2024年9月26日发(作者:梁丘芸芸)
PRIMERGY TX2550 M7
Tower or 4U Rack server
ChapterFolder
Cover
Description
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Base
CPU
RAM
GFX
HD_cage
RAID
ODD
Backup
HD_SSD
LAN
FC_IB
PCI_riser_card
PSU
USB_devices
Energy Star
ErP Lot9
others
Thermal
Content
List of content, Instructions for usage of this configurator,
abbreviations
System Description for easier understanding
Describes base units of TX2550 M7
Describes rack mount kits and services
Order codes, information Xeon processors
DDR5 System memory (RAM) and memory modes
Graphics-, Grid-cards, GPU and Xeon Co processors
HDD cage kits
SAS / RAID Controller and components
Optical disk drives (DVD, DVD-rw, Blu ray)
LTO drives & RDX drive
Storage drives - PCIe SSD - SAS/SATA SSD & HDD
LAN Components
Fibre Channel Controller
Infiniband Controller
PCI Riser
Power supply units, power cables, country specifics
Keyboards, Mice, USB devices
Energy Star limitation
Erp Lot9 limitation
System Management, ATD, RS232 port, TPM module
Thermal Rule
Instructions
This document contains basic product and configuration information that supports you in more complicated configurations.
In any case we recommend to use the WebArchitect to make sure, that you configure a valid system.
This System configurator is divided into several chapters. They are identical to the current price list and WebArchitect.
Please follow this document step by step from the top to the bottom
Chapter xx - description of chapter
Text fields with grey color offer extra information for related topics (e.g prerequesites, technical back
ground, configuration rules, limitations, …
S26361-F4610-E2
S26361-F4610-L3
PLAN 2x1Gb Ethern. Controller
i350-T2 chip (based on Intel Powerville) offers
2x1Gb RJ45 connectors
PCIe Gen2 x4 full height card
max. 6x per system
<-- order code E-part (bold) --
<-- order code L-part (bold)
<-- "name" of this part
<--description of this part, in same cases as well description of content
<--requires a free PCIe slot --> means total amount of PCIe slots reduced
<--indicates how often this part can be configured in the related Server
New order code
PYBVAP05
PY-VAP05
Front VGA connector (15-pin)
Front VGA connector (15-pin) including cable
and front connector
Not for 12x3.5", 24x2.5", 64xEDSFF base unit.
max. 1x per system
<-- "PYB" order code (bold) for BTO(Built to Order) part
<-- "PY-" order code (bold) for Loose delivery part
<-- "name" of this part
<--description of this part, in same cases as well description of content
<-- Limitation for this part
<--indicates how many this part can be configured in the related Server
For further information see:
Link to datasheet:
/dmsp/Publications/public/
/products/standard_servers/
(internet)
/com/order-supply/configurators/primergy_config/Pages/
(extranet)
Fujitsu is providing the content of this document with very high accuracy. In case you identify a mistake, we would kindly encourage you to inform us.
We kindly ask for understanding, that errors still may occur and that Fujitsu may change this document without notice
Abbreviations
SAS
SATA
HDD
SSD
SFF
LFF
CPU
RAID
Spaces
vSAN
storage tiering
hot data
cold data
ODD
OS
E-Part
L-Part
Drives, RAID
Drives, RAID
Drives
Drives
Drives
Drives
Processor
Drives, RAID
OS
OS
RAID
Drives
Drives
Drives
operating system
"Einbau-Part"
"Lose Lieferung-Part"
Serial attached SCSI Device (HDD, SSD, LTO drives); SAS2.0 = 6GBit/s; SAS3.0 = 12GBit/s
Serial ATA (HDD, SSD) current SATA speed = 6GBit/s
Hard disk drive (Non volatile storage device), 2.5" (SFF) or 3.5" (LFF)
Solid state disk (Non volatile storage device), 2.5" (SFF)
small form factor (=2.5")
large form factor (=3.5")
central processing unit ("processor")
RAID 0 = max speed, RAID 1 = mirroring, RAID 5 = 1 out of x drives is spare
Microsoft spaces, optimized in Win2012 R2 offers software RAID and storage tiering
offers optimized storage allocation (fast area for "hot data"; slower area for "cold data")
Data which are currently being processed
Data which are currently not processed (only stored)
optical disk drive (i.e. DVD-player, DVD-burner, Blu ray player, blu ray burner)
OS=operating system - required for running, organize and administrating the server
"e.g. S26361-F1234-E240" ordercode with "E" means it is either integrated into to Server (CPU, Mem, ..) or integrated in the
shipping box /Keyboard, Mouse, ..)
"e.g. S26361-F1234-L240" ordercode with "L" means, the part will be shipped with extra package, may be as well with extra
shipment
PRIMERGY TX2550 M7
System configurator and
order information guide
PCI Riser left (CPU2)
PCI Riser right (CPU1)
PRIMERGY TX2550 M7 rear view
cnfgTX2550M7-20231117_scriptionPage 4 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
PRIMERGY TX2550 M7 front view with drives
The front views shown below represent all possible drive options; they do not represent the base units.
For information on base units and HD drive cage for each drive option, please see chapter “base” and "HD_cage"
3.5-inch hot plug SAS/SATA
4x HDDs/SSDs8x HDDs/SSDs12x HDDs/SSDs
2.5-inch hot plug SAS/SATA/NVMe
8x HDDs/SSDs16x HDDs/SSDs16x HDDs/SSDs + 8xHDDs/SSDs/NVMes
24x HDDs/SSDs24x HDDs/SSDs + 8xHDDs/SSDs/NVMes
recommended components for TX2550 M7
Independant Mode installation
iRMC S6 advanced pack
Modular PSU 900W Titanium hot plug
#
1x
1x
2x
cnfgTX2550M7-20231117_scriptionPage 5 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
Chapter 1 - base unit
Start
Power supply units & cooling:
PRIMERGY TX2550 M7 offers bays for 2x (1x optional hot plug redundant) power supply units of 500W, 900W, 1600W, 2400W with up to 96% efficiency. 2200W with up to 94%
efficiency. Rack options ex factory or via retrofit upgrade with rack conversion kit.
Server Management:
iRMC S6 (integrated Remote Management Controller) on-board with dedicated Service LAN-port and integrated graphics controller. With onboard indicators and controls to easily
highlight failed components via LEDs displayed during service even without mains connection by simply pressing
the "indicate CSS" button. Optional ServerView Suite software incl. ServerView Installation Manager, Server View Remote Management and tools.
Platform:
Fujitsu Systemboard D3985-A made in Taiwan based on Chipset Intel® C741, up to two Xeon (Sapphire Rapids) series CPUs, four Intel® UltraPath
Interconnect (Intel® UPI) point-to-point links and onboard RAID 0/1 6Gbit/s available for up to 8x SATA drives.
16GB SD card as default
Slots: 6x PCIe slots are on board, with optional riser card up to 10x PCIe slots are available:
> 6x PCIe slots onboard, low profile, 167mm lengh, supported with first/second CPU:
Slot 1: PCIe-Gen5 x16
Slot 2: PCIe-Gen5 x16 (occupied in configurations with optional riser card)
Slot 3: PCIe-Gen5 x16 (occupied in configurations with optional riser card)
Slot 8: PCIe-Gen5 x16
Slot 9: PCIe-Gen5 x16 (occupied in configurations with optional riser card)
Slot 10: PCIe-Gen5 x16 (occupied in configurations with optional riser card)
> Optional full height riser card on PCIe slot 2/3/9/10 offers 4x additional PCIe slots, full height, 252mm and 1x PCI4/5 , with first/second CPU:
Slot 4/11: PCIe-Gen4/5 x16
Slot 5/12: PCIe-Gen4/5 x16
> Optional full height riser card on PCIe slot 2/3/9/10 offers 8x additional PCIe slots, full height, 252mm and 1x PCI4/5, with first/second CPU:
Slot 4/11: PCIe-Gen4/5 x8
Slot 5/12: PCIe-Gen4/5 x8
Slot 6/13: PCIe-Gen4/5 x8
Slot 7/14: PCIe-Gen4/5 x8
System RAM:
16x slots for DDR5-4800MHz RAM modules available (8x RAM modules per CPU). Memory speed depends on CPU and configuration.
LAN: 2x 1Gb LAN onboard;
Interfaces at rear sideInterfaces at front side
- 1x optional RS-232-C (serial port, 9 pin)- 2x USB 3.1 Gen1 (no USB wakeup)
- 2x LAN Rj45 (additional 2x RJ45 optionally available)
Interfaces internal
- 1x service LAN RJ45 (1 Gbit)
- 1x USB 3.1 Gen1 for backup devices
- 1x VGA (15 pins)
- 2x M.2
- 4x USB 3.1 Gen1
- 1x connector for TPM, 1x microSD card slot
Tower base units;
-Low noise hotplug fans
-up to 6 PCIe slots
Tower base units;
-High performance hotplug fans
-up to 10 PCIe slots
Rack base units;
-High performance hotplug fans
-up to 10 PCIe slots
C
h
o
o
s
e
o
n
e
b
a
s
e
u
n
i
t
PY TX2550 M7 Tower, 4x3.5" basic
PYT2557T3N
Tower server, expandable to 8x3.5";
Not support GPGPU
PY TX2550 M7 Tower, 8x3.5"
PYT2557TAN
Tower server, expandable to 12x3.5";
PY TX2550 M7 Rack, 8x3.5"
PYT2557R3N
Rack server, expandable to 12x3.5";
PY TX2550 M7 Tower, 8x2.5" basic
PYT2557T2N
Tower server, not expandable;
Not support GPGPU
PY TX2550 M7 Tower, 8x2.5"
PYT2557TBN
Tower server, expandable to 24x2.5";
PY TX2550 M7 Rack, 8x2.5"
PYT2557R2N
Rack server, expandable to 24x2.5";
PY TX2550 M7 Tower 4x3.5' basic and PY
TX2550 M7 Tower 8x2.5' basic do not support
Advanced Thermal design(ATD) options!
PY TX2550 M7 Tower, 24x2.5"
PYT2557TCN
Tower server, expandable to 32x2.5";
PY TX2550 M7 Rack, 24x2.5"
PYT2557RAN
Rack server, expandable to 32x2.5";
APRIMECENTER Rack
cnfgTX2550M7-20231117_sePage 6 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
Chapter 2 - Rack architecture
APRIMECENTER Rack
S26361-F2735-E111 PYBRRL6PY-RC18
No Rackmount-KitPY-RRL6
Rack conversion kit
No rackmount. Upgrade later possible
Rack Mount Kit F2-C S7 LV
Contains all necessary parts to convert PRIMERGY TX2550
with L-part
telescopic drop-in rail, full extractical, supports 1-
M7 Tower Server into a Rack server.
max. 1x per system
hand-mounting
Rackmount Kit ex factory
Rack mounting kit has to be ordered seperately.
> 1 pair of vario carrier with variable length & quick
release lever support
> 1 pair of telescopic drop-in rails with Cable
Management Arm (CMA) adapter
1x per system
S26361-F2735-E82
S26361-F2735-L82
2U cable management arm (CMA) for
2U server or higher
for mounting in symmetrical
PRIMECENTER M2/M1 racks
- 1 bracket PC M2/M1 Rack
1x per system
S26361-F1647-E302
Installation ex factory in a PRIMECENTER Rack
The installation service is to be ordered once per installable server/storage
Fujitsu will deliver the PRIMERGY mounted in a Rack System and all wired
subsystem, in order to get the server/storage subsystem mounted into the
connections are tested with PRIMECENTER rack - Systems and components will be
racks. In case of the 46 U PCR S2 this service has to be ordered, to get the
delivered installed in the rack
mounting kits and the cables installed.
max. 1x per System
B
cnfgTX2550M7-20231117_sePage 7 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
Chapter 3 - CPU
B
General Discription
There are 2 processor sockets available. Please configure 1 or 2 Processors.
>> All processors have to be the same type.
>> With one processor iRMC, 3x PCIe low profile slots(Up to 1x PCIe low profile + 4x PCIe full height) and 8x DIMM slots are available
>> With two processors all 16x DIMM slots, 6x PCIe low profile slots are available. Up to 2x PCIe low profile + 8x PCIe full height.
>> To configure 2nd CPU an additional cooler kit is required.
* HT = Hyper Threading
Notice
** Base Unit is not including CPUs. Minimum 1x CPU is required to be configured in one base unit.
** Maximum 2x CPUs are allowed to be configured in one base unit. Only 1 type of CPU can be configured in one base unit.
**CPU: PYBCP65XR, PYBCP65XS and PYBCP65X1 are not allowed to be configured 2x CPUs
CPU Group for
Thermal condition
Xeon Bronze 34xx - Mainline, 1 socket configuration only(BTO)(Loose delivery)
64-bit Intel Xeon processor supporting HT*, DDR5 @ 4000 MT/s
Xeon Bronze 3408U 8C 1.8GHz 125WPYBCP65XR-A
MCC
Xeon Silver 44xx - Mainline, 2 socket scalability(BTO)(Loose delivery)
64-bit Intel Xeon processor supporting HT*, DDR5 @ 4000 MT/s & UPI Bus (2UPI) @ 16 GT/s
Xeon Silver 4410Y 12C 2.0GHz 150W Speed Select TechnologyPYBCP66XGPY-CP66XGA
MCC
Xeon Silver 4416+ 20C 2.0GHz 165WPYBCP66XHPY-CP66XHB
MCC
Xeon Gold 54xx - Mainline/Performance Optimized, 1 socket configuration only(BTO)(Loose delivery)
64-bit Intel Xeon processor supporting HT*, DDR5 @ 4400 MT/s
Xeon Gold 5412U 24C 2.1GHz 185WPYBCP65XS-B
MCC
Xeon Gold 54xx - Mainline/Performance Optimized, 2 socket scalablity(BTO)(Loose delivery)
64-bit Intel Xeon processor supporting HT*, DDR5 @ 4400 MT/s & UPI Bus (3UPI) @ 16 GT/s
Xeon Gold 5415+ 8C 2.9GHz 150WPYBCP65XTPY-CP65XTA
MCC
Xeon Gold 5418Y 24C 2.0GHz 185W Speed Select TechnologyPYBCP65XWPY-CP65XWB
MCC
Xeon Gold 5420+ 28C 2.0GHz 205WPYBCP65XXPY-CP65XXB
MCC
Xeon Gold 64xx - Mainline/Performance Optimized, 1 socket configuration only(BTO)(Loose delivery)
64-bit Intel Xeon processor supporting HT*, DDR5 @ 4800(1DPC) / 4400(2DPC) MT/s
Xeon Gold 6414U 32C 2.0GHz 250WPYBCP65X1-C
XCC
Xeon Gold 64xx - Mainline/Performance Optimized, 2 socket scalability(BTO)(Loose delivery)
64-bit Intel Xeon processor supporting HT*, DDR5 @ 4800(1DPC) / 4400(2DPC) MT/s & UPI Bus (3UPI) @ 16 GT/s
Xeon Gold 6426Y 16C 2.5GHz 185W Speed Select TechnologyPYBCP66X2PY-CP66X2B
MCC
Xeon Gold 6430 32C 2.1GHz 270W (DDR5 @ 4400(1DPC/2DPC)) PYBCP65X2PY-CP65X2D
XCC
Xeon Gold 6434 8C 3.7GHz 195WPYBCP66X4PY-CP66X4B
MCC
Xeon Gold 6438Y+ 32C 2.0GHz 205W Speed Select TechnologyPYBCP66X8PY-CP66X8B
MCC
Xeon Gold 6442Y 24C 2.6GHz 225W Speed Select TechnologyPYBCP66X9PY-CP66X9C
MCC
Xeon Gold 6448Y 32C 2.1GHz 225W Speed Select TechnologyPYBCP66XCPY-CP66XCC
MCC
Xeon Platinum 84xxH - IMDB/Analytics Workload Optimized, 8 socket scalability(BTO)(Loose delivery)
64-bit Intel Xeon processor supporting HT*, DDR5 @ 4800(1DPC) / 4400(2DPC) MT/s & UPI Bus (4UPI) @ 16 GT/s
Xeon Platinum 8444H 16C 2.9GHz 270WPYBCP65X4PY-CP65X4D
XCC
Xeon Platinum 8450H 28C 2.0GHz 250W Speed Select TechnologyPYBCP65X6PY-CP65X6C
XCC
Xeon - Storage & HCI Workload Optimized, 2 socket scalability(BTO)(Loose delivery)
64-bit Intel Xeon processor supporting HT*, DDR5 @ 4800(1DPC) / 4400(2DPC) MT/s & UPI Bus (3UPI) @ 16 GT/s
Xeon Gold 5416S 16C 2.0GHz 150W (DDR5 @ 4400(1DPC/2DPC)) Speed Select TechnoPYBCP65XUPY-CP65XUA
MCC
Xeon Gold 6454S 32C 2.2GHz 270W Speed Select TechnologyPYBCP65X3PY-CP65X3D
XCC
Xeon - Long-Life Use (IOT) Workload Optimized, 2 socket scalability(BTO)(Loose delivery)
64-bit Intel Xeon processor supporting HT*, DDR5 @ 4000 MT/s & UPI Bus (2UPI) @ 16 GT/s
Xeon Silver 4410T 10C 2.7GHz 150W Speed Select TechnologyPYBCP66XFPY-CP66XFA
MCC
Notice
2CPU configuration require to order 2nd CPU cooler kit
CPU Cooler kit(BTO)(Loose delivery)
2nd CPU Cooler kit for Basic model***PYBTKCPC85-
2nd CPU Cooler kit****PYBTKCPC86-
CPU cooler kit for loose delivery CPU for Basic model***-PY-TKCPC85
CPU cooler kit for loose delivery CPU****-PY-TKCPC86
*** For PYT2557T3N/PYT2557T2N
**** For PYT2557TAN/PYT2557TBN/PYT2557TCN/PYT2557R3N/PYT2557R2N/PYT2557RAN
C
cnfgTX2550M7-20231117_UPage 8 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
Chapter 4 - DDR5 System memory
C
Each CPU offers 8 Slots for DDR5 Memory Modules organised in 1 Banks and 8 Channels with 4 Memory Controllers (2 Channels each).
If you need more than 8 Slots you have to configure 2nd CPU.
Depending on the amount of memory configured you can decide between the Normal Memory RAS mode or the Mirroring Memory RAS Mode.
There are different kinds of DDR5 Memory Modules available: RDIMM x4, RDIMM x8, RDIMM 3DS x4.
Mix of different memories is not allowed.
Supported memory capacities per CPU:
Up to 2TB using DDR5 RDIMM (8x 256GB DDR5 RDIMM 3DS)
Supported memory capacities per System (with 2CPU configuration):
Up to 4TB using DDR5 RDIMM (16x 256GB DDR5 RDIMM 3DS)
The memory speed depends on configuration restricted by the CPU SKU (max. 4800 MT/s).
DDR5 memory is operated at 1.1V
Memory Mode ; One of followig memory modes must be selected.
Independent ModeRequires 1, 2, 4, 6 or 8 Memory Modules per CPU1x per CPUPYBMMD2
Independent Mode required to be the best performance.
ADDDC Sparing is available in case system configured by DDR5 xRx4 DIMM only.
Mirroring ModeRequires 8 Memory Modules per CPU1x per CPUPYBMMC4
BIOS preconfiguration for Mirroring mode. 8x identical memory modules are always equipped on same bank across all channels to use the mirrored channel mode. Half of the
modules contain active data, the remaining modules contain mirrored data.
min/max 1x per CPU; max 2x for System
DDR5 DIMM only configuration section
Min 1x DIMM per CPU is required. Any Mix of RDIMMx8, RDIMMx4, RDIMM 3DS is not allowed.
DDR5 Registered DIMM 4800MHz 1R/2R x8
16GB (1x16GB) 1Rx8 DDR5-4800 R ECC
max 8x per CPUPYBME16SLPY-ME16SL
32GB (1x32GB) 2Rx8 DDR5-4800 R ECC
max 8x per CPUPYBME32SLPY-ME32SL
max 8x per CPU; max 16x for System
DDR5 Registered DIMM 4800MHz 1R/2R x4
32GB (1x32GB) 1Rx4 DDR5-4800 R ECC
max 8x per CPUPYBME32SL2PY-ME32SL2
64GB (1x64GB) 2Rx4 DDR5-4800 R ECC
max 8x per CPUPYBME64SLPY-ME64SL
max 8x per CPU; max 16x for System
DDR5 Registered DIMM 4800MHz 3DS 4R/8R x4
128GB (1x128GB) 4Rx4 DDR5-4800 R 3DS ECC
max 8x per CPUPYBME12SLPY-ME12SL
256GB (1x256GB) 8Rx4 DDR5-4800 R 3DS ECC
max 8x per CPUPYBME25SLPY-ME25SL
max 8x per CPU; max 16x for System
D
cnfgTX2550M7-20231117_MPage 9 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
Detailed information
RAS feature
ECC
SDDC
ADDDC Sparing
Mirroring channel
Memory Mode
Normal Mode/Mirroring Mode
Normal Mode/Mirroring Mode
Normal Mode
Mirroring Mode
RDIMM
x8
yes
no
no
yes
RDIMM
LRDIMM
x4
yes
yes
yes
yes
BIOS setting
always enabled.
always enabled in case x4 DIMM conifugred.
disabled as default.
enabled in case Mirroring Mode ordered.
Configuration
Min. Memory
Max. Memory per CPU
Max. Memory per System
DIMM
1 Module / CPU
8 Module / CPU
16 Modules / CPU
32 Modules / System
CPU
with one CPU
with one CPU
with two CPU
with two CPU
Normal Mode
16GB: 16GB x1
-
2TB: 256GB x8
4TB: 256GB x16
Available Capacity
Mirroring Mode
-
64GB: 16GBx8x50%
1TB: 256GBx8x50%
2TB: 256GBx16x50%
The memory sockets on the Systemboards are color coded
C
h
a
n
n
e
l
G
C
h
a
n
n
e
l
A
C
h
a
n
n
e
l
B
C
h
a
n
n
e
l
C
C
h
a
n
n
e
l
D
Bank Iblack sockets
iMC0iMC1
CPU
iMC2iMC3
Normal Mode population DDR5 DIMM only
Normal Mode requires 1x, 2x, 4x, 6x or 8x DIMM configuration per CPU.
for 2x or more than 2x DIMM configuration,
Between Chanel A-E/C-G/B-F/D-H, balanced configuration is required. same bank of each chanel need to be populatd.
Between Chanel A-C-E-G/B-D-F-H, each chanel capacity need to be same if DIMM poputated in each Chanel.
1 DIMMs for 1CPU1 DIMMs for 1CPU
C
h
a
n
n
e
l
G
C
h
a
n
n
e
l
H
C
h
a
n
n
e
l
E
C
h
a
n
n
e
l
F
C
h
a
n
n
e
l
G
C
h
a
n
n
e
l
A
C
h
a
n
n
e
l
B
C
h
a
n
n
e
l
C
C
h
a
n
n
e
l
D
C
h
a
n
n
e
l
H
C
h
a
n
n
e
l
A
C
h
a
n
n
e
l
B
C
h
a
n
n
e
l
C
C
h
a
n
n
e
l
D
Data
iMC0iMC1
CPU
1 DIMMs for 1CPU1 DIMMs for 1CPU
iMC2iMC3iMC0iMC1
CPU
Data
iMC2iMC3
C
h
a
n
n
e
l
G
C
h
a
n
n
e
l
G
C
h
a
n
n
e
l
A
C
h
a
n
n
e
l
B
C
h
a
n
n
e
l
C
C
h
a
n
n
e
l
D
C
h
a
n
n
e
l
H
C
h
a
n
n
e
l
A
C
h
a
n
n
e
l
B
C
h
a
n
n
e
l
C
C
h
a
n
n
e
l
D
Data
iMC0iMC1
CPU
iMC2iMC3iMC0iMC1
CPU
iMC2
Data
iMC3
cnfgTX2550M7-20231117_M
C
h
a
n
n
e
l
H
C
h
a
n
n
e
l
E
C
h
a
n
n
e
l
E
C
h
a
n
n
e
l
F
C
h
a
n
n
e
l
F
C
h
a
n
n
e
l
H
C
h
a
n
n
e
l
E
C
h
a
n
n
e
l
E
C
h
a
n
n
e
l
F
C
h
a
n
n
e
l
F
Page 10 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
2 DIMMs for 1CPU
2x identical memory modules need to be populated.
2 DIMMs for 1CPU
2x identical memory modules need to be populated.
C
h
a
n
n
e
l
G
C
h
a
n
n
e
l
G
C
h
a
n
n
e
l
A
C
h
a
n
n
e
l
B
C
h
a
n
n
e
l
C
C
h
a
n
n
e
l
D
C
h
a
n
n
e
l
H
C
h
a
n
n
e
l
A
C
h
a
n
n
e
l
B
C
h
a
n
n
e
l
C
C
h
a
n
n
e
l
D
Data
iMC0iMC1
CPU
4 DIMMs for 1CPU
4x identical memory modules need to be populated.
iMC2
Data
iMC3iMC0
Data
iMC1
CPU
Data
iMC2iMC3
6 DIMMs for 1CPU
6x identical memory modules need to be populated.
C
h
a
n
n
e
l
G
C
h
a
n
n
e
l
G
C
h
a
n
n
e
l
A
C
h
a
n
n
e
l
B
C
h
a
n
n
e
l
C
C
h
a
n
n
e
l
D
C
h
a
n
n
e
l
H
C
h
a
n
n
e
l
A
C
h
a
n
n
e
l
B
C
h
a
n
n
e
l
C
C
h
a
n
n
e
l
D
Data
iMC0
Data
iMC1
CPU
Data
iMC2
Data
iMC3
Data
iMC0
Data
iMC1
DataData
iMC2
CPU
DataData
iMC3
6 DIMMs for 1CPU
6x identical memory modules need to be populated.
6 DIMMs for 1CPU
6x identical memory modules need to be populated.
C
h
a
n
n
e
l
G
C
h
a
n
n
e
l
G
C
h
a
n
n
e
l
A
C
h
a
n
n
e
l
B
C
h
a
n
n
e
l
C
C
h
a
n
n
e
l
D
C
h
a
n
n
e
l
H
C
h
a
n
n
e
l
A
C
h
a
n
n
e
l
B
C
h
a
n
n
e
l
C
C
h
a
n
n
e
l
D
Data
iMC0
DataData
iMC1
CPU
Data
iMC2
Data
iMC3
Data
iMC0
DataData
iMC1
DataData
iMC2
CPU
Data
iMC3
Data
6 DIMMs for 1CPU
6x identical memory modules need to be populated.
8 DIMMs for 1CPU
8x identical memory modules need to be populated.
C
h
a
n
n
e
l
G
C
h
a
n
n
e
l
G
C
h
a
n
n
e
l
A
C
h
a
n
n
e
l
B
C
h
a
n
n
e
l
C
C
h
a
n
n
e
l
D
C
h
a
n
n
e
l
H
C
h
a
n
n
e
l
A
C
h
a
n
n
e
l
B
C
h
a
n
n
e
l
C
C
h
a
n
n
e
l
D
Data
iMC0
Data
iMC1
Data
iMC2
CPU
DataData
iMC3
DataData
iMC0
DataData
iMC1
DataData
iMC2
CPU
DataData
iMC3
Data
Mirroring Mode population DDR5 DIMM only
Mirroring Mode requires 8x or 16x DIMM configuration per CPU.
in addition to Normal Mode Memory population rules,
Between Chanel A-B/C-D/E-F/G-H, identical DIMM need to be populated in same bank.
8 DIMMs for 1CPU
C
h
a
n
n
e
l
G
C
h
a
n
n
e
l
A
C
h
a
n
n
e
l
B
C
h
a
n
n
e
l
C
C
h
a
n
n
e
l
D
DataMirror
iMC0
DataMirror
iMC1
CPU
DataMirror
iMC2
DataMirror
iMC3
cnfgTX2550M7-20231117_
C
h
a
n
n
e
l
H
C
h
a
n
n
e
l
E
C
h
a
n
n
e
l
F
RAM
C
h
a
n
n
e
l
H
C
h
a
n
n
e
l
E
C
h
a
n
n
e
l
E
C
h
a
n
n
e
l
F
C
h
a
n
n
e
l
F
C
h
a
n
n
e
l
H
C
h
a
n
n
e
l
E
C
h
a
n
n
e
l
E
C
h
a
n
n
e
l
F
C
h
a
n
n
e
l
F
C
h
a
n
n
e
l
H
C
h
a
n
n
e
l
E
C
h
a
n
n
e
l
E
C
h
a
n
n
e
l
F
C
h
a
n
n
e
l
F
C
h
a
n
n
e
l
H
C
h
a
n
n
e
l
E
C
h
a
n
n
e
l
E
C
h
a
n
n
e
l
F
C
h
a
n
n
e
l
F
Page 11 of 43
The different GPU mixed configuration
does NOT support.
The different GPU mixed configuration
does NOT support.
These combination between RTX series and these Adapters(S26361-F4066-E12/L12,
S26361-F4066-E13/L13) are ristriction. It will be avaiable in 09.2023
FPGA Card T.B.D. to be available from GA
PRIMERGY TX2550 M7
System configurator and
order information guide
Chapter 6 - HD drive cage
F
HD drive cage is a metal box providing bays for 3.5" HDDs or 2.5" HDDs/SSDs/PCIe-SSDs. Choose out of the
following HD cage upgrade kits, depending on pre-selected TX2550 M7 base unit and the targeted configuration. Each upgrade kit contains all relevant
parts such as metal cage, backplane, cables and mounting material.
Upgrade kits for the upper drive area require the completion of the mid drive area.
Up to 3x 1.6x5.25" bays are available in the upper drive area for an ODD and/or backup drive configurations; in the 12x3.5" configuration, a 9.5mm bay is
available for a slim ODD. Refer to sections "ODD" and "backup" for details.
Upgrade kits are available either ex-factory (E-codes) or as loose delivery party (L-codes).
RAID configurations are recommendations; refer to section "RAID" for available options.
Preferred slots for controller assignementGeneral drive numbering scheme
Rear side view (incl. riser card option; refer to sheet "Description" for details)
TX2550 M7 front views of expandable base units and corresponding HD drive cage options:
If you change channel for HBA- or RAID-Controller as loose delivery, SAS cable need to be changed.
Option BPY-CBS085SAS cable for CP2100-8i
Option CPY-CBS086SAS cable for CP6xx/EP6xx/EP32xx
Base Unit
PY TX2550 M7 Tower, 4x3.5" basic
PYT2557T3N
RAID configuration1x HBA- or RAID-Controller. Refer to section "RAID" for options. Onboard SATA (max. 8x disks)
ODD / Backup3x 1.6x5.25" bays are available for an optical and/or backup drives in the upper drive area.
Upgrade kit for 4x3.5" HDD
PYBBA34SAPY-BA34SA
Upgrade kit for 4x3.5" HDD, mounted in the mid
drive area
Base Unit
PY TX2550 M7 Tower, 8x3.5"PY TX2550 M7 Rack, 8x3.5"
PYT2557TANPYT2557R3N
RAID configuration1x HBA- or RAID-Controller. Refer to section "RAID" for options. onboard SATA(Max. qty. for Disk is eight.)
if no upper drive area is installed, the below can be selected.
ODD / Backup3x 1.6x5.25" bays are available for an optical and/or backup drives in the upper drive area.
HD cage upgrades for upper drive area
Upgrade kit for 4x3.5" HDD
PYBBA34SBPY-BA34SB
Upgrade kit for 4x3.5" HDD, mounted in the
upper drive area,
incl. 40x SAS Expander
1x 9.5mm bay is available for a slim optical drive
in the upper drive area.
Note! This option requires 1x PRAID/HBA per
Base unit
RAID configuration1x HBA- or RAID-Controller. Refer to section "RAID" for options.
ODD / Backup1x 9.5mm bay is available for a slim optical drive in the upper drive area.
Base Unit
PY TX2550 M7 Tower, 8x2.5" basic
PYT2557T2N
RAID configuration1x HBA- or RAID-Controller. Refer to section "RAID" for options. onboard SATA(Max. qty. for Disk is eight.)
ODD / Backup3x 1.6x5.25" bays are available for an optical and/or backup drives in the upper drive area.
cnfgTX2550M7-20231117__cagePage 14 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
Base unit
PY TX2550 M7 Tower, 8x2.5"PY TX2550 M7 Rack, 8x2.5"
PYT2557TBNPYT2557R2N
RAID configuration1x HBA- or RAID-Controller. Refer to section "RAID" for options. onboard SATA(Max. qty. for Disk is eight.)
if no upper drive area is installed, the below can be selected.
ODD / Backup3x 1.6x5.25" bays are available for an optical and/or backup drives in the upper drive area.
HD cage upgrades
Upgrade kit for 8x2.5" HDDUpgrade kit for 8x2.5" HDD
PYBBA28SQPY-BA28SQPYBBA28SRPY-BA28SR
Upgrade kit for 8x2.5" HDD, mounted in the mid Upgrade kit for 8x2.5" HDD, mounted in the mid
drive area,drive area,
for connect 16port RAID option
incl. 40x SAS Expander
Note! This option requires 1x 16-channel
PRAID/HBA
Note! This option requires 1x PRAID/HBA
Upgrade kit for the upper drive area
Please refer to “Upgrade kit for the upper drive area with PYT2557TBN/ PYT2557R2N/ PYT2557TCN/ PYT2557RAN
Base unit
PY TX2550 M7 Tower, 24x2.5"PY TX2550 M7 Rack, 24x2.5"
PYT2557TCNPYT2557RAN
Including 40x SAS Expander!
RAID configuration1x HBA- or RAID-Controllers. Refer to section "RAID" for options.
ODD / Backup3x 1.6x5.25" bays are available for an optical and/or backup drives in the upper drive area.
HD cage upgrades
Upgrade kit for the upper drive area
Please refer to “Upgrade kit for the upper drive area with PYT2557TBN/ PYT2557R2N/ PYT2557TCN/ PYT2557RAN
cnfgTX2550M7-20231117__cagePage 15 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
The mix configuration information
Upgrade kit for the upper drive area with PYT2557TBN/ PYT2557R2N/ PYT2557TCN/ PYT2557RAN
Only one of them can be selected.
Upgrade kit for 8x2.5" HDD
PYBBA28SS
8x2.5"
PY-BA28SS
Upgrade kit for 8x2.5" HDD(SAS4)8x2.5" combo HDD
Note!
This option requires 2x CPUs.
This option requires min. 1x 24Gb/s PRAID/HBA
In total, 2x PRAID/ HBA are allowed (1x for bottom / mid area,
1x for upper area). Choose from the options below:
PYBBA28ST
[Option 1] – Choose two of the following:
- 1x for bottom / mid area :
PRAID EP 325x-xi [PYBSR4MA1L/PY-
SR4MA1/PYBSR4MA2L/PY-SR4MA2/PYBSR4MA3L/PY-
SR4MA3],
or PSAS CP 2200-16i [PYBSC4MA1L/PY-SC4MA1]
or PSAS CP 2100-8i [PYBSC3MA2L/PY-SC3MA2].
- 1x for upper area :
PRAID EP 325x-xi [PYBSR4MA1L/PY-
SR4MA1/PYBSR4MA2L/PY-SR4MA2/PYBSR4MA3L/PY-
SR4MA3],
or PSAS CP 2200-16i [PYBSC4MA1L/PY-SC4MA1]
PY-BA28ST
[Option 2] – Choose two of the following:
- 1x for bottom / mid area :
PSAS CP600i[PYBSC4FAL/PY-SC4FA],
or PRAID CP600i[PYBSR4FAL/PY-SR4FA],
or PRAID EP740i[PYBSR4C71L/PY-SR4C71],
or PRAID EP6x0i[PYBSR4C63L/PY-SR4C63/PYBSR4C6L/PY-
SR4C6]
- 1x for upper area :
Upgrade kit for 1-4 x2.5" PCIe SSD SFF w/
PYBBA24PJ
8x2.5" combo HDD
onBoard
PY-BA24PJ
Upgrade kit for 1-4 x2.5" PCIe SSD SFF w/
PYBBA24PK
8x2.5" combo HDD
PRAID
Note!
PY-BA24PK
This option requires 1x PRAID for NVMe.
upgrade kit for 5-8 x2.5" PCIe SSD SFF w/
PYBCBE024
Note!
onBoardThis option requires 2x CPUs.
PY-CBE024
This option requires PYBBA24PJ.
Upgrade kit for 5-8 x2.5" PCIe SSD SFF w/ Note!
PRAID
PYBCBE025
This option requires 2x CPUs.
PY-CBE025
This option requires another PRAID for NVMe.
This option requires PYBBA24PK.
RAID configurationHBA- or RAID- or Retimer-Controllers. Refer to section "RAID" for options.
ODD / Backup
1x 1.6x5.25" bay is available for an optical or backup drive in the upper drive area.
Note! One of LTO and ODD can be selected.
G
cnfgTX2550M7-20231117__cagePage 16 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
Chapter 7 - SAS / RAID Controller
G
FH PCIe card requires FH PCIe riser card. Please refer to ''Chapter 14 - PCI riser card'.
onboard SATA controller with SW-RAID
onboard controller for SATA HDD or SSD drives
6Gb/s SATAIntel VROC (SATA RAID) based on chipset
BIOS version R1.6.0 or later is required to use Intel VROC (SATA RAID)
No CacheSW-RAID 0, 1, 102xonboard, included
intenal HBA and RAID controller, no 2nd Level cache
internal RAID / HBA controllers for SAS, SATA HDD or SSD drives
RAID 0, 1, 10
PRAID CP600i LPNo Cache
8 ports 3, 6 & 12Gb/s SAS/SATA HDD/SSD, supports up to 8 drives without expander
supports SED (Self Encrypting Drives)
requires 1x LP PCIe 4.0 x8 (int.) slot, based on LSI SAS3808
HBA, no RAID
PSAS CP600i LPNo Cache
16 ports 3, 6 & 12Gb/s SAS/SATA HDD/SSD, supports up to 16 drives without expander
limitation: supports up to 30 drives only with expander
requires 1x LP PCIe 4.0 x8 (int.) slot, based on LSI SAS3816; IT FW stack without RAID functionality
PYBSR4FAL
PY-SR4FA
PYBSC4FALPY-SC4FA
internal RAID / HBA controllers for SAS, SATA HDD or SSD drives
HBA + RAID 0, 1, 10, 5PYBSC4MA1LPY-SC4MA1
No Cache
PSAS CP 2200-16i LP available from 2024/03
16 ports 6, 12 & 24Gb/s SAS/SATA HDD/SSD, supports up to 16 SAS/SATA drives without expander
(the configuration for up to 4 x4 NVMe drives requires a different order number, please see below)
supports SED (Self Encrypting Drives)
requires 1x LP PCIe 4.0 x8 (int.) slot
* max. 2x, when Upgrade kit for 8x2.5" HDD(SAS4): PYBBA28ST is ordered
(FYI: PYBSC4MA1L and PYBSC4MA2(L) are identical products. The 2nd Order number was only introduced for explicite ordering and cabling)
HBA + RAID 0, 1, 10, 5
PSAS CP 2100-8i LPNo Cache
8 ports 3, 6 & 12Gb/s SAS/SATA HDD/SSD, supports up to 8 devices without expander
requires 1x LP PCIe 3.0 x8 (int.) slot
PYBSC3MA2LPY-SC3MA2
internal RAID / HBA controllers for PCIe SSD drives
HBA + RAID 0, 1, 10, 5PYBSC4MA2
No Cache
PSAS CP 2200-16i NVMe FH
available from 2024/03
PY-SC4MA1
HBA + RAID 0, 1, 10, 5PYBSC4MA2L
No Cache
PSAS CP 2200-16i NVMe LP
available from 2024/03
up to 4 x4 NVMe drives are supported. (the configuration for SAS/SATA only requires a different order number, please see above)
requires 1x FH or LP PCIe 4.0 x8 (int.) slot
(FYI: PYBSC4MA1L and PYBSC4MA2(L) are identical products. The 2nd Order number was only introduced for explicite ordering and cabling)
internal RAID controller with 2nd Level cache
internal RAID controllers for SAS, SATA HDD or SSD drives
PYBSR4C71LPY-SR4C71
PRAID EP740i LP available from 2024/07
4GB Cache
RAID 0, 1, 10, 5, 50, 6, 60
16 ports 6, 12 & 24Gb/s SAS/SATA HDD/SSD, supports up to 16 SAS/SATA drives without expander
(the configuration for up to 4 x4 NVMe drives requires a different order number, please see below)
supports SED (Self Encrypting Drives)
requires 1x LP PCIe 4.0 x8 (int.) slot, based on LSI SAS4116
* max. 2x, when Upgrade kit for 8x2.5" HDD(SAS4): PYBBA28ST is ordered
(FYI: PYBSR4C71L and PYBSR4C72(L) are identical products. The 2nd Order number was only introduced for explicite ordering and cabling)
internal RAID controllers for SAS, SATA HDD or SSD drives
PRAID EP640i LP4GB Cache
RAID 0, 1, 10, 5, 50, 6, 60
8 ports 3, 6 & 12Gb/s SAS/SATA HDD/SSD, supports up to 8 drives without expander
supports SED (Self Encrypting Drives)
requires 1x LP PCIe 4.0 x8 (int.) slot, based on LSI SAS3908
PYBSR4C63LPY-SR4C63
PRAID EP680i LP8GB CachePYBSR4C6LPY-SR4C6
RAID 0, 1, 10, 5, 50, 6, 60
16 ports 3, 6 & 12Gb/s SAS/SATA HDD/SSD, supports up to 16 SAS/SATA drives without expander
(the configuration for up to 4 x4 NVMe drives requires a different order number, please see below)
supports SED (Self Encrypting Drives)
requires 1x LP PCIe 4.0 x8 (int.) slot, based on LSI SAS3916
(FYI: PYBSR4C6L and PYBSR4C62(L) are identical products. The 2nd Order number was only introduced for explicite ordering and cabling)
optional Flash Backup Unit (FBU)
FBU option for PRAID EP6xx / EP7xx: Supercap securing the power supply of the RAID controller in case of
S26361-F4042-E155
power failure including cable with 55cm length
S26361-F4042-L110
cnfgTX2550M7-20231117_IDPage 17 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
internal RAID controllers for PCIe SSD drives
4GB CachePYBSR4C72
PRAID EP740i NVMe FH
available from 2024/07
RAID 0, 1, 10, 5, 50, 6, 60
PY-SR4C71
4GB CachePYBSR4C72L
PRAID EP740i NVMe LP
available from 2024/07
RAID 0, 1, 10, 5, 50, 6, 60
up to 4 x4 NVMe drives are supported. (the configuration for SAS/SATA only requires a different order number, please see above)
requires 1x FH or LP PCIe 4.0 x8 (int.) slot, based on LSI SAS4116
(FYI: PYBSR4C71L and PYBSR4C72(L) are identical products. The 2nd Order number was only introduced for explicite ordering and cabling)
optional Flash Backup Unit (FBU)
S26361-F4042-L110
FBU option for PRAID EP7xx: Supercap securing the power supply of the RAID controller in case of power
S26361-F4042-E155
failure including cable with 55cm length
internal RAID controllers for PCIe SSD drives
PRAID EP680i NVMe FH8GB CachePYBSR4C62
RAID 0, 1, 10, 5, 50, 6, 60
PY-SR4C6
PRAID EP680i NVMe LP8GB CachePYBSR4C62L
RAID 0, 1, 10, 5, 50, 6, 60
up to 4 x4 NVMe drives are supported. (the configuration for SAS/SATA only requires a different order number, please see above)
no FBU is allowed for this controller
requires 1x FH or LP PCIe 4.0 x8 (int.) slot, based on LSI SAS3916
(FYI: PYBSR4C6L and PYBSR4C62(L) are identical products. The 2nd Order number was only introduced for explicite ordering and cabling)
internal RAID controllers for SAS, SATA HDD or SSD drives
PRAID EP 3252-8i LP2GB Cache
RAID 0, 1, 10, 5, 50, 6, 60
PRAID EP 3254-8i LP4GB Cache
RAID 0, 1, 10, 5, 50, 6, 60
8 ports 6, 12 & 24Gb/s SAS/SATA HDD/SSD, supports up to 8 drives without expander
supports SED (Self Encrypting Drives)
requires 1x LP PCIe 4.0 x8 (int.) slot
* max. 2x, when Upgrade kit for 8x2.5" HDD(SAS4): PYBBA28ST is ordered
PYBSR4MA1L
PYBSR4MA2L
PY-SR4MA1
PY-SR4MA2
PRAID EP 3258-16i LP8GB CachePYBSR4MA3LPY-SR4MA3
RAID 0, 1, 10, 5, 50, 6, 60
16 ports 6, 12 & 24Gb/s SAS/SATA HDD/SSD, supports up to 16 SAS/SATA drives without expander
(the configuration for up to 4 x4 NVMe drives requires a different order number, please see below)
supports SED (Self Encrypting Drives)
requires 1x LP PCIe 4.0 x8 (int.) slot
* max. 2x, when Upgrade kit for 8x2.5" HDD(SAS4): PYBBA28ST is ordered
(FYI: PYBSR4MA3L and PYBSR4MA4(L) are identical products. The 2nd Order number was only introduced for explicite ordering and cabling)
optional Flash Backup Unit (FBU)
FBU option for PRAID EP 325x in rear PCIe Slot#1: Supercap securing the power supply of the RAID
controller in case of power failure without extension cable
FBU option for PRAID EP 325x in rear PCIe Slot#8: Supercap securing the power supply of the RAID
controller in case of power failure including cable with 46cm length
PYBFBM014
PYBFBM012
PY-FBM01
PY-FBM01
internal RAID controllers for PCIe SSD drives
PRAID EP 3258-16i NVMe FH8GB CachePYBSR4MA4
RAID 0, 1, 10, 5, 50, 6, 60
PY-SR4MA3
PRAID EP 3258-16i NVMe LP8GB CachePYBSR4MA4L
RAID 0, 1, 10, 5, 50, 6, 60
available from 2024/03
up to 4 x4 NVMe drives are supported. (the configuration for SAS/SATA only requires a different order number, please see above)
requires 1x FH or LP PCIe 4.0 x8 (int.) slot
(FYI: PYBSR4MA3L and PYBSR4MA4(L) are identical products. The 2nd Order number was only introduced for explicite ordering and cabling)
optional Flash Backup Unit (FBU) available from 2024/03
FBU option for PRAID EP 325x in rear PCIe Slot#3/#4/#8: Supercap securing the power supply of the RAID
PYBFBM012
controller in case of power failure including cable with 46cm length
PY-FBM01
FBU cannot be combined with Advanced Thermal design.
up to 3x FBU can be integrated per System
Group A and Group B cannot be mixed
Group A and Group C can be mixed
Group B and Group C can be mixed
Group AGroup B
PSAS CP600iPSAS CP 2100-8i
PSAS CP600i for LTOPSAS CP 2200-16i
PRAID CP600iPSAS CP 2200-16i NVMe
PRAID EP740iPSAS CP 2200-16i for LTO
PRAID EP740i NVMePRAID EP 3252-8i
PRAID EP640iPRAID EP 3254-8i
PRAID EP680iPRAID EP 3258-16i
PRAID EP680i NVMePRAID EP 3258-16i NVMe
Group C
PSAS CP600e
PRAID EP680e
cnfgTX2550M7-20231117_IDPage 18 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
H
external HBA controller, no 2nd Level cache
external HBA controllers for SAS HDD or SSD drives
HBA, no RAID
PSAS CP600e FHNo Cache
HBA, no RAID
PSAS CP600e LPNo Cache
16 ports 3, 6 & 12Gb/s SAS/SATA HDD/SSD, 4x SFF8644 (external Mini-SAS HD)
requires 1x FH or LP PCIe 4.0 x8 (int.) slot, based on LSI SAS3816
PYBSC4FAE
PYBSC4FAEL
PY-SC4FAE
external RAID controller with 2nd Level cache
external RAID controllers for SAS HDD or SSD drives
PRAID EP680e FH8GB CacheRAID 0, 1, 10, 5, 50, 6, 60
PRAID EP680e LP8GB CacheRAID 0, 1, 10, 5, 50, 6, 60
8 ports 3, 6 & 12Gb/s SAS/SATA HDD/SSD, 2x SFF8644 (external Mini-SAS HD)
supports SED (Self Encrypting Drives)
requires 1x FH or LP PCIe 4.0 x8 (int.) slot, based on LSI SAS3916
optional Flash Backup Unit (FBU)
FBU option for PRAID EP6xx: Supercap securing the power supply of the RAID controller in case of power
failure including cable with 55cm length
PYBSR4C6E
PYBSR4C6EL
PY-SR4C6E
S26361-F4042-E155S26361-F4042-L110
internal controller for PCIe SSD (NVMe SSD), no HW-RAID
internal controller for PCIe SSD (NVMe SSD)
PCIeIntel CPUNo Cache
optional Licence Activation Key for Intel VROC (VMD NVMe RAID)
No Cache
Intel VROC Upgrade Key Premium
Intel CPU
BIOS version R1.6.0 or later is required to use Intel VROC (VMD NVMe RAID)
* RAID 1 is only supported In VMware ESXi.
I
No HW-RAID
SW-RAID 0, 1, 10, 5 *
-
1x
onboard, included
PYBRLVR02PY-RLVR02
cnfgTX2550M7-20231117_IDPage 19 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
Chapter 8 - ODD optical disk drives
PRIMERGY TX2550 M7offers up to 3x 1.6” bays (located in the upper side of Tower-/ right side of Rack-server) for various ODD's and/or backup drives.
Depending on the HDD drive cage configuration there may be some or all of 1.6” bays already occupied;please find the number of availablebays in the chapter 6, "HD-cage", incl. further configuration details.
I1
12x 3.5" configuration
with 1x 9.5mm bay
I2
Configurations
with min. 1x free 1.6" bay
S26361-F3778-E1
S26361-F3778-L1
DVD-RW supermulti ultra slim
all formats, DUAL/DL, DVD-
RAM only W2K, W3K and
Linux
S26361-F3641-E6
S26361-F3641-L6
Blu-ray Triple Writer ultra slim
6x BD-RW, 8x DVD, 24x CD,
BD DL and all CD/DVD
formats
will be EOL in CQ2'24
S26361-F3266-E2
S26361-F3266-L2
DVD-ROM
DVD-ROM or CD-ROM
will be EOL in CQ2'24
S26361-F3267-E2
S26361-F3267-L2
DVD-RW supermulti SATA
all formats, DUAL/DL, DVD-
RAM only W2K, W3K and Linux
S26361-F3641-E8
S26361-F3641-L8
Blu-ray Triple Writer SATA
6x BD-RW, 8x DVD, 24x CD, BD
DL and all CD/DVD formats.
9.5mm ultra slim drive integrated
into a 5.25" bay.
9.5mm, black bezel
max. 1x per system
9.5mm, black bezel
max. 1x per system
1.6" * 5.25" black bezel
max. 1x per system
1.6" * 5.25" black bezel
max. 1x per system
9.5mm at 1.6" *5.25" black bezel
max. 1x per system
will be available in CQ2'24will be available in CQ2'24
PYBDV122PYBDR122
PY-DV122PY-DR122
DVD-ROMDVD-RW supermulti SATA
DVD-ROM or CD-ROMall formats, DUAL/DL, DVD-
RAM only W2K, W3K and Linux
9.5mm at 1.6" *5.25" black bezel
max. 1x per system
9.5mm at 1.6" *5.25" black bezel
max. 1x per system
J
cnfgTX2550M7-20231117_DPage 20 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
Chapter 9 - backup drives
With mostconfigurations the TX2550 M7 offers 3 x 1.6” bay in the accessible drives area located at the top of the Tower Server (or at the right side of the Rack) for various ODD and or backup drives.
Depending on the HDD drive configuration there may be some or all of these 1.6” bays already occupied-please find the number of availablebays and the size listed as point 3)at each of the drive
bundles. All bundles with limitations are highlighted with 2 exclamation marks in the front (e.g. "!! 1x 9.5mm ...")
J
Config. with min. 1x free 1.6" bay
SAS HBA card for Internal LTO drives
Note: In case SATA/SAS/NVMe with Raid card and PCI Riser rights(PYBPRE638/PY-PRE638/PYBPRE641/PY-PRE641/PYBPRE848/PY-PRE848/PYBPRE643/PY-
PRE643/PYBPRE645/PY-PRE645/PYBPRE851/PY-PRE851) exists, this can't be used.
SAS HBA Controller
PYBSC4FA2LPY-SC4FA
PSAS CP600i LP for LTO
requires 1x LP PCIe 4.0 x8 / for LTO drives1x
PYBSC4MA3LPY-SC4MA1
PSAS CP 2200-16i LP for LTO
requires 1x LP PCIe 4.0 x8 / for LTO drives available from 2024/031x
LTO drives (Need to select one of LTO drives togheter with SAS HBA)
LTO drives are not including tape drives. Cleaning Cartridge and Cables are included
LTO 7 tape drive (w/o tape)
6.0TB, 300MB/s, SAS 2.0, 5.25 inch/HalfHeight
LTO 8 tape drive (w/o tape)
12.0TB, 300MB/s, SAS 2.0, 5.25 inch/HalfHeight
LTO 9 tape drive (w/o tape)
18.0TB, 300MB/s, SAS 3.0, 5.25 inch/HalfHeight
1x
1x
1x
S26361-F5606-E1
S26361-F5789-E1
PYBLT911
S26361-F5606-L1
S26361-F5789-L1
PY-LT911
RDX drives
RDX drive is not including Cartridge.
RDX Drive cage (w/o cartriges)
USB 3.0, 5.25 inch / Half Height
RDX
RDX Cartrridge
RDX Cartridge 500GB
RDX Cartridge 1TB
RDX Cartridge 2TB
RDX Cartridge 4TB
1x
S26361-F3750-E4S26361-F3750-L4
-
-
-
-
-
-
-
-
S26361-F3857-L500
S26361-F3857-L600
S26361-F3857-L700
S26361-F3857-L900
K
cnfgTX2550M7-20231117_ckupPage 21 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
Chapter 10 - storage drives
SAS drives and SATA drives can be mixed, but cannot be used in one logical RAID volume.
SATA drives can be connected to the onboard Controller (max. 8x),
SAS drives require a dedicated SAS / RAID Controller
PCIe-SSDs can be connected to the onboard Controller, or require a dedicated RAID Controller or PCIe retimer/switch card.
Hard Disk Sector Format Information:
512n HDD: 512 byte sectors on the drive media.
512e (e=emulation) HDD: 4K physical sectors on the drive media with 512 byte logical configuration.
512e HDD Disk Drives: VMware 6.0 or earlier is not supported.
When using SSDs with VMware ESXi, select the SSDs that meet the endurance requirement describedin
KB2145210 below.
/kb/2145210
DWPD: Drive Writes Per Day over 5 years.
SED/FIPS are Self Encrypting Drives, and they require either a RAID controller with ®SafeStore (SED) support or an HBA and
in addition a software instance, supporting SED Key Management.
It is strongly recommended to order SafeStore (SED) RAID controller with SEDHDD or SSD devices for SafeStore (SED) functionality.
Non-SED drives and SED/FIPS drives can be mixed, but cannot be used in one logical RAID volume.
HDD Classes:
Business-Critical (BC) -SATA=Nearline SATA Enterprise Drives / 7.2Krpm,SATA 6G.
Business-Critical (BC) -SAS=Nearline SAS Enterprise Drives / 7.2Krpm,SAS 12G.
Mission-Critical (MC)=SAS 10K and SAS 15K Enterprise Drives with max. performance and reliability.
Warranty:
SSD and SATA DOM have a built-in Wear-Out indicator. In this case the warranty for such a component, as an
exception to the system warranty, is restricted to the time period until the indicator reaches the exhaust level.
K
2.5" (SFF) SAS and SATA SSD
SSD SAS 2.5" Write Intensive
(SFF) Enterprise with hot plug/hot replace tray
based on Kioxia PM7 drives
CapacityFormfactor
InterfaceEnduranceDWPDorder code E-partorder code L-part
800GB2.5" (SFF)
SAS 24Gb/sWrite Intensive10
PYBSS80NGFPY-SS80NGF
1.6TB2.5" (SFF)
SAS 24Gb/sWrite Intensive10
PYBSS16NGFPY-SS16NGF
800GB2.5" (SFF)
SAS 24Gb/sWrite Intensive10
SED FIPS available in CY24Q1
PYBSS80NGGPY-SS80NGG
1.6TB2.5" (SFF)
SAS 24Gb/sWrite Intensive10
SED FIPS available in CY24Q1
PYBSS16NGGPY-SS16NGG
max. 8x, 16x, 24x or 32x - depending on base unit & configuration
SSD SAS 2.5" Write Intensive
(SFF) Enterprise with hot plug/hot replace tray
based on Seagate Nytro3732/3750 drives
CapacityFormfactor
InterfaceEnduranceDWPDorder code E-partorder code L-part
400GB 2.5" (SFF)
SAS 12Gb/sWrite Intensive10
PYBSS40NGAPY-SS40NGA
800GB2.5" (SFF)
SAS 12Gb/sWrite Intensive10
PYBSS80NGAPY-SS80NGA
1.6TB2.5" (SFF)
SAS 12Gb/sWrite Intensive10
PYBSS16NGAPY-SS16NGA
400GB 2.5" (SFF)
SAS 12Gb/sWrite Intensive10 SED
PYBSS40NGWPY-SS40NGW
800GB2.5" (SFF)
SAS 12Gb/sWrite Intensive10 SED
PYBSS80NGWPY-SS80NGW
1.6TB2.5" (SFF)
SAS 12Gb/sWrite Intensive10 SED
PYBSS16NGWPY-SS16NGW
max. 8x, 16x, 24x or 32x - depending on base unit & configuration
SSD SAS 2.5" Mixed Use
(SFF) Enterprise with hot plug/hot replace tray
based on Kioxia PM7 drives
CapacityFormfactor
InterfaceEnduranceDWPDorder code E-partorder code L-part
1.6TB2.5" (SFF)
SAS 24Gb/sMixed Use3
PYBSS16NPMPY-SS16NPM
3.2TB2.5" (SFF)
SAS 24Gb/sMixed Use3
PYBSS32NPMPY-SS32NPM
6.4TB2.5" (SFF)
SAS 24Gb/sMixed Use3
PYBSS64NPMPY-SS64NPM
max. 8x, 16x, 24x or 32x - depending on base unit & configuration
SSD SAS 2.5" Mixed Use
(SFF) Enterprise with hot plug/hot replace tray
based on Seagate Nytro3532/3550 drives
CapacityFormfactor
InterfaceEnduranceDWPDorder code E-partorder code L-part
800GB2.5" (SFF)
SAS 12Gb/sMixed Use3
PYBSS80NPFPY-SS80NPF
1.6TB2.5" (SFF)
SAS 12Gb/sMixed Use3
PYBSS16NPFPY-SS16NPF
3.2TB2.5" (SFF)
SAS 12Gb/sMixed Use3
PYBSS32NPFPY-SS32NPF
6.4TB2.5" (SFF)
SAS 12Gb/sMixed Use3
PYBSS64NPFPY-SS64NPF
max. 8x, 16x, 24x or 32x - depending on base unit & configuration
cnfgTX2550M7-20231117__SSDPage 22 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
SSD SAS 2.5" Read Intensive
(SFF) Enterprise with hot plug/hot replace tray
based on Kioxia PM7 drives
CapacityFormfactor
InterfaceEnduranceDWPDorder code E-partorder code L-part
1.92TB 2.5" (SFF)
SAS 24Gb/sRead Intensive1
PYBSS19NNMPY-SS19NNM
3.84TB 2.5" (SFF)
SAS 24Gb/sRead Intensive1
PYBSS38NNLPY-SS38NNL
7.68TB 2.5" (SFF)
SAS 24Gb/sRead Intensive1
PYBSS76NNMPY-SS76NNM
15.36TB 2.5" (SFF)
SAS 24Gb/sRead Intensive1
PYBSS15NNLPY-SS15NNL
7.68TB 2.5" (SFF)
SAS 24Gb/sRead Intensive1
SED FIPS available in CY24Q1
PYBSS76NNNPY-SS76NNN
15.36TB 2.5" (SFF)
SAS 24Gb/sRead Intensive1
SED FIPS available in CY24Q1
PYBSS15NNMPY-SS15NNM
max. 8x, 16x, 24x or 32x - depending on base unit & configuration
will be available in CQ4'23
SSD SAS 2.5" Read Intensive
(SFF) Enterprise with hot plug/hot replace tray
based on Samsung PM1653 drives
CapacityFormfactor
InterfaceEnduranceDWPDorder code E-partorder code L-part
960GB 2.5" (SFF)
SAS 24Gb/sRead Intensive1 SED
PYBSS96NNMPY-SS96NNM
1.92TB 2.5" (SFF)
SAS 24Gb/sRead Intensive1 SED
PYBSS19NNPPY-SS19NNP
3.84TB 2.5" (SFF)
SAS 24Gb/sRead Intensive1 SED
PYBSS38NNNPY-SS38NNN
7.68TB 2.5" (SFF)
SAS 24Gb/sRead Intensive1 SED
PYBSS76NNPPY-SS76NNP
15.36TB 2.5" (SFF)
SAS 24Gb/sRead Intensive1 SED
PYBSS15NNNPY-SS15NNN
This SSDs can be used as Non-SED drives, but it requires a RAID controller with SED support for using as SED drives.
max. 8x, 16x, 24x or 32x - depending on base unit & configuration
SSD SAS 2.5" Read Intensive
(SFF) Enterprise with hot plug/hot replace tray
based on Seagate Nytro3332/3350 drives
CapacityFormfactor
InterfaceEnduranceDWPDorder code E-partorder code L-part
960GB 2.5" (SFF)
SAS 12Gb/sRead Intensive1
PYBSS96NNJPY-SS96NNJ
1.92TB 2.5" (SFF)
SAS 12Gb/sRead Intensive1
PYBSS19NNHPY-SS19NNH
3.84TB 2.5" (SFF)
SAS 12Gb/sRead Intensive1
PYBSS38NNHPY-SS38NNH
7.68TB 2.5" (SFF)
SAS 12Gb/sRead Intensive1
PYBSS76NNHPY-SS76NNH
15.36TB 2.5" (SFF)
SAS 12Gb/sRead Intensive1
PYBSS15NNGPY-SS15NNG
max. 8x, 16x, 24x or 32x - depending on base unit & configuration
will be available in CQ1'24
SSD SATA 2.5" Mixed Use (SFF)
Enterprise with hot plug/hot replace tray
based on Samsung PM897a drives
CapacityFormfactor
InterfaceEnduranceDWPDorder code E-partorder code L-part
480GB2.5" (SFF)
SATA 6Gb/sMixed Use3 SED
PYBSS48NKSPY-SS48NKS
960GB2.5" (SFF)
SATA 6Gb/sMixed Use3 SED
PYBSS96NKSPY-SS96NKS
1.92TB2.5" (SFF)
SATA 6Gb/sMixed Use3 SED
PYBSS19NKSPY-SS19NKS
3.84TB2.5" (SFF)
SATA 6Gb/sMixed Use3 SED
PYBSS38NKSPY-SS38NKS
This SSDs can be used as Non-SED drives, but it requires a RAID controller with SED support for using as SED drives.
max. 8x, 16x, 24x or 32x - depending on base unit & configuration
SSD SATA 2.5" Mixed Use (SFF)
Enterprise with hot plug/hot replace tray
based on Samsung PM897 drives
CapacityFormfactor
InterfaceEnduranceDWPDorder code E-partorder code L-part
480GB2.5" (SFF)
SATA 6Gb/sMixed Use3
PYBSS48NKQPY-SS48NKQ
960GB2.5" (SFF)
SATA 6Gb/sMixed Use3
PYBSS96NKQPY-SS96NKQ
1.92TB2.5" (SFF)
SATA 6Gb/sMixed Use3
PYBSS19NKQPY-SS19NKQ
3.84TB2.5" (SFF)
SATA 6Gb/sMixed Use3
PYBSS38NKQPY-SS38NKQ
max. 8x, 16x, 24x or 32x - depending on base unit & configuration
SSD SATA 2.5" Mixed Use (SFF)
Enterprise with hot plug/hot replace tray
based on Micron 5300/5400 MAX drives
CapacityFormfactor
InterfaceEnduranceDWPDorder code E-partorder code L-part
480GB2.5" (SFF)
SATA 6Gb/sMixed Use5,0
S26361-F5776-E480S26361-F5776-L480
960GB2.5" (SFF)
SATA 6Gb/sMixed Use5,0
S26361-F5776-E960S26361-F5776-L960
1.92TB2.5" (SFF)
SATA 6Gb/sMixed Use5,0
S26361-F5776-E192S26361-F5776-L192
3.84TB2.5" (SFF)
SATA 6Gb/sMixed Use3,5
S26361-F5776-E384S26361-F5776-L384
max. 8x, 16x, 24x or 32x - depending on base unit & configuration
will be available in CQ1'24
cnfgTX2550M7-20231117__SSDPage 23 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
SSD SATA 2.5" Read Intensive (SFF)
Enterprise with hot plug/hot replace tray
based on Samsung PM893a drives
CapacityFormfactor
InterfaceEnduranceDWPDorder code E-partorder code L-part
480GB2.5" (SFF)
SATA 6Gb/sRead Intensive1,0 SED
PYBSS48NMEPY-SS48NME
960GB2.5" (SFF)
SATA 6Gb/sRead Intensive1,0 SED
PYBSS96NMEPY-SS96NME
1.92TB2.5" (SFF)
SATA 6Gb/sRead Intensive1,0 SED
PYBSS19NMEPY-SS19NME
3.84TB2.5" (SFF)
SATA 6Gb/sRead Intensive1,0 SED
PYBSS38NMEPY-SS38NME
7.68TB2.5" (SFF)
SATA 6Gb/sRead Intensive1,0 SED
PYBSS76NMEPY-SS76NME
This SSDs can be used as Non-SED drives, but it requires a RAID controller with SED support for using as SED drives.
max. 8x, 16x, 24x or 32x - depending on base unit & configuration
SSD SATA 2.5" Read Intensive (SFF)
Enterprise with hot plug/hot replace tray
based on Samsung PM893 drives
CapacityFormfactor
InterfaceEnduranceDWPDorder code E-partorder code L-part
240GB2.5" (SFF)
SATA 6Gb/sRead Intensive1,0
PYBSS24NMDPY-SS24NMD
480GB2.5" (SFF)
SATA 6Gb/sRead Intensive1,0
PYBSS48NMDPY-SS48NMD
960GB2.5" (SFF)
SATA 6Gb/sRead Intensive1,0
PYBSS96NMDPY-SS96NMD
1.92TB2.5" (SFF)
SATA 6Gb/sRead Intensive1,0
PYBSS19NMDPY-SS19NMD
3.84TB2.5" (SFF)
SATA 6Gb/sRead Intensive1,0
PYBSS38NMDPY-SS38NMD
7.68TB2.5" (SFF)
SATA 6Gb/sRead Intensive1,0
PYBSS76NMDPY-SS76NMD
max. 8x, 16x, 24x or 32x - depending on base unit & configuration
SSD SATA 2.5" Read Intensive (SFF)
Enterprise with hot plug/hot replace tray
based on Micron 5300/5400PRO drives
CapacityFormfactor
InterfaceEnduranceDWPDorder code E-partorder code L-part
240GB2.5" (SFF)
SATA 6Gb/sRead Intensive1,5
S26361-F5783-E240S26361-F5783-L240
480GB2.5" (SFF)
SATA 6Gb/sRead Intensive1,5
S26361-F5783-E480S26361-F5783-L480
960GB2.5" (SFF)
SATA 6Gb/sRead Intensive1,5
S26361-F5783-E960S26361-F5783-L960
1.92TB2.5" (SFF)
SATA 6Gb/sRead Intensive1,5
S26361-F5783-E192S26361-F5783-L192
3.84TB2.5" (SFF)
SATA 6Gb/sRead Intensive1,2
S26361-F5783-E384S26361-F5783-L384
7.68TB2.5" (SFF)
SATA 6Gb/sRead Intensive0,6
S26361-F5783-E768S26361-F5783-L768
max. 8x, 16x, 24x or 32x - depending on base unit & configuration
L1
2.5" (SFF) Hard drives
EOL, as long as stock available
HDD SAS 2.5"
15K
(SFF) Enterprise Mission Critical with hot plug/hot replace tray
CapacityRPM
InterfaceSectororder code E-partorder code L-part
300GB
15 000SAS 12Gb/s512n
S26361-F5727-E530S26361-F5727-L530
600GB
15 000SAS 12Gb/s512n
S26361-F5727-E560S26361-F5727-L560
900GB
15 000SAS 12Gb/s512n
S26361-F5531-E590S26361-F5531-L590
max. 8x, 16x, 24x or 32x - depending on base unit & configuration
HDD SAS 2.5" 10K 512n
(SFF) Enterprise Mission Critical with hot plug/hot replace tray
CapacityRPM
InterfaceSectororder code E-partorder code L-part
300GB
10 000SAS 12Gb/s512n
S26361-F5729-E130S26361-F5729-L130
600GB
10 000SAS 12Gb/s512n
S26361-F5729-E160S26361-F5729-L160
1.2TB
10 000SAS 12Gb/s512n
S26361-F5729-E112S26361-F5729-L112
300GB
10 000SAS 12Gb/s512n SED
PYBSH301EUPY-SH301EU
600GB
10 000SAS 12Gb/s512n SED
PYBSH601EUPY-SH601EU
1.2TB
10 000SAS 12Gb/s512n SED
PYBSH121EUPY-SH121EU
max. 8x, 16x, 24x or 32x - depending on base unit & configuration
HDD SAS 2.5" 10K 512e
(SFF) Enterprise Mission Critical with hot plug/hot replace tray
CapacityRPM
InterfaceSectororder code E-partorder code L-part
1.8TB
10 000SAS 12Gb/s512e
S26361-F5730-E118S26361-F5730-L118
2.4TB
10 000SAS 12Gb/s512e
S26361-F5543-E124S26361-F5543-L124
1.8TB
10 000SAS 12Gb/s512e SED
PYBSH181DUPY-SH181DU
2.4TB
10 000SAS 12Gb/s512e SED
S26361-F5582-E124S26361-F5582-L124
max. 8x, 16x, 24x or 32x - depending on base unit & configuration
EOL, as long as stock available
HDD SAS 2.5" 7.2K 512n
(SFF) Enterprise Business Critical with hot plug/hot replace tray
CapacityRPM
InterfaceSectororder code E-partorder code L-part
1TB
7 200SAS 12Gb/s512n
S26361-F5600-E100S26361-F5600-L100
2TB
7 200SAS 12Gb/s512n
S26361-F5600-E200S26361-F5600-L200
max. 8x, 16x, 24x or 32x - depending on base unit & configuration
EOL, as long as stock available
HDD SATA 2.5" 7.2K 512n
(SFF) Enterprise Business Critical with hot plug/hot replace tray
CapacityRPM
InterfaceSectororder code E-partorder code L-part
1TB
7 200SATA 6Gb/s512n
S26361-F3956-E100S26361-F3956-L100
2TB
7 200SATA 6Gb/s512n
S26361-F3956-E200S26361-F3956-L200
max. 8x, 16x, 24x or 32x - depending on base unit & configuration
L2
cnfgTX2550M7-20231117__SSDPage 24 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
L2
3.5" (LFF) SATA SSD
will be available in CQ1'24
SSD SATA 3.5" Mixed Use
(LFF) 2.5" SSD Enterprise with 3.5" hot plug/hot replace tray
based on Samsung PM897a drives
CapacityFormfactor
InterfaceEnduranceDWPDorder code E-partorder code L-part
480GB3.5" (LFF)
SATA 6Gb/sMixed Use3 SED
PYBTS48NK9PY-TS48NK9
960GB3.5" (LFF)
SATA 6Gb/sMixed Use3 SED
PYBTS96NK9PY-TS96NK9
1.92TB3.5" (LFF)
SATA 6Gb/sMixed Use3 SED
PYBTS19NK9PY-TS19NK9
3.84TB3.5" (LFF)
SATA 6Gb/sMixed Use3 SED
PYBTS38NK9PY-TS38NK9
This SSDs can be used as Non-SED drives, but it requires a RAID controller with SED support for using as SED drives.
max. 4x, 8x, or 12x - depending on base unit & configuration
SSD SATA 3.5" Mixed Use
(LFF) 2.5" SSD Enterprise with 3.5" hot plug/hot replace tray
based on Samsung PM897 drives
CapacityFormfactor
InterfaceEnduranceDWPDorder code E-partorder code L-part
480GB3.5" (LFF)
SATA 6Gb/sMixed Use3
PYBTS48NK8PY-TS48NK8
960GB3.5" (LFF)
SATA 6Gb/sMixed Use3
PYBTS96NK8PY-TS96NK8
1.92TB3.5" (LFF)
SATA 6Gb/sMixed Use3
PYBTS19NK8PY-TS19NK8
3.84TB3.5" (LFF)
SATA 6Gb/sMixed Use3
PYBTS38NK8PY-TS38NK8
max. 4x, 8x, or 12x - depending on base unit & configuration
SSD SATA 3.5" Mixed Use (LFF)
2.5" SSD Enterprise with 3.5" hot plug/hot replace tray
based on Micron 5300/5400 MAX drives
CapacityFormfactor
InterfaceEnduranceDWPDorder code E-partorder code L-part
480GB2.5" (SFF)
SATA 6Gb/sMixed Use5,0
S26361-F5775-E480S26361-F5775-L480
960GB2.5" (SFF)
SATA 6Gb/sMixed Use5,0
S26361-F5775-E960S26361-F5775-L960
1.92TB2.5" (SFF)
SATA 6Gb/sMixed Use5,0
S26361-F5775-E192S26361-F5775-L192
3.84TB2.5" (SFF)
SATA 6Gb/sMixed Use3,5
S26361-F5775-E384S26361-F5775-L384
max. 4x, 8x, or 12x - depending on base unit & configuration
will be available in CQ1'24
SSD SATA 3.5" Read Intensive (LFF)
2.5" SSD Enterprise with 3.5" hot plug/hot replace tray
based on Samsung PM893a drives
CapacityFormfactor
InterfaceEnduranceDWPDorder code E-partorder code L-part
480GB3.5" (LFF)
SATA 6Gb/sRead Intensive1,0 SED
PYBTS48NMBPY-TS48NMB
960GB3.5" (LFF)
SATA 6Gb/sRead Intensive1,0 SED
PYBTS96NMAPY-TS96NMA
1.92TB3.5" (LFF)
SATA 6Gb/sRead Intensive1,0 SED
PYBTS19NMAPY-TS19NMA
3.84TB3.5" (LFF)
SATA 6Gb/sRead Intensive1,0 SED
PYBTS38NMAPY-TS38NMA
7.68TB3.5" (LFF)
SATA 6Gb/sRead Intensive1,0 SED
PYBTS76NMAPY-TS76NMA
This SSDs can be used as Non-SED drives, but it requires a RAID controller with SED support for using as SED drives.
max. 4x, 8x, or 12x - depending on base unit & configuration
SSD SATA 3.5" Read Intensive (LFF)
2.5" SSD Enterprise with 3.5" hot plug/hot replace tray
based on Samsung PM893 drives
CapacityFormfactor
InterfaceEnduranceDWPDorder code E-partorder code L-part
240GB3.5" (LFF)
SATA 6Gb/sRead Intensive1,0
PYBTS24NM9PY-TS24NM9
480GB3.5" (LFF)
SATA 6Gb/sRead Intensive1,0
PYBTS48NM9PY-TS48NM9
960GB3.5" (LFF)
SATA 6Gb/sRead Intensive1,0
PYBTS96NM9PY-TS96NM9
1.92TB3.5" (LFF)
SATA 6Gb/sRead Intensive1,0
PYBTS19NM9PY-TS19NM9
3.84TB3.5" (LFF)
SATA 6Gb/sRead Intensive1,0
PYBTS38NM9PY-TS38NM9
7.68TB3.5" (LFF)
SATA 6Gb/sRead Intensive1,0
PYBTS76NM9PY-TS76NM9
max. 4x, 8x, or 12x - depending on base unit & configuration
SSD SATA 3.5" Read Intensive (LFF)
2.5" SSD Enterprise with 3.5" hot plug/hot replace tray
based on Micron 5300/5400 PRO drives
CapacityFormfactor
InterfaceEnduranceDWPDorder code E-partorder code L-part
240GB2.5" (SFF)
SATA 6Gb/sRead Intensive1,5
S26361-F5782-E240S26361-F5782-L240
480GB2.5" (SFF)
SATA 6Gb/sRead Intensive1,5
S26361-F5782-E480S26361-F5782-L480
960GB2.5" (SFF)
SATA 6Gb/sRead Intensive1,5
S26361-F5782-E960S26361-F5782-L960
1.92TB2.5" (SFF)
SATA 6Gb/sRead Intensive1,5
S26361-F5782-E192S26361-F5782-L192
3.84TB2.5" (SFF)
SATA 6Gb/sRead Intensive1,2
S26361-F5782-E384S26361-F5782-L384
7.68TB2.5" (SFF)
SATA 6Gb/sRead Intensive0,6
S26361-F5782-E768S26361-F5782-L768
max. 4x, 8x, or 12x - depending on base unit & configuration
cnfgTX2550M7-20231117__SSDPage 25 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
3.5" (LFF) Hard drives
EOL, as long as stock available
HDD SAS 3.5"
15K
(LFF) 2.5" HDD Enterprise Mission Critical with 3.5" hot plug/hot replace tray
CapacityRPM
InterfaceSectororder code E-partorder code L-part
300GB
15 000SAS 12Gb/s512n
S26361-F5726-E530S26361-F5726-L530
600GB
15 000SAS 12Gb/s512n
S26361-F5726-E560S26361-F5726-L560
900GB
15 000SAS 12Gb/s512n
S26361-F5532-E590S26361-F5532-L590
max. 4x, 8x, or 12x - depending on base unit & configuration
HDD SAS 3.5"
10K 512n
(LFF) 2.5" HDD Enterprise Mission Critical with 3.5" hot plug/hot replace tray
CapacityRPM
InterfaceSectororder code E-partorder code L-part
300GB
10 000SAS 12Gb/s512n
S26361-F5728-E130S26361-F5728-L130
600GB
10 000SAS 12Gb/s512n
S26361-F5728-E160S26361-F5728-L160
1.2TB
10 000SAS 12Gb/s512n
S26361-F5728-E112S26361-F5728-L112
max. 4x, 8x, or 12x - depending on base unit & configuration
HDD SAS 3.5"
10K 512e
(LFF) 2.5" HDD Enterprise Mission Critical with 3.5" hot plug/hot replace tray
CapacityRPM
InterfaceSectororder code E-partorder code L-part
1.8TB
10 000SAS 12Gb/s512e
S26361-F5731-E118S26361-F5731-L118
2.4TB
10 000SAS 12Gb/s512e
S26361-F5569-E124S26361-F5569-L124
max. 4x, 8x, or 12x - depending on base unit & configuration
HDD SAS 3.5" 7.2K 512n
(LFF) Enterprise Business critical with hot plug/hot replace tray
CapacityRPM
InterfaceSectororder code E-partorder code L-part
2TB
7 200SAS 12Gb/s512n
PYBCH2T7G4PY-CH2T7G4
4TB
7 200SAS 12Gb/s512n
PYBCH4T7G4PY-CH4T7G4
max. 4x, 8x, or 12x - depending on base unit & configuration
HDD SAS 3.5" 7.2K 512e
(LFF) Enterprise Business Critical with hot plug/hot replace tray
CapacityRPM
InterfaceSectororder code E-partorder code L-part
6TB
7 200SAS 12Gb/s512e
PYBCH6T7B9PY-CH6T7B9
8TB
7 200SAS 12Gb/s512e
S26361-F5635-E800S26361-F5635-L800
12TB
7 200SAS 12Gb/s512e
PYBCHCT7B7PY-CHCT7B7
14TB
7 200SAS 12Gb/s512e
PYBCHET7B6PY-CHET7B6
16TB
7 200SAS 12Gb/s512e
S26361-F5571-E160S26361-F5571-L160
18TB
7 200SAS 12Gb/s512e
PYBCHJT7B2PY-CHJT7B2
20TB
7 200SAS 12Gb/s512eWiil be avairable in CQ1 2024
PYBCHLT7BPY-CHLT7B
6TB
7 200SAS 12Gb/s512e SED
PYBCH6T7BUPY-CH6T7BU
8TB
7 200SAS 12Gb/s512e SED
S26361-F5584-E800S26361-F5584-L800
12TB
7 200SAS 12Gb/s512e SED
PYBCHCT7BWPY-CHCT7BW
14TB
7 200SAS 12Gb/s512e SED
PYBCHET7BVPY-CHET7BV
16TB
7 200SAS 12Gb/s512e SED
S26361-F5624-E160S26361-F5624-L160
18TB
7 200SAS 12Gb/s512e SED
PYBCHJT7BTPY-CHJT7BT
20TB
7 200SAS 12Gb/s512e
FIPS Wiil be avairable in CQ1 2024
PYBCHLT7BSPY-CHLT7BS
max. 4x, 8x, or 12x - depending on base unit & configuration
HDD SATA 3.5" 7.2K 512n
(LFF) Enterprise Business Critical with hot plug/hot replace tray
CapacityRPM
InterfaceSectororder code E-partorder code L-part
1TB
7 200SATA 6Gb/s512n
PYBBH1T7B9PY-BH1T7B9
2TB
7 200SATA 6Gb/s512n
PYBBH2T7B9PY-BH2T7B9
4TB
7 200SATA 6Gb/s512n
PYBBH4T7B9PY-BH4T7B9
max. 4x, 8x, or 12x - depending on base unit & configuration
HDD SATA 3.5" 7.2K 512e
(LFF) Enterprise Business Critical with hot plug/hot replace tray
CapacityRPM
InterfaceSectororder code E-partorder code L-part
6TB
7 200SATA 6Gb/s512e
PYBBH6T7E9PY-BH6T7E9
8TB
7 200SATA 6Gb/s512e
S26361-F5638-E800S26361-F5638-L800
12TB
7 200SATA 6Gb/s512e
PYBBHCT7E4PY-BHCT7E4
14TB
7 200SATA 6Gb/s512e
PYBBHET7E4PY-BHET7E4
16TB
7 200SATA 6Gb/s512e
S26361-F3904-E160S26361-F3904-L160
18TB
7 200SATA 6Gb/s512e
PYBBHJT7E2PY-BHJT7E2
max. 4x, 8x, or 12x - depending on base unit & configuration
L3
cnfgTX2550M7-20231117__SSDPage 26 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
L3
M.2 SATA SSD
M.2 drive for VMware ESXi and for other OSs cannot be mixed
M.2 SATA and M.2 PCIe drive cannot be mixed
SSD SATA M.2 drive for booting, non hot-plug, for VMware ESXi
based on Micron 5300/5400 PRO drives
CapacityFormfactor
InterfaceCategoryorder code E-partorder code L-part
240GBM.2
SATA 6Gb/sBoot
S26361-F5816-E240S26361-F5816-L240
M.2 drive is designed for use as a VMware ESXi boot drive.
max. 1x per Server; in case M.2 drive is installed in connector located on Motherboard (please see folder "description"). VMware ESXi is only supported.
2x M.2 drives required; in case M.2 drives are used with PDUAL CP100 or CP300.
SSD SATA M.2 drive for booting, non hot-plug
based on Micron 5300/5400 PRO drives (960GB is 5400 only)
CapacityFormfactor
InterfaceDWPDCategoryorder code E-partorder code L-part
240GBM.2
SATA 6Gb/s1,5Boot
S26361-F5787-E240S26361-F5787-L240
480GBM.2
SATA 6Gb/s1,5Boot
S26361-F5787-E480S26361-F5787-L480
960GBM.2 2280
SATA 6Gb/s1,5Boot
PYBMF96YNPY-MF96YN
M.2 drive is designed for use as a boot drive with the Endurance Spec. above.
2x M.2 drive for any Hypervisor by the onboard chipset Software RAID is not supported.
max. 2x per Server; in case M.2 drive is installed in connector located on Motherboard (please see folder "description"). VMware is not supported.
2x M.2 drives required; in case M.2 drives are used with PDUAL CP100 or CP300.
SSD PCIe M.2 drive for booting, non hot-plug
based on Micron 7450 PRO drives
CapacityFormfactor
InterfaceDWPDCategoryorder code E-partorder code L-part
480GBM.2 2280
PCIe4.0 x40,9Boot
PYBBS48PEAPY-BS48PEA
960GBM.2 2280
PCIe4.0 x40,9Boot
PYBBS96PEAPY-BS96PEA
M.2 drive is designed for use as a boot drive with the Endurance Spec. above.
max. 2x per Server; connector located on Motherboard (please see folder "description"). 2x M.2 drives require Intel VROC Upgrade Key Premium(PYBRLVR02).
2x M.2 drives required; in case M.2 drives are used with PDUAL CP300.
Dual M.2
PDUAL CP100, PDUAL CP300 and M.2 drive on Motherboard cannot be mixed
PDUAL CP100, dual M.2 for booting, non hot-plug
CapacityFormfactor
InterfaceCategoryorder code E-partorder code L-part
n/aAIC
PCIeBootFH
PYBDMCP24
n/aAIC
PCIeBootLP
PYBDMCP24L
PY-DMCP24
PDUAL CP100 is a carrier of 2x SSD SATA M.2 drives, which offers RAID1 with the 2x SSD M.2 drives.
PDUAL CP100 is designed for use as a hardware-mirrored (RAID1) boot device for Hypervisor, which cannot be supported by M.2 via the onboard chipset Software RAID.
Supported RAID level : RAID1 only, 2x same type of SSD M.2 drives need to be ordered separately.
Supported M.2 drives : SSD SATA M.2 240GB/480GB/960GB or 240GB for VMware ESXi. (S26361-F5787- E240/L240/E480/L480, PY*MF96YN or S26361-F5816-E240/L240)
max. 1x per Server, requires 2x SSD SATA M.2 drives.
PDUAL CP100, PDUAL CP300 and M.2 drive on Motherboard cannot be mixed
PDUAL CP300, dual M.2 for booting, non hot-plug
available from 2024/02
CapacityFormfactor
InterfaceCategoryorder code E-partorder code L-part
n/aAIC
PCIeBootFH
PYBDMCP35
n/aAIC
PCIeBootLP
PYBDMCP35L
PY-DMCP35
PDUAL CP300 is a carrier of 2x SSD SATA or PCIe M.2 drives, which offers RAID1 with the 2x SSD M.2 drives.
PDUAL CP300 is designed for use as a hardware-mirrored (RAID1) boot device for Hypervisor, which cannot be supported by M.2 via the onboard chipset Software RAID.
Supported RAID levels : RAID1 and 0 (optional), 2x same type of SSD M.2 drives need to be ordered separately.
Supported M.2 drives : SSD SATA M.2 240GB/480GB/960GB or 240GB for VMware ESXi. (S26361-F5787- E240/L240/E480/L480, PY*MF96YN or S26361-F5816-E240/L240) or
SSD PCIe M.2 480GB/960GB. (PY*BS48PEA/PY*BS96PEA)
max. 1x per Server, requires 2x SSD M.2 drives.
cnfgTX2550M7-20231117__SSDPage 27 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
2.5" (SFF) PCIe-SSD
hot plug support : supported with VMD
PCIe-SSD 2.5" P5800X
(SFF) Enterprise with hot plug/hot replace tray
based on Intel P5800X drives
CapacityFormfactor
InterfaceEnduranceDWPDorder code E-partorder code L-part
400GB2.5" (SFF)
PCIe4.0 x4Write Intensive100
PYBBS40PFPY-BS40PF
800GB2.5" (SFF)
PCIe4.0 x4Write Intensive100
PYBBS80PFPY-BS80PF
1.6TB2.5" (SFF)
PCIe4.0 x4Write Intensive100
PYBBS16PFPY-BS16PF
max. 8x (4x per CPU) - depending on base unit & configuration
limitation : can not support VROC so farwill be available in CQ4'23
PCIe-SSD 2.5" Mixed Use
(SFF) Enterprise with hot plug/hot replace tray
based on Kioxia CM7-V drives
CapacityFormfactor
InterfaceEnduranceDWPDorder code E-partorder code L-part
1.6TB2.5" (SFF)
PCIe5.0 x4Mixed Use3
PYBBS16PDBPY-BS16PDB
3.2TB2.5" (SFF)
PCIe5.0 x4Mixed Use3
PYBBS32PDBPY-BS32PDB
6.4TB2.5" (SFF)
PCIe5.0 x4Mixed Use3
PYBBS64PDBPY-BS64PDB
12.8TB2.5" (SFF)
PCIe5.0 x4Mixed Use3
PYBBS12PDBPY-BS12PDB
max. 8x (4x per CPU) - depending on base unit & configuration
EOL, as long as stock available
PCIe-SSD 2.5" Mixed Use
(SFF) Enterprise with hot plug/hot replace tray
based on Kioxia CM6-V drives
CapacityFormfactor
InterfaceEnduranceDWPDorder code E-partorder code L-part
1.6TB2.5" (SFF)
PCIe4.0 x4Mixed Use3
PYBBS16PD6PY-BS16PD6
3.2TB2.5" (SFF)
PCIe4.0 x4Mixed Use3
PYBBS32PD6PY-BS32PD6
6.4TB2.5" (SFF)
PCIe4.0 x4Mixed Use3
PYBBS64PD6PY-BS64PD6
12.8TB2.5" (SFF)
PCIe4.0 x4Mixed Use3
PYBBS12PD6PY-BS12PD6
max. 8x (4x per CPU) - depending on base unit & configuration
limitation : can not support VROC so farwill be available in CQ4'23
PCIe-SSD 2.5" Read Intensive
(SFF) Enterprise with hot plug/hot replace tray
based on Kioxia CM7-R drives
CapacityFormfactor
InterfaceEnduranceDWPDorder code E-partorder code L-part
1.92TB2.5" (SFF)
PCIe5.0 x4Read Intensive1
PYBBS19PEAPY-BS19PEA
3.84TB2.5" (SFF)
PCIe5.0 x4Read Intensive1
PYBBS38PEAPY-BS38PEA
7.68TB2.5" (SFF)
PCIe5.0 x4Read Intensive1
PYBBS76PEAPY-BS76PEA
15.36TB2.5" (SFF)
PCIe5.0 x4Read Intensive1
PYBBS15PEBPY-BS15PEB
max. 8x (4x per CPU) - depending on base unit & configuration
EOL, as long as stock available
PCIe-SSD 2.5" Read Intensive
(SFF) Enterprise with hot plug/hot replace tray
based on Kioxia CM6-R drives
CapacityFormfactor
InterfaceEnduranceDWPDorder code E-partorder code L-part
960GB2.5" (SFF)
PCIe4.0 x4Read Intensive1
PYBBS96PE6PY-BS96PE6
1.92TB2.5" (SFF)
PCIe4.0 x4Read Intensive1
PYBBS19PE6PY-BS19PE6
3.84TB2.5" (SFF)
PCIe4.0 x4Read Intensive1
PYBBS38PE6PY-BS38PE6
7.68TB2.5" (SFF)
PCIe4.0 x4Read Intensive1
PYBBS76PE6PY-BS76PE6
15.36TB2.5" (SFF)
PCIe4.0 x4Read Intensive1
PYBBS15PE6PY-BS15PE6
max. 8x (4x per CPU) - depending on base unit & configuration
M
cnfgTX2550M7-20231117__SSDPage 28 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
M
Chapter 11 - LAN Components
FH PCI card requires FH PCI riser. Please refer to ''Chapter 14 - PCI Riser'.
Broadcom 1GbE BEASE-T for PCIe
PLAN CP BCM5719-4P 4X 1000BASE-T PCIe LP6x
PLAN CP BCM5719-4P 4X 1000BASE-T PCIe FH8x
Broadcom, 1GTx4port
PYBLA284L
PYBLA284
PY-LA284
max. 10 adapters per system
Intel 1GbE BASE-T for PCIe
PLAN CP 2x1Gbit Cu Intel I350-T2 LP *1
6x
Intel, 1GTx2port
S26361-F4610-E202S26361-F4610-L502
PLAN CP 4x1Gbit Cu Intel I350-T4 LP6x
Intel, 1GTx4port
S26361-F4610-E204
S26361-F4610-L504
max. 6 adapters per system
*1 Will be available from 2Q, CY2024
Broadcom 10GbE BEASE-T for PCIe
PLAN EP P210TP 2X 10GBASE-T PCIe LP4x
PLAN EP P210TP 2X 10GBASE-T PCIe FH6x
Broadcom, 10GTx2port
PYBLA3K2L
PYBLA3K2
PY-LA3K2
max. 6x adapters per system (must not exceed this number with P210TP and P210P in total and LP cannnot be put on slot#3, slot#10)
Intel 10GbE BASE-T for PCIe
PLAN EP X710-T2L 2X 10GBASE-T LP6xPYBLA342L
PLAN EP X710-T2L 2X 10GBASE-T FH8x
Intel, 10GTx2port
PYBLA342
PY-LA342
PLAN EP X710-T4L 4X 10GBASE-T LP6xPYBLA344L
PLAN EP X710-T4L 4X 10GBASE-T FH8x
Intel, 10GTx4port
PYBLA344
PY-LA344
max. 10x adapters per system
Broadcom 10GbE for PCIe
Each cage consumes 1x optical SFP+ transceiver per port.
Dual rate 10G/1G support requires 10G/1G Dual Rate SFP+ Optical Transceiver Modules.
All ports on this card can install the same Parts Number of optical module.
PLAN EP P210P 2x10Gb SFP PCIe LP4x
PYBLA3J2L
PLAN EP P210P 2x10Gb SFP PCIe FH6x
Broadcom, 10Gx2port
PYBLA3J2
PY-LA3J2
Optional, 10Gb SFP+ optical transceiver module, select one per cage
SFP+ Optical Transceiver 10G Single Rate SR
2x
Finisar, 10G SR SFP+
S26361-F3986-E3S26361-F3986-L3
SFP+ Optical Transceiver 10G/1G Dual Rate
SR
2x
Intel, 1G/10G SR SFP+
S26361-F3986-E5S26361-F3986-L5
SFP+ Optical Transceiver 10G/1G Dual Rate LR
2x
Intel, 1G/10G LR SFP+
S26361-F3986-E6S26361-F3986-L6
max. 1x per port
max. 6x adapters per system (must not exceed this number with P210TP and P210P in total and LP cannnot be put on slot#3, slot#10)
Intel 10GbE for PCIe
Each cage consumes 1x optical SFP+ transceiver per port.
Dual rate 10G/1G support requires 10G/1G Dual Rate SFP+ Optical Transceiver Modules.
All ports on this card can install the same Parts Number of optical module.
PLAN EP X710-DA2 2x10Gb SFP+ LP6xS26361-F3640-E202
PLAN EP X710-DA2 2x10Gb SFP+ FH8x
Intel, 10Gx2port
S26361-F3640-E2
S26361-F3640-L502
PLAN EP X710-DA4 4x10Gb SFP+ LP6xS26361-F3640-E204
PLAN EP X710-DA4 4x10Gb SFP+ FH8x
Intel, 10Gx4port
S26361-F3640-E4
S26361-F3640-L504
Optional, 10Gb SFP+ optical transceiver module, select one per cage
SFP+ Optical Transceiver 10G Single Rate SR
4x
Finisar, 10G SR SFP+
S26361-F3986-E3S26361-F3986-L3
SFP+ Optical Transceiver 10G/1G Dual Rate
SR
4x
Intel, 1G/10G SR SFP+
S26361-F3986-E5S26361-F3986-L5
SFP+ Optical Transceiver 10G/1G Dual Rate LR
4x
Intel, 1G/10G LR SFP+
S26361-F3986-E6S26361-F3986-L6
max. 1x per port
max. 10x adapters per system
Broadcom 25GbE for PCIe
Each cage consumes 1x optical SFP28.
All ports on this card can install the same Parts Number of optical module.
10G SFP BTO is not available for 25G cards, please select L parts.
PLAN EP P225P 25Gb 2p SFP28 PCIe LP *1
6x
PYBLA3H2L
PLAN EP P225P 25Gb 2p SFP28 PCIe FH *1
8x
Broadcom, 25Gx2port
PYBLA3H2
PY-LA3H2
Optional, 25Gb SFP28 optical transceiver module, select one per cage
SFP28 25G SR E25GSFP28SRX LC
2x
Intel, 25G SR SFP28PYBSFPS56PY-SFPS56
max. 1x per port
Optional, 10Gb SFP+ optical transceiver module, select one per cage
SFP+ Optical Transceiver 10G/1G Dual Rate
SR
2x
Intel, 1G/10G SR SFP+
S26361-F3986-E5S26361-F3986-L5
SFP+ Optical Transceiver 10G/1G Dual Rate LR
2x
Intel, 1G/10G LR SFP+
S26361-F3986-E6S26361-F3986-L6
max. 1x per port
max. 10x adapters per system
*1 Will be available from 1Q, CY2024
cnfgTX2550M7-20231117_NPage 29 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
NVIDIA 25GbE for PCIe
Each cage consumes 1x optical SFP28.
All ports on this card can install the same Parts Number of optical module.
10G SFP BTO is not available for 25G cards, please select L parts.
Ethernet Network Adapters
PLAN EP MCX6-LX 25Gb 2p SFP28 PCIe LP *1
6x
PYBLA402L4
PLAN EP MCX6-LX 25Gb 2p SFP28 PCIe FH *1
8x
NVIDIA, 25Gx2port
PYBLA4024
PY-LA4024
Optional, 25Gb SFP28 optical transceiver module, select one per cage
SFP28 25G SR E25GSFP28SRX LC
2x
Intel, 25G SR SFP28PYBSFPS56PY-SFPS56
SFP28 Optical Transceiver 25G SR MMA2P00-
AS LC
2x
NVIDIA, 25G SR SFP28S26361-F4054-E701S26361-F4054-L701
max. 1x per port
Optional, 10Gb SFP+ optical transceiver module, select one per cage
SFP+ Optical Transceiver 10G/1G Dual Rate
SR
2x
Intel, 1G/10G SR SFP+
S26361-F3986-E5S26361-F3986-L5
SFP+ Optical Transceiver 10G/1G Dual Rate LR
2x
Intel, 1G/10G LR SFP+
S26361-F3986-E6S26361-F3986-L6
max. 1x per port
max. 10x adapters per system
*1 Will be available from 1Q, CY2024
Intel 25GbE for PCIe
Each cage consumes 1x optical SFP28.
All ports on this card can install the same Parts Number of optical module.
10G SFP BTO is not available for 25G cards, please select L parts.
PLAN EP E810-XXVDA2 2X 25G SFP28 LP6x
PLAN EP E810-XXVDA2 2X 25G SFP28 FH8x
Intel, 25Gx2port
PYBLA402L
PYBLA402
PY-LA402
PLAN EP E810-XXVDA4 4X 25G SFP28 LP
6x
Intel, 25Gx4port
PYBLA404L
PY-LA404
Optional, 25Gb SFP28 optical transceiver module, select one per cage
SFP28 25G SR E25GSFP28SRX LC
4x
Intel, 25G SR SFP28
PYBSFPS56PY-SFPS56
max. 1x per port
Optional, 10Gb SFP+ optical transceiver module, select one per cage
SFP+ Optical Transceiver 10G/1G Dual Rate
SR
4x
Intel, 1G/10G SR SFP+
S26361-F3986-E5S26361-F3986-L5
SFP+ Optical Transceiver 10G/1G Dual Rate LR
4x
Intel, 1G/10G LR SFP+
S26361-F3986-E6S26361-F3986-L6
max. 1x per port
max. 10x adapters per system(E810-XXVDA2) / max. 6x adapters per system(E810-XXVDA4)
Broadcom 100GbE for PCIe
Each cage consumes 1x optical QSFP28
All ports on this card can install the same Parts Number of optical module.
PLAN EP P2100G 100Gb 2p QSFP56 PCIe LP *16xBroadcom, 100Gx2portPYBLA442LPY-LA442
PLAN EP P2100G 100Gb 2p QSFP56 PCIe FH *14xBroadcom, 100Gx2portPYBLA442PY-LA442
Optional, 100Gb QSFP28 Optical Transceiver module
QSFP28 100G SR4 E100GQSFP28SRX MPO
2x
Intel, 100G SR4 QSFP28PYBSFPS54PY-SFPS54
QSFP28 100G SR4 MPO 850nm 100m
MMA1B00-C100D
2x
NVIDIA, 100G SR4 QSFP28S26361-F4052-E701S26361-F4052-L701
max. 1x per port
max. 6x adapters per system
*1 Will be available from 1Q, CY2024
Intel 100GbE for PCIe
Each cage consumes 1x optical QSFP28.
The QSFP will not ship on the card because it will interfere with the shipping box.
All ports on this card can install the same Parts Number of optical module.
PLAN EP E810-CQDA2 2X 100G QSFP28 LP6x
Intel, 100Gx2portPYBLA432LPY-LA432
Optional, 100Gb QSFP28 Optical Transceiver module
QSFP28 100G SR4 E100GQSFP28SRX MPO
2x
Intel, 100G SR4 QSFP28PYBSFPS54PY-SFPS54
max. 1x per port
max. 6x adapters per system
NVIDIA 100GbE for PCIe
Each cage consumes 1x optical QSFP28
The QSFP will not ship on the card because it will interfere with the shipping box.
All ports on this card can install the same Parts Number of optical module.
PLAN EP MCX6-DX 2X 100G QSFP28 LP6x
NVIDIA, 100Gx2portPYBLA412LPY-LA412
Optional, 100Gb QSFP28 Optical Transceiver module
QSFP28 100G SR4 MPO 850nm 100m
MMA1B00-C100D
2x
NVIDIA, 100G SR4 QSFP28
S26361-F4052-E701S26361-F4052-L701
max. 1x per port
max. 6x adapters per system
N
Network cables for later upgrade
O
cnfgTX2550M7-20231117_NPage 30 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
Chapter 12 - Fibre Channel Controller
O
FH PCIe card requires FH PCIe riser card. Please refer to ''Chapter 14 - PCI riser card'.
max number of some controllers can vary with base units with 6x card slots
64G Fibre Channel adapters with LC interface for 50µm optical cables (OM4 or OM3)
PFC EP LPe36000 1X 32GFC PCIe v4 LP6x
Broadcom, 64GFCx1port
PFC EP LPe36000 1X 32GFC PCIe FH8x
PFC EP LPe36002 2X 32GFC PCIe v4 LP6x
Broadcom, 64GFCx2port
PFC EP LPe36002 2X 32GFC PCIe v4 FH8x
6x
PFC EP QLE2870 1X 32GFC PCIe v4 LP
Marvell, 64GFCx1port
PFC EP QLE2870 1X 32GFC PCIe v4 FH 8x
PFC EP QLE2872 2X 32GFC PCIe v4 LP 6x
Marvell, 64GFCx2port
PFC EP QLE2872 2X 32GFC PCIe v4 FH 8x
32G Fibre Channel adapters with LC interface for 50µm optical cables (OM4 or OM3)
PFC EP LPe35000 1X 32GFC PCIe v4 LP6x
Broadcom, 32GFCx1port
PFC EP LPe35000 1X 32GFC PCIe v4 FH8x
PFC EP LPe35002 2X 32GFC PCIe v4 LP6x
Broadcom, 32GFCx2port
PFC EP LPe35002 2X 32GFC PCIe v4 FH8x
PFC EP QLE2770 1X 32GFC PCIe v4 LP6x
Marvell, 32GFCx1port
PFC EP QLE2770 1X 32GFC PCIe v4 FH8x
PFC EP QLE2772 2X 32GFC PCIe v4 LP6x
Marvell, 32GFCx2port
PFC EP QLE2772 2X 32GFC PCIe v4 FH 8x
16G Fibre Channel adapters with LC interface for 50µm optical cables (OM4 or OM3)
PFC EP LPe31000 1x 16Gb LP6x
Broadcom, 16GFCx1port
PFC EP LPe31000 1x 16Gb FH8x
PFC EP LPe31002 2x 16Gb LP6x
Broadcom, 16GFCx2port
PFC EP LPe31002 2x 16Gb FH8x
PFC EP QLE2690 1x 16Gb LP6x
Marvell, 16GFCx1port
PFC EP QLE2690 1x 16Gb FH8x
PFC EP QLE2692 2x 16Gb LP6x
Marvell, 16GFCx2port
PFC EP QLE2692 2x 16Gb FH8x
max. 10 adapters per system
PYBFC441L
PYBFC441
PYBFC442L
PYBFC442
PYBFC431L
PYBFC431
PYBFC432L
PYBFC432
PYBFC421L
PYBFC421
PYBFC422L
PYBFC422
PYBFC411L
PYBFC411
PYBFC412L
PYBFC412
S26361-F5596-E201
S26361-F5596-E1
S26361-F5596-E202
S26361-F5596-E2
S26361-F5580-E201
S26361-F5580-E1
S26361-F5580-E202
S26361-F5580-E2
PY-FC441
PY-FC442
PY-FC431
PY-FC432
PY-FC421
PY-FC422
PY-FC411
PY-FC412
S26361-F5596-L501
S26361-F5596-L502
S26361-F5580-L501
S26361-F5580-L502
Chapter 13 - Infiniband Controllers
Infinibandand Omni path controller will not be released.
P
cnfgTX2550M7-20231117__IBPage 31 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
Chapter 14 - PCI riser card
PCI riser card configuration
Standard Model only(PYT2557TAN/PYT2557TBN/PYT2557TCN
/PYT2557R3N/PYT2557R2N/PYT2557RAN)
6x PCIe slots are on board, with optional PCIe riser card up to 10x PCIe slots are available.
You can choose between 6 different PCI riser card (Options a – f), depending on the selected PCIe card or GPGPU.
Please refer to the tables below for more details and for the installation rules.
Required 'Configuration Thermal Design 30°C(CTD30)[PYBETA1]'
P
Full height PCIe card
A100, A30, A16, L40
or x16 PCIe card
is selected
Details of each PCIe riser card option (a – f) are described on the following pages
T400 4GB, A2, L4,
RTX A6000, RTX
A4500, RTX 6000
or x16 PCIe card
is selected
T400 4GB
or x8 PCIe card
is selected
Option c)
Full height 4slot PCIe riser card
(x8 Gen4)
A100, A30, A16, L40,
,H100
or x16 PCIe card
is selected
T400 4GB, A2, L4,
RTX A6000, RTX
A4500, RTX 6000
or x16 PCIe card
is selected
T400 4GB
or x8 PCIe card
is selected
Option f)
Full height 4slot PCIe riser card
(x8 Gen5)
with retimer
Option a)
Full height 2slot PCIe riser card
(x16 Gen4)
with PCIe support bracket
Option d)
Full height 2slot PCIe riser card
(x16 Gen5)
with PCIe support bracket
with retimer
Option b)
Full height 2slot PCIe riser card
(x16 Gen4)
without PCIe support bracket
Option e)
Full height 2slot PCIe riser card
(x16 Gen5)
without PCIe support bracket
with retimer
Q
Possible configurations with each PCIe riser card option
*Support brackets are required for the cooling of passively cooled FH GPUs.
cnfgTX2550M7-20231117_I_riser_cardPage 32 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
Option a) Full height 2slot PCIe riser card (x16 Gen4) with PCIe support bracket
If the below 2 options are selected, 6x PCIe slots (LP/ x16) change to 2x PCIe slots (LP/ x16) + 4x PCIe slots (FH/ x16).
PCIe cards and double width GPGPUs can be supported on 4x PCIe slots (FH/ x16).
One full height GPGPU can be installed on 1x PCIe slot (FH/ x16).
Support brackets are required for the cooling of passively cooled FH GPUs.“
A100, A30, A16, L40 and / or FH PCIe card is selected
Full height 2slot PCIe riser card right (CPU 1) with PCIe support bracket
PYBPRE638 / PY-PRE638
x16 Gen4 PCIe riser card
Note:
With this card, 3x PCIe slots (LP/ x16) change to 1x PCIe slots (LP/ x16) + 2x PCIe slots (FH/ x16).
Please refer to ‘Chapter 5 – Graphics cards’ for more details about the supported GPGPUs’.
Please refer to chapter ‘Thermal’ for more details about limitations’.
Full height 2slot PCIe riser card left (CPU 2) with PCIe support bracket
PYBPRE639 / PY-PRE639
x16 Gen4 PCIe riser card
Note:
2nd CPU is needed.
With this card, 3x PCIe slots (LP/ x16) change to 1x PCIe slots (LP/ x16) + 2x PCIe slots (FH/ x16).
Please refer to ‘Chapter 5 – Graphics cards’ for more details about the supported GPGPUs'.
Option b) Full height 2slot PCIe riser cards (x16 Gen4) without PCIe support bracket
If the below 2 options are selected, 6x PCIe slots (LP/ x16) change to 2x PCIe slots (LP/ x16) + 4x PCIe slots (FH/ x16).
PCIe cards and double width GPGPUs can be supported on 4x PCIe slots (FH/ x16).
One full height GPGPU can be installed on 1x PCIe slot (FH/ x16).
T400 4GB, A2, L4, RTX A6000, RTX A4500, RTX 6000 and / or FH PCIe card is selected
Full height 2slot PCIe riser card right (CPU 1) without PCIe support bracket
PYBPRE641 / PY-PRE641
x16 Gen4 PCIe riser card
Note:
With this card, 3x PCIe slots (LP/ x16) change to 1x PCIe slots (LP/ x16) + 2x PCIe slots (FH/ x16).
Please refer to ‘Chapter 5 – Graphics cards’ for more details about the supported GPGPUs’.
Please refer to chapter ‘Thermal’ for more details about limitations’.
Full height 2slot PCIe riser card left (CPU 2) without PCIe support bracket
PYBPRE642 / PY-PRE642
x16 Gen4 PCI Riser
Note:
2nd CPU is needed.
With this card, 3x PCIe slots (LP/ x16) change to 1x PCIe slots (LP/ x16) + 2x PCIe slots (FH/ x16).
Please refer to ‘Chapter 5 – Graphics cards’ for more details about the supported GPGPUs'.
Option c) Full height 4slot PCIe riser card (x8 Gen4)
If the below 2 options are selected, 6x PCIe slots (LP/ x16) change to 2x PCIe slots (LP/ x16) + 8x PCIe slots (FH/ x8).
GPGPU(Double height) cannot be supported.
T400 4GB and / or FH PCIe card is selected
Full height 4slot PCIe riser card right (CPU1)
PYBPRE848 / PY-PRE848
x8 Gen4 PCIe riser card
Note:
With this card, 3x PCIe slots (LP/ x16) change to 1x PCIe slots (LP/ x16) + 4x PCIe slots (FH/ x8).
Please refer to ‘Chapter 5 – Graphics cards’ for more details about the supported GPGPUs’.
Please refer to chapter ‘Thermal’ for more details about limitations’.
Full height 4slot PCIe riser card left (CPU2)
PYBPRE849 /PY-PRE849
x8 Gen4 PCI Riser
Note:
2nd CPU is needed
With this card, 3x PCIe slots (LP/ x16) change to 1x PCIe slots (LP/ x16) + 4x PCIe slots (FH/ x8).
Please refer to ‘Chapter 5 – Graphics cards’ for more details about the supported GPGPUs’.
cnfgTX2550M7-20231117_I_riser_cardPage 33 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
Option d) Full height 2slot PCIe riser card (x16 Gen5) with PCIe support bracket with Retimer
If the below 2 options are selected, 6x PCIe slots (LP/ x16) change to 2x PCIe slots (LP/ x16) + 4x PCIe slots (FH/ x16).
PCIe cards and double width GPGPUs can be supported on 4x PCIe slots (FH/ x16).
One full height GPGPU can be installed on 1x PCIe slot (FH/ x16).
Support brackets are required for the cooling of passively cooled FH GPUs.“
A100, A30, A16, L40, H100 and / or FH PCIe card is selected
Full height 2slot PCIe riser card right (CPU 1) with PCIe support bracket with Retimer
PYBPRE643 / PY-PRE643
x16 Gen5 PCI riser card
Note:
With this card, 3x PCIe slots (LP/ x16) change to 1x PCIe slots (LP/ x16) + 2x PCIe slots (FH/ x16).
Please refer to ‘Chapter 5 – Graphics cards’ for more details about the supported GPGPUs’.
Please refer to chapter ‘Thermal’ for more details about limitations’.
Full height 2slot PCIe riser card left (CPU 2) with PCIe support bracket with Retimer
PYBPRE644 / PY-PRE644
x16 Gen5 PCI riser card
Note:
2nd CPU is needed.
With this card, 3x PCIe slots (LP/ x16) change to 1x PCIe slots (LP/ x16) + 2x PCIe slots (FH/ x16).
Please refer to ‘Chapter 5 – Graphics cards’ for more details about the supported GPGPUs'.
Option e) Full height 2slot PCIe riser card (x16 Gen5) without PCIe support bracket with Retimer
If the below 2 options are selected, 6x PCIe slots (LP/ x16) change to 2x PCIe slots (LP/ x16) + 4x PCIe slots (FH/ x16).
PCIe cards and double width GPGPUs can be supported on 4x PCIe slots (FH/ x16).
One full height GPGPU can be installed on 1x PCIe slot (FH/ x16).
T400 4GB, A2, L4, RTX A6000, RTX A4500, RTX 6000 and / or FH PCIe card is selected
Full height 2slot PCIe riser card right (CPU 1) without PCIe support bracket with Retimer
PYBPRE645 / PY-PRE645
x16 Gen5 PCI riser card
Note:
With this card, 3x PCIe slots (LP/ x16) change to 1x PCIe slots (LP/ x16) + 2x PCIe slots (FH/ x16).
Please refer to ‘Chapter 5 – Graphics cards’ for more details about the supported GPGPUs’.
Please refer to chapter ‘Thermal’ for more details about limitations’.
Full height 2slot PCIe riser card left (CPU 2) without PCIe support bracket with Retimer
PYBPRE646 / PY-PRE646
x16 Gen5 PCI riser card
Note:
2nd CPU is needed.
With this card, 3x PCIe slots (LP/ x16) change to 1x PCIe slots (LP/ x16) + 2x PCIe slots (FH/ x16).
Please refer to ‘Chapter 5 – Graphics cards’ for more details about the supported GPGPUs'.
Option f) Full height 4slot PCIe riser card (x8 Gen5) with Retimer
If the below 2 options are selected, 6x PCIe slots (LP/ x16) change to 2x PCIe slots (LP/ x16) + 8x PCIe slots (FH/ x8).
GPGPU(Double height) cannot be supported.
T400 4GB and / or FH PCIe card is selected
Full height 4slot PCIe riser card right (CPU1) with Retimer
PYBPRE851 / PY-PRE851
x8 Gen5 PCI riser card
Note:
With this card, 3x PCIe slots (LP/ x16) change to 1x PCIe slots (LP/ x16) + 4x PCIe slots (FH/ x8).
Please refer to ‘Chapter 5 – Graphics cards’ for more details about the supported GPGPUs’.
Please refer to chapter ‘Thermal’ for more details about limitations’.
Full height 4slot PCIe riser card left (CPU2) with Retimer
PYBPRE852 / PY-PRE852
x8 Gen5 PCI riser card
Note:
2nd CPU is needed
With this card, 3x PCIe slots (LP/ x16) change to 1x PCIe slots (LP/ x16) + 4x PCIe slots (FH/ x8).
Please refer to ‘Chapter 5 – Graphics cards’ for more details about the supported GPGPUs’.
cnfgTX2550M7-20231117_I_riser_cardPage 34 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
Chapter 15 - Power supply unit, power cable, certifications, region kits
R
Power supply unit
modular redundant Power Supply
2nd PSU for redundancy basically.
occupies hot plug PSU slot, min. 1 / max. 2x per system. The different PSU mixed configuration does NOT support.
input nominal voltage (AC): 100V-240V, max: 90V-264V; input dropout 10ms/100% load, 47Hz-63Hz
500W platinum PSU
94% eff. Connector type: C13, APAC/JAPAN region only
PYBPU501PY-PU501
500W titanium PSU
96% eff. Connector type: C13, nom. 220-240V, max. 180-264V
PYBPU503PY-PU503
900W platinum PSU
94% eff. Connector type: C13, APAC/JAPAN region only
PYBPU902PY-PU902
900W titanium PSU
96% eff. nom. 220-240V, max. 180-264V
PYBPU901PY-PU901
1600W platinum PSU
94% eff. Connector type: C13, APAC/JAPAN region only
PYBPU163PY-PU163
1600W titanium PSU
96% eff. Connector type: C13, nom. 220-240V, max. 180-264V
PYBPU165PY-PU165
2200W platinum PSU
94% eff. Connector type: C19 200~240V only, APAC/JAPAN region only
PYBPU221PY-PU221
2400W Titanium PSU
96% eff. Connector type: C19, nom. 220-240V, max. 180-264V
PYBPU243PY-PU243
Dummy module instead PSU
Dummy module for closing the 2nd PSU hole, in case only 1 PSU is equipped, max. 1x per systemPYBDMP06-
If Power consumption error occureson 2400W PSU, 'No Redundant' can be selected
PYBVS002
No Power redundant option
If this option is selected, the system may shutdown at the worst case
Note: 2x 1600W or 2x 2200W or 2x 2400W are mandatory.
in one PSU failure. Not allow activity exchange for PSU even if
If Power budget isn't enough even if 2400W PSU is used, it can be used.
two PSU are selected.
max. 1x per system
Power cord option for Tower Server, 1x per PSU
Cable powercord (USA) 15A, 1.8m, black, NEMA 5-15 connector 498G -> C13 (plug), 15A, , rack or wall
T26139-Y1741-E90T26139-Y1741-L90
Cable powercord (Taiwan), 1.8m, rack or wall
T26139-Y1757-E10T26139-Y1757-L10
Cable powercord (D, A, B, F, NL, FIN, N, S, E, P, RUS, TR), 1.8m, grey
T26139-Y1740-E10T26139-Y1740-L10
Cable powercord (China), 1.8m, grey
T26139-Y1743-E10-
Cable powercord (China), 1.8m, black
-T26139-Y1751-L10
Cable powercord (UK, IR), 1.8m, grey
T26139-Y1744-E10T26139-Y1744-L10
Cable powercord (I), 1.8m, grey
T26139-Y1745-E10T26139-Y1745-L10
Cable powercord (DK), 1.8m, grey
T26139-Y1746-E10T26139-Y1746-L10
Cable powercord (ISR), 2.5m, black
T26139-Y1747-E18T26139-Y1747-L18
2200w or more
Power cord 16A IEC320 C19->CEE 7/7, 2.5m for 2200W/2400W PSU
S26361-F3151-L100
Power cord 16A IEC320 C19->C20, 3.5m for 2200W/2400W PSU
S26361-F3151-E300S26361-F3151-L300
Power cord IEC320 C19 -> US NEMA L6-20p, 4m for 2200W/2400W PSU
S26361-F3151-E500S26361-F3151-L500
common
no power cord
T26139-Y3850-E10
Power cord option for Rack Server, 1x per PSU
Cable powercord rack, 1.8m, black, IEC 320 C14 -> C13 (10A plug)
T26139-Y1968-E180T26139-Y1968-L180
Cable powercord rack, 2.5m, black, IEC 320 C14 -> C13 (10A plug)
T26139-Y1968-E250T26139-Y1968-L250
Cable powercord rack, 4m, black, IEC 320 C14 -> C13 (10A plug)
T26139-Y1968-E100T26139-Y1968-L10
Cable powercord (USA) 15A, 1.8m, black, NEMA 5-15 connector 498G -> C13 (plug), 15A, , rack or wall
T26139-Y1741-E90T26139-Y1741-L90
Cable powercord (Taiwan), 1.8m, rack or wall
T26139-Y1757-E10T26139-Y1757-L10
Cable powercord (D, A, B, F, NL, FIN, N, S, E, P, RUS, TR), 1.8m, grey
T26139-Y1740-E10T26139-Y1740-L10
Cable powercord (China), 1.8m, grey
T26139-Y1743-E10-
Cable powercord (China), 1.8m, black
-T26139-Y1751-L10
Cable powercord (UK, IR), 1.8m, grey
T26139-Y1744-E10T26139-Y1744-L10
Cable powercord (I), 1.8m, grey
T26139-Y1745-E10T26139-Y1745-L10
Cable powercord (DK), 1.8m, grey
T26139-Y1746-E10T26139-Y1746-L10
Cable powercord (ISR), 2.5m, black
T26139-Y1747-E18T26139-Y1747-L18
2200w or more
Power cord 16A IEC320 C19->CEE 7/7, 2.5m for 2200W/2400W PSU
S26361-F3151-L100
Power cord 16A IEC320 C19->C20, 3.5m for 2200W/2400W PSU
S26361-F3151-E300S26361-F3151-L300
Power cord IEC320 C19 -> US NEMA L6-20p, 4m for 2200W/2400W PSU
S26361-F3151-E500S26361-F3151-L500
common
no power cord
T26139-Y3850-E10
One region kit mandatory
S26361-F1452-E100S26361-F1452-E101S26361-F1452-E130S26361-F1452-E140
REGION KIT APAC/EMEARegion Kit China for CCCREGION KIT AmericaREGION KIT Europe
For Shipments to Asia pacific, Contains warranty sheet and For Shipments to America
America, EMEA regionssafety instructions for China, regions
need to be included always into
the order from China country
1x per system1x per system1x per system1x per system
S26361-F3301-E120
Certification for China, (CCC)
Certification for China, (CCC), Reduced component
selection possible, only with no power cord option
1x per system
S
cnfgTX2550M7-20231117_UPage 35 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
Chapter 16 - Accessories
S
USB Mouse:
Mouse M520 Black
n/aS26381-K467-L100
Mouse M520 Greyn/a
S26381-K467-L101
Mouse M530 Blackn/aS26381-K468-L100
Mouse M530 Greyn/aS26381-K468-L101
USB Keyboards for Tower Servers for following countries:
Country versionFUJITSU Keyboard KB521 USB (grey)
US/ int 105 keys (UK keyboard + US int. Layout)S26381-K521-L102
Czech/SlovakS26381-K521-L104
US 104 keys (US keyboard + US layout)S26381-K521-L110
GermanyS26381-K521-L120
Germany / IntS26381-K521-L122
FranceS26381-K521-L140
Sweden / FinlandS26381-K521-L154
United KingdomS26381-K521-L165
SwitzerlandS26381-K521-L170
SpainS26381-K521-L180
ItalyS26381-K521-L185
USB Optical Disc Drive
External Ultra Slim Portable DVD Writer (Hitachi-LG)
S26341-F103-L142
T
cnfgTX2550M7-20231117_B devicesPage 36 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
Chapter 17 - Energy Star
T
will be expired after 2024-1-11will be expired after 2024-1-11will be effective after 2024-1-12will be effective after 2024-1-12
S26361-F3301-E551S26361-F3301-E552PYBES26PYBES27
TX2550 Mx E-Star Fam1TX2550 Mx E-Star Fam2TX2550 Mx E-Star Fam1TX2550 Mx E-Star Fam2
Limits configuration in accordance Limits configuration in accordance Limits configuration in accordance Limits configuration in accordance
with Energy Star requirements for systems with 1 CPUwith Energy Star requirements for systems with 2 CPUwith Energy Star requirements for systems with 1 CPUwith Energy Star requirements for systems with 2 CPU
max. 1x per systemmax. 1x per systemmax. 1x per systemmax. 1x per system
1 CPU Variant1 CPU Variant
notallowed are:
limitations for E-Star Fam1certification
2 CPU Variant
notallowed are:
limitations for E-Star Fam2certification
notallowed are:
limitations for E-Star Fam1certification
2 CPU Variant
notallowed are:
limitations for E-Star Fam2certification
-2 CPU configuration
-1 CPU configuration
-2 CPU configuration
-1 CPU configuration
-CPU Xeon Bronze 3408U
-CPU Xeon Bronze 3408U
-CPU Xeon Bronze 3408
-CPU Xeon Silver 4410Y
-CPU Xeon Silver 4410Y
-CPU Xeon Silver 4416+
-CPU Xeon Silver 4416+
-CPU Xeon Gold 5415+
-CPU Xeon Gold 5415+
-CPU Xeon Gold 6426Y
-CPU Xeon Gold 6426Y
-CPU Xeon Gold 6434
-CPU Xeon Gold 6434
-CPU Xeon platinum 8444H
-CPU Xeon platinum 8444H
-CPU Xeon Gold 5416S
-CPU Xeon Gold 5416S
-CPU Xeon Silver 4410T
-CPU Xeon Silver 4410T
-900W platinum PSU
-900W platinum PSU
-1600W platinum PSU
-1600W platinum PSU
-2200W platinum PSU
-2200W platinum PSU
ENERGY STAR-configurations with one CPU will be labeled:
PRIMERGY TX2550 M7 E-Star Fam1
ENERGY STAR-configurations with two CPU will be labeled:
PRIMERGY TX2550 M7 E-Star Fam2
non ENERGY STAR-configurationen will be labeled:
PRIMERGY TX2550 M7
U
cnfgTX2550M7-20231117_ergy StarPage 37 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
Chapter 18 - others (ErP Lot 9 restriction)
U
*Region kit Europe must be orderd for
shipment toship in EU and EFTA
Region Kits, 1x per System
Region Kit APAC/EMEA/India,
Contains warranty sheet and safety instructions
for APAC, EMEA and India
Region Kit America,
Contains warranty sheet, registration hints and
safety instructions for America
S26361-F1452-E100
Region Kits, 1x per System
Region Kit Europe*,
Contains warranty sheet and safety instructions
in German, English, French, Spanish, Italian,
Polish, Russian and Welsh language
S26361-F1452-E140
S26361-F1452-E130
Restriction for ErP Lot 9 directive,
Not allowed: (For all base unit)
- 500W platinum PSU
- 900W platinum PSU
- 1600W platinum PSU
- 2200W platinum PSU
need to select one of PYBETL17 or PYBETL18
ErP Lot9 Restriction for 16GB DIMM, 1x per System
For 2.5" base unit only
2.5" base unit: PYT2557T2N, PYT2557TBN, PYT2557TCN, PYT2557R2N,
PYT2557RAN
Erp Lot9 configuration 1
PYBETL17
ErP Lot9 Restriction for >=32GB DIMM, 1x per System
For all 3.5", 2.5" base unit
3.5" base unti: PYT2557T3N, PYT2557TAN, PYT2557R3N
2.5" base unit: PYT2557T2N, PYT2557TBN, PYT2557TCN, PYT2557R2N,
PYT2557RAN
ErP Lot 9 configuration 2
PYBETL18
Restriction for ErP Lot9 directive,
* this option is NOT avaialble for 3.5" base unit.
(For PYT2557T2N, PYT2557TBN, PYT2557TCN, PYT2557R2N,
PYT2557RAN)
Not allowed:
-CPU: Bronze 3408U (PYBCP65XR)
-NVIDIAT400 (PYBVG4T2L)
-NVMe SSD (PYBBA24PJ, PYBBA24PK, PYBCBE024,
PYBCBE025)
Max qty of 1G LAN card restricted to max. 2
1G LAN: S26361-F4610-E204, PYBLA284L, PYBLA284
Restriction for ErP Lot9 directive,
(For PYT2557T3N, PYT2557TAN, PYT2557R3N,
PYT2557T2N, PYT2557TBN, PYT2557TCN, PYT2557R2N,
PYT2557RAN)
Not allowed:
-CPU: Bronze 3408U (PYBCP65XR)
-DIMM: 16GB DIMM (PYBME16SL)
V
cnfgTX2550M7-20231117_P Lot9Page 38 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
Chapter 19 - others
V
PYBRMC44
PY-RMC44
iRMC advanced pack
integrated remote Management controller activation key for graphical
console redirection and remote media redirection
max. 1x per system
PYBLCM14
embedded Lifecycle Management (eLCM)Loose delivery
Server Online UpdateeLCM Activation Pack
OS driver Update(Node Locked License)
Hardware firmware updatePY-LCM14
Server Offline Updateoptions contains:
Hardware update via Update Manager Express- Paper with TAN for Licensekey
PrimeCollect
Autonomous creation of Primecollect archives
Custom Image (Jukebox function)
Automatic and manual download of CD and DVD Images
Automatic and manual start of CD and DVD Images
max. 1x per system
PYBSSS3
iRMC standard/legacy Option
When this product is orderd, following iRMC default setting is changed.
Unique default password: No. The fixed password is printed on ID tag.
SSH: Enabled
USB Host LAN : Enabled
Force to change default pwd to use Redfish/RESTful/other interfaces: No
max. 1x per system
PY TX2550 M7 Tower 4x3.5' basic and PY
Advanced Thermal Designis not available with LTO drives.
TX2550 M7 Tower 8x2.5' basic do not support
ATD options! For the detail, refer to the 'Therma
chapter'.
S26361-F3776-E440S26361-F3776-E445
Cool-safe ® Advanced Thermal design 40°CCool-safe ® Advanced Thermal design 45°C
enables the PRIMERGY Server to cope with enables the PRIMERGY Server to cope with temperatures from
temperatures from 5-40° in operating mode due to 5-45° in operating mode due to extended Fan settings
extended Fan settings
this setting can be activated ex factory onlythis setting can be activated ex factory only
max. 1x per systemmax. 1x per system
PYBETA1
Configuration Thermal Design 30°C(CTD30)
Sets the PRIMERGY server to support temperatures of up to
30 ° C in operating mode for the configuration with thermal
restriction.
Refer to Chapter15-Thermal Rule
this setting can be activated ex factory only
max. 1x per system
cnfgTX2550M7-20231117_hersPage 39 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
PYBCOM08
PY-COM08
Serial Port Option
RS-232-C for a RS-232-C Serial Port Interface
does NOT occupy PCI slot
max. 1x per system
PYBVAP08
PY-VAP08
Front VGA Option
VGA Interface
does NOT occupy PCI slot
max. 1x per system
will be EOL in CQ2'24
PYBTPM14
PY-TPM14
TPM 2.0 Module SPI
required for Microsoft Windows Server 2022 (host OS)
max. 1x per system
will be available in CQ1'24
PYBTPM20
PY-TPM20
TPM 2.0 Module V2
required for Microsoft Windows Server 2022 (host OS)
max. 1x per system
PYBNTPM
No TPM for WINSVR
Either PYBTPM14 or PYBNTPM is required
in ordering Windows Server 2022 OEM
max. 1x per system
When Windows Server 2022 is used as a host OS, PYBTPM14, PY-TPM14, PYBTPM20 or PY-TPM20 is
required. This requirement, however, can be waived if the end customer expresses their desire to
configure the server system without a TPM. In that case, No TPM for WINSVR can be selected.
When Windows Server 2022 is used as a guest OS, TPMs are not necessary.
OS support matrix:
PYBTPM14PYBTPM20
Operating system for host OSPY-TPM14PY-TPM20
Windows Server 2022requiredrequired
Windows Server 2019supportedsupported
Windows Server 2016supported-
Red Hat Enterprise Linux 8supportedsupported
Red Hat Enterprise Linux 7supportedsupported
SUSE Linux Enterprise Server 15--
VMware ESXi 7.0supportedsupported
VMware ESXi 6.7supported-
PYBTPM14/PY-TPM14 are currently available when will be EOL in CQ2'24
PYBTPM20/PY-TPM20 will be an alternative in CQ1'24
because new TPM supports mandatory to fit to new Windows requirement
New TPM are backward compatible with former TPMs.
PY-FOP17
4U Rack Front Bezel
Front Bezel on front Base
max. 1x per system
Your server is ready
cnfgTX2550M7-20231117_hersPage 40 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
Chapter 20 - Thermal Rule
Basic Model(PYT2557T3N / PYT2557T2N) ATD40 and ATD45 can't be supported.
Basic model
CPUMemoryDrive bayOption cardAmbient
4x3.5"8x3.5"8x2.5"LP PCIe / Nvidia T400FH PCIe / GPGPU on PCI RiserTemp.
No limitation
No limitationNo limitationLevel1-6 / Nvidia T400Not support
35C
Basic model for PCIe Level7
CPUMemoryDrive bayOption cardAmbient
4x3.5"8x3.5"8x2.5"LP PCIe / Nvidia T400FH PCIe / GPGPU on PCI RiserTemp.
CPU A
16GB - 64GB DDR5
on board SATA or RAID
CPU B
controller on slot1.
Level1-7 / Nvidia T400Not support
30C
CPU C
CPU D
Not supportNot support
* Need to select Configuration Thermal Design 30℃(PYBETA1)
Standard Model(PYT2557TAN/PYT2557TBN/PYT2557TCN/PYT2557R3N/PYT2557R2N/PYT2557RAN)
Standard model for ATD45
CPUMemoryDrive bayOption cardAmbient
LP PCIe / Nvidia T400FH PCIe / GPGPU on PCI RiserTemp.
No limitation
No limitationNo limitationLevel1-4 / Nvidia T400Not support
45C
* SSD support only. HDD can't be supported. LTO can't be supported.
Standard model for ATD40
CPUMemoryDrive bayOption cardAmbient
LP PCIe / Nvidia T400FH PCIe / GPGPU on PCI RiserTemp.
No limitation
No limitationNo limitationLevel1-5 / Nvidia T400Not support
40C
* SSD support only. HDD can't be supported. LTO can't be supported.
Standard model
CPUMemoryDrive bayOption cardAmbient
LP PCIe / Nvidia T400GPGPU on PCI Riser / FH PCIeTemp.
No limitation
No limitationNo limitationLevel1-6 / Nvidia T400Not support
35C
Standard model for FH PCIe/GPGPU on PCI Riser
CPUMemoryDrive bayOption cardAmbient
LP PCIe / Nvidia T400GPGPU on PCI Riser / FH PCIeTemp.
No limitation No limitation
No limitation
Level1-6 / Nvidia T400
GPGPU Group A / Level1-6
SSD only
GPGPU Group B / Level1-6
30C
* Need to select Configuration Thermal Design 30℃(PYBETA1)
Standard model for PCIe Level7
CPUMemoryDrive bayOption cardAmbient
8x3.5"12x3.5"8x2.5"LP PCIe / Nvidia T400FH PCIe / GPGPU on PCI RiserTemp.
CPU A
16GB - 64GB DDR5
on board SATA or RAID
CPU B
controller on slot1.
Level1-7 / Nvidia T400Not support
30C
CPU C
CPU D
Not supportNot support
* Need to select Configuration Thermal Design 30℃(PYBETA1)
cnfgTX2550M7-20231117_ermalPage 41 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
Option card: PCIe Level for Thermal condition
Card
RAID/SASPDUAL CP100
PDUAL CP300
PSAS CP600e FH / LP
PSAS CP600i LP
PSAS CP600i LP for LTO
PRAID CP600i LP
PRAID EP640i LP
PRAID EP680i LP / NVMe FH / LP
PRAID EP680e RAID Contr. FH/LP
PSAS CP2100-8i LP
PSAS CP2200-16i LP / NVMe FH / LP
PSAS CP 2200-16i LP for LTO
PRAID EP3252-8i LP
PRAID EP3254-8i LP
PRAID EP3258-16i LP / NVMe FH / LP
PRAID EP740i LP / NVMe FH / LP
PFC EP LPe31000 1x 16Gb FH / LP
PFC EP LPe31002 2x 16Gb FH / LP
PFC EP LPe35000 1X 32GFC PCIe v4 / LP
PFC EP LPe35002 2X 32GFC PCIe v4 / LP
PFC EP LPe36000 1X 32GFC PCIe v4 / LP
PFC EP LPe36002 2X 32GFC PCIe v4 / LP
PFC EP QLE2690 1x 16Gb FH / LP
PFC EP QLE2692 2x 16Gb FH / LP
PFC EP QLE2770 1X 32GFC PCIe v4 / LP
PFC EP QLE2772 2X 32GFC PCIe v4 / LP
PFC EP QLE2870 1X 32GFC PCIe v4 / LP
PFC EP QLE2872 2X 32GFC PCIe v4 / LP
PLAN CP 4x1Gbit Cu Intel I350-T4 LP
PLAN EP E810-CQDA2 2X 100G QSFP28 LP
PLAN EP E810-XXVDA2 2X 25G SFP28 FH / LP
PLAN EP E810-XXVDA4 4X 25G SFP28 LP
PLAN EP MCX6-DX 100Gb 2p QSFP28 LP
PLAN EP X710-DA2 2x10Gb SFP+ FH / LP
PLAN EP X710-DA4 4x10Gb SFP+ FH / LP
PLAN EP X710-T2L 2X 10GBASE-T FH / LP
PLAN EP X710-T4L 4X 10GBASE-T FH / LP
PLAN CP BCM5719-4P 4X 1000BASE-T PCIe FH / LP
PLAN EP P210P 2x10Gb SFP FH / LP
PLAN EP P210TP 2X 10GBASE-T PCIe FH / LP
PLAN EP MCX6-LX 25Gb 2p SFP28 PCIe FH / LP
PLAN EP P225P 25Gb 2p SFP28 PCIe FH / LP
PLAN EP P2100G 100Gb 2p QSFP56 PCIe LP
Product Number
PYBVG4A8
PYBVG4L1
PYBVG4A4
PYBVG4A5
PYBVG4A1
PYBVG4L2
PYBGP4A10
PYBVG4A7
PYBGP4H11
PYBVG4A2
PYBVG4L3
Product Number
FH
PYBDMCP24
PYBDMCP35
PYBSC4FAE
- / PYBSR4C62
PYBSR4C6E
- / PYBSC4MA2
FC
LAN
- / PYBSR4MA4
(TBD)
S26361-F5596-E1
S26361-F5596-E2
PYBFC421
PYBFC422
PYBFC441
PYBFC442
S26361-F5580-E1
S26361-F5580-E2
PYBFC411
PYBFC412
PYBFC431
PYBFC432
-
PYBLA432
PYBLA402
PYBLA404
PYBLA412
S26361-F3640-E2
S26361-F3640-E4
PYBLA342
PYBLA344
PYBLA284
PYBLA3J2
PYBLA3K2
PYBLA4024
PYBLA3H2
PYBLA442
LP
PYBDMCP24L
PYBDMCP35L
PYBSC4FAEL
PYBSC4FAL
PYBSC4FA2L
PYBSR4FAL
PYBSR4C63L
PYBSR4C6L / PYBSR4C62L
PYBSR4C6EL
PYBSC3MA2L
PYBSC4MA1L / PYBSC4MA2L
PYBSC4MA3L
PYBSR4MA1L
PYBSR4MA2L
PYBSR4MA3L / PYBSR4MA4L
(TBD)
S26361-F5596-E201
S26361-F5596-E202
PYBFC421L
PYBFC422L
PYBFC441L
PYBFC442L
S26361-F5580-E201
S26361-F5580-E202
PYBFC411L
PYBFC412L
PYBFC431L
PYBFC432L
S26361-F4610-E204
PYBLA432L
PYBLA402L
PYBLA404L
PYBLA412L
S26361-F3640-E202
S26361-F3640-E204
PYBLA342L
PYBLA344L
PYBLA284L
PYBLA3J2L
PYBLA3K2L
PYBLA402L4
PYBLA3H2L
PYBLA442L
PCIe Level
Level4
Level5
Level3
Level3
Level3
Level3
Level3
Level3
Level3
Level3
Level4
Level4
Level4
Level4
Level4
Level4
Level3
Level3
Level4
Level4
Level4
Level4
Level3
Level3
Level4
Level4
Level4
Level4
Level1
Level7
Level5
Level7
Level7
Level1
Level3
Level2
Level3
Level1
Level3
Level5
Level5
Level3
Level5
Option card: GPGPU Group
GroupCard
NVIDIA A2
NVIDIA L4
NVIDIA A16
NVIDIA A30
Group A
NVIDIA A40
NVIDIA L40
NVIDIA A100 80GB
NVIDIA RTX A4500
NVIDIA H100
Group B
NVIDIA RTX A6000
NVIDIA RTX 6000
S
cnfgTX2550M7-20231117_ermalPage 42 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
Date of changeConfigurator revisionFolder / order code / descriptionWhat has been changed / commentName
17.11.2023
13.11.2023
26.10.2023
25.10.2023
24.10.2023
19.10.2023
18.10.2023
16.10.2023
13.10.2023
13.10.2023
13.10.2023
04.10.2023
03.10.2023
03.10.2023
22.09.2023
20.09.2023
1.51
1.50
1.49
1.48
1.47
1.46
1.45
1.44
1.43
1.43
1,42
1.41
1.40
1.39
1,38
1,37
LAN, FC_IB
19.09.2023
14.09.2023
12.09.2023
08.09.2023
04.09.2023
30.08.2023
28.08.2023
28.08.2023
31.07.2023
31.07.2023
28.07.2023
20.07.2023
1.36
1.35
1.34
1,33
1,32
1.31
1.30
1.29
1.28
1.27
1.26
1.25
19.07.2023
14.07.2023
12.07.2023
11.07.2023
04.07.2023
04.07.2023
30.06.2023
29.06.2023
22.06.2023
15.06.2023
13.06.2023
07.06.2023
1.24
1.23
1.22
1.21
1.20
1.19
1.18
1.17
1.16
1.15
1.14
1.13
06.06.2023
05.06.2023
02.06.2023
02.06.2023
02.06.2023
02.06.2023
31.05.2023
30.05.2023
23.05.2023
22.05.2023
16.05.2023
15.05.2023
26.04.2023
1.12
1.11
1.10
1.09
1.08
1.07
1.06
1.05
1.04
1.03
1.02
1.01
1.0
QLE287x released.
Change schedule info of MCX6-LX and Broadcom 25/100G cards
Other (iRMC)Add "iRMC standard/legacy Option" PYBSSS3 in others sheet.
RAMRmoved DDR5 5600 memory
HDD_SSDupdated the description about max qty for M.2 SATA/PCIe drives.
RAMAdded DDR5 Registered DIMM 5600MHz
HDD_SSDreleased SED HDD/SSD
RAIDupdated Note for Intel VROC (SATA RAID)
GFX_FPGAAdd L40S/RTX 4000
HDD_SSDupdated availability schedule
RAIDreleased Intel VROC (VMD NVMe RAID)
HDD_SSDupdated the EOL informaiton for PCIe-SSD
LANAdd I350-T2 PCIe
ODD, othersAdd new order code for half height ODDs, and current order code will be EOL
Add new TPM
RAIDreleased Intel VROC (SATA RAID)
HDD_SSDadded the limitation about VROC for PCIe-SSD
HDD_SSD, HDD_SSD (short depth)updated availability schedule
added the following drives as new products
-Samsung PM1653 as SSD SAS 2.5"
-Samsung PM897a/PM893a as SSD SATA 2.5"/3.5"
Energy Staradded E-Star Fam1/Fam2 Certification for ENERGY STAR V4.0
RAID, backupupdated availability schedule
ThermalModified thermal rule for FH PCIe/GPGPU on PCI Riser for clear information
added the EOL status for HDD SAS 15K and HDD 2.5" BC-SATA/SAS
HDD_SSD
updated availability schedules for SSD SAS "PM7"
HDD_SSD
HD_SSD, Thermaladded PDUAL CP300
PYBDMCP35, PYBDMCP35L, PY-DMCP35
PCI_riser_cardchanged chapter name to ’PCI_riser_card’ and updated description
ThermalAdding MCX6-LX 25G and P(N)225P, P(N)2100G info to Thermal sheet
HD_SSDrevised the order codes for Kioxia CM7 15.36TB
HD_SSDadded the PCIe-SSD "kioxia CM7 series"
base, PCI_RiserSeparating PCI_Riser section to Chapter 14 from Chapter 1 - base unit
LANAdding Broadcom 25G/100G cards.
Adding NVIDIA 25G cards.
Deleting E810-CQDA2 and MCX6-DX 100G FH cards because thermal level is 7
and cannot be used it as FH.
GFX_FPGADelete A30X/A100X.
FC_IBDelete the restriction of QLE277x because System T50 includes these cards and
no issues.
ThermalRevice the limitation for RTX A6000
RAIDupdated availability schedule
GFX_FPGAAdded the RTX 6000
ThermalAdded the limitation for RTX A6000
othersNo TPM for WINSVR added
ThermalModified for clear information
BaseRemoved '1x USB 3.1 Gen1(type A)' from Interfaces internal
HD_cageRemoved availability schedule for PYBBA28ST
GFX_FPGAL4/L40
updated availability schedule
RAIDadded Intel VROC (SATA RAID)
added Intel VROC Upgrade Key
PYBRLVR02, PY-RLVR02
updated availability schedule
GFX_FPGAUpdated NVLink and L4 and L40, H100.
HD_cageRemoved 'except for PCIeSSDs'
HD_SSDupdated availability schedule
ThermalAdded H100 limitation.
LANChange max number of Broadcom 10G LAN P210P, P210TP LP cards from 6 to
4.
This is due to SA:233766419. Slot#3 and slot#10 cannot be used.
HD_cageRemove the limitation for the number of disks from
PYBBA24PJ/PYBBA24PK/PYBCBE024/PYBCBE025
HD_cageAdded PY-BA34SA/PY-BA34SB/PY-BA28SQ/PY-BA28SR/PY-BA28SS/PY-
BA28ST/PY-BA24PJ/PY-BA24PK/PY-CBE024/PY-CBE025
HD_cageRemove the limitation for the number of disks from PYBBA28SS
updated availability schedule for PYBBA28ST
ThermalRevice the detail
HD_SSDremoved the BC-SATA 20TB due to release cancel
HD_SSDchanged the max qty from "2" to "1" for M.2 SSD due to not support of VROC
RAID, backupupdated availability schedule
1st release
F. Kanega
H. Ogino
H. Konno
Y. Sugiyama
T. Sudou
a
T. Sudou
T. Sudou
Y. Sugiyama
F. Kanega
H. Konno
T. Sudou
Y. Sugiyama
Y. Sugiyama
T. Sudou
Y. Sugiyama
Y. Sugiyama
T. Sudou
F. Kanega
Y. Sugiyama
Y. Sugiyama
F. Kanega
S. Fujita
T. Sudou
a
S. Fujita
K. Nishihara
S. Fujita
S. Fujita
T. Sudou
a
T. Sudou
M. Takaoka/T. Sasaki
S. Fujita
T. Sudou
S. Fujita
F. Kanega
S. Fujita
S. Fujita
S. Fujita
S. Fujita
Y. Sugiyama
Y. Sugiyama
T. Sudou
S. Fujita
cnfgTX2550M7-20231117_ange_historyPage 43 of 43
2024年9月26日发(作者:梁丘芸芸)
PRIMERGY TX2550 M7
Tower or 4U Rack server
ChapterFolder
Cover
Description
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Base
CPU
RAM
GFX
HD_cage
RAID
ODD
Backup
HD_SSD
LAN
FC_IB
PCI_riser_card
PSU
USB_devices
Energy Star
ErP Lot9
others
Thermal
Content
List of content, Instructions for usage of this configurator,
abbreviations
System Description for easier understanding
Describes base units of TX2550 M7
Describes rack mount kits and services
Order codes, information Xeon processors
DDR5 System memory (RAM) and memory modes
Graphics-, Grid-cards, GPU and Xeon Co processors
HDD cage kits
SAS / RAID Controller and components
Optical disk drives (DVD, DVD-rw, Blu ray)
LTO drives & RDX drive
Storage drives - PCIe SSD - SAS/SATA SSD & HDD
LAN Components
Fibre Channel Controller
Infiniband Controller
PCI Riser
Power supply units, power cables, country specifics
Keyboards, Mice, USB devices
Energy Star limitation
Erp Lot9 limitation
System Management, ATD, RS232 port, TPM module
Thermal Rule
Instructions
This document contains basic product and configuration information that supports you in more complicated configurations.
In any case we recommend to use the WebArchitect to make sure, that you configure a valid system.
This System configurator is divided into several chapters. They are identical to the current price list and WebArchitect.
Please follow this document step by step from the top to the bottom
Chapter xx - description of chapter
Text fields with grey color offer extra information for related topics (e.g prerequesites, technical back
ground, configuration rules, limitations, …
S26361-F4610-E2
S26361-F4610-L3
PLAN 2x1Gb Ethern. Controller
i350-T2 chip (based on Intel Powerville) offers
2x1Gb RJ45 connectors
PCIe Gen2 x4 full height card
max. 6x per system
<-- order code E-part (bold) --
<-- order code L-part (bold)
<-- "name" of this part
<--description of this part, in same cases as well description of content
<--requires a free PCIe slot --> means total amount of PCIe slots reduced
<--indicates how often this part can be configured in the related Server
New order code
PYBVAP05
PY-VAP05
Front VGA connector (15-pin)
Front VGA connector (15-pin) including cable
and front connector
Not for 12x3.5", 24x2.5", 64xEDSFF base unit.
max. 1x per system
<-- "PYB" order code (bold) for BTO(Built to Order) part
<-- "PY-" order code (bold) for Loose delivery part
<-- "name" of this part
<--description of this part, in same cases as well description of content
<-- Limitation for this part
<--indicates how many this part can be configured in the related Server
For further information see:
Link to datasheet:
/dmsp/Publications/public/
/products/standard_servers/
(internet)
/com/order-supply/configurators/primergy_config/Pages/
(extranet)
Fujitsu is providing the content of this document with very high accuracy. In case you identify a mistake, we would kindly encourage you to inform us.
We kindly ask for understanding, that errors still may occur and that Fujitsu may change this document without notice
Abbreviations
SAS
SATA
HDD
SSD
SFF
LFF
CPU
RAID
Spaces
vSAN
storage tiering
hot data
cold data
ODD
OS
E-Part
L-Part
Drives, RAID
Drives, RAID
Drives
Drives
Drives
Drives
Processor
Drives, RAID
OS
OS
RAID
Drives
Drives
Drives
operating system
"Einbau-Part"
"Lose Lieferung-Part"
Serial attached SCSI Device (HDD, SSD, LTO drives); SAS2.0 = 6GBit/s; SAS3.0 = 12GBit/s
Serial ATA (HDD, SSD) current SATA speed = 6GBit/s
Hard disk drive (Non volatile storage device), 2.5" (SFF) or 3.5" (LFF)
Solid state disk (Non volatile storage device), 2.5" (SFF)
small form factor (=2.5")
large form factor (=3.5")
central processing unit ("processor")
RAID 0 = max speed, RAID 1 = mirroring, RAID 5 = 1 out of x drives is spare
Microsoft spaces, optimized in Win2012 R2 offers software RAID and storage tiering
offers optimized storage allocation (fast area for "hot data"; slower area for "cold data")
Data which are currently being processed
Data which are currently not processed (only stored)
optical disk drive (i.e. DVD-player, DVD-burner, Blu ray player, blu ray burner)
OS=operating system - required for running, organize and administrating the server
"e.g. S26361-F1234-E240" ordercode with "E" means it is either integrated into to Server (CPU, Mem, ..) or integrated in the
shipping box /Keyboard, Mouse, ..)
"e.g. S26361-F1234-L240" ordercode with "L" means, the part will be shipped with extra package, may be as well with extra
shipment
PRIMERGY TX2550 M7
System configurator and
order information guide
PCI Riser left (CPU2)
PCI Riser right (CPU1)
PRIMERGY TX2550 M7 rear view
cnfgTX2550M7-20231117_scriptionPage 4 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
PRIMERGY TX2550 M7 front view with drives
The front views shown below represent all possible drive options; they do not represent the base units.
For information on base units and HD drive cage for each drive option, please see chapter “base” and "HD_cage"
3.5-inch hot plug SAS/SATA
4x HDDs/SSDs8x HDDs/SSDs12x HDDs/SSDs
2.5-inch hot plug SAS/SATA/NVMe
8x HDDs/SSDs16x HDDs/SSDs16x HDDs/SSDs + 8xHDDs/SSDs/NVMes
24x HDDs/SSDs24x HDDs/SSDs + 8xHDDs/SSDs/NVMes
recommended components for TX2550 M7
Independant Mode installation
iRMC S6 advanced pack
Modular PSU 900W Titanium hot plug
#
1x
1x
2x
cnfgTX2550M7-20231117_scriptionPage 5 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
Chapter 1 - base unit
Start
Power supply units & cooling:
PRIMERGY TX2550 M7 offers bays for 2x (1x optional hot plug redundant) power supply units of 500W, 900W, 1600W, 2400W with up to 96% efficiency. 2200W with up to 94%
efficiency. Rack options ex factory or via retrofit upgrade with rack conversion kit.
Server Management:
iRMC S6 (integrated Remote Management Controller) on-board with dedicated Service LAN-port and integrated graphics controller. With onboard indicators and controls to easily
highlight failed components via LEDs displayed during service even without mains connection by simply pressing
the "indicate CSS" button. Optional ServerView Suite software incl. ServerView Installation Manager, Server View Remote Management and tools.
Platform:
Fujitsu Systemboard D3985-A made in Taiwan based on Chipset Intel® C741, up to two Xeon (Sapphire Rapids) series CPUs, four Intel® UltraPath
Interconnect (Intel® UPI) point-to-point links and onboard RAID 0/1 6Gbit/s available for up to 8x SATA drives.
16GB SD card as default
Slots: 6x PCIe slots are on board, with optional riser card up to 10x PCIe slots are available:
> 6x PCIe slots onboard, low profile, 167mm lengh, supported with first/second CPU:
Slot 1: PCIe-Gen5 x16
Slot 2: PCIe-Gen5 x16 (occupied in configurations with optional riser card)
Slot 3: PCIe-Gen5 x16 (occupied in configurations with optional riser card)
Slot 8: PCIe-Gen5 x16
Slot 9: PCIe-Gen5 x16 (occupied in configurations with optional riser card)
Slot 10: PCIe-Gen5 x16 (occupied in configurations with optional riser card)
> Optional full height riser card on PCIe slot 2/3/9/10 offers 4x additional PCIe slots, full height, 252mm and 1x PCI4/5 , with first/second CPU:
Slot 4/11: PCIe-Gen4/5 x16
Slot 5/12: PCIe-Gen4/5 x16
> Optional full height riser card on PCIe slot 2/3/9/10 offers 8x additional PCIe slots, full height, 252mm and 1x PCI4/5, with first/second CPU:
Slot 4/11: PCIe-Gen4/5 x8
Slot 5/12: PCIe-Gen4/5 x8
Slot 6/13: PCIe-Gen4/5 x8
Slot 7/14: PCIe-Gen4/5 x8
System RAM:
16x slots for DDR5-4800MHz RAM modules available (8x RAM modules per CPU). Memory speed depends on CPU and configuration.
LAN: 2x 1Gb LAN onboard;
Interfaces at rear sideInterfaces at front side
- 1x optional RS-232-C (serial port, 9 pin)- 2x USB 3.1 Gen1 (no USB wakeup)
- 2x LAN Rj45 (additional 2x RJ45 optionally available)
Interfaces internal
- 1x service LAN RJ45 (1 Gbit)
- 1x USB 3.1 Gen1 for backup devices
- 1x VGA (15 pins)
- 2x M.2
- 4x USB 3.1 Gen1
- 1x connector for TPM, 1x microSD card slot
Tower base units;
-Low noise hotplug fans
-up to 6 PCIe slots
Tower base units;
-High performance hotplug fans
-up to 10 PCIe slots
Rack base units;
-High performance hotplug fans
-up to 10 PCIe slots
C
h
o
o
s
e
o
n
e
b
a
s
e
u
n
i
t
PY TX2550 M7 Tower, 4x3.5" basic
PYT2557T3N
Tower server, expandable to 8x3.5";
Not support GPGPU
PY TX2550 M7 Tower, 8x3.5"
PYT2557TAN
Tower server, expandable to 12x3.5";
PY TX2550 M7 Rack, 8x3.5"
PYT2557R3N
Rack server, expandable to 12x3.5";
PY TX2550 M7 Tower, 8x2.5" basic
PYT2557T2N
Tower server, not expandable;
Not support GPGPU
PY TX2550 M7 Tower, 8x2.5"
PYT2557TBN
Tower server, expandable to 24x2.5";
PY TX2550 M7 Rack, 8x2.5"
PYT2557R2N
Rack server, expandable to 24x2.5";
PY TX2550 M7 Tower 4x3.5' basic and PY
TX2550 M7 Tower 8x2.5' basic do not support
Advanced Thermal design(ATD) options!
PY TX2550 M7 Tower, 24x2.5"
PYT2557TCN
Tower server, expandable to 32x2.5";
PY TX2550 M7 Rack, 24x2.5"
PYT2557RAN
Rack server, expandable to 32x2.5";
APRIMECENTER Rack
cnfgTX2550M7-20231117_sePage 6 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
Chapter 2 - Rack architecture
APRIMECENTER Rack
S26361-F2735-E111 PYBRRL6PY-RC18
No Rackmount-KitPY-RRL6
Rack conversion kit
No rackmount. Upgrade later possible
Rack Mount Kit F2-C S7 LV
Contains all necessary parts to convert PRIMERGY TX2550
with L-part
telescopic drop-in rail, full extractical, supports 1-
M7 Tower Server into a Rack server.
max. 1x per system
hand-mounting
Rackmount Kit ex factory
Rack mounting kit has to be ordered seperately.
> 1 pair of vario carrier with variable length & quick
release lever support
> 1 pair of telescopic drop-in rails with Cable
Management Arm (CMA) adapter
1x per system
S26361-F2735-E82
S26361-F2735-L82
2U cable management arm (CMA) for
2U server or higher
for mounting in symmetrical
PRIMECENTER M2/M1 racks
- 1 bracket PC M2/M1 Rack
1x per system
S26361-F1647-E302
Installation ex factory in a PRIMECENTER Rack
The installation service is to be ordered once per installable server/storage
Fujitsu will deliver the PRIMERGY mounted in a Rack System and all wired
subsystem, in order to get the server/storage subsystem mounted into the
connections are tested with PRIMECENTER rack - Systems and components will be
racks. In case of the 46 U PCR S2 this service has to be ordered, to get the
delivered installed in the rack
mounting kits and the cables installed.
max. 1x per System
B
cnfgTX2550M7-20231117_sePage 7 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
Chapter 3 - CPU
B
General Discription
There are 2 processor sockets available. Please configure 1 or 2 Processors.
>> All processors have to be the same type.
>> With one processor iRMC, 3x PCIe low profile slots(Up to 1x PCIe low profile + 4x PCIe full height) and 8x DIMM slots are available
>> With two processors all 16x DIMM slots, 6x PCIe low profile slots are available. Up to 2x PCIe low profile + 8x PCIe full height.
>> To configure 2nd CPU an additional cooler kit is required.
* HT = Hyper Threading
Notice
** Base Unit is not including CPUs. Minimum 1x CPU is required to be configured in one base unit.
** Maximum 2x CPUs are allowed to be configured in one base unit. Only 1 type of CPU can be configured in one base unit.
**CPU: PYBCP65XR, PYBCP65XS and PYBCP65X1 are not allowed to be configured 2x CPUs
CPU Group for
Thermal condition
Xeon Bronze 34xx - Mainline, 1 socket configuration only(BTO)(Loose delivery)
64-bit Intel Xeon processor supporting HT*, DDR5 @ 4000 MT/s
Xeon Bronze 3408U 8C 1.8GHz 125WPYBCP65XR-A
MCC
Xeon Silver 44xx - Mainline, 2 socket scalability(BTO)(Loose delivery)
64-bit Intel Xeon processor supporting HT*, DDR5 @ 4000 MT/s & UPI Bus (2UPI) @ 16 GT/s
Xeon Silver 4410Y 12C 2.0GHz 150W Speed Select TechnologyPYBCP66XGPY-CP66XGA
MCC
Xeon Silver 4416+ 20C 2.0GHz 165WPYBCP66XHPY-CP66XHB
MCC
Xeon Gold 54xx - Mainline/Performance Optimized, 1 socket configuration only(BTO)(Loose delivery)
64-bit Intel Xeon processor supporting HT*, DDR5 @ 4400 MT/s
Xeon Gold 5412U 24C 2.1GHz 185WPYBCP65XS-B
MCC
Xeon Gold 54xx - Mainline/Performance Optimized, 2 socket scalablity(BTO)(Loose delivery)
64-bit Intel Xeon processor supporting HT*, DDR5 @ 4400 MT/s & UPI Bus (3UPI) @ 16 GT/s
Xeon Gold 5415+ 8C 2.9GHz 150WPYBCP65XTPY-CP65XTA
MCC
Xeon Gold 5418Y 24C 2.0GHz 185W Speed Select TechnologyPYBCP65XWPY-CP65XWB
MCC
Xeon Gold 5420+ 28C 2.0GHz 205WPYBCP65XXPY-CP65XXB
MCC
Xeon Gold 64xx - Mainline/Performance Optimized, 1 socket configuration only(BTO)(Loose delivery)
64-bit Intel Xeon processor supporting HT*, DDR5 @ 4800(1DPC) / 4400(2DPC) MT/s
Xeon Gold 6414U 32C 2.0GHz 250WPYBCP65X1-C
XCC
Xeon Gold 64xx - Mainline/Performance Optimized, 2 socket scalability(BTO)(Loose delivery)
64-bit Intel Xeon processor supporting HT*, DDR5 @ 4800(1DPC) / 4400(2DPC) MT/s & UPI Bus (3UPI) @ 16 GT/s
Xeon Gold 6426Y 16C 2.5GHz 185W Speed Select TechnologyPYBCP66X2PY-CP66X2B
MCC
Xeon Gold 6430 32C 2.1GHz 270W (DDR5 @ 4400(1DPC/2DPC)) PYBCP65X2PY-CP65X2D
XCC
Xeon Gold 6434 8C 3.7GHz 195WPYBCP66X4PY-CP66X4B
MCC
Xeon Gold 6438Y+ 32C 2.0GHz 205W Speed Select TechnologyPYBCP66X8PY-CP66X8B
MCC
Xeon Gold 6442Y 24C 2.6GHz 225W Speed Select TechnologyPYBCP66X9PY-CP66X9C
MCC
Xeon Gold 6448Y 32C 2.1GHz 225W Speed Select TechnologyPYBCP66XCPY-CP66XCC
MCC
Xeon Platinum 84xxH - IMDB/Analytics Workload Optimized, 8 socket scalability(BTO)(Loose delivery)
64-bit Intel Xeon processor supporting HT*, DDR5 @ 4800(1DPC) / 4400(2DPC) MT/s & UPI Bus (4UPI) @ 16 GT/s
Xeon Platinum 8444H 16C 2.9GHz 270WPYBCP65X4PY-CP65X4D
XCC
Xeon Platinum 8450H 28C 2.0GHz 250W Speed Select TechnologyPYBCP65X6PY-CP65X6C
XCC
Xeon - Storage & HCI Workload Optimized, 2 socket scalability(BTO)(Loose delivery)
64-bit Intel Xeon processor supporting HT*, DDR5 @ 4800(1DPC) / 4400(2DPC) MT/s & UPI Bus (3UPI) @ 16 GT/s
Xeon Gold 5416S 16C 2.0GHz 150W (DDR5 @ 4400(1DPC/2DPC)) Speed Select TechnoPYBCP65XUPY-CP65XUA
MCC
Xeon Gold 6454S 32C 2.2GHz 270W Speed Select TechnologyPYBCP65X3PY-CP65X3D
XCC
Xeon - Long-Life Use (IOT) Workload Optimized, 2 socket scalability(BTO)(Loose delivery)
64-bit Intel Xeon processor supporting HT*, DDR5 @ 4000 MT/s & UPI Bus (2UPI) @ 16 GT/s
Xeon Silver 4410T 10C 2.7GHz 150W Speed Select TechnologyPYBCP66XFPY-CP66XFA
MCC
Notice
2CPU configuration require to order 2nd CPU cooler kit
CPU Cooler kit(BTO)(Loose delivery)
2nd CPU Cooler kit for Basic model***PYBTKCPC85-
2nd CPU Cooler kit****PYBTKCPC86-
CPU cooler kit for loose delivery CPU for Basic model***-PY-TKCPC85
CPU cooler kit for loose delivery CPU****-PY-TKCPC86
*** For PYT2557T3N/PYT2557T2N
**** For PYT2557TAN/PYT2557TBN/PYT2557TCN/PYT2557R3N/PYT2557R2N/PYT2557RAN
C
cnfgTX2550M7-20231117_UPage 8 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
Chapter 4 - DDR5 System memory
C
Each CPU offers 8 Slots for DDR5 Memory Modules organised in 1 Banks and 8 Channels with 4 Memory Controllers (2 Channels each).
If you need more than 8 Slots you have to configure 2nd CPU.
Depending on the amount of memory configured you can decide between the Normal Memory RAS mode or the Mirroring Memory RAS Mode.
There are different kinds of DDR5 Memory Modules available: RDIMM x4, RDIMM x8, RDIMM 3DS x4.
Mix of different memories is not allowed.
Supported memory capacities per CPU:
Up to 2TB using DDR5 RDIMM (8x 256GB DDR5 RDIMM 3DS)
Supported memory capacities per System (with 2CPU configuration):
Up to 4TB using DDR5 RDIMM (16x 256GB DDR5 RDIMM 3DS)
The memory speed depends on configuration restricted by the CPU SKU (max. 4800 MT/s).
DDR5 memory is operated at 1.1V
Memory Mode ; One of followig memory modes must be selected.
Independent ModeRequires 1, 2, 4, 6 or 8 Memory Modules per CPU1x per CPUPYBMMD2
Independent Mode required to be the best performance.
ADDDC Sparing is available in case system configured by DDR5 xRx4 DIMM only.
Mirroring ModeRequires 8 Memory Modules per CPU1x per CPUPYBMMC4
BIOS preconfiguration for Mirroring mode. 8x identical memory modules are always equipped on same bank across all channels to use the mirrored channel mode. Half of the
modules contain active data, the remaining modules contain mirrored data.
min/max 1x per CPU; max 2x for System
DDR5 DIMM only configuration section
Min 1x DIMM per CPU is required. Any Mix of RDIMMx8, RDIMMx4, RDIMM 3DS is not allowed.
DDR5 Registered DIMM 4800MHz 1R/2R x8
16GB (1x16GB) 1Rx8 DDR5-4800 R ECC
max 8x per CPUPYBME16SLPY-ME16SL
32GB (1x32GB) 2Rx8 DDR5-4800 R ECC
max 8x per CPUPYBME32SLPY-ME32SL
max 8x per CPU; max 16x for System
DDR5 Registered DIMM 4800MHz 1R/2R x4
32GB (1x32GB) 1Rx4 DDR5-4800 R ECC
max 8x per CPUPYBME32SL2PY-ME32SL2
64GB (1x64GB) 2Rx4 DDR5-4800 R ECC
max 8x per CPUPYBME64SLPY-ME64SL
max 8x per CPU; max 16x for System
DDR5 Registered DIMM 4800MHz 3DS 4R/8R x4
128GB (1x128GB) 4Rx4 DDR5-4800 R 3DS ECC
max 8x per CPUPYBME12SLPY-ME12SL
256GB (1x256GB) 8Rx4 DDR5-4800 R 3DS ECC
max 8x per CPUPYBME25SLPY-ME25SL
max 8x per CPU; max 16x for System
D
cnfgTX2550M7-20231117_MPage 9 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
Detailed information
RAS feature
ECC
SDDC
ADDDC Sparing
Mirroring channel
Memory Mode
Normal Mode/Mirroring Mode
Normal Mode/Mirroring Mode
Normal Mode
Mirroring Mode
RDIMM
x8
yes
no
no
yes
RDIMM
LRDIMM
x4
yes
yes
yes
yes
BIOS setting
always enabled.
always enabled in case x4 DIMM conifugred.
disabled as default.
enabled in case Mirroring Mode ordered.
Configuration
Min. Memory
Max. Memory per CPU
Max. Memory per System
DIMM
1 Module / CPU
8 Module / CPU
16 Modules / CPU
32 Modules / System
CPU
with one CPU
with one CPU
with two CPU
with two CPU
Normal Mode
16GB: 16GB x1
-
2TB: 256GB x8
4TB: 256GB x16
Available Capacity
Mirroring Mode
-
64GB: 16GBx8x50%
1TB: 256GBx8x50%
2TB: 256GBx16x50%
The memory sockets on the Systemboards are color coded
C
h
a
n
n
e
l
G
C
h
a
n
n
e
l
A
C
h
a
n
n
e
l
B
C
h
a
n
n
e
l
C
C
h
a
n
n
e
l
D
Bank Iblack sockets
iMC0iMC1
CPU
iMC2iMC3
Normal Mode population DDR5 DIMM only
Normal Mode requires 1x, 2x, 4x, 6x or 8x DIMM configuration per CPU.
for 2x or more than 2x DIMM configuration,
Between Chanel A-E/C-G/B-F/D-H, balanced configuration is required. same bank of each chanel need to be populatd.
Between Chanel A-C-E-G/B-D-F-H, each chanel capacity need to be same if DIMM poputated in each Chanel.
1 DIMMs for 1CPU1 DIMMs for 1CPU
C
h
a
n
n
e
l
G
C
h
a
n
n
e
l
H
C
h
a
n
n
e
l
E
C
h
a
n
n
e
l
F
C
h
a
n
n
e
l
G
C
h
a
n
n
e
l
A
C
h
a
n
n
e
l
B
C
h
a
n
n
e
l
C
C
h
a
n
n
e
l
D
C
h
a
n
n
e
l
H
C
h
a
n
n
e
l
A
C
h
a
n
n
e
l
B
C
h
a
n
n
e
l
C
C
h
a
n
n
e
l
D
Data
iMC0iMC1
CPU
1 DIMMs for 1CPU1 DIMMs for 1CPU
iMC2iMC3iMC0iMC1
CPU
Data
iMC2iMC3
C
h
a
n
n
e
l
G
C
h
a
n
n
e
l
G
C
h
a
n
n
e
l
A
C
h
a
n
n
e
l
B
C
h
a
n
n
e
l
C
C
h
a
n
n
e
l
D
C
h
a
n
n
e
l
H
C
h
a
n
n
e
l
A
C
h
a
n
n
e
l
B
C
h
a
n
n
e
l
C
C
h
a
n
n
e
l
D
Data
iMC0iMC1
CPU
iMC2iMC3iMC0iMC1
CPU
iMC2
Data
iMC3
cnfgTX2550M7-20231117_M
C
h
a
n
n
e
l
H
C
h
a
n
n
e
l
E
C
h
a
n
n
e
l
E
C
h
a
n
n
e
l
F
C
h
a
n
n
e
l
F
C
h
a
n
n
e
l
H
C
h
a
n
n
e
l
E
C
h
a
n
n
e
l
E
C
h
a
n
n
e
l
F
C
h
a
n
n
e
l
F
Page 10 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
2 DIMMs for 1CPU
2x identical memory modules need to be populated.
2 DIMMs for 1CPU
2x identical memory modules need to be populated.
C
h
a
n
n
e
l
G
C
h
a
n
n
e
l
G
C
h
a
n
n
e
l
A
C
h
a
n
n
e
l
B
C
h
a
n
n
e
l
C
C
h
a
n
n
e
l
D
C
h
a
n
n
e
l
H
C
h
a
n
n
e
l
A
C
h
a
n
n
e
l
B
C
h
a
n
n
e
l
C
C
h
a
n
n
e
l
D
Data
iMC0iMC1
CPU
4 DIMMs for 1CPU
4x identical memory modules need to be populated.
iMC2
Data
iMC3iMC0
Data
iMC1
CPU
Data
iMC2iMC3
6 DIMMs for 1CPU
6x identical memory modules need to be populated.
C
h
a
n
n
e
l
G
C
h
a
n
n
e
l
G
C
h
a
n
n
e
l
A
C
h
a
n
n
e
l
B
C
h
a
n
n
e
l
C
C
h
a
n
n
e
l
D
C
h
a
n
n
e
l
H
C
h
a
n
n
e
l
A
C
h
a
n
n
e
l
B
C
h
a
n
n
e
l
C
C
h
a
n
n
e
l
D
Data
iMC0
Data
iMC1
CPU
Data
iMC2
Data
iMC3
Data
iMC0
Data
iMC1
DataData
iMC2
CPU
DataData
iMC3
6 DIMMs for 1CPU
6x identical memory modules need to be populated.
6 DIMMs for 1CPU
6x identical memory modules need to be populated.
C
h
a
n
n
e
l
G
C
h
a
n
n
e
l
G
C
h
a
n
n
e
l
A
C
h
a
n
n
e
l
B
C
h
a
n
n
e
l
C
C
h
a
n
n
e
l
D
C
h
a
n
n
e
l
H
C
h
a
n
n
e
l
A
C
h
a
n
n
e
l
B
C
h
a
n
n
e
l
C
C
h
a
n
n
e
l
D
Data
iMC0
DataData
iMC1
CPU
Data
iMC2
Data
iMC3
Data
iMC0
DataData
iMC1
DataData
iMC2
CPU
Data
iMC3
Data
6 DIMMs for 1CPU
6x identical memory modules need to be populated.
8 DIMMs for 1CPU
8x identical memory modules need to be populated.
C
h
a
n
n
e
l
G
C
h
a
n
n
e
l
G
C
h
a
n
n
e
l
A
C
h
a
n
n
e
l
B
C
h
a
n
n
e
l
C
C
h
a
n
n
e
l
D
C
h
a
n
n
e
l
H
C
h
a
n
n
e
l
A
C
h
a
n
n
e
l
B
C
h
a
n
n
e
l
C
C
h
a
n
n
e
l
D
Data
iMC0
Data
iMC1
Data
iMC2
CPU
DataData
iMC3
DataData
iMC0
DataData
iMC1
DataData
iMC2
CPU
DataData
iMC3
Data
Mirroring Mode population DDR5 DIMM only
Mirroring Mode requires 8x or 16x DIMM configuration per CPU.
in addition to Normal Mode Memory population rules,
Between Chanel A-B/C-D/E-F/G-H, identical DIMM need to be populated in same bank.
8 DIMMs for 1CPU
C
h
a
n
n
e
l
G
C
h
a
n
n
e
l
A
C
h
a
n
n
e
l
B
C
h
a
n
n
e
l
C
C
h
a
n
n
e
l
D
DataMirror
iMC0
DataMirror
iMC1
CPU
DataMirror
iMC2
DataMirror
iMC3
cnfgTX2550M7-20231117_
C
h
a
n
n
e
l
H
C
h
a
n
n
e
l
E
C
h
a
n
n
e
l
F
RAM
C
h
a
n
n
e
l
H
C
h
a
n
n
e
l
E
C
h
a
n
n
e
l
E
C
h
a
n
n
e
l
F
C
h
a
n
n
e
l
F
C
h
a
n
n
e
l
H
C
h
a
n
n
e
l
E
C
h
a
n
n
e
l
E
C
h
a
n
n
e
l
F
C
h
a
n
n
e
l
F
C
h
a
n
n
e
l
H
C
h
a
n
n
e
l
E
C
h
a
n
n
e
l
E
C
h
a
n
n
e
l
F
C
h
a
n
n
e
l
F
C
h
a
n
n
e
l
H
C
h
a
n
n
e
l
E
C
h
a
n
n
e
l
E
C
h
a
n
n
e
l
F
C
h
a
n
n
e
l
F
Page 11 of 43
The different GPU mixed configuration
does NOT support.
The different GPU mixed configuration
does NOT support.
These combination between RTX series and these Adapters(S26361-F4066-E12/L12,
S26361-F4066-E13/L13) are ristriction. It will be avaiable in 09.2023
FPGA Card T.B.D. to be available from GA
PRIMERGY TX2550 M7
System configurator and
order information guide
Chapter 6 - HD drive cage
F
HD drive cage is a metal box providing bays for 3.5" HDDs or 2.5" HDDs/SSDs/PCIe-SSDs. Choose out of the
following HD cage upgrade kits, depending on pre-selected TX2550 M7 base unit and the targeted configuration. Each upgrade kit contains all relevant
parts such as metal cage, backplane, cables and mounting material.
Upgrade kits for the upper drive area require the completion of the mid drive area.
Up to 3x 1.6x5.25" bays are available in the upper drive area for an ODD and/or backup drive configurations; in the 12x3.5" configuration, a 9.5mm bay is
available for a slim ODD. Refer to sections "ODD" and "backup" for details.
Upgrade kits are available either ex-factory (E-codes) or as loose delivery party (L-codes).
RAID configurations are recommendations; refer to section "RAID" for available options.
Preferred slots for controller assignementGeneral drive numbering scheme
Rear side view (incl. riser card option; refer to sheet "Description" for details)
TX2550 M7 front views of expandable base units and corresponding HD drive cage options:
If you change channel for HBA- or RAID-Controller as loose delivery, SAS cable need to be changed.
Option BPY-CBS085SAS cable for CP2100-8i
Option CPY-CBS086SAS cable for CP6xx/EP6xx/EP32xx
Base Unit
PY TX2550 M7 Tower, 4x3.5" basic
PYT2557T3N
RAID configuration1x HBA- or RAID-Controller. Refer to section "RAID" for options. Onboard SATA (max. 8x disks)
ODD / Backup3x 1.6x5.25" bays are available for an optical and/or backup drives in the upper drive area.
Upgrade kit for 4x3.5" HDD
PYBBA34SAPY-BA34SA
Upgrade kit for 4x3.5" HDD, mounted in the mid
drive area
Base Unit
PY TX2550 M7 Tower, 8x3.5"PY TX2550 M7 Rack, 8x3.5"
PYT2557TANPYT2557R3N
RAID configuration1x HBA- or RAID-Controller. Refer to section "RAID" for options. onboard SATA(Max. qty. for Disk is eight.)
if no upper drive area is installed, the below can be selected.
ODD / Backup3x 1.6x5.25" bays are available for an optical and/or backup drives in the upper drive area.
HD cage upgrades for upper drive area
Upgrade kit for 4x3.5" HDD
PYBBA34SBPY-BA34SB
Upgrade kit for 4x3.5" HDD, mounted in the
upper drive area,
incl. 40x SAS Expander
1x 9.5mm bay is available for a slim optical drive
in the upper drive area.
Note! This option requires 1x PRAID/HBA per
Base unit
RAID configuration1x HBA- or RAID-Controller. Refer to section "RAID" for options.
ODD / Backup1x 9.5mm bay is available for a slim optical drive in the upper drive area.
Base Unit
PY TX2550 M7 Tower, 8x2.5" basic
PYT2557T2N
RAID configuration1x HBA- or RAID-Controller. Refer to section "RAID" for options. onboard SATA(Max. qty. for Disk is eight.)
ODD / Backup3x 1.6x5.25" bays are available for an optical and/or backup drives in the upper drive area.
cnfgTX2550M7-20231117__cagePage 14 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
Base unit
PY TX2550 M7 Tower, 8x2.5"PY TX2550 M7 Rack, 8x2.5"
PYT2557TBNPYT2557R2N
RAID configuration1x HBA- or RAID-Controller. Refer to section "RAID" for options. onboard SATA(Max. qty. for Disk is eight.)
if no upper drive area is installed, the below can be selected.
ODD / Backup3x 1.6x5.25" bays are available for an optical and/or backup drives in the upper drive area.
HD cage upgrades
Upgrade kit for 8x2.5" HDDUpgrade kit for 8x2.5" HDD
PYBBA28SQPY-BA28SQPYBBA28SRPY-BA28SR
Upgrade kit for 8x2.5" HDD, mounted in the mid Upgrade kit for 8x2.5" HDD, mounted in the mid
drive area,drive area,
for connect 16port RAID option
incl. 40x SAS Expander
Note! This option requires 1x 16-channel
PRAID/HBA
Note! This option requires 1x PRAID/HBA
Upgrade kit for the upper drive area
Please refer to “Upgrade kit for the upper drive area with PYT2557TBN/ PYT2557R2N/ PYT2557TCN/ PYT2557RAN
Base unit
PY TX2550 M7 Tower, 24x2.5"PY TX2550 M7 Rack, 24x2.5"
PYT2557TCNPYT2557RAN
Including 40x SAS Expander!
RAID configuration1x HBA- or RAID-Controllers. Refer to section "RAID" for options.
ODD / Backup3x 1.6x5.25" bays are available for an optical and/or backup drives in the upper drive area.
HD cage upgrades
Upgrade kit for the upper drive area
Please refer to “Upgrade kit for the upper drive area with PYT2557TBN/ PYT2557R2N/ PYT2557TCN/ PYT2557RAN
cnfgTX2550M7-20231117__cagePage 15 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
The mix configuration information
Upgrade kit for the upper drive area with PYT2557TBN/ PYT2557R2N/ PYT2557TCN/ PYT2557RAN
Only one of them can be selected.
Upgrade kit for 8x2.5" HDD
PYBBA28SS
8x2.5"
PY-BA28SS
Upgrade kit for 8x2.5" HDD(SAS4)8x2.5" combo HDD
Note!
This option requires 2x CPUs.
This option requires min. 1x 24Gb/s PRAID/HBA
In total, 2x PRAID/ HBA are allowed (1x for bottom / mid area,
1x for upper area). Choose from the options below:
PYBBA28ST
[Option 1] – Choose two of the following:
- 1x for bottom / mid area :
PRAID EP 325x-xi [PYBSR4MA1L/PY-
SR4MA1/PYBSR4MA2L/PY-SR4MA2/PYBSR4MA3L/PY-
SR4MA3],
or PSAS CP 2200-16i [PYBSC4MA1L/PY-SC4MA1]
or PSAS CP 2100-8i [PYBSC3MA2L/PY-SC3MA2].
- 1x for upper area :
PRAID EP 325x-xi [PYBSR4MA1L/PY-
SR4MA1/PYBSR4MA2L/PY-SR4MA2/PYBSR4MA3L/PY-
SR4MA3],
or PSAS CP 2200-16i [PYBSC4MA1L/PY-SC4MA1]
PY-BA28ST
[Option 2] – Choose two of the following:
- 1x for bottom / mid area :
PSAS CP600i[PYBSC4FAL/PY-SC4FA],
or PRAID CP600i[PYBSR4FAL/PY-SR4FA],
or PRAID EP740i[PYBSR4C71L/PY-SR4C71],
or PRAID EP6x0i[PYBSR4C63L/PY-SR4C63/PYBSR4C6L/PY-
SR4C6]
- 1x for upper area :
Upgrade kit for 1-4 x2.5" PCIe SSD SFF w/
PYBBA24PJ
8x2.5" combo HDD
onBoard
PY-BA24PJ
Upgrade kit for 1-4 x2.5" PCIe SSD SFF w/
PYBBA24PK
8x2.5" combo HDD
PRAID
Note!
PY-BA24PK
This option requires 1x PRAID for NVMe.
upgrade kit for 5-8 x2.5" PCIe SSD SFF w/
PYBCBE024
Note!
onBoardThis option requires 2x CPUs.
PY-CBE024
This option requires PYBBA24PJ.
Upgrade kit for 5-8 x2.5" PCIe SSD SFF w/ Note!
PRAID
PYBCBE025
This option requires 2x CPUs.
PY-CBE025
This option requires another PRAID for NVMe.
This option requires PYBBA24PK.
RAID configurationHBA- or RAID- or Retimer-Controllers. Refer to section "RAID" for options.
ODD / Backup
1x 1.6x5.25" bay is available for an optical or backup drive in the upper drive area.
Note! One of LTO and ODD can be selected.
G
cnfgTX2550M7-20231117__cagePage 16 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
Chapter 7 - SAS / RAID Controller
G
FH PCIe card requires FH PCIe riser card. Please refer to ''Chapter 14 - PCI riser card'.
onboard SATA controller with SW-RAID
onboard controller for SATA HDD or SSD drives
6Gb/s SATAIntel VROC (SATA RAID) based on chipset
BIOS version R1.6.0 or later is required to use Intel VROC (SATA RAID)
No CacheSW-RAID 0, 1, 102xonboard, included
intenal HBA and RAID controller, no 2nd Level cache
internal RAID / HBA controllers for SAS, SATA HDD or SSD drives
RAID 0, 1, 10
PRAID CP600i LPNo Cache
8 ports 3, 6 & 12Gb/s SAS/SATA HDD/SSD, supports up to 8 drives without expander
supports SED (Self Encrypting Drives)
requires 1x LP PCIe 4.0 x8 (int.) slot, based on LSI SAS3808
HBA, no RAID
PSAS CP600i LPNo Cache
16 ports 3, 6 & 12Gb/s SAS/SATA HDD/SSD, supports up to 16 drives without expander
limitation: supports up to 30 drives only with expander
requires 1x LP PCIe 4.0 x8 (int.) slot, based on LSI SAS3816; IT FW stack without RAID functionality
PYBSR4FAL
PY-SR4FA
PYBSC4FALPY-SC4FA
internal RAID / HBA controllers for SAS, SATA HDD or SSD drives
HBA + RAID 0, 1, 10, 5PYBSC4MA1LPY-SC4MA1
No Cache
PSAS CP 2200-16i LP available from 2024/03
16 ports 6, 12 & 24Gb/s SAS/SATA HDD/SSD, supports up to 16 SAS/SATA drives without expander
(the configuration for up to 4 x4 NVMe drives requires a different order number, please see below)
supports SED (Self Encrypting Drives)
requires 1x LP PCIe 4.0 x8 (int.) slot
* max. 2x, when Upgrade kit for 8x2.5" HDD(SAS4): PYBBA28ST is ordered
(FYI: PYBSC4MA1L and PYBSC4MA2(L) are identical products. The 2nd Order number was only introduced for explicite ordering and cabling)
HBA + RAID 0, 1, 10, 5
PSAS CP 2100-8i LPNo Cache
8 ports 3, 6 & 12Gb/s SAS/SATA HDD/SSD, supports up to 8 devices without expander
requires 1x LP PCIe 3.0 x8 (int.) slot
PYBSC3MA2LPY-SC3MA2
internal RAID / HBA controllers for PCIe SSD drives
HBA + RAID 0, 1, 10, 5PYBSC4MA2
No Cache
PSAS CP 2200-16i NVMe FH
available from 2024/03
PY-SC4MA1
HBA + RAID 0, 1, 10, 5PYBSC4MA2L
No Cache
PSAS CP 2200-16i NVMe LP
available from 2024/03
up to 4 x4 NVMe drives are supported. (the configuration for SAS/SATA only requires a different order number, please see above)
requires 1x FH or LP PCIe 4.0 x8 (int.) slot
(FYI: PYBSC4MA1L and PYBSC4MA2(L) are identical products. The 2nd Order number was only introduced for explicite ordering and cabling)
internal RAID controller with 2nd Level cache
internal RAID controllers for SAS, SATA HDD or SSD drives
PYBSR4C71LPY-SR4C71
PRAID EP740i LP available from 2024/07
4GB Cache
RAID 0, 1, 10, 5, 50, 6, 60
16 ports 6, 12 & 24Gb/s SAS/SATA HDD/SSD, supports up to 16 SAS/SATA drives without expander
(the configuration for up to 4 x4 NVMe drives requires a different order number, please see below)
supports SED (Self Encrypting Drives)
requires 1x LP PCIe 4.0 x8 (int.) slot, based on LSI SAS4116
* max. 2x, when Upgrade kit for 8x2.5" HDD(SAS4): PYBBA28ST is ordered
(FYI: PYBSR4C71L and PYBSR4C72(L) are identical products. The 2nd Order number was only introduced for explicite ordering and cabling)
internal RAID controllers for SAS, SATA HDD or SSD drives
PRAID EP640i LP4GB Cache
RAID 0, 1, 10, 5, 50, 6, 60
8 ports 3, 6 & 12Gb/s SAS/SATA HDD/SSD, supports up to 8 drives without expander
supports SED (Self Encrypting Drives)
requires 1x LP PCIe 4.0 x8 (int.) slot, based on LSI SAS3908
PYBSR4C63LPY-SR4C63
PRAID EP680i LP8GB CachePYBSR4C6LPY-SR4C6
RAID 0, 1, 10, 5, 50, 6, 60
16 ports 3, 6 & 12Gb/s SAS/SATA HDD/SSD, supports up to 16 SAS/SATA drives without expander
(the configuration for up to 4 x4 NVMe drives requires a different order number, please see below)
supports SED (Self Encrypting Drives)
requires 1x LP PCIe 4.0 x8 (int.) slot, based on LSI SAS3916
(FYI: PYBSR4C6L and PYBSR4C62(L) are identical products. The 2nd Order number was only introduced for explicite ordering and cabling)
optional Flash Backup Unit (FBU)
FBU option for PRAID EP6xx / EP7xx: Supercap securing the power supply of the RAID controller in case of
S26361-F4042-E155
power failure including cable with 55cm length
S26361-F4042-L110
cnfgTX2550M7-20231117_IDPage 17 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
internal RAID controllers for PCIe SSD drives
4GB CachePYBSR4C72
PRAID EP740i NVMe FH
available from 2024/07
RAID 0, 1, 10, 5, 50, 6, 60
PY-SR4C71
4GB CachePYBSR4C72L
PRAID EP740i NVMe LP
available from 2024/07
RAID 0, 1, 10, 5, 50, 6, 60
up to 4 x4 NVMe drives are supported. (the configuration for SAS/SATA only requires a different order number, please see above)
requires 1x FH or LP PCIe 4.0 x8 (int.) slot, based on LSI SAS4116
(FYI: PYBSR4C71L and PYBSR4C72(L) are identical products. The 2nd Order number was only introduced for explicite ordering and cabling)
optional Flash Backup Unit (FBU)
S26361-F4042-L110
FBU option for PRAID EP7xx: Supercap securing the power supply of the RAID controller in case of power
S26361-F4042-E155
failure including cable with 55cm length
internal RAID controllers for PCIe SSD drives
PRAID EP680i NVMe FH8GB CachePYBSR4C62
RAID 0, 1, 10, 5, 50, 6, 60
PY-SR4C6
PRAID EP680i NVMe LP8GB CachePYBSR4C62L
RAID 0, 1, 10, 5, 50, 6, 60
up to 4 x4 NVMe drives are supported. (the configuration for SAS/SATA only requires a different order number, please see above)
no FBU is allowed for this controller
requires 1x FH or LP PCIe 4.0 x8 (int.) slot, based on LSI SAS3916
(FYI: PYBSR4C6L and PYBSR4C62(L) are identical products. The 2nd Order number was only introduced for explicite ordering and cabling)
internal RAID controllers for SAS, SATA HDD or SSD drives
PRAID EP 3252-8i LP2GB Cache
RAID 0, 1, 10, 5, 50, 6, 60
PRAID EP 3254-8i LP4GB Cache
RAID 0, 1, 10, 5, 50, 6, 60
8 ports 6, 12 & 24Gb/s SAS/SATA HDD/SSD, supports up to 8 drives without expander
supports SED (Self Encrypting Drives)
requires 1x LP PCIe 4.0 x8 (int.) slot
* max. 2x, when Upgrade kit for 8x2.5" HDD(SAS4): PYBBA28ST is ordered
PYBSR4MA1L
PYBSR4MA2L
PY-SR4MA1
PY-SR4MA2
PRAID EP 3258-16i LP8GB CachePYBSR4MA3LPY-SR4MA3
RAID 0, 1, 10, 5, 50, 6, 60
16 ports 6, 12 & 24Gb/s SAS/SATA HDD/SSD, supports up to 16 SAS/SATA drives without expander
(the configuration for up to 4 x4 NVMe drives requires a different order number, please see below)
supports SED (Self Encrypting Drives)
requires 1x LP PCIe 4.0 x8 (int.) slot
* max. 2x, when Upgrade kit for 8x2.5" HDD(SAS4): PYBBA28ST is ordered
(FYI: PYBSR4MA3L and PYBSR4MA4(L) are identical products. The 2nd Order number was only introduced for explicite ordering and cabling)
optional Flash Backup Unit (FBU)
FBU option for PRAID EP 325x in rear PCIe Slot#1: Supercap securing the power supply of the RAID
controller in case of power failure without extension cable
FBU option for PRAID EP 325x in rear PCIe Slot#8: Supercap securing the power supply of the RAID
controller in case of power failure including cable with 46cm length
PYBFBM014
PYBFBM012
PY-FBM01
PY-FBM01
internal RAID controllers for PCIe SSD drives
PRAID EP 3258-16i NVMe FH8GB CachePYBSR4MA4
RAID 0, 1, 10, 5, 50, 6, 60
PY-SR4MA3
PRAID EP 3258-16i NVMe LP8GB CachePYBSR4MA4L
RAID 0, 1, 10, 5, 50, 6, 60
available from 2024/03
up to 4 x4 NVMe drives are supported. (the configuration for SAS/SATA only requires a different order number, please see above)
requires 1x FH or LP PCIe 4.0 x8 (int.) slot
(FYI: PYBSR4MA3L and PYBSR4MA4(L) are identical products. The 2nd Order number was only introduced for explicite ordering and cabling)
optional Flash Backup Unit (FBU) available from 2024/03
FBU option for PRAID EP 325x in rear PCIe Slot#3/#4/#8: Supercap securing the power supply of the RAID
PYBFBM012
controller in case of power failure including cable with 46cm length
PY-FBM01
FBU cannot be combined with Advanced Thermal design.
up to 3x FBU can be integrated per System
Group A and Group B cannot be mixed
Group A and Group C can be mixed
Group B and Group C can be mixed
Group AGroup B
PSAS CP600iPSAS CP 2100-8i
PSAS CP600i for LTOPSAS CP 2200-16i
PRAID CP600iPSAS CP 2200-16i NVMe
PRAID EP740iPSAS CP 2200-16i for LTO
PRAID EP740i NVMePRAID EP 3252-8i
PRAID EP640iPRAID EP 3254-8i
PRAID EP680iPRAID EP 3258-16i
PRAID EP680i NVMePRAID EP 3258-16i NVMe
Group C
PSAS CP600e
PRAID EP680e
cnfgTX2550M7-20231117_IDPage 18 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
H
external HBA controller, no 2nd Level cache
external HBA controllers for SAS HDD or SSD drives
HBA, no RAID
PSAS CP600e FHNo Cache
HBA, no RAID
PSAS CP600e LPNo Cache
16 ports 3, 6 & 12Gb/s SAS/SATA HDD/SSD, 4x SFF8644 (external Mini-SAS HD)
requires 1x FH or LP PCIe 4.0 x8 (int.) slot, based on LSI SAS3816
PYBSC4FAE
PYBSC4FAEL
PY-SC4FAE
external RAID controller with 2nd Level cache
external RAID controllers for SAS HDD or SSD drives
PRAID EP680e FH8GB CacheRAID 0, 1, 10, 5, 50, 6, 60
PRAID EP680e LP8GB CacheRAID 0, 1, 10, 5, 50, 6, 60
8 ports 3, 6 & 12Gb/s SAS/SATA HDD/SSD, 2x SFF8644 (external Mini-SAS HD)
supports SED (Self Encrypting Drives)
requires 1x FH or LP PCIe 4.0 x8 (int.) slot, based on LSI SAS3916
optional Flash Backup Unit (FBU)
FBU option for PRAID EP6xx: Supercap securing the power supply of the RAID controller in case of power
failure including cable with 55cm length
PYBSR4C6E
PYBSR4C6EL
PY-SR4C6E
S26361-F4042-E155S26361-F4042-L110
internal controller for PCIe SSD (NVMe SSD), no HW-RAID
internal controller for PCIe SSD (NVMe SSD)
PCIeIntel CPUNo Cache
optional Licence Activation Key for Intel VROC (VMD NVMe RAID)
No Cache
Intel VROC Upgrade Key Premium
Intel CPU
BIOS version R1.6.0 or later is required to use Intel VROC (VMD NVMe RAID)
* RAID 1 is only supported In VMware ESXi.
I
No HW-RAID
SW-RAID 0, 1, 10, 5 *
-
1x
onboard, included
PYBRLVR02PY-RLVR02
cnfgTX2550M7-20231117_IDPage 19 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
Chapter 8 - ODD optical disk drives
PRIMERGY TX2550 M7offers up to 3x 1.6” bays (located in the upper side of Tower-/ right side of Rack-server) for various ODD's and/or backup drives.
Depending on the HDD drive cage configuration there may be some or all of 1.6” bays already occupied;please find the number of availablebays in the chapter 6, "HD-cage", incl. further configuration details.
I1
12x 3.5" configuration
with 1x 9.5mm bay
I2
Configurations
with min. 1x free 1.6" bay
S26361-F3778-E1
S26361-F3778-L1
DVD-RW supermulti ultra slim
all formats, DUAL/DL, DVD-
RAM only W2K, W3K and
Linux
S26361-F3641-E6
S26361-F3641-L6
Blu-ray Triple Writer ultra slim
6x BD-RW, 8x DVD, 24x CD,
BD DL and all CD/DVD
formats
will be EOL in CQ2'24
S26361-F3266-E2
S26361-F3266-L2
DVD-ROM
DVD-ROM or CD-ROM
will be EOL in CQ2'24
S26361-F3267-E2
S26361-F3267-L2
DVD-RW supermulti SATA
all formats, DUAL/DL, DVD-
RAM only W2K, W3K and Linux
S26361-F3641-E8
S26361-F3641-L8
Blu-ray Triple Writer SATA
6x BD-RW, 8x DVD, 24x CD, BD
DL and all CD/DVD formats.
9.5mm ultra slim drive integrated
into a 5.25" bay.
9.5mm, black bezel
max. 1x per system
9.5mm, black bezel
max. 1x per system
1.6" * 5.25" black bezel
max. 1x per system
1.6" * 5.25" black bezel
max. 1x per system
9.5mm at 1.6" *5.25" black bezel
max. 1x per system
will be available in CQ2'24will be available in CQ2'24
PYBDV122PYBDR122
PY-DV122PY-DR122
DVD-ROMDVD-RW supermulti SATA
DVD-ROM or CD-ROMall formats, DUAL/DL, DVD-
RAM only W2K, W3K and Linux
9.5mm at 1.6" *5.25" black bezel
max. 1x per system
9.5mm at 1.6" *5.25" black bezel
max. 1x per system
J
cnfgTX2550M7-20231117_DPage 20 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
Chapter 9 - backup drives
With mostconfigurations the TX2550 M7 offers 3 x 1.6” bay in the accessible drives area located at the top of the Tower Server (or at the right side of the Rack) for various ODD and or backup drives.
Depending on the HDD drive configuration there may be some or all of these 1.6” bays already occupied-please find the number of availablebays and the size listed as point 3)at each of the drive
bundles. All bundles with limitations are highlighted with 2 exclamation marks in the front (e.g. "!! 1x 9.5mm ...")
J
Config. with min. 1x free 1.6" bay
SAS HBA card for Internal LTO drives
Note: In case SATA/SAS/NVMe with Raid card and PCI Riser rights(PYBPRE638/PY-PRE638/PYBPRE641/PY-PRE641/PYBPRE848/PY-PRE848/PYBPRE643/PY-
PRE643/PYBPRE645/PY-PRE645/PYBPRE851/PY-PRE851) exists, this can't be used.
SAS HBA Controller
PYBSC4FA2LPY-SC4FA
PSAS CP600i LP for LTO
requires 1x LP PCIe 4.0 x8 / for LTO drives1x
PYBSC4MA3LPY-SC4MA1
PSAS CP 2200-16i LP for LTO
requires 1x LP PCIe 4.0 x8 / for LTO drives available from 2024/031x
LTO drives (Need to select one of LTO drives togheter with SAS HBA)
LTO drives are not including tape drives. Cleaning Cartridge and Cables are included
LTO 7 tape drive (w/o tape)
6.0TB, 300MB/s, SAS 2.0, 5.25 inch/HalfHeight
LTO 8 tape drive (w/o tape)
12.0TB, 300MB/s, SAS 2.0, 5.25 inch/HalfHeight
LTO 9 tape drive (w/o tape)
18.0TB, 300MB/s, SAS 3.0, 5.25 inch/HalfHeight
1x
1x
1x
S26361-F5606-E1
S26361-F5789-E1
PYBLT911
S26361-F5606-L1
S26361-F5789-L1
PY-LT911
RDX drives
RDX drive is not including Cartridge.
RDX Drive cage (w/o cartriges)
USB 3.0, 5.25 inch / Half Height
RDX
RDX Cartrridge
RDX Cartridge 500GB
RDX Cartridge 1TB
RDX Cartridge 2TB
RDX Cartridge 4TB
1x
S26361-F3750-E4S26361-F3750-L4
-
-
-
-
-
-
-
-
S26361-F3857-L500
S26361-F3857-L600
S26361-F3857-L700
S26361-F3857-L900
K
cnfgTX2550M7-20231117_ckupPage 21 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
Chapter 10 - storage drives
SAS drives and SATA drives can be mixed, but cannot be used in one logical RAID volume.
SATA drives can be connected to the onboard Controller (max. 8x),
SAS drives require a dedicated SAS / RAID Controller
PCIe-SSDs can be connected to the onboard Controller, or require a dedicated RAID Controller or PCIe retimer/switch card.
Hard Disk Sector Format Information:
512n HDD: 512 byte sectors on the drive media.
512e (e=emulation) HDD: 4K physical sectors on the drive media with 512 byte logical configuration.
512e HDD Disk Drives: VMware 6.0 or earlier is not supported.
When using SSDs with VMware ESXi, select the SSDs that meet the endurance requirement describedin
KB2145210 below.
/kb/2145210
DWPD: Drive Writes Per Day over 5 years.
SED/FIPS are Self Encrypting Drives, and they require either a RAID controller with ®SafeStore (SED) support or an HBA and
in addition a software instance, supporting SED Key Management.
It is strongly recommended to order SafeStore (SED) RAID controller with SEDHDD or SSD devices for SafeStore (SED) functionality.
Non-SED drives and SED/FIPS drives can be mixed, but cannot be used in one logical RAID volume.
HDD Classes:
Business-Critical (BC) -SATA=Nearline SATA Enterprise Drives / 7.2Krpm,SATA 6G.
Business-Critical (BC) -SAS=Nearline SAS Enterprise Drives / 7.2Krpm,SAS 12G.
Mission-Critical (MC)=SAS 10K and SAS 15K Enterprise Drives with max. performance and reliability.
Warranty:
SSD and SATA DOM have a built-in Wear-Out indicator. In this case the warranty for such a component, as an
exception to the system warranty, is restricted to the time period until the indicator reaches the exhaust level.
K
2.5" (SFF) SAS and SATA SSD
SSD SAS 2.5" Write Intensive
(SFF) Enterprise with hot plug/hot replace tray
based on Kioxia PM7 drives
CapacityFormfactor
InterfaceEnduranceDWPDorder code E-partorder code L-part
800GB2.5" (SFF)
SAS 24Gb/sWrite Intensive10
PYBSS80NGFPY-SS80NGF
1.6TB2.5" (SFF)
SAS 24Gb/sWrite Intensive10
PYBSS16NGFPY-SS16NGF
800GB2.5" (SFF)
SAS 24Gb/sWrite Intensive10
SED FIPS available in CY24Q1
PYBSS80NGGPY-SS80NGG
1.6TB2.5" (SFF)
SAS 24Gb/sWrite Intensive10
SED FIPS available in CY24Q1
PYBSS16NGGPY-SS16NGG
max. 8x, 16x, 24x or 32x - depending on base unit & configuration
SSD SAS 2.5" Write Intensive
(SFF) Enterprise with hot plug/hot replace tray
based on Seagate Nytro3732/3750 drives
CapacityFormfactor
InterfaceEnduranceDWPDorder code E-partorder code L-part
400GB 2.5" (SFF)
SAS 12Gb/sWrite Intensive10
PYBSS40NGAPY-SS40NGA
800GB2.5" (SFF)
SAS 12Gb/sWrite Intensive10
PYBSS80NGAPY-SS80NGA
1.6TB2.5" (SFF)
SAS 12Gb/sWrite Intensive10
PYBSS16NGAPY-SS16NGA
400GB 2.5" (SFF)
SAS 12Gb/sWrite Intensive10 SED
PYBSS40NGWPY-SS40NGW
800GB2.5" (SFF)
SAS 12Gb/sWrite Intensive10 SED
PYBSS80NGWPY-SS80NGW
1.6TB2.5" (SFF)
SAS 12Gb/sWrite Intensive10 SED
PYBSS16NGWPY-SS16NGW
max. 8x, 16x, 24x or 32x - depending on base unit & configuration
SSD SAS 2.5" Mixed Use
(SFF) Enterprise with hot plug/hot replace tray
based on Kioxia PM7 drives
CapacityFormfactor
InterfaceEnduranceDWPDorder code E-partorder code L-part
1.6TB2.5" (SFF)
SAS 24Gb/sMixed Use3
PYBSS16NPMPY-SS16NPM
3.2TB2.5" (SFF)
SAS 24Gb/sMixed Use3
PYBSS32NPMPY-SS32NPM
6.4TB2.5" (SFF)
SAS 24Gb/sMixed Use3
PYBSS64NPMPY-SS64NPM
max. 8x, 16x, 24x or 32x - depending on base unit & configuration
SSD SAS 2.5" Mixed Use
(SFF) Enterprise with hot plug/hot replace tray
based on Seagate Nytro3532/3550 drives
CapacityFormfactor
InterfaceEnduranceDWPDorder code E-partorder code L-part
800GB2.5" (SFF)
SAS 12Gb/sMixed Use3
PYBSS80NPFPY-SS80NPF
1.6TB2.5" (SFF)
SAS 12Gb/sMixed Use3
PYBSS16NPFPY-SS16NPF
3.2TB2.5" (SFF)
SAS 12Gb/sMixed Use3
PYBSS32NPFPY-SS32NPF
6.4TB2.5" (SFF)
SAS 12Gb/sMixed Use3
PYBSS64NPFPY-SS64NPF
max. 8x, 16x, 24x or 32x - depending on base unit & configuration
cnfgTX2550M7-20231117__SSDPage 22 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
SSD SAS 2.5" Read Intensive
(SFF) Enterprise with hot plug/hot replace tray
based on Kioxia PM7 drives
CapacityFormfactor
InterfaceEnduranceDWPDorder code E-partorder code L-part
1.92TB 2.5" (SFF)
SAS 24Gb/sRead Intensive1
PYBSS19NNMPY-SS19NNM
3.84TB 2.5" (SFF)
SAS 24Gb/sRead Intensive1
PYBSS38NNLPY-SS38NNL
7.68TB 2.5" (SFF)
SAS 24Gb/sRead Intensive1
PYBSS76NNMPY-SS76NNM
15.36TB 2.5" (SFF)
SAS 24Gb/sRead Intensive1
PYBSS15NNLPY-SS15NNL
7.68TB 2.5" (SFF)
SAS 24Gb/sRead Intensive1
SED FIPS available in CY24Q1
PYBSS76NNNPY-SS76NNN
15.36TB 2.5" (SFF)
SAS 24Gb/sRead Intensive1
SED FIPS available in CY24Q1
PYBSS15NNMPY-SS15NNM
max. 8x, 16x, 24x or 32x - depending on base unit & configuration
will be available in CQ4'23
SSD SAS 2.5" Read Intensive
(SFF) Enterprise with hot plug/hot replace tray
based on Samsung PM1653 drives
CapacityFormfactor
InterfaceEnduranceDWPDorder code E-partorder code L-part
960GB 2.5" (SFF)
SAS 24Gb/sRead Intensive1 SED
PYBSS96NNMPY-SS96NNM
1.92TB 2.5" (SFF)
SAS 24Gb/sRead Intensive1 SED
PYBSS19NNPPY-SS19NNP
3.84TB 2.5" (SFF)
SAS 24Gb/sRead Intensive1 SED
PYBSS38NNNPY-SS38NNN
7.68TB 2.5" (SFF)
SAS 24Gb/sRead Intensive1 SED
PYBSS76NNPPY-SS76NNP
15.36TB 2.5" (SFF)
SAS 24Gb/sRead Intensive1 SED
PYBSS15NNNPY-SS15NNN
This SSDs can be used as Non-SED drives, but it requires a RAID controller with SED support for using as SED drives.
max. 8x, 16x, 24x or 32x - depending on base unit & configuration
SSD SAS 2.5" Read Intensive
(SFF) Enterprise with hot plug/hot replace tray
based on Seagate Nytro3332/3350 drives
CapacityFormfactor
InterfaceEnduranceDWPDorder code E-partorder code L-part
960GB 2.5" (SFF)
SAS 12Gb/sRead Intensive1
PYBSS96NNJPY-SS96NNJ
1.92TB 2.5" (SFF)
SAS 12Gb/sRead Intensive1
PYBSS19NNHPY-SS19NNH
3.84TB 2.5" (SFF)
SAS 12Gb/sRead Intensive1
PYBSS38NNHPY-SS38NNH
7.68TB 2.5" (SFF)
SAS 12Gb/sRead Intensive1
PYBSS76NNHPY-SS76NNH
15.36TB 2.5" (SFF)
SAS 12Gb/sRead Intensive1
PYBSS15NNGPY-SS15NNG
max. 8x, 16x, 24x or 32x - depending on base unit & configuration
will be available in CQ1'24
SSD SATA 2.5" Mixed Use (SFF)
Enterprise with hot plug/hot replace tray
based on Samsung PM897a drives
CapacityFormfactor
InterfaceEnduranceDWPDorder code E-partorder code L-part
480GB2.5" (SFF)
SATA 6Gb/sMixed Use3 SED
PYBSS48NKSPY-SS48NKS
960GB2.5" (SFF)
SATA 6Gb/sMixed Use3 SED
PYBSS96NKSPY-SS96NKS
1.92TB2.5" (SFF)
SATA 6Gb/sMixed Use3 SED
PYBSS19NKSPY-SS19NKS
3.84TB2.5" (SFF)
SATA 6Gb/sMixed Use3 SED
PYBSS38NKSPY-SS38NKS
This SSDs can be used as Non-SED drives, but it requires a RAID controller with SED support for using as SED drives.
max. 8x, 16x, 24x or 32x - depending on base unit & configuration
SSD SATA 2.5" Mixed Use (SFF)
Enterprise with hot plug/hot replace tray
based on Samsung PM897 drives
CapacityFormfactor
InterfaceEnduranceDWPDorder code E-partorder code L-part
480GB2.5" (SFF)
SATA 6Gb/sMixed Use3
PYBSS48NKQPY-SS48NKQ
960GB2.5" (SFF)
SATA 6Gb/sMixed Use3
PYBSS96NKQPY-SS96NKQ
1.92TB2.5" (SFF)
SATA 6Gb/sMixed Use3
PYBSS19NKQPY-SS19NKQ
3.84TB2.5" (SFF)
SATA 6Gb/sMixed Use3
PYBSS38NKQPY-SS38NKQ
max. 8x, 16x, 24x or 32x - depending on base unit & configuration
SSD SATA 2.5" Mixed Use (SFF)
Enterprise with hot plug/hot replace tray
based on Micron 5300/5400 MAX drives
CapacityFormfactor
InterfaceEnduranceDWPDorder code E-partorder code L-part
480GB2.5" (SFF)
SATA 6Gb/sMixed Use5,0
S26361-F5776-E480S26361-F5776-L480
960GB2.5" (SFF)
SATA 6Gb/sMixed Use5,0
S26361-F5776-E960S26361-F5776-L960
1.92TB2.5" (SFF)
SATA 6Gb/sMixed Use5,0
S26361-F5776-E192S26361-F5776-L192
3.84TB2.5" (SFF)
SATA 6Gb/sMixed Use3,5
S26361-F5776-E384S26361-F5776-L384
max. 8x, 16x, 24x or 32x - depending on base unit & configuration
will be available in CQ1'24
cnfgTX2550M7-20231117__SSDPage 23 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
SSD SATA 2.5" Read Intensive (SFF)
Enterprise with hot plug/hot replace tray
based on Samsung PM893a drives
CapacityFormfactor
InterfaceEnduranceDWPDorder code E-partorder code L-part
480GB2.5" (SFF)
SATA 6Gb/sRead Intensive1,0 SED
PYBSS48NMEPY-SS48NME
960GB2.5" (SFF)
SATA 6Gb/sRead Intensive1,0 SED
PYBSS96NMEPY-SS96NME
1.92TB2.5" (SFF)
SATA 6Gb/sRead Intensive1,0 SED
PYBSS19NMEPY-SS19NME
3.84TB2.5" (SFF)
SATA 6Gb/sRead Intensive1,0 SED
PYBSS38NMEPY-SS38NME
7.68TB2.5" (SFF)
SATA 6Gb/sRead Intensive1,0 SED
PYBSS76NMEPY-SS76NME
This SSDs can be used as Non-SED drives, but it requires a RAID controller with SED support for using as SED drives.
max. 8x, 16x, 24x or 32x - depending on base unit & configuration
SSD SATA 2.5" Read Intensive (SFF)
Enterprise with hot plug/hot replace tray
based on Samsung PM893 drives
CapacityFormfactor
InterfaceEnduranceDWPDorder code E-partorder code L-part
240GB2.5" (SFF)
SATA 6Gb/sRead Intensive1,0
PYBSS24NMDPY-SS24NMD
480GB2.5" (SFF)
SATA 6Gb/sRead Intensive1,0
PYBSS48NMDPY-SS48NMD
960GB2.5" (SFF)
SATA 6Gb/sRead Intensive1,0
PYBSS96NMDPY-SS96NMD
1.92TB2.5" (SFF)
SATA 6Gb/sRead Intensive1,0
PYBSS19NMDPY-SS19NMD
3.84TB2.5" (SFF)
SATA 6Gb/sRead Intensive1,0
PYBSS38NMDPY-SS38NMD
7.68TB2.5" (SFF)
SATA 6Gb/sRead Intensive1,0
PYBSS76NMDPY-SS76NMD
max. 8x, 16x, 24x or 32x - depending on base unit & configuration
SSD SATA 2.5" Read Intensive (SFF)
Enterprise with hot plug/hot replace tray
based on Micron 5300/5400PRO drives
CapacityFormfactor
InterfaceEnduranceDWPDorder code E-partorder code L-part
240GB2.5" (SFF)
SATA 6Gb/sRead Intensive1,5
S26361-F5783-E240S26361-F5783-L240
480GB2.5" (SFF)
SATA 6Gb/sRead Intensive1,5
S26361-F5783-E480S26361-F5783-L480
960GB2.5" (SFF)
SATA 6Gb/sRead Intensive1,5
S26361-F5783-E960S26361-F5783-L960
1.92TB2.5" (SFF)
SATA 6Gb/sRead Intensive1,5
S26361-F5783-E192S26361-F5783-L192
3.84TB2.5" (SFF)
SATA 6Gb/sRead Intensive1,2
S26361-F5783-E384S26361-F5783-L384
7.68TB2.5" (SFF)
SATA 6Gb/sRead Intensive0,6
S26361-F5783-E768S26361-F5783-L768
max. 8x, 16x, 24x or 32x - depending on base unit & configuration
L1
2.5" (SFF) Hard drives
EOL, as long as stock available
HDD SAS 2.5"
15K
(SFF) Enterprise Mission Critical with hot plug/hot replace tray
CapacityRPM
InterfaceSectororder code E-partorder code L-part
300GB
15 000SAS 12Gb/s512n
S26361-F5727-E530S26361-F5727-L530
600GB
15 000SAS 12Gb/s512n
S26361-F5727-E560S26361-F5727-L560
900GB
15 000SAS 12Gb/s512n
S26361-F5531-E590S26361-F5531-L590
max. 8x, 16x, 24x or 32x - depending on base unit & configuration
HDD SAS 2.5" 10K 512n
(SFF) Enterprise Mission Critical with hot plug/hot replace tray
CapacityRPM
InterfaceSectororder code E-partorder code L-part
300GB
10 000SAS 12Gb/s512n
S26361-F5729-E130S26361-F5729-L130
600GB
10 000SAS 12Gb/s512n
S26361-F5729-E160S26361-F5729-L160
1.2TB
10 000SAS 12Gb/s512n
S26361-F5729-E112S26361-F5729-L112
300GB
10 000SAS 12Gb/s512n SED
PYBSH301EUPY-SH301EU
600GB
10 000SAS 12Gb/s512n SED
PYBSH601EUPY-SH601EU
1.2TB
10 000SAS 12Gb/s512n SED
PYBSH121EUPY-SH121EU
max. 8x, 16x, 24x or 32x - depending on base unit & configuration
HDD SAS 2.5" 10K 512e
(SFF) Enterprise Mission Critical with hot plug/hot replace tray
CapacityRPM
InterfaceSectororder code E-partorder code L-part
1.8TB
10 000SAS 12Gb/s512e
S26361-F5730-E118S26361-F5730-L118
2.4TB
10 000SAS 12Gb/s512e
S26361-F5543-E124S26361-F5543-L124
1.8TB
10 000SAS 12Gb/s512e SED
PYBSH181DUPY-SH181DU
2.4TB
10 000SAS 12Gb/s512e SED
S26361-F5582-E124S26361-F5582-L124
max. 8x, 16x, 24x or 32x - depending on base unit & configuration
EOL, as long as stock available
HDD SAS 2.5" 7.2K 512n
(SFF) Enterprise Business Critical with hot plug/hot replace tray
CapacityRPM
InterfaceSectororder code E-partorder code L-part
1TB
7 200SAS 12Gb/s512n
S26361-F5600-E100S26361-F5600-L100
2TB
7 200SAS 12Gb/s512n
S26361-F5600-E200S26361-F5600-L200
max. 8x, 16x, 24x or 32x - depending on base unit & configuration
EOL, as long as stock available
HDD SATA 2.5" 7.2K 512n
(SFF) Enterprise Business Critical with hot plug/hot replace tray
CapacityRPM
InterfaceSectororder code E-partorder code L-part
1TB
7 200SATA 6Gb/s512n
S26361-F3956-E100S26361-F3956-L100
2TB
7 200SATA 6Gb/s512n
S26361-F3956-E200S26361-F3956-L200
max. 8x, 16x, 24x or 32x - depending on base unit & configuration
L2
cnfgTX2550M7-20231117__SSDPage 24 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
L2
3.5" (LFF) SATA SSD
will be available in CQ1'24
SSD SATA 3.5" Mixed Use
(LFF) 2.5" SSD Enterprise with 3.5" hot plug/hot replace tray
based on Samsung PM897a drives
CapacityFormfactor
InterfaceEnduranceDWPDorder code E-partorder code L-part
480GB3.5" (LFF)
SATA 6Gb/sMixed Use3 SED
PYBTS48NK9PY-TS48NK9
960GB3.5" (LFF)
SATA 6Gb/sMixed Use3 SED
PYBTS96NK9PY-TS96NK9
1.92TB3.5" (LFF)
SATA 6Gb/sMixed Use3 SED
PYBTS19NK9PY-TS19NK9
3.84TB3.5" (LFF)
SATA 6Gb/sMixed Use3 SED
PYBTS38NK9PY-TS38NK9
This SSDs can be used as Non-SED drives, but it requires a RAID controller with SED support for using as SED drives.
max. 4x, 8x, or 12x - depending on base unit & configuration
SSD SATA 3.5" Mixed Use
(LFF) 2.5" SSD Enterprise with 3.5" hot plug/hot replace tray
based on Samsung PM897 drives
CapacityFormfactor
InterfaceEnduranceDWPDorder code E-partorder code L-part
480GB3.5" (LFF)
SATA 6Gb/sMixed Use3
PYBTS48NK8PY-TS48NK8
960GB3.5" (LFF)
SATA 6Gb/sMixed Use3
PYBTS96NK8PY-TS96NK8
1.92TB3.5" (LFF)
SATA 6Gb/sMixed Use3
PYBTS19NK8PY-TS19NK8
3.84TB3.5" (LFF)
SATA 6Gb/sMixed Use3
PYBTS38NK8PY-TS38NK8
max. 4x, 8x, or 12x - depending on base unit & configuration
SSD SATA 3.5" Mixed Use (LFF)
2.5" SSD Enterprise with 3.5" hot plug/hot replace tray
based on Micron 5300/5400 MAX drives
CapacityFormfactor
InterfaceEnduranceDWPDorder code E-partorder code L-part
480GB2.5" (SFF)
SATA 6Gb/sMixed Use5,0
S26361-F5775-E480S26361-F5775-L480
960GB2.5" (SFF)
SATA 6Gb/sMixed Use5,0
S26361-F5775-E960S26361-F5775-L960
1.92TB2.5" (SFF)
SATA 6Gb/sMixed Use5,0
S26361-F5775-E192S26361-F5775-L192
3.84TB2.5" (SFF)
SATA 6Gb/sMixed Use3,5
S26361-F5775-E384S26361-F5775-L384
max. 4x, 8x, or 12x - depending on base unit & configuration
will be available in CQ1'24
SSD SATA 3.5" Read Intensive (LFF)
2.5" SSD Enterprise with 3.5" hot plug/hot replace tray
based on Samsung PM893a drives
CapacityFormfactor
InterfaceEnduranceDWPDorder code E-partorder code L-part
480GB3.5" (LFF)
SATA 6Gb/sRead Intensive1,0 SED
PYBTS48NMBPY-TS48NMB
960GB3.5" (LFF)
SATA 6Gb/sRead Intensive1,0 SED
PYBTS96NMAPY-TS96NMA
1.92TB3.5" (LFF)
SATA 6Gb/sRead Intensive1,0 SED
PYBTS19NMAPY-TS19NMA
3.84TB3.5" (LFF)
SATA 6Gb/sRead Intensive1,0 SED
PYBTS38NMAPY-TS38NMA
7.68TB3.5" (LFF)
SATA 6Gb/sRead Intensive1,0 SED
PYBTS76NMAPY-TS76NMA
This SSDs can be used as Non-SED drives, but it requires a RAID controller with SED support for using as SED drives.
max. 4x, 8x, or 12x - depending on base unit & configuration
SSD SATA 3.5" Read Intensive (LFF)
2.5" SSD Enterprise with 3.5" hot plug/hot replace tray
based on Samsung PM893 drives
CapacityFormfactor
InterfaceEnduranceDWPDorder code E-partorder code L-part
240GB3.5" (LFF)
SATA 6Gb/sRead Intensive1,0
PYBTS24NM9PY-TS24NM9
480GB3.5" (LFF)
SATA 6Gb/sRead Intensive1,0
PYBTS48NM9PY-TS48NM9
960GB3.5" (LFF)
SATA 6Gb/sRead Intensive1,0
PYBTS96NM9PY-TS96NM9
1.92TB3.5" (LFF)
SATA 6Gb/sRead Intensive1,0
PYBTS19NM9PY-TS19NM9
3.84TB3.5" (LFF)
SATA 6Gb/sRead Intensive1,0
PYBTS38NM9PY-TS38NM9
7.68TB3.5" (LFF)
SATA 6Gb/sRead Intensive1,0
PYBTS76NM9PY-TS76NM9
max. 4x, 8x, or 12x - depending on base unit & configuration
SSD SATA 3.5" Read Intensive (LFF)
2.5" SSD Enterprise with 3.5" hot plug/hot replace tray
based on Micron 5300/5400 PRO drives
CapacityFormfactor
InterfaceEnduranceDWPDorder code E-partorder code L-part
240GB2.5" (SFF)
SATA 6Gb/sRead Intensive1,5
S26361-F5782-E240S26361-F5782-L240
480GB2.5" (SFF)
SATA 6Gb/sRead Intensive1,5
S26361-F5782-E480S26361-F5782-L480
960GB2.5" (SFF)
SATA 6Gb/sRead Intensive1,5
S26361-F5782-E960S26361-F5782-L960
1.92TB2.5" (SFF)
SATA 6Gb/sRead Intensive1,5
S26361-F5782-E192S26361-F5782-L192
3.84TB2.5" (SFF)
SATA 6Gb/sRead Intensive1,2
S26361-F5782-E384S26361-F5782-L384
7.68TB2.5" (SFF)
SATA 6Gb/sRead Intensive0,6
S26361-F5782-E768S26361-F5782-L768
max. 4x, 8x, or 12x - depending on base unit & configuration
cnfgTX2550M7-20231117__SSDPage 25 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
3.5" (LFF) Hard drives
EOL, as long as stock available
HDD SAS 3.5"
15K
(LFF) 2.5" HDD Enterprise Mission Critical with 3.5" hot plug/hot replace tray
CapacityRPM
InterfaceSectororder code E-partorder code L-part
300GB
15 000SAS 12Gb/s512n
S26361-F5726-E530S26361-F5726-L530
600GB
15 000SAS 12Gb/s512n
S26361-F5726-E560S26361-F5726-L560
900GB
15 000SAS 12Gb/s512n
S26361-F5532-E590S26361-F5532-L590
max. 4x, 8x, or 12x - depending on base unit & configuration
HDD SAS 3.5"
10K 512n
(LFF) 2.5" HDD Enterprise Mission Critical with 3.5" hot plug/hot replace tray
CapacityRPM
InterfaceSectororder code E-partorder code L-part
300GB
10 000SAS 12Gb/s512n
S26361-F5728-E130S26361-F5728-L130
600GB
10 000SAS 12Gb/s512n
S26361-F5728-E160S26361-F5728-L160
1.2TB
10 000SAS 12Gb/s512n
S26361-F5728-E112S26361-F5728-L112
max. 4x, 8x, or 12x - depending on base unit & configuration
HDD SAS 3.5"
10K 512e
(LFF) 2.5" HDD Enterprise Mission Critical with 3.5" hot plug/hot replace tray
CapacityRPM
InterfaceSectororder code E-partorder code L-part
1.8TB
10 000SAS 12Gb/s512e
S26361-F5731-E118S26361-F5731-L118
2.4TB
10 000SAS 12Gb/s512e
S26361-F5569-E124S26361-F5569-L124
max. 4x, 8x, or 12x - depending on base unit & configuration
HDD SAS 3.5" 7.2K 512n
(LFF) Enterprise Business critical with hot plug/hot replace tray
CapacityRPM
InterfaceSectororder code E-partorder code L-part
2TB
7 200SAS 12Gb/s512n
PYBCH2T7G4PY-CH2T7G4
4TB
7 200SAS 12Gb/s512n
PYBCH4T7G4PY-CH4T7G4
max. 4x, 8x, or 12x - depending on base unit & configuration
HDD SAS 3.5" 7.2K 512e
(LFF) Enterprise Business Critical with hot plug/hot replace tray
CapacityRPM
InterfaceSectororder code E-partorder code L-part
6TB
7 200SAS 12Gb/s512e
PYBCH6T7B9PY-CH6T7B9
8TB
7 200SAS 12Gb/s512e
S26361-F5635-E800S26361-F5635-L800
12TB
7 200SAS 12Gb/s512e
PYBCHCT7B7PY-CHCT7B7
14TB
7 200SAS 12Gb/s512e
PYBCHET7B6PY-CHET7B6
16TB
7 200SAS 12Gb/s512e
S26361-F5571-E160S26361-F5571-L160
18TB
7 200SAS 12Gb/s512e
PYBCHJT7B2PY-CHJT7B2
20TB
7 200SAS 12Gb/s512eWiil be avairable in CQ1 2024
PYBCHLT7BPY-CHLT7B
6TB
7 200SAS 12Gb/s512e SED
PYBCH6T7BUPY-CH6T7BU
8TB
7 200SAS 12Gb/s512e SED
S26361-F5584-E800S26361-F5584-L800
12TB
7 200SAS 12Gb/s512e SED
PYBCHCT7BWPY-CHCT7BW
14TB
7 200SAS 12Gb/s512e SED
PYBCHET7BVPY-CHET7BV
16TB
7 200SAS 12Gb/s512e SED
S26361-F5624-E160S26361-F5624-L160
18TB
7 200SAS 12Gb/s512e SED
PYBCHJT7BTPY-CHJT7BT
20TB
7 200SAS 12Gb/s512e
FIPS Wiil be avairable in CQ1 2024
PYBCHLT7BSPY-CHLT7BS
max. 4x, 8x, or 12x - depending on base unit & configuration
HDD SATA 3.5" 7.2K 512n
(LFF) Enterprise Business Critical with hot plug/hot replace tray
CapacityRPM
InterfaceSectororder code E-partorder code L-part
1TB
7 200SATA 6Gb/s512n
PYBBH1T7B9PY-BH1T7B9
2TB
7 200SATA 6Gb/s512n
PYBBH2T7B9PY-BH2T7B9
4TB
7 200SATA 6Gb/s512n
PYBBH4T7B9PY-BH4T7B9
max. 4x, 8x, or 12x - depending on base unit & configuration
HDD SATA 3.5" 7.2K 512e
(LFF) Enterprise Business Critical with hot plug/hot replace tray
CapacityRPM
InterfaceSectororder code E-partorder code L-part
6TB
7 200SATA 6Gb/s512e
PYBBH6T7E9PY-BH6T7E9
8TB
7 200SATA 6Gb/s512e
S26361-F5638-E800S26361-F5638-L800
12TB
7 200SATA 6Gb/s512e
PYBBHCT7E4PY-BHCT7E4
14TB
7 200SATA 6Gb/s512e
PYBBHET7E4PY-BHET7E4
16TB
7 200SATA 6Gb/s512e
S26361-F3904-E160S26361-F3904-L160
18TB
7 200SATA 6Gb/s512e
PYBBHJT7E2PY-BHJT7E2
max. 4x, 8x, or 12x - depending on base unit & configuration
L3
cnfgTX2550M7-20231117__SSDPage 26 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
L3
M.2 SATA SSD
M.2 drive for VMware ESXi and for other OSs cannot be mixed
M.2 SATA and M.2 PCIe drive cannot be mixed
SSD SATA M.2 drive for booting, non hot-plug, for VMware ESXi
based on Micron 5300/5400 PRO drives
CapacityFormfactor
InterfaceCategoryorder code E-partorder code L-part
240GBM.2
SATA 6Gb/sBoot
S26361-F5816-E240S26361-F5816-L240
M.2 drive is designed for use as a VMware ESXi boot drive.
max. 1x per Server; in case M.2 drive is installed in connector located on Motherboard (please see folder "description"). VMware ESXi is only supported.
2x M.2 drives required; in case M.2 drives are used with PDUAL CP100 or CP300.
SSD SATA M.2 drive for booting, non hot-plug
based on Micron 5300/5400 PRO drives (960GB is 5400 only)
CapacityFormfactor
InterfaceDWPDCategoryorder code E-partorder code L-part
240GBM.2
SATA 6Gb/s1,5Boot
S26361-F5787-E240S26361-F5787-L240
480GBM.2
SATA 6Gb/s1,5Boot
S26361-F5787-E480S26361-F5787-L480
960GBM.2 2280
SATA 6Gb/s1,5Boot
PYBMF96YNPY-MF96YN
M.2 drive is designed for use as a boot drive with the Endurance Spec. above.
2x M.2 drive for any Hypervisor by the onboard chipset Software RAID is not supported.
max. 2x per Server; in case M.2 drive is installed in connector located on Motherboard (please see folder "description"). VMware is not supported.
2x M.2 drives required; in case M.2 drives are used with PDUAL CP100 or CP300.
SSD PCIe M.2 drive for booting, non hot-plug
based on Micron 7450 PRO drives
CapacityFormfactor
InterfaceDWPDCategoryorder code E-partorder code L-part
480GBM.2 2280
PCIe4.0 x40,9Boot
PYBBS48PEAPY-BS48PEA
960GBM.2 2280
PCIe4.0 x40,9Boot
PYBBS96PEAPY-BS96PEA
M.2 drive is designed for use as a boot drive with the Endurance Spec. above.
max. 2x per Server; connector located on Motherboard (please see folder "description"). 2x M.2 drives require Intel VROC Upgrade Key Premium(PYBRLVR02).
2x M.2 drives required; in case M.2 drives are used with PDUAL CP300.
Dual M.2
PDUAL CP100, PDUAL CP300 and M.2 drive on Motherboard cannot be mixed
PDUAL CP100, dual M.2 for booting, non hot-plug
CapacityFormfactor
InterfaceCategoryorder code E-partorder code L-part
n/aAIC
PCIeBootFH
PYBDMCP24
n/aAIC
PCIeBootLP
PYBDMCP24L
PY-DMCP24
PDUAL CP100 is a carrier of 2x SSD SATA M.2 drives, which offers RAID1 with the 2x SSD M.2 drives.
PDUAL CP100 is designed for use as a hardware-mirrored (RAID1) boot device for Hypervisor, which cannot be supported by M.2 via the onboard chipset Software RAID.
Supported RAID level : RAID1 only, 2x same type of SSD M.2 drives need to be ordered separately.
Supported M.2 drives : SSD SATA M.2 240GB/480GB/960GB or 240GB for VMware ESXi. (S26361-F5787- E240/L240/E480/L480, PY*MF96YN or S26361-F5816-E240/L240)
max. 1x per Server, requires 2x SSD SATA M.2 drives.
PDUAL CP100, PDUAL CP300 and M.2 drive on Motherboard cannot be mixed
PDUAL CP300, dual M.2 for booting, non hot-plug
available from 2024/02
CapacityFormfactor
InterfaceCategoryorder code E-partorder code L-part
n/aAIC
PCIeBootFH
PYBDMCP35
n/aAIC
PCIeBootLP
PYBDMCP35L
PY-DMCP35
PDUAL CP300 is a carrier of 2x SSD SATA or PCIe M.2 drives, which offers RAID1 with the 2x SSD M.2 drives.
PDUAL CP300 is designed for use as a hardware-mirrored (RAID1) boot device for Hypervisor, which cannot be supported by M.2 via the onboard chipset Software RAID.
Supported RAID levels : RAID1 and 0 (optional), 2x same type of SSD M.2 drives need to be ordered separately.
Supported M.2 drives : SSD SATA M.2 240GB/480GB/960GB or 240GB for VMware ESXi. (S26361-F5787- E240/L240/E480/L480, PY*MF96YN or S26361-F5816-E240/L240) or
SSD PCIe M.2 480GB/960GB. (PY*BS48PEA/PY*BS96PEA)
max. 1x per Server, requires 2x SSD M.2 drives.
cnfgTX2550M7-20231117__SSDPage 27 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
2.5" (SFF) PCIe-SSD
hot plug support : supported with VMD
PCIe-SSD 2.5" P5800X
(SFF) Enterprise with hot plug/hot replace tray
based on Intel P5800X drives
CapacityFormfactor
InterfaceEnduranceDWPDorder code E-partorder code L-part
400GB2.5" (SFF)
PCIe4.0 x4Write Intensive100
PYBBS40PFPY-BS40PF
800GB2.5" (SFF)
PCIe4.0 x4Write Intensive100
PYBBS80PFPY-BS80PF
1.6TB2.5" (SFF)
PCIe4.0 x4Write Intensive100
PYBBS16PFPY-BS16PF
max. 8x (4x per CPU) - depending on base unit & configuration
limitation : can not support VROC so farwill be available in CQ4'23
PCIe-SSD 2.5" Mixed Use
(SFF) Enterprise with hot plug/hot replace tray
based on Kioxia CM7-V drives
CapacityFormfactor
InterfaceEnduranceDWPDorder code E-partorder code L-part
1.6TB2.5" (SFF)
PCIe5.0 x4Mixed Use3
PYBBS16PDBPY-BS16PDB
3.2TB2.5" (SFF)
PCIe5.0 x4Mixed Use3
PYBBS32PDBPY-BS32PDB
6.4TB2.5" (SFF)
PCIe5.0 x4Mixed Use3
PYBBS64PDBPY-BS64PDB
12.8TB2.5" (SFF)
PCIe5.0 x4Mixed Use3
PYBBS12PDBPY-BS12PDB
max. 8x (4x per CPU) - depending on base unit & configuration
EOL, as long as stock available
PCIe-SSD 2.5" Mixed Use
(SFF) Enterprise with hot plug/hot replace tray
based on Kioxia CM6-V drives
CapacityFormfactor
InterfaceEnduranceDWPDorder code E-partorder code L-part
1.6TB2.5" (SFF)
PCIe4.0 x4Mixed Use3
PYBBS16PD6PY-BS16PD6
3.2TB2.5" (SFF)
PCIe4.0 x4Mixed Use3
PYBBS32PD6PY-BS32PD6
6.4TB2.5" (SFF)
PCIe4.0 x4Mixed Use3
PYBBS64PD6PY-BS64PD6
12.8TB2.5" (SFF)
PCIe4.0 x4Mixed Use3
PYBBS12PD6PY-BS12PD6
max. 8x (4x per CPU) - depending on base unit & configuration
limitation : can not support VROC so farwill be available in CQ4'23
PCIe-SSD 2.5" Read Intensive
(SFF) Enterprise with hot plug/hot replace tray
based on Kioxia CM7-R drives
CapacityFormfactor
InterfaceEnduranceDWPDorder code E-partorder code L-part
1.92TB2.5" (SFF)
PCIe5.0 x4Read Intensive1
PYBBS19PEAPY-BS19PEA
3.84TB2.5" (SFF)
PCIe5.0 x4Read Intensive1
PYBBS38PEAPY-BS38PEA
7.68TB2.5" (SFF)
PCIe5.0 x4Read Intensive1
PYBBS76PEAPY-BS76PEA
15.36TB2.5" (SFF)
PCIe5.0 x4Read Intensive1
PYBBS15PEBPY-BS15PEB
max. 8x (4x per CPU) - depending on base unit & configuration
EOL, as long as stock available
PCIe-SSD 2.5" Read Intensive
(SFF) Enterprise with hot plug/hot replace tray
based on Kioxia CM6-R drives
CapacityFormfactor
InterfaceEnduranceDWPDorder code E-partorder code L-part
960GB2.5" (SFF)
PCIe4.0 x4Read Intensive1
PYBBS96PE6PY-BS96PE6
1.92TB2.5" (SFF)
PCIe4.0 x4Read Intensive1
PYBBS19PE6PY-BS19PE6
3.84TB2.5" (SFF)
PCIe4.0 x4Read Intensive1
PYBBS38PE6PY-BS38PE6
7.68TB2.5" (SFF)
PCIe4.0 x4Read Intensive1
PYBBS76PE6PY-BS76PE6
15.36TB2.5" (SFF)
PCIe4.0 x4Read Intensive1
PYBBS15PE6PY-BS15PE6
max. 8x (4x per CPU) - depending on base unit & configuration
M
cnfgTX2550M7-20231117__SSDPage 28 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
M
Chapter 11 - LAN Components
FH PCI card requires FH PCI riser. Please refer to ''Chapter 14 - PCI Riser'.
Broadcom 1GbE BEASE-T for PCIe
PLAN CP BCM5719-4P 4X 1000BASE-T PCIe LP6x
PLAN CP BCM5719-4P 4X 1000BASE-T PCIe FH8x
Broadcom, 1GTx4port
PYBLA284L
PYBLA284
PY-LA284
max. 10 adapters per system
Intel 1GbE BASE-T for PCIe
PLAN CP 2x1Gbit Cu Intel I350-T2 LP *1
6x
Intel, 1GTx2port
S26361-F4610-E202S26361-F4610-L502
PLAN CP 4x1Gbit Cu Intel I350-T4 LP6x
Intel, 1GTx4port
S26361-F4610-E204
S26361-F4610-L504
max. 6 adapters per system
*1 Will be available from 2Q, CY2024
Broadcom 10GbE BEASE-T for PCIe
PLAN EP P210TP 2X 10GBASE-T PCIe LP4x
PLAN EP P210TP 2X 10GBASE-T PCIe FH6x
Broadcom, 10GTx2port
PYBLA3K2L
PYBLA3K2
PY-LA3K2
max. 6x adapters per system (must not exceed this number with P210TP and P210P in total and LP cannnot be put on slot#3, slot#10)
Intel 10GbE BASE-T for PCIe
PLAN EP X710-T2L 2X 10GBASE-T LP6xPYBLA342L
PLAN EP X710-T2L 2X 10GBASE-T FH8x
Intel, 10GTx2port
PYBLA342
PY-LA342
PLAN EP X710-T4L 4X 10GBASE-T LP6xPYBLA344L
PLAN EP X710-T4L 4X 10GBASE-T FH8x
Intel, 10GTx4port
PYBLA344
PY-LA344
max. 10x adapters per system
Broadcom 10GbE for PCIe
Each cage consumes 1x optical SFP+ transceiver per port.
Dual rate 10G/1G support requires 10G/1G Dual Rate SFP+ Optical Transceiver Modules.
All ports on this card can install the same Parts Number of optical module.
PLAN EP P210P 2x10Gb SFP PCIe LP4x
PYBLA3J2L
PLAN EP P210P 2x10Gb SFP PCIe FH6x
Broadcom, 10Gx2port
PYBLA3J2
PY-LA3J2
Optional, 10Gb SFP+ optical transceiver module, select one per cage
SFP+ Optical Transceiver 10G Single Rate SR
2x
Finisar, 10G SR SFP+
S26361-F3986-E3S26361-F3986-L3
SFP+ Optical Transceiver 10G/1G Dual Rate
SR
2x
Intel, 1G/10G SR SFP+
S26361-F3986-E5S26361-F3986-L5
SFP+ Optical Transceiver 10G/1G Dual Rate LR
2x
Intel, 1G/10G LR SFP+
S26361-F3986-E6S26361-F3986-L6
max. 1x per port
max. 6x adapters per system (must not exceed this number with P210TP and P210P in total and LP cannnot be put on slot#3, slot#10)
Intel 10GbE for PCIe
Each cage consumes 1x optical SFP+ transceiver per port.
Dual rate 10G/1G support requires 10G/1G Dual Rate SFP+ Optical Transceiver Modules.
All ports on this card can install the same Parts Number of optical module.
PLAN EP X710-DA2 2x10Gb SFP+ LP6xS26361-F3640-E202
PLAN EP X710-DA2 2x10Gb SFP+ FH8x
Intel, 10Gx2port
S26361-F3640-E2
S26361-F3640-L502
PLAN EP X710-DA4 4x10Gb SFP+ LP6xS26361-F3640-E204
PLAN EP X710-DA4 4x10Gb SFP+ FH8x
Intel, 10Gx4port
S26361-F3640-E4
S26361-F3640-L504
Optional, 10Gb SFP+ optical transceiver module, select one per cage
SFP+ Optical Transceiver 10G Single Rate SR
4x
Finisar, 10G SR SFP+
S26361-F3986-E3S26361-F3986-L3
SFP+ Optical Transceiver 10G/1G Dual Rate
SR
4x
Intel, 1G/10G SR SFP+
S26361-F3986-E5S26361-F3986-L5
SFP+ Optical Transceiver 10G/1G Dual Rate LR
4x
Intel, 1G/10G LR SFP+
S26361-F3986-E6S26361-F3986-L6
max. 1x per port
max. 10x adapters per system
Broadcom 25GbE for PCIe
Each cage consumes 1x optical SFP28.
All ports on this card can install the same Parts Number of optical module.
10G SFP BTO is not available for 25G cards, please select L parts.
PLAN EP P225P 25Gb 2p SFP28 PCIe LP *1
6x
PYBLA3H2L
PLAN EP P225P 25Gb 2p SFP28 PCIe FH *1
8x
Broadcom, 25Gx2port
PYBLA3H2
PY-LA3H2
Optional, 25Gb SFP28 optical transceiver module, select one per cage
SFP28 25G SR E25GSFP28SRX LC
2x
Intel, 25G SR SFP28PYBSFPS56PY-SFPS56
max. 1x per port
Optional, 10Gb SFP+ optical transceiver module, select one per cage
SFP+ Optical Transceiver 10G/1G Dual Rate
SR
2x
Intel, 1G/10G SR SFP+
S26361-F3986-E5S26361-F3986-L5
SFP+ Optical Transceiver 10G/1G Dual Rate LR
2x
Intel, 1G/10G LR SFP+
S26361-F3986-E6S26361-F3986-L6
max. 1x per port
max. 10x adapters per system
*1 Will be available from 1Q, CY2024
cnfgTX2550M7-20231117_NPage 29 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
NVIDIA 25GbE for PCIe
Each cage consumes 1x optical SFP28.
All ports on this card can install the same Parts Number of optical module.
10G SFP BTO is not available for 25G cards, please select L parts.
Ethernet Network Adapters
PLAN EP MCX6-LX 25Gb 2p SFP28 PCIe LP *1
6x
PYBLA402L4
PLAN EP MCX6-LX 25Gb 2p SFP28 PCIe FH *1
8x
NVIDIA, 25Gx2port
PYBLA4024
PY-LA4024
Optional, 25Gb SFP28 optical transceiver module, select one per cage
SFP28 25G SR E25GSFP28SRX LC
2x
Intel, 25G SR SFP28PYBSFPS56PY-SFPS56
SFP28 Optical Transceiver 25G SR MMA2P00-
AS LC
2x
NVIDIA, 25G SR SFP28S26361-F4054-E701S26361-F4054-L701
max. 1x per port
Optional, 10Gb SFP+ optical transceiver module, select one per cage
SFP+ Optical Transceiver 10G/1G Dual Rate
SR
2x
Intel, 1G/10G SR SFP+
S26361-F3986-E5S26361-F3986-L5
SFP+ Optical Transceiver 10G/1G Dual Rate LR
2x
Intel, 1G/10G LR SFP+
S26361-F3986-E6S26361-F3986-L6
max. 1x per port
max. 10x adapters per system
*1 Will be available from 1Q, CY2024
Intel 25GbE for PCIe
Each cage consumes 1x optical SFP28.
All ports on this card can install the same Parts Number of optical module.
10G SFP BTO is not available for 25G cards, please select L parts.
PLAN EP E810-XXVDA2 2X 25G SFP28 LP6x
PLAN EP E810-XXVDA2 2X 25G SFP28 FH8x
Intel, 25Gx2port
PYBLA402L
PYBLA402
PY-LA402
PLAN EP E810-XXVDA4 4X 25G SFP28 LP
6x
Intel, 25Gx4port
PYBLA404L
PY-LA404
Optional, 25Gb SFP28 optical transceiver module, select one per cage
SFP28 25G SR E25GSFP28SRX LC
4x
Intel, 25G SR SFP28
PYBSFPS56PY-SFPS56
max. 1x per port
Optional, 10Gb SFP+ optical transceiver module, select one per cage
SFP+ Optical Transceiver 10G/1G Dual Rate
SR
4x
Intel, 1G/10G SR SFP+
S26361-F3986-E5S26361-F3986-L5
SFP+ Optical Transceiver 10G/1G Dual Rate LR
4x
Intel, 1G/10G LR SFP+
S26361-F3986-E6S26361-F3986-L6
max. 1x per port
max. 10x adapters per system(E810-XXVDA2) / max. 6x adapters per system(E810-XXVDA4)
Broadcom 100GbE for PCIe
Each cage consumes 1x optical QSFP28
All ports on this card can install the same Parts Number of optical module.
PLAN EP P2100G 100Gb 2p QSFP56 PCIe LP *16xBroadcom, 100Gx2portPYBLA442LPY-LA442
PLAN EP P2100G 100Gb 2p QSFP56 PCIe FH *14xBroadcom, 100Gx2portPYBLA442PY-LA442
Optional, 100Gb QSFP28 Optical Transceiver module
QSFP28 100G SR4 E100GQSFP28SRX MPO
2x
Intel, 100G SR4 QSFP28PYBSFPS54PY-SFPS54
QSFP28 100G SR4 MPO 850nm 100m
MMA1B00-C100D
2x
NVIDIA, 100G SR4 QSFP28S26361-F4052-E701S26361-F4052-L701
max. 1x per port
max. 6x adapters per system
*1 Will be available from 1Q, CY2024
Intel 100GbE for PCIe
Each cage consumes 1x optical QSFP28.
The QSFP will not ship on the card because it will interfere with the shipping box.
All ports on this card can install the same Parts Number of optical module.
PLAN EP E810-CQDA2 2X 100G QSFP28 LP6x
Intel, 100Gx2portPYBLA432LPY-LA432
Optional, 100Gb QSFP28 Optical Transceiver module
QSFP28 100G SR4 E100GQSFP28SRX MPO
2x
Intel, 100G SR4 QSFP28PYBSFPS54PY-SFPS54
max. 1x per port
max. 6x adapters per system
NVIDIA 100GbE for PCIe
Each cage consumes 1x optical QSFP28
The QSFP will not ship on the card because it will interfere with the shipping box.
All ports on this card can install the same Parts Number of optical module.
PLAN EP MCX6-DX 2X 100G QSFP28 LP6x
NVIDIA, 100Gx2portPYBLA412LPY-LA412
Optional, 100Gb QSFP28 Optical Transceiver module
QSFP28 100G SR4 MPO 850nm 100m
MMA1B00-C100D
2x
NVIDIA, 100G SR4 QSFP28
S26361-F4052-E701S26361-F4052-L701
max. 1x per port
max. 6x adapters per system
N
Network cables for later upgrade
O
cnfgTX2550M7-20231117_NPage 30 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
Chapter 12 - Fibre Channel Controller
O
FH PCIe card requires FH PCIe riser card. Please refer to ''Chapter 14 - PCI riser card'.
max number of some controllers can vary with base units with 6x card slots
64G Fibre Channel adapters with LC interface for 50µm optical cables (OM4 or OM3)
PFC EP LPe36000 1X 32GFC PCIe v4 LP6x
Broadcom, 64GFCx1port
PFC EP LPe36000 1X 32GFC PCIe FH8x
PFC EP LPe36002 2X 32GFC PCIe v4 LP6x
Broadcom, 64GFCx2port
PFC EP LPe36002 2X 32GFC PCIe v4 FH8x
6x
PFC EP QLE2870 1X 32GFC PCIe v4 LP
Marvell, 64GFCx1port
PFC EP QLE2870 1X 32GFC PCIe v4 FH 8x
PFC EP QLE2872 2X 32GFC PCIe v4 LP 6x
Marvell, 64GFCx2port
PFC EP QLE2872 2X 32GFC PCIe v4 FH 8x
32G Fibre Channel adapters with LC interface for 50µm optical cables (OM4 or OM3)
PFC EP LPe35000 1X 32GFC PCIe v4 LP6x
Broadcom, 32GFCx1port
PFC EP LPe35000 1X 32GFC PCIe v4 FH8x
PFC EP LPe35002 2X 32GFC PCIe v4 LP6x
Broadcom, 32GFCx2port
PFC EP LPe35002 2X 32GFC PCIe v4 FH8x
PFC EP QLE2770 1X 32GFC PCIe v4 LP6x
Marvell, 32GFCx1port
PFC EP QLE2770 1X 32GFC PCIe v4 FH8x
PFC EP QLE2772 2X 32GFC PCIe v4 LP6x
Marvell, 32GFCx2port
PFC EP QLE2772 2X 32GFC PCIe v4 FH 8x
16G Fibre Channel adapters with LC interface for 50µm optical cables (OM4 or OM3)
PFC EP LPe31000 1x 16Gb LP6x
Broadcom, 16GFCx1port
PFC EP LPe31000 1x 16Gb FH8x
PFC EP LPe31002 2x 16Gb LP6x
Broadcom, 16GFCx2port
PFC EP LPe31002 2x 16Gb FH8x
PFC EP QLE2690 1x 16Gb LP6x
Marvell, 16GFCx1port
PFC EP QLE2690 1x 16Gb FH8x
PFC EP QLE2692 2x 16Gb LP6x
Marvell, 16GFCx2port
PFC EP QLE2692 2x 16Gb FH8x
max. 10 adapters per system
PYBFC441L
PYBFC441
PYBFC442L
PYBFC442
PYBFC431L
PYBFC431
PYBFC432L
PYBFC432
PYBFC421L
PYBFC421
PYBFC422L
PYBFC422
PYBFC411L
PYBFC411
PYBFC412L
PYBFC412
S26361-F5596-E201
S26361-F5596-E1
S26361-F5596-E202
S26361-F5596-E2
S26361-F5580-E201
S26361-F5580-E1
S26361-F5580-E202
S26361-F5580-E2
PY-FC441
PY-FC442
PY-FC431
PY-FC432
PY-FC421
PY-FC422
PY-FC411
PY-FC412
S26361-F5596-L501
S26361-F5596-L502
S26361-F5580-L501
S26361-F5580-L502
Chapter 13 - Infiniband Controllers
Infinibandand Omni path controller will not be released.
P
cnfgTX2550M7-20231117__IBPage 31 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
Chapter 14 - PCI riser card
PCI riser card configuration
Standard Model only(PYT2557TAN/PYT2557TBN/PYT2557TCN
/PYT2557R3N/PYT2557R2N/PYT2557RAN)
6x PCIe slots are on board, with optional PCIe riser card up to 10x PCIe slots are available.
You can choose between 6 different PCI riser card (Options a – f), depending on the selected PCIe card or GPGPU.
Please refer to the tables below for more details and for the installation rules.
Required 'Configuration Thermal Design 30°C(CTD30)[PYBETA1]'
P
Full height PCIe card
A100, A30, A16, L40
or x16 PCIe card
is selected
Details of each PCIe riser card option (a – f) are described on the following pages
T400 4GB, A2, L4,
RTX A6000, RTX
A4500, RTX 6000
or x16 PCIe card
is selected
T400 4GB
or x8 PCIe card
is selected
Option c)
Full height 4slot PCIe riser card
(x8 Gen4)
A100, A30, A16, L40,
,H100
or x16 PCIe card
is selected
T400 4GB, A2, L4,
RTX A6000, RTX
A4500, RTX 6000
or x16 PCIe card
is selected
T400 4GB
or x8 PCIe card
is selected
Option f)
Full height 4slot PCIe riser card
(x8 Gen5)
with retimer
Option a)
Full height 2slot PCIe riser card
(x16 Gen4)
with PCIe support bracket
Option d)
Full height 2slot PCIe riser card
(x16 Gen5)
with PCIe support bracket
with retimer
Option b)
Full height 2slot PCIe riser card
(x16 Gen4)
without PCIe support bracket
Option e)
Full height 2slot PCIe riser card
(x16 Gen5)
without PCIe support bracket
with retimer
Q
Possible configurations with each PCIe riser card option
*Support brackets are required for the cooling of passively cooled FH GPUs.
cnfgTX2550M7-20231117_I_riser_cardPage 32 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
Option a) Full height 2slot PCIe riser card (x16 Gen4) with PCIe support bracket
If the below 2 options are selected, 6x PCIe slots (LP/ x16) change to 2x PCIe slots (LP/ x16) + 4x PCIe slots (FH/ x16).
PCIe cards and double width GPGPUs can be supported on 4x PCIe slots (FH/ x16).
One full height GPGPU can be installed on 1x PCIe slot (FH/ x16).
Support brackets are required for the cooling of passively cooled FH GPUs.“
A100, A30, A16, L40 and / or FH PCIe card is selected
Full height 2slot PCIe riser card right (CPU 1) with PCIe support bracket
PYBPRE638 / PY-PRE638
x16 Gen4 PCIe riser card
Note:
With this card, 3x PCIe slots (LP/ x16) change to 1x PCIe slots (LP/ x16) + 2x PCIe slots (FH/ x16).
Please refer to ‘Chapter 5 – Graphics cards’ for more details about the supported GPGPUs’.
Please refer to chapter ‘Thermal’ for more details about limitations’.
Full height 2slot PCIe riser card left (CPU 2) with PCIe support bracket
PYBPRE639 / PY-PRE639
x16 Gen4 PCIe riser card
Note:
2nd CPU is needed.
With this card, 3x PCIe slots (LP/ x16) change to 1x PCIe slots (LP/ x16) + 2x PCIe slots (FH/ x16).
Please refer to ‘Chapter 5 – Graphics cards’ for more details about the supported GPGPUs'.
Option b) Full height 2slot PCIe riser cards (x16 Gen4) without PCIe support bracket
If the below 2 options are selected, 6x PCIe slots (LP/ x16) change to 2x PCIe slots (LP/ x16) + 4x PCIe slots (FH/ x16).
PCIe cards and double width GPGPUs can be supported on 4x PCIe slots (FH/ x16).
One full height GPGPU can be installed on 1x PCIe slot (FH/ x16).
T400 4GB, A2, L4, RTX A6000, RTX A4500, RTX 6000 and / or FH PCIe card is selected
Full height 2slot PCIe riser card right (CPU 1) without PCIe support bracket
PYBPRE641 / PY-PRE641
x16 Gen4 PCIe riser card
Note:
With this card, 3x PCIe slots (LP/ x16) change to 1x PCIe slots (LP/ x16) + 2x PCIe slots (FH/ x16).
Please refer to ‘Chapter 5 – Graphics cards’ for more details about the supported GPGPUs’.
Please refer to chapter ‘Thermal’ for more details about limitations’.
Full height 2slot PCIe riser card left (CPU 2) without PCIe support bracket
PYBPRE642 / PY-PRE642
x16 Gen4 PCI Riser
Note:
2nd CPU is needed.
With this card, 3x PCIe slots (LP/ x16) change to 1x PCIe slots (LP/ x16) + 2x PCIe slots (FH/ x16).
Please refer to ‘Chapter 5 – Graphics cards’ for more details about the supported GPGPUs'.
Option c) Full height 4slot PCIe riser card (x8 Gen4)
If the below 2 options are selected, 6x PCIe slots (LP/ x16) change to 2x PCIe slots (LP/ x16) + 8x PCIe slots (FH/ x8).
GPGPU(Double height) cannot be supported.
T400 4GB and / or FH PCIe card is selected
Full height 4slot PCIe riser card right (CPU1)
PYBPRE848 / PY-PRE848
x8 Gen4 PCIe riser card
Note:
With this card, 3x PCIe slots (LP/ x16) change to 1x PCIe slots (LP/ x16) + 4x PCIe slots (FH/ x8).
Please refer to ‘Chapter 5 – Graphics cards’ for more details about the supported GPGPUs’.
Please refer to chapter ‘Thermal’ for more details about limitations’.
Full height 4slot PCIe riser card left (CPU2)
PYBPRE849 /PY-PRE849
x8 Gen4 PCI Riser
Note:
2nd CPU is needed
With this card, 3x PCIe slots (LP/ x16) change to 1x PCIe slots (LP/ x16) + 4x PCIe slots (FH/ x8).
Please refer to ‘Chapter 5 – Graphics cards’ for more details about the supported GPGPUs’.
cnfgTX2550M7-20231117_I_riser_cardPage 33 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
Option d) Full height 2slot PCIe riser card (x16 Gen5) with PCIe support bracket with Retimer
If the below 2 options are selected, 6x PCIe slots (LP/ x16) change to 2x PCIe slots (LP/ x16) + 4x PCIe slots (FH/ x16).
PCIe cards and double width GPGPUs can be supported on 4x PCIe slots (FH/ x16).
One full height GPGPU can be installed on 1x PCIe slot (FH/ x16).
Support brackets are required for the cooling of passively cooled FH GPUs.“
A100, A30, A16, L40, H100 and / or FH PCIe card is selected
Full height 2slot PCIe riser card right (CPU 1) with PCIe support bracket with Retimer
PYBPRE643 / PY-PRE643
x16 Gen5 PCI riser card
Note:
With this card, 3x PCIe slots (LP/ x16) change to 1x PCIe slots (LP/ x16) + 2x PCIe slots (FH/ x16).
Please refer to ‘Chapter 5 – Graphics cards’ for more details about the supported GPGPUs’.
Please refer to chapter ‘Thermal’ for more details about limitations’.
Full height 2slot PCIe riser card left (CPU 2) with PCIe support bracket with Retimer
PYBPRE644 / PY-PRE644
x16 Gen5 PCI riser card
Note:
2nd CPU is needed.
With this card, 3x PCIe slots (LP/ x16) change to 1x PCIe slots (LP/ x16) + 2x PCIe slots (FH/ x16).
Please refer to ‘Chapter 5 – Graphics cards’ for more details about the supported GPGPUs'.
Option e) Full height 2slot PCIe riser card (x16 Gen5) without PCIe support bracket with Retimer
If the below 2 options are selected, 6x PCIe slots (LP/ x16) change to 2x PCIe slots (LP/ x16) + 4x PCIe slots (FH/ x16).
PCIe cards and double width GPGPUs can be supported on 4x PCIe slots (FH/ x16).
One full height GPGPU can be installed on 1x PCIe slot (FH/ x16).
T400 4GB, A2, L4, RTX A6000, RTX A4500, RTX 6000 and / or FH PCIe card is selected
Full height 2slot PCIe riser card right (CPU 1) without PCIe support bracket with Retimer
PYBPRE645 / PY-PRE645
x16 Gen5 PCI riser card
Note:
With this card, 3x PCIe slots (LP/ x16) change to 1x PCIe slots (LP/ x16) + 2x PCIe slots (FH/ x16).
Please refer to ‘Chapter 5 – Graphics cards’ for more details about the supported GPGPUs’.
Please refer to chapter ‘Thermal’ for more details about limitations’.
Full height 2slot PCIe riser card left (CPU 2) without PCIe support bracket with Retimer
PYBPRE646 / PY-PRE646
x16 Gen5 PCI riser card
Note:
2nd CPU is needed.
With this card, 3x PCIe slots (LP/ x16) change to 1x PCIe slots (LP/ x16) + 2x PCIe slots (FH/ x16).
Please refer to ‘Chapter 5 – Graphics cards’ for more details about the supported GPGPUs'.
Option f) Full height 4slot PCIe riser card (x8 Gen5) with Retimer
If the below 2 options are selected, 6x PCIe slots (LP/ x16) change to 2x PCIe slots (LP/ x16) + 8x PCIe slots (FH/ x8).
GPGPU(Double height) cannot be supported.
T400 4GB and / or FH PCIe card is selected
Full height 4slot PCIe riser card right (CPU1) with Retimer
PYBPRE851 / PY-PRE851
x8 Gen5 PCI riser card
Note:
With this card, 3x PCIe slots (LP/ x16) change to 1x PCIe slots (LP/ x16) + 4x PCIe slots (FH/ x8).
Please refer to ‘Chapter 5 – Graphics cards’ for more details about the supported GPGPUs’.
Please refer to chapter ‘Thermal’ for more details about limitations’.
Full height 4slot PCIe riser card left (CPU2) with Retimer
PYBPRE852 / PY-PRE852
x8 Gen5 PCI riser card
Note:
2nd CPU is needed
With this card, 3x PCIe slots (LP/ x16) change to 1x PCIe slots (LP/ x16) + 4x PCIe slots (FH/ x8).
Please refer to ‘Chapter 5 – Graphics cards’ for more details about the supported GPGPUs’.
cnfgTX2550M7-20231117_I_riser_cardPage 34 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
Chapter 15 - Power supply unit, power cable, certifications, region kits
R
Power supply unit
modular redundant Power Supply
2nd PSU for redundancy basically.
occupies hot plug PSU slot, min. 1 / max. 2x per system. The different PSU mixed configuration does NOT support.
input nominal voltage (AC): 100V-240V, max: 90V-264V; input dropout 10ms/100% load, 47Hz-63Hz
500W platinum PSU
94% eff. Connector type: C13, APAC/JAPAN region only
PYBPU501PY-PU501
500W titanium PSU
96% eff. Connector type: C13, nom. 220-240V, max. 180-264V
PYBPU503PY-PU503
900W platinum PSU
94% eff. Connector type: C13, APAC/JAPAN region only
PYBPU902PY-PU902
900W titanium PSU
96% eff. nom. 220-240V, max. 180-264V
PYBPU901PY-PU901
1600W platinum PSU
94% eff. Connector type: C13, APAC/JAPAN region only
PYBPU163PY-PU163
1600W titanium PSU
96% eff. Connector type: C13, nom. 220-240V, max. 180-264V
PYBPU165PY-PU165
2200W platinum PSU
94% eff. Connector type: C19 200~240V only, APAC/JAPAN region only
PYBPU221PY-PU221
2400W Titanium PSU
96% eff. Connector type: C19, nom. 220-240V, max. 180-264V
PYBPU243PY-PU243
Dummy module instead PSU
Dummy module for closing the 2nd PSU hole, in case only 1 PSU is equipped, max. 1x per systemPYBDMP06-
If Power consumption error occureson 2400W PSU, 'No Redundant' can be selected
PYBVS002
No Power redundant option
If this option is selected, the system may shutdown at the worst case
Note: 2x 1600W or 2x 2200W or 2x 2400W are mandatory.
in one PSU failure. Not allow activity exchange for PSU even if
If Power budget isn't enough even if 2400W PSU is used, it can be used.
two PSU are selected.
max. 1x per system
Power cord option for Tower Server, 1x per PSU
Cable powercord (USA) 15A, 1.8m, black, NEMA 5-15 connector 498G -> C13 (plug), 15A, , rack or wall
T26139-Y1741-E90T26139-Y1741-L90
Cable powercord (Taiwan), 1.8m, rack or wall
T26139-Y1757-E10T26139-Y1757-L10
Cable powercord (D, A, B, F, NL, FIN, N, S, E, P, RUS, TR), 1.8m, grey
T26139-Y1740-E10T26139-Y1740-L10
Cable powercord (China), 1.8m, grey
T26139-Y1743-E10-
Cable powercord (China), 1.8m, black
-T26139-Y1751-L10
Cable powercord (UK, IR), 1.8m, grey
T26139-Y1744-E10T26139-Y1744-L10
Cable powercord (I), 1.8m, grey
T26139-Y1745-E10T26139-Y1745-L10
Cable powercord (DK), 1.8m, grey
T26139-Y1746-E10T26139-Y1746-L10
Cable powercord (ISR), 2.5m, black
T26139-Y1747-E18T26139-Y1747-L18
2200w or more
Power cord 16A IEC320 C19->CEE 7/7, 2.5m for 2200W/2400W PSU
S26361-F3151-L100
Power cord 16A IEC320 C19->C20, 3.5m for 2200W/2400W PSU
S26361-F3151-E300S26361-F3151-L300
Power cord IEC320 C19 -> US NEMA L6-20p, 4m for 2200W/2400W PSU
S26361-F3151-E500S26361-F3151-L500
common
no power cord
T26139-Y3850-E10
Power cord option for Rack Server, 1x per PSU
Cable powercord rack, 1.8m, black, IEC 320 C14 -> C13 (10A plug)
T26139-Y1968-E180T26139-Y1968-L180
Cable powercord rack, 2.5m, black, IEC 320 C14 -> C13 (10A plug)
T26139-Y1968-E250T26139-Y1968-L250
Cable powercord rack, 4m, black, IEC 320 C14 -> C13 (10A plug)
T26139-Y1968-E100T26139-Y1968-L10
Cable powercord (USA) 15A, 1.8m, black, NEMA 5-15 connector 498G -> C13 (plug), 15A, , rack or wall
T26139-Y1741-E90T26139-Y1741-L90
Cable powercord (Taiwan), 1.8m, rack or wall
T26139-Y1757-E10T26139-Y1757-L10
Cable powercord (D, A, B, F, NL, FIN, N, S, E, P, RUS, TR), 1.8m, grey
T26139-Y1740-E10T26139-Y1740-L10
Cable powercord (China), 1.8m, grey
T26139-Y1743-E10-
Cable powercord (China), 1.8m, black
-T26139-Y1751-L10
Cable powercord (UK, IR), 1.8m, grey
T26139-Y1744-E10T26139-Y1744-L10
Cable powercord (I), 1.8m, grey
T26139-Y1745-E10T26139-Y1745-L10
Cable powercord (DK), 1.8m, grey
T26139-Y1746-E10T26139-Y1746-L10
Cable powercord (ISR), 2.5m, black
T26139-Y1747-E18T26139-Y1747-L18
2200w or more
Power cord 16A IEC320 C19->CEE 7/7, 2.5m for 2200W/2400W PSU
S26361-F3151-L100
Power cord 16A IEC320 C19->C20, 3.5m for 2200W/2400W PSU
S26361-F3151-E300S26361-F3151-L300
Power cord IEC320 C19 -> US NEMA L6-20p, 4m for 2200W/2400W PSU
S26361-F3151-E500S26361-F3151-L500
common
no power cord
T26139-Y3850-E10
One region kit mandatory
S26361-F1452-E100S26361-F1452-E101S26361-F1452-E130S26361-F1452-E140
REGION KIT APAC/EMEARegion Kit China for CCCREGION KIT AmericaREGION KIT Europe
For Shipments to Asia pacific, Contains warranty sheet and For Shipments to America
America, EMEA regionssafety instructions for China, regions
need to be included always into
the order from China country
1x per system1x per system1x per system1x per system
S26361-F3301-E120
Certification for China, (CCC)
Certification for China, (CCC), Reduced component
selection possible, only with no power cord option
1x per system
S
cnfgTX2550M7-20231117_UPage 35 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
Chapter 16 - Accessories
S
USB Mouse:
Mouse M520 Black
n/aS26381-K467-L100
Mouse M520 Greyn/a
S26381-K467-L101
Mouse M530 Blackn/aS26381-K468-L100
Mouse M530 Greyn/aS26381-K468-L101
USB Keyboards for Tower Servers for following countries:
Country versionFUJITSU Keyboard KB521 USB (grey)
US/ int 105 keys (UK keyboard + US int. Layout)S26381-K521-L102
Czech/SlovakS26381-K521-L104
US 104 keys (US keyboard + US layout)S26381-K521-L110
GermanyS26381-K521-L120
Germany / IntS26381-K521-L122
FranceS26381-K521-L140
Sweden / FinlandS26381-K521-L154
United KingdomS26381-K521-L165
SwitzerlandS26381-K521-L170
SpainS26381-K521-L180
ItalyS26381-K521-L185
USB Optical Disc Drive
External Ultra Slim Portable DVD Writer (Hitachi-LG)
S26341-F103-L142
T
cnfgTX2550M7-20231117_B devicesPage 36 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
Chapter 17 - Energy Star
T
will be expired after 2024-1-11will be expired after 2024-1-11will be effective after 2024-1-12will be effective after 2024-1-12
S26361-F3301-E551S26361-F3301-E552PYBES26PYBES27
TX2550 Mx E-Star Fam1TX2550 Mx E-Star Fam2TX2550 Mx E-Star Fam1TX2550 Mx E-Star Fam2
Limits configuration in accordance Limits configuration in accordance Limits configuration in accordance Limits configuration in accordance
with Energy Star requirements for systems with 1 CPUwith Energy Star requirements for systems with 2 CPUwith Energy Star requirements for systems with 1 CPUwith Energy Star requirements for systems with 2 CPU
max. 1x per systemmax. 1x per systemmax. 1x per systemmax. 1x per system
1 CPU Variant1 CPU Variant
notallowed are:
limitations for E-Star Fam1certification
2 CPU Variant
notallowed are:
limitations for E-Star Fam2certification
notallowed are:
limitations for E-Star Fam1certification
2 CPU Variant
notallowed are:
limitations for E-Star Fam2certification
-2 CPU configuration
-1 CPU configuration
-2 CPU configuration
-1 CPU configuration
-CPU Xeon Bronze 3408U
-CPU Xeon Bronze 3408U
-CPU Xeon Bronze 3408
-CPU Xeon Silver 4410Y
-CPU Xeon Silver 4410Y
-CPU Xeon Silver 4416+
-CPU Xeon Silver 4416+
-CPU Xeon Gold 5415+
-CPU Xeon Gold 5415+
-CPU Xeon Gold 6426Y
-CPU Xeon Gold 6426Y
-CPU Xeon Gold 6434
-CPU Xeon Gold 6434
-CPU Xeon platinum 8444H
-CPU Xeon platinum 8444H
-CPU Xeon Gold 5416S
-CPU Xeon Gold 5416S
-CPU Xeon Silver 4410T
-CPU Xeon Silver 4410T
-900W platinum PSU
-900W platinum PSU
-1600W platinum PSU
-1600W platinum PSU
-2200W platinum PSU
-2200W platinum PSU
ENERGY STAR-configurations with one CPU will be labeled:
PRIMERGY TX2550 M7 E-Star Fam1
ENERGY STAR-configurations with two CPU will be labeled:
PRIMERGY TX2550 M7 E-Star Fam2
non ENERGY STAR-configurationen will be labeled:
PRIMERGY TX2550 M7
U
cnfgTX2550M7-20231117_ergy StarPage 37 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
Chapter 18 - others (ErP Lot 9 restriction)
U
*Region kit Europe must be orderd for
shipment toship in EU and EFTA
Region Kits, 1x per System
Region Kit APAC/EMEA/India,
Contains warranty sheet and safety instructions
for APAC, EMEA and India
Region Kit America,
Contains warranty sheet, registration hints and
safety instructions for America
S26361-F1452-E100
Region Kits, 1x per System
Region Kit Europe*,
Contains warranty sheet and safety instructions
in German, English, French, Spanish, Italian,
Polish, Russian and Welsh language
S26361-F1452-E140
S26361-F1452-E130
Restriction for ErP Lot 9 directive,
Not allowed: (For all base unit)
- 500W platinum PSU
- 900W platinum PSU
- 1600W platinum PSU
- 2200W platinum PSU
need to select one of PYBETL17 or PYBETL18
ErP Lot9 Restriction for 16GB DIMM, 1x per System
For 2.5" base unit only
2.5" base unit: PYT2557T2N, PYT2557TBN, PYT2557TCN, PYT2557R2N,
PYT2557RAN
Erp Lot9 configuration 1
PYBETL17
ErP Lot9 Restriction for >=32GB DIMM, 1x per System
For all 3.5", 2.5" base unit
3.5" base unti: PYT2557T3N, PYT2557TAN, PYT2557R3N
2.5" base unit: PYT2557T2N, PYT2557TBN, PYT2557TCN, PYT2557R2N,
PYT2557RAN
ErP Lot 9 configuration 2
PYBETL18
Restriction for ErP Lot9 directive,
* this option is NOT avaialble for 3.5" base unit.
(For PYT2557T2N, PYT2557TBN, PYT2557TCN, PYT2557R2N,
PYT2557RAN)
Not allowed:
-CPU: Bronze 3408U (PYBCP65XR)
-NVIDIAT400 (PYBVG4T2L)
-NVMe SSD (PYBBA24PJ, PYBBA24PK, PYBCBE024,
PYBCBE025)
Max qty of 1G LAN card restricted to max. 2
1G LAN: S26361-F4610-E204, PYBLA284L, PYBLA284
Restriction for ErP Lot9 directive,
(For PYT2557T3N, PYT2557TAN, PYT2557R3N,
PYT2557T2N, PYT2557TBN, PYT2557TCN, PYT2557R2N,
PYT2557RAN)
Not allowed:
-CPU: Bronze 3408U (PYBCP65XR)
-DIMM: 16GB DIMM (PYBME16SL)
V
cnfgTX2550M7-20231117_P Lot9Page 38 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
Chapter 19 - others
V
PYBRMC44
PY-RMC44
iRMC advanced pack
integrated remote Management controller activation key for graphical
console redirection and remote media redirection
max. 1x per system
PYBLCM14
embedded Lifecycle Management (eLCM)Loose delivery
Server Online UpdateeLCM Activation Pack
OS driver Update(Node Locked License)
Hardware firmware updatePY-LCM14
Server Offline Updateoptions contains:
Hardware update via Update Manager Express- Paper with TAN for Licensekey
PrimeCollect
Autonomous creation of Primecollect archives
Custom Image (Jukebox function)
Automatic and manual download of CD and DVD Images
Automatic and manual start of CD and DVD Images
max. 1x per system
PYBSSS3
iRMC standard/legacy Option
When this product is orderd, following iRMC default setting is changed.
Unique default password: No. The fixed password is printed on ID tag.
SSH: Enabled
USB Host LAN : Enabled
Force to change default pwd to use Redfish/RESTful/other interfaces: No
max. 1x per system
PY TX2550 M7 Tower 4x3.5' basic and PY
Advanced Thermal Designis not available with LTO drives.
TX2550 M7 Tower 8x2.5' basic do not support
ATD options! For the detail, refer to the 'Therma
chapter'.
S26361-F3776-E440S26361-F3776-E445
Cool-safe ® Advanced Thermal design 40°CCool-safe ® Advanced Thermal design 45°C
enables the PRIMERGY Server to cope with enables the PRIMERGY Server to cope with temperatures from
temperatures from 5-40° in operating mode due to 5-45° in operating mode due to extended Fan settings
extended Fan settings
this setting can be activated ex factory onlythis setting can be activated ex factory only
max. 1x per systemmax. 1x per system
PYBETA1
Configuration Thermal Design 30°C(CTD30)
Sets the PRIMERGY server to support temperatures of up to
30 ° C in operating mode for the configuration with thermal
restriction.
Refer to Chapter15-Thermal Rule
this setting can be activated ex factory only
max. 1x per system
cnfgTX2550M7-20231117_hersPage 39 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
PYBCOM08
PY-COM08
Serial Port Option
RS-232-C for a RS-232-C Serial Port Interface
does NOT occupy PCI slot
max. 1x per system
PYBVAP08
PY-VAP08
Front VGA Option
VGA Interface
does NOT occupy PCI slot
max. 1x per system
will be EOL in CQ2'24
PYBTPM14
PY-TPM14
TPM 2.0 Module SPI
required for Microsoft Windows Server 2022 (host OS)
max. 1x per system
will be available in CQ1'24
PYBTPM20
PY-TPM20
TPM 2.0 Module V2
required for Microsoft Windows Server 2022 (host OS)
max. 1x per system
PYBNTPM
No TPM for WINSVR
Either PYBTPM14 or PYBNTPM is required
in ordering Windows Server 2022 OEM
max. 1x per system
When Windows Server 2022 is used as a host OS, PYBTPM14, PY-TPM14, PYBTPM20 or PY-TPM20 is
required. This requirement, however, can be waived if the end customer expresses their desire to
configure the server system without a TPM. In that case, No TPM for WINSVR can be selected.
When Windows Server 2022 is used as a guest OS, TPMs are not necessary.
OS support matrix:
PYBTPM14PYBTPM20
Operating system for host OSPY-TPM14PY-TPM20
Windows Server 2022requiredrequired
Windows Server 2019supportedsupported
Windows Server 2016supported-
Red Hat Enterprise Linux 8supportedsupported
Red Hat Enterprise Linux 7supportedsupported
SUSE Linux Enterprise Server 15--
VMware ESXi 7.0supportedsupported
VMware ESXi 6.7supported-
PYBTPM14/PY-TPM14 are currently available when will be EOL in CQ2'24
PYBTPM20/PY-TPM20 will be an alternative in CQ1'24
because new TPM supports mandatory to fit to new Windows requirement
New TPM are backward compatible with former TPMs.
PY-FOP17
4U Rack Front Bezel
Front Bezel on front Base
max. 1x per system
Your server is ready
cnfgTX2550M7-20231117_hersPage 40 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
Chapter 20 - Thermal Rule
Basic Model(PYT2557T3N / PYT2557T2N) ATD40 and ATD45 can't be supported.
Basic model
CPUMemoryDrive bayOption cardAmbient
4x3.5"8x3.5"8x2.5"LP PCIe / Nvidia T400FH PCIe / GPGPU on PCI RiserTemp.
No limitation
No limitationNo limitationLevel1-6 / Nvidia T400Not support
35C
Basic model for PCIe Level7
CPUMemoryDrive bayOption cardAmbient
4x3.5"8x3.5"8x2.5"LP PCIe / Nvidia T400FH PCIe / GPGPU on PCI RiserTemp.
CPU A
16GB - 64GB DDR5
on board SATA or RAID
CPU B
controller on slot1.
Level1-7 / Nvidia T400Not support
30C
CPU C
CPU D
Not supportNot support
* Need to select Configuration Thermal Design 30℃(PYBETA1)
Standard Model(PYT2557TAN/PYT2557TBN/PYT2557TCN/PYT2557R3N/PYT2557R2N/PYT2557RAN)
Standard model for ATD45
CPUMemoryDrive bayOption cardAmbient
LP PCIe / Nvidia T400FH PCIe / GPGPU on PCI RiserTemp.
No limitation
No limitationNo limitationLevel1-4 / Nvidia T400Not support
45C
* SSD support only. HDD can't be supported. LTO can't be supported.
Standard model for ATD40
CPUMemoryDrive bayOption cardAmbient
LP PCIe / Nvidia T400FH PCIe / GPGPU on PCI RiserTemp.
No limitation
No limitationNo limitationLevel1-5 / Nvidia T400Not support
40C
* SSD support only. HDD can't be supported. LTO can't be supported.
Standard model
CPUMemoryDrive bayOption cardAmbient
LP PCIe / Nvidia T400GPGPU on PCI Riser / FH PCIeTemp.
No limitation
No limitationNo limitationLevel1-6 / Nvidia T400Not support
35C
Standard model for FH PCIe/GPGPU on PCI Riser
CPUMemoryDrive bayOption cardAmbient
LP PCIe / Nvidia T400GPGPU on PCI Riser / FH PCIeTemp.
No limitation No limitation
No limitation
Level1-6 / Nvidia T400
GPGPU Group A / Level1-6
SSD only
GPGPU Group B / Level1-6
30C
* Need to select Configuration Thermal Design 30℃(PYBETA1)
Standard model for PCIe Level7
CPUMemoryDrive bayOption cardAmbient
8x3.5"12x3.5"8x2.5"LP PCIe / Nvidia T400FH PCIe / GPGPU on PCI RiserTemp.
CPU A
16GB - 64GB DDR5
on board SATA or RAID
CPU B
controller on slot1.
Level1-7 / Nvidia T400Not support
30C
CPU C
CPU D
Not supportNot support
* Need to select Configuration Thermal Design 30℃(PYBETA1)
cnfgTX2550M7-20231117_ermalPage 41 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
Option card: PCIe Level for Thermal condition
Card
RAID/SASPDUAL CP100
PDUAL CP300
PSAS CP600e FH / LP
PSAS CP600i LP
PSAS CP600i LP for LTO
PRAID CP600i LP
PRAID EP640i LP
PRAID EP680i LP / NVMe FH / LP
PRAID EP680e RAID Contr. FH/LP
PSAS CP2100-8i LP
PSAS CP2200-16i LP / NVMe FH / LP
PSAS CP 2200-16i LP for LTO
PRAID EP3252-8i LP
PRAID EP3254-8i LP
PRAID EP3258-16i LP / NVMe FH / LP
PRAID EP740i LP / NVMe FH / LP
PFC EP LPe31000 1x 16Gb FH / LP
PFC EP LPe31002 2x 16Gb FH / LP
PFC EP LPe35000 1X 32GFC PCIe v4 / LP
PFC EP LPe35002 2X 32GFC PCIe v4 / LP
PFC EP LPe36000 1X 32GFC PCIe v4 / LP
PFC EP LPe36002 2X 32GFC PCIe v4 / LP
PFC EP QLE2690 1x 16Gb FH / LP
PFC EP QLE2692 2x 16Gb FH / LP
PFC EP QLE2770 1X 32GFC PCIe v4 / LP
PFC EP QLE2772 2X 32GFC PCIe v4 / LP
PFC EP QLE2870 1X 32GFC PCIe v4 / LP
PFC EP QLE2872 2X 32GFC PCIe v4 / LP
PLAN CP 4x1Gbit Cu Intel I350-T4 LP
PLAN EP E810-CQDA2 2X 100G QSFP28 LP
PLAN EP E810-XXVDA2 2X 25G SFP28 FH / LP
PLAN EP E810-XXVDA4 4X 25G SFP28 LP
PLAN EP MCX6-DX 100Gb 2p QSFP28 LP
PLAN EP X710-DA2 2x10Gb SFP+ FH / LP
PLAN EP X710-DA4 4x10Gb SFP+ FH / LP
PLAN EP X710-T2L 2X 10GBASE-T FH / LP
PLAN EP X710-T4L 4X 10GBASE-T FH / LP
PLAN CP BCM5719-4P 4X 1000BASE-T PCIe FH / LP
PLAN EP P210P 2x10Gb SFP FH / LP
PLAN EP P210TP 2X 10GBASE-T PCIe FH / LP
PLAN EP MCX6-LX 25Gb 2p SFP28 PCIe FH / LP
PLAN EP P225P 25Gb 2p SFP28 PCIe FH / LP
PLAN EP P2100G 100Gb 2p QSFP56 PCIe LP
Product Number
PYBVG4A8
PYBVG4L1
PYBVG4A4
PYBVG4A5
PYBVG4A1
PYBVG4L2
PYBGP4A10
PYBVG4A7
PYBGP4H11
PYBVG4A2
PYBVG4L3
Product Number
FH
PYBDMCP24
PYBDMCP35
PYBSC4FAE
- / PYBSR4C62
PYBSR4C6E
- / PYBSC4MA2
FC
LAN
- / PYBSR4MA4
(TBD)
S26361-F5596-E1
S26361-F5596-E2
PYBFC421
PYBFC422
PYBFC441
PYBFC442
S26361-F5580-E1
S26361-F5580-E2
PYBFC411
PYBFC412
PYBFC431
PYBFC432
-
PYBLA432
PYBLA402
PYBLA404
PYBLA412
S26361-F3640-E2
S26361-F3640-E4
PYBLA342
PYBLA344
PYBLA284
PYBLA3J2
PYBLA3K2
PYBLA4024
PYBLA3H2
PYBLA442
LP
PYBDMCP24L
PYBDMCP35L
PYBSC4FAEL
PYBSC4FAL
PYBSC4FA2L
PYBSR4FAL
PYBSR4C63L
PYBSR4C6L / PYBSR4C62L
PYBSR4C6EL
PYBSC3MA2L
PYBSC4MA1L / PYBSC4MA2L
PYBSC4MA3L
PYBSR4MA1L
PYBSR4MA2L
PYBSR4MA3L / PYBSR4MA4L
(TBD)
S26361-F5596-E201
S26361-F5596-E202
PYBFC421L
PYBFC422L
PYBFC441L
PYBFC442L
S26361-F5580-E201
S26361-F5580-E202
PYBFC411L
PYBFC412L
PYBFC431L
PYBFC432L
S26361-F4610-E204
PYBLA432L
PYBLA402L
PYBLA404L
PYBLA412L
S26361-F3640-E202
S26361-F3640-E204
PYBLA342L
PYBLA344L
PYBLA284L
PYBLA3J2L
PYBLA3K2L
PYBLA402L4
PYBLA3H2L
PYBLA442L
PCIe Level
Level4
Level5
Level3
Level3
Level3
Level3
Level3
Level3
Level3
Level3
Level4
Level4
Level4
Level4
Level4
Level4
Level3
Level3
Level4
Level4
Level4
Level4
Level3
Level3
Level4
Level4
Level4
Level4
Level1
Level7
Level5
Level7
Level7
Level1
Level3
Level2
Level3
Level1
Level3
Level5
Level5
Level3
Level5
Option card: GPGPU Group
GroupCard
NVIDIA A2
NVIDIA L4
NVIDIA A16
NVIDIA A30
Group A
NVIDIA A40
NVIDIA L40
NVIDIA A100 80GB
NVIDIA RTX A4500
NVIDIA H100
Group B
NVIDIA RTX A6000
NVIDIA RTX 6000
S
cnfgTX2550M7-20231117_ermalPage 42 of 43
PRIMERGY TX2550 M7
System configurator and
order information guide
Date of changeConfigurator revisionFolder / order code / descriptionWhat has been changed / commentName
17.11.2023
13.11.2023
26.10.2023
25.10.2023
24.10.2023
19.10.2023
18.10.2023
16.10.2023
13.10.2023
13.10.2023
13.10.2023
04.10.2023
03.10.2023
03.10.2023
22.09.2023
20.09.2023
1.51
1.50
1.49
1.48
1.47
1.46
1.45
1.44
1.43
1.43
1,42
1.41
1.40
1.39
1,38
1,37
LAN, FC_IB
19.09.2023
14.09.2023
12.09.2023
08.09.2023
04.09.2023
30.08.2023
28.08.2023
28.08.2023
31.07.2023
31.07.2023
28.07.2023
20.07.2023
1.36
1.35
1.34
1,33
1,32
1.31
1.30
1.29
1.28
1.27
1.26
1.25
19.07.2023
14.07.2023
12.07.2023
11.07.2023
04.07.2023
04.07.2023
30.06.2023
29.06.2023
22.06.2023
15.06.2023
13.06.2023
07.06.2023
1.24
1.23
1.22
1.21
1.20
1.19
1.18
1.17
1.16
1.15
1.14
1.13
06.06.2023
05.06.2023
02.06.2023
02.06.2023
02.06.2023
02.06.2023
31.05.2023
30.05.2023
23.05.2023
22.05.2023
16.05.2023
15.05.2023
26.04.2023
1.12
1.11
1.10
1.09
1.08
1.07
1.06
1.05
1.04
1.03
1.02
1.01
1.0
QLE287x released.
Change schedule info of MCX6-LX and Broadcom 25/100G cards
Other (iRMC)Add "iRMC standard/legacy Option" PYBSSS3 in others sheet.
RAMRmoved DDR5 5600 memory
HDD_SSDupdated the description about max qty for M.2 SATA/PCIe drives.
RAMAdded DDR5 Registered DIMM 5600MHz
HDD_SSDreleased SED HDD/SSD
RAIDupdated Note for Intel VROC (SATA RAID)
GFX_FPGAAdd L40S/RTX 4000
HDD_SSDupdated availability schedule
RAIDreleased Intel VROC (VMD NVMe RAID)
HDD_SSDupdated the EOL informaiton for PCIe-SSD
LANAdd I350-T2 PCIe
ODD, othersAdd new order code for half height ODDs, and current order code will be EOL
Add new TPM
RAIDreleased Intel VROC (SATA RAID)
HDD_SSDadded the limitation about VROC for PCIe-SSD
HDD_SSD, HDD_SSD (short depth)updated availability schedule
added the following drives as new products
-Samsung PM1653 as SSD SAS 2.5"
-Samsung PM897a/PM893a as SSD SATA 2.5"/3.5"
Energy Staradded E-Star Fam1/Fam2 Certification for ENERGY STAR V4.0
RAID, backupupdated availability schedule
ThermalModified thermal rule for FH PCIe/GPGPU on PCI Riser for clear information
added the EOL status for HDD SAS 15K and HDD 2.5" BC-SATA/SAS
HDD_SSD
updated availability schedules for SSD SAS "PM7"
HDD_SSD
HD_SSD, Thermaladded PDUAL CP300
PYBDMCP35, PYBDMCP35L, PY-DMCP35
PCI_riser_cardchanged chapter name to ’PCI_riser_card’ and updated description
ThermalAdding MCX6-LX 25G and P(N)225P, P(N)2100G info to Thermal sheet
HD_SSDrevised the order codes for Kioxia CM7 15.36TB
HD_SSDadded the PCIe-SSD "kioxia CM7 series"
base, PCI_RiserSeparating PCI_Riser section to Chapter 14 from Chapter 1 - base unit
LANAdding Broadcom 25G/100G cards.
Adding NVIDIA 25G cards.
Deleting E810-CQDA2 and MCX6-DX 100G FH cards because thermal level is 7
and cannot be used it as FH.
GFX_FPGADelete A30X/A100X.
FC_IBDelete the restriction of QLE277x because System T50 includes these cards and
no issues.
ThermalRevice the limitation for RTX A6000
RAIDupdated availability schedule
GFX_FPGAAdded the RTX 6000
ThermalAdded the limitation for RTX A6000
othersNo TPM for WINSVR added
ThermalModified for clear information
BaseRemoved '1x USB 3.1 Gen1(type A)' from Interfaces internal
HD_cageRemoved availability schedule for PYBBA28ST
GFX_FPGAL4/L40
updated availability schedule
RAIDadded Intel VROC (SATA RAID)
added Intel VROC Upgrade Key
PYBRLVR02, PY-RLVR02
updated availability schedule
GFX_FPGAUpdated NVLink and L4 and L40, H100.
HD_cageRemoved 'except for PCIeSSDs'
HD_SSDupdated availability schedule
ThermalAdded H100 limitation.
LANChange max number of Broadcom 10G LAN P210P, P210TP LP cards from 6 to
4.
This is due to SA:233766419. Slot#3 and slot#10 cannot be used.
HD_cageRemove the limitation for the number of disks from
PYBBA24PJ/PYBBA24PK/PYBCBE024/PYBCBE025
HD_cageAdded PY-BA34SA/PY-BA34SB/PY-BA28SQ/PY-BA28SR/PY-BA28SS/PY-
BA28ST/PY-BA24PJ/PY-BA24PK/PY-CBE024/PY-CBE025
HD_cageRemove the limitation for the number of disks from PYBBA28SS
updated availability schedule for PYBBA28ST
ThermalRevice the detail
HD_SSDremoved the BC-SATA 20TB due to release cancel
HD_SSDchanged the max qty from "2" to "1" for M.2 SSD due to not support of VROC
RAID, backupupdated availability schedule
1st release
F. Kanega
H. Ogino
H. Konno
Y. Sugiyama
T. Sudou
a
T. Sudou
T. Sudou
Y. Sugiyama
F. Kanega
H. Konno
T. Sudou
Y. Sugiyama
Y. Sugiyama
T. Sudou
Y. Sugiyama
Y. Sugiyama
T. Sudou
F. Kanega
Y. Sugiyama
Y. Sugiyama
F. Kanega
S. Fujita
T. Sudou
a
S. Fujita
K. Nishihara
S. Fujita
S. Fujita
T. Sudou
a
T. Sudou
M. Takaoka/T. Sasaki
S. Fujita
T. Sudou
S. Fujita
F. Kanega
S. Fujita
S. Fujita
S. Fujita
S. Fujita
Y. Sugiyama
Y. Sugiyama
T. Sudou
S. Fujita
cnfgTX2550M7-20231117_ange_historyPage 43 of 43