Provolt™ Series Dual Relay Passive

Infrared (PIR) Occupancy Sensors

Light Pipe

DESCRIPTION

The Leviton Provolt™ Series Dual Relay

Occupancy Sensors combine line voltage dual

• Uses industry-exclusive digital (4 element)

FEATURES

relay occupancy sensors and photocells into

a self-contained unit. The integrated design

unwanted sources such as HVAC systems

PIR circuitry for fewer false triggers from

alleviates the need for separate power pack and

• A Fresnel lens establishes dozens of

occupancy sensor wiring making it a low-cost,

detection zones requiring the heat source

efficient energy solution for new construction and

to move from one zone to another to

retrofits. For true daylight harvesting applications,

integrated photocells provide consistent daylight

• Auto-temperature adjusts tech sensitivity

trigger the sensor

design levels by actively switching the connected

load(s) ON and OFF in response to available

• Auto-adapting: time delay and sensitivity

for optimal detection/operation

natural light to maximize energy savings. Vacancy

are continually adjusted to occupancy

timers continually analyze and adjust to changing

• Vacancy sensing time outs:

pattern of use

conditions using the latest microprocessor-based

- Delayed OFF timer

technology to optimize performance. Auto-ON/

- Exclusive walk-through feature

auto-OFF automatically turns lights ON and

• Output short circuit protection

keeps them ON when occupancy is detected and

• Industry-exclusive self-configuring local

automatically turns lights OFF when the space

manual switch input: momentary or

is vacant or unoccupied. Wire terminals allow for

simple connection to a line-voltage circuit and are

• Presentation mode allows user to turn lights

maintained switches are supported

ideal for existing buildings with limited access to

OFF and keep them OFF while the room is

wiring and new construction.

• Adjustable time delay: 30s, 5min, 10min,

occupied

APPLICATIONS

20min, 30min

• Can be used to comply with ASHRAE 90.1

• Test mode for simplified commissioning

and 2016 California Title 24, Part 6 occupancy/

• Manual switch and emergency override are

vacancy sensing, automatic shut-off, daylight

provided for flexibility.

Class 1 and Class 2 circuits. Class 2 circuits

• Auto-ON/auto-OFF

harvesting and stairwell requirements

• Industry-exclusive “fail-safe” circuitry: in the

• Manual-ON/auto-OFF

event of product failure, return-to-closed

• Dual relay modes include:

feature causes the relay to default ON which

- Fan control

- Auto-ON/manual-ON

• Industry-exclusive H.I.S. (High Inrush Stability)

eliminates life safety concerns

- Stairwell control

technology designed to handle today’s

- Step dimming—alternating daylighting

high inrush electronic ballast loads and offer

- Step dimming—load 1 primary

levels

unmatched durability and service

Leviton Manufacturing Co., Inc. Global Headquarters

201 North Service Road, Melville, NY 11747-3138 tech line 800-824-3005 fax 800-832-9538

©2017 Leviton Manufacturing Co., Inc. All rights reserved. Subject to change without notice.

s

r

o

s

n

e

S

c

y

n

a

p

u

c

c

O

)

R

I

P

(

d

e

r

a

r

f

n

I

e

v

i

s

s

P

a

a

y

l

e

R

l

a

u

D

s

e

i

r

e

S

t

l

v

o

r

o

P

PRODUCT DATA

FEATURES

• Robust and reliable mechanically held latching

relay provides dependability and robust performance

for all load types and provides energy savings over

electronically held relays

• Field of view: units from 450 to 1,500 square feet

available

• Lenses are easily replaceable and color-coded—

blue (high-density) and red (mid-range) for contractors

and end-users to easily identify lenses from the ground

• Visual LED indicators for all states:

- Red—blinks when infrared is detecting motion and

during photocell manual calibration; solid during

device malfunction

- Yellow—blinks during test mode; solid with

emergency/BMS input

- Blue—blinks when knob settings are changed

and during photocell override

- Green—solid during auto calibration

RATINGS AND TESTING

• Factory-calibrated, zero-crossing circuitry for extended

life of the relay

• Tested to exceed 1 million switching cycles under

standard loads

• Multiple compliance and regulatory UL testing—

consult factory for details

• Passed rigorous NEMA 410 testing for electronic

ballast rating

• BMS Input/Emergency Override: UL 924 listed for

Emergency and Egress lighting control

PHOTOCELL OPERATION

Open Loop - Angled Light Pipe

Note: Long side of angled light pipe must

face toward natural light source (window)

OPEN LOOP

7

6

OFF trigger point

Lights turn OFF

Noon

5

4

3

2

DDL

ON trigger point

Lights turn ON

1

Lights ON

Night time

0

Dawn

Dusk

Closed Loop - Flat Light Pipe

CLOSED LOOP

7

2.5x DDL

6

Zone OFF

5

4

Noon

3

Dawn

Dusk

2

1

Lights ON

DDL

1.25x DDL

0

Zone ON

Photocell Features

• Daylight harvesting applications:

- Auto-calibration (automatic daylight

calibration): photocell intelligently measures

light levels to determine optimal daylight

design levels for closed loop applications

- Closed loop: photocell detects total

measurement of both natural and artificial

light in the space

- Open loop: photocell detects measurement

of natural light only (sunlight from window

or skylight

• Adjustable daylight design levels: Normal (OFF),

Manual (ON/OFF) and Auto Calibration

• Integrated photocell tested to less than 1 Fc

accuracy

INSTALLATION

• Easy installation into junction boxes with Leviton-

exclusive screw guides, coasters and terminal

blocks

• Front cover snaps on and off for ease of

installation

PHOTOCELL PLACEMENT*

Open Loop Application - Angled Light Pipe

O2C04

4

5

°

Light Fixture

Peak

Sensitivity

9’

4’

Closed Loop Application - Flat Light Pipe

O2C04

4’

Light Fixture

Window

68°

9’

Peak Sensitivity

Typical Dayligt Zone, about 10’

*May require more than one occupancy sensor for total room coverage

PRODUCT DATA

FIELD OF VIEWS

TOP VIEW

TOP VIEW

12

5

0

0

5

12

SIDE VIEW

SIDE VIEW

Minor Motion, Infrared

12

Major Motion, Infrared

12

9

7 5 3

0 3

5

7

9

12

0

O2C04-IDW

(High Density Lens - Blue)

Multi-Range Lens

(Included with PIR Model - Red)

DIMENSIONS

1.16”

1.09”

4.81”

(27.91mm)

(122.21mm)

0.94”

(24.06mm)

2.39”

(60.71mm)

INSTALLATION

4”x4” Cosmetic Adapter

Screw Guides

Angled light pipe

Flat light pipe

Sensors conveniently mount to a standard 4” x 4” square or octagon electrical

box per NEC standards.

Leviton Manufacturing Co., Inc. Global Headquarters

201 North Service Road, Melville, NY 11747-3138 tech line 800-824-3005 fax 800-832-9538

©2017 Leviton Manufacturing Co., Inc. All rights reserved. Subject to change without notice.

TOP VIEW

20

10

0

10

20

SIDE VIEW

8

0

20 15 11

9

5.6 3 0 3 5.6 9

11

15

20

O2C15-IDW

(Extended Range Lens - Black)

s

r

o

s

n

e

S

c

y

n

a

p

u

c

c

O

)

R

e

I

r

P

e

(

H

d

s

e

r

e

a

o

r

G

f

n

e

I

l

t

e

i

v

T

i

s

r

s

a

b

P

a

e

d

y

i

a

S

l

e

R

l

a

u

D

s

e

i

r

e

S

t

l

v

o

r

o

P

(29.60mm)

PRODUCT DATA

SPECIFICATIONS

ELECTRICAL

Input Voltage120V, 50/60Hz

8A, Electronic

Ballast, 800W,

Tungsten,

800VA Ballast,

1/4 HP Motor

60-30ma

32-104° F (0-40° C)

-15-160° F (-26-71° C)

0-90% non-condensing

Can be used to comply with ASHRAE 90.1 and 2016

California Title 24, Part 6 occupancy/vacancy sensing,

automatic shut-off, daylight harvesting and stairwell

requirements, UL 773A (Occupancy Standard), UL 924

(Emergency Equipment), cUL listed, CE compliant, NOM

certified, RoHS compliant, NY LLC48 compliant

5-Year Limited Warranty

230V, 50Hz

6A/6AX, Electronic

Ballast,

Magnetic Ballast,

Tungsten,

1/3 HP Motor

277V, 50/60Hz

5A, Electronic

Ballast,

1200VA Ballast,

1/3 HP Motor

Load Rating

Current Consumption

ENVIRONMENTAL

Operating Temperature

Storage Temperature

Relative Humidity

OTHER

Listings

Warranty

ORDERING INFORMATION

CAT. PTION

O2C04-IDW

Passive Infrared Ceiling Mount Line Voltage Dual Relay Occupancy Sensor

w/Integrated Photocell, 450SF, 120-277V, high-density lens installed,

mid-range included

Passive Infrared Ceiling Mount Line Voltage Dual Relay Occupancy Sensor

w/Integrated Photocell, 1,500SF, 120-277V, extended range lens

installed, mid-range included

O2C15-IDW

Leviton Manufacturing Co., Inc. Global Headquarters

201 North Service Road, Melville, NY 11747-3138 tel 800-323-8920 fax 800-832-9538 tech line (8:30AM-7:00PM ET Mon-Fri) 800-824-3005

Leviton Manufacturing Co., Inc. Energy Management, Controls and Automation

20497 SW Teton Avenue, Tualatin, OR 97062 tel 800-736-6682 fax 503-404-5594 tech line (6:00AM-4:00PM PT Mon-Fri) 800-959-6004

Visit our Website at: /provolt

©2017 Leviton Manufacturing Co., Inc. All rights reserved. Subject to change without notice.

G-9150A/L17-aa

REV DEC 2017

2024年10月8日发(作者:郜智杰)

Provolt™ Series Dual Relay Passive

Infrared (PIR) Occupancy Sensors

Light Pipe

DESCRIPTION

The Leviton Provolt™ Series Dual Relay

Occupancy Sensors combine line voltage dual

• Uses industry-exclusive digital (4 element)

FEATURES

relay occupancy sensors and photocells into

a self-contained unit. The integrated design

unwanted sources such as HVAC systems

PIR circuitry for fewer false triggers from

alleviates the need for separate power pack and

• A Fresnel lens establishes dozens of

occupancy sensor wiring making it a low-cost,

detection zones requiring the heat source

efficient energy solution for new construction and

to move from one zone to another to

retrofits. For true daylight harvesting applications,

integrated photocells provide consistent daylight

• Auto-temperature adjusts tech sensitivity

trigger the sensor

design levels by actively switching the connected

load(s) ON and OFF in response to available

• Auto-adapting: time delay and sensitivity

for optimal detection/operation

natural light to maximize energy savings. Vacancy

are continually adjusted to occupancy

timers continually analyze and adjust to changing

• Vacancy sensing time outs:

pattern of use

conditions using the latest microprocessor-based

- Delayed OFF timer

technology to optimize performance. Auto-ON/

- Exclusive walk-through feature

auto-OFF automatically turns lights ON and

• Output short circuit protection

keeps them ON when occupancy is detected and

• Industry-exclusive self-configuring local

automatically turns lights OFF when the space

manual switch input: momentary or

is vacant or unoccupied. Wire terminals allow for

simple connection to a line-voltage circuit and are

• Presentation mode allows user to turn lights

maintained switches are supported

ideal for existing buildings with limited access to

OFF and keep them OFF while the room is

wiring and new construction.

• Adjustable time delay: 30s, 5min, 10min,

occupied

APPLICATIONS

20min, 30min

• Can be used to comply with ASHRAE 90.1

• Test mode for simplified commissioning

and 2016 California Title 24, Part 6 occupancy/

• Manual switch and emergency override are

vacancy sensing, automatic shut-off, daylight

provided for flexibility.

Class 1 and Class 2 circuits. Class 2 circuits

• Auto-ON/auto-OFF

harvesting and stairwell requirements

• Industry-exclusive “fail-safe” circuitry: in the

• Manual-ON/auto-OFF

event of product failure, return-to-closed

• Dual relay modes include:

feature causes the relay to default ON which

- Fan control

- Auto-ON/manual-ON

• Industry-exclusive H.I.S. (High Inrush Stability)

eliminates life safety concerns

- Stairwell control

technology designed to handle today’s

- Step dimming—alternating daylighting

high inrush electronic ballast loads and offer

- Step dimming—load 1 primary

levels

unmatched durability and service

Leviton Manufacturing Co., Inc. Global Headquarters

201 North Service Road, Melville, NY 11747-3138 tech line 800-824-3005 fax 800-832-9538

©2017 Leviton Manufacturing Co., Inc. All rights reserved. Subject to change without notice.

s

r

o

s

n

e

S

c

y

n

a

p

u

c

c

O

)

R

I

P

(

d

e

r

a

r

f

n

I

e

v

i

s

s

P

a

a

y

l

e

R

l

a

u

D

s

e

i

r

e

S

t

l

v

o

r

o

P

PRODUCT DATA

FEATURES

• Robust and reliable mechanically held latching

relay provides dependability and robust performance

for all load types and provides energy savings over

electronically held relays

• Field of view: units from 450 to 1,500 square feet

available

• Lenses are easily replaceable and color-coded—

blue (high-density) and red (mid-range) for contractors

and end-users to easily identify lenses from the ground

• Visual LED indicators for all states:

- Red—blinks when infrared is detecting motion and

during photocell manual calibration; solid during

device malfunction

- Yellow—blinks during test mode; solid with

emergency/BMS input

- Blue—blinks when knob settings are changed

and during photocell override

- Green—solid during auto calibration

RATINGS AND TESTING

• Factory-calibrated, zero-crossing circuitry for extended

life of the relay

• Tested to exceed 1 million switching cycles under

standard loads

• Multiple compliance and regulatory UL testing—

consult factory for details

• Passed rigorous NEMA 410 testing for electronic

ballast rating

• BMS Input/Emergency Override: UL 924 listed for

Emergency and Egress lighting control

PHOTOCELL OPERATION

Open Loop - Angled Light Pipe

Note: Long side of angled light pipe must

face toward natural light source (window)

OPEN LOOP

7

6

OFF trigger point

Lights turn OFF

Noon

5

4

3

2

DDL

ON trigger point

Lights turn ON

1

Lights ON

Night time

0

Dawn

Dusk

Closed Loop - Flat Light Pipe

CLOSED LOOP

7

2.5x DDL

6

Zone OFF

5

4

Noon

3

Dawn

Dusk

2

1

Lights ON

DDL

1.25x DDL

0

Zone ON

Photocell Features

• Daylight harvesting applications:

- Auto-calibration (automatic daylight

calibration): photocell intelligently measures

light levels to determine optimal daylight

design levels for closed loop applications

- Closed loop: photocell detects total

measurement of both natural and artificial

light in the space

- Open loop: photocell detects measurement

of natural light only (sunlight from window

or skylight

• Adjustable daylight design levels: Normal (OFF),

Manual (ON/OFF) and Auto Calibration

• Integrated photocell tested to less than 1 Fc

accuracy

INSTALLATION

• Easy installation into junction boxes with Leviton-

exclusive screw guides, coasters and terminal

blocks

• Front cover snaps on and off for ease of

installation

PHOTOCELL PLACEMENT*

Open Loop Application - Angled Light Pipe

O2C04

4

5

°

Light Fixture

Peak

Sensitivity

9’

4’

Closed Loop Application - Flat Light Pipe

O2C04

4’

Light Fixture

Window

68°

9’

Peak Sensitivity

Typical Dayligt Zone, about 10’

*May require more than one occupancy sensor for total room coverage

PRODUCT DATA

FIELD OF VIEWS

TOP VIEW

TOP VIEW

12

5

0

0

5

12

SIDE VIEW

SIDE VIEW

Minor Motion, Infrared

12

Major Motion, Infrared

12

9

7 5 3

0 3

5

7

9

12

0

O2C04-IDW

(High Density Lens - Blue)

Multi-Range Lens

(Included with PIR Model - Red)

DIMENSIONS

1.16”

1.09”

4.81”

(27.91mm)

(122.21mm)

0.94”

(24.06mm)

2.39”

(60.71mm)

INSTALLATION

4”x4” Cosmetic Adapter

Screw Guides

Angled light pipe

Flat light pipe

Sensors conveniently mount to a standard 4” x 4” square or octagon electrical

box per NEC standards.

Leviton Manufacturing Co., Inc. Global Headquarters

201 North Service Road, Melville, NY 11747-3138 tech line 800-824-3005 fax 800-832-9538

©2017 Leviton Manufacturing Co., Inc. All rights reserved. Subject to change without notice.

TOP VIEW

20

10

0

10

20

SIDE VIEW

8

0

20 15 11

9

5.6 3 0 3 5.6 9

11

15

20

O2C15-IDW

(Extended Range Lens - Black)

s

r

o

s

n

e

S

c

y

n

a

p

u

c

c

O

)

R

e

I

r

P

e

(

H

d

s

e

r

e

a

o

r

G

f

n

e

I

l

t

e

i

v

T

i

s

r

s

a

b

P

a

e

d

y

i

a

S

l

e

R

l

a

u

D

s

e

i

r

e

S

t

l

v

o

r

o

P

(29.60mm)

PRODUCT DATA

SPECIFICATIONS

ELECTRICAL

Input Voltage120V, 50/60Hz

8A, Electronic

Ballast, 800W,

Tungsten,

800VA Ballast,

1/4 HP Motor

60-30ma

32-104° F (0-40° C)

-15-160° F (-26-71° C)

0-90% non-condensing

Can be used to comply with ASHRAE 90.1 and 2016

California Title 24, Part 6 occupancy/vacancy sensing,

automatic shut-off, daylight harvesting and stairwell

requirements, UL 773A (Occupancy Standard), UL 924

(Emergency Equipment), cUL listed, CE compliant, NOM

certified, RoHS compliant, NY LLC48 compliant

5-Year Limited Warranty

230V, 50Hz

6A/6AX, Electronic

Ballast,

Magnetic Ballast,

Tungsten,

1/3 HP Motor

277V, 50/60Hz

5A, Electronic

Ballast,

1200VA Ballast,

1/3 HP Motor

Load Rating

Current Consumption

ENVIRONMENTAL

Operating Temperature

Storage Temperature

Relative Humidity

OTHER

Listings

Warranty

ORDERING INFORMATION

CAT. PTION

O2C04-IDW

Passive Infrared Ceiling Mount Line Voltage Dual Relay Occupancy Sensor

w/Integrated Photocell, 450SF, 120-277V, high-density lens installed,

mid-range included

Passive Infrared Ceiling Mount Line Voltage Dual Relay Occupancy Sensor

w/Integrated Photocell, 1,500SF, 120-277V, extended range lens

installed, mid-range included

O2C15-IDW

Leviton Manufacturing Co., Inc. Global Headquarters

201 North Service Road, Melville, NY 11747-3138 tel 800-323-8920 fax 800-832-9538 tech line (8:30AM-7:00PM ET Mon-Fri) 800-824-3005

Leviton Manufacturing Co., Inc. Energy Management, Controls and Automation

20497 SW Teton Avenue, Tualatin, OR 97062 tel 800-736-6682 fax 503-404-5594 tech line (6:00AM-4:00PM PT Mon-Fri) 800-959-6004

Visit our Website at: /provolt

©2017 Leviton Manufacturing Co., Inc. All rights reserved. Subject to change without notice.

G-9150A/L17-aa

REV DEC 2017

发布评论