WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: READ

AND SAVE THESE INSTRUCTIONS

Installation work and electrical wiring must be done by qualified person(s) in accordance with applicable codes and standards (ANSI/NFPA 70-1999), including

fire-rated construction.

Use this unit only in the manner intended by the manufacturer. If you have any questions contact the manufacturer.

After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor on one side of the

outlet box and ungrounded conductor on the other side of the outlet box. The splices, after being made, should be turned upward and pushed carefully up

into the outlet box.

WARNING: Before you begin installing the fan, servicing or cleaning unit, Switch power off at Service panel and lock service disconnecting means to prevent

power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a

tag, to the service panel.

Be cautious! Read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.

When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7 feet from the floor to the

trailing edge of the blade.

WARNING: To Reduce The Risk Of Fire, Electric Shock, or Personal Injury, Mount To Outlet Box Marked “Acceptable for Fan Support of

15.9 kg (35 lbs) or less” And Use Mounting Screws Provided With The Outlet Box.

CAUTION: For Compliance with Local Codes and Regulations, If Installing The Secondary Support Safety Cable in the U.S., Do Not Re-

move Knockouts In The Outlet Box. Mount the secondary support safety cable through the reserved nail/screw hole on the outlet box to

the building structure (or the ceiling joist).

WARNING: To reduce the risk of personal injury, do not bend blade holders during installation to motor, balancing or during cleaning. Do not insert foreign

object between rotating blades.

Attach the mounting bracket using only the hardware supplied with the outlet box.

WARNING: To reduce the risk of fire or electric shock, this fan must be installed with an isolating wall control/switch.

WARNING:To reduce the risk of fire or electric shock, do not use this fan with any solid state fan speed control device, or variable speed control.

If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application.

Never place a switch where it can be reached from a tub or shower.

The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating equipment manufac-

turer’s guideline safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigera-

tion and Air Conditioning Engineers (ASHRAE) and the local code authorities.

CAUTION: To Reduce the Risk of Electric Shock, Disconnect the electrical supply circuit to the fan before installing the light kit.

All set screws must be checked and tightened where necessary before installation.

Tools Required for Assembly (not included): Electrical Tape, Phillips Screwdriver, Pliers, Safety Glasses,

Stepladder and Wire Strippers.

Customer Service

800-969-3347

Customer Service Center

7400 Linder Ave.

Skokie, IL 60077

© 2013 Monte Carlo Fan Company

2

8/13/2013

12

3

Before you begin installing the fan, Switch

power off at Service panel and lock service dis-

connecting means to prevent power from being

switched on accidentally. When the service dis-

connecting means cannot be locked, securely

fasten a prominent warning device, such as a

tag, to the service panel.

Before installing this fan make sure the outlet box is

properly installed to the house structure. To reduce

the risk of fire, electric shock, or personal injury,

mount to outlet box or supporting system acceptable

for fan support. (Mounting must support at least 35

lbs.)

Use metal outlet box suitable for fan support

(must support 35 lbs). Before attaching fan to

outlet box, ensure the outlet box is securley

fastened by at least two points to a structural

ceiling member ( a loose box will cause the fan

to wabble). Use only the screws provided

with the outlet box.

4

Downrod mount installation

yoke

5

Downrod

Canopy

6

Downrod

Cross

pin

Loosen the 2 set screws till you can not

feel them on inside of yoke.

Note: If install fan on vaulted ceiling,

make sure open end of mounting

bracket is installed facing the higher

point of the ceiling and make sure the

ceiling angle is not steeper

than 30º.

Keeper

pin

Canopy

disk

Remove Keeper pin and cross pin

from downrod. Place canopy and

caonpy disk cover over downrod.

Thread leadwires and safety

cable through downrod.

7

8

9

Place downrod into fan yoke.

Align the hole in the Downrod with the hole in

the Yoke. Insert the Pin through the Yoke and

Downrod until the point appears on the other

side.

Install the keeper to pin.

© 2013 Monte Carlo Fan Company

3

8/13/2013

10

11

12

Safety cable installation

Safety Cable

Lag Screw

safety

cable

washer

3” lag

screw

lock

washer

Tighten the 2 set screws on the yoke

once the downrod is in place.

Hang assembled fan from the mounting bracket in-

stalled to ceiling in previous step. Make sure the fan

is hanging straight. Rotate fan until the tab on the

Mounting bracket engages the slot on the Downrod

Ball. This must be done to prevent the fan body from

rotating when the blades are in motion.

For Canadian installation and for USA fan and light

kit combinations over 35 lbs, in both flush and

downrod modes the safety cable must be installed

into the house structure beams using 3” lag

screws, washers and lock washers provided. Make

sure that when the safety cable is fully extended

the lead wires are longer than the cable and no

stress is placed on the lead wires.

Note:If Installing The Secondary Support Safety

Cable in the U.S., Do Not Remove Knockouts In

The Outlet Box.

13

14

15

Make sure the studs protruding from the

bottom of the Mounting bracket are in-

stalled with threads all the way through

the bracket.

Make wiring connections as indicated

above. Connect black and blue wire from

fan to Black or (Hot) wire from house.

Connect White wire from Fan to White

(Neutral) wire from house. Connect

Ground leads from mounting bracket and

downrod to Ground lead from house.

Refer to Safety Tips section of manual.

Make wire connections to power source using wire nuts

provided. Make sure that no filiments are outside of

the wirenut. After making the wire connections, the

wires should be spread apart with the grounded con-

ductor and the equipment-grounding conductor on one

side of the outlet box and ungrounded conductor on the

other side of the outlet box.

16

17

Flush mount installation

Go to step 26

Cover

Ring

Lift Conopy allowing the 2 studs to

protrude through the canopy.

Next lift the cover ring and install knurled

nuts as shown. Tighten the knurled nuts

securely. The canopy should adjust for

any irregularity in the ceiling or Outlet

box.

Remove every other screw as circled

and save for later use.

Note: Flushmount is not available

with vaulted ceiling.

© 2013 Monte Carlo Fan Company

4

8/13/2013

18

19

20

“L” shape

slots

Install rubber pad between fan

body and canopy.

Remove side covers from canopy exposing

4 holes. 2 closed holes and 2 open “L”

shape holes and then Pass leadwires and

safety cable through the canopy.

Place canopy over fan body align-

ing holes.

Replace the 3 screws removed and

tighten securely. Check motor for

shipping stabilizers and remove if

present.

21

22

23

Hands free hook

Remove the all thread studs from the

lower part of the mounting bracket. Hang

fan from mounting bracket by the

hands free hook into a closed hole on

the edge of the : For

Canadian mounting refer to Step #12.

Take 4 screws from hardware pack

and install one on each side of

bracket to match the L slot screw

holes in canopy. Keep 2 screws for

later use.

Make wiring connections as indicated

above. Connect black and blue wire from

fan to Black or (Hot) wire from house.

Connect White wire from Fan to White

(Neutral) wire from house. Connect

Ground leads from mounting bracket and

downrod to Ground lead from house.

Refer to Safety Tips section of manual.

24

25

26

Make wire connections to power source using wire nuts

provided. Make sure that no filiments are outside of

the wirenut. After making the wire connections, the

wires should be spread apart with the grounded con-

ductor and the equipment-grounding conductor on one

side of the outlet box and ungrounded conductor on the

other side of the outlet box.

Lift fan to mounting bracket, aligning the “L”

shape holes with the screws on the mounting

bracket. Turn the fan clockwise to lock in

position. Install the other 2 screws included

in hardware bag and tighten all 4 securely.

Check the motor for shipping stabiliz-

ers and remove if present. Attach

blades using screws and washers in

hardware pack. Tighten screws se-

curely.

Note: Tighten set screws twice a

year.

© 2013 Monte Carlo Fan Company

5

8/13/2013

27

28

29

Loosen 2 screws and remove 1 screw

from motor plate. Save removed

screw for use later.

Install by twisting clockwise, add 1

screw removed step 27 to switch

housing plate. Tighten the 3 screws

securely.

Connect plug from fan to switch

house plug. Be sure plugs connection

snap together completely.

30

31

32

Loosen the pre installed screws of

switch housing plate. Save removed

screw for use later.

Connect white wire from fan to white

wire from light fixture. Then plug

blue wire from fan to black wire from

light fixture.

Install 3 screws to install light pan.

33

34

35

Install a JD 75 watt halogen bulb, bulb in-

cluded.

Caution: Do not replace bulb until it cools

down.

WARNING:Over lamping the fan will re-

sult in the fan lights shutting down until

the proper wattage of bulbs are installed.

Reset the lights by turning off the wall

switch, breaker,or by remote. Replace bulbs

with the correct wattage bulbs, turn the

power on.

Left hand side

(Forward)

Reverse switch

Right hand side

(Reverse)

Attach glass by locating dimples in

light fixture with the groves in glass

and twisting clockwise till tight.

Setting the reverse switch in the left hand

side will result in downward airflow and set-

ting the switch in the right hand side will re-

sult in upward airflow.

Note: Reverse switch must be set either

completely LEFT or completely Right for fan

to function. If the reverse switch is set in the

middle position, fan will not operate.

© 2013 Monte Carlo Fan Company

6

8/13/2013

T

ROUBLE

S

HOOTING

If you have difficulty operating your new ceiling fan, it may be the result of incorrect assembly, installation, or

wiring. In some cases, these installation errors may be mistaken for defects. If you experience any faults, please

check this Trouble Shooting Chart. If a problem cannot be remedied, or you are experiencing difficulty in installa-

tion, please call our Customer Service Center at the

number printed on your parts list insert sheet.

Warning: Before servicing or cleaning unit, Switch power off at Service panel and lock service discon-

necting means to prevent power from being switched on accidentally. When the service disconnecting

means cannot be locked, securely fasten a

prominent warning device, such as a tag, to the service panel.

Trouble

1. If fan does not start:

Suggested Remedy

main and branch circuit fuses or circuit breakers.

line wire connections to fan and switch wire connections in switch housing.

CAUTION: Make sure main power is turned off.

sure forward/reverse switch is firmly in up or down position. Fan will not operate

when switch is in the middle.

sure that shipping stabilizer tabs have been removed from motor.

to make sure all screws in motor housing are snug (not over tightened).

to make sure the screws which attach the fan blade holder to the motor are tight.

to make sure wire nut connectors in switch housing are not rattling against each

other or against the interior wall of the switch housing.

CAUTION: Make sure main power is turned off before entering switch housing.

using an optional Ceiling Fan Light Kit, check to be sure the screws securing the glass-

ware are finger tight. Check to be sure light bulb is tight in socket and not touching glass

shade(s). If vibration persists from glass, remove glass and install a 1/4" wide rubber band

on glass neck to act as an insulator. Replace glass and tighten screws against rubber band.

fan motors are sensitive to signals from Solid State variable speed controls. DO NOT

USE a Solid State variable speed control.

"break-in" period of 24 hours. Most noises associated with a new fan will disappear

after this period.

this is a downrod mount fan, make sure the ridge on mounting bracket engages the

notch in the downrod ball.

that all blades are screwed firmly into blade holders.

that all blade holders are tightened securely to motor.

sure that canopy and mounting bracket are tightened securely to ceiling junction box

and junction box is mounted firmly to ceiling joist.

fan wobble problems are caused when blade levels are unequal. Check this level by

selecting a point on the ceiling above the tip of one of the blades. Measure this distance from

blade tip to ceilng. Keeping measure within 1/8", rotate the fan until the next blade is posi-

tioned for measurement. Repeat for each blade. If all blade levels are not equal, you can ad-

just blade levels by the following procedure. To adjust a blade tip down, insert a washer (not

supplied) between the blade and blade holder at the screw closest to the motor. To adjust a

blade tip up, insert washer (not supplied) between the blade and blade holder at the two

screws farthest from the motor. Reverse the position of the washer if blades mount from top

of blade.

blade wobble is still noticeable, interchanging two adjacent (side by side) blades can re-

distribute the weight and possibly result in smoother operation.

blue wire from fan to make sure it is connected to hot wire from house.

for loose or disconnected wires in fan switch housing.

for loose or disconnected wires in light kit.

for faulty light bulbs.

WARNING:Over lamping the fan will result in the fan lights shutting down

until the proper wattage of bulbs are installed.

Reset the lights by turning off the wall switch, breaker,or by remote. Replace bulbs

with the correct wattage bulbs, turn the power on.

CAUTION: Make sure main power is turned off before entering switch housing.

2. If fan sounds noisy:

3. If fan wobbles:

4. If light does not work:

© 2013 Monte Carlo Fan Company

7

8/13/2013

Apr.2013

May.2013 CUL requirement

Aug.2013 dual mount

Jul.2014 logo on canopy

2024年10月11日发(作者:板凌蝶)

Owner’s Guide and Installation Manual

5DI52XXD/5DI52XXD-L Series Fan

UL Model No. : 5DI52

Attach sales receipt to this card and retain as your proof of purchase

DATE OF PURCHASE:

RETAILER NAME:

MODEL NUMBER:

RETAILER ADDRES

S:

To register your fixture, please visit our website

8.5 kgs

18.7 lbs

Total fan weight with light

WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: READ

AND SAVE THESE INSTRUCTIONS

Installation work and electrical wiring must be done by qualified person(s) in accordance with applicable codes and standards (ANSI/NFPA 70-1999), including

fire-rated construction.

Use this unit only in the manner intended by the manufacturer. If you have any questions contact the manufacturer.

After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor on one side of the

outlet box and ungrounded conductor on the other side of the outlet box. The splices, after being made, should be turned upward and pushed carefully up

into the outlet box.

WARNING: Before you begin installing the fan, servicing or cleaning unit, Switch power off at Service panel and lock service disconnecting means to prevent

power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a

tag, to the service panel.

Be cautious! Read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.

When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7 feet from the floor to the

trailing edge of the blade.

WARNING: To Reduce The Risk Of Fire, Electric Shock, or Personal Injury, Mount To Outlet Box Marked “Acceptable for Fan Support of

15.9 kg (35 lbs) or less” And Use Mounting Screws Provided With The Outlet Box.

CAUTION: For Compliance with Local Codes and Regulations, If Installing The Secondary Support Safety Cable in the U.S., Do Not Re-

move Knockouts In The Outlet Box. Mount the secondary support safety cable through the reserved nail/screw hole on the outlet box to

the building structure (or the ceiling joist).

WARNING: To reduce the risk of personal injury, do not bend blade holders during installation to motor, balancing or during cleaning. Do not insert foreign

object between rotating blades.

Attach the mounting bracket using only the hardware supplied with the outlet box.

WARNING: To reduce the risk of fire or electric shock, this fan must be installed with an isolating wall control/switch.

WARNING:To reduce the risk of fire or electric shock, do not use this fan with any solid state fan speed control device, or variable speed control.

If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application.

Never place a switch where it can be reached from a tub or shower.

The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating equipment manufac-

turer’s guideline safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigera-

tion and Air Conditioning Engineers (ASHRAE) and the local code authorities.

CAUTION: To Reduce the Risk of Electric Shock, Disconnect the electrical supply circuit to the fan before installing the light kit.

All set screws must be checked and tightened where necessary before installation.

Tools Required for Assembly (not included): Electrical Tape, Phillips Screwdriver, Pliers, Safety Glasses,

Stepladder and Wire Strippers.

Customer Service

800-969-3347

Customer Service Center

7400 Linder Ave.

Skokie, IL 60077

© 2013 Monte Carlo Fan Company

2

8/13/2013

12

3

Before you begin installing the fan, Switch

power off at Service panel and lock service dis-

connecting means to prevent power from being

switched on accidentally. When the service dis-

connecting means cannot be locked, securely

fasten a prominent warning device, such as a

tag, to the service panel.

Before installing this fan make sure the outlet box is

properly installed to the house structure. To reduce

the risk of fire, electric shock, or personal injury,

mount to outlet box or supporting system acceptable

for fan support. (Mounting must support at least 35

lbs.)

Use metal outlet box suitable for fan support

(must support 35 lbs). Before attaching fan to

outlet box, ensure the outlet box is securley

fastened by at least two points to a structural

ceiling member ( a loose box will cause the fan

to wabble). Use only the screws provided

with the outlet box.

4

Downrod mount installation

yoke

5

Downrod

Canopy

6

Downrod

Cross

pin

Loosen the 2 set screws till you can not

feel them on inside of yoke.

Note: If install fan on vaulted ceiling,

make sure open end of mounting

bracket is installed facing the higher

point of the ceiling and make sure the

ceiling angle is not steeper

than 30º.

Keeper

pin

Canopy

disk

Remove Keeper pin and cross pin

from downrod. Place canopy and

caonpy disk cover over downrod.

Thread leadwires and safety

cable through downrod.

7

8

9

Place downrod into fan yoke.

Align the hole in the Downrod with the hole in

the Yoke. Insert the Pin through the Yoke and

Downrod until the point appears on the other

side.

Install the keeper to pin.

© 2013 Monte Carlo Fan Company

3

8/13/2013

10

11

12

Safety cable installation

Safety Cable

Lag Screw

safety

cable

washer

3” lag

screw

lock

washer

Tighten the 2 set screws on the yoke

once the downrod is in place.

Hang assembled fan from the mounting bracket in-

stalled to ceiling in previous step. Make sure the fan

is hanging straight. Rotate fan until the tab on the

Mounting bracket engages the slot on the Downrod

Ball. This must be done to prevent the fan body from

rotating when the blades are in motion.

For Canadian installation and for USA fan and light

kit combinations over 35 lbs, in both flush and

downrod modes the safety cable must be installed

into the house structure beams using 3” lag

screws, washers and lock washers provided. Make

sure that when the safety cable is fully extended

the lead wires are longer than the cable and no

stress is placed on the lead wires.

Note:If Installing The Secondary Support Safety

Cable in the U.S., Do Not Remove Knockouts In

The Outlet Box.

13

14

15

Make sure the studs protruding from the

bottom of the Mounting bracket are in-

stalled with threads all the way through

the bracket.

Make wiring connections as indicated

above. Connect black and blue wire from

fan to Black or (Hot) wire from house.

Connect White wire from Fan to White

(Neutral) wire from house. Connect

Ground leads from mounting bracket and

downrod to Ground lead from house.

Refer to Safety Tips section of manual.

Make wire connections to power source using wire nuts

provided. Make sure that no filiments are outside of

the wirenut. After making the wire connections, the

wires should be spread apart with the grounded con-

ductor and the equipment-grounding conductor on one

side of the outlet box and ungrounded conductor on the

other side of the outlet box.

16

17

Flush mount installation

Go to step 26

Cover

Ring

Lift Conopy allowing the 2 studs to

protrude through the canopy.

Next lift the cover ring and install knurled

nuts as shown. Tighten the knurled nuts

securely. The canopy should adjust for

any irregularity in the ceiling or Outlet

box.

Remove every other screw as circled

and save for later use.

Note: Flushmount is not available

with vaulted ceiling.

© 2013 Monte Carlo Fan Company

4

8/13/2013

18

19

20

“L” shape

slots

Install rubber pad between fan

body and canopy.

Remove side covers from canopy exposing

4 holes. 2 closed holes and 2 open “L”

shape holes and then Pass leadwires and

safety cable through the canopy.

Place canopy over fan body align-

ing holes.

Replace the 3 screws removed and

tighten securely. Check motor for

shipping stabilizers and remove if

present.

21

22

23

Hands free hook

Remove the all thread studs from the

lower part of the mounting bracket. Hang

fan from mounting bracket by the

hands free hook into a closed hole on

the edge of the : For

Canadian mounting refer to Step #12.

Take 4 screws from hardware pack

and install one on each side of

bracket to match the L slot screw

holes in canopy. Keep 2 screws for

later use.

Make wiring connections as indicated

above. Connect black and blue wire from

fan to Black or (Hot) wire from house.

Connect White wire from Fan to White

(Neutral) wire from house. Connect

Ground leads from mounting bracket and

downrod to Ground lead from house.

Refer to Safety Tips section of manual.

24

25

26

Make wire connections to power source using wire nuts

provided. Make sure that no filiments are outside of

the wirenut. After making the wire connections, the

wires should be spread apart with the grounded con-

ductor and the equipment-grounding conductor on one

side of the outlet box and ungrounded conductor on the

other side of the outlet box.

Lift fan to mounting bracket, aligning the “L”

shape holes with the screws on the mounting

bracket. Turn the fan clockwise to lock in

position. Install the other 2 screws included

in hardware bag and tighten all 4 securely.

Check the motor for shipping stabiliz-

ers and remove if present. Attach

blades using screws and washers in

hardware pack. Tighten screws se-

curely.

Note: Tighten set screws twice a

year.

© 2013 Monte Carlo Fan Company

5

8/13/2013

27

28

29

Loosen 2 screws and remove 1 screw

from motor plate. Save removed

screw for use later.

Install by twisting clockwise, add 1

screw removed step 27 to switch

housing plate. Tighten the 3 screws

securely.

Connect plug from fan to switch

house plug. Be sure plugs connection

snap together completely.

30

31

32

Loosen the pre installed screws of

switch housing plate. Save removed

screw for use later.

Connect white wire from fan to white

wire from light fixture. Then plug

blue wire from fan to black wire from

light fixture.

Install 3 screws to install light pan.

33

34

35

Install a JD 75 watt halogen bulb, bulb in-

cluded.

Caution: Do not replace bulb until it cools

down.

WARNING:Over lamping the fan will re-

sult in the fan lights shutting down until

the proper wattage of bulbs are installed.

Reset the lights by turning off the wall

switch, breaker,or by remote. Replace bulbs

with the correct wattage bulbs, turn the

power on.

Left hand side

(Forward)

Reverse switch

Right hand side

(Reverse)

Attach glass by locating dimples in

light fixture with the groves in glass

and twisting clockwise till tight.

Setting the reverse switch in the left hand

side will result in downward airflow and set-

ting the switch in the right hand side will re-

sult in upward airflow.

Note: Reverse switch must be set either

completely LEFT or completely Right for fan

to function. If the reverse switch is set in the

middle position, fan will not operate.

© 2013 Monte Carlo Fan Company

6

8/13/2013

T

ROUBLE

S

HOOTING

If you have difficulty operating your new ceiling fan, it may be the result of incorrect assembly, installation, or

wiring. In some cases, these installation errors may be mistaken for defects. If you experience any faults, please

check this Trouble Shooting Chart. If a problem cannot be remedied, or you are experiencing difficulty in installa-

tion, please call our Customer Service Center at the

number printed on your parts list insert sheet.

Warning: Before servicing or cleaning unit, Switch power off at Service panel and lock service discon-

necting means to prevent power from being switched on accidentally. When the service disconnecting

means cannot be locked, securely fasten a

prominent warning device, such as a tag, to the service panel.

Trouble

1. If fan does not start:

Suggested Remedy

main and branch circuit fuses or circuit breakers.

line wire connections to fan and switch wire connections in switch housing.

CAUTION: Make sure main power is turned off.

sure forward/reverse switch is firmly in up or down position. Fan will not operate

when switch is in the middle.

sure that shipping stabilizer tabs have been removed from motor.

to make sure all screws in motor housing are snug (not over tightened).

to make sure the screws which attach the fan blade holder to the motor are tight.

to make sure wire nut connectors in switch housing are not rattling against each

other or against the interior wall of the switch housing.

CAUTION: Make sure main power is turned off before entering switch housing.

using an optional Ceiling Fan Light Kit, check to be sure the screws securing the glass-

ware are finger tight. Check to be sure light bulb is tight in socket and not touching glass

shade(s). If vibration persists from glass, remove glass and install a 1/4" wide rubber band

on glass neck to act as an insulator. Replace glass and tighten screws against rubber band.

fan motors are sensitive to signals from Solid State variable speed controls. DO NOT

USE a Solid State variable speed control.

"break-in" period of 24 hours. Most noises associated with a new fan will disappear

after this period.

this is a downrod mount fan, make sure the ridge on mounting bracket engages the

notch in the downrod ball.

that all blades are screwed firmly into blade holders.

that all blade holders are tightened securely to motor.

sure that canopy and mounting bracket are tightened securely to ceiling junction box

and junction box is mounted firmly to ceiling joist.

fan wobble problems are caused when blade levels are unequal. Check this level by

selecting a point on the ceiling above the tip of one of the blades. Measure this distance from

blade tip to ceilng. Keeping measure within 1/8", rotate the fan until the next blade is posi-

tioned for measurement. Repeat for each blade. If all blade levels are not equal, you can ad-

just blade levels by the following procedure. To adjust a blade tip down, insert a washer (not

supplied) between the blade and blade holder at the screw closest to the motor. To adjust a

blade tip up, insert washer (not supplied) between the blade and blade holder at the two

screws farthest from the motor. Reverse the position of the washer if blades mount from top

of blade.

blade wobble is still noticeable, interchanging two adjacent (side by side) blades can re-

distribute the weight and possibly result in smoother operation.

blue wire from fan to make sure it is connected to hot wire from house.

for loose or disconnected wires in fan switch housing.

for loose or disconnected wires in light kit.

for faulty light bulbs.

WARNING:Over lamping the fan will result in the fan lights shutting down

until the proper wattage of bulbs are installed.

Reset the lights by turning off the wall switch, breaker,or by remote. Replace bulbs

with the correct wattage bulbs, turn the power on.

CAUTION: Make sure main power is turned off before entering switch housing.

2. If fan sounds noisy:

3. If fan wobbles:

4. If light does not work:

© 2013 Monte Carlo Fan Company

7

8/13/2013

Apr.2013

May.2013 CUL requirement

Aug.2013 dual mount

Jul.2014 logo on canopy

发布评论

评论列表 (0)

  1. 暂无评论