch hot plug SAS/SATA/NVMe

8x HDDs/SSDs16x HDDs/SSDs16x HDDs/SSDs + 8xHDDs/SSDs/NVMes

24x HDDs/SSDs24x HDDs/SSDs + 8xHDDs/SSDs/NVMes

recommended components for TX2550 M7

Independant Mode installation

iRMC S6 advanced pack

Modular PSU 900W Titanium hot plug

#

1x

1x

2x

cnfgTX2550M7-20231117_scriptionPage 5 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

Chapter 1 - base unit

Start

Power supply units & cooling:

PRIMERGY TX2550 M7 offers bays for 2x (1x optional hot plug redundant) power supply units of 500W, 900W, 1600W, 2400W with up to 96% efficiency. 2200W with up to 94%

efficiency. Rack options ex factory or via retrofit upgrade with rack conversion kit.

Server Management:

iRMC S6 (integrated Remote Management Controller) on-board with dedicated Service LAN-port and integrated graphics controller. With onboard indicators and controls to easily

highlight failed components via LEDs displayed during service even without mains connection by simply pressing

the "indicate CSS" button. Optional ServerView Suite software incl. ServerView Installation Manager, Server View Remote Management and tools.

Platform:

Fujitsu Systemboard D3985-A made in Taiwan based on Chipset Intel® C741, up to two Xeon (Sapphire Rapids) series CPUs, four Intel® UltraPath

Interconnect (Intel® UPI) point-to-point links and onboard RAID 0/1 6Gbit/s available for up to 8x SATA drives.

16GB SD card as default

Slots: 6x PCIe slots are on board, with optional riser card up to 10x PCIe slots are available:

> 6x PCIe slots onboard, low profile, 167mm lengh, supported with first/second CPU:

Slot 1: PCIe-Gen5 x16

Slot 2: PCIe-Gen5 x16 (occupied in configurations with optional riser card)

Slot 3: PCIe-Gen5 x16 (occupied in configurations with optional riser card)

Slot 8: PCIe-Gen5 x16

Slot 9: PCIe-Gen5 x16 (occupied in configurations with optional riser card)

Slot 10: PCIe-Gen5 x16 (occupied in configurations with optional riser card)

> Optional full height riser card on PCIe slot 2/3/9/10 offers 4x additional PCIe slots, full height, 252mm and 1x PCI4/5 , with first/second CPU:

Slot 4/11: PCIe-Gen4/5 x16

Slot 5/12: PCIe-Gen4/5 x16

> Optional full height riser card on PCIe slot 2/3/9/10 offers 8x additional PCIe slots, full height, 252mm and 1x PCI4/5, with first/second CPU:

Slot 4/11: PCIe-Gen4/5 x8

Slot 5/12: PCIe-Gen4/5 x8

Slot 6/13: PCIe-Gen4/5 x8

Slot 7/14: PCIe-Gen4/5 x8

System RAM:

16x slots for DDR5-4800MHz RAM modules available (8x RAM modules per CPU). Memory speed depends on CPU and configuration.

LAN: 2x 1Gb LAN onboard;

Interfaces at rear sideInterfaces at front side

- 1x optional RS-232-C (serial port, 9 pin)- 2x USB 3.1 Gen1 (no USB wakeup)

- 2x LAN Rj45 (additional 2x RJ45 optionally available)

Interfaces internal

- 1x service LAN RJ45 (1 Gbit)

- 1x USB 3.1 Gen1 for backup devices

- 1x VGA (15 pins)

- 2x M.2

- 4x USB 3.1 Gen1

- 1x connector for TPM, 1x microSD card slot

Tower base units;

-Low noise hotplug fans

-up to 6 PCIe slots

Tower base units;

-High performance hotplug fans

-up to 10 PCIe slots

Rack base units;

-High performance hotplug fans

-up to 10 PCIe slots

C

h

o

o

s

e

o

n

e

b

a

s

e

u

n

i

t

PY TX2550 M7 Tower, 4x3.5" basic

PYT2557T3N

Tower server, expandable to 8x3.5";

Not support GPGPU

PY TX2550 M7 Tower, 8x3.5"

PYT2557TAN

Tower server, expandable to 12x3.5";

PY TX2550 M7 Rack, 8x3.5"

PYT2557R3N

Rack server, expandable to 12x3.5";

PY TX2550 M7 Tower, 8x2.5" basic

PYT2557T2N

Tower server, not expandable;

Not support GPGPU

PY TX2550 M7 Tower, 8x2.5"

PYT2557TBN

Tower server, expandable to 24x2.5";

PY TX2550 M7 Rack, 8x2.5"

PYT2557R2N

Rack server, expandable to 24x2.5";

PY TX2550 M7 Tower 4x3.5' basic and PY

TX2550 M7 Tower 8x2.5' basic do not support

Advanced Thermal design(ATD) options!

PY TX2550 M7 Tower, 24x2.5"

PYT2557TCN

Tower server, expandable to 32x2.5";

PY TX2550 M7 Rack, 24x2.5"

PYT2557RAN

Rack server, expandable to 32x2.5";

APRIMECENTER Rack

cnfgTX2550M7-20231117_sePage 6 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

Chapter 2 - Rack architecture

APRIMECENTER Rack

S26361-F2735-E111 PYBRRL6PY-RC18

No Rackmount-KitPY-RRL6

Rack conversion kit

No rackmount. Upgrade later possible

Rack Mount Kit F2-C S7 LV

Contains all necessary parts to convert PRIMERGY TX2550

with L-part

telescopic drop-in rail, full extractical, supports 1-

M7 Tower Server into a Rack server.

max. 1x per system

hand-mounting

Rackmount Kit ex factory

Rack mounting kit has to be ordered seperately.

> 1 pair of vario carrier with variable length & quick

release lever support

> 1 pair of telescopic drop-in rails with Cable

Management Arm (CMA) adapter

1x per system

S26361-F2735-E82

S26361-F2735-L82

2U cable management arm (CMA) for

2U server or higher

for mounting in symmetrical

PRIMECENTER M2/M1 racks

- 1 bracket PC M2/M1 Rack

1x per system

S26361-F1647-E302

Installation ex factory in a PRIMECENTER Rack

The installation service is to be ordered once per installable server/storage

Fujitsu will deliver the PRIMERGY mounted in a Rack System and all wired

subsystem, in order to get the server/storage subsystem mounted into the

connections are tested with PRIMECENTER rack - Systems and components will be

racks. In case of the 46 U PCR S2 this service has to be ordered, to get the

delivered installed in the rack

mounting kits and the cables installed.

max. 1x per System

B

cnfgTX2550M7-20231117_sePage 7 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

Chapter 3 - CPU

B

General Discription

There are 2 processor sockets available. Please configure 1 or 2 Processors.

>> All processors have to be the same type.

>> With one processor iRMC, 3x PCIe low profile slots(Up to 1x PCIe low profile + 4x PCIe full height) and 8x DIMM slots are available

>> With two processors all 16x DIMM slots, 6x PCIe low profile slots are available. Up to 2x PCIe low profile + 8x PCIe full height.

>> To configure 2nd CPU an additional cooler kit is required.

* HT = Hyper Threading

Notice

** Base Unit is not including CPUs. Minimum 1x CPU is required to be configured in one base unit.

** Maximum 2x CPUs are allowed to be configured in one base unit. Only 1 type of CPU can be configured in one base unit.

**CPU: PYBCP65XR, PYBCP65XS and PYBCP65X1 are not allowed to be configured 2x CPUs

CPU Group for

Thermal condition

Xeon Bronze 34xx - Mainline, 1 socket configuration only(BTO)(Loose delivery)

64-bit Intel Xeon processor supporting HT*, DDR5 @ 4000 MT/s

Xeon Bronze 3408U 8C 1.8GHz 125WPYBCP65XR-A

MCC

Xeon Silver 44xx - Mainline, 2 socket scalability(BTO)(Loose delivery)

64-bit Intel Xeon processor supporting HT*, DDR5 @ 4000 MT/s & UPI Bus (2UPI) @ 16 GT/s

Xeon Silver 4410Y 12C 2.0GHz 150W Speed Select TechnologyPYBCP66XGPY-CP66XGA

MCC

Xeon Silver 4416+ 20C 2.0GHz 165WPYBCP66XHPY-CP66XHB

MCC

Xeon Gold 54xx - Mainline/Performance Optimized, 1 socket configuration only(BTO)(Loose delivery)

64-bit Intel Xeon processor supporting HT*, DDR5 @ 4400 MT/s

Xeon Gold 5412U 24C 2.1GHz 185WPYBCP65XS-B

MCC

Xeon Gold 54xx - Mainline/Performance Optimized, 2 socket scalablity(BTO)(Loose delivery)

64-bit Intel Xeon processor supporting HT*, DDR5 @ 4400 MT/s & UPI Bus (3UPI) @ 16 GT/s

Xeon Gold 5415+ 8C 2.9GHz 150WPYBCP65XTPY-CP65XTA

MCC

Xeon Gold 5418Y 24C 2.0GHz 185W Speed Select TechnologyPYBCP65XWPY-CP65XWB

MCC

Xeon Gold 5420+ 28C 2.0GHz 205WPYBCP65XXPY-CP65XXB

MCC

Xeon Gold 64xx - Mainline/Performance Optimized, 1 socket configuration only(BTO)(Loose delivery)

64-bit Intel Xeon processor supporting HT*, DDR5 @ 4800(1DPC) / 4400(2DPC) MT/s

Xeon Gold 6414U 32C 2.0GHz 250WPYBCP65X1-C

XCC

Xeon Gold 64xx - Mainline/Performance Optimized, 2 socket scalability(BTO)(Loose delivery)

64-bit Intel Xeon processor supporting HT*, DDR5 @ 4800(1DPC) / 4400(2DPC) MT/s & UPI Bus (3UPI) @ 16 GT/s

Xeon Gold 6426Y 16C 2.5GHz 185W Speed Select TechnologyPYBCP66X2PY-CP66X2B

MCC

Xeon Gold 6430 32C 2.1GHz 270W (DDR5 @ 4400(1DPC/2DPC)) PYBCP65X2PY-CP65X2D

XCC

Xeon Gold 6434 8C 3.7GHz 195WPYBCP66X4PY-CP66X4B

MCC

Xeon Gold 6438Y+ 32C 2.0GHz 205W Speed Select TechnologyPYBCP66X8PY-CP66X8B

MCC

Xeon Gold 6442Y 24C 2.6GHz 225W Speed Select TechnologyPYBCP66X9PY-CP66X9C

MCC

Xeon Gold 6448Y 32C 2.1GHz 225W Speed Select TechnologyPYBCP66XCPY-CP66XCC

MCC

Xeon Platinum 84xxH - IMDB/Analytics Workload Optimized, 8 socket scalability(BTO)(Loose delivery)

64-bit Intel Xeon processor supporting HT*, DDR5 @ 4800(1DPC) / 4400(2DPC) MT/s & UPI Bus (4UPI) @ 16 GT/s

Xeon Platinum 8444H 16C 2.9GHz 270WPYBCP65X4PY-CP65X4D

XCC

Xeon Platinum 8450H 28C 2.0GHz 250W Speed Select TechnologyPYBCP65X6PY-CP65X6C

XCC

Xeon - Storage & HCI Workload Optimized, 2 socket scalability(BTO)(Loose delivery)

64-bit Intel Xeon processor supporting HT*, DDR5 @ 4800(1DPC) / 4400(2DPC) MT/s & UPI Bus (3UPI) @ 16 GT/s

Xeon Gold 5416S 16C 2.0GHz 150W (DDR5 @ 4400(1DPC/2DPC)) Speed Select TechnoPYBCP65XUPY-CP65XUA

MCC

Xeon Gold 6454S 32C 2.2GHz 270W Speed Select TechnologyPYBCP65X3PY-CP65X3D

XCC

Xeon - Long-Life Use (IOT) Workload Optimized, 2 socket scalability(BTO)(Loose delivery)

64-bit Intel Xeon processor supporting HT*, DDR5 @ 4000 MT/s & UPI Bus (2UPI) @ 16 GT/s

Xeon Silver 4410T 10C 2.7GHz 150W Speed Select TechnologyPYBCP66XFPY-CP66XFA

MCC

Notice

2CPU configuration require to order 2nd CPU cooler kit

CPU Cooler kit(BTO)(Loose delivery)

2nd CPU Cooler kit for Basic model***PYBTKCPC85-

2nd CPU Cooler kit****PYBTKCPC86-

CPU cooler kit for loose delivery CPU for Basic model***-PY-TKCPC85

CPU cooler kit for loose delivery CPU****-PY-TKCPC86

*** For PYT2557T3N/PYT2557T2N

**** For PYT2557TAN/PYT2557TBN/PYT2557TCN/PYT2557R3N/PYT2557R2N/PYT2557RAN

C

cnfgTX2550M7-20231117_UPage 8 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

Chapter 4 - DDR5 System memory

C

Each CPU offers 8 Slots for DDR5 Memory Modules organised in 1 Banks and 8 Channels with 4 Memory Controllers (2 Channels each).

If you need more than 8 Slots you have to configure 2nd CPU.

Depending on the amount of memory configured you can decide between the Normal Memory RAS mode or the Mirroring Memory RAS Mode.

There are different kinds of DDR5 Memory Modules available: RDIMM x4, RDIMM x8, RDIMM 3DS x4.

Mix of different memories is not allowed.

Supported memory capacities per CPU:

Up to 2TB using DDR5 RDIMM (8x 256GB DDR5 RDIMM 3DS)

Supported memory capacities per System (with 2CPU configuration):

Up to 4TB using DDR5 RDIMM (16x 256GB DDR5 RDIMM 3DS)

The memory speed depends on configuration restricted by the CPU SKU (max. 4800 MT/s).

DDR5 memory is operated at 1.1V

Memory Mode ; One of followig memory modes must be selected.

Independent ModeRequires 1, 2, 4, 6 or 8 Memory Modules per CPU1x per CPUPYBMMD2

Independent Mode required to be the best performance.

ADDDC Sparing is available in case system configured by DDR5 xRx4 DIMM only.

Mirroring ModeRequires 8 Memory Modules per CPU1x per CPUPYBMMC4

BIOS preconfiguration for Mirroring mode. 8x identical memory modules are always equipped on same bank across all channels to use the mirrored channel mode. Half of the

modules contain active data, the remaining modules contain mirrored data.

min/max 1x per CPU; max 2x for System

DDR5 DIMM only configuration section

Min 1x DIMM per CPU is required. Any Mix of RDIMMx8, RDIMMx4, RDIMM 3DS is not allowed.

DDR5 Registered DIMM 4800MHz 1R/2R x8

16GB (1x16GB) 1Rx8 DDR5-4800 R ECC

max 8x per CPUPYBME16SLPY-ME16SL

32GB (1x32GB) 2Rx8 DDR5-4800 R ECC

max 8x per CPUPYBME32SLPY-ME32SL

max 8x per CPU; max 16x for System

DDR5 Registered DIMM 4800MHz 1R/2R x4

32GB (1x32GB) 1Rx4 DDR5-4800 R ECC

max 8x per CPUPYBME32SL2PY-ME32SL2

64GB (1x64GB) 2Rx4 DDR5-4800 R ECC

max 8x per CPUPYBME64SLPY-ME64SL

max 8x per CPU; max 16x for System

DDR5 Registered DIMM 4800MHz 3DS 4R/8R x4

128GB (1x128GB) 4Rx4 DDR5-4800 R 3DS ECC

max 8x per CPUPYBME12SLPY-ME12SL

256GB (1x256GB) 8Rx4 DDR5-4800 R 3DS ECC

max 8x per CPUPYBME25SLPY-ME25SL

max 8x per CPU; max 16x for System

D

cnfgTX2550M7-20231117_MPage 9 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

Detailed information

RAS feature

ECC

SDDC

ADDDC Sparing

Mirroring channel

Memory Mode

Normal Mode/Mirroring Mode

Normal Mode/Mirroring Mode

Normal Mode

Mirroring Mode

RDIMM

x8

yes

no

no

yes

RDIMM

LRDIMM

x4

yes

yes

yes

yes

BIOS setting

always enabled.

always enabled in case x4 DIMM conifugred.

disabled as default.

enabled in case Mirroring Mode ordered.

Configuration

Min. Memory

Max. Memory per CPU

Max. Memory per System

DIMM

1 Module / CPU

8 Module / CPU

16 Modules / CPU

32 Modules / System

CPU

with one CPU

with one CPU

with two CPU

with two CPU

Normal Mode

16GB: 16GB x1

-

2TB: 256GB x8

4TB: 256GB x16

Available Capacity

Mirroring Mode

-

64GB: 16GBx8x50%

1TB: 256GBx8x50%

2TB: 256GBx16x50%

The memory sockets on the Systemboards are color coded

C

h

a

n

n

e

l

G

C

h

a

n

n

e

l

A

C

h

a

n

n

e

l

B

C

h

a

n

n

e

l

C

C

h

a

n

n

e

l

D

Bank Iblack sockets

iMC0iMC1

CPU

iMC2iMC3

Normal Mode population DDR5 DIMM only

Normal Mode requires 1x, 2x, 4x, 6x or 8x DIMM configuration per CPU.

for 2x or more than 2x DIMM configuration,

Between Chanel A-E/C-G/B-F/D-H, balanced configuration is required. same bank of each chanel need to be populatd.

Between Chanel A-C-E-G/B-D-F-H, each chanel capacity need to be same if DIMM poputated in each Chanel.

1 DIMMs for 1CPU1 DIMMs for 1CPU

C

h

a

n

n

e

l

G

C

h

a

n

n

e

l

H

C

h

a

n

n

e

l

E

C

h

a

n

n

e

l

F

C

h

a

n

n

e

l

G

C

h

a

n

n

e

l

A

C

h

a

n

n

e

l

B

C

h

a

n

n

e

l

C

C

h

a

n

n

e

l

D

C

h

a

n

n

e

l

H

C

h

a

n

n

e

l

A

C

h

a

n

n

e

l

B

C

h

a

n

n

e

l

C

C

h

a

n

n

e

l

D

Data

iMC0iMC1

CPU

1 DIMMs for 1CPU1 DIMMs for 1CPU

iMC2iMC3iMC0iMC1

CPU

Data

iMC2iMC3

C

h

a

n

n

e

l

G

C

h

a

n

n

e

l

G

C

h

a

n

n

e

l

A

C

h

a

n

n

e

l

B

C

h

a

n

n

e

l

C

C

h

a

n

n

e

l

D

C

h

a

n

n

e

l

H

C

h

a

n

n

e

l

A

C

h

a

n

n

e

l

B

C

h

a

n

n

e

l

C

C

h

a

n

n

e

l

D

Data

iMC0iMC1

CPU

iMC2iMC3iMC0iMC1

CPU

iMC2

Data

iMC3

cnfgTX2550M7-20231117_M

C

h

a

n

n

e

l

H

C

h

a

n

n

e

l

E

C

h

a

n

n

e

l

E

C

h

a

n

n

e

l

F

C

h

a

n

n

e

l

F

C

h

a

n

n

e

l

H

C

h

a

n

n

e

l

E

C

h

a

n

n

e

l

E

C

h

a

n

n

e

l

F

C

h

a

n

n

e

l

F

Page 10 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

2 DIMMs for 1CPU

2x identical memory modules need to be populated.

2 DIMMs for 1CPU

2x identical memory modules need to be populated.

C

h

a

n

n

e

l

G

C

h

a

n

n

e

l

G

C

h

a

n

n

e

l

A

C

h

a

n

n

e

l

B

C

h

a

n

n

e

l

C

C

h

a

n

n

e

l

D

C

h

a

n

n

e

l

H

C

h

a

n

n

e

l

A

C

h

a

n

n

e

l

B

C

h

a

n

n

e

l

C

C

h

a

n

n

e

l

D

Data

iMC0iMC1

CPU

4 DIMMs for 1CPU

4x identical memory modules need to be populated.

iMC2

Data

iMC3iMC0

Data

iMC1

CPU

Data

iMC2iMC3

6 DIMMs for 1CPU

6x identical memory modules need to be populated.

C

h

a

n

n

e

l

G

C

h

a

n

n

e

l

G

C

h

a

n

n

e

l

A

C

h

a

n

n

e

l

B

C

h

a

n

n

e

l

C

C

h

a

n

n

e

l

D

C

h

a

n

n

e

l

H

C

h

a

n

n

e

l

A

C

h

a

n

n

e

l

B

C

h

a

n

n

e

l

C

C

h

a

n

n

e

l

D

Data

iMC0

Data

iMC1

CPU

Data

iMC2

Data

iMC3

Data

iMC0

Data

iMC1

DataData

iMC2

CPU

DataData

iMC3

6 DIMMs for 1CPU

6x identical memory modules need to be populated.

6 DIMMs for 1CPU

6x identical memory modules need to be populated.

C

h

a

n

n

e

l

G

C

h

a

n

n

e

l

G

C

h

a

n

n

e

l

A

C

h

a

n

n

e

l

B

C

h

a

n

n

e

l

C

C

h

a

n

n

e

l

D

C

h

a

n

n

e

l

H

C

h

a

n

n

e

l

A

C

h

a

n

n

e

l

B

C

h

a

n

n

e

l

C

C

h

a

n

n

e

l

D

Data

iMC0

DataData

iMC1

CPU

Data

iMC2

Data

iMC3

Data

iMC0

DataData

iMC1

DataData

iMC2

CPU

Data

iMC3

Data

6 DIMMs for 1CPU

6x identical memory modules need to be populated.

8 DIMMs for 1CPU

8x identical memory modules need to be populated.

C

h

a

n

n

e

l

G

C

h

a

n

n

e

l

G

C

h

a

n

n

e

l

A

C

h

a

n

n

e

l

B

C

h

a

n

n

e

l

C

C

h

a

n

n

e

l

D

C

h

a

n

n

e

l

H

C

h

a

n

n

e

l

A

C

h

a

n

n

e

l

B

C

h

a

n

n

e

l

C

C

h

a

n

n

e

l

D

Data

iMC0

Data

iMC1

Data

iMC2

CPU

DataData

iMC3

DataData

iMC0

DataData

iMC1

DataData

iMC2

CPU

DataData

iMC3

Data

Mirroring Mode population DDR5 DIMM only

Mirroring Mode requires 8x or 16x DIMM configuration per CPU.

in addition to Normal Mode Memory population rules,

Between Chanel A-B/C-D/E-F/G-H, identical DIMM need to be populated in same bank.

8 DIMMs for 1CPU

C

h

a

n

n

e

l

G

C

h

a

n

n

e

l

A

C

h

a

n

n

e

l

B

C

h

a

n

n

e

l

C

C

h

a

n

n

e

l

D

DataMirror

iMC0

DataMirror

iMC1

CPU

DataMirror

iMC2

DataMirror

iMC3

cnfgTX2550M7-20231117_

C

h

a

n

n

e

l

H

C

h

a

n

n

e

l

E

C

h

a

n

n

e

l

F

RAM

C

h

a

n

n

e

l

H

C

h

a

n

n

e

l

E

C

h

a

n

n

e

l

E

C

h

a

n

n

e

l

F

C

h

a

n

n

e

l

F

C

h

a

n

n

e

l

H

C

h

a

n

n

e

l

E

C

h

a

n

n

e

l

E

C

h

a

n

n

e

l

F

C

h

a

n

n

e

l

F

C

h

a

n

n

e

l

H

C

h

a

n

n

e

l

E

C

h

a

n

n

e

l

E

C

h

a

n

n

e

l

F

C

h

a

n

n

e

l

F

C

h

a

n

n

e

l

H

C

h

a

n

n

e

l

E

C

h

a

n

n

e

l

E

C

h

a

n

n

e

l

F

C

h

a

n

n

e

l

F

Page 11 of 43

The different GPU mixed configuration

does NOT support.

The different GPU mixed configuration

does NOT support.

These combination between RTX series and these Adapters(S26361-F4066-E12/L12,

S26361-F4066-E13/L13) are ristriction. It will be avaiable in 09.2023

FPGA Card T.B.D. to be available from GA

PRIMERGY TX2550 M7

System configurator and

order information guide

Chapter 6 - HD drive cage

F

HD drive cage is a metal box providing bays for 3.5" HDDs or 2.5" HDDs/SSDs/PCIe-SSDs. Choose out of the

following HD cage upgrade kits, depending on pre-selected TX2550 M7 base unit and the targeted configuration. Each upgrade kit contains all relevant

parts such as metal cage, backplane, cables and mounting material.

Upgrade kits for the upper drive area require the completion of the mid drive area.

Up to 3x 1.6x5.25" bays are available in the upper drive area for an ODD and/or backup drive configurations; in the 12x3.5" configuration, a 9.5mm bay is

available for a slim ODD. Refer to sections "ODD" and "backup" for details.

Upgrade kits are available either ex-factory (E-codes) or as loose delivery party (L-codes).

RAID configurations are recommendations; refer to section "RAID" for available options.

Preferred slots for controller assignementGeneral drive numbering scheme

Rear side view (incl. riser card option; refer to sheet "Description" for details)

TX2550 M7 front views of expandable base units and corresponding HD drive cage options:

If you change channel for HBA- or RAID-Controller as loose delivery, SAS cable need to be changed.

Option BPY-CBS085SAS cable for CP2100-8i

Option CPY-CBS086SAS cable for CP6xx/EP6xx/EP32xx

Base Unit

PY TX2550 M7 Tower, 4x3.5" basic

PYT2557T3N

RAID configuration1x HBA- or RAID-Controller. Refer to section "RAID" for options. Onboard SATA (max. 8x disks)

ODD / Backup3x 1.6x5.25" bays are available for an optical and/or backup drives in the upper drive area.

Upgrade kit for 4x3.5" HDD

PYBBA34SAPY-BA34SA

Upgrade kit for 4x3.5" HDD, mounted in the mid

drive area

Base Unit

PY TX2550 M7 Tower, 8x3.5"PY TX2550 M7 Rack, 8x3.5"

PYT2557TANPYT2557R3N

RAID configuration1x HBA- or RAID-Controller. Refer to section "RAID" for options. onboard SATA(Max. qty. for Disk is eight.)

if no upper drive area is installed, the below can be selected.

ODD / Backup3x 1.6x5.25" bays are available for an optical and/or backup drives in the upper drive area.

HD cage upgrades for upper drive area

Upgrade kit for 4x3.5" HDD

PYBBA34SBPY-BA34SB

Upgrade kit for 4x3.5" HDD, mounted in the

upper drive area,

incl. 40x SAS Expander

1x 9.5mm bay is available for a slim optical drive

in the upper drive area.

Note! This option requires 1x PRAID/HBA per

Base unit

RAID configuration1x HBA- or RAID-Controller. Refer to section "RAID" for options.

ODD / Backup1x 9.5mm bay is available for a slim optical drive in the upper drive area.

Base Unit

PY TX2550 M7 Tower, 8x2.5" basic

PYT2557T2N

RAID configuration1x HBA- or RAID-Controller. Refer to section "RAID" for options. onboard SATA(Max. qty. for Disk is eight.)

ODD / Backup3x 1.6x5.25" bays are available for an optical and/or backup drives in the upper drive area.

cnfgTX2550M7-20231117__cagePage 14 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

Base unit

PY TX2550 M7 Tower, 8x2.5"PY TX2550 M7 Rack, 8x2.5"

PYT2557TBNPYT2557R2N

RAID configuration1x HBA- or RAID-Controller. Refer to section "RAID" for options. onboard SATA(Max. qty. for Disk is eight.)

if no upper drive area is installed, the below can be selected.

ODD / Backup3x 1.6x5.25" bays are available for an optical and/or backup drives in the upper drive area.

HD cage upgrades

Upgrade kit for 8x2.5" HDDUpgrade kit for 8x2.5" HDD

PYBBA28SQPY-BA28SQPYBBA28SRPY-BA28SR

Upgrade kit for 8x2.5" HDD, mounted in the mid Upgrade kit for 8x2.5" HDD, mounted in the mid

drive area,drive area,

for connect 16port RAID option

incl. 40x SAS Expander

Note! This option requires 1x 16-channel

PRAID/HBA

Note! This option requires 1x PRAID/HBA

Upgrade kit for the upper drive area

Please refer to “Upgrade kit for the upper drive area with PYT2557TBN/ PYT2557R2N/ PYT2557TCN/ PYT2557RAN

Base unit

PY TX2550 M7 Tower, 24x2.5"PY TX2550 M7 Rack, 24x2.5"

PYT2557TCNPYT2557RAN

Including 40x SAS Expander!

RAID configuration1x HBA- or RAID-Controllers. Refer to section "RAID" for options.

ODD / Backup3x 1.6x5.25" bays are available for an optical and/or backup drives in the upper drive area.

HD cage upgrades

Upgrade kit for the upper drive area

Please refer to “Upgrade kit for the upper drive area with PYT2557TBN/ PYT2557R2N/ PYT2557TCN/ PYT2557RAN

cnfgTX2550M7-20231117__cagePage 15 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

The mix configuration information

Upgrade kit for the upper drive area with PYT2557TBN/ PYT2557R2N/ PYT2557TCN/ PYT2557RAN

Only one of them can be selected.

Upgrade kit for 8x2.5" HDD

PYBBA28SS

8x2.5"

PY-BA28SS

Upgrade kit for 8x2.5" HDD(SAS4)8x2.5" combo HDD

Note!

This option requires 2x CPUs.

This option requires min. 1x 24Gb/s PRAID/HBA

In total, 2x PRAID/ HBA are allowed (1x for bottom / mid area,

1x for upper area). Choose from the options below:

PYBBA28ST

[Option 1] – Choose two of the following:

- 1x for bottom / mid area :

PRAID EP 325x-xi [PYBSR4MA1L/PY-

SR4MA1/PYBSR4MA2L/PY-SR4MA2/PYBSR4MA3L/PY-

SR4MA3],

or PSAS CP 2200-16i [PYBSC4MA1L/PY-SC4MA1]

or PSAS CP 2100-8i [PYBSC3MA2L/PY-SC3MA2].

- 1x for upper area :

PRAID EP 325x-xi [PYBSR4MA1L/PY-

SR4MA1/PYBSR4MA2L/PY-SR4MA2/PYBSR4MA3L/PY-

SR4MA3],

or PSAS CP 2200-16i [PYBSC4MA1L/PY-SC4MA1]

PY-BA28ST

[Option 2] – Choose two of the following:

- 1x for bottom / mid area :

PSAS CP600i[PYBSC4FAL/PY-SC4FA],

or PRAID CP600i[PYBSR4FAL/PY-SR4FA],

or PRAID EP740i[PYBSR4C71L/PY-SR4C71],

or PRAID EP6x0i[PYBSR4C63L/PY-SR4C63/PYBSR4C6L/PY-

SR4C6]

- 1x for upper area :

Upgrade kit for 1-4 x2.5" PCIe SSD SFF w/

PYBBA24PJ

8x2.5" combo HDD

onBoard

PY-BA24PJ

Upgrade kit for 1-4 x2.5" PCIe SSD SFF w/

PYBBA24PK

8x2.5" combo HDD

PRAID

Note!

PY-BA24PK

This option requires 1x PRAID for NVMe.

upgrade kit for 5-8 x2.5" PCIe SSD SFF w/

PYBCBE024

Note!

onBoardThis option requires 2x CPUs.

PY-CBE024

This option requires PYBBA24PJ.

Upgrade kit for 5-8 x2.5" PCIe SSD SFF w/ Note!

PRAID

PYBCBE025

This option requires 2x CPUs.

PY-CBE025

This option requires another PRAID for NVMe.

This option requires PYBBA24PK.

RAID configurationHBA- or RAID- or Retimer-Controllers. Refer to section "RAID" for options.

ODD / Backup

1x 1.6x5.25" bay is available for an optical or backup drive in the upper drive area.

Note! One of LTO and ODD can be selected.

G

cnfgTX2550M7-20231117__cagePage 16 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

Chapter 7 - SAS / RAID Controller

G

FH PCIe card requires FH PCIe riser card. Please refer to ''Chapter 14 - PCI riser card'.

onboard SATA controller with SW-RAID

onboard controller for SATA HDD or SSD drives

6Gb/s SATAIntel VROC (SATA RAID) based on chipset

BIOS version R1.6.0 or later is required to use Intel VROC (SATA RAID)

No CacheSW-RAID 0, 1, 102xonboard, included

intenal HBA and RAID controller, no 2nd Level cache

internal RAID / HBA controllers for SAS, SATA HDD or SSD drives

RAID 0, 1, 10

PRAID CP600i LPNo Cache

8 ports 3, 6 & 12Gb/s SAS/SATA HDD/SSD, supports up to 8 drives without expander

supports SED (Self Encrypting Drives)

requires 1x LP PCIe 4.0 x8 (int.) slot, based on LSI SAS3808

HBA, no RAID

PSAS CP600i LPNo Cache

16 ports 3, 6 & 12Gb/s SAS/SATA HDD/SSD, supports up to 16 drives without expander

limitation: supports up to 30 drives only with expander

requires 1x LP PCIe 4.0 x8 (int.) slot, based on LSI SAS3816; IT FW stack without RAID functionality

PYBSR4FAL

PY-SR4FA

PYBSC4FALPY-SC4FA

internal RAID / HBA controllers for SAS, SATA HDD or SSD drives

HBA + RAID 0, 1, 10, 5PYBSC4MA1LPY-SC4MA1

No Cache

PSAS CP 2200-16i LP available from 2024/03

16 ports 6, 12 & 24Gb/s SAS/SATA HDD/SSD, supports up to 16 SAS/SATA drives without expander

(the configuration for up to 4 x4 NVMe drives requires a different order number, please see below)

supports SED (Self Encrypting Drives)

requires 1x LP PCIe 4.0 x8 (int.) slot

* max. 2x, when Upgrade kit for 8x2.5" HDD(SAS4): PYBBA28ST is ordered

(FYI: PYBSC4MA1L and PYBSC4MA2(L) are identical products. The 2nd Order number was only introduced for explicite ordering and cabling)

HBA + RAID 0, 1, 10, 5

PSAS CP 2100-8i LPNo Cache

8 ports 3, 6 & 12Gb/s SAS/SATA HDD/SSD, supports up to 8 devices without expander

requires 1x LP PCIe 3.0 x8 (int.) slot

PYBSC3MA2LPY-SC3MA2

internal RAID / HBA controllers for PCIe SSD drives

HBA + RAID 0, 1, 10, 5PYBSC4MA2

No Cache

PSAS CP 2200-16i NVMe FH

available from 2024/03

PY-SC4MA1

HBA + RAID 0, 1, 10, 5PYBSC4MA2L

No Cache

PSAS CP 2200-16i NVMe LP

available from 2024/03

up to 4 x4 NVMe drives are supported. (the configuration for SAS/SATA only requires a different order number, please see above)

requires 1x FH or LP PCIe 4.0 x8 (int.) slot

(FYI: PYBSC4MA1L and PYBSC4MA2(L) are identical products. The 2nd Order number was only introduced for explicite ordering and cabling)

internal RAID controller with 2nd Level cache

internal RAID controllers for SAS, SATA HDD or SSD drives

PYBSR4C71LPY-SR4C71

PRAID EP740i LP available from 2024/07

4GB Cache

RAID 0, 1, 10, 5, 50, 6, 60

16 ports 6, 12 & 24Gb/s SAS/SATA HDD/SSD, supports up to 16 SAS/SATA drives without expander

(the configuration for up to 4 x4 NVMe drives requires a different order number, please see below)

supports SED (Self Encrypting Drives)

requires 1x LP PCIe 4.0 x8 (int.) slot, based on LSI SAS4116

* max. 2x, when Upgrade kit for 8x2.5" HDD(SAS4): PYBBA28ST is ordered

(FYI: PYBSR4C71L and PYBSR4C72(L) are identical products. The 2nd Order number was only introduced for explicite ordering and cabling)

internal RAID controllers for SAS, SATA HDD or SSD drives

PRAID EP640i LP4GB Cache

RAID 0, 1, 10, 5, 50, 6, 60

8 ports 3, 6 & 12Gb/s SAS/SATA HDD/SSD, supports up to 8 drives without expander

supports SED (Self Encrypting Drives)

requires 1x LP PCIe 4.0 x8 (int.) slot, based on LSI SAS3908

PYBSR4C63LPY-SR4C63

PRAID EP680i LP8GB CachePYBSR4C6LPY-SR4C6

RAID 0, 1, 10, 5, 50, 6, 60

16 ports 3, 6 & 12Gb/s SAS/SATA HDD/SSD, supports up to 16 SAS/SATA drives without expander

(the configuration for up to 4 x4 NVMe drives requires a different order number, please see below)

supports SED (Self Encrypting Drives)

requires 1x LP PCIe 4.0 x8 (int.) slot, based on LSI SAS3916

(FYI: PYBSR4C6L and PYBSR4C62(L) are identical products. The 2nd Order number was only introduced for explicite ordering and cabling)

optional Flash Backup Unit (FBU)

FBU option for PRAID EP6xx / EP7xx: Supercap securing the power supply of the RAID controller in case of

S26361-F4042-E155

power failure including cable with 55cm length

S26361-F4042-L110

cnfgTX2550M7-20231117_IDPage 17 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

internal RAID controllers for PCIe SSD drives

4GB CachePYBSR4C72

PRAID EP740i NVMe FH

available from 2024/07

RAID 0, 1, 10, 5, 50, 6, 60

PY-SR4C71

4GB CachePYBSR4C72L

PRAID EP740i NVMe LP

available from 2024/07

RAID 0, 1, 10, 5, 50, 6, 60

up to 4 x4 NVMe drives are supported. (the configuration for SAS/SATA only requires a different order number, please see above)

requires 1x FH or LP PCIe 4.0 x8 (int.) slot, based on LSI SAS4116

(FYI: PYBSR4C71L and PYBSR4C72(L) are identical products. The 2nd Order number was only introduced for explicite ordering and cabling)

optional Flash Backup Unit (FBU)

S26361-F4042-L110

FBU option for PRAID EP7xx: Supercap securing the power supply of the RAID controller in case of power

S26361-F4042-E155

failure including cable with 55cm length

internal RAID controllers for PCIe SSD drives

PRAID EP680i NVMe FH8GB CachePYBSR4C62

RAID 0, 1, 10, 5, 50, 6, 60

PY-SR4C6

PRAID EP680i NVMe LP8GB CachePYBSR4C62L

RAID 0, 1, 10, 5, 50, 6, 60

up to 4 x4 NVMe drives are supported. (the configuration for SAS/SATA only requires a different order number, please see above)

no FBU is allowed for this controller

requires 1x FH or LP PCIe 4.0 x8 (int.) slot, based on LSI SAS3916

(FYI: PYBSR4C6L and PYBSR4C62(L) are identical products. The 2nd Order number was only introduced for explicite ordering and cabling)

internal RAID controllers for SAS, SATA HDD or SSD drives

PRAID EP 3252-8i LP2GB Cache

RAID 0, 1, 10, 5, 50, 6, 60

PRAID EP 3254-8i LP4GB Cache

RAID 0, 1, 10, 5, 50, 6, 60

8 ports 6, 12 & 24Gb/s SAS/SATA HDD/SSD, supports up to 8 drives without expander

supports SED (Self Encrypting Drives)

requires 1x LP PCIe 4.0 x8 (int.) slot

* max. 2x, when Upgrade kit for 8x2.5" HDD(SAS4): PYBBA28ST is ordered

PYBSR4MA1L

PYBSR4MA2L

PY-SR4MA1

PY-SR4MA2

PRAID EP 3258-16i LP8GB CachePYBSR4MA3LPY-SR4MA3

RAID 0, 1, 10, 5, 50, 6, 60

16 ports 6, 12 & 24Gb/s SAS/SATA HDD/SSD, supports up to 16 SAS/SATA drives without expander

(the configuration for up to 4 x4 NVMe drives requires a different order number, please see below)

supports SED (Self Encrypting Drives)

requires 1x LP PCIe 4.0 x8 (int.) slot

* max. 2x, when Upgrade kit for 8x2.5" HDD(SAS4): PYBBA28ST is ordered

(FYI: PYBSR4MA3L and PYBSR4MA4(L) are identical products. The 2nd Order number was only introduced for explicite ordering and cabling)

optional Flash Backup Unit (FBU)

FBU option for PRAID EP 325x in rear PCIe Slot#1: Supercap securing the power supply of the RAID

controller in case of power failure without extension cable

FBU option for PRAID EP 325x in rear PCIe Slot#8: Supercap securing the power supply of the RAID

controller in case of power failure including cable with 46cm length

PYBFBM014

PYBFBM012

PY-FBM01

PY-FBM01

internal RAID controllers for PCIe SSD drives

PRAID EP 3258-16i NVMe FH8GB CachePYBSR4MA4

RAID 0, 1, 10, 5, 50, 6, 60

PY-SR4MA3

PRAID EP 3258-16i NVMe LP8GB CachePYBSR4MA4L

RAID 0, 1, 10, 5, 50, 6, 60

available from 2024/03

up to 4 x4 NVMe drives are supported. (the configuration for SAS/SATA only requires a different order number, please see above)

requires 1x FH or LP PCIe 4.0 x8 (int.) slot

(FYI: PYBSR4MA3L and PYBSR4MA4(L) are identical products. The 2nd Order number was only introduced for explicite ordering and cabling)

optional Flash Backup Unit (FBU) available from 2024/03

FBU option for PRAID EP 325x in rear PCIe Slot#3/#4/#8: Supercap securing the power supply of the RAID

PYBFBM012

controller in case of power failure including cable with 46cm length

PY-FBM01

FBU cannot be combined with Advanced Thermal design.

up to 3x FBU can be integrated per System

Group A and Group B cannot be mixed

Group A and Group C can be mixed

Group B and Group C can be mixed

Group AGroup B

PSAS CP600iPSAS CP 2100-8i

PSAS CP600i for LTOPSAS CP 2200-16i

PRAID CP600iPSAS CP 2200-16i NVMe

PRAID EP740iPSAS CP 2200-16i for LTO

PRAID EP740i NVMePRAID EP 3252-8i

PRAID EP640iPRAID EP 3254-8i

PRAID EP680iPRAID EP 3258-16i

PRAID EP680i NVMePRAID EP 3258-16i NVMe

Group C

PSAS CP600e

PRAID EP680e

cnfgTX2550M7-20231117_IDPage 18 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

H

external HBA controller, no 2nd Level cache

external HBA controllers for SAS HDD or SSD drives

HBA, no RAID

PSAS CP600e FHNo Cache

HBA, no RAID

PSAS CP600e LPNo Cache

16 ports 3, 6 & 12Gb/s SAS/SATA HDD/SSD, 4x SFF8644 (external Mini-SAS HD)

requires 1x FH or LP PCIe 4.0 x8 (int.) slot, based on LSI SAS3816

PYBSC4FAE

PYBSC4FAEL

PY-SC4FAE

external RAID controller with 2nd Level cache

external RAID controllers for SAS HDD or SSD drives

PRAID EP680e FH8GB CacheRAID 0, 1, 10, 5, 50, 6, 60

PRAID EP680e LP8GB CacheRAID 0, 1, 10, 5, 50, 6, 60

8 ports 3, 6 & 12Gb/s SAS/SATA HDD/SSD, 2x SFF8644 (external Mini-SAS HD)

supports SED (Self Encrypting Drives)

requires 1x FH or LP PCIe 4.0 x8 (int.) slot, based on LSI SAS3916

optional Flash Backup Unit (FBU)

FBU option for PRAID EP6xx: Supercap securing the power supply of the RAID controller in case of power

failure including cable with 55cm length

PYBSR4C6E

PYBSR4C6EL

PY-SR4C6E

S26361-F4042-E155S26361-F4042-L110

internal controller for PCIe SSD (NVMe SSD), no HW-RAID

internal controller for PCIe SSD (NVMe SSD)

PCIeIntel CPUNo Cache

optional Licence Activation Key for Intel VROC (VMD NVMe RAID)

No Cache

Intel VROC Upgrade Key Premium

Intel CPU

BIOS version R1.6.0 or later is required to use Intel VROC (VMD NVMe RAID)

* RAID 1 is only supported In VMware ESXi.

I

No HW-RAID

SW-RAID 0, 1, 10, 5 *

-

1x

onboard, included

PYBRLVR02PY-RLVR02

cnfgTX2550M7-20231117_IDPage 19 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

Chapter 8 - ODD optical disk drives

PRIMERGY TX2550 M7offers up to 3x 1.6” bays (located in the upper side of Tower-/ right side of Rack-server) for various ODD's and/or backup drives.

Depending on the HDD drive cage configuration there may be some or all of 1.6” bays already occupied;please find the number of availablebays in the chapter 6, "HD-cage", incl. further configuration details.

I1

12x 3.5" configuration

with 1x 9.5mm bay

I2

Configurations

with min. 1x free 1.6" bay

S26361-F3778-E1

S26361-F3778-L1

DVD-RW supermulti ultra slim

all formats, DUAL/DL, DVD-

RAM only W2K, W3K and

Linux

S26361-F3641-E6

S26361-F3641-L6

Blu-ray Triple Writer ultra slim

6x BD-RW, 8x DVD, 24x CD,

BD DL and all CD/DVD

formats

will be EOL in CQ2'24

S26361-F3266-E2

S26361-F3266-L2

DVD-ROM

DVD-ROM or CD-ROM

will be EOL in CQ2'24

S26361-F3267-E2

S26361-F3267-L2

DVD-RW supermulti SATA

all formats, DUAL/DL, DVD-

RAM only W2K, W3K and Linux

S26361-F3641-E8

S26361-F3641-L8

Blu-ray Triple Writer SATA

6x BD-RW, 8x DVD, 24x CD, BD

DL and all CD/DVD formats.

9.5mm ultra slim drive integrated

into a 5.25" bay.

9.5mm, black bezel

max. 1x per system

9.5mm, black bezel

max. 1x per system

1.6" * 5.25" black bezel

max. 1x per system

1.6" * 5.25" black bezel

max. 1x per system

9.5mm at 1.6" *5.25" black bezel

max. 1x per system

will be available in CQ2'24will be available in CQ2'24

PYBDV122PYBDR122

PY-DV122PY-DR122

DVD-ROMDVD-RW supermulti SATA

DVD-ROM or CD-ROMall formats, DUAL/DL, DVD-

RAM only W2K, W3K and Linux

9.5mm at 1.6" *5.25" black bezel

max. 1x per system

9.5mm at 1.6" *5.25" black bezel

max. 1x per system

J

cnfgTX2550M7-20231117_DPage 20 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

Chapter 9 - backup drives

With mostconfigurations the TX2550 M7 offers 3 x 1.6” bay in the accessible drives area located at the top of the Tower Server (or at the right side of the Rack) for various ODD and or backup drives.

Depending on the HDD drive configuration there may be some or all of these 1.6” bays already occupied-please find the number of availablebays and the size listed as point 3)at each of the drive

bundles. All bundles with limitations are highlighted with 2 exclamation marks in the front (e.g. "!! 1x 9.5mm ...")

J

Config. with min. 1x free 1.6" bay

SAS HBA card for Internal LTO drives

Note: In case SATA/SAS/NVMe with Raid card and PCI Riser rights(PYBPRE638/PY-PRE638/PYBPRE641/PY-PRE641/PYBPRE848/PY-PRE848/PYBPRE643/PY-

PRE643/PYBPRE645/PY-PRE645/PYBPRE851/PY-PRE851) exists, this can't be used.

SAS HBA Controller

PYBSC4FA2LPY-SC4FA

PSAS CP600i LP for LTO

requires 1x LP PCIe 4.0 x8 / for LTO drives1x

PYBSC4MA3LPY-SC4MA1

PSAS CP 2200-16i LP for LTO

requires 1x LP PCIe 4.0 x8 / for LTO drives available from 2024/031x

LTO drives (Need to select one of LTO drives togheter with SAS HBA)

LTO drives are not including tape drives. Cleaning Cartridge and Cables are included

LTO 7 tape drive (w/o tape)

6.0TB, 300MB/s, SAS 2.0, 5.25 inch/HalfHeight

LTO 8 tape drive (w/o tape)

12.0TB, 300MB/s, SAS 2.0, 5.25 inch/HalfHeight

LTO 9 tape drive (w/o tape)

18.0TB, 300MB/s, SAS 3.0, 5.25 inch/HalfHeight

1x

1x

1x

S26361-F5606-E1

S26361-F5789-E1

PYBLT911

S26361-F5606-L1

S26361-F5789-L1

PY-LT911

RDX drives

RDX drive is not including Cartridge.

RDX Drive cage (w/o cartriges)

USB 3.0, 5.25 inch / Half Height

RDX

RDX Cartrridge

RDX Cartridge 500GB

RDX Cartridge 1TB

RDX Cartridge 2TB

RDX Cartridge 4TB

1x

S26361-F3750-E4S26361-F3750-L4

-

-

-

-

-

-

-

-

S26361-F3857-L500

S26361-F3857-L600

S26361-F3857-L700

S26361-F3857-L900

K

cnfgTX2550M7-20231117_ckupPage 21 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

Chapter 10 - storage drives

SAS drives and SATA drives can be mixed, but cannot be used in one logical RAID volume.

SATA drives can be connected to the onboard Controller (max. 8x),

SAS drives require a dedicated SAS / RAID Controller

PCIe-SSDs can be connected to the onboard Controller, or require a dedicated RAID Controller or PCIe retimer/switch card.

Hard Disk Sector Format Information:

512n HDD: 512 byte sectors on the drive media.

512e (e=emulation) HDD: 4K physical sectors on the drive media with 512 byte logical configuration.

512e HDD Disk Drives: VMware 6.0 or earlier is not supported.

When using SSDs with VMware ESXi, select the SSDs that meet the endurance requirement describedin

KB2145210 below.

/kb/2145210

DWPD: Drive Writes Per Day over 5 years.

SED/FIPS are Self Encrypting Drives, and they require either a RAID controller with ®SafeStore (SED) support or an HBA and

in addition a software instance, supporting SED Key Management.

It is strongly recommended to order SafeStore (SED) RAID controller with SEDHDD or SSD devices for SafeStore (SED) functionality.

Non-SED drives and SED/FIPS drives can be mixed, but cannot be used in one logical RAID volume.

HDD Classes:

Business-Critical (BC) -SATA=Nearline SATA Enterprise Drives / 7.2Krpm,SATA 6G.

Business-Critical (BC) -SAS=Nearline SAS Enterprise Drives / 7.2Krpm,SAS 12G.

Mission-Critical (MC)=SAS 10K and SAS 15K Enterprise Drives with max. performance and reliability.

Warranty:

SSD and SATA DOM have a built-in Wear-Out indicator. In this case the warranty for such a component, as an

exception to the system warranty, is restricted to the time period until the indicator reaches the exhaust level.

K

2.5" (SFF) SAS and SATA SSD

SSD SAS 2.5" Write Intensive

(SFF) Enterprise with hot plug/hot replace tray

based on Kioxia PM7 drives

CapacityFormfactor

InterfaceEnduranceDWPDorder code E-partorder code L-part

800GB2.5" (SFF)

SAS 24Gb/sWrite Intensive10

PYBSS80NGFPY-SS80NGF

1.6TB2.5" (SFF)

SAS 24Gb/sWrite Intensive10

PYBSS16NGFPY-SS16NGF

800GB2.5" (SFF)

SAS 24Gb/sWrite Intensive10

SED FIPS available in CY24Q1

PYBSS80NGGPY-SS80NGG

1.6TB2.5" (SFF)

SAS 24Gb/sWrite Intensive10

SED FIPS available in CY24Q1

PYBSS16NGGPY-SS16NGG

max. 8x, 16x, 24x or 32x - depending on base unit & configuration

SSD SAS 2.5" Write Intensive

(SFF) Enterprise with hot plug/hot replace tray

based on Seagate Nytro3732/3750 drives

CapacityFormfactor

InterfaceEnduranceDWPDorder code E-partorder code L-part

400GB 2.5" (SFF)

SAS 12Gb/sWrite Intensive10

PYBSS40NGAPY-SS40NGA

800GB2.5" (SFF)

SAS 12Gb/sWrite Intensive10

PYBSS80NGAPY-SS80NGA

1.6TB2.5" (SFF)

SAS 12Gb/sWrite Intensive10

PYBSS16NGAPY-SS16NGA

400GB 2.5" (SFF)

SAS 12Gb/sWrite Intensive10 SED

PYBSS40NGWPY-SS40NGW

800GB2.5" (SFF)

SAS 12Gb/sWrite Intensive10 SED

PYBSS80NGWPY-SS80NGW

1.6TB2.5" (SFF)

SAS 12Gb/sWrite Intensive10 SED

PYBSS16NGWPY-SS16NGW

max. 8x, 16x, 24x or 32x - depending on base unit & configuration

SSD SAS 2.5" Mixed Use

(SFF) Enterprise with hot plug/hot replace tray

based on Kioxia PM7 drives

CapacityFormfactor

InterfaceEnduranceDWPDorder code E-partorder code L-part

1.6TB2.5" (SFF)

SAS 24Gb/sMixed Use3

PYBSS16NPMPY-SS16NPM

3.2TB2.5" (SFF)

SAS 24Gb/sMixed Use3

PYBSS32NPMPY-SS32NPM

6.4TB2.5" (SFF)

SAS 24Gb/sMixed Use3

PYBSS64NPMPY-SS64NPM

max. 8x, 16x, 24x or 32x - depending on base unit & configuration

SSD SAS 2.5" Mixed Use

(SFF) Enterprise with hot plug/hot replace tray

based on Seagate Nytro3532/3550 drives

CapacityFormfactor

InterfaceEnduranceDWPDorder code E-partorder code L-part

800GB2.5" (SFF)

SAS 12Gb/sMixed Use3

PYBSS80NPFPY-SS80NPF

1.6TB2.5" (SFF)

SAS 12Gb/sMixed Use3

PYBSS16NPFPY-SS16NPF

3.2TB2.5" (SFF)

SAS 12Gb/sMixed Use3

PYBSS32NPFPY-SS32NPF

6.4TB2.5" (SFF)

SAS 12Gb/sMixed Use3

PYBSS64NPFPY-SS64NPF

max. 8x, 16x, 24x or 32x - depending on base unit & configuration

cnfgTX2550M7-20231117__SSDPage 22 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

SSD SAS 2.5" Read Intensive

(SFF) Enterprise with hot plug/hot replace tray

based on Kioxia PM7 drives

CapacityFormfactor

InterfaceEnduranceDWPDorder code E-partorder code L-part

1.92TB 2.5" (SFF)

SAS 24Gb/sRead Intensive1

PYBSS19NNMPY-SS19NNM

3.84TB 2.5" (SFF)

SAS 24Gb/sRead Intensive1

PYBSS38NNLPY-SS38NNL

7.68TB 2.5" (SFF)

SAS 24Gb/sRead Intensive1

PYBSS76NNMPY-SS76NNM

15.36TB 2.5" (SFF)

SAS 24Gb/sRead Intensive1

PYBSS15NNLPY-SS15NNL

7.68TB 2.5" (SFF)

SAS 24Gb/sRead Intensive1

SED FIPS available in CY24Q1

PYBSS76NNNPY-SS76NNN

15.36TB 2.5" (SFF)

SAS 24Gb/sRead Intensive1

SED FIPS available in CY24Q1

PYBSS15NNMPY-SS15NNM

max. 8x, 16x, 24x or 32x - depending on base unit & configuration

will be available in CQ4'23

SSD SAS 2.5" Read Intensive

(SFF) Enterprise with hot plug/hot replace tray

based on Samsung PM1653 drives

CapacityFormfactor

InterfaceEnduranceDWPDorder code E-partorder code L-part

960GB 2.5" (SFF)

SAS 24Gb/sRead Intensive1 SED

PYBSS96NNMPY-SS96NNM

1.92TB 2.5" (SFF)

SAS 24Gb/sRead Intensive1 SED

PYBSS19NNPPY-SS19NNP

3.84TB 2.5" (SFF)

SAS 24Gb/sRead Intensive1 SED

PYBSS38NNNPY-SS38NNN

7.68TB 2.5" (SFF)

SAS 24Gb/sRead Intensive1 SED

PYBSS76NNPPY-SS76NNP

15.36TB 2.5" (SFF)

SAS 24Gb/sRead Intensive1 SED

PYBSS15NNNPY-SS15NNN

This SSDs can be used as Non-SED drives, but it requires a RAID controller with SED support for using as SED drives.

max. 8x, 16x, 24x or 32x - depending on base unit & configuration

SSD SAS 2.5" Read Intensive

(SFF) Enterprise with hot plug/hot replace tray

based on Seagate Nytro3332/3350 drives

CapacityFormfactor

InterfaceEnduranceDWPDorder code E-partorder code L-part

960GB 2.5" (SFF)

SAS 12Gb/sRead Intensive1

PYBSS96NNJPY-SS96NNJ

1.92TB 2.5" (SFF)

SAS 12Gb/sRead Intensive1

PYBSS19NNHPY-SS19NNH

3.84TB 2.5" (SFF)

SAS 12Gb/sRead Intensive1

PYBSS38NNHPY-SS38NNH

7.68TB 2.5" (SFF)

SAS 12Gb/sRead Intensive1

PYBSS76NNHPY-SS76NNH

15.36TB 2.5" (SFF)

SAS 12Gb/sRead Intensive1

PYBSS15NNGPY-SS15NNG

max. 8x, 16x, 24x or 32x - depending on base unit & configuration

will be available in CQ1'24

SSD SATA 2.5" Mixed Use (SFF)

Enterprise with hot plug/hot replace tray

based on Samsung PM897a drives

CapacityFormfactor

InterfaceEnduranceDWPDorder code E-partorder code L-part

480GB2.5" (SFF)

SATA 6Gb/sMixed Use3 SED

PYBSS48NKSPY-SS48NKS

960GB2.5" (SFF)

SATA 6Gb/sMixed Use3 SED

PYBSS96NKSPY-SS96NKS

1.92TB2.5" (SFF)

SATA 6Gb/sMixed Use3 SED

PYBSS19NKSPY-SS19NKS

3.84TB2.5" (SFF)

SATA 6Gb/sMixed Use3 SED

PYBSS38NKSPY-SS38NKS

This SSDs can be used as Non-SED drives, but it requires a RAID controller with SED support for using as SED drives.

max. 8x, 16x, 24x or 32x - depending on base unit & configuration

SSD SATA 2.5" Mixed Use (SFF)

Enterprise with hot plug/hot replace tray

based on Samsung PM897 drives

CapacityFormfactor

InterfaceEnduranceDWPDorder code E-partorder code L-part

480GB2.5" (SFF)

SATA 6Gb/sMixed Use3

PYBSS48NKQPY-SS48NKQ

960GB2.5" (SFF)

SATA 6Gb/sMixed Use3

PYBSS96NKQPY-SS96NKQ

1.92TB2.5" (SFF)

SATA 6Gb/sMixed Use3

PYBSS19NKQPY-SS19NKQ

3.84TB2.5" (SFF)

SATA 6Gb/sMixed Use3

PYBSS38NKQPY-SS38NKQ

max. 8x, 16x, 24x or 32x - depending on base unit & configuration

SSD SATA 2.5" Mixed Use (SFF)

Enterprise with hot plug/hot replace tray

based on Micron 5300/5400 MAX drives

CapacityFormfactor

InterfaceEnduranceDWPDorder code E-partorder code L-part

480GB2.5" (SFF)

SATA 6Gb/sMixed Use5,0

S26361-F5776-E480S26361-F5776-L480

960GB2.5" (SFF)

SATA 6Gb/sMixed Use5,0

S26361-F5776-E960S26361-F5776-L960

1.92TB2.5" (SFF)

SATA 6Gb/sMixed Use5,0

S26361-F5776-E192S26361-F5776-L192

3.84TB2.5" (SFF)

SATA 6Gb/sMixed Use3,5

S26361-F5776-E384S26361-F5776-L384

max. 8x, 16x, 24x or 32x - depending on base unit & configuration

will be available in CQ1'24

cnfgTX2550M7-20231117__SSDPage 23 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

SSD SATA 2.5" Read Intensive (SFF)

Enterprise with hot plug/hot replace tray

based on Samsung PM893a drives

CapacityFormfactor

InterfaceEnduranceDWPDorder code E-partorder code L-part

480GB2.5" (SFF)

SATA 6Gb/sRead Intensive1,0 SED

PYBSS48NMEPY-SS48NME

960GB2.5" (SFF)

SATA 6Gb/sRead Intensive1,0 SED

PYBSS96NMEPY-SS96NME

1.92TB2.5" (SFF)

SATA 6Gb/sRead Intensive1,0 SED

PYBSS19NMEPY-SS19NME

3.84TB2.5" (SFF)

SATA 6Gb/sRead Intensive1,0 SED

PYBSS38NMEPY-SS38NME

7.68TB2.5" (SFF)

SATA 6Gb/sRead Intensive1,0 SED

PYBSS76NMEPY-SS76NME

This SSDs can be used as Non-SED drives, but it requires a RAID controller with SED support for using as SED drives.

max. 8x, 16x, 24x or 32x - depending on base unit & configuration

SSD SATA 2.5" Read Intensive (SFF)

Enterprise with hot plug/hot replace tray

based on Samsung PM893 drives

CapacityFormfactor

InterfaceEnduranceDWPDorder code E-partorder code L-part

240GB2.5" (SFF)

SATA 6Gb/sRead Intensive1,0

PYBSS24NMDPY-SS24NMD

480GB2.5" (SFF)

SATA 6Gb/sRead Intensive1,0

PYBSS48NMDPY-SS48NMD

960GB2.5" (SFF)

SATA 6Gb/sRead Intensive1,0

PYBSS96NMDPY-SS96NMD

1.92TB2.5" (SFF)

SATA 6Gb/sRead Intensive1,0

PYBSS19NMDPY-SS19NMD

3.84TB2.5" (SFF)

SATA 6Gb/sRead Intensive1,0

PYBSS38NMDPY-SS38NMD

7.68TB2.5" (SFF)

SATA 6Gb/sRead Intensive1,0

PYBSS76NMDPY-SS76NMD

max. 8x, 16x, 24x or 32x - depending on base unit & configuration

SSD SATA 2.5" Read Intensive (SFF)

Enterprise with hot plug/hot replace tray

based on Micron 5300/5400PRO drives

CapacityFormfactor

InterfaceEnduranceDWPDorder code E-partorder code L-part

240GB2.5" (SFF)

SATA 6Gb/sRead Intensive1,5

S26361-F5783-E240S26361-F5783-L240

480GB2.5" (SFF)

SATA 6Gb/sRead Intensive1,5

S26361-F5783-E480S26361-F5783-L480

960GB2.5" (SFF)

SATA 6Gb/sRead Intensive1,5

S26361-F5783-E960S26361-F5783-L960

1.92TB2.5" (SFF)

SATA 6Gb/sRead Intensive1,5

S26361-F5783-E192S26361-F5783-L192

3.84TB2.5" (SFF)

SATA 6Gb/sRead Intensive1,2

S26361-F5783-E384S26361-F5783-L384

7.68TB2.5" (SFF)

SATA 6Gb/sRead Intensive0,6

S26361-F5783-E768S26361-F5783-L768

max. 8x, 16x, 24x or 32x - depending on base unit & configuration

L1

2.5" (SFF) Hard drives

EOL, as long as stock available

HDD SAS 2.5"

15K

(SFF) Enterprise Mission Critical with hot plug/hot replace tray

CapacityRPM

InterfaceSectororder code E-partorder code L-part

300GB

15 000SAS 12Gb/s512n

S26361-F5727-E530S26361-F5727-L530

600GB

15 000SAS 12Gb/s512n

S26361-F5727-E560S26361-F5727-L560

900GB

15 000SAS 12Gb/s512n

S26361-F5531-E590S26361-F5531-L590

max. 8x, 16x, 24x or 32x - depending on base unit & configuration

HDD SAS 2.5" 10K 512n

(SFF) Enterprise Mission Critical with hot plug/hot replace tray

CapacityRPM

InterfaceSectororder code E-partorder code L-part

300GB

10 000SAS 12Gb/s512n

S26361-F5729-E130S26361-F5729-L130

600GB

10 000SAS 12Gb/s512n

S26361-F5729-E160S26361-F5729-L160

1.2TB

10 000SAS 12Gb/s512n

S26361-F5729-E112S26361-F5729-L112

300GB

10 000SAS 12Gb/s512n SED

PYBSH301EUPY-SH301EU

600GB

10 000SAS 12Gb/s512n SED

PYBSH601EUPY-SH601EU

1.2TB

10 000SAS 12Gb/s512n SED

PYBSH121EUPY-SH121EU

max. 8x, 16x, 24x or 32x - depending on base unit & configuration

HDD SAS 2.5" 10K 512e

(SFF) Enterprise Mission Critical with hot plug/hot replace tray

CapacityRPM

InterfaceSectororder code E-partorder code L-part

1.8TB

10 000SAS 12Gb/s512e

S26361-F5730-E118S26361-F5730-L118

2.4TB

10 000SAS 12Gb/s512e

S26361-F5543-E124S26361-F5543-L124

1.8TB

10 000SAS 12Gb/s512e SED

PYBSH181DUPY-SH181DU

2.4TB

10 000SAS 12Gb/s512e SED

S26361-F5582-E124S26361-F5582-L124

max. 8x, 16x, 24x or 32x - depending on base unit & configuration

EOL, as long as stock available

HDD SAS 2.5" 7.2K 512n

(SFF) Enterprise Business Critical with hot plug/hot replace tray

CapacityRPM

InterfaceSectororder code E-partorder code L-part

1TB

7 200SAS 12Gb/s512n

S26361-F5600-E100S26361-F5600-L100

2TB

7 200SAS 12Gb/s512n

S26361-F5600-E200S26361-F5600-L200

max. 8x, 16x, 24x or 32x - depending on base unit & configuration

EOL, as long as stock available

HDD SATA 2.5" 7.2K 512n

(SFF) Enterprise Business Critical with hot plug/hot replace tray

CapacityRPM

InterfaceSectororder code E-partorder code L-part

1TB

7 200SATA 6Gb/s512n

S26361-F3956-E100S26361-F3956-L100

2TB

7 200SATA 6Gb/s512n

S26361-F3956-E200S26361-F3956-L200

max. 8x, 16x, 24x or 32x - depending on base unit & configuration

L2

cnfgTX2550M7-20231117__SSDPage 24 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

L2

3.5" (LFF) SATA SSD

will be available in CQ1'24

SSD SATA 3.5" Mixed Use

(LFF) 2.5" SSD Enterprise with 3.5" hot plug/hot replace tray

based on Samsung PM897a drives

CapacityFormfactor

InterfaceEnduranceDWPDorder code E-partorder code L-part

480GB3.5" (LFF)

SATA 6Gb/sMixed Use3 SED

PYBTS48NK9PY-TS48NK9

960GB3.5" (LFF)

SATA 6Gb/sMixed Use3 SED

PYBTS96NK9PY-TS96NK9

1.92TB3.5" (LFF)

SATA 6Gb/sMixed Use3 SED

PYBTS19NK9PY-TS19NK9

3.84TB3.5" (LFF)

SATA 6Gb/sMixed Use3 SED

PYBTS38NK9PY-TS38NK9

This SSDs can be used as Non-SED drives, but it requires a RAID controller with SED support for using as SED drives.

max. 4x, 8x, or 12x - depending on base unit & configuration

SSD SATA 3.5" Mixed Use

(LFF) 2.5" SSD Enterprise with 3.5" hot plug/hot replace tray

based on Samsung PM897 drives

CapacityFormfactor

InterfaceEnduranceDWPDorder code E-partorder code L-part

480GB3.5" (LFF)

SATA 6Gb/sMixed Use3

PYBTS48NK8PY-TS48NK8

960GB3.5" (LFF)

SATA 6Gb/sMixed Use3

PYBTS96NK8PY-TS96NK8

1.92TB3.5" (LFF)

SATA 6Gb/sMixed Use3

PYBTS19NK8PY-TS19NK8

3.84TB3.5" (LFF)

SATA 6Gb/sMixed Use3

PYBTS38NK8PY-TS38NK8

max. 4x, 8x, or 12x - depending on base unit & configuration

SSD SATA 3.5" Mixed Use (LFF)

2.5" SSD Enterprise with 3.5" hot plug/hot replace tray

based on Micron 5300/5400 MAX drives

CapacityFormfactor

InterfaceEnduranceDWPDorder code E-partorder code L-part

480GB2.5" (SFF)

SATA 6Gb/sMixed Use5,0

S26361-F5775-E480S26361-F5775-L480

960GB2.5" (SFF)

SATA 6Gb/sMixed Use5,0

S26361-F5775-E960S26361-F5775-L960

1.92TB2.5" (SFF)

SATA 6Gb/sMixed Use5,0

S26361-F5775-E192S26361-F5775-L192

3.84TB2.5" (SFF)

SATA 6Gb/sMixed Use3,5

S26361-F5775-E384S26361-F5775-L384

max. 4x, 8x, or 12x - depending on base unit & configuration

will be available in CQ1'24

SSD SATA 3.5" Read Intensive (LFF)

2.5" SSD Enterprise with 3.5" hot plug/hot replace tray

based on Samsung PM893a drives

CapacityFormfactor

InterfaceEnduranceDWPDorder code E-partorder code L-part

480GB3.5" (LFF)

SATA 6Gb/sRead Intensive1,0 SED

PYBTS48NMBPY-TS48NMB

960GB3.5" (LFF)

SATA 6Gb/sRead Intensive1,0 SED

PYBTS96NMAPY-TS96NMA

1.92TB3.5" (LFF)

SATA 6Gb/sRead Intensive1,0 SED

PYBTS19NMAPY-TS19NMA

3.84TB3.5" (LFF)

SATA 6Gb/sRead Intensive1,0 SED

PYBTS38NMAPY-TS38NMA

7.68TB3.5" (LFF)

SATA 6Gb/sRead Intensive1,0 SED

PYBTS76NMAPY-TS76NMA

This SSDs can be used as Non-SED drives, but it requires a RAID controller with SED support for using as SED drives.

max. 4x, 8x, or 12x - depending on base unit & configuration

SSD SATA 3.5" Read Intensive (LFF)

2.5" SSD Enterprise with 3.5" hot plug/hot replace tray

based on Samsung PM893 drives

CapacityFormfactor

InterfaceEnduranceDWPDorder code E-partorder code L-part

240GB3.5" (LFF)

SATA 6Gb/sRead Intensive1,0

PYBTS24NM9PY-TS24NM9

480GB3.5" (LFF)

SATA 6Gb/sRead Intensive1,0

PYBTS48NM9PY-TS48NM9

960GB3.5" (LFF)

SATA 6Gb/sRead Intensive1,0

PYBTS96NM9PY-TS96NM9

1.92TB3.5" (LFF)

SATA 6Gb/sRead Intensive1,0

PYBTS19NM9PY-TS19NM9

3.84TB3.5" (LFF)

SATA 6Gb/sRead Intensive1,0

PYBTS38NM9PY-TS38NM9

7.68TB3.5" (LFF)

SATA 6Gb/sRead Intensive1,0

PYBTS76NM9PY-TS76NM9

max. 4x, 8x, or 12x - depending on base unit & configuration

SSD SATA 3.5" Read Intensive (LFF)

2.5" SSD Enterprise with 3.5" hot plug/hot replace tray

based on Micron 5300/5400 PRO drives

CapacityFormfactor

InterfaceEnduranceDWPDorder code E-partorder code L-part

240GB2.5" (SFF)

SATA 6Gb/sRead Intensive1,5

S26361-F5782-E240S26361-F5782-L240

480GB2.5" (SFF)

SATA 6Gb/sRead Intensive1,5

S26361-F5782-E480S26361-F5782-L480

960GB2.5" (SFF)

SATA 6Gb/sRead Intensive1,5

S26361-F5782-E960S26361-F5782-L960

1.92TB2.5" (SFF)

SATA 6Gb/sRead Intensive1,5

S26361-F5782-E192S26361-F5782-L192

3.84TB2.5" (SFF)

SATA 6Gb/sRead Intensive1,2

S26361-F5782-E384S26361-F5782-L384

7.68TB2.5" (SFF)

SATA 6Gb/sRead Intensive0,6

S26361-F5782-E768S26361-F5782-L768

max. 4x, 8x, or 12x - depending on base unit & configuration

cnfgTX2550M7-20231117__SSDPage 25 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

3.5" (LFF) Hard drives

EOL, as long as stock available

HDD SAS 3.5"

15K

(LFF) 2.5" HDD Enterprise Mission Critical with 3.5" hot plug/hot replace tray

CapacityRPM

InterfaceSectororder code E-partorder code L-part

300GB

15 000SAS 12Gb/s512n

S26361-F5726-E530S26361-F5726-L530

600GB

15 000SAS 12Gb/s512n

S26361-F5726-E560S26361-F5726-L560

900GB

15 000SAS 12Gb/s512n

S26361-F5532-E590S26361-F5532-L590

max. 4x, 8x, or 12x - depending on base unit & configuration

HDD SAS 3.5"

10K 512n

(LFF) 2.5" HDD Enterprise Mission Critical with 3.5" hot plug/hot replace tray

CapacityRPM

InterfaceSectororder code E-partorder code L-part

300GB

10 000SAS 12Gb/s512n

S26361-F5728-E130S26361-F5728-L130

600GB

10 000SAS 12Gb/s512n

S26361-F5728-E160S26361-F5728-L160

1.2TB

10 000SAS 12Gb/s512n

S26361-F5728-E112S26361-F5728-L112

max. 4x, 8x, or 12x - depending on base unit & configuration

HDD SAS 3.5"

10K 512e

(LFF) 2.5" HDD Enterprise Mission Critical with 3.5" hot plug/hot replace tray

CapacityRPM

InterfaceSectororder code E-partorder code L-part

1.8TB

10 000SAS 12Gb/s512e

S26361-F5731-E118S26361-F5731-L118

2.4TB

10 000SAS 12Gb/s512e

S26361-F5569-E124S26361-F5569-L124

max. 4x, 8x, or 12x - depending on base unit & configuration

HDD SAS 3.5" 7.2K 512n

(LFF) Enterprise Business critical with hot plug/hot replace tray

CapacityRPM

InterfaceSectororder code E-partorder code L-part

2TB

7 200SAS 12Gb/s512n

PYBCH2T7G4PY-CH2T7G4

4TB

7 200SAS 12Gb/s512n

PYBCH4T7G4PY-CH4T7G4

max. 4x, 8x, or 12x - depending on base unit & configuration

HDD SAS 3.5" 7.2K 512e

(LFF) Enterprise Business Critical with hot plug/hot replace tray

CapacityRPM

InterfaceSectororder code E-partorder code L-part

6TB

7 200SAS 12Gb/s512e

PYBCH6T7B9PY-CH6T7B9

8TB

7 200SAS 12Gb/s512e

S26361-F5635-E800S26361-F5635-L800

12TB

7 200SAS 12Gb/s512e

PYBCHCT7B7PY-CHCT7B7

14TB

7 200SAS 12Gb/s512e

PYBCHET7B6PY-CHET7B6

16TB

7 200SAS 12Gb/s512e

S26361-F5571-E160S26361-F5571-L160

18TB

7 200SAS 12Gb/s512e

PYBCHJT7B2PY-CHJT7B2

20TB

7 200SAS 12Gb/s512eWiil be avairable in CQ1 2024

PYBCHLT7BPY-CHLT7B

6TB

7 200SAS 12Gb/s512e SED

PYBCH6T7BUPY-CH6T7BU

8TB

7 200SAS 12Gb/s512e SED

S26361-F5584-E800S26361-F5584-L800

12TB

7 200SAS 12Gb/s512e SED

PYBCHCT7BWPY-CHCT7BW

14TB

7 200SAS 12Gb/s512e SED

PYBCHET7BVPY-CHET7BV

16TB

7 200SAS 12Gb/s512e SED

S26361-F5624-E160S26361-F5624-L160

18TB

7 200SAS 12Gb/s512e SED

PYBCHJT7BTPY-CHJT7BT

20TB

7 200SAS 12Gb/s512e

FIPS Wiil be avairable in CQ1 2024

PYBCHLT7BSPY-CHLT7BS

max. 4x, 8x, or 12x - depending on base unit & configuration

HDD SATA 3.5" 7.2K 512n

(LFF) Enterprise Business Critical with hot plug/hot replace tray

CapacityRPM

InterfaceSectororder code E-partorder code L-part

1TB

7 200SATA 6Gb/s512n

PYBBH1T7B9PY-BH1T7B9

2TB

7 200SATA 6Gb/s512n

PYBBH2T7B9PY-BH2T7B9

4TB

7 200SATA 6Gb/s512n

PYBBH4T7B9PY-BH4T7B9

max. 4x, 8x, or 12x - depending on base unit & configuration

HDD SATA 3.5" 7.2K 512e

(LFF) Enterprise Business Critical with hot plug/hot replace tray

CapacityRPM

InterfaceSectororder code E-partorder code L-part

6TB

7 200SATA 6Gb/s512e

PYBBH6T7E9PY-BH6T7E9

8TB

7 200SATA 6Gb/s512e

S26361-F5638-E800S26361-F5638-L800

12TB

7 200SATA 6Gb/s512e

PYBBHCT7E4PY-BHCT7E4

14TB

7 200SATA 6Gb/s512e

PYBBHET7E4PY-BHET7E4

16TB

7 200SATA 6Gb/s512e

S26361-F3904-E160S26361-F3904-L160

18TB

7 200SATA 6Gb/s512e

PYBBHJT7E2PY-BHJT7E2

max. 4x, 8x, or 12x - depending on base unit & configuration

L3

cnfgTX2550M7-20231117__SSDPage 26 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

L3

M.2 SATA SSD

M.2 drive for VMware ESXi and for other OSs cannot be mixed

M.2 SATA and M.2 PCIe drive cannot be mixed

SSD SATA M.2 drive for booting, non hot-plug, for VMware ESXi

based on Micron 5300/5400 PRO drives

CapacityFormfactor

InterfaceCategoryorder code E-partorder code L-part

240GBM.2

SATA 6Gb/sBoot

S26361-F5816-E240S26361-F5816-L240

M.2 drive is designed for use as a VMware ESXi boot drive.

max. 1x per Server; in case M.2 drive is installed in connector located on Motherboard (please see folder "description"). VMware ESXi is only supported.

2x M.2 drives required; in case M.2 drives are used with PDUAL CP100 or CP300.

SSD SATA M.2 drive for booting, non hot-plug

based on Micron 5300/5400 PRO drives (960GB is 5400 only)

CapacityFormfactor

InterfaceDWPDCategoryorder code E-partorder code L-part

240GBM.2

SATA 6Gb/s1,5Boot

S26361-F5787-E240S26361-F5787-L240

480GBM.2

SATA 6Gb/s1,5Boot

S26361-F5787-E480S26361-F5787-L480

960GBM.2 2280

SATA 6Gb/s1,5Boot

PYBMF96YNPY-MF96YN

M.2 drive is designed for use as a boot drive with the Endurance Spec. above.

2x M.2 drive for any Hypervisor by the onboard chipset Software RAID is not supported.

max. 2x per Server; in case M.2 drive is installed in connector located on Motherboard (please see folder "description"). VMware is not supported.

2x M.2 drives required; in case M.2 drives are used with PDUAL CP100 or CP300.

SSD PCIe M.2 drive for booting, non hot-plug

based on Micron 7450 PRO drives

CapacityFormfactor

InterfaceDWPDCategoryorder code E-partorder code L-part

480GBM.2 2280

PCIe4.0 x40,9Boot

PYBBS48PEAPY-BS48PEA

960GBM.2 2280

PCIe4.0 x40,9Boot

PYBBS96PEAPY-BS96PEA

M.2 drive is designed for use as a boot drive with the Endurance Spec. above.

max. 2x per Server; connector located on Motherboard (please see folder "description"). 2x M.2 drives require Intel VROC Upgrade Key Premium(PYBRLVR02).

2x M.2 drives required; in case M.2 drives are used with PDUAL CP300.

Dual M.2

PDUAL CP100, PDUAL CP300 and M.2 drive on Motherboard cannot be mixed

PDUAL CP100, dual M.2 for booting, non hot-plug

CapacityFormfactor

InterfaceCategoryorder code E-partorder code L-part

n/aAIC

PCIeBootFH

PYBDMCP24

n/aAIC

PCIeBootLP

PYBDMCP24L

PY-DMCP24

PDUAL CP100 is a carrier of 2x SSD SATA M.2 drives, which offers RAID1 with the 2x SSD M.2 drives.

PDUAL CP100 is designed for use as a hardware-mirrored (RAID1) boot device for Hypervisor, which cannot be supported by M.2 via the onboard chipset Software RAID.

Supported RAID level : RAID1 only, 2x same type of SSD M.2 drives need to be ordered separately.

Supported M.2 drives : SSD SATA M.2 240GB/480GB/960GB or 240GB for VMware ESXi. (S26361-F5787- E240/L240/E480/L480, PY*MF96YN or S26361-F5816-E240/L240)

max. 1x per Server, requires 2x SSD SATA M.2 drives.

PDUAL CP100, PDUAL CP300 and M.2 drive on Motherboard cannot be mixed

PDUAL CP300, dual M.2 for booting, non hot-plug

available from 2024/02

CapacityFormfactor

InterfaceCategoryorder code E-partorder code L-part

n/aAIC

PCIeBootFH

PYBDMCP35

n/aAIC

PCIeBootLP

PYBDMCP35L

PY-DMCP35

PDUAL CP300 is a carrier of 2x SSD SATA or PCIe M.2 drives, which offers RAID1 with the 2x SSD M.2 drives.

PDUAL CP300 is designed for use as a hardware-mirrored (RAID1) boot device for Hypervisor, which cannot be supported by M.2 via the onboard chipset Software RAID.

Supported RAID levels : RAID1 and 0 (optional), 2x same type of SSD M.2 drives need to be ordered separately.

Supported M.2 drives : SSD SATA M.2 240GB/480GB/960GB or 240GB for VMware ESXi. (S26361-F5787- E240/L240/E480/L480, PY*MF96YN or S26361-F5816-E240/L240) or

SSD PCIe M.2 480GB/960GB. (PY*BS48PEA/PY*BS96PEA)

max. 1x per Server, requires 2x SSD M.2 drives.

cnfgTX2550M7-20231117__SSDPage 27 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

2.5" (SFF) PCIe-SSD

hot plug support : supported with VMD

PCIe-SSD 2.5" P5800X

(SFF) Enterprise with hot plug/hot replace tray

based on Intel P5800X drives

CapacityFormfactor

InterfaceEnduranceDWPDorder code E-partorder code L-part

400GB2.5" (SFF)

PCIe4.0 x4Write Intensive100

PYBBS40PFPY-BS40PF

800GB2.5" (SFF)

PCIe4.0 x4Write Intensive100

PYBBS80PFPY-BS80PF

1.6TB2.5" (SFF)

PCIe4.0 x4Write Intensive100

PYBBS16PFPY-BS16PF

max. 8x (4x per CPU) - depending on base unit & configuration

limitation : can not support VROC so farwill be available in CQ4'23

PCIe-SSD 2.5" Mixed Use

(SFF) Enterprise with hot plug/hot replace tray

based on Kioxia CM7-V drives

CapacityFormfactor

InterfaceEnduranceDWPDorder code E-partorder code L-part

1.6TB2.5" (SFF)

PCIe5.0 x4Mixed Use3

PYBBS16PDBPY-BS16PDB

3.2TB2.5" (SFF)

PCIe5.0 x4Mixed Use3

PYBBS32PDBPY-BS32PDB

6.4TB2.5" (SFF)

PCIe5.0 x4Mixed Use3

PYBBS64PDBPY-BS64PDB

12.8TB2.5" (SFF)

PCIe5.0 x4Mixed Use3

PYBBS12PDBPY-BS12PDB

max. 8x (4x per CPU) - depending on base unit & configuration

EOL, as long as stock available

PCIe-SSD 2.5" Mixed Use

(SFF) Enterprise with hot plug/hot replace tray

based on Kioxia CM6-V drives

CapacityFormfactor

InterfaceEnduranceDWPDorder code E-partorder code L-part

1.6TB2.5" (SFF)

PCIe4.0 x4Mixed Use3

PYBBS16PD6PY-BS16PD6

3.2TB2.5" (SFF)

PCIe4.0 x4Mixed Use3

PYBBS32PD6PY-BS32PD6

6.4TB2.5" (SFF)

PCIe4.0 x4Mixed Use3

PYBBS64PD6PY-BS64PD6

12.8TB2.5" (SFF)

PCIe4.0 x4Mixed Use3

PYBBS12PD6PY-BS12PD6

max. 8x (4x per CPU) - depending on base unit & configuration

limitation : can not support VROC so farwill be available in CQ4'23

PCIe-SSD 2.5" Read Intensive

(SFF) Enterprise with hot plug/hot replace tray

based on Kioxia CM7-R drives

CapacityFormfactor

InterfaceEnduranceDWPDorder code E-partorder code L-part

1.92TB2.5" (SFF)

PCIe5.0 x4Read Intensive1

PYBBS19PEAPY-BS19PEA

3.84TB2.5" (SFF)

PCIe5.0 x4Read Intensive1

PYBBS38PEAPY-BS38PEA

7.68TB2.5" (SFF)

PCIe5.0 x4Read Intensive1

PYBBS76PEAPY-BS76PEA

15.36TB2.5" (SFF)

PCIe5.0 x4Read Intensive1

PYBBS15PEBPY-BS15PEB

max. 8x (4x per CPU) - depending on base unit & configuration

EOL, as long as stock available

PCIe-SSD 2.5" Read Intensive

(SFF) Enterprise with hot plug/hot replace tray

based on Kioxia CM6-R drives

CapacityFormfactor

InterfaceEnduranceDWPDorder code E-partorder code L-part

960GB2.5" (SFF)

PCIe4.0 x4Read Intensive1

PYBBS96PE6PY-BS96PE6

1.92TB2.5" (SFF)

PCIe4.0 x4Read Intensive1

PYBBS19PE6PY-BS19PE6

3.84TB2.5" (SFF)

PCIe4.0 x4Read Intensive1

PYBBS38PE6PY-BS38PE6

7.68TB2.5" (SFF)

PCIe4.0 x4Read Intensive1

PYBBS76PE6PY-BS76PE6

15.36TB2.5" (SFF)

PCIe4.0 x4Read Intensive1

PYBBS15PE6PY-BS15PE6

max. 8x (4x per CPU) - depending on base unit & configuration

M

cnfgTX2550M7-20231117__SSDPage 28 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

M

Chapter 11 - LAN Components

FH PCI card requires FH PCI riser. Please refer to ''Chapter 14 - PCI Riser'.

Broadcom 1GbE BEASE-T for PCIe

PLAN CP BCM5719-4P 4X 1000BASE-T PCIe LP6x

PLAN CP BCM5719-4P 4X 1000BASE-T PCIe FH8x

Broadcom, 1GTx4port

PYBLA284L

PYBLA284

PY-LA284

max. 10 adapters per system

Intel 1GbE BASE-T for PCIe

PLAN CP 2x1Gbit Cu Intel I350-T2 LP *1

6x

Intel, 1GTx2port

S26361-F4610-E202S26361-F4610-L502

PLAN CP 4x1Gbit Cu Intel I350-T4 LP6x

Intel, 1GTx4port

S26361-F4610-E204

S26361-F4610-L504

max. 6 adapters per system

*1 Will be available from 2Q, CY2024

Broadcom 10GbE BEASE-T for PCIe

PLAN EP P210TP 2X 10GBASE-T PCIe LP4x

PLAN EP P210TP 2X 10GBASE-T PCIe FH6x

Broadcom, 10GTx2port

PYBLA3K2L

PYBLA3K2

PY-LA3K2

max. 6x adapters per system (must not exceed this number with P210TP and P210P in total and LP cannnot be put on slot#3, slot#10)

Intel 10GbE BASE-T for PCIe

PLAN EP X710-T2L 2X 10GBASE-T LP6xPYBLA342L

PLAN EP X710-T2L 2X 10GBASE-T FH8x

Intel, 10GTx2port

PYBLA342

PY-LA342

PLAN EP X710-T4L 4X 10GBASE-T LP6xPYBLA344L

PLAN EP X710-T4L 4X 10GBASE-T FH8x

Intel, 10GTx4port

PYBLA344

PY-LA344

max. 10x adapters per system

Broadcom 10GbE for PCIe

Each cage consumes 1x optical SFP+ transceiver per port.

Dual rate 10G/1G support requires 10G/1G Dual Rate SFP+ Optical Transceiver Modules.

All ports on this card can install the same Parts Number of optical module.

PLAN EP P210P 2x10Gb SFP PCIe LP4x

PYBLA3J2L

PLAN EP P210P 2x10Gb SFP PCIe FH6x

Broadcom, 10Gx2port

PYBLA3J2

PY-LA3J2

Optional, 10Gb SFP+ optical transceiver module, select one per cage

SFP+ Optical Transceiver 10G Single Rate SR

2x

Finisar, 10G SR SFP+

S26361-F3986-E3S26361-F3986-L3

SFP+ Optical Transceiver 10G/1G Dual Rate

SR

2x

Intel, 1G/10G SR SFP+

S26361-F3986-E5S26361-F3986-L5

SFP+ Optical Transceiver 10G/1G Dual Rate LR

2x

Intel, 1G/10G LR SFP+

S26361-F3986-E6S26361-F3986-L6

max. 1x per port

max. 6x adapters per system (must not exceed this number with P210TP and P210P in total and LP cannnot be put on slot#3, slot#10)

Intel 10GbE for PCIe

Each cage consumes 1x optical SFP+ transceiver per port.

Dual rate 10G/1G support requires 10G/1G Dual Rate SFP+ Optical Transceiver Modules.

All ports on this card can install the same Parts Number of optical module.

PLAN EP X710-DA2 2x10Gb SFP+ LP6xS26361-F3640-E202

PLAN EP X710-DA2 2x10Gb SFP+ FH8x

Intel, 10Gx2port

S26361-F3640-E2

S26361-F3640-L502

PLAN EP X710-DA4 4x10Gb SFP+ LP6xS26361-F3640-E204

PLAN EP X710-DA4 4x10Gb SFP+ FH8x

Intel, 10Gx4port

S26361-F3640-E4

S26361-F3640-L504

Optional, 10Gb SFP+ optical transceiver module, select one per cage

SFP+ Optical Transceiver 10G Single Rate SR

4x

Finisar, 10G SR SFP+

S26361-F3986-E3S26361-F3986-L3

SFP+ Optical Transceiver 10G/1G Dual Rate

SR

4x

Intel, 1G/10G SR SFP+

S26361-F3986-E5S26361-F3986-L5

SFP+ Optical Transceiver 10G/1G Dual Rate LR

4x

Intel, 1G/10G LR SFP+

S26361-F3986-E6S26361-F3986-L6

max. 1x per port

max. 10x adapters per system

Broadcom 25GbE for PCIe

Each cage consumes 1x optical SFP28.

All ports on this card can install the same Parts Number of optical module.

10G SFP BTO is not available for 25G cards, please select L parts.

PLAN EP P225P 25Gb 2p SFP28 PCIe LP *1

6x

PYBLA3H2L

PLAN EP P225P 25Gb 2p SFP28 PCIe FH *1

8x

Broadcom, 25Gx2port

PYBLA3H2

PY-LA3H2

Optional, 25Gb SFP28 optical transceiver module, select one per cage

SFP28 25G SR E25GSFP28SRX LC

2x

Intel, 25G SR SFP28PYBSFPS56PY-SFPS56

max. 1x per port

Optional, 10Gb SFP+ optical transceiver module, select one per cage

SFP+ Optical Transceiver 10G/1G Dual Rate

SR

2x

Intel, 1G/10G SR SFP+

S26361-F3986-E5S26361-F3986-L5

SFP+ Optical Transceiver 10G/1G Dual Rate LR

2x

Intel, 1G/10G LR SFP+

S26361-F3986-E6S26361-F3986-L6

max. 1x per port

max. 10x adapters per system

*1 Will be available from 1Q, CY2024

cnfgTX2550M7-20231117_NPage 29 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

NVIDIA 25GbE for PCIe

Each cage consumes 1x optical SFP28.

All ports on this card can install the same Parts Number of optical module.

10G SFP BTO is not available for 25G cards, please select L parts.

Ethernet Network Adapters

PLAN EP MCX6-LX 25Gb 2p SFP28 PCIe LP *1

6x

PYBLA402L4

PLAN EP MCX6-LX 25Gb 2p SFP28 PCIe FH *1

8x

NVIDIA, 25Gx2port

PYBLA4024

PY-LA4024

Optional, 25Gb SFP28 optical transceiver module, select one per cage

SFP28 25G SR E25GSFP28SRX LC

2x

Intel, 25G SR SFP28PYBSFPS56PY-SFPS56

SFP28 Optical Transceiver 25G SR MMA2P00-

AS LC

2x

NVIDIA, 25G SR SFP28S26361-F4054-E701S26361-F4054-L701

max. 1x per port

Optional, 10Gb SFP+ optical transceiver module, select one per cage

SFP+ Optical Transceiver 10G/1G Dual Rate

SR

2x

Intel, 1G/10G SR SFP+

S26361-F3986-E5S26361-F3986-L5

SFP+ Optical Transceiver 10G/1G Dual Rate LR

2x

Intel, 1G/10G LR SFP+

S26361-F3986-E6S26361-F3986-L6

max. 1x per port

max. 10x adapters per system

*1 Will be available from 1Q, CY2024

Intel 25GbE for PCIe

Each cage consumes 1x optical SFP28.

All ports on this card can install the same Parts Number of optical module.

10G SFP BTO is not available for 25G cards, please select L parts.

PLAN EP E810-XXVDA2 2X 25G SFP28 LP6x

PLAN EP E810-XXVDA2 2X 25G SFP28 FH8x

Intel, 25Gx2port

PYBLA402L

PYBLA402

PY-LA402

PLAN EP E810-XXVDA4 4X 25G SFP28 LP

6x

Intel, 25Gx4port

PYBLA404L

PY-LA404

Optional, 25Gb SFP28 optical transceiver module, select one per cage

SFP28 25G SR E25GSFP28SRX LC

4x

Intel, 25G SR SFP28

PYBSFPS56PY-SFPS56

max. 1x per port

Optional, 10Gb SFP+ optical transceiver module, select one per cage

SFP+ Optical Transceiver 10G/1G Dual Rate

SR

4x

Intel, 1G/10G SR SFP+

S26361-F3986-E5S26361-F3986-L5

SFP+ Optical Transceiver 10G/1G Dual Rate LR

4x

Intel, 1G/10G LR SFP+

S26361-F3986-E6S26361-F3986-L6

max. 1x per port

max. 10x adapters per system(E810-XXVDA2) / max. 6x adapters per system(E810-XXVDA4)

Broadcom 100GbE for PCIe

Each cage consumes 1x optical QSFP28

All ports on this card can install the same Parts Number of optical module.

PLAN EP P2100G 100Gb 2p QSFP56 PCIe LP *16xBroadcom, 100Gx2portPYBLA442LPY-LA442

PLAN EP P2100G 100Gb 2p QSFP56 PCIe FH *14xBroadcom, 100Gx2portPYBLA442PY-LA442

Optional, 100Gb QSFP28 Optical Transceiver module

QSFP28 100G SR4 E100GQSFP28SRX MPO

2x

Intel, 100G SR4 QSFP28PYBSFPS54PY-SFPS54

QSFP28 100G SR4 MPO 850nm 100m

MMA1B00-C100D

2x

NVIDIA, 100G SR4 QSFP28S26361-F4052-E701S26361-F4052-L701

max. 1x per port

max. 6x adapters per system

*1 Will be available from 1Q, CY2024

Intel 100GbE for PCIe

Each cage consumes 1x optical QSFP28.

The QSFP will not ship on the card because it will interfere with the shipping box.

All ports on this card can install the same Parts Number of optical module.

PLAN EP E810-CQDA2 2X 100G QSFP28 LP6x

Intel, 100Gx2portPYBLA432LPY-LA432

Optional, 100Gb QSFP28 Optical Transceiver module

QSFP28 100G SR4 E100GQSFP28SRX MPO

2x

Intel, 100G SR4 QSFP28PYBSFPS54PY-SFPS54

max. 1x per port

max. 6x adapters per system

NVIDIA 100GbE for PCIe

Each cage consumes 1x optical QSFP28

The QSFP will not ship on the card because it will interfere with the shipping box.

All ports on this card can install the same Parts Number of optical module.

PLAN EP MCX6-DX 2X 100G QSFP28 LP6x

NVIDIA, 100Gx2portPYBLA412LPY-LA412

Optional, 100Gb QSFP28 Optical Transceiver module

QSFP28 100G SR4 MPO 850nm 100m

MMA1B00-C100D

2x

NVIDIA, 100G SR4 QSFP28

S26361-F4052-E701S26361-F4052-L701

max. 1x per port

max. 6x adapters per system

N

Network cables for later upgrade

O

cnfgTX2550M7-20231117_NPage 30 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

Chapter 12 - Fibre Channel Controller

O

FH PCIe card requires FH PCIe riser card. Please refer to ''Chapter 14 - PCI riser card'.

max number of some controllers can vary with base units with 6x card slots

64G Fibre Channel adapters with LC interface for 50µm optical cables (OM4 or OM3)

PFC EP LPe36000 1X 32GFC PCIe v4 LP6x

Broadcom, 64GFCx1port

PFC EP LPe36000 1X 32GFC PCIe FH8x

PFC EP LPe36002 2X 32GFC PCIe v4 LP6x

Broadcom, 64GFCx2port

PFC EP LPe36002 2X 32GFC PCIe v4 FH8x

6x

PFC EP QLE2870 1X 32GFC PCIe v4 LP

Marvell, 64GFCx1port

PFC EP QLE2870 1X 32GFC PCIe v4 FH 8x

PFC EP QLE2872 2X 32GFC PCIe v4 LP 6x

Marvell, 64GFCx2port

PFC EP QLE2872 2X 32GFC PCIe v4 FH 8x

32G Fibre Channel adapters with LC interface for 50µm optical cables (OM4 or OM3)

PFC EP LPe35000 1X 32GFC PCIe v4 LP6x

Broadcom, 32GFCx1port

PFC EP LPe35000 1X 32GFC PCIe v4 FH8x

PFC EP LPe35002 2X 32GFC PCIe v4 LP6x

Broadcom, 32GFCx2port

PFC EP LPe35002 2X 32GFC PCIe v4 FH8x

PFC EP QLE2770 1X 32GFC PCIe v4 LP6x

Marvell, 32GFCx1port

PFC EP QLE2770 1X 32GFC PCIe v4 FH8x

PFC EP QLE2772 2X 32GFC PCIe v4 LP6x

Marvell, 32GFCx2port

PFC EP QLE2772 2X 32GFC PCIe v4 FH 8x

16G Fibre Channel adapters with LC interface for 50µm optical cables (OM4 or OM3)

PFC EP LPe31000 1x 16Gb LP6x

Broadcom, 16GFCx1port

PFC EP LPe31000 1x 16Gb FH8x

PFC EP LPe31002 2x 16Gb LP6x

Broadcom, 16GFCx2port

PFC EP LPe31002 2x 16Gb FH8x

PFC EP QLE2690 1x 16Gb LP6x

Marvell, 16GFCx1port

PFC EP QLE2690 1x 16Gb FH8x

PFC EP QLE2692 2x 16Gb LP6x

Marvell, 16GFCx2port

PFC EP QLE2692 2x 16Gb FH8x

max. 10 adapters per system

PYBFC441L

PYBFC441

PYBFC442L

PYBFC442

PYBFC431L

PYBFC431

PYBFC432L

PYBFC432

PYBFC421L

PYBFC421

PYBFC422L

PYBFC422

PYBFC411L

PYBFC411

PYBFC412L

PYBFC412

S26361-F5596-E201

S26361-F5596-E1

S26361-F5596-E202

S26361-F5596-E2

S26361-F5580-E201

S26361-F5580-E1

S26361-F5580-E202

S26361-F5580-E2

PY-FC441

PY-FC442

PY-FC431

PY-FC432

PY-FC421

PY-FC422

PY-FC411

PY-FC412

S26361-F5596-L501

S26361-F5596-L502

S26361-F5580-L501

S26361-F5580-L502

Chapter 13 - Infiniband Controllers

Infinibandand Omni path controller will not be released.

P

cnfgTX2550M7-20231117__IBPage 31 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

Chapter 14 - PCI riser card

PCI riser card configuration

Standard Model only(PYT2557TAN/PYT2557TBN/PYT2557TCN

/PYT2557R3N/PYT2557R2N/PYT2557RAN)

6x PCIe slots are on board, with optional PCIe riser card up to 10x PCIe slots are available.

You can choose between 6 different PCI riser card (Options a – f), depending on the selected PCIe card or GPGPU.

Please refer to the tables below for more details and for the installation rules.

Required 'Configuration Thermal Design 30°C(CTD30)[PYBETA1]'

P

Full height PCIe card

A100, A30, A16, L40

or x16 PCIe card

is selected

Details of each PCIe riser card option (a – f) are described on the following pages

T400 4GB, A2, L4,

RTX A6000, RTX

A4500, RTX 6000

or x16 PCIe card

is selected

T400 4GB

or x8 PCIe card

is selected

Option c)

Full height 4slot PCIe riser card

(x8 Gen4)

A100, A30, A16, L40,

,H100

or x16 PCIe card

is selected

T400 4GB, A2, L4,

RTX A6000, RTX

A4500, RTX 6000

or x16 PCIe card

is selected

T400 4GB

or x8 PCIe card

is selected

Option f)

Full height 4slot PCIe riser card

(x8 Gen5)

with retimer

Option a)

Full height 2slot PCIe riser card

(x16 Gen4)

with PCIe support bracket

Option d)

Full height 2slot PCIe riser card

(x16 Gen5)

with PCIe support bracket

with retimer

Option b)

Full height 2slot PCIe riser card

(x16 Gen4)

without PCIe support bracket

Option e)

Full height 2slot PCIe riser card

(x16 Gen5)

without PCIe support bracket

with retimer

Q

Possible configurations with each PCIe riser card option

*Support brackets are required for the cooling of passively cooled FH GPUs.

cnfgTX2550M7-20231117_I_riser_cardPage 32 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

Option a) Full height 2slot PCIe riser card (x16 Gen4) with PCIe support bracket

If the below 2 options are selected, 6x PCIe slots (LP/ x16) change to 2x PCIe slots (LP/ x16) + 4x PCIe slots (FH/ x16).

PCIe cards and double width GPGPUs can be supported on 4x PCIe slots (FH/ x16).

One full height GPGPU can be installed on 1x PCIe slot (FH/ x16).

Support brackets are required for the cooling of passively cooled FH GPUs.“

A100, A30, A16, L40 and / or FH PCIe card is selected

Full height 2slot PCIe riser card right (CPU 1) with PCIe support bracket

PYBPRE638 / PY-PRE638

x16 Gen4 PCIe riser card

Note:

With this card, 3x PCIe slots (LP/ x16) change to 1x PCIe slots (LP/ x16) + 2x PCIe slots (FH/ x16).

Please refer to ‘Chapter 5 – Graphics cards’ for more details about the supported GPGPUs’.

Please refer to chapter ‘Thermal’ for more details about limitations’.

Full height 2slot PCIe riser card left (CPU 2) with PCIe support bracket

PYBPRE639 / PY-PRE639

x16 Gen4 PCIe riser card

Note:

2nd CPU is needed.

With this card, 3x PCIe slots (LP/ x16) change to 1x PCIe slots (LP/ x16) + 2x PCIe slots (FH/ x16).

Please refer to ‘Chapter 5 – Graphics cards’ for more details about the supported GPGPUs'.

Option b) Full height 2slot PCIe riser cards (x16 Gen4) without PCIe support bracket

If the below 2 options are selected, 6x PCIe slots (LP/ x16) change to 2x PCIe slots (LP/ x16) + 4x PCIe slots (FH/ x16).

PCIe cards and double width GPGPUs can be supported on 4x PCIe slots (FH/ x16).

One full height GPGPU can be installed on 1x PCIe slot (FH/ x16).

T400 4GB, A2, L4, RTX A6000, RTX A4500, RTX 6000 and / or FH PCIe card is selected

Full height 2slot PCIe riser card right (CPU 1) without PCIe support bracket

PYBPRE641 / PY-PRE641

x16 Gen4 PCIe riser card

Note:

With this card, 3x PCIe slots (LP/ x16) change to 1x PCIe slots (LP/ x16) + 2x PCIe slots (FH/ x16).

Please refer to ‘Chapter 5 – Graphics cards’ for more details about the supported GPGPUs’.

Please refer to chapter ‘Thermal’ for more details about limitations’.

Full height 2slot PCIe riser card left (CPU 2) without PCIe support bracket

PYBPRE642 / PY-PRE642

x16 Gen4 PCI Riser

Note:

2nd CPU is needed.

With this card, 3x PCIe slots (LP/ x16) change to 1x PCIe slots (LP/ x16) + 2x PCIe slots (FH/ x16).

Please refer to ‘Chapter 5 – Graphics cards’ for more details about the supported GPGPUs'.

Option c) Full height 4slot PCIe riser card (x8 Gen4)

If the below 2 options are selected, 6x PCIe slots (LP/ x16) change to 2x PCIe slots (LP/ x16) + 8x PCIe slots (FH/ x8).

GPGPU(Double height) cannot be supported.

T400 4GB and / or FH PCIe card is selected

Full height 4slot PCIe riser card right (CPU1)

PYBPRE848 / PY-PRE848

x8 Gen4 PCIe riser card

Note:

With this card, 3x PCIe slots (LP/ x16) change to 1x PCIe slots (LP/ x16) + 4x PCIe slots (FH/ x8).

Please refer to ‘Chapter 5 – Graphics cards’ for more details about the supported GPGPUs’.

Please refer to chapter ‘Thermal’ for more details about limitations’.

Full height 4slot PCIe riser card left (CPU2)

PYBPRE849 /PY-PRE849

x8 Gen4 PCI Riser

Note:

2nd CPU is needed

With this card, 3x PCIe slots (LP/ x16) change to 1x PCIe slots (LP/ x16) + 4x PCIe slots (FH/ x8).

Please refer to ‘Chapter 5 – Graphics cards’ for more details about the supported GPGPUs’.

cnfgTX2550M7-20231117_I_riser_cardPage 33 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

Option d) Full height 2slot PCIe riser card (x16 Gen5) with PCIe support bracket with Retimer

If the below 2 options are selected, 6x PCIe slots (LP/ x16) change to 2x PCIe slots (LP/ x16) + 4x PCIe slots (FH/ x16).

PCIe cards and double width GPGPUs can be supported on 4x PCIe slots (FH/ x16).

One full height GPGPU can be installed on 1x PCIe slot (FH/ x16).

Support brackets are required for the cooling of passively cooled FH GPUs.“

A100, A30, A16, L40, H100 and / or FH PCIe card is selected

Full height 2slot PCIe riser card right (CPU 1) with PCIe support bracket with Retimer

PYBPRE643 / PY-PRE643

x16 Gen5 PCI riser card

Note:

With this card, 3x PCIe slots (LP/ x16) change to 1x PCIe slots (LP/ x16) + 2x PCIe slots (FH/ x16).

Please refer to ‘Chapter 5 – Graphics cards’ for more details about the supported GPGPUs’.

Please refer to chapter ‘Thermal’ for more details about limitations’.

Full height 2slot PCIe riser card left (CPU 2) with PCIe support bracket with Retimer

PYBPRE644 / PY-PRE644

x16 Gen5 PCI riser card

Note:

2nd CPU is needed.

With this card, 3x PCIe slots (LP/ x16) change to 1x PCIe slots (LP/ x16) + 2x PCIe slots (FH/ x16).

Please refer to ‘Chapter 5 – Graphics cards’ for more details about the supported GPGPUs'.

Option e) Full height 2slot PCIe riser card (x16 Gen5) without PCIe support bracket with Retimer

If the below 2 options are selected, 6x PCIe slots (LP/ x16) change to 2x PCIe slots (LP/ x16) + 4x PCIe slots (FH/ x16).

PCIe cards and double width GPGPUs can be supported on 4x PCIe slots (FH/ x16).

One full height GPGPU can be installed on 1x PCIe slot (FH/ x16).

T400 4GB, A2, L4, RTX A6000, RTX A4500, RTX 6000 and / or FH PCIe card is selected

Full height 2slot PCIe riser card right (CPU 1) without PCIe support bracket with Retimer

PYBPRE645 / PY-PRE645

x16 Gen5 PCI riser card

Note:

With this card, 3x PCIe slots (LP/ x16) change to 1x PCIe slots (LP/ x16) + 2x PCIe slots (FH/ x16).

Please refer to ‘Chapter 5 – Graphics cards’ for more details about the supported GPGPUs’.

Please refer to chapter ‘Thermal’ for more details about limitations’.

Full height 2slot PCIe riser card left (CPU 2) without PCIe support bracket with Retimer

PYBPRE646 / PY-PRE646

x16 Gen5 PCI riser card

Note:

2nd CPU is needed.

With this card, 3x PCIe slots (LP/ x16) change to 1x PCIe slots (LP/ x16) + 2x PCIe slots (FH/ x16).

Please refer to ‘Chapter 5 – Graphics cards’ for more details about the supported GPGPUs'.

Option f) Full height 4slot PCIe riser card (x8 Gen5) with Retimer

If the below 2 options are selected, 6x PCIe slots (LP/ x16) change to 2x PCIe slots (LP/ x16) + 8x PCIe slots (FH/ x8).

GPGPU(Double height) cannot be supported.

T400 4GB and / or FH PCIe card is selected

Full height 4slot PCIe riser card right (CPU1) with Retimer

PYBPRE851 / PY-PRE851

x8 Gen5 PCI riser card

Note:

With this card, 3x PCIe slots (LP/ x16) change to 1x PCIe slots (LP/ x16) + 4x PCIe slots (FH/ x8).

Please refer to ‘Chapter 5 – Graphics cards’ for more details about the supported GPGPUs’.

Please refer to chapter ‘Thermal’ for more details about limitations’.

Full height 4slot PCIe riser card left (CPU2) with Retimer

PYBPRE852 / PY-PRE852

x8 Gen5 PCI riser card

Note:

2nd CPU is needed

With this card, 3x PCIe slots (LP/ x16) change to 1x PCIe slots (LP/ x16) + 4x PCIe slots (FH/ x8).

Please refer to ‘Chapter 5 – Graphics cards’ for more details about the supported GPGPUs’.

cnfgTX2550M7-20231117_I_riser_cardPage 34 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

Chapter 15 - Power supply unit, power cable, certifications, region kits

R

Power supply unit

modular redundant Power Supply

2nd PSU for redundancy basically.

occupies hot plug PSU slot, min. 1 / max. 2x per system. The different PSU mixed configuration does NOT support.

input nominal voltage (AC): 100V-240V, max: 90V-264V; input dropout 10ms/100% load, 47Hz-63Hz

500W platinum PSU

94% eff. Connector type: C13, APAC/JAPAN region only

PYBPU501PY-PU501

500W titanium PSU

96% eff. Connector type: C13, nom. 220-240V, max. 180-264V

PYBPU503PY-PU503

900W platinum PSU

94% eff. Connector type: C13, APAC/JAPAN region only

PYBPU902PY-PU902

900W titanium PSU

96% eff. nom. 220-240V, max. 180-264V

PYBPU901PY-PU901

1600W platinum PSU

94% eff. Connector type: C13, APAC/JAPAN region only

PYBPU163PY-PU163

1600W titanium PSU

96% eff. Connector type: C13, nom. 220-240V, max. 180-264V

PYBPU165PY-PU165

2200W platinum PSU

94% eff. Connector type: C19 200~240V only, APAC/JAPAN region only

PYBPU221PY-PU221

2400W Titanium PSU

96% eff. Connector type: C19, nom. 220-240V, max. 180-264V

PYBPU243PY-PU243

Dummy module instead PSU

Dummy module for closing the 2nd PSU hole, in case only 1 PSU is equipped, max. 1x per systemPYBDMP06-

If Power consumption error occureson 2400W PSU, 'No Redundant' can be selected

PYBVS002

No Power redundant option

If this option is selected, the system may shutdown at the worst case

Note: 2x 1600W or 2x 2200W or 2x 2400W are mandatory.

in one PSU failure. Not allow activity exchange for PSU even if

If Power budget isn't enough even if 2400W PSU is used, it can be used.

two PSU are selected.

max. 1x per system

Power cord option for Tower Server, 1x per PSU

Cable powercord (USA) 15A, 1.8m, black, NEMA 5-15 connector 498G -> C13 (plug), 15A, , rack or wall

T26139-Y1741-E90T26139-Y1741-L90

Cable powercord (Taiwan), 1.8m, rack or wall

T26139-Y1757-E10T26139-Y1757-L10

Cable powercord (D, A, B, F, NL, FIN, N, S, E, P, RUS, TR), 1.8m, grey

T26139-Y1740-E10T26139-Y1740-L10

Cable powercord (China), 1.8m, grey

T26139-Y1743-E10-

Cable powercord (China), 1.8m, black

-T26139-Y1751-L10

Cable powercord (UK, IR), 1.8m, grey

T26139-Y1744-E10T26139-Y1744-L10

Cable powercord (I), 1.8m, grey

T26139-Y1745-E10T26139-Y1745-L10

Cable powercord (DK), 1.8m, grey

T26139-Y1746-E10T26139-Y1746-L10

Cable powercord (ISR), 2.5m, black

T26139-Y1747-E18T26139-Y1747-L18

2200w or more

Power cord 16A IEC320 C19->CEE 7/7, 2.5m for 2200W/2400W PSU

S26361-F3151-L100

Power cord 16A IEC320 C19->C20, 3.5m for 2200W/2400W PSU

S26361-F3151-E300S26361-F3151-L300

Power cord IEC320 C19 -> US NEMA L6-20p, 4m for 2200W/2400W PSU

S26361-F3151-E500S26361-F3151-L500

common

no power cord

T26139-Y3850-E10

Power cord option for Rack Server, 1x per PSU

Cable powercord rack, 1.8m, black, IEC 320 C14 -> C13 (10A plug)

T26139-Y1968-E180T26139-Y1968-L180

Cable powercord rack, 2.5m, black, IEC 320 C14 -> C13 (10A plug)

T26139-Y1968-E250T26139-Y1968-L250

Cable powercord rack, 4m, black, IEC 320 C14 -> C13 (10A plug)

T26139-Y1968-E100T26139-Y1968-L10

Cable powercord (USA) 15A, 1.8m, black, NEMA 5-15 connector 498G -> C13 (plug), 15A, , rack or wall

T26139-Y1741-E90T26139-Y1741-L90

Cable powercord (Taiwan), 1.8m, rack or wall

T26139-Y1757-E10T26139-Y1757-L10

Cable powercord (D, A, B, F, NL, FIN, N, S, E, P, RUS, TR), 1.8m, grey

T26139-Y1740-E10T26139-Y1740-L10

Cable powercord (China), 1.8m, grey

T26139-Y1743-E10-

Cable powercord (China), 1.8m, black

-T26139-Y1751-L10

Cable powercord (UK, IR), 1.8m, grey

T26139-Y1744-E10T26139-Y1744-L10

Cable powercord (I), 1.8m, grey

T26139-Y1745-E10T26139-Y1745-L10

Cable powercord (DK), 1.8m, grey

T26139-Y1746-E10T26139-Y1746-L10

Cable powercord (ISR), 2.5m, black

T26139-Y1747-E18T26139-Y1747-L18

2200w or more

Power cord 16A IEC320 C19->CEE 7/7, 2.5m for 2200W/2400W PSU

S26361-F3151-L100

Power cord 16A IEC320 C19->C20, 3.5m for 2200W/2400W PSU

S26361-F3151-E300S26361-F3151-L300

Power cord IEC320 C19 -> US NEMA L6-20p, 4m for 2200W/2400W PSU

S26361-F3151-E500S26361-F3151-L500

common

no power cord

T26139-Y3850-E10

One region kit mandatory

S26361-F1452-E100S26361-F1452-E101S26361-F1452-E130S26361-F1452-E140

REGION KIT APAC/EMEARegion Kit China for CCCREGION KIT AmericaREGION KIT Europe

For Shipments to Asia pacific, Contains warranty sheet and For Shipments to America

America, EMEA regionssafety instructions for China, regions

need to be included always into

the order from China country

1x per system1x per system1x per system1x per system

S26361-F3301-E120

Certification for China, (CCC)

Certification for China, (CCC), Reduced component

selection possible, only with no power cord option

1x per system

S

cnfgTX2550M7-20231117_UPage 35 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

Chapter 16 - Accessories

S

USB Mouse:

Mouse M520 Black

n/aS26381-K467-L100

Mouse M520 Greyn/a

S26381-K467-L101

Mouse M530 Blackn/aS26381-K468-L100

Mouse M530 Greyn/aS26381-K468-L101

USB Keyboards for Tower Servers for following countries:

Country versionFUJITSU Keyboard KB521 USB (grey)

US/ int 105 keys (UK keyboard + US int. Layout)S26381-K521-L102

Czech/SlovakS26381-K521-L104

US 104 keys (US keyboard + US layout)S26381-K521-L110

GermanyS26381-K521-L120

Germany / IntS26381-K521-L122

FranceS26381-K521-L140

Sweden / FinlandS26381-K521-L154

United KingdomS26381-K521-L165

SwitzerlandS26381-K521-L170

SpainS26381-K521-L180

ItalyS26381-K521-L185

USB Optical Disc Drive

External Ultra Slim Portable DVD Writer (Hitachi-LG)

S26341-F103-L142

T

cnfgTX2550M7-20231117_B devicesPage 36 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

Chapter 17 - Energy Star

T

will be expired after 2024-1-11will be expired after 2024-1-11will be effective after 2024-1-12will be effective after 2024-1-12

S26361-F3301-E551S26361-F3301-E552PYBES26PYBES27

TX2550 Mx E-Star Fam1TX2550 Mx E-Star Fam2TX2550 Mx E-Star Fam1TX2550 Mx E-Star Fam2

Limits configuration in accordance Limits configuration in accordance Limits configuration in accordance Limits configuration in accordance

with Energy Star requirements for systems with 1 CPUwith Energy Star requirements for systems with 2 CPUwith Energy Star requirements for systems with 1 CPUwith Energy Star requirements for systems with 2 CPU

max. 1x per systemmax. 1x per systemmax. 1x per systemmax. 1x per system

1 CPU Variant1 CPU Variant

notallowed are:

limitations for E-Star Fam1certification

2 CPU Variant

notallowed are:

limitations for E-Star Fam2certification

notallowed are:

limitations for E-Star Fam1certification

2 CPU Variant

notallowed are:

limitations for E-Star Fam2certification

-2 CPU configuration

-1 CPU configuration

-2 CPU configuration

-1 CPU configuration

-CPU Xeon Bronze 3408U

-CPU Xeon Bronze 3408U

-CPU Xeon Bronze 3408

-CPU Xeon Silver 4410Y

-CPU Xeon Silver 4410Y

-CPU Xeon Silver 4416+

-CPU Xeon Silver 4416+

-CPU Xeon Gold 5415+

-CPU Xeon Gold 5415+

-CPU Xeon Gold 6426Y

-CPU Xeon Gold 6426Y

-CPU Xeon Gold 6434

-CPU Xeon Gold 6434

-CPU Xeon platinum 8444H

-CPU Xeon platinum 8444H

-CPU Xeon Gold 5416S

-CPU Xeon Gold 5416S

-CPU Xeon Silver 4410T

-CPU Xeon Silver 4410T

-900W platinum PSU

-900W platinum PSU

-1600W platinum PSU

-1600W platinum PSU

-2200W platinum PSU

-2200W platinum PSU

ENERGY STAR-configurations with one CPU will be labeled:

PRIMERGY TX2550 M7 E-Star Fam1

ENERGY STAR-configurations with two CPU will be labeled:

PRIMERGY TX2550 M7 E-Star Fam2

non ENERGY STAR-configurationen will be labeled:

PRIMERGY TX2550 M7

U

cnfgTX2550M7-20231117_ergy StarPage 37 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

Chapter 18 - others (ErP Lot 9 restriction)

U

*Region kit Europe must be orderd for

shipment toship in EU and EFTA

Region Kits, 1x per System

Region Kit APAC/EMEA/India,

Contains warranty sheet and safety instructions

for APAC, EMEA and India

Region Kit America,

Contains warranty sheet, registration hints and

safety instructions for America

S26361-F1452-E100

Region Kits, 1x per System

Region Kit Europe*,

Contains warranty sheet and safety instructions

in German, English, French, Spanish, Italian,

Polish, Russian and Welsh language

S26361-F1452-E140

S26361-F1452-E130

Restriction for ErP Lot 9 directive,

Not allowed: (For all base unit)

- 500W platinum PSU

- 900W platinum PSU

- 1600W platinum PSU

- 2200W platinum PSU

need to select one of PYBETL17 or PYBETL18

ErP Lot9 Restriction for 16GB DIMM, 1x per System

For 2.5" base unit only

2.5" base unit: PYT2557T2N, PYT2557TBN, PYT2557TCN, PYT2557R2N,

PYT2557RAN

Erp Lot9 configuration 1

PYBETL17

ErP Lot9 Restriction for >=32GB DIMM, 1x per System

For all 3.5", 2.5" base unit

3.5" base unti: PYT2557T3N, PYT2557TAN, PYT2557R3N

2.5" base unit: PYT2557T2N, PYT2557TBN, PYT2557TCN, PYT2557R2N,

PYT2557RAN

ErP Lot 9 configuration 2

PYBETL18

Restriction for ErP Lot9 directive,

* this option is NOT avaialble for 3.5" base unit.

(For PYT2557T2N, PYT2557TBN, PYT2557TCN, PYT2557R2N,

PYT2557RAN)

Not allowed:

-CPU: Bronze 3408U (PYBCP65XR)

-NVIDIAT400 (PYBVG4T2L)

-NVMe SSD (PYBBA24PJ, PYBBA24PK, PYBCBE024,

PYBCBE025)

Max qty of 1G LAN card restricted to max. 2

1G LAN: S26361-F4610-E204, PYBLA284L, PYBLA284

Restriction for ErP Lot9 directive,

(For PYT2557T3N, PYT2557TAN, PYT2557R3N,

PYT2557T2N, PYT2557TBN, PYT2557TCN, PYT2557R2N,

PYT2557RAN)

Not allowed:

-CPU: Bronze 3408U (PYBCP65XR)

-DIMM: 16GB DIMM (PYBME16SL)

V

cnfgTX2550M7-20231117_P Lot9Page 38 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

Chapter 19 - others

V

PYBRMC44

PY-RMC44

iRMC advanced pack

integrated remote Management controller activation key for graphical

console redirection and remote media redirection

max. 1x per system

PYBLCM14

embedded Lifecycle Management (eLCM)Loose delivery

Server Online UpdateeLCM Activation Pack

OS driver Update(Node Locked License)

Hardware firmware updatePY-LCM14

Server Offline Updateoptions contains:

Hardware update via Update Manager Express- Paper with TAN for Licensekey

PrimeCollect

Autonomous creation of Primecollect archives

Custom Image (Jukebox function)

Automatic and manual download of CD and DVD Images

Automatic and manual start of CD and DVD Images

max. 1x per system

PYBSSS3

iRMC standard/legacy Option

When this product is orderd, following iRMC default setting is changed.

Unique default password: No. The fixed password is printed on ID tag.

SSH: Enabled

USB Host LAN : Enabled

Force to change default pwd to use Redfish/RESTful/other interfaces: No

max. 1x per system

PY TX2550 M7 Tower 4x3.5' basic and PY

Advanced Thermal Designis not available with LTO drives.

TX2550 M7 Tower 8x2.5' basic do not support

ATD options! For the detail, refer to the 'Therma

chapter'.

S26361-F3776-E440S26361-F3776-E445

Cool-safe ® Advanced Thermal design 40°CCool-safe ® Advanced Thermal design 45°C

enables the PRIMERGY Server to cope with enables the PRIMERGY Server to cope with temperatures from

temperatures from 5-40° in operating mode due to 5-45° in operating mode due to extended Fan settings

extended Fan settings

this setting can be activated ex factory onlythis setting can be activated ex factory only

max. 1x per systemmax. 1x per system

PYBETA1

Configuration Thermal Design 30°C(CTD30)

Sets the PRIMERGY server to support temperatures of up to

30 ° C in operating mode for the configuration with thermal

restriction.

Refer to Chapter15-Thermal Rule

this setting can be activated ex factory only

max. 1x per system

cnfgTX2550M7-20231117_hersPage 39 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

PYBCOM08

PY-COM08

Serial Port Option

RS-232-C for a RS-232-C Serial Port Interface

does NOT occupy PCI slot

max. 1x per system

PYBVAP08

PY-VAP08

Front VGA Option

VGA Interface

does NOT occupy PCI slot

max. 1x per system

will be EOL in CQ2'24

PYBTPM14

PY-TPM14

TPM 2.0 Module SPI

required for Microsoft Windows Server 2022 (host OS)

max. 1x per system

will be available in CQ1'24

PYBTPM20

PY-TPM20

TPM 2.0 Module V2

required for Microsoft Windows Server 2022 (host OS)

max. 1x per system

PYBNTPM

No TPM for WINSVR

Either PYBTPM14 or PYBNTPM is required

in ordering Windows Server 2022 OEM

max. 1x per system

When Windows Server 2022 is used as a host OS, PYBTPM14, PY-TPM14, PYBTPM20 or PY-TPM20 is

required. This requirement, however, can be waived if the end customer expresses their desire to

configure the server system without a TPM. In that case, No TPM for WINSVR can be selected.

When Windows Server 2022 is used as a guest OS, TPMs are not necessary.

OS support matrix:

PYBTPM14PYBTPM20

Operating system for host OSPY-TPM14PY-TPM20

Windows Server 2022requiredrequired

Windows Server 2019supportedsupported

Windows Server 2016supported-

Red Hat Enterprise Linux 8supportedsupported

Red Hat Enterprise Linux 7supportedsupported

SUSE Linux Enterprise Server 15--

VMware ESXi 7.0supportedsupported

VMware ESXi 6.7supported-

PYBTPM14/PY-TPM14 are currently available when will be EOL in CQ2'24

PYBTPM20/PY-TPM20 will be an alternative in CQ1'24

because new TPM supports mandatory to fit to new Windows requirement

New TPM are backward compatible with former TPMs.

PY-FOP17

4U Rack Front Bezel

Front Bezel on front Base

max. 1x per system

Your server is ready

cnfgTX2550M7-20231117_hersPage 40 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

Chapter 20 - Thermal Rule

Basic Model(PYT2557T3N / PYT2557T2N) ATD40 and ATD45 can't be supported.

Basic model

CPUMemoryDrive bayOption cardAmbient

4x3.5"8x3.5"8x2.5"LP PCIe / Nvidia T400FH PCIe / GPGPU on PCI RiserTemp.

No limitation

No limitationNo limitationLevel1-6 / Nvidia T400Not support

35C

Basic model for PCIe Level7

CPUMemoryDrive bayOption cardAmbient

4x3.5"8x3.5"8x2.5"LP PCIe / Nvidia T400FH PCIe / GPGPU on PCI RiserTemp.

CPU A

16GB - 64GB DDR5

on board SATA or RAID

CPU B

controller on slot1.

Level1-7 / Nvidia T400Not support

30C

CPU C

CPU D

Not supportNot support

* Need to select Configuration Thermal Design 30℃(PYBETA1)

Standard Model(PYT2557TAN/PYT2557TBN/PYT2557TCN/PYT2557R3N/PYT2557R2N/PYT2557RAN)

Standard model for ATD45

CPUMemoryDrive bayOption cardAmbient

LP PCIe / Nvidia T400FH PCIe / GPGPU on PCI RiserTemp.

No limitation

No limitationNo limitationLevel1-4 / Nvidia T400Not support

45C

* SSD support only. HDD can't be supported. LTO can't be supported.

Standard model for ATD40

CPUMemoryDrive bayOption cardAmbient

LP PCIe / Nvidia T400FH PCIe / GPGPU on PCI RiserTemp.

No limitation

No limitationNo limitationLevel1-5 / Nvidia T400Not support

40C

* SSD support only. HDD can't be supported. LTO can't be supported.

Standard model

CPUMemoryDrive bayOption cardAmbient

LP PCIe / Nvidia T400GPGPU on PCI Riser / FH PCIeTemp.

No limitation

No limitationNo limitationLevel1-6 / Nvidia T400Not support

35C

Standard model for FH PCIe/GPGPU on PCI Riser

CPUMemoryDrive bayOption cardAmbient

LP PCIe / Nvidia T400GPGPU on PCI Riser / FH PCIeTemp.

No limitation No limitation

No limitation

Level1-6 / Nvidia T400

GPGPU Group A / Level1-6

SSD only

GPGPU Group B / Level1-6

30C

* Need to select Configuration Thermal Design 30℃(PYBETA1)

Standard model for PCIe Level7

CPUMemoryDrive bayOption cardAmbient

8x3.5"12x3.5"8x2.5"LP PCIe / Nvidia T400FH PCIe / GPGPU on PCI RiserTemp.

CPU A

16GB - 64GB DDR5

on board SATA or RAID

CPU B

controller on slot1.

Level1-7 / Nvidia T400Not support

30C

CPU C

CPU D

Not supportNot support

* Need to select Configuration Thermal Design 30℃(PYBETA1)

cnfgTX2550M7-20231117_ermalPage 41 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

Option card: PCIe Level for Thermal condition

Card

RAID/SASPDUAL CP100

PDUAL CP300

PSAS CP600e FH / LP

PSAS CP600i LP

PSAS CP600i LP for LTO

PRAID CP600i LP

PRAID EP640i LP

PRAID EP680i LP / NVMe FH / LP

PRAID EP680e RAID Contr. FH/LP

PSAS CP2100-8i LP

PSAS CP2200-16i LP / NVMe FH / LP

PSAS CP 2200-16i LP for LTO

PRAID EP3252-8i LP

PRAID EP3254-8i LP

PRAID EP3258-16i LP / NVMe FH / LP

PRAID EP740i LP / NVMe FH / LP

PFC EP LPe31000 1x 16Gb FH / LP

PFC EP LPe31002 2x 16Gb FH / LP

PFC EP LPe35000 1X 32GFC PCIe v4 / LP

PFC EP LPe35002 2X 32GFC PCIe v4 / LP

PFC EP LPe36000 1X 32GFC PCIe v4 / LP

PFC EP LPe36002 2X 32GFC PCIe v4 / LP

PFC EP QLE2690 1x 16Gb FH / LP

PFC EP QLE2692 2x 16Gb FH / LP

PFC EP QLE2770 1X 32GFC PCIe v4 / LP

PFC EP QLE2772 2X 32GFC PCIe v4 / LP

PFC EP QLE2870 1X 32GFC PCIe v4 / LP

PFC EP QLE2872 2X 32GFC PCIe v4 / LP

PLAN CP 4x1Gbit Cu Intel I350-T4 LP

PLAN EP E810-CQDA2 2X 100G QSFP28 LP

PLAN EP E810-XXVDA2 2X 25G SFP28 FH / LP

PLAN EP E810-XXVDA4 4X 25G SFP28 LP

PLAN EP MCX6-DX 100Gb 2p QSFP28 LP

PLAN EP X710-DA2 2x10Gb SFP+ FH / LP

PLAN EP X710-DA4 4x10Gb SFP+ FH / LP

PLAN EP X710-T2L 2X 10GBASE-T FH / LP

PLAN EP X710-T4L 4X 10GBASE-T FH / LP

PLAN CP BCM5719-4P 4X 1000BASE-T PCIe FH / LP

PLAN EP P210P 2x10Gb SFP FH / LP

PLAN EP P210TP 2X 10GBASE-T PCIe FH / LP

PLAN EP MCX6-LX 25Gb 2p SFP28 PCIe FH / LP

PLAN EP P225P 25Gb 2p SFP28 PCIe FH / LP

PLAN EP P2100G 100Gb 2p QSFP56 PCIe LP

Product Number

PYBVG4A8

PYBVG4L1

PYBVG4A4

PYBVG4A5

PYBVG4A1

PYBVG4L2

PYBGP4A10

PYBVG4A7

PYBGP4H11

PYBVG4A2

PYBVG4L3

Product Number

FH

PYBDMCP24

PYBDMCP35

PYBSC4FAE

- / PYBSR4C62

PYBSR4C6E

- / PYBSC4MA2

FC

LAN

- / PYBSR4MA4

(TBD)

S26361-F5596-E1

S26361-F5596-E2

PYBFC421

PYBFC422

PYBFC441

PYBFC442

S26361-F5580-E1

S26361-F5580-E2

PYBFC411

PYBFC412

PYBFC431

PYBFC432

-

PYBLA432

PYBLA402

PYBLA404

PYBLA412

S26361-F3640-E2

S26361-F3640-E4

PYBLA342

PYBLA344

PYBLA284

PYBLA3J2

PYBLA3K2

PYBLA4024

PYBLA3H2

PYBLA442

LP

PYBDMCP24L

PYBDMCP35L

PYBSC4FAEL

PYBSC4FAL

PYBSC4FA2L

PYBSR4FAL

PYBSR4C63L

PYBSR4C6L / PYBSR4C62L

PYBSR4C6EL

PYBSC3MA2L

PYBSC4MA1L / PYBSC4MA2L

PYBSC4MA3L

PYBSR4MA1L

PYBSR4MA2L

PYBSR4MA3L / PYBSR4MA4L

(TBD)

S26361-F5596-E201

S26361-F5596-E202

PYBFC421L

PYBFC422L

PYBFC441L

PYBFC442L

S26361-F5580-E201

S26361-F5580-E202

PYBFC411L

PYBFC412L

PYBFC431L

PYBFC432L

S26361-F4610-E204

PYBLA432L

PYBLA402L

PYBLA404L

PYBLA412L

S26361-F3640-E202

S26361-F3640-E204

PYBLA342L

PYBLA344L

PYBLA284L

PYBLA3J2L

PYBLA3K2L

PYBLA402L4

PYBLA3H2L

PYBLA442L

PCIe Level

Level4

Level5

Level3

Level3

Level3

Level3

Level3

Level3

Level3

Level3

Level4

Level4

Level4

Level4

Level4

Level4

Level3

Level3

Level4

Level4

Level4

Level4

Level3

Level3

Level4

Level4

Level4

Level4

Level1

Level7

Level5

Level7

Level7

Level1

Level3

Level2

Level3

Level1

Level3

Level5

Level5

Level3

Level5

Option card: GPGPU Group

GroupCard

NVIDIA A2

NVIDIA L4

NVIDIA A16

NVIDIA A30

Group A

NVIDIA A40

NVIDIA L40

NVIDIA A100 80GB

NVIDIA RTX A4500

NVIDIA H100

Group B

NVIDIA RTX A6000

NVIDIA RTX 6000

S

cnfgTX2550M7-20231117_ermalPage 42 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

Date of changeConfigurator revisionFolder / order code / descriptionWhat has been changed / commentName

17.11.2023

13.11.2023

26.10.2023

25.10.2023

24.10.2023

19.10.2023

18.10.2023

16.10.2023

13.10.2023

13.10.2023

13.10.2023

04.10.2023

03.10.2023

03.10.2023

22.09.2023

20.09.2023

1.51

1.50

1.49

1.48

1.47

1.46

1.45

1.44

1.43

1.43

1,42

1.41

1.40

1.39

1,38

1,37

LAN, FC_IB

19.09.2023

14.09.2023

12.09.2023

08.09.2023

04.09.2023

30.08.2023

28.08.2023

28.08.2023

31.07.2023

31.07.2023

28.07.2023

20.07.2023

1.36

1.35

1.34

1,33

1,32

1.31

1.30

1.29

1.28

1.27

1.26

1.25

19.07.2023

14.07.2023

12.07.2023

11.07.2023

04.07.2023

04.07.2023

30.06.2023

29.06.2023

22.06.2023

15.06.2023

13.06.2023

07.06.2023

1.24

1.23

1.22

1.21

1.20

1.19

1.18

1.17

1.16

1.15

1.14

1.13

06.06.2023

05.06.2023

02.06.2023

02.06.2023

02.06.2023

02.06.2023

31.05.2023

30.05.2023

23.05.2023

22.05.2023

16.05.2023

15.05.2023

26.04.2023

1.12

1.11

1.10

1.09

1.08

1.07

1.06

1.05

1.04

1.03

1.02

1.01

1.0

QLE287x released.

Change schedule info of MCX6-LX and Broadcom 25/100G cards

Other (iRMC)Add "iRMC standard/legacy Option" PYBSSS3 in others sheet.

RAMRmoved DDR5 5600 memory

HDD_SSDupdated the description about max qty for M.2 SATA/PCIe drives.

RAMAdded DDR5 Registered DIMM 5600MHz

HDD_SSDreleased SED HDD/SSD

RAIDupdated Note for Intel VROC (SATA RAID)

GFX_FPGAAdd L40S/RTX 4000

HDD_SSDupdated availability schedule

RAIDreleased Intel VROC (VMD NVMe RAID)

HDD_SSDupdated the EOL informaiton for PCIe-SSD

LANAdd I350-T2 PCIe

ODD, othersAdd new order code for half height ODDs, and current order code will be EOL

Add new TPM

RAIDreleased Intel VROC (SATA RAID)

HDD_SSDadded the limitation about VROC for PCIe-SSD

HDD_SSD, HDD_SSD (short depth)updated availability schedule

added the following drives as new products

-Samsung PM1653 as SSD SAS 2.5"

-Samsung PM897a/PM893a as SSD SATA 2.5"/3.5"

Energy Staradded E-Star Fam1/Fam2 Certification for ENERGY STAR V4.0

RAID, backupupdated availability schedule

ThermalModified thermal rule for FH PCIe/GPGPU on PCI Riser for clear information

added the EOL status for HDD SAS 15K and HDD 2.5" BC-SATA/SAS

HDD_SSD

updated availability schedules for SSD SAS "PM7"

HDD_SSD

HD_SSD, Thermaladded PDUAL CP300

PYBDMCP35, PYBDMCP35L, PY-DMCP35

PCI_riser_cardchanged chapter name to ’PCI_riser_card’ and updated description

ThermalAdding MCX6-LX 25G and P(N)225P, P(N)2100G info to Thermal sheet

HD_SSDrevised the order codes for Kioxia CM7 15.36TB

HD_SSDadded the PCIe-SSD "kioxia CM7 series"

base, PCI_RiserSeparating PCI_Riser section to Chapter 14 from Chapter 1 - base unit

LANAdding Broadcom 25G/100G cards.

Adding NVIDIA 25G cards.

Deleting E810-CQDA2 and MCX6-DX 100G FH cards because thermal level is 7

and cannot be used it as FH.

GFX_FPGADelete A30X/A100X.

FC_IBDelete the restriction of QLE277x because System T50 includes these cards and

no issues.

ThermalRevice the limitation for RTX A6000

RAIDupdated availability schedule

GFX_FPGAAdded the RTX 6000

ThermalAdded the limitation for RTX A6000

othersNo TPM for WINSVR added

ThermalModified for clear information

BaseRemoved '1x USB 3.1 Gen1(type A)' from Interfaces internal

HD_cageRemoved availability schedule for PYBBA28ST

GFX_FPGAL4/L40

updated availability schedule

RAIDadded Intel VROC (SATA RAID)

added Intel VROC Upgrade Key

PYBRLVR02, PY-RLVR02

updated availability schedule

GFX_FPGAUpdated NVLink and L4 and L40, H100.

HD_cageRemoved 'except for PCIeSSDs'

HD_SSDupdated availability schedule

ThermalAdded H100 limitation.

LANChange max number of Broadcom 10G LAN P210P, P210TP LP cards from 6 to

4.

This is due to SA:233766419. Slot#3 and slot#10 cannot be used.

HD_cageRemove the limitation for the number of disks from

PYBBA24PJ/PYBBA24PK/PYBCBE024/PYBCBE025

HD_cageAdded PY-BA34SA/PY-BA34SB/PY-BA28SQ/PY-BA28SR/PY-BA28SS/PY-

BA28ST/PY-BA24PJ/PY-BA24PK/PY-CBE024/PY-CBE025

HD_cageRemove the limitation for the number of disks from PYBBA28SS

updated availability schedule for PYBBA28ST

ThermalRevice the detail

HD_SSDremoved the BC-SATA 20TB due to release cancel

HD_SSDchanged the max qty from "2" to "1" for M.2 SSD due to not support of VROC

RAID, backupupdated availability schedule

1st release

F. Kanega

H. Ogino

H. Konno

Y. Sugiyama

T. Sudou

a

T. Sudou

T. Sudou

Y. Sugiyama

F. Kanega

H. Konno

T. Sudou

Y. Sugiyama

Y. Sugiyama

T. Sudou

Y. Sugiyama

Y. Sugiyama

T. Sudou

F. Kanega

Y. Sugiyama

Y. Sugiyama

F. Kanega

S. Fujita

T. Sudou

a

S. Fujita

K. Nishihara

S. Fujita

S. Fujita

T. Sudou

a

T. Sudou

M. Takaoka/T. Sasaki

S. Fujita

T. Sudou

S. Fujita

F. Kanega

S. Fujita

S. Fujita

S. Fujita

S. Fujita

Y. Sugiyama

Y. Sugiyama

T. Sudou

S. Fujita

cnfgTX2550M7-20231117_ange_historyPage 43 of 43

2024年9月26日发(作者:梁丘芸芸)

PRIMERGY TX2550 M7

Tower or 4U Rack server

ChapterFolder

Cover

Description

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

Base

CPU

RAM

GFX

HD_cage

RAID

ODD

Backup

HD_SSD

LAN

FC_IB

PCI_riser_card

PSU

USB_devices

Energy Star

ErP Lot9

others

Thermal

Content

List of content, Instructions for usage of this configurator,

abbreviations

System Description for easier understanding

Describes base units of TX2550 M7

Describes rack mount kits and services

Order codes, information Xeon processors

DDR5 System memory (RAM) and memory modes

Graphics-, Grid-cards, GPU and Xeon Co processors

HDD cage kits

SAS / RAID Controller and components

Optical disk drives (DVD, DVD-rw, Blu ray)

LTO drives & RDX drive

Storage drives - PCIe SSD - SAS/SATA SSD & HDD

LAN Components

Fibre Channel Controller

Infiniband Controller

PCI Riser

Power supply units, power cables, country specifics

Keyboards, Mice, USB devices

Energy Star limitation

Erp Lot9 limitation

System Management, ATD, RS232 port, TPM module

Thermal Rule

Instructions

This document contains basic product and configuration information that supports you in more complicated configurations.

In any case we recommend to use the WebArchitect to make sure, that you configure a valid system.

This System configurator is divided into several chapters. They are identical to the current price list and WebArchitect.

Please follow this document step by step from the top to the bottom

Chapter xx - description of chapter

Text fields with grey color offer extra information for related topics (e.g prerequesites, technical back

ground, configuration rules, limitations, …

S26361-F4610-E2

S26361-F4610-L3

PLAN 2x1Gb Ethern. Controller

i350-T2 chip (based on Intel Powerville) offers

2x1Gb RJ45 connectors

PCIe Gen2 x4 full height card

max. 6x per system

<-- order code E-part (bold) --

<-- order code L-part (bold)

<-- "name" of this part

<--description of this part, in same cases as well description of content

<--requires a free PCIe slot --> means total amount of PCIe slots reduced

<--indicates how often this part can be configured in the related Server

New order code

PYBVAP05

PY-VAP05

Front VGA connector (15-pin)

Front VGA connector (15-pin) including cable

and front connector

Not for 12x3.5", 24x2.5", 64xEDSFF base unit.

max. 1x per system

<-- "PYB" order code (bold) for BTO(Built to Order) part

<-- "PY-" order code (bold) for Loose delivery part

<-- "name" of this part

<--description of this part, in same cases as well description of content

<-- Limitation for this part

<--indicates how many this part can be configured in the related Server

For further information see:

Link to datasheet:

/dmsp/Publications/public/

/products/standard_servers/

(internet)

/com/order-supply/configurators/primergy_config/Pages/

(extranet)

Fujitsu is providing the content of this document with very high accuracy. In case you identify a mistake, we would kindly encourage you to inform us.

We kindly ask for understanding, that errors still may occur and that Fujitsu may change this document without notice

Abbreviations

SAS

SATA

HDD

SSD

SFF

LFF

CPU

RAID

Spaces

vSAN

storage tiering

hot data

cold data

ODD

OS

E-Part

L-Part

Drives, RAID

Drives, RAID

Drives

Drives

Drives

Drives

Processor

Drives, RAID

OS

OS

RAID

Drives

Drives

Drives

operating system

"Einbau-Part"

"Lose Lieferung-Part"

Serial attached SCSI Device (HDD, SSD, LTO drives); SAS2.0 = 6GBit/s; SAS3.0 = 12GBit/s

Serial ATA (HDD, SSD) current SATA speed = 6GBit/s

Hard disk drive (Non volatile storage device), 2.5" (SFF) or 3.5" (LFF)

Solid state disk (Non volatile storage device), 2.5" (SFF)

small form factor (=2.5")

large form factor (=3.5")

central processing unit ("processor")

RAID 0 = max speed, RAID 1 = mirroring, RAID 5 = 1 out of x drives is spare

Microsoft spaces, optimized in Win2012 R2 offers software RAID and storage tiering

offers optimized storage allocation (fast area for "hot data"; slower area for "cold data")

Data which are currently being processed

Data which are currently not processed (only stored)

optical disk drive (i.e. DVD-player, DVD-burner, Blu ray player, blu ray burner)

OS=operating system - required for running, organize and administrating the server

"e.g. S26361-F1234-E240" ordercode with "E" means it is either integrated into to Server (CPU, Mem, ..) or integrated in the

shipping box /Keyboard, Mouse, ..)

"e.g. S26361-F1234-L240" ordercode with "L" means, the part will be shipped with extra package, may be as well with extra

shipment

PRIMERGY TX2550 M7

System configurator and

order information guide

PCI Riser left (CPU2)

PCI Riser right (CPU1)

PRIMERGY TX2550 M7 rear view

cnfgTX2550M7-20231117_scriptionPage 4 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

PRIMERGY TX2550 M7 front view with drives

The front views shown below represent all possible drive options; they do not represent the base units.

For information on base units and HD drive cage for each drive option, please see chapter “base” and "HD_cage"

3.5-inch hot plug SAS/SATA

4x HDDs/SSDs8x HDDs/SSDs12x HDDs/SSDs

2.5-inch hot plug SAS/SATA/NVMe

8x HDDs/SSDs16x HDDs/SSDs16x HDDs/SSDs + 8xHDDs/SSDs/NVMes

24x HDDs/SSDs24x HDDs/SSDs + 8xHDDs/SSDs/NVMes

recommended components for TX2550 M7

Independant Mode installation

iRMC S6 advanced pack

Modular PSU 900W Titanium hot plug

#

1x

1x

2x

cnfgTX2550M7-20231117_scriptionPage 5 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

Chapter 1 - base unit

Start

Power supply units & cooling:

PRIMERGY TX2550 M7 offers bays for 2x (1x optional hot plug redundant) power supply units of 500W, 900W, 1600W, 2400W with up to 96% efficiency. 2200W with up to 94%

efficiency. Rack options ex factory or via retrofit upgrade with rack conversion kit.

Server Management:

iRMC S6 (integrated Remote Management Controller) on-board with dedicated Service LAN-port and integrated graphics controller. With onboard indicators and controls to easily

highlight failed components via LEDs displayed during service even without mains connection by simply pressing

the "indicate CSS" button. Optional ServerView Suite software incl. ServerView Installation Manager, Server View Remote Management and tools.

Platform:

Fujitsu Systemboard D3985-A made in Taiwan based on Chipset Intel® C741, up to two Xeon (Sapphire Rapids) series CPUs, four Intel® UltraPath

Interconnect (Intel® UPI) point-to-point links and onboard RAID 0/1 6Gbit/s available for up to 8x SATA drives.

16GB SD card as default

Slots: 6x PCIe slots are on board, with optional riser card up to 10x PCIe slots are available:

> 6x PCIe slots onboard, low profile, 167mm lengh, supported with first/second CPU:

Slot 1: PCIe-Gen5 x16

Slot 2: PCIe-Gen5 x16 (occupied in configurations with optional riser card)

Slot 3: PCIe-Gen5 x16 (occupied in configurations with optional riser card)

Slot 8: PCIe-Gen5 x16

Slot 9: PCIe-Gen5 x16 (occupied in configurations with optional riser card)

Slot 10: PCIe-Gen5 x16 (occupied in configurations with optional riser card)

> Optional full height riser card on PCIe slot 2/3/9/10 offers 4x additional PCIe slots, full height, 252mm and 1x PCI4/5 , with first/second CPU:

Slot 4/11: PCIe-Gen4/5 x16

Slot 5/12: PCIe-Gen4/5 x16

> Optional full height riser card on PCIe slot 2/3/9/10 offers 8x additional PCIe slots, full height, 252mm and 1x PCI4/5, with first/second CPU:

Slot 4/11: PCIe-Gen4/5 x8

Slot 5/12: PCIe-Gen4/5 x8

Slot 6/13: PCIe-Gen4/5 x8

Slot 7/14: PCIe-Gen4/5 x8

System RAM:

16x slots for DDR5-4800MHz RAM modules available (8x RAM modules per CPU). Memory speed depends on CPU and configuration.

LAN: 2x 1Gb LAN onboard;

Interfaces at rear sideInterfaces at front side

- 1x optional RS-232-C (serial port, 9 pin)- 2x USB 3.1 Gen1 (no USB wakeup)

- 2x LAN Rj45 (additional 2x RJ45 optionally available)

Interfaces internal

- 1x service LAN RJ45 (1 Gbit)

- 1x USB 3.1 Gen1 for backup devices

- 1x VGA (15 pins)

- 2x M.2

- 4x USB 3.1 Gen1

- 1x connector for TPM, 1x microSD card slot

Tower base units;

-Low noise hotplug fans

-up to 6 PCIe slots

Tower base units;

-High performance hotplug fans

-up to 10 PCIe slots

Rack base units;

-High performance hotplug fans

-up to 10 PCIe slots

C

h

o

o

s

e

o

n

e

b

a

s

e

u

n

i

t

PY TX2550 M7 Tower, 4x3.5" basic

PYT2557T3N

Tower server, expandable to 8x3.5";

Not support GPGPU

PY TX2550 M7 Tower, 8x3.5"

PYT2557TAN

Tower server, expandable to 12x3.5";

PY TX2550 M7 Rack, 8x3.5"

PYT2557R3N

Rack server, expandable to 12x3.5";

PY TX2550 M7 Tower, 8x2.5" basic

PYT2557T2N

Tower server, not expandable;

Not support GPGPU

PY TX2550 M7 Tower, 8x2.5"

PYT2557TBN

Tower server, expandable to 24x2.5";

PY TX2550 M7 Rack, 8x2.5"

PYT2557R2N

Rack server, expandable to 24x2.5";

PY TX2550 M7 Tower 4x3.5' basic and PY

TX2550 M7 Tower 8x2.5' basic do not support

Advanced Thermal design(ATD) options!

PY TX2550 M7 Tower, 24x2.5"

PYT2557TCN

Tower server, expandable to 32x2.5";

PY TX2550 M7 Rack, 24x2.5"

PYT2557RAN

Rack server, expandable to 32x2.5";

APRIMECENTER Rack

cnfgTX2550M7-20231117_sePage 6 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

Chapter 2 - Rack architecture

APRIMECENTER Rack

S26361-F2735-E111 PYBRRL6PY-RC18

No Rackmount-KitPY-RRL6

Rack conversion kit

No rackmount. Upgrade later possible

Rack Mount Kit F2-C S7 LV

Contains all necessary parts to convert PRIMERGY TX2550

with L-part

telescopic drop-in rail, full extractical, supports 1-

M7 Tower Server into a Rack server.

max. 1x per system

hand-mounting

Rackmount Kit ex factory

Rack mounting kit has to be ordered seperately.

> 1 pair of vario carrier with variable length & quick

release lever support

> 1 pair of telescopic drop-in rails with Cable

Management Arm (CMA) adapter

1x per system

S26361-F2735-E82

S26361-F2735-L82

2U cable management arm (CMA) for

2U server or higher

for mounting in symmetrical

PRIMECENTER M2/M1 racks

- 1 bracket PC M2/M1 Rack

1x per system

S26361-F1647-E302

Installation ex factory in a PRIMECENTER Rack

The installation service is to be ordered once per installable server/storage

Fujitsu will deliver the PRIMERGY mounted in a Rack System and all wired

subsystem, in order to get the server/storage subsystem mounted into the

connections are tested with PRIMECENTER rack - Systems and components will be

racks. In case of the 46 U PCR S2 this service has to be ordered, to get the

delivered installed in the rack

mounting kits and the cables installed.

max. 1x per System

B

cnfgTX2550M7-20231117_sePage 7 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

Chapter 3 - CPU

B

General Discription

There are 2 processor sockets available. Please configure 1 or 2 Processors.

>> All processors have to be the same type.

>> With one processor iRMC, 3x PCIe low profile slots(Up to 1x PCIe low profile + 4x PCIe full height) and 8x DIMM slots are available

>> With two processors all 16x DIMM slots, 6x PCIe low profile slots are available. Up to 2x PCIe low profile + 8x PCIe full height.

>> To configure 2nd CPU an additional cooler kit is required.

* HT = Hyper Threading

Notice

** Base Unit is not including CPUs. Minimum 1x CPU is required to be configured in one base unit.

** Maximum 2x CPUs are allowed to be configured in one base unit. Only 1 type of CPU can be configured in one base unit.

**CPU: PYBCP65XR, PYBCP65XS and PYBCP65X1 are not allowed to be configured 2x CPUs

CPU Group for

Thermal condition

Xeon Bronze 34xx - Mainline, 1 socket configuration only(BTO)(Loose delivery)

64-bit Intel Xeon processor supporting HT*, DDR5 @ 4000 MT/s

Xeon Bronze 3408U 8C 1.8GHz 125WPYBCP65XR-A

MCC

Xeon Silver 44xx - Mainline, 2 socket scalability(BTO)(Loose delivery)

64-bit Intel Xeon processor supporting HT*, DDR5 @ 4000 MT/s & UPI Bus (2UPI) @ 16 GT/s

Xeon Silver 4410Y 12C 2.0GHz 150W Speed Select TechnologyPYBCP66XGPY-CP66XGA

MCC

Xeon Silver 4416+ 20C 2.0GHz 165WPYBCP66XHPY-CP66XHB

MCC

Xeon Gold 54xx - Mainline/Performance Optimized, 1 socket configuration only(BTO)(Loose delivery)

64-bit Intel Xeon processor supporting HT*, DDR5 @ 4400 MT/s

Xeon Gold 5412U 24C 2.1GHz 185WPYBCP65XS-B

MCC

Xeon Gold 54xx - Mainline/Performance Optimized, 2 socket scalablity(BTO)(Loose delivery)

64-bit Intel Xeon processor supporting HT*, DDR5 @ 4400 MT/s & UPI Bus (3UPI) @ 16 GT/s

Xeon Gold 5415+ 8C 2.9GHz 150WPYBCP65XTPY-CP65XTA

MCC

Xeon Gold 5418Y 24C 2.0GHz 185W Speed Select TechnologyPYBCP65XWPY-CP65XWB

MCC

Xeon Gold 5420+ 28C 2.0GHz 205WPYBCP65XXPY-CP65XXB

MCC

Xeon Gold 64xx - Mainline/Performance Optimized, 1 socket configuration only(BTO)(Loose delivery)

64-bit Intel Xeon processor supporting HT*, DDR5 @ 4800(1DPC) / 4400(2DPC) MT/s

Xeon Gold 6414U 32C 2.0GHz 250WPYBCP65X1-C

XCC

Xeon Gold 64xx - Mainline/Performance Optimized, 2 socket scalability(BTO)(Loose delivery)

64-bit Intel Xeon processor supporting HT*, DDR5 @ 4800(1DPC) / 4400(2DPC) MT/s & UPI Bus (3UPI) @ 16 GT/s

Xeon Gold 6426Y 16C 2.5GHz 185W Speed Select TechnologyPYBCP66X2PY-CP66X2B

MCC

Xeon Gold 6430 32C 2.1GHz 270W (DDR5 @ 4400(1DPC/2DPC)) PYBCP65X2PY-CP65X2D

XCC

Xeon Gold 6434 8C 3.7GHz 195WPYBCP66X4PY-CP66X4B

MCC

Xeon Gold 6438Y+ 32C 2.0GHz 205W Speed Select TechnologyPYBCP66X8PY-CP66X8B

MCC

Xeon Gold 6442Y 24C 2.6GHz 225W Speed Select TechnologyPYBCP66X9PY-CP66X9C

MCC

Xeon Gold 6448Y 32C 2.1GHz 225W Speed Select TechnologyPYBCP66XCPY-CP66XCC

MCC

Xeon Platinum 84xxH - IMDB/Analytics Workload Optimized, 8 socket scalability(BTO)(Loose delivery)

64-bit Intel Xeon processor supporting HT*, DDR5 @ 4800(1DPC) / 4400(2DPC) MT/s & UPI Bus (4UPI) @ 16 GT/s

Xeon Platinum 8444H 16C 2.9GHz 270WPYBCP65X4PY-CP65X4D

XCC

Xeon Platinum 8450H 28C 2.0GHz 250W Speed Select TechnologyPYBCP65X6PY-CP65X6C

XCC

Xeon - Storage & HCI Workload Optimized, 2 socket scalability(BTO)(Loose delivery)

64-bit Intel Xeon processor supporting HT*, DDR5 @ 4800(1DPC) / 4400(2DPC) MT/s & UPI Bus (3UPI) @ 16 GT/s

Xeon Gold 5416S 16C 2.0GHz 150W (DDR5 @ 4400(1DPC/2DPC)) Speed Select TechnoPYBCP65XUPY-CP65XUA

MCC

Xeon Gold 6454S 32C 2.2GHz 270W Speed Select TechnologyPYBCP65X3PY-CP65X3D

XCC

Xeon - Long-Life Use (IOT) Workload Optimized, 2 socket scalability(BTO)(Loose delivery)

64-bit Intel Xeon processor supporting HT*, DDR5 @ 4000 MT/s & UPI Bus (2UPI) @ 16 GT/s

Xeon Silver 4410T 10C 2.7GHz 150W Speed Select TechnologyPYBCP66XFPY-CP66XFA

MCC

Notice

2CPU configuration require to order 2nd CPU cooler kit

CPU Cooler kit(BTO)(Loose delivery)

2nd CPU Cooler kit for Basic model***PYBTKCPC85-

2nd CPU Cooler kit****PYBTKCPC86-

CPU cooler kit for loose delivery CPU for Basic model***-PY-TKCPC85

CPU cooler kit for loose delivery CPU****-PY-TKCPC86

*** For PYT2557T3N/PYT2557T2N

**** For PYT2557TAN/PYT2557TBN/PYT2557TCN/PYT2557R3N/PYT2557R2N/PYT2557RAN

C

cnfgTX2550M7-20231117_UPage 8 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

Chapter 4 - DDR5 System memory

C

Each CPU offers 8 Slots for DDR5 Memory Modules organised in 1 Banks and 8 Channels with 4 Memory Controllers (2 Channels each).

If you need more than 8 Slots you have to configure 2nd CPU.

Depending on the amount of memory configured you can decide between the Normal Memory RAS mode or the Mirroring Memory RAS Mode.

There are different kinds of DDR5 Memory Modules available: RDIMM x4, RDIMM x8, RDIMM 3DS x4.

Mix of different memories is not allowed.

Supported memory capacities per CPU:

Up to 2TB using DDR5 RDIMM (8x 256GB DDR5 RDIMM 3DS)

Supported memory capacities per System (with 2CPU configuration):

Up to 4TB using DDR5 RDIMM (16x 256GB DDR5 RDIMM 3DS)

The memory speed depends on configuration restricted by the CPU SKU (max. 4800 MT/s).

DDR5 memory is operated at 1.1V

Memory Mode ; One of followig memory modes must be selected.

Independent ModeRequires 1, 2, 4, 6 or 8 Memory Modules per CPU1x per CPUPYBMMD2

Independent Mode required to be the best performance.

ADDDC Sparing is available in case system configured by DDR5 xRx4 DIMM only.

Mirroring ModeRequires 8 Memory Modules per CPU1x per CPUPYBMMC4

BIOS preconfiguration for Mirroring mode. 8x identical memory modules are always equipped on same bank across all channels to use the mirrored channel mode. Half of the

modules contain active data, the remaining modules contain mirrored data.

min/max 1x per CPU; max 2x for System

DDR5 DIMM only configuration section

Min 1x DIMM per CPU is required. Any Mix of RDIMMx8, RDIMMx4, RDIMM 3DS is not allowed.

DDR5 Registered DIMM 4800MHz 1R/2R x8

16GB (1x16GB) 1Rx8 DDR5-4800 R ECC

max 8x per CPUPYBME16SLPY-ME16SL

32GB (1x32GB) 2Rx8 DDR5-4800 R ECC

max 8x per CPUPYBME32SLPY-ME32SL

max 8x per CPU; max 16x for System

DDR5 Registered DIMM 4800MHz 1R/2R x4

32GB (1x32GB) 1Rx4 DDR5-4800 R ECC

max 8x per CPUPYBME32SL2PY-ME32SL2

64GB (1x64GB) 2Rx4 DDR5-4800 R ECC

max 8x per CPUPYBME64SLPY-ME64SL

max 8x per CPU; max 16x for System

DDR5 Registered DIMM 4800MHz 3DS 4R/8R x4

128GB (1x128GB) 4Rx4 DDR5-4800 R 3DS ECC

max 8x per CPUPYBME12SLPY-ME12SL

256GB (1x256GB) 8Rx4 DDR5-4800 R 3DS ECC

max 8x per CPUPYBME25SLPY-ME25SL

max 8x per CPU; max 16x for System

D

cnfgTX2550M7-20231117_MPage 9 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

Detailed information

RAS feature

ECC

SDDC

ADDDC Sparing

Mirroring channel

Memory Mode

Normal Mode/Mirroring Mode

Normal Mode/Mirroring Mode

Normal Mode

Mirroring Mode

RDIMM

x8

yes

no

no

yes

RDIMM

LRDIMM

x4

yes

yes

yes

yes

BIOS setting

always enabled.

always enabled in case x4 DIMM conifugred.

disabled as default.

enabled in case Mirroring Mode ordered.

Configuration

Min. Memory

Max. Memory per CPU

Max. Memory per System

DIMM

1 Module / CPU

8 Module / CPU

16 Modules / CPU

32 Modules / System

CPU

with one CPU

with one CPU

with two CPU

with two CPU

Normal Mode

16GB: 16GB x1

-

2TB: 256GB x8

4TB: 256GB x16

Available Capacity

Mirroring Mode

-

64GB: 16GBx8x50%

1TB: 256GBx8x50%

2TB: 256GBx16x50%

The memory sockets on the Systemboards are color coded

C

h

a

n

n

e

l

G

C

h

a

n

n

e

l

A

C

h

a

n

n

e

l

B

C

h

a

n

n

e

l

C

C

h

a

n

n

e

l

D

Bank Iblack sockets

iMC0iMC1

CPU

iMC2iMC3

Normal Mode population DDR5 DIMM only

Normal Mode requires 1x, 2x, 4x, 6x or 8x DIMM configuration per CPU.

for 2x or more than 2x DIMM configuration,

Between Chanel A-E/C-G/B-F/D-H, balanced configuration is required. same bank of each chanel need to be populatd.

Between Chanel A-C-E-G/B-D-F-H, each chanel capacity need to be same if DIMM poputated in each Chanel.

1 DIMMs for 1CPU1 DIMMs for 1CPU

C

h

a

n

n

e

l

G

C

h

a

n

n

e

l

H

C

h

a

n

n

e

l

E

C

h

a

n

n

e

l

F

C

h

a

n

n

e

l

G

C

h

a

n

n

e

l

A

C

h

a

n

n

e

l

B

C

h

a

n

n

e

l

C

C

h

a

n

n

e

l

D

C

h

a

n

n

e

l

H

C

h

a

n

n

e

l

A

C

h

a

n

n

e

l

B

C

h

a

n

n

e

l

C

C

h

a

n

n

e

l

D

Data

iMC0iMC1

CPU

1 DIMMs for 1CPU1 DIMMs for 1CPU

iMC2iMC3iMC0iMC1

CPU

Data

iMC2iMC3

C

h

a

n

n

e

l

G

C

h

a

n

n

e

l

G

C

h

a

n

n

e

l

A

C

h

a

n

n

e

l

B

C

h

a

n

n

e

l

C

C

h

a

n

n

e

l

D

C

h

a

n

n

e

l

H

C

h

a

n

n

e

l

A

C

h

a

n

n

e

l

B

C

h

a

n

n

e

l

C

C

h

a

n

n

e

l

D

Data

iMC0iMC1

CPU

iMC2iMC3iMC0iMC1

CPU

iMC2

Data

iMC3

cnfgTX2550M7-20231117_M

C

h

a

n

n

e

l

H

C

h

a

n

n

e

l

E

C

h

a

n

n

e

l

E

C

h

a

n

n

e

l

F

C

h

a

n

n

e

l

F

C

h

a

n

n

e

l

H

C

h

a

n

n

e

l

E

C

h

a

n

n

e

l

E

C

h

a

n

n

e

l

F

C

h

a

n

n

e

l

F

Page 10 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

2 DIMMs for 1CPU

2x identical memory modules need to be populated.

2 DIMMs for 1CPU

2x identical memory modules need to be populated.

C

h

a

n

n

e

l

G

C

h

a

n

n

e

l

G

C

h

a

n

n

e

l

A

C

h

a

n

n

e

l

B

C

h

a

n

n

e

l

C

C

h

a

n

n

e

l

D

C

h

a

n

n

e

l

H

C

h

a

n

n

e

l

A

C

h

a

n

n

e

l

B

C

h

a

n

n

e

l

C

C

h

a

n

n

e

l

D

Data

iMC0iMC1

CPU

4 DIMMs for 1CPU

4x identical memory modules need to be populated.

iMC2

Data

iMC3iMC0

Data

iMC1

CPU

Data

iMC2iMC3

6 DIMMs for 1CPU

6x identical memory modules need to be populated.

C

h

a

n

n

e

l

G

C

h

a

n

n

e

l

G

C

h

a

n

n

e

l

A

C

h

a

n

n

e

l

B

C

h

a

n

n

e

l

C

C

h

a

n

n

e

l

D

C

h

a

n

n

e

l

H

C

h

a

n

n

e

l

A

C

h

a

n

n

e

l

B

C

h

a

n

n

e

l

C

C

h

a

n

n

e

l

D

Data

iMC0

Data

iMC1

CPU

Data

iMC2

Data

iMC3

Data

iMC0

Data

iMC1

DataData

iMC2

CPU

DataData

iMC3

6 DIMMs for 1CPU

6x identical memory modules need to be populated.

6 DIMMs for 1CPU

6x identical memory modules need to be populated.

C

h

a

n

n

e

l

G

C

h

a

n

n

e

l

G

C

h

a

n

n

e

l

A

C

h

a

n

n

e

l

B

C

h

a

n

n

e

l

C

C

h

a

n

n

e

l

D

C

h

a

n

n

e

l

H

C

h

a

n

n

e

l

A

C

h

a

n

n

e

l

B

C

h

a

n

n

e

l

C

C

h

a

n

n

e

l

D

Data

iMC0

DataData

iMC1

CPU

Data

iMC2

Data

iMC3

Data

iMC0

DataData

iMC1

DataData

iMC2

CPU

Data

iMC3

Data

6 DIMMs for 1CPU

6x identical memory modules need to be populated.

8 DIMMs for 1CPU

8x identical memory modules need to be populated.

C

h

a

n

n

e

l

G

C

h

a

n

n

e

l

G

C

h

a

n

n

e

l

A

C

h

a

n

n

e

l

B

C

h

a

n

n

e

l

C

C

h

a

n

n

e

l

D

C

h

a

n

n

e

l

H

C

h

a

n

n

e

l

A

C

h

a

n

n

e

l

B

C

h

a

n

n

e

l

C

C

h

a

n

n

e

l

D

Data

iMC0

Data

iMC1

Data

iMC2

CPU

DataData

iMC3

DataData

iMC0

DataData

iMC1

DataData

iMC2

CPU

DataData

iMC3

Data

Mirroring Mode population DDR5 DIMM only

Mirroring Mode requires 8x or 16x DIMM configuration per CPU.

in addition to Normal Mode Memory population rules,

Between Chanel A-B/C-D/E-F/G-H, identical DIMM need to be populated in same bank.

8 DIMMs for 1CPU

C

h

a

n

n

e

l

G

C

h

a

n

n

e

l

A

C

h

a

n

n

e

l

B

C

h

a

n

n

e

l

C

C

h

a

n

n

e

l

D

DataMirror

iMC0

DataMirror

iMC1

CPU

DataMirror

iMC2

DataMirror

iMC3

cnfgTX2550M7-20231117_

C

h

a

n

n

e

l

H

C

h

a

n

n

e

l

E

C

h

a

n

n

e

l

F

RAM

C

h

a

n

n

e

l

H

C

h

a

n

n

e

l

E

C

h

a

n

n

e

l

E

C

h

a

n

n

e

l

F

C

h

a

n

n

e

l

F

C

h

a

n

n

e

l

H

C

h

a

n

n

e

l

E

C

h

a

n

n

e

l

E

C

h

a

n

n

e

l

F

C

h

a

n

n

e

l

F

C

h

a

n

n

e

l

H

C

h

a

n

n

e

l

E

C

h

a

n

n

e

l

E

C

h

a

n

n

e

l

F

C

h

a

n

n

e

l

F

C

h

a

n

n

e

l

H

C

h

a

n

n

e

l

E

C

h

a

n

n

e

l

E

C

h

a

n

n

e

l

F

C

h

a

n

n

e

l

F

Page 11 of 43

The different GPU mixed configuration

does NOT support.

The different GPU mixed configuration

does NOT support.

These combination between RTX series and these Adapters(S26361-F4066-E12/L12,

S26361-F4066-E13/L13) are ristriction. It will be avaiable in 09.2023

FPGA Card T.B.D. to be available from GA

PRIMERGY TX2550 M7

System configurator and

order information guide

Chapter 6 - HD drive cage

F

HD drive cage is a metal box providing bays for 3.5" HDDs or 2.5" HDDs/SSDs/PCIe-SSDs. Choose out of the

following HD cage upgrade kits, depending on pre-selected TX2550 M7 base unit and the targeted configuration. Each upgrade kit contains all relevant

parts such as metal cage, backplane, cables and mounting material.

Upgrade kits for the upper drive area require the completion of the mid drive area.

Up to 3x 1.6x5.25" bays are available in the upper drive area for an ODD and/or backup drive configurations; in the 12x3.5" configuration, a 9.5mm bay is

available for a slim ODD. Refer to sections "ODD" and "backup" for details.

Upgrade kits are available either ex-factory (E-codes) or as loose delivery party (L-codes).

RAID configurations are recommendations; refer to section "RAID" for available options.

Preferred slots for controller assignementGeneral drive numbering scheme

Rear side view (incl. riser card option; refer to sheet "Description" for details)

TX2550 M7 front views of expandable base units and corresponding HD drive cage options:

If you change channel for HBA- or RAID-Controller as loose delivery, SAS cable need to be changed.

Option BPY-CBS085SAS cable for CP2100-8i

Option CPY-CBS086SAS cable for CP6xx/EP6xx/EP32xx

Base Unit

PY TX2550 M7 Tower, 4x3.5" basic

PYT2557T3N

RAID configuration1x HBA- or RAID-Controller. Refer to section "RAID" for options. Onboard SATA (max. 8x disks)

ODD / Backup3x 1.6x5.25" bays are available for an optical and/or backup drives in the upper drive area.

Upgrade kit for 4x3.5" HDD

PYBBA34SAPY-BA34SA

Upgrade kit for 4x3.5" HDD, mounted in the mid

drive area

Base Unit

PY TX2550 M7 Tower, 8x3.5"PY TX2550 M7 Rack, 8x3.5"

PYT2557TANPYT2557R3N

RAID configuration1x HBA- or RAID-Controller. Refer to section "RAID" for options. onboard SATA(Max. qty. for Disk is eight.)

if no upper drive area is installed, the below can be selected.

ODD / Backup3x 1.6x5.25" bays are available for an optical and/or backup drives in the upper drive area.

HD cage upgrades for upper drive area

Upgrade kit for 4x3.5" HDD

PYBBA34SBPY-BA34SB

Upgrade kit for 4x3.5" HDD, mounted in the

upper drive area,

incl. 40x SAS Expander

1x 9.5mm bay is available for a slim optical drive

in the upper drive area.

Note! This option requires 1x PRAID/HBA per

Base unit

RAID configuration1x HBA- or RAID-Controller. Refer to section "RAID" for options.

ODD / Backup1x 9.5mm bay is available for a slim optical drive in the upper drive area.

Base Unit

PY TX2550 M7 Tower, 8x2.5" basic

PYT2557T2N

RAID configuration1x HBA- or RAID-Controller. Refer to section "RAID" for options. onboard SATA(Max. qty. for Disk is eight.)

ODD / Backup3x 1.6x5.25" bays are available for an optical and/or backup drives in the upper drive area.

cnfgTX2550M7-20231117__cagePage 14 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

Base unit

PY TX2550 M7 Tower, 8x2.5"PY TX2550 M7 Rack, 8x2.5"

PYT2557TBNPYT2557R2N

RAID configuration1x HBA- or RAID-Controller. Refer to section "RAID" for options. onboard SATA(Max. qty. for Disk is eight.)

if no upper drive area is installed, the below can be selected.

ODD / Backup3x 1.6x5.25" bays are available for an optical and/or backup drives in the upper drive area.

HD cage upgrades

Upgrade kit for 8x2.5" HDDUpgrade kit for 8x2.5" HDD

PYBBA28SQPY-BA28SQPYBBA28SRPY-BA28SR

Upgrade kit for 8x2.5" HDD, mounted in the mid Upgrade kit for 8x2.5" HDD, mounted in the mid

drive area,drive area,

for connect 16port RAID option

incl. 40x SAS Expander

Note! This option requires 1x 16-channel

PRAID/HBA

Note! This option requires 1x PRAID/HBA

Upgrade kit for the upper drive area

Please refer to “Upgrade kit for the upper drive area with PYT2557TBN/ PYT2557R2N/ PYT2557TCN/ PYT2557RAN

Base unit

PY TX2550 M7 Tower, 24x2.5"PY TX2550 M7 Rack, 24x2.5"

PYT2557TCNPYT2557RAN

Including 40x SAS Expander!

RAID configuration1x HBA- or RAID-Controllers. Refer to section "RAID" for options.

ODD / Backup3x 1.6x5.25" bays are available for an optical and/or backup drives in the upper drive area.

HD cage upgrades

Upgrade kit for the upper drive area

Please refer to “Upgrade kit for the upper drive area with PYT2557TBN/ PYT2557R2N/ PYT2557TCN/ PYT2557RAN

cnfgTX2550M7-20231117__cagePage 15 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

The mix configuration information

Upgrade kit for the upper drive area with PYT2557TBN/ PYT2557R2N/ PYT2557TCN/ PYT2557RAN

Only one of them can be selected.

Upgrade kit for 8x2.5" HDD

PYBBA28SS

8x2.5"

PY-BA28SS

Upgrade kit for 8x2.5" HDD(SAS4)8x2.5" combo HDD

Note!

This option requires 2x CPUs.

This option requires min. 1x 24Gb/s PRAID/HBA

In total, 2x PRAID/ HBA are allowed (1x for bottom / mid area,

1x for upper area). Choose from the options below:

PYBBA28ST

[Option 1] – Choose two of the following:

- 1x for bottom / mid area :

PRAID EP 325x-xi [PYBSR4MA1L/PY-

SR4MA1/PYBSR4MA2L/PY-SR4MA2/PYBSR4MA3L/PY-

SR4MA3],

or PSAS CP 2200-16i [PYBSC4MA1L/PY-SC4MA1]

or PSAS CP 2100-8i [PYBSC3MA2L/PY-SC3MA2].

- 1x for upper area :

PRAID EP 325x-xi [PYBSR4MA1L/PY-

SR4MA1/PYBSR4MA2L/PY-SR4MA2/PYBSR4MA3L/PY-

SR4MA3],

or PSAS CP 2200-16i [PYBSC4MA1L/PY-SC4MA1]

PY-BA28ST

[Option 2] – Choose two of the following:

- 1x for bottom / mid area :

PSAS CP600i[PYBSC4FAL/PY-SC4FA],

or PRAID CP600i[PYBSR4FAL/PY-SR4FA],

or PRAID EP740i[PYBSR4C71L/PY-SR4C71],

or PRAID EP6x0i[PYBSR4C63L/PY-SR4C63/PYBSR4C6L/PY-

SR4C6]

- 1x for upper area :

Upgrade kit for 1-4 x2.5" PCIe SSD SFF w/

PYBBA24PJ

8x2.5" combo HDD

onBoard

PY-BA24PJ

Upgrade kit for 1-4 x2.5" PCIe SSD SFF w/

PYBBA24PK

8x2.5" combo HDD

PRAID

Note!

PY-BA24PK

This option requires 1x PRAID for NVMe.

upgrade kit for 5-8 x2.5" PCIe SSD SFF w/

PYBCBE024

Note!

onBoardThis option requires 2x CPUs.

PY-CBE024

This option requires PYBBA24PJ.

Upgrade kit for 5-8 x2.5" PCIe SSD SFF w/ Note!

PRAID

PYBCBE025

This option requires 2x CPUs.

PY-CBE025

This option requires another PRAID for NVMe.

This option requires PYBBA24PK.

RAID configurationHBA- or RAID- or Retimer-Controllers. Refer to section "RAID" for options.

ODD / Backup

1x 1.6x5.25" bay is available for an optical or backup drive in the upper drive area.

Note! One of LTO and ODD can be selected.

G

cnfgTX2550M7-20231117__cagePage 16 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

Chapter 7 - SAS / RAID Controller

G

FH PCIe card requires FH PCIe riser card. Please refer to ''Chapter 14 - PCI riser card'.

onboard SATA controller with SW-RAID

onboard controller for SATA HDD or SSD drives

6Gb/s SATAIntel VROC (SATA RAID) based on chipset

BIOS version R1.6.0 or later is required to use Intel VROC (SATA RAID)

No CacheSW-RAID 0, 1, 102xonboard, included

intenal HBA and RAID controller, no 2nd Level cache

internal RAID / HBA controllers for SAS, SATA HDD or SSD drives

RAID 0, 1, 10

PRAID CP600i LPNo Cache

8 ports 3, 6 & 12Gb/s SAS/SATA HDD/SSD, supports up to 8 drives without expander

supports SED (Self Encrypting Drives)

requires 1x LP PCIe 4.0 x8 (int.) slot, based on LSI SAS3808

HBA, no RAID

PSAS CP600i LPNo Cache

16 ports 3, 6 & 12Gb/s SAS/SATA HDD/SSD, supports up to 16 drives without expander

limitation: supports up to 30 drives only with expander

requires 1x LP PCIe 4.0 x8 (int.) slot, based on LSI SAS3816; IT FW stack without RAID functionality

PYBSR4FAL

PY-SR4FA

PYBSC4FALPY-SC4FA

internal RAID / HBA controllers for SAS, SATA HDD or SSD drives

HBA + RAID 0, 1, 10, 5PYBSC4MA1LPY-SC4MA1

No Cache

PSAS CP 2200-16i LP available from 2024/03

16 ports 6, 12 & 24Gb/s SAS/SATA HDD/SSD, supports up to 16 SAS/SATA drives without expander

(the configuration for up to 4 x4 NVMe drives requires a different order number, please see below)

supports SED (Self Encrypting Drives)

requires 1x LP PCIe 4.0 x8 (int.) slot

* max. 2x, when Upgrade kit for 8x2.5" HDD(SAS4): PYBBA28ST is ordered

(FYI: PYBSC4MA1L and PYBSC4MA2(L) are identical products. The 2nd Order number was only introduced for explicite ordering and cabling)

HBA + RAID 0, 1, 10, 5

PSAS CP 2100-8i LPNo Cache

8 ports 3, 6 & 12Gb/s SAS/SATA HDD/SSD, supports up to 8 devices without expander

requires 1x LP PCIe 3.0 x8 (int.) slot

PYBSC3MA2LPY-SC3MA2

internal RAID / HBA controllers for PCIe SSD drives

HBA + RAID 0, 1, 10, 5PYBSC4MA2

No Cache

PSAS CP 2200-16i NVMe FH

available from 2024/03

PY-SC4MA1

HBA + RAID 0, 1, 10, 5PYBSC4MA2L

No Cache

PSAS CP 2200-16i NVMe LP

available from 2024/03

up to 4 x4 NVMe drives are supported. (the configuration for SAS/SATA only requires a different order number, please see above)

requires 1x FH or LP PCIe 4.0 x8 (int.) slot

(FYI: PYBSC4MA1L and PYBSC4MA2(L) are identical products. The 2nd Order number was only introduced for explicite ordering and cabling)

internal RAID controller with 2nd Level cache

internal RAID controllers for SAS, SATA HDD or SSD drives

PYBSR4C71LPY-SR4C71

PRAID EP740i LP available from 2024/07

4GB Cache

RAID 0, 1, 10, 5, 50, 6, 60

16 ports 6, 12 & 24Gb/s SAS/SATA HDD/SSD, supports up to 16 SAS/SATA drives without expander

(the configuration for up to 4 x4 NVMe drives requires a different order number, please see below)

supports SED (Self Encrypting Drives)

requires 1x LP PCIe 4.0 x8 (int.) slot, based on LSI SAS4116

* max. 2x, when Upgrade kit for 8x2.5" HDD(SAS4): PYBBA28ST is ordered

(FYI: PYBSR4C71L and PYBSR4C72(L) are identical products. The 2nd Order number was only introduced for explicite ordering and cabling)

internal RAID controllers for SAS, SATA HDD or SSD drives

PRAID EP640i LP4GB Cache

RAID 0, 1, 10, 5, 50, 6, 60

8 ports 3, 6 & 12Gb/s SAS/SATA HDD/SSD, supports up to 8 drives without expander

supports SED (Self Encrypting Drives)

requires 1x LP PCIe 4.0 x8 (int.) slot, based on LSI SAS3908

PYBSR4C63LPY-SR4C63

PRAID EP680i LP8GB CachePYBSR4C6LPY-SR4C6

RAID 0, 1, 10, 5, 50, 6, 60

16 ports 3, 6 & 12Gb/s SAS/SATA HDD/SSD, supports up to 16 SAS/SATA drives without expander

(the configuration for up to 4 x4 NVMe drives requires a different order number, please see below)

supports SED (Self Encrypting Drives)

requires 1x LP PCIe 4.0 x8 (int.) slot, based on LSI SAS3916

(FYI: PYBSR4C6L and PYBSR4C62(L) are identical products. The 2nd Order number was only introduced for explicite ordering and cabling)

optional Flash Backup Unit (FBU)

FBU option for PRAID EP6xx / EP7xx: Supercap securing the power supply of the RAID controller in case of

S26361-F4042-E155

power failure including cable with 55cm length

S26361-F4042-L110

cnfgTX2550M7-20231117_IDPage 17 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

internal RAID controllers for PCIe SSD drives

4GB CachePYBSR4C72

PRAID EP740i NVMe FH

available from 2024/07

RAID 0, 1, 10, 5, 50, 6, 60

PY-SR4C71

4GB CachePYBSR4C72L

PRAID EP740i NVMe LP

available from 2024/07

RAID 0, 1, 10, 5, 50, 6, 60

up to 4 x4 NVMe drives are supported. (the configuration for SAS/SATA only requires a different order number, please see above)

requires 1x FH or LP PCIe 4.0 x8 (int.) slot, based on LSI SAS4116

(FYI: PYBSR4C71L and PYBSR4C72(L) are identical products. The 2nd Order number was only introduced for explicite ordering and cabling)

optional Flash Backup Unit (FBU)

S26361-F4042-L110

FBU option for PRAID EP7xx: Supercap securing the power supply of the RAID controller in case of power

S26361-F4042-E155

failure including cable with 55cm length

internal RAID controllers for PCIe SSD drives

PRAID EP680i NVMe FH8GB CachePYBSR4C62

RAID 0, 1, 10, 5, 50, 6, 60

PY-SR4C6

PRAID EP680i NVMe LP8GB CachePYBSR4C62L

RAID 0, 1, 10, 5, 50, 6, 60

up to 4 x4 NVMe drives are supported. (the configuration for SAS/SATA only requires a different order number, please see above)

no FBU is allowed for this controller

requires 1x FH or LP PCIe 4.0 x8 (int.) slot, based on LSI SAS3916

(FYI: PYBSR4C6L and PYBSR4C62(L) are identical products. The 2nd Order number was only introduced for explicite ordering and cabling)

internal RAID controllers for SAS, SATA HDD or SSD drives

PRAID EP 3252-8i LP2GB Cache

RAID 0, 1, 10, 5, 50, 6, 60

PRAID EP 3254-8i LP4GB Cache

RAID 0, 1, 10, 5, 50, 6, 60

8 ports 6, 12 & 24Gb/s SAS/SATA HDD/SSD, supports up to 8 drives without expander

supports SED (Self Encrypting Drives)

requires 1x LP PCIe 4.0 x8 (int.) slot

* max. 2x, when Upgrade kit for 8x2.5" HDD(SAS4): PYBBA28ST is ordered

PYBSR4MA1L

PYBSR4MA2L

PY-SR4MA1

PY-SR4MA2

PRAID EP 3258-16i LP8GB CachePYBSR4MA3LPY-SR4MA3

RAID 0, 1, 10, 5, 50, 6, 60

16 ports 6, 12 & 24Gb/s SAS/SATA HDD/SSD, supports up to 16 SAS/SATA drives without expander

(the configuration for up to 4 x4 NVMe drives requires a different order number, please see below)

supports SED (Self Encrypting Drives)

requires 1x LP PCIe 4.0 x8 (int.) slot

* max. 2x, when Upgrade kit for 8x2.5" HDD(SAS4): PYBBA28ST is ordered

(FYI: PYBSR4MA3L and PYBSR4MA4(L) are identical products. The 2nd Order number was only introduced for explicite ordering and cabling)

optional Flash Backup Unit (FBU)

FBU option for PRAID EP 325x in rear PCIe Slot#1: Supercap securing the power supply of the RAID

controller in case of power failure without extension cable

FBU option for PRAID EP 325x in rear PCIe Slot#8: Supercap securing the power supply of the RAID

controller in case of power failure including cable with 46cm length

PYBFBM014

PYBFBM012

PY-FBM01

PY-FBM01

internal RAID controllers for PCIe SSD drives

PRAID EP 3258-16i NVMe FH8GB CachePYBSR4MA4

RAID 0, 1, 10, 5, 50, 6, 60

PY-SR4MA3

PRAID EP 3258-16i NVMe LP8GB CachePYBSR4MA4L

RAID 0, 1, 10, 5, 50, 6, 60

available from 2024/03

up to 4 x4 NVMe drives are supported. (the configuration for SAS/SATA only requires a different order number, please see above)

requires 1x FH or LP PCIe 4.0 x8 (int.) slot

(FYI: PYBSR4MA3L and PYBSR4MA4(L) are identical products. The 2nd Order number was only introduced for explicite ordering and cabling)

optional Flash Backup Unit (FBU) available from 2024/03

FBU option for PRAID EP 325x in rear PCIe Slot#3/#4/#8: Supercap securing the power supply of the RAID

PYBFBM012

controller in case of power failure including cable with 46cm length

PY-FBM01

FBU cannot be combined with Advanced Thermal design.

up to 3x FBU can be integrated per System

Group A and Group B cannot be mixed

Group A and Group C can be mixed

Group B and Group C can be mixed

Group AGroup B

PSAS CP600iPSAS CP 2100-8i

PSAS CP600i for LTOPSAS CP 2200-16i

PRAID CP600iPSAS CP 2200-16i NVMe

PRAID EP740iPSAS CP 2200-16i for LTO

PRAID EP740i NVMePRAID EP 3252-8i

PRAID EP640iPRAID EP 3254-8i

PRAID EP680iPRAID EP 3258-16i

PRAID EP680i NVMePRAID EP 3258-16i NVMe

Group C

PSAS CP600e

PRAID EP680e

cnfgTX2550M7-20231117_IDPage 18 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

H

external HBA controller, no 2nd Level cache

external HBA controllers for SAS HDD or SSD drives

HBA, no RAID

PSAS CP600e FHNo Cache

HBA, no RAID

PSAS CP600e LPNo Cache

16 ports 3, 6 & 12Gb/s SAS/SATA HDD/SSD, 4x SFF8644 (external Mini-SAS HD)

requires 1x FH or LP PCIe 4.0 x8 (int.) slot, based on LSI SAS3816

PYBSC4FAE

PYBSC4FAEL

PY-SC4FAE

external RAID controller with 2nd Level cache

external RAID controllers for SAS HDD or SSD drives

PRAID EP680e FH8GB CacheRAID 0, 1, 10, 5, 50, 6, 60

PRAID EP680e LP8GB CacheRAID 0, 1, 10, 5, 50, 6, 60

8 ports 3, 6 & 12Gb/s SAS/SATA HDD/SSD, 2x SFF8644 (external Mini-SAS HD)

supports SED (Self Encrypting Drives)

requires 1x FH or LP PCIe 4.0 x8 (int.) slot, based on LSI SAS3916

optional Flash Backup Unit (FBU)

FBU option for PRAID EP6xx: Supercap securing the power supply of the RAID controller in case of power

failure including cable with 55cm length

PYBSR4C6E

PYBSR4C6EL

PY-SR4C6E

S26361-F4042-E155S26361-F4042-L110

internal controller for PCIe SSD (NVMe SSD), no HW-RAID

internal controller for PCIe SSD (NVMe SSD)

PCIeIntel CPUNo Cache

optional Licence Activation Key for Intel VROC (VMD NVMe RAID)

No Cache

Intel VROC Upgrade Key Premium

Intel CPU

BIOS version R1.6.0 or later is required to use Intel VROC (VMD NVMe RAID)

* RAID 1 is only supported In VMware ESXi.

I

No HW-RAID

SW-RAID 0, 1, 10, 5 *

-

1x

onboard, included

PYBRLVR02PY-RLVR02

cnfgTX2550M7-20231117_IDPage 19 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

Chapter 8 - ODD optical disk drives

PRIMERGY TX2550 M7offers up to 3x 1.6” bays (located in the upper side of Tower-/ right side of Rack-server) for various ODD's and/or backup drives.

Depending on the HDD drive cage configuration there may be some or all of 1.6” bays already occupied;please find the number of availablebays in the chapter 6, "HD-cage", incl. further configuration details.

I1

12x 3.5" configuration

with 1x 9.5mm bay

I2

Configurations

with min. 1x free 1.6" bay

S26361-F3778-E1

S26361-F3778-L1

DVD-RW supermulti ultra slim

all formats, DUAL/DL, DVD-

RAM only W2K, W3K and

Linux

S26361-F3641-E6

S26361-F3641-L6

Blu-ray Triple Writer ultra slim

6x BD-RW, 8x DVD, 24x CD,

BD DL and all CD/DVD

formats

will be EOL in CQ2'24

S26361-F3266-E2

S26361-F3266-L2

DVD-ROM

DVD-ROM or CD-ROM

will be EOL in CQ2'24

S26361-F3267-E2

S26361-F3267-L2

DVD-RW supermulti SATA

all formats, DUAL/DL, DVD-

RAM only W2K, W3K and Linux

S26361-F3641-E8

S26361-F3641-L8

Blu-ray Triple Writer SATA

6x BD-RW, 8x DVD, 24x CD, BD

DL and all CD/DVD formats.

9.5mm ultra slim drive integrated

into a 5.25" bay.

9.5mm, black bezel

max. 1x per system

9.5mm, black bezel

max. 1x per system

1.6" * 5.25" black bezel

max. 1x per system

1.6" * 5.25" black bezel

max. 1x per system

9.5mm at 1.6" *5.25" black bezel

max. 1x per system

will be available in CQ2'24will be available in CQ2'24

PYBDV122PYBDR122

PY-DV122PY-DR122

DVD-ROMDVD-RW supermulti SATA

DVD-ROM or CD-ROMall formats, DUAL/DL, DVD-

RAM only W2K, W3K and Linux

9.5mm at 1.6" *5.25" black bezel

max. 1x per system

9.5mm at 1.6" *5.25" black bezel

max. 1x per system

J

cnfgTX2550M7-20231117_DPage 20 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

Chapter 9 - backup drives

With mostconfigurations the TX2550 M7 offers 3 x 1.6” bay in the accessible drives area located at the top of the Tower Server (or at the right side of the Rack) for various ODD and or backup drives.

Depending on the HDD drive configuration there may be some or all of these 1.6” bays already occupied-please find the number of availablebays and the size listed as point 3)at each of the drive

bundles. All bundles with limitations are highlighted with 2 exclamation marks in the front (e.g. "!! 1x 9.5mm ...")

J

Config. with min. 1x free 1.6" bay

SAS HBA card for Internal LTO drives

Note: In case SATA/SAS/NVMe with Raid card and PCI Riser rights(PYBPRE638/PY-PRE638/PYBPRE641/PY-PRE641/PYBPRE848/PY-PRE848/PYBPRE643/PY-

PRE643/PYBPRE645/PY-PRE645/PYBPRE851/PY-PRE851) exists, this can't be used.

SAS HBA Controller

PYBSC4FA2LPY-SC4FA

PSAS CP600i LP for LTO

requires 1x LP PCIe 4.0 x8 / for LTO drives1x

PYBSC4MA3LPY-SC4MA1

PSAS CP 2200-16i LP for LTO

requires 1x LP PCIe 4.0 x8 / for LTO drives available from 2024/031x

LTO drives (Need to select one of LTO drives togheter with SAS HBA)

LTO drives are not including tape drives. Cleaning Cartridge and Cables are included

LTO 7 tape drive (w/o tape)

6.0TB, 300MB/s, SAS 2.0, 5.25 inch/HalfHeight

LTO 8 tape drive (w/o tape)

12.0TB, 300MB/s, SAS 2.0, 5.25 inch/HalfHeight

LTO 9 tape drive (w/o tape)

18.0TB, 300MB/s, SAS 3.0, 5.25 inch/HalfHeight

1x

1x

1x

S26361-F5606-E1

S26361-F5789-E1

PYBLT911

S26361-F5606-L1

S26361-F5789-L1

PY-LT911

RDX drives

RDX drive is not including Cartridge.

RDX Drive cage (w/o cartriges)

USB 3.0, 5.25 inch / Half Height

RDX

RDX Cartrridge

RDX Cartridge 500GB

RDX Cartridge 1TB

RDX Cartridge 2TB

RDX Cartridge 4TB

1x

S26361-F3750-E4S26361-F3750-L4

-

-

-

-

-

-

-

-

S26361-F3857-L500

S26361-F3857-L600

S26361-F3857-L700

S26361-F3857-L900

K

cnfgTX2550M7-20231117_ckupPage 21 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

Chapter 10 - storage drives

SAS drives and SATA drives can be mixed, but cannot be used in one logical RAID volume.

SATA drives can be connected to the onboard Controller (max. 8x),

SAS drives require a dedicated SAS / RAID Controller

PCIe-SSDs can be connected to the onboard Controller, or require a dedicated RAID Controller or PCIe retimer/switch card.

Hard Disk Sector Format Information:

512n HDD: 512 byte sectors on the drive media.

512e (e=emulation) HDD: 4K physical sectors on the drive media with 512 byte logical configuration.

512e HDD Disk Drives: VMware 6.0 or earlier is not supported.

When using SSDs with VMware ESXi, select the SSDs that meet the endurance requirement describedin

KB2145210 below.

/kb/2145210

DWPD: Drive Writes Per Day over 5 years.

SED/FIPS are Self Encrypting Drives, and they require either a RAID controller with ®SafeStore (SED) support or an HBA and

in addition a software instance, supporting SED Key Management.

It is strongly recommended to order SafeStore (SED) RAID controller with SEDHDD or SSD devices for SafeStore (SED) functionality.

Non-SED drives and SED/FIPS drives can be mixed, but cannot be used in one logical RAID volume.

HDD Classes:

Business-Critical (BC) -SATA=Nearline SATA Enterprise Drives / 7.2Krpm,SATA 6G.

Business-Critical (BC) -SAS=Nearline SAS Enterprise Drives / 7.2Krpm,SAS 12G.

Mission-Critical (MC)=SAS 10K and SAS 15K Enterprise Drives with max. performance and reliability.

Warranty:

SSD and SATA DOM have a built-in Wear-Out indicator. In this case the warranty for such a component, as an

exception to the system warranty, is restricted to the time period until the indicator reaches the exhaust level.

K

2.5" (SFF) SAS and SATA SSD

SSD SAS 2.5" Write Intensive

(SFF) Enterprise with hot plug/hot replace tray

based on Kioxia PM7 drives

CapacityFormfactor

InterfaceEnduranceDWPDorder code E-partorder code L-part

800GB2.5" (SFF)

SAS 24Gb/sWrite Intensive10

PYBSS80NGFPY-SS80NGF

1.6TB2.5" (SFF)

SAS 24Gb/sWrite Intensive10

PYBSS16NGFPY-SS16NGF

800GB2.5" (SFF)

SAS 24Gb/sWrite Intensive10

SED FIPS available in CY24Q1

PYBSS80NGGPY-SS80NGG

1.6TB2.5" (SFF)

SAS 24Gb/sWrite Intensive10

SED FIPS available in CY24Q1

PYBSS16NGGPY-SS16NGG

max. 8x, 16x, 24x or 32x - depending on base unit & configuration

SSD SAS 2.5" Write Intensive

(SFF) Enterprise with hot plug/hot replace tray

based on Seagate Nytro3732/3750 drives

CapacityFormfactor

InterfaceEnduranceDWPDorder code E-partorder code L-part

400GB 2.5" (SFF)

SAS 12Gb/sWrite Intensive10

PYBSS40NGAPY-SS40NGA

800GB2.5" (SFF)

SAS 12Gb/sWrite Intensive10

PYBSS80NGAPY-SS80NGA

1.6TB2.5" (SFF)

SAS 12Gb/sWrite Intensive10

PYBSS16NGAPY-SS16NGA

400GB 2.5" (SFF)

SAS 12Gb/sWrite Intensive10 SED

PYBSS40NGWPY-SS40NGW

800GB2.5" (SFF)

SAS 12Gb/sWrite Intensive10 SED

PYBSS80NGWPY-SS80NGW

1.6TB2.5" (SFF)

SAS 12Gb/sWrite Intensive10 SED

PYBSS16NGWPY-SS16NGW

max. 8x, 16x, 24x or 32x - depending on base unit & configuration

SSD SAS 2.5" Mixed Use

(SFF) Enterprise with hot plug/hot replace tray

based on Kioxia PM7 drives

CapacityFormfactor

InterfaceEnduranceDWPDorder code E-partorder code L-part

1.6TB2.5" (SFF)

SAS 24Gb/sMixed Use3

PYBSS16NPMPY-SS16NPM

3.2TB2.5" (SFF)

SAS 24Gb/sMixed Use3

PYBSS32NPMPY-SS32NPM

6.4TB2.5" (SFF)

SAS 24Gb/sMixed Use3

PYBSS64NPMPY-SS64NPM

max. 8x, 16x, 24x or 32x - depending on base unit & configuration

SSD SAS 2.5" Mixed Use

(SFF) Enterprise with hot plug/hot replace tray

based on Seagate Nytro3532/3550 drives

CapacityFormfactor

InterfaceEnduranceDWPDorder code E-partorder code L-part

800GB2.5" (SFF)

SAS 12Gb/sMixed Use3

PYBSS80NPFPY-SS80NPF

1.6TB2.5" (SFF)

SAS 12Gb/sMixed Use3

PYBSS16NPFPY-SS16NPF

3.2TB2.5" (SFF)

SAS 12Gb/sMixed Use3

PYBSS32NPFPY-SS32NPF

6.4TB2.5" (SFF)

SAS 12Gb/sMixed Use3

PYBSS64NPFPY-SS64NPF

max. 8x, 16x, 24x or 32x - depending on base unit & configuration

cnfgTX2550M7-20231117__SSDPage 22 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

SSD SAS 2.5" Read Intensive

(SFF) Enterprise with hot plug/hot replace tray

based on Kioxia PM7 drives

CapacityFormfactor

InterfaceEnduranceDWPDorder code E-partorder code L-part

1.92TB 2.5" (SFF)

SAS 24Gb/sRead Intensive1

PYBSS19NNMPY-SS19NNM

3.84TB 2.5" (SFF)

SAS 24Gb/sRead Intensive1

PYBSS38NNLPY-SS38NNL

7.68TB 2.5" (SFF)

SAS 24Gb/sRead Intensive1

PYBSS76NNMPY-SS76NNM

15.36TB 2.5" (SFF)

SAS 24Gb/sRead Intensive1

PYBSS15NNLPY-SS15NNL

7.68TB 2.5" (SFF)

SAS 24Gb/sRead Intensive1

SED FIPS available in CY24Q1

PYBSS76NNNPY-SS76NNN

15.36TB 2.5" (SFF)

SAS 24Gb/sRead Intensive1

SED FIPS available in CY24Q1

PYBSS15NNMPY-SS15NNM

max. 8x, 16x, 24x or 32x - depending on base unit & configuration

will be available in CQ4'23

SSD SAS 2.5" Read Intensive

(SFF) Enterprise with hot plug/hot replace tray

based on Samsung PM1653 drives

CapacityFormfactor

InterfaceEnduranceDWPDorder code E-partorder code L-part

960GB 2.5" (SFF)

SAS 24Gb/sRead Intensive1 SED

PYBSS96NNMPY-SS96NNM

1.92TB 2.5" (SFF)

SAS 24Gb/sRead Intensive1 SED

PYBSS19NNPPY-SS19NNP

3.84TB 2.5" (SFF)

SAS 24Gb/sRead Intensive1 SED

PYBSS38NNNPY-SS38NNN

7.68TB 2.5" (SFF)

SAS 24Gb/sRead Intensive1 SED

PYBSS76NNPPY-SS76NNP

15.36TB 2.5" (SFF)

SAS 24Gb/sRead Intensive1 SED

PYBSS15NNNPY-SS15NNN

This SSDs can be used as Non-SED drives, but it requires a RAID controller with SED support for using as SED drives.

max. 8x, 16x, 24x or 32x - depending on base unit & configuration

SSD SAS 2.5" Read Intensive

(SFF) Enterprise with hot plug/hot replace tray

based on Seagate Nytro3332/3350 drives

CapacityFormfactor

InterfaceEnduranceDWPDorder code E-partorder code L-part

960GB 2.5" (SFF)

SAS 12Gb/sRead Intensive1

PYBSS96NNJPY-SS96NNJ

1.92TB 2.5" (SFF)

SAS 12Gb/sRead Intensive1

PYBSS19NNHPY-SS19NNH

3.84TB 2.5" (SFF)

SAS 12Gb/sRead Intensive1

PYBSS38NNHPY-SS38NNH

7.68TB 2.5" (SFF)

SAS 12Gb/sRead Intensive1

PYBSS76NNHPY-SS76NNH

15.36TB 2.5" (SFF)

SAS 12Gb/sRead Intensive1

PYBSS15NNGPY-SS15NNG

max. 8x, 16x, 24x or 32x - depending on base unit & configuration

will be available in CQ1'24

SSD SATA 2.5" Mixed Use (SFF)

Enterprise with hot plug/hot replace tray

based on Samsung PM897a drives

CapacityFormfactor

InterfaceEnduranceDWPDorder code E-partorder code L-part

480GB2.5" (SFF)

SATA 6Gb/sMixed Use3 SED

PYBSS48NKSPY-SS48NKS

960GB2.5" (SFF)

SATA 6Gb/sMixed Use3 SED

PYBSS96NKSPY-SS96NKS

1.92TB2.5" (SFF)

SATA 6Gb/sMixed Use3 SED

PYBSS19NKSPY-SS19NKS

3.84TB2.5" (SFF)

SATA 6Gb/sMixed Use3 SED

PYBSS38NKSPY-SS38NKS

This SSDs can be used as Non-SED drives, but it requires a RAID controller with SED support for using as SED drives.

max. 8x, 16x, 24x or 32x - depending on base unit & configuration

SSD SATA 2.5" Mixed Use (SFF)

Enterprise with hot plug/hot replace tray

based on Samsung PM897 drives

CapacityFormfactor

InterfaceEnduranceDWPDorder code E-partorder code L-part

480GB2.5" (SFF)

SATA 6Gb/sMixed Use3

PYBSS48NKQPY-SS48NKQ

960GB2.5" (SFF)

SATA 6Gb/sMixed Use3

PYBSS96NKQPY-SS96NKQ

1.92TB2.5" (SFF)

SATA 6Gb/sMixed Use3

PYBSS19NKQPY-SS19NKQ

3.84TB2.5" (SFF)

SATA 6Gb/sMixed Use3

PYBSS38NKQPY-SS38NKQ

max. 8x, 16x, 24x or 32x - depending on base unit & configuration

SSD SATA 2.5" Mixed Use (SFF)

Enterprise with hot plug/hot replace tray

based on Micron 5300/5400 MAX drives

CapacityFormfactor

InterfaceEnduranceDWPDorder code E-partorder code L-part

480GB2.5" (SFF)

SATA 6Gb/sMixed Use5,0

S26361-F5776-E480S26361-F5776-L480

960GB2.5" (SFF)

SATA 6Gb/sMixed Use5,0

S26361-F5776-E960S26361-F5776-L960

1.92TB2.5" (SFF)

SATA 6Gb/sMixed Use5,0

S26361-F5776-E192S26361-F5776-L192

3.84TB2.5" (SFF)

SATA 6Gb/sMixed Use3,5

S26361-F5776-E384S26361-F5776-L384

max. 8x, 16x, 24x or 32x - depending on base unit & configuration

will be available in CQ1'24

cnfgTX2550M7-20231117__SSDPage 23 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

SSD SATA 2.5" Read Intensive (SFF)

Enterprise with hot plug/hot replace tray

based on Samsung PM893a drives

CapacityFormfactor

InterfaceEnduranceDWPDorder code E-partorder code L-part

480GB2.5" (SFF)

SATA 6Gb/sRead Intensive1,0 SED

PYBSS48NMEPY-SS48NME

960GB2.5" (SFF)

SATA 6Gb/sRead Intensive1,0 SED

PYBSS96NMEPY-SS96NME

1.92TB2.5" (SFF)

SATA 6Gb/sRead Intensive1,0 SED

PYBSS19NMEPY-SS19NME

3.84TB2.5" (SFF)

SATA 6Gb/sRead Intensive1,0 SED

PYBSS38NMEPY-SS38NME

7.68TB2.5" (SFF)

SATA 6Gb/sRead Intensive1,0 SED

PYBSS76NMEPY-SS76NME

This SSDs can be used as Non-SED drives, but it requires a RAID controller with SED support for using as SED drives.

max. 8x, 16x, 24x or 32x - depending on base unit & configuration

SSD SATA 2.5" Read Intensive (SFF)

Enterprise with hot plug/hot replace tray

based on Samsung PM893 drives

CapacityFormfactor

InterfaceEnduranceDWPDorder code E-partorder code L-part

240GB2.5" (SFF)

SATA 6Gb/sRead Intensive1,0

PYBSS24NMDPY-SS24NMD

480GB2.5" (SFF)

SATA 6Gb/sRead Intensive1,0

PYBSS48NMDPY-SS48NMD

960GB2.5" (SFF)

SATA 6Gb/sRead Intensive1,0

PYBSS96NMDPY-SS96NMD

1.92TB2.5" (SFF)

SATA 6Gb/sRead Intensive1,0

PYBSS19NMDPY-SS19NMD

3.84TB2.5" (SFF)

SATA 6Gb/sRead Intensive1,0

PYBSS38NMDPY-SS38NMD

7.68TB2.5" (SFF)

SATA 6Gb/sRead Intensive1,0

PYBSS76NMDPY-SS76NMD

max. 8x, 16x, 24x or 32x - depending on base unit & configuration

SSD SATA 2.5" Read Intensive (SFF)

Enterprise with hot plug/hot replace tray

based on Micron 5300/5400PRO drives

CapacityFormfactor

InterfaceEnduranceDWPDorder code E-partorder code L-part

240GB2.5" (SFF)

SATA 6Gb/sRead Intensive1,5

S26361-F5783-E240S26361-F5783-L240

480GB2.5" (SFF)

SATA 6Gb/sRead Intensive1,5

S26361-F5783-E480S26361-F5783-L480

960GB2.5" (SFF)

SATA 6Gb/sRead Intensive1,5

S26361-F5783-E960S26361-F5783-L960

1.92TB2.5" (SFF)

SATA 6Gb/sRead Intensive1,5

S26361-F5783-E192S26361-F5783-L192

3.84TB2.5" (SFF)

SATA 6Gb/sRead Intensive1,2

S26361-F5783-E384S26361-F5783-L384

7.68TB2.5" (SFF)

SATA 6Gb/sRead Intensive0,6

S26361-F5783-E768S26361-F5783-L768

max. 8x, 16x, 24x or 32x - depending on base unit & configuration

L1

2.5" (SFF) Hard drives

EOL, as long as stock available

HDD SAS 2.5"

15K

(SFF) Enterprise Mission Critical with hot plug/hot replace tray

CapacityRPM

InterfaceSectororder code E-partorder code L-part

300GB

15 000SAS 12Gb/s512n

S26361-F5727-E530S26361-F5727-L530

600GB

15 000SAS 12Gb/s512n

S26361-F5727-E560S26361-F5727-L560

900GB

15 000SAS 12Gb/s512n

S26361-F5531-E590S26361-F5531-L590

max. 8x, 16x, 24x or 32x - depending on base unit & configuration

HDD SAS 2.5" 10K 512n

(SFF) Enterprise Mission Critical with hot plug/hot replace tray

CapacityRPM

InterfaceSectororder code E-partorder code L-part

300GB

10 000SAS 12Gb/s512n

S26361-F5729-E130S26361-F5729-L130

600GB

10 000SAS 12Gb/s512n

S26361-F5729-E160S26361-F5729-L160

1.2TB

10 000SAS 12Gb/s512n

S26361-F5729-E112S26361-F5729-L112

300GB

10 000SAS 12Gb/s512n SED

PYBSH301EUPY-SH301EU

600GB

10 000SAS 12Gb/s512n SED

PYBSH601EUPY-SH601EU

1.2TB

10 000SAS 12Gb/s512n SED

PYBSH121EUPY-SH121EU

max. 8x, 16x, 24x or 32x - depending on base unit & configuration

HDD SAS 2.5" 10K 512e

(SFF) Enterprise Mission Critical with hot plug/hot replace tray

CapacityRPM

InterfaceSectororder code E-partorder code L-part

1.8TB

10 000SAS 12Gb/s512e

S26361-F5730-E118S26361-F5730-L118

2.4TB

10 000SAS 12Gb/s512e

S26361-F5543-E124S26361-F5543-L124

1.8TB

10 000SAS 12Gb/s512e SED

PYBSH181DUPY-SH181DU

2.4TB

10 000SAS 12Gb/s512e SED

S26361-F5582-E124S26361-F5582-L124

max. 8x, 16x, 24x or 32x - depending on base unit & configuration

EOL, as long as stock available

HDD SAS 2.5" 7.2K 512n

(SFF) Enterprise Business Critical with hot plug/hot replace tray

CapacityRPM

InterfaceSectororder code E-partorder code L-part

1TB

7 200SAS 12Gb/s512n

S26361-F5600-E100S26361-F5600-L100

2TB

7 200SAS 12Gb/s512n

S26361-F5600-E200S26361-F5600-L200

max. 8x, 16x, 24x or 32x - depending on base unit & configuration

EOL, as long as stock available

HDD SATA 2.5" 7.2K 512n

(SFF) Enterprise Business Critical with hot plug/hot replace tray

CapacityRPM

InterfaceSectororder code E-partorder code L-part

1TB

7 200SATA 6Gb/s512n

S26361-F3956-E100S26361-F3956-L100

2TB

7 200SATA 6Gb/s512n

S26361-F3956-E200S26361-F3956-L200

max. 8x, 16x, 24x or 32x - depending on base unit & configuration

L2

cnfgTX2550M7-20231117__SSDPage 24 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

L2

3.5" (LFF) SATA SSD

will be available in CQ1'24

SSD SATA 3.5" Mixed Use

(LFF) 2.5" SSD Enterprise with 3.5" hot plug/hot replace tray

based on Samsung PM897a drives

CapacityFormfactor

InterfaceEnduranceDWPDorder code E-partorder code L-part

480GB3.5" (LFF)

SATA 6Gb/sMixed Use3 SED

PYBTS48NK9PY-TS48NK9

960GB3.5" (LFF)

SATA 6Gb/sMixed Use3 SED

PYBTS96NK9PY-TS96NK9

1.92TB3.5" (LFF)

SATA 6Gb/sMixed Use3 SED

PYBTS19NK9PY-TS19NK9

3.84TB3.5" (LFF)

SATA 6Gb/sMixed Use3 SED

PYBTS38NK9PY-TS38NK9

This SSDs can be used as Non-SED drives, but it requires a RAID controller with SED support for using as SED drives.

max. 4x, 8x, or 12x - depending on base unit & configuration

SSD SATA 3.5" Mixed Use

(LFF) 2.5" SSD Enterprise with 3.5" hot plug/hot replace tray

based on Samsung PM897 drives

CapacityFormfactor

InterfaceEnduranceDWPDorder code E-partorder code L-part

480GB3.5" (LFF)

SATA 6Gb/sMixed Use3

PYBTS48NK8PY-TS48NK8

960GB3.5" (LFF)

SATA 6Gb/sMixed Use3

PYBTS96NK8PY-TS96NK8

1.92TB3.5" (LFF)

SATA 6Gb/sMixed Use3

PYBTS19NK8PY-TS19NK8

3.84TB3.5" (LFF)

SATA 6Gb/sMixed Use3

PYBTS38NK8PY-TS38NK8

max. 4x, 8x, or 12x - depending on base unit & configuration

SSD SATA 3.5" Mixed Use (LFF)

2.5" SSD Enterprise with 3.5" hot plug/hot replace tray

based on Micron 5300/5400 MAX drives

CapacityFormfactor

InterfaceEnduranceDWPDorder code E-partorder code L-part

480GB2.5" (SFF)

SATA 6Gb/sMixed Use5,0

S26361-F5775-E480S26361-F5775-L480

960GB2.5" (SFF)

SATA 6Gb/sMixed Use5,0

S26361-F5775-E960S26361-F5775-L960

1.92TB2.5" (SFF)

SATA 6Gb/sMixed Use5,0

S26361-F5775-E192S26361-F5775-L192

3.84TB2.5" (SFF)

SATA 6Gb/sMixed Use3,5

S26361-F5775-E384S26361-F5775-L384

max. 4x, 8x, or 12x - depending on base unit & configuration

will be available in CQ1'24

SSD SATA 3.5" Read Intensive (LFF)

2.5" SSD Enterprise with 3.5" hot plug/hot replace tray

based on Samsung PM893a drives

CapacityFormfactor

InterfaceEnduranceDWPDorder code E-partorder code L-part

480GB3.5" (LFF)

SATA 6Gb/sRead Intensive1,0 SED

PYBTS48NMBPY-TS48NMB

960GB3.5" (LFF)

SATA 6Gb/sRead Intensive1,0 SED

PYBTS96NMAPY-TS96NMA

1.92TB3.5" (LFF)

SATA 6Gb/sRead Intensive1,0 SED

PYBTS19NMAPY-TS19NMA

3.84TB3.5" (LFF)

SATA 6Gb/sRead Intensive1,0 SED

PYBTS38NMAPY-TS38NMA

7.68TB3.5" (LFF)

SATA 6Gb/sRead Intensive1,0 SED

PYBTS76NMAPY-TS76NMA

This SSDs can be used as Non-SED drives, but it requires a RAID controller with SED support for using as SED drives.

max. 4x, 8x, or 12x - depending on base unit & configuration

SSD SATA 3.5" Read Intensive (LFF)

2.5" SSD Enterprise with 3.5" hot plug/hot replace tray

based on Samsung PM893 drives

CapacityFormfactor

InterfaceEnduranceDWPDorder code E-partorder code L-part

240GB3.5" (LFF)

SATA 6Gb/sRead Intensive1,0

PYBTS24NM9PY-TS24NM9

480GB3.5" (LFF)

SATA 6Gb/sRead Intensive1,0

PYBTS48NM9PY-TS48NM9

960GB3.5" (LFF)

SATA 6Gb/sRead Intensive1,0

PYBTS96NM9PY-TS96NM9

1.92TB3.5" (LFF)

SATA 6Gb/sRead Intensive1,0

PYBTS19NM9PY-TS19NM9

3.84TB3.5" (LFF)

SATA 6Gb/sRead Intensive1,0

PYBTS38NM9PY-TS38NM9

7.68TB3.5" (LFF)

SATA 6Gb/sRead Intensive1,0

PYBTS76NM9PY-TS76NM9

max. 4x, 8x, or 12x - depending on base unit & configuration

SSD SATA 3.5" Read Intensive (LFF)

2.5" SSD Enterprise with 3.5" hot plug/hot replace tray

based on Micron 5300/5400 PRO drives

CapacityFormfactor

InterfaceEnduranceDWPDorder code E-partorder code L-part

240GB2.5" (SFF)

SATA 6Gb/sRead Intensive1,5

S26361-F5782-E240S26361-F5782-L240

480GB2.5" (SFF)

SATA 6Gb/sRead Intensive1,5

S26361-F5782-E480S26361-F5782-L480

960GB2.5" (SFF)

SATA 6Gb/sRead Intensive1,5

S26361-F5782-E960S26361-F5782-L960

1.92TB2.5" (SFF)

SATA 6Gb/sRead Intensive1,5

S26361-F5782-E192S26361-F5782-L192

3.84TB2.5" (SFF)

SATA 6Gb/sRead Intensive1,2

S26361-F5782-E384S26361-F5782-L384

7.68TB2.5" (SFF)

SATA 6Gb/sRead Intensive0,6

S26361-F5782-E768S26361-F5782-L768

max. 4x, 8x, or 12x - depending on base unit & configuration

cnfgTX2550M7-20231117__SSDPage 25 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

3.5" (LFF) Hard drives

EOL, as long as stock available

HDD SAS 3.5"

15K

(LFF) 2.5" HDD Enterprise Mission Critical with 3.5" hot plug/hot replace tray

CapacityRPM

InterfaceSectororder code E-partorder code L-part

300GB

15 000SAS 12Gb/s512n

S26361-F5726-E530S26361-F5726-L530

600GB

15 000SAS 12Gb/s512n

S26361-F5726-E560S26361-F5726-L560

900GB

15 000SAS 12Gb/s512n

S26361-F5532-E590S26361-F5532-L590

max. 4x, 8x, or 12x - depending on base unit & configuration

HDD SAS 3.5"

10K 512n

(LFF) 2.5" HDD Enterprise Mission Critical with 3.5" hot plug/hot replace tray

CapacityRPM

InterfaceSectororder code E-partorder code L-part

300GB

10 000SAS 12Gb/s512n

S26361-F5728-E130S26361-F5728-L130

600GB

10 000SAS 12Gb/s512n

S26361-F5728-E160S26361-F5728-L160

1.2TB

10 000SAS 12Gb/s512n

S26361-F5728-E112S26361-F5728-L112

max. 4x, 8x, or 12x - depending on base unit & configuration

HDD SAS 3.5"

10K 512e

(LFF) 2.5" HDD Enterprise Mission Critical with 3.5" hot plug/hot replace tray

CapacityRPM

InterfaceSectororder code E-partorder code L-part

1.8TB

10 000SAS 12Gb/s512e

S26361-F5731-E118S26361-F5731-L118

2.4TB

10 000SAS 12Gb/s512e

S26361-F5569-E124S26361-F5569-L124

max. 4x, 8x, or 12x - depending on base unit & configuration

HDD SAS 3.5" 7.2K 512n

(LFF) Enterprise Business critical with hot plug/hot replace tray

CapacityRPM

InterfaceSectororder code E-partorder code L-part

2TB

7 200SAS 12Gb/s512n

PYBCH2T7G4PY-CH2T7G4

4TB

7 200SAS 12Gb/s512n

PYBCH4T7G4PY-CH4T7G4

max. 4x, 8x, or 12x - depending on base unit & configuration

HDD SAS 3.5" 7.2K 512e

(LFF) Enterprise Business Critical with hot plug/hot replace tray

CapacityRPM

InterfaceSectororder code E-partorder code L-part

6TB

7 200SAS 12Gb/s512e

PYBCH6T7B9PY-CH6T7B9

8TB

7 200SAS 12Gb/s512e

S26361-F5635-E800S26361-F5635-L800

12TB

7 200SAS 12Gb/s512e

PYBCHCT7B7PY-CHCT7B7

14TB

7 200SAS 12Gb/s512e

PYBCHET7B6PY-CHET7B6

16TB

7 200SAS 12Gb/s512e

S26361-F5571-E160S26361-F5571-L160

18TB

7 200SAS 12Gb/s512e

PYBCHJT7B2PY-CHJT7B2

20TB

7 200SAS 12Gb/s512eWiil be avairable in CQ1 2024

PYBCHLT7BPY-CHLT7B

6TB

7 200SAS 12Gb/s512e SED

PYBCH6T7BUPY-CH6T7BU

8TB

7 200SAS 12Gb/s512e SED

S26361-F5584-E800S26361-F5584-L800

12TB

7 200SAS 12Gb/s512e SED

PYBCHCT7BWPY-CHCT7BW

14TB

7 200SAS 12Gb/s512e SED

PYBCHET7BVPY-CHET7BV

16TB

7 200SAS 12Gb/s512e SED

S26361-F5624-E160S26361-F5624-L160

18TB

7 200SAS 12Gb/s512e SED

PYBCHJT7BTPY-CHJT7BT

20TB

7 200SAS 12Gb/s512e

FIPS Wiil be avairable in CQ1 2024

PYBCHLT7BSPY-CHLT7BS

max. 4x, 8x, or 12x - depending on base unit & configuration

HDD SATA 3.5" 7.2K 512n

(LFF) Enterprise Business Critical with hot plug/hot replace tray

CapacityRPM

InterfaceSectororder code E-partorder code L-part

1TB

7 200SATA 6Gb/s512n

PYBBH1T7B9PY-BH1T7B9

2TB

7 200SATA 6Gb/s512n

PYBBH2T7B9PY-BH2T7B9

4TB

7 200SATA 6Gb/s512n

PYBBH4T7B9PY-BH4T7B9

max. 4x, 8x, or 12x - depending on base unit & configuration

HDD SATA 3.5" 7.2K 512e

(LFF) Enterprise Business Critical with hot plug/hot replace tray

CapacityRPM

InterfaceSectororder code E-partorder code L-part

6TB

7 200SATA 6Gb/s512e

PYBBH6T7E9PY-BH6T7E9

8TB

7 200SATA 6Gb/s512e

S26361-F5638-E800S26361-F5638-L800

12TB

7 200SATA 6Gb/s512e

PYBBHCT7E4PY-BHCT7E4

14TB

7 200SATA 6Gb/s512e

PYBBHET7E4PY-BHET7E4

16TB

7 200SATA 6Gb/s512e

S26361-F3904-E160S26361-F3904-L160

18TB

7 200SATA 6Gb/s512e

PYBBHJT7E2PY-BHJT7E2

max. 4x, 8x, or 12x - depending on base unit & configuration

L3

cnfgTX2550M7-20231117__SSDPage 26 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

L3

M.2 SATA SSD

M.2 drive for VMware ESXi and for other OSs cannot be mixed

M.2 SATA and M.2 PCIe drive cannot be mixed

SSD SATA M.2 drive for booting, non hot-plug, for VMware ESXi

based on Micron 5300/5400 PRO drives

CapacityFormfactor

InterfaceCategoryorder code E-partorder code L-part

240GBM.2

SATA 6Gb/sBoot

S26361-F5816-E240S26361-F5816-L240

M.2 drive is designed for use as a VMware ESXi boot drive.

max. 1x per Server; in case M.2 drive is installed in connector located on Motherboard (please see folder "description"). VMware ESXi is only supported.

2x M.2 drives required; in case M.2 drives are used with PDUAL CP100 or CP300.

SSD SATA M.2 drive for booting, non hot-plug

based on Micron 5300/5400 PRO drives (960GB is 5400 only)

CapacityFormfactor

InterfaceDWPDCategoryorder code E-partorder code L-part

240GBM.2

SATA 6Gb/s1,5Boot

S26361-F5787-E240S26361-F5787-L240

480GBM.2

SATA 6Gb/s1,5Boot

S26361-F5787-E480S26361-F5787-L480

960GBM.2 2280

SATA 6Gb/s1,5Boot

PYBMF96YNPY-MF96YN

M.2 drive is designed for use as a boot drive with the Endurance Spec. above.

2x M.2 drive for any Hypervisor by the onboard chipset Software RAID is not supported.

max. 2x per Server; in case M.2 drive is installed in connector located on Motherboard (please see folder "description"). VMware is not supported.

2x M.2 drives required; in case M.2 drives are used with PDUAL CP100 or CP300.

SSD PCIe M.2 drive for booting, non hot-plug

based on Micron 7450 PRO drives

CapacityFormfactor

InterfaceDWPDCategoryorder code E-partorder code L-part

480GBM.2 2280

PCIe4.0 x40,9Boot

PYBBS48PEAPY-BS48PEA

960GBM.2 2280

PCIe4.0 x40,9Boot

PYBBS96PEAPY-BS96PEA

M.2 drive is designed for use as a boot drive with the Endurance Spec. above.

max. 2x per Server; connector located on Motherboard (please see folder "description"). 2x M.2 drives require Intel VROC Upgrade Key Premium(PYBRLVR02).

2x M.2 drives required; in case M.2 drives are used with PDUAL CP300.

Dual M.2

PDUAL CP100, PDUAL CP300 and M.2 drive on Motherboard cannot be mixed

PDUAL CP100, dual M.2 for booting, non hot-plug

CapacityFormfactor

InterfaceCategoryorder code E-partorder code L-part

n/aAIC

PCIeBootFH

PYBDMCP24

n/aAIC

PCIeBootLP

PYBDMCP24L

PY-DMCP24

PDUAL CP100 is a carrier of 2x SSD SATA M.2 drives, which offers RAID1 with the 2x SSD M.2 drives.

PDUAL CP100 is designed for use as a hardware-mirrored (RAID1) boot device for Hypervisor, which cannot be supported by M.2 via the onboard chipset Software RAID.

Supported RAID level : RAID1 only, 2x same type of SSD M.2 drives need to be ordered separately.

Supported M.2 drives : SSD SATA M.2 240GB/480GB/960GB or 240GB for VMware ESXi. (S26361-F5787- E240/L240/E480/L480, PY*MF96YN or S26361-F5816-E240/L240)

max. 1x per Server, requires 2x SSD SATA M.2 drives.

PDUAL CP100, PDUAL CP300 and M.2 drive on Motherboard cannot be mixed

PDUAL CP300, dual M.2 for booting, non hot-plug

available from 2024/02

CapacityFormfactor

InterfaceCategoryorder code E-partorder code L-part

n/aAIC

PCIeBootFH

PYBDMCP35

n/aAIC

PCIeBootLP

PYBDMCP35L

PY-DMCP35

PDUAL CP300 is a carrier of 2x SSD SATA or PCIe M.2 drives, which offers RAID1 with the 2x SSD M.2 drives.

PDUAL CP300 is designed for use as a hardware-mirrored (RAID1) boot device for Hypervisor, which cannot be supported by M.2 via the onboard chipset Software RAID.

Supported RAID levels : RAID1 and 0 (optional), 2x same type of SSD M.2 drives need to be ordered separately.

Supported M.2 drives : SSD SATA M.2 240GB/480GB/960GB or 240GB for VMware ESXi. (S26361-F5787- E240/L240/E480/L480, PY*MF96YN or S26361-F5816-E240/L240) or

SSD PCIe M.2 480GB/960GB. (PY*BS48PEA/PY*BS96PEA)

max. 1x per Server, requires 2x SSD M.2 drives.

cnfgTX2550M7-20231117__SSDPage 27 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

2.5" (SFF) PCIe-SSD

hot plug support : supported with VMD

PCIe-SSD 2.5" P5800X

(SFF) Enterprise with hot plug/hot replace tray

based on Intel P5800X drives

CapacityFormfactor

InterfaceEnduranceDWPDorder code E-partorder code L-part

400GB2.5" (SFF)

PCIe4.0 x4Write Intensive100

PYBBS40PFPY-BS40PF

800GB2.5" (SFF)

PCIe4.0 x4Write Intensive100

PYBBS80PFPY-BS80PF

1.6TB2.5" (SFF)

PCIe4.0 x4Write Intensive100

PYBBS16PFPY-BS16PF

max. 8x (4x per CPU) - depending on base unit & configuration

limitation : can not support VROC so farwill be available in CQ4'23

PCIe-SSD 2.5" Mixed Use

(SFF) Enterprise with hot plug/hot replace tray

based on Kioxia CM7-V drives

CapacityFormfactor

InterfaceEnduranceDWPDorder code E-partorder code L-part

1.6TB2.5" (SFF)

PCIe5.0 x4Mixed Use3

PYBBS16PDBPY-BS16PDB

3.2TB2.5" (SFF)

PCIe5.0 x4Mixed Use3

PYBBS32PDBPY-BS32PDB

6.4TB2.5" (SFF)

PCIe5.0 x4Mixed Use3

PYBBS64PDBPY-BS64PDB

12.8TB2.5" (SFF)

PCIe5.0 x4Mixed Use3

PYBBS12PDBPY-BS12PDB

max. 8x (4x per CPU) - depending on base unit & configuration

EOL, as long as stock available

PCIe-SSD 2.5" Mixed Use

(SFF) Enterprise with hot plug/hot replace tray

based on Kioxia CM6-V drives

CapacityFormfactor

InterfaceEnduranceDWPDorder code E-partorder code L-part

1.6TB2.5" (SFF)

PCIe4.0 x4Mixed Use3

PYBBS16PD6PY-BS16PD6

3.2TB2.5" (SFF)

PCIe4.0 x4Mixed Use3

PYBBS32PD6PY-BS32PD6

6.4TB2.5" (SFF)

PCIe4.0 x4Mixed Use3

PYBBS64PD6PY-BS64PD6

12.8TB2.5" (SFF)

PCIe4.0 x4Mixed Use3

PYBBS12PD6PY-BS12PD6

max. 8x (4x per CPU) - depending on base unit & configuration

limitation : can not support VROC so farwill be available in CQ4'23

PCIe-SSD 2.5" Read Intensive

(SFF) Enterprise with hot plug/hot replace tray

based on Kioxia CM7-R drives

CapacityFormfactor

InterfaceEnduranceDWPDorder code E-partorder code L-part

1.92TB2.5" (SFF)

PCIe5.0 x4Read Intensive1

PYBBS19PEAPY-BS19PEA

3.84TB2.5" (SFF)

PCIe5.0 x4Read Intensive1

PYBBS38PEAPY-BS38PEA

7.68TB2.5" (SFF)

PCIe5.0 x4Read Intensive1

PYBBS76PEAPY-BS76PEA

15.36TB2.5" (SFF)

PCIe5.0 x4Read Intensive1

PYBBS15PEBPY-BS15PEB

max. 8x (4x per CPU) - depending on base unit & configuration

EOL, as long as stock available

PCIe-SSD 2.5" Read Intensive

(SFF) Enterprise with hot plug/hot replace tray

based on Kioxia CM6-R drives

CapacityFormfactor

InterfaceEnduranceDWPDorder code E-partorder code L-part

960GB2.5" (SFF)

PCIe4.0 x4Read Intensive1

PYBBS96PE6PY-BS96PE6

1.92TB2.5" (SFF)

PCIe4.0 x4Read Intensive1

PYBBS19PE6PY-BS19PE6

3.84TB2.5" (SFF)

PCIe4.0 x4Read Intensive1

PYBBS38PE6PY-BS38PE6

7.68TB2.5" (SFF)

PCIe4.0 x4Read Intensive1

PYBBS76PE6PY-BS76PE6

15.36TB2.5" (SFF)

PCIe4.0 x4Read Intensive1

PYBBS15PE6PY-BS15PE6

max. 8x (4x per CPU) - depending on base unit & configuration

M

cnfgTX2550M7-20231117__SSDPage 28 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

M

Chapter 11 - LAN Components

FH PCI card requires FH PCI riser. Please refer to ''Chapter 14 - PCI Riser'.

Broadcom 1GbE BEASE-T for PCIe

PLAN CP BCM5719-4P 4X 1000BASE-T PCIe LP6x

PLAN CP BCM5719-4P 4X 1000BASE-T PCIe FH8x

Broadcom, 1GTx4port

PYBLA284L

PYBLA284

PY-LA284

max. 10 adapters per system

Intel 1GbE BASE-T for PCIe

PLAN CP 2x1Gbit Cu Intel I350-T2 LP *1

6x

Intel, 1GTx2port

S26361-F4610-E202S26361-F4610-L502

PLAN CP 4x1Gbit Cu Intel I350-T4 LP6x

Intel, 1GTx4port

S26361-F4610-E204

S26361-F4610-L504

max. 6 adapters per system

*1 Will be available from 2Q, CY2024

Broadcom 10GbE BEASE-T for PCIe

PLAN EP P210TP 2X 10GBASE-T PCIe LP4x

PLAN EP P210TP 2X 10GBASE-T PCIe FH6x

Broadcom, 10GTx2port

PYBLA3K2L

PYBLA3K2

PY-LA3K2

max. 6x adapters per system (must not exceed this number with P210TP and P210P in total and LP cannnot be put on slot#3, slot#10)

Intel 10GbE BASE-T for PCIe

PLAN EP X710-T2L 2X 10GBASE-T LP6xPYBLA342L

PLAN EP X710-T2L 2X 10GBASE-T FH8x

Intel, 10GTx2port

PYBLA342

PY-LA342

PLAN EP X710-T4L 4X 10GBASE-T LP6xPYBLA344L

PLAN EP X710-T4L 4X 10GBASE-T FH8x

Intel, 10GTx4port

PYBLA344

PY-LA344

max. 10x adapters per system

Broadcom 10GbE for PCIe

Each cage consumes 1x optical SFP+ transceiver per port.

Dual rate 10G/1G support requires 10G/1G Dual Rate SFP+ Optical Transceiver Modules.

All ports on this card can install the same Parts Number of optical module.

PLAN EP P210P 2x10Gb SFP PCIe LP4x

PYBLA3J2L

PLAN EP P210P 2x10Gb SFP PCIe FH6x

Broadcom, 10Gx2port

PYBLA3J2

PY-LA3J2

Optional, 10Gb SFP+ optical transceiver module, select one per cage

SFP+ Optical Transceiver 10G Single Rate SR

2x

Finisar, 10G SR SFP+

S26361-F3986-E3S26361-F3986-L3

SFP+ Optical Transceiver 10G/1G Dual Rate

SR

2x

Intel, 1G/10G SR SFP+

S26361-F3986-E5S26361-F3986-L5

SFP+ Optical Transceiver 10G/1G Dual Rate LR

2x

Intel, 1G/10G LR SFP+

S26361-F3986-E6S26361-F3986-L6

max. 1x per port

max. 6x adapters per system (must not exceed this number with P210TP and P210P in total and LP cannnot be put on slot#3, slot#10)

Intel 10GbE for PCIe

Each cage consumes 1x optical SFP+ transceiver per port.

Dual rate 10G/1G support requires 10G/1G Dual Rate SFP+ Optical Transceiver Modules.

All ports on this card can install the same Parts Number of optical module.

PLAN EP X710-DA2 2x10Gb SFP+ LP6xS26361-F3640-E202

PLAN EP X710-DA2 2x10Gb SFP+ FH8x

Intel, 10Gx2port

S26361-F3640-E2

S26361-F3640-L502

PLAN EP X710-DA4 4x10Gb SFP+ LP6xS26361-F3640-E204

PLAN EP X710-DA4 4x10Gb SFP+ FH8x

Intel, 10Gx4port

S26361-F3640-E4

S26361-F3640-L504

Optional, 10Gb SFP+ optical transceiver module, select one per cage

SFP+ Optical Transceiver 10G Single Rate SR

4x

Finisar, 10G SR SFP+

S26361-F3986-E3S26361-F3986-L3

SFP+ Optical Transceiver 10G/1G Dual Rate

SR

4x

Intel, 1G/10G SR SFP+

S26361-F3986-E5S26361-F3986-L5

SFP+ Optical Transceiver 10G/1G Dual Rate LR

4x

Intel, 1G/10G LR SFP+

S26361-F3986-E6S26361-F3986-L6

max. 1x per port

max. 10x adapters per system

Broadcom 25GbE for PCIe

Each cage consumes 1x optical SFP28.

All ports on this card can install the same Parts Number of optical module.

10G SFP BTO is not available for 25G cards, please select L parts.

PLAN EP P225P 25Gb 2p SFP28 PCIe LP *1

6x

PYBLA3H2L

PLAN EP P225P 25Gb 2p SFP28 PCIe FH *1

8x

Broadcom, 25Gx2port

PYBLA3H2

PY-LA3H2

Optional, 25Gb SFP28 optical transceiver module, select one per cage

SFP28 25G SR E25GSFP28SRX LC

2x

Intel, 25G SR SFP28PYBSFPS56PY-SFPS56

max. 1x per port

Optional, 10Gb SFP+ optical transceiver module, select one per cage

SFP+ Optical Transceiver 10G/1G Dual Rate

SR

2x

Intel, 1G/10G SR SFP+

S26361-F3986-E5S26361-F3986-L5

SFP+ Optical Transceiver 10G/1G Dual Rate LR

2x

Intel, 1G/10G LR SFP+

S26361-F3986-E6S26361-F3986-L6

max. 1x per port

max. 10x adapters per system

*1 Will be available from 1Q, CY2024

cnfgTX2550M7-20231117_NPage 29 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

NVIDIA 25GbE for PCIe

Each cage consumes 1x optical SFP28.

All ports on this card can install the same Parts Number of optical module.

10G SFP BTO is not available for 25G cards, please select L parts.

Ethernet Network Adapters

PLAN EP MCX6-LX 25Gb 2p SFP28 PCIe LP *1

6x

PYBLA402L4

PLAN EP MCX6-LX 25Gb 2p SFP28 PCIe FH *1

8x

NVIDIA, 25Gx2port

PYBLA4024

PY-LA4024

Optional, 25Gb SFP28 optical transceiver module, select one per cage

SFP28 25G SR E25GSFP28SRX LC

2x

Intel, 25G SR SFP28PYBSFPS56PY-SFPS56

SFP28 Optical Transceiver 25G SR MMA2P00-

AS LC

2x

NVIDIA, 25G SR SFP28S26361-F4054-E701S26361-F4054-L701

max. 1x per port

Optional, 10Gb SFP+ optical transceiver module, select one per cage

SFP+ Optical Transceiver 10G/1G Dual Rate

SR

2x

Intel, 1G/10G SR SFP+

S26361-F3986-E5S26361-F3986-L5

SFP+ Optical Transceiver 10G/1G Dual Rate LR

2x

Intel, 1G/10G LR SFP+

S26361-F3986-E6S26361-F3986-L6

max. 1x per port

max. 10x adapters per system

*1 Will be available from 1Q, CY2024

Intel 25GbE for PCIe

Each cage consumes 1x optical SFP28.

All ports on this card can install the same Parts Number of optical module.

10G SFP BTO is not available for 25G cards, please select L parts.

PLAN EP E810-XXVDA2 2X 25G SFP28 LP6x

PLAN EP E810-XXVDA2 2X 25G SFP28 FH8x

Intel, 25Gx2port

PYBLA402L

PYBLA402

PY-LA402

PLAN EP E810-XXVDA4 4X 25G SFP28 LP

6x

Intel, 25Gx4port

PYBLA404L

PY-LA404

Optional, 25Gb SFP28 optical transceiver module, select one per cage

SFP28 25G SR E25GSFP28SRX LC

4x

Intel, 25G SR SFP28

PYBSFPS56PY-SFPS56

max. 1x per port

Optional, 10Gb SFP+ optical transceiver module, select one per cage

SFP+ Optical Transceiver 10G/1G Dual Rate

SR

4x

Intel, 1G/10G SR SFP+

S26361-F3986-E5S26361-F3986-L5

SFP+ Optical Transceiver 10G/1G Dual Rate LR

4x

Intel, 1G/10G LR SFP+

S26361-F3986-E6S26361-F3986-L6

max. 1x per port

max. 10x adapters per system(E810-XXVDA2) / max. 6x adapters per system(E810-XXVDA4)

Broadcom 100GbE for PCIe

Each cage consumes 1x optical QSFP28

All ports on this card can install the same Parts Number of optical module.

PLAN EP P2100G 100Gb 2p QSFP56 PCIe LP *16xBroadcom, 100Gx2portPYBLA442LPY-LA442

PLAN EP P2100G 100Gb 2p QSFP56 PCIe FH *14xBroadcom, 100Gx2portPYBLA442PY-LA442

Optional, 100Gb QSFP28 Optical Transceiver module

QSFP28 100G SR4 E100GQSFP28SRX MPO

2x

Intel, 100G SR4 QSFP28PYBSFPS54PY-SFPS54

QSFP28 100G SR4 MPO 850nm 100m

MMA1B00-C100D

2x

NVIDIA, 100G SR4 QSFP28S26361-F4052-E701S26361-F4052-L701

max. 1x per port

max. 6x adapters per system

*1 Will be available from 1Q, CY2024

Intel 100GbE for PCIe

Each cage consumes 1x optical QSFP28.

The QSFP will not ship on the card because it will interfere with the shipping box.

All ports on this card can install the same Parts Number of optical module.

PLAN EP E810-CQDA2 2X 100G QSFP28 LP6x

Intel, 100Gx2portPYBLA432LPY-LA432

Optional, 100Gb QSFP28 Optical Transceiver module

QSFP28 100G SR4 E100GQSFP28SRX MPO

2x

Intel, 100G SR4 QSFP28PYBSFPS54PY-SFPS54

max. 1x per port

max. 6x adapters per system

NVIDIA 100GbE for PCIe

Each cage consumes 1x optical QSFP28

The QSFP will not ship on the card because it will interfere with the shipping box.

All ports on this card can install the same Parts Number of optical module.

PLAN EP MCX6-DX 2X 100G QSFP28 LP6x

NVIDIA, 100Gx2portPYBLA412LPY-LA412

Optional, 100Gb QSFP28 Optical Transceiver module

QSFP28 100G SR4 MPO 850nm 100m

MMA1B00-C100D

2x

NVIDIA, 100G SR4 QSFP28

S26361-F4052-E701S26361-F4052-L701

max. 1x per port

max. 6x adapters per system

N

Network cables for later upgrade

O

cnfgTX2550M7-20231117_NPage 30 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

Chapter 12 - Fibre Channel Controller

O

FH PCIe card requires FH PCIe riser card. Please refer to ''Chapter 14 - PCI riser card'.

max number of some controllers can vary with base units with 6x card slots

64G Fibre Channel adapters with LC interface for 50µm optical cables (OM4 or OM3)

PFC EP LPe36000 1X 32GFC PCIe v4 LP6x

Broadcom, 64GFCx1port

PFC EP LPe36000 1X 32GFC PCIe FH8x

PFC EP LPe36002 2X 32GFC PCIe v4 LP6x

Broadcom, 64GFCx2port

PFC EP LPe36002 2X 32GFC PCIe v4 FH8x

6x

PFC EP QLE2870 1X 32GFC PCIe v4 LP

Marvell, 64GFCx1port

PFC EP QLE2870 1X 32GFC PCIe v4 FH 8x

PFC EP QLE2872 2X 32GFC PCIe v4 LP 6x

Marvell, 64GFCx2port

PFC EP QLE2872 2X 32GFC PCIe v4 FH 8x

32G Fibre Channel adapters with LC interface for 50µm optical cables (OM4 or OM3)

PFC EP LPe35000 1X 32GFC PCIe v4 LP6x

Broadcom, 32GFCx1port

PFC EP LPe35000 1X 32GFC PCIe v4 FH8x

PFC EP LPe35002 2X 32GFC PCIe v4 LP6x

Broadcom, 32GFCx2port

PFC EP LPe35002 2X 32GFC PCIe v4 FH8x

PFC EP QLE2770 1X 32GFC PCIe v4 LP6x

Marvell, 32GFCx1port

PFC EP QLE2770 1X 32GFC PCIe v4 FH8x

PFC EP QLE2772 2X 32GFC PCIe v4 LP6x

Marvell, 32GFCx2port

PFC EP QLE2772 2X 32GFC PCIe v4 FH 8x

16G Fibre Channel adapters with LC interface for 50µm optical cables (OM4 or OM3)

PFC EP LPe31000 1x 16Gb LP6x

Broadcom, 16GFCx1port

PFC EP LPe31000 1x 16Gb FH8x

PFC EP LPe31002 2x 16Gb LP6x

Broadcom, 16GFCx2port

PFC EP LPe31002 2x 16Gb FH8x

PFC EP QLE2690 1x 16Gb LP6x

Marvell, 16GFCx1port

PFC EP QLE2690 1x 16Gb FH8x

PFC EP QLE2692 2x 16Gb LP6x

Marvell, 16GFCx2port

PFC EP QLE2692 2x 16Gb FH8x

max. 10 adapters per system

PYBFC441L

PYBFC441

PYBFC442L

PYBFC442

PYBFC431L

PYBFC431

PYBFC432L

PYBFC432

PYBFC421L

PYBFC421

PYBFC422L

PYBFC422

PYBFC411L

PYBFC411

PYBFC412L

PYBFC412

S26361-F5596-E201

S26361-F5596-E1

S26361-F5596-E202

S26361-F5596-E2

S26361-F5580-E201

S26361-F5580-E1

S26361-F5580-E202

S26361-F5580-E2

PY-FC441

PY-FC442

PY-FC431

PY-FC432

PY-FC421

PY-FC422

PY-FC411

PY-FC412

S26361-F5596-L501

S26361-F5596-L502

S26361-F5580-L501

S26361-F5580-L502

Chapter 13 - Infiniband Controllers

Infinibandand Omni path controller will not be released.

P

cnfgTX2550M7-20231117__IBPage 31 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

Chapter 14 - PCI riser card

PCI riser card configuration

Standard Model only(PYT2557TAN/PYT2557TBN/PYT2557TCN

/PYT2557R3N/PYT2557R2N/PYT2557RAN)

6x PCIe slots are on board, with optional PCIe riser card up to 10x PCIe slots are available.

You can choose between 6 different PCI riser card (Options a – f), depending on the selected PCIe card or GPGPU.

Please refer to the tables below for more details and for the installation rules.

Required 'Configuration Thermal Design 30°C(CTD30)[PYBETA1]'

P

Full height PCIe card

A100, A30, A16, L40

or x16 PCIe card

is selected

Details of each PCIe riser card option (a – f) are described on the following pages

T400 4GB, A2, L4,

RTX A6000, RTX

A4500, RTX 6000

or x16 PCIe card

is selected

T400 4GB

or x8 PCIe card

is selected

Option c)

Full height 4slot PCIe riser card

(x8 Gen4)

A100, A30, A16, L40,

,H100

or x16 PCIe card

is selected

T400 4GB, A2, L4,

RTX A6000, RTX

A4500, RTX 6000

or x16 PCIe card

is selected

T400 4GB

or x8 PCIe card

is selected

Option f)

Full height 4slot PCIe riser card

(x8 Gen5)

with retimer

Option a)

Full height 2slot PCIe riser card

(x16 Gen4)

with PCIe support bracket

Option d)

Full height 2slot PCIe riser card

(x16 Gen5)

with PCIe support bracket

with retimer

Option b)

Full height 2slot PCIe riser card

(x16 Gen4)

without PCIe support bracket

Option e)

Full height 2slot PCIe riser card

(x16 Gen5)

without PCIe support bracket

with retimer

Q

Possible configurations with each PCIe riser card option

*Support brackets are required for the cooling of passively cooled FH GPUs.

cnfgTX2550M7-20231117_I_riser_cardPage 32 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

Option a) Full height 2slot PCIe riser card (x16 Gen4) with PCIe support bracket

If the below 2 options are selected, 6x PCIe slots (LP/ x16) change to 2x PCIe slots (LP/ x16) + 4x PCIe slots (FH/ x16).

PCIe cards and double width GPGPUs can be supported on 4x PCIe slots (FH/ x16).

One full height GPGPU can be installed on 1x PCIe slot (FH/ x16).

Support brackets are required for the cooling of passively cooled FH GPUs.“

A100, A30, A16, L40 and / or FH PCIe card is selected

Full height 2slot PCIe riser card right (CPU 1) with PCIe support bracket

PYBPRE638 / PY-PRE638

x16 Gen4 PCIe riser card

Note:

With this card, 3x PCIe slots (LP/ x16) change to 1x PCIe slots (LP/ x16) + 2x PCIe slots (FH/ x16).

Please refer to ‘Chapter 5 – Graphics cards’ for more details about the supported GPGPUs’.

Please refer to chapter ‘Thermal’ for more details about limitations’.

Full height 2slot PCIe riser card left (CPU 2) with PCIe support bracket

PYBPRE639 / PY-PRE639

x16 Gen4 PCIe riser card

Note:

2nd CPU is needed.

With this card, 3x PCIe slots (LP/ x16) change to 1x PCIe slots (LP/ x16) + 2x PCIe slots (FH/ x16).

Please refer to ‘Chapter 5 – Graphics cards’ for more details about the supported GPGPUs'.

Option b) Full height 2slot PCIe riser cards (x16 Gen4) without PCIe support bracket

If the below 2 options are selected, 6x PCIe slots (LP/ x16) change to 2x PCIe slots (LP/ x16) + 4x PCIe slots (FH/ x16).

PCIe cards and double width GPGPUs can be supported on 4x PCIe slots (FH/ x16).

One full height GPGPU can be installed on 1x PCIe slot (FH/ x16).

T400 4GB, A2, L4, RTX A6000, RTX A4500, RTX 6000 and / or FH PCIe card is selected

Full height 2slot PCIe riser card right (CPU 1) without PCIe support bracket

PYBPRE641 / PY-PRE641

x16 Gen4 PCIe riser card

Note:

With this card, 3x PCIe slots (LP/ x16) change to 1x PCIe slots (LP/ x16) + 2x PCIe slots (FH/ x16).

Please refer to ‘Chapter 5 – Graphics cards’ for more details about the supported GPGPUs’.

Please refer to chapter ‘Thermal’ for more details about limitations’.

Full height 2slot PCIe riser card left (CPU 2) without PCIe support bracket

PYBPRE642 / PY-PRE642

x16 Gen4 PCI Riser

Note:

2nd CPU is needed.

With this card, 3x PCIe slots (LP/ x16) change to 1x PCIe slots (LP/ x16) + 2x PCIe slots (FH/ x16).

Please refer to ‘Chapter 5 – Graphics cards’ for more details about the supported GPGPUs'.

Option c) Full height 4slot PCIe riser card (x8 Gen4)

If the below 2 options are selected, 6x PCIe slots (LP/ x16) change to 2x PCIe slots (LP/ x16) + 8x PCIe slots (FH/ x8).

GPGPU(Double height) cannot be supported.

T400 4GB and / or FH PCIe card is selected

Full height 4slot PCIe riser card right (CPU1)

PYBPRE848 / PY-PRE848

x8 Gen4 PCIe riser card

Note:

With this card, 3x PCIe slots (LP/ x16) change to 1x PCIe slots (LP/ x16) + 4x PCIe slots (FH/ x8).

Please refer to ‘Chapter 5 – Graphics cards’ for more details about the supported GPGPUs’.

Please refer to chapter ‘Thermal’ for more details about limitations’.

Full height 4slot PCIe riser card left (CPU2)

PYBPRE849 /PY-PRE849

x8 Gen4 PCI Riser

Note:

2nd CPU is needed

With this card, 3x PCIe slots (LP/ x16) change to 1x PCIe slots (LP/ x16) + 4x PCIe slots (FH/ x8).

Please refer to ‘Chapter 5 – Graphics cards’ for more details about the supported GPGPUs’.

cnfgTX2550M7-20231117_I_riser_cardPage 33 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

Option d) Full height 2slot PCIe riser card (x16 Gen5) with PCIe support bracket with Retimer

If the below 2 options are selected, 6x PCIe slots (LP/ x16) change to 2x PCIe slots (LP/ x16) + 4x PCIe slots (FH/ x16).

PCIe cards and double width GPGPUs can be supported on 4x PCIe slots (FH/ x16).

One full height GPGPU can be installed on 1x PCIe slot (FH/ x16).

Support brackets are required for the cooling of passively cooled FH GPUs.“

A100, A30, A16, L40, H100 and / or FH PCIe card is selected

Full height 2slot PCIe riser card right (CPU 1) with PCIe support bracket with Retimer

PYBPRE643 / PY-PRE643

x16 Gen5 PCI riser card

Note:

With this card, 3x PCIe slots (LP/ x16) change to 1x PCIe slots (LP/ x16) + 2x PCIe slots (FH/ x16).

Please refer to ‘Chapter 5 – Graphics cards’ for more details about the supported GPGPUs’.

Please refer to chapter ‘Thermal’ for more details about limitations’.

Full height 2slot PCIe riser card left (CPU 2) with PCIe support bracket with Retimer

PYBPRE644 / PY-PRE644

x16 Gen5 PCI riser card

Note:

2nd CPU is needed.

With this card, 3x PCIe slots (LP/ x16) change to 1x PCIe slots (LP/ x16) + 2x PCIe slots (FH/ x16).

Please refer to ‘Chapter 5 – Graphics cards’ for more details about the supported GPGPUs'.

Option e) Full height 2slot PCIe riser card (x16 Gen5) without PCIe support bracket with Retimer

If the below 2 options are selected, 6x PCIe slots (LP/ x16) change to 2x PCIe slots (LP/ x16) + 4x PCIe slots (FH/ x16).

PCIe cards and double width GPGPUs can be supported on 4x PCIe slots (FH/ x16).

One full height GPGPU can be installed on 1x PCIe slot (FH/ x16).

T400 4GB, A2, L4, RTX A6000, RTX A4500, RTX 6000 and / or FH PCIe card is selected

Full height 2slot PCIe riser card right (CPU 1) without PCIe support bracket with Retimer

PYBPRE645 / PY-PRE645

x16 Gen5 PCI riser card

Note:

With this card, 3x PCIe slots (LP/ x16) change to 1x PCIe slots (LP/ x16) + 2x PCIe slots (FH/ x16).

Please refer to ‘Chapter 5 – Graphics cards’ for more details about the supported GPGPUs’.

Please refer to chapter ‘Thermal’ for more details about limitations’.

Full height 2slot PCIe riser card left (CPU 2) without PCIe support bracket with Retimer

PYBPRE646 / PY-PRE646

x16 Gen5 PCI riser card

Note:

2nd CPU is needed.

With this card, 3x PCIe slots (LP/ x16) change to 1x PCIe slots (LP/ x16) + 2x PCIe slots (FH/ x16).

Please refer to ‘Chapter 5 – Graphics cards’ for more details about the supported GPGPUs'.

Option f) Full height 4slot PCIe riser card (x8 Gen5) with Retimer

If the below 2 options are selected, 6x PCIe slots (LP/ x16) change to 2x PCIe slots (LP/ x16) + 8x PCIe slots (FH/ x8).

GPGPU(Double height) cannot be supported.

T400 4GB and / or FH PCIe card is selected

Full height 4slot PCIe riser card right (CPU1) with Retimer

PYBPRE851 / PY-PRE851

x8 Gen5 PCI riser card

Note:

With this card, 3x PCIe slots (LP/ x16) change to 1x PCIe slots (LP/ x16) + 4x PCIe slots (FH/ x8).

Please refer to ‘Chapter 5 – Graphics cards’ for more details about the supported GPGPUs’.

Please refer to chapter ‘Thermal’ for more details about limitations’.

Full height 4slot PCIe riser card left (CPU2) with Retimer

PYBPRE852 / PY-PRE852

x8 Gen5 PCI riser card

Note:

2nd CPU is needed

With this card, 3x PCIe slots (LP/ x16) change to 1x PCIe slots (LP/ x16) + 4x PCIe slots (FH/ x8).

Please refer to ‘Chapter 5 – Graphics cards’ for more details about the supported GPGPUs’.

cnfgTX2550M7-20231117_I_riser_cardPage 34 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

Chapter 15 - Power supply unit, power cable, certifications, region kits

R

Power supply unit

modular redundant Power Supply

2nd PSU for redundancy basically.

occupies hot plug PSU slot, min. 1 / max. 2x per system. The different PSU mixed configuration does NOT support.

input nominal voltage (AC): 100V-240V, max: 90V-264V; input dropout 10ms/100% load, 47Hz-63Hz

500W platinum PSU

94% eff. Connector type: C13, APAC/JAPAN region only

PYBPU501PY-PU501

500W titanium PSU

96% eff. Connector type: C13, nom. 220-240V, max. 180-264V

PYBPU503PY-PU503

900W platinum PSU

94% eff. Connector type: C13, APAC/JAPAN region only

PYBPU902PY-PU902

900W titanium PSU

96% eff. nom. 220-240V, max. 180-264V

PYBPU901PY-PU901

1600W platinum PSU

94% eff. Connector type: C13, APAC/JAPAN region only

PYBPU163PY-PU163

1600W titanium PSU

96% eff. Connector type: C13, nom. 220-240V, max. 180-264V

PYBPU165PY-PU165

2200W platinum PSU

94% eff. Connector type: C19 200~240V only, APAC/JAPAN region only

PYBPU221PY-PU221

2400W Titanium PSU

96% eff. Connector type: C19, nom. 220-240V, max. 180-264V

PYBPU243PY-PU243

Dummy module instead PSU

Dummy module for closing the 2nd PSU hole, in case only 1 PSU is equipped, max. 1x per systemPYBDMP06-

If Power consumption error occureson 2400W PSU, 'No Redundant' can be selected

PYBVS002

No Power redundant option

If this option is selected, the system may shutdown at the worst case

Note: 2x 1600W or 2x 2200W or 2x 2400W are mandatory.

in one PSU failure. Not allow activity exchange for PSU even if

If Power budget isn't enough even if 2400W PSU is used, it can be used.

two PSU are selected.

max. 1x per system

Power cord option for Tower Server, 1x per PSU

Cable powercord (USA) 15A, 1.8m, black, NEMA 5-15 connector 498G -> C13 (plug), 15A, , rack or wall

T26139-Y1741-E90T26139-Y1741-L90

Cable powercord (Taiwan), 1.8m, rack or wall

T26139-Y1757-E10T26139-Y1757-L10

Cable powercord (D, A, B, F, NL, FIN, N, S, E, P, RUS, TR), 1.8m, grey

T26139-Y1740-E10T26139-Y1740-L10

Cable powercord (China), 1.8m, grey

T26139-Y1743-E10-

Cable powercord (China), 1.8m, black

-T26139-Y1751-L10

Cable powercord (UK, IR), 1.8m, grey

T26139-Y1744-E10T26139-Y1744-L10

Cable powercord (I), 1.8m, grey

T26139-Y1745-E10T26139-Y1745-L10

Cable powercord (DK), 1.8m, grey

T26139-Y1746-E10T26139-Y1746-L10

Cable powercord (ISR), 2.5m, black

T26139-Y1747-E18T26139-Y1747-L18

2200w or more

Power cord 16A IEC320 C19->CEE 7/7, 2.5m for 2200W/2400W PSU

S26361-F3151-L100

Power cord 16A IEC320 C19->C20, 3.5m for 2200W/2400W PSU

S26361-F3151-E300S26361-F3151-L300

Power cord IEC320 C19 -> US NEMA L6-20p, 4m for 2200W/2400W PSU

S26361-F3151-E500S26361-F3151-L500

common

no power cord

T26139-Y3850-E10

Power cord option for Rack Server, 1x per PSU

Cable powercord rack, 1.8m, black, IEC 320 C14 -> C13 (10A plug)

T26139-Y1968-E180T26139-Y1968-L180

Cable powercord rack, 2.5m, black, IEC 320 C14 -> C13 (10A plug)

T26139-Y1968-E250T26139-Y1968-L250

Cable powercord rack, 4m, black, IEC 320 C14 -> C13 (10A plug)

T26139-Y1968-E100T26139-Y1968-L10

Cable powercord (USA) 15A, 1.8m, black, NEMA 5-15 connector 498G -> C13 (plug), 15A, , rack or wall

T26139-Y1741-E90T26139-Y1741-L90

Cable powercord (Taiwan), 1.8m, rack or wall

T26139-Y1757-E10T26139-Y1757-L10

Cable powercord (D, A, B, F, NL, FIN, N, S, E, P, RUS, TR), 1.8m, grey

T26139-Y1740-E10T26139-Y1740-L10

Cable powercord (China), 1.8m, grey

T26139-Y1743-E10-

Cable powercord (China), 1.8m, black

-T26139-Y1751-L10

Cable powercord (UK, IR), 1.8m, grey

T26139-Y1744-E10T26139-Y1744-L10

Cable powercord (I), 1.8m, grey

T26139-Y1745-E10T26139-Y1745-L10

Cable powercord (DK), 1.8m, grey

T26139-Y1746-E10T26139-Y1746-L10

Cable powercord (ISR), 2.5m, black

T26139-Y1747-E18T26139-Y1747-L18

2200w or more

Power cord 16A IEC320 C19->CEE 7/7, 2.5m for 2200W/2400W PSU

S26361-F3151-L100

Power cord 16A IEC320 C19->C20, 3.5m for 2200W/2400W PSU

S26361-F3151-E300S26361-F3151-L300

Power cord IEC320 C19 -> US NEMA L6-20p, 4m for 2200W/2400W PSU

S26361-F3151-E500S26361-F3151-L500

common

no power cord

T26139-Y3850-E10

One region kit mandatory

S26361-F1452-E100S26361-F1452-E101S26361-F1452-E130S26361-F1452-E140

REGION KIT APAC/EMEARegion Kit China for CCCREGION KIT AmericaREGION KIT Europe

For Shipments to Asia pacific, Contains warranty sheet and For Shipments to America

America, EMEA regionssafety instructions for China, regions

need to be included always into

the order from China country

1x per system1x per system1x per system1x per system

S26361-F3301-E120

Certification for China, (CCC)

Certification for China, (CCC), Reduced component

selection possible, only with no power cord option

1x per system

S

cnfgTX2550M7-20231117_UPage 35 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

Chapter 16 - Accessories

S

USB Mouse:

Mouse M520 Black

n/aS26381-K467-L100

Mouse M520 Greyn/a

S26381-K467-L101

Mouse M530 Blackn/aS26381-K468-L100

Mouse M530 Greyn/aS26381-K468-L101

USB Keyboards for Tower Servers for following countries:

Country versionFUJITSU Keyboard KB521 USB (grey)

US/ int 105 keys (UK keyboard + US int. Layout)S26381-K521-L102

Czech/SlovakS26381-K521-L104

US 104 keys (US keyboard + US layout)S26381-K521-L110

GermanyS26381-K521-L120

Germany / IntS26381-K521-L122

FranceS26381-K521-L140

Sweden / FinlandS26381-K521-L154

United KingdomS26381-K521-L165

SwitzerlandS26381-K521-L170

SpainS26381-K521-L180

ItalyS26381-K521-L185

USB Optical Disc Drive

External Ultra Slim Portable DVD Writer (Hitachi-LG)

S26341-F103-L142

T

cnfgTX2550M7-20231117_B devicesPage 36 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

Chapter 17 - Energy Star

T

will be expired after 2024-1-11will be expired after 2024-1-11will be effective after 2024-1-12will be effective after 2024-1-12

S26361-F3301-E551S26361-F3301-E552PYBES26PYBES27

TX2550 Mx E-Star Fam1TX2550 Mx E-Star Fam2TX2550 Mx E-Star Fam1TX2550 Mx E-Star Fam2

Limits configuration in accordance Limits configuration in accordance Limits configuration in accordance Limits configuration in accordance

with Energy Star requirements for systems with 1 CPUwith Energy Star requirements for systems with 2 CPUwith Energy Star requirements for systems with 1 CPUwith Energy Star requirements for systems with 2 CPU

max. 1x per systemmax. 1x per systemmax. 1x per systemmax. 1x per system

1 CPU Variant1 CPU Variant

notallowed are:

limitations for E-Star Fam1certification

2 CPU Variant

notallowed are:

limitations for E-Star Fam2certification

notallowed are:

limitations for E-Star Fam1certification

2 CPU Variant

notallowed are:

limitations for E-Star Fam2certification

-2 CPU configuration

-1 CPU configuration

-2 CPU configuration

-1 CPU configuration

-CPU Xeon Bronze 3408U

-CPU Xeon Bronze 3408U

-CPU Xeon Bronze 3408

-CPU Xeon Silver 4410Y

-CPU Xeon Silver 4410Y

-CPU Xeon Silver 4416+

-CPU Xeon Silver 4416+

-CPU Xeon Gold 5415+

-CPU Xeon Gold 5415+

-CPU Xeon Gold 6426Y

-CPU Xeon Gold 6426Y

-CPU Xeon Gold 6434

-CPU Xeon Gold 6434

-CPU Xeon platinum 8444H

-CPU Xeon platinum 8444H

-CPU Xeon Gold 5416S

-CPU Xeon Gold 5416S

-CPU Xeon Silver 4410T

-CPU Xeon Silver 4410T

-900W platinum PSU

-900W platinum PSU

-1600W platinum PSU

-1600W platinum PSU

-2200W platinum PSU

-2200W platinum PSU

ENERGY STAR-configurations with one CPU will be labeled:

PRIMERGY TX2550 M7 E-Star Fam1

ENERGY STAR-configurations with two CPU will be labeled:

PRIMERGY TX2550 M7 E-Star Fam2

non ENERGY STAR-configurationen will be labeled:

PRIMERGY TX2550 M7

U

cnfgTX2550M7-20231117_ergy StarPage 37 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

Chapter 18 - others (ErP Lot 9 restriction)

U

*Region kit Europe must be orderd for

shipment toship in EU and EFTA

Region Kits, 1x per System

Region Kit APAC/EMEA/India,

Contains warranty sheet and safety instructions

for APAC, EMEA and India

Region Kit America,

Contains warranty sheet, registration hints and

safety instructions for America

S26361-F1452-E100

Region Kits, 1x per System

Region Kit Europe*,

Contains warranty sheet and safety instructions

in German, English, French, Spanish, Italian,

Polish, Russian and Welsh language

S26361-F1452-E140

S26361-F1452-E130

Restriction for ErP Lot 9 directive,

Not allowed: (For all base unit)

- 500W platinum PSU

- 900W platinum PSU

- 1600W platinum PSU

- 2200W platinum PSU

need to select one of PYBETL17 or PYBETL18

ErP Lot9 Restriction for 16GB DIMM, 1x per System

For 2.5" base unit only

2.5" base unit: PYT2557T2N, PYT2557TBN, PYT2557TCN, PYT2557R2N,

PYT2557RAN

Erp Lot9 configuration 1

PYBETL17

ErP Lot9 Restriction for >=32GB DIMM, 1x per System

For all 3.5", 2.5" base unit

3.5" base unti: PYT2557T3N, PYT2557TAN, PYT2557R3N

2.5" base unit: PYT2557T2N, PYT2557TBN, PYT2557TCN, PYT2557R2N,

PYT2557RAN

ErP Lot 9 configuration 2

PYBETL18

Restriction for ErP Lot9 directive,

* this option is NOT avaialble for 3.5" base unit.

(For PYT2557T2N, PYT2557TBN, PYT2557TCN, PYT2557R2N,

PYT2557RAN)

Not allowed:

-CPU: Bronze 3408U (PYBCP65XR)

-NVIDIAT400 (PYBVG4T2L)

-NVMe SSD (PYBBA24PJ, PYBBA24PK, PYBCBE024,

PYBCBE025)

Max qty of 1G LAN card restricted to max. 2

1G LAN: S26361-F4610-E204, PYBLA284L, PYBLA284

Restriction for ErP Lot9 directive,

(For PYT2557T3N, PYT2557TAN, PYT2557R3N,

PYT2557T2N, PYT2557TBN, PYT2557TCN, PYT2557R2N,

PYT2557RAN)

Not allowed:

-CPU: Bronze 3408U (PYBCP65XR)

-DIMM: 16GB DIMM (PYBME16SL)

V

cnfgTX2550M7-20231117_P Lot9Page 38 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

Chapter 19 - others

V

PYBRMC44

PY-RMC44

iRMC advanced pack

integrated remote Management controller activation key for graphical

console redirection and remote media redirection

max. 1x per system

PYBLCM14

embedded Lifecycle Management (eLCM)Loose delivery

Server Online UpdateeLCM Activation Pack

OS driver Update(Node Locked License)

Hardware firmware updatePY-LCM14

Server Offline Updateoptions contains:

Hardware update via Update Manager Express- Paper with TAN for Licensekey

PrimeCollect

Autonomous creation of Primecollect archives

Custom Image (Jukebox function)

Automatic and manual download of CD and DVD Images

Automatic and manual start of CD and DVD Images

max. 1x per system

PYBSSS3

iRMC standard/legacy Option

When this product is orderd, following iRMC default setting is changed.

Unique default password: No. The fixed password is printed on ID tag.

SSH: Enabled

USB Host LAN : Enabled

Force to change default pwd to use Redfish/RESTful/other interfaces: No

max. 1x per system

PY TX2550 M7 Tower 4x3.5' basic and PY

Advanced Thermal Designis not available with LTO drives.

TX2550 M7 Tower 8x2.5' basic do not support

ATD options! For the detail, refer to the 'Therma

chapter'.

S26361-F3776-E440S26361-F3776-E445

Cool-safe ® Advanced Thermal design 40°CCool-safe ® Advanced Thermal design 45°C

enables the PRIMERGY Server to cope with enables the PRIMERGY Server to cope with temperatures from

temperatures from 5-40° in operating mode due to 5-45° in operating mode due to extended Fan settings

extended Fan settings

this setting can be activated ex factory onlythis setting can be activated ex factory only

max. 1x per systemmax. 1x per system

PYBETA1

Configuration Thermal Design 30°C(CTD30)

Sets the PRIMERGY server to support temperatures of up to

30 ° C in operating mode for the configuration with thermal

restriction.

Refer to Chapter15-Thermal Rule

this setting can be activated ex factory only

max. 1x per system

cnfgTX2550M7-20231117_hersPage 39 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

PYBCOM08

PY-COM08

Serial Port Option

RS-232-C for a RS-232-C Serial Port Interface

does NOT occupy PCI slot

max. 1x per system

PYBVAP08

PY-VAP08

Front VGA Option

VGA Interface

does NOT occupy PCI slot

max. 1x per system

will be EOL in CQ2'24

PYBTPM14

PY-TPM14

TPM 2.0 Module SPI

required for Microsoft Windows Server 2022 (host OS)

max. 1x per system

will be available in CQ1'24

PYBTPM20

PY-TPM20

TPM 2.0 Module V2

required for Microsoft Windows Server 2022 (host OS)

max. 1x per system

PYBNTPM

No TPM for WINSVR

Either PYBTPM14 or PYBNTPM is required

in ordering Windows Server 2022 OEM

max. 1x per system

When Windows Server 2022 is used as a host OS, PYBTPM14, PY-TPM14, PYBTPM20 or PY-TPM20 is

required. This requirement, however, can be waived if the end customer expresses their desire to

configure the server system without a TPM. In that case, No TPM for WINSVR can be selected.

When Windows Server 2022 is used as a guest OS, TPMs are not necessary.

OS support matrix:

PYBTPM14PYBTPM20

Operating system for host OSPY-TPM14PY-TPM20

Windows Server 2022requiredrequired

Windows Server 2019supportedsupported

Windows Server 2016supported-

Red Hat Enterprise Linux 8supportedsupported

Red Hat Enterprise Linux 7supportedsupported

SUSE Linux Enterprise Server 15--

VMware ESXi 7.0supportedsupported

VMware ESXi 6.7supported-

PYBTPM14/PY-TPM14 are currently available when will be EOL in CQ2'24

PYBTPM20/PY-TPM20 will be an alternative in CQ1'24

because new TPM supports mandatory to fit to new Windows requirement

New TPM are backward compatible with former TPMs.

PY-FOP17

4U Rack Front Bezel

Front Bezel on front Base

max. 1x per system

Your server is ready

cnfgTX2550M7-20231117_hersPage 40 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

Chapter 20 - Thermal Rule

Basic Model(PYT2557T3N / PYT2557T2N) ATD40 and ATD45 can't be supported.

Basic model

CPUMemoryDrive bayOption cardAmbient

4x3.5"8x3.5"8x2.5"LP PCIe / Nvidia T400FH PCIe / GPGPU on PCI RiserTemp.

No limitation

No limitationNo limitationLevel1-6 / Nvidia T400Not support

35C

Basic model for PCIe Level7

CPUMemoryDrive bayOption cardAmbient

4x3.5"8x3.5"8x2.5"LP PCIe / Nvidia T400FH PCIe / GPGPU on PCI RiserTemp.

CPU A

16GB - 64GB DDR5

on board SATA or RAID

CPU B

controller on slot1.

Level1-7 / Nvidia T400Not support

30C

CPU C

CPU D

Not supportNot support

* Need to select Configuration Thermal Design 30℃(PYBETA1)

Standard Model(PYT2557TAN/PYT2557TBN/PYT2557TCN/PYT2557R3N/PYT2557R2N/PYT2557RAN)

Standard model for ATD45

CPUMemoryDrive bayOption cardAmbient

LP PCIe / Nvidia T400FH PCIe / GPGPU on PCI RiserTemp.

No limitation

No limitationNo limitationLevel1-4 / Nvidia T400Not support

45C

* SSD support only. HDD can't be supported. LTO can't be supported.

Standard model for ATD40

CPUMemoryDrive bayOption cardAmbient

LP PCIe / Nvidia T400FH PCIe / GPGPU on PCI RiserTemp.

No limitation

No limitationNo limitationLevel1-5 / Nvidia T400Not support

40C

* SSD support only. HDD can't be supported. LTO can't be supported.

Standard model

CPUMemoryDrive bayOption cardAmbient

LP PCIe / Nvidia T400GPGPU on PCI Riser / FH PCIeTemp.

No limitation

No limitationNo limitationLevel1-6 / Nvidia T400Not support

35C

Standard model for FH PCIe/GPGPU on PCI Riser

CPUMemoryDrive bayOption cardAmbient

LP PCIe / Nvidia T400GPGPU on PCI Riser / FH PCIeTemp.

No limitation No limitation

No limitation

Level1-6 / Nvidia T400

GPGPU Group A / Level1-6

SSD only

GPGPU Group B / Level1-6

30C

* Need to select Configuration Thermal Design 30℃(PYBETA1)

Standard model for PCIe Level7

CPUMemoryDrive bayOption cardAmbient

8x3.5"12x3.5"8x2.5"LP PCIe / Nvidia T400FH PCIe / GPGPU on PCI RiserTemp.

CPU A

16GB - 64GB DDR5

on board SATA or RAID

CPU B

controller on slot1.

Level1-7 / Nvidia T400Not support

30C

CPU C

CPU D

Not supportNot support

* Need to select Configuration Thermal Design 30℃(PYBETA1)

cnfgTX2550M7-20231117_ermalPage 41 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

Option card: PCIe Level for Thermal condition

Card

RAID/SASPDUAL CP100

PDUAL CP300

PSAS CP600e FH / LP

PSAS CP600i LP

PSAS CP600i LP for LTO

PRAID CP600i LP

PRAID EP640i LP

PRAID EP680i LP / NVMe FH / LP

PRAID EP680e RAID Contr. FH/LP

PSAS CP2100-8i LP

PSAS CP2200-16i LP / NVMe FH / LP

PSAS CP 2200-16i LP for LTO

PRAID EP3252-8i LP

PRAID EP3254-8i LP

PRAID EP3258-16i LP / NVMe FH / LP

PRAID EP740i LP / NVMe FH / LP

PFC EP LPe31000 1x 16Gb FH / LP

PFC EP LPe31002 2x 16Gb FH / LP

PFC EP LPe35000 1X 32GFC PCIe v4 / LP

PFC EP LPe35002 2X 32GFC PCIe v4 / LP

PFC EP LPe36000 1X 32GFC PCIe v4 / LP

PFC EP LPe36002 2X 32GFC PCIe v4 / LP

PFC EP QLE2690 1x 16Gb FH / LP

PFC EP QLE2692 2x 16Gb FH / LP

PFC EP QLE2770 1X 32GFC PCIe v4 / LP

PFC EP QLE2772 2X 32GFC PCIe v4 / LP

PFC EP QLE2870 1X 32GFC PCIe v4 / LP

PFC EP QLE2872 2X 32GFC PCIe v4 / LP

PLAN CP 4x1Gbit Cu Intel I350-T4 LP

PLAN EP E810-CQDA2 2X 100G QSFP28 LP

PLAN EP E810-XXVDA2 2X 25G SFP28 FH / LP

PLAN EP E810-XXVDA4 4X 25G SFP28 LP

PLAN EP MCX6-DX 100Gb 2p QSFP28 LP

PLAN EP X710-DA2 2x10Gb SFP+ FH / LP

PLAN EP X710-DA4 4x10Gb SFP+ FH / LP

PLAN EP X710-T2L 2X 10GBASE-T FH / LP

PLAN EP X710-T4L 4X 10GBASE-T FH / LP

PLAN CP BCM5719-4P 4X 1000BASE-T PCIe FH / LP

PLAN EP P210P 2x10Gb SFP FH / LP

PLAN EP P210TP 2X 10GBASE-T PCIe FH / LP

PLAN EP MCX6-LX 25Gb 2p SFP28 PCIe FH / LP

PLAN EP P225P 25Gb 2p SFP28 PCIe FH / LP

PLAN EP P2100G 100Gb 2p QSFP56 PCIe LP

Product Number

PYBVG4A8

PYBVG4L1

PYBVG4A4

PYBVG4A5

PYBVG4A1

PYBVG4L2

PYBGP4A10

PYBVG4A7

PYBGP4H11

PYBVG4A2

PYBVG4L3

Product Number

FH

PYBDMCP24

PYBDMCP35

PYBSC4FAE

- / PYBSR4C62

PYBSR4C6E

- / PYBSC4MA2

FC

LAN

- / PYBSR4MA4

(TBD)

S26361-F5596-E1

S26361-F5596-E2

PYBFC421

PYBFC422

PYBFC441

PYBFC442

S26361-F5580-E1

S26361-F5580-E2

PYBFC411

PYBFC412

PYBFC431

PYBFC432

-

PYBLA432

PYBLA402

PYBLA404

PYBLA412

S26361-F3640-E2

S26361-F3640-E4

PYBLA342

PYBLA344

PYBLA284

PYBLA3J2

PYBLA3K2

PYBLA4024

PYBLA3H2

PYBLA442

LP

PYBDMCP24L

PYBDMCP35L

PYBSC4FAEL

PYBSC4FAL

PYBSC4FA2L

PYBSR4FAL

PYBSR4C63L

PYBSR4C6L / PYBSR4C62L

PYBSR4C6EL

PYBSC3MA2L

PYBSC4MA1L / PYBSC4MA2L

PYBSC4MA3L

PYBSR4MA1L

PYBSR4MA2L

PYBSR4MA3L / PYBSR4MA4L

(TBD)

S26361-F5596-E201

S26361-F5596-E202

PYBFC421L

PYBFC422L

PYBFC441L

PYBFC442L

S26361-F5580-E201

S26361-F5580-E202

PYBFC411L

PYBFC412L

PYBFC431L

PYBFC432L

S26361-F4610-E204

PYBLA432L

PYBLA402L

PYBLA404L

PYBLA412L

S26361-F3640-E202

S26361-F3640-E204

PYBLA342L

PYBLA344L

PYBLA284L

PYBLA3J2L

PYBLA3K2L

PYBLA402L4

PYBLA3H2L

PYBLA442L

PCIe Level

Level4

Level5

Level3

Level3

Level3

Level3

Level3

Level3

Level3

Level3

Level4

Level4

Level4

Level4

Level4

Level4

Level3

Level3

Level4

Level4

Level4

Level4

Level3

Level3

Level4

Level4

Level4

Level4

Level1

Level7

Level5

Level7

Level7

Level1

Level3

Level2

Level3

Level1

Level3

Level5

Level5

Level3

Level5

Option card: GPGPU Group

GroupCard

NVIDIA A2

NVIDIA L4

NVIDIA A16

NVIDIA A30

Group A

NVIDIA A40

NVIDIA L40

NVIDIA A100 80GB

NVIDIA RTX A4500

NVIDIA H100

Group B

NVIDIA RTX A6000

NVIDIA RTX 6000

S

cnfgTX2550M7-20231117_ermalPage 42 of 43

PRIMERGY TX2550 M7

System configurator and

order information guide

Date of changeConfigurator revisionFolder / order code / descriptionWhat has been changed / commentName

17.11.2023

13.11.2023

26.10.2023

25.10.2023

24.10.2023

19.10.2023

18.10.2023

16.10.2023

13.10.2023

13.10.2023

13.10.2023

04.10.2023

03.10.2023

03.10.2023

22.09.2023

20.09.2023

1.51

1.50

1.49

1.48

1.47

1.46

1.45

1.44

1.43

1.43

1,42

1.41

1.40

1.39

1,38

1,37

LAN, FC_IB

19.09.2023

14.09.2023

12.09.2023

08.09.2023

04.09.2023

30.08.2023

28.08.2023

28.08.2023

31.07.2023

31.07.2023

28.07.2023

20.07.2023

1.36

1.35

1.34

1,33

1,32

1.31

1.30

1.29

1.28

1.27

1.26

1.25

19.07.2023

14.07.2023

12.07.2023

11.07.2023

04.07.2023

04.07.2023

30.06.2023

29.06.2023

22.06.2023

15.06.2023

13.06.2023

07.06.2023

1.24

1.23

1.22

1.21

1.20

1.19

1.18

1.17

1.16

1.15

1.14

1.13

06.06.2023

05.06.2023

02.06.2023

02.06.2023

02.06.2023

02.06.2023

31.05.2023

30.05.2023

23.05.2023

22.05.2023

16.05.2023

15.05.2023

26.04.2023

1.12

1.11

1.10

1.09

1.08

1.07

1.06

1.05

1.04

1.03

1.02

1.01

1.0

QLE287x released.

Change schedule info of MCX6-LX and Broadcom 25/100G cards

Other (iRMC)Add "iRMC standard/legacy Option" PYBSSS3 in others sheet.

RAMRmoved DDR5 5600 memory

HDD_SSDupdated the description about max qty for M.2 SATA/PCIe drives.

RAMAdded DDR5 Registered DIMM 5600MHz

HDD_SSDreleased SED HDD/SSD

RAIDupdated Note for Intel VROC (SATA RAID)

GFX_FPGAAdd L40S/RTX 4000

HDD_SSDupdated availability schedule

RAIDreleased Intel VROC (VMD NVMe RAID)

HDD_SSDupdated the EOL informaiton for PCIe-SSD

LANAdd I350-T2 PCIe

ODD, othersAdd new order code for half height ODDs, and current order code will be EOL

Add new TPM

RAIDreleased Intel VROC (SATA RAID)

HDD_SSDadded the limitation about VROC for PCIe-SSD

HDD_SSD, HDD_SSD (short depth)updated availability schedule

added the following drives as new products

-Samsung PM1653 as SSD SAS 2.5"

-Samsung PM897a/PM893a as SSD SATA 2.5"/3.5"

Energy Staradded E-Star Fam1/Fam2 Certification for ENERGY STAR V4.0

RAID, backupupdated availability schedule

ThermalModified thermal rule for FH PCIe/GPGPU on PCI Riser for clear information

added the EOL status for HDD SAS 15K and HDD 2.5" BC-SATA/SAS

HDD_SSD

updated availability schedules for SSD SAS "PM7"

HDD_SSD

HD_SSD, Thermaladded PDUAL CP300

PYBDMCP35, PYBDMCP35L, PY-DMCP35

PCI_riser_cardchanged chapter name to ’PCI_riser_card’ and updated description

ThermalAdding MCX6-LX 25G and P(N)225P, P(N)2100G info to Thermal sheet

HD_SSDrevised the order codes for Kioxia CM7 15.36TB

HD_SSDadded the PCIe-SSD "kioxia CM7 series"

base, PCI_RiserSeparating PCI_Riser section to Chapter 14 from Chapter 1 - base unit

LANAdding Broadcom 25G/100G cards.

Adding NVIDIA 25G cards.

Deleting E810-CQDA2 and MCX6-DX 100G FH cards because thermal level is 7

and cannot be used it as FH.

GFX_FPGADelete A30X/A100X.

FC_IBDelete the restriction of QLE277x because System T50 includes these cards and

no issues.

ThermalRevice the limitation for RTX A6000

RAIDupdated availability schedule

GFX_FPGAAdded the RTX 6000

ThermalAdded the limitation for RTX A6000

othersNo TPM for WINSVR added

ThermalModified for clear information

BaseRemoved '1x USB 3.1 Gen1(type A)' from Interfaces internal

HD_cageRemoved availability schedule for PYBBA28ST

GFX_FPGAL4/L40

updated availability schedule

RAIDadded Intel VROC (SATA RAID)

added Intel VROC Upgrade Key

PYBRLVR02, PY-RLVR02

updated availability schedule

GFX_FPGAUpdated NVLink and L4 and L40, H100.

HD_cageRemoved 'except for PCIeSSDs'

HD_SSDupdated availability schedule

ThermalAdded H100 limitation.

LANChange max number of Broadcom 10G LAN P210P, P210TP LP cards from 6 to

4.

This is due to SA:233766419. Slot#3 and slot#10 cannot be used.

HD_cageRemove the limitation for the number of disks from

PYBBA24PJ/PYBBA24PK/PYBCBE024/PYBCBE025

HD_cageAdded PY-BA34SA/PY-BA34SB/PY-BA28SQ/PY-BA28SR/PY-BA28SS/PY-

BA28ST/PY-BA24PJ/PY-BA24PK/PY-CBE024/PY-CBE025

HD_cageRemove the limitation for the number of disks from PYBBA28SS

updated availability schedule for PYBBA28ST

ThermalRevice the detail

HD_SSDremoved the BC-SATA 20TB due to release cancel

HD_SSDchanged the max qty from "2" to "1" for M.2 SSD due to not support of VROC

RAID, backupupdated availability schedule

1st release

F. Kanega

H. Ogino

H. Konno

Y. Sugiyama

T. Sudou

a

T. Sudou

T. Sudou

Y. Sugiyama

F. Kanega

H. Konno

T. Sudou

Y. Sugiyama

Y. Sugiyama

T. Sudou

Y. Sugiyama

Y. Sugiyama

T. Sudou

F. Kanega

Y. Sugiyama

Y. Sugiyama

F. Kanega

S. Fujita

T. Sudou

a

S. Fujita

K. Nishihara

S. Fujita

S. Fujita

T. Sudou

a

T. Sudou

M. Takaoka/T. Sasaki

S. Fujita

T. Sudou

S. Fujita

F. Kanega

S. Fujita

S. Fujita

S. Fujita

S. Fujita

Y. Sugiyama

Y. Sugiyama

T. Sudou

S. Fujita

cnfgTX2550M7-20231117_ange_historyPage 43 of 43

与本文相关的文章

发布评论

评论列表 (0)

  1. 暂无评论