Magnum Energy ME-ARTR高级路由器数据手册说明书

IT圈 admin 25浏览 0评论

2024年10月16日发(作者:麦庆生)

ME-ARTR

|

ADVANCED ROUTER

Introduction

PROVIDES COMPLETE SYSTEM-LEVEL CONNECTIVITY AND PROGRAMMING

Quickly and easily connect multiple inverter/chargers, charge controllers, and accessories without individual programming using the ME-ARTR

Advanced Router. This router is designed to provide system-level connectivity and programming for large Magnum Energy installations. One

ME-ARTR can accommodate up to four MS-PAE or MS-PE inverter/chargers in parallel and program up to seven PT-100 solar charge controllers

at once. The advanced router can also work with two ME-AGS modules, multiple ME-BMK monitors, and one ME-ARC or ME-RC remote.

Features

• Harvest up to 42kW of solar with the ability to program and connect

to the balance of system equipment with one ME-ARTR.

• Install firmware upgrades in the field with a microSD card.

• “Bulk Always” setting always starts in BULK charging mode, ideal

for charging li-on chemistries with custom settings.

• Optimized scheduling parameters with pop-up reminders for better

feedback to ensure the system is perfoming at peak levels.

• No programming necessary for MS-PAE parallel operation.

Model Number

• ME-ARTR

Works With

• MMP Panel System

• MP Panel System

• MS-PAE Inverter/Charger

• MS-PE Inverter/Charger

• PT-100 Charge Controller

• ME-AGS Auto Gen Start

• ME-BMK Battery Monitor

• ME-ARC Remote

• ME-RC Remote

Page 1

Copyright © 2019 Sensata Technologies, Inc.

SPECIFICATIONS

INPUTS

Parallel stack ports

Aux relay

Comm/accessory ports

MicroSD card slot

POWER REQUIREMENTS

Power consumption (on)

BATTERY SETTINGS

Available battery settings

Available battery types

Communication default battery type

GENERAL FEATURES

Warranty

PHYSICAL SPECIFICATIONS

Dimension (WxHxD)

Ambient temperature range

8.94” x 6.63” x 1.94” (22.7 cm x 16.8 cm x 4 cm)

-4 °F to 149 °F (-20 °C to 65 °C)

One year. Five years if installed on a Magnum Energy MMP or MP System.

Bulk, Absorb, Float, EQ, Bulk Always

AGM1, AGM2, Flooded, GEL, CC/CV, Custom

Flooded

2.8 watts

Four Cat 5 ports

One 2-wire terminal

Six

One

AT-A-GLANCE DIAGRAM

The ME-ARTR is designed to allow cables to be

concealed behind the front cover or they may be

threaded through an opening in the wall.

Four-line LCD Display

Status LEDs

On/Off Buttons

PORT, CTRL, METER,

SETUP, TECH Buttons

S

E

L

E

C

T

Intuitive Rotary Select

Knob

Audible feedback for each motion

making the router easier to

navigate and program

Comm LEDs

GENERAL NOTES

Testing for specifications at 25°C.

Specifications subject to change without notice.

Page 2

Sensata Technologies, Inc. (“Sensata”) data sheets are solely intended to assist designers (“Buyers”) who are developing systems that

incorporate Sensata products (also referred to herein as “components”). Buyer understands and agrees that Buyer remains responsible

for using its independent analysis, evaluation and judgment in designing Buyer’s systems and products. Sensata data sheets have

been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that

specifically described in the published documentation for a particular data sheet. Sensata may make corrections, enhancements,

improvements and other changes to its data sheets or components without notice.

Buyers are authorized to use Sensata data sheets with the Sensata component(s) identified in each particular data sheet. HOWEVER, NO

OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND

NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATA SHEETS

ARE PROVIDED “AS IS”. SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATA SHEETS OR USE

OF THE DATA SHEETS, EXPRESS, IMPLIED OR STATUTORY, INCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS

ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, QUIET

ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD

TO SENSATA DATA SHEETS OR USE THEREOF.

All products are sold subject to Sensata’s terms and conditions of sale supplied at SENSATA ASSUMES NO LIABILITY

FOR APPLICATIONS ASSISTANCE OR THE DESIGN OF BUYERS’ PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY

RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY AND SAFETY-RELATED REQUIREMENTS CONCERNING ITS PRODUCTS,

AND ANY USE OF SENSATA COMPONENTS IN ITS APPLICATIONS, NOTWITHSTANDING ANY APPLICATIONS-RELATED INFORMATION

OR SUPPORT THAT MAY BE PROVIDED BY SENSATA.

Mailing Address: Sensata Technologies, Inc., 529 Pleasant Street, Attleboro, MA 02703, USA.

CONTACT US

651-653-7000

800-553-6418

************************

Power Conversion

Copyright © 2019 Sensata Technologies, Inc.

Rev: 07/20/19 Part#64-0676 vB

2024年10月16日发(作者:麦庆生)

ME-ARTR

|

ADVANCED ROUTER

Introduction

PROVIDES COMPLETE SYSTEM-LEVEL CONNECTIVITY AND PROGRAMMING

Quickly and easily connect multiple inverter/chargers, charge controllers, and accessories without individual programming using the ME-ARTR

Advanced Router. This router is designed to provide system-level connectivity and programming for large Magnum Energy installations. One

ME-ARTR can accommodate up to four MS-PAE or MS-PE inverter/chargers in parallel and program up to seven PT-100 solar charge controllers

at once. The advanced router can also work with two ME-AGS modules, multiple ME-BMK monitors, and one ME-ARC or ME-RC remote.

Features

• Harvest up to 42kW of solar with the ability to program and connect

to the balance of system equipment with one ME-ARTR.

• Install firmware upgrades in the field with a microSD card.

• “Bulk Always” setting always starts in BULK charging mode, ideal

for charging li-on chemistries with custom settings.

• Optimized scheduling parameters with pop-up reminders for better

feedback to ensure the system is perfoming at peak levels.

• No programming necessary for MS-PAE parallel operation.

Model Number

• ME-ARTR

Works With

• MMP Panel System

• MP Panel System

• MS-PAE Inverter/Charger

• MS-PE Inverter/Charger

• PT-100 Charge Controller

• ME-AGS Auto Gen Start

• ME-BMK Battery Monitor

• ME-ARC Remote

• ME-RC Remote

Page 1

Copyright © 2019 Sensata Technologies, Inc.

SPECIFICATIONS

INPUTS

Parallel stack ports

Aux relay

Comm/accessory ports

MicroSD card slot

POWER REQUIREMENTS

Power consumption (on)

BATTERY SETTINGS

Available battery settings

Available battery types

Communication default battery type

GENERAL FEATURES

Warranty

PHYSICAL SPECIFICATIONS

Dimension (WxHxD)

Ambient temperature range

8.94” x 6.63” x 1.94” (22.7 cm x 16.8 cm x 4 cm)

-4 °F to 149 °F (-20 °C to 65 °C)

One year. Five years if installed on a Magnum Energy MMP or MP System.

Bulk, Absorb, Float, EQ, Bulk Always

AGM1, AGM2, Flooded, GEL, CC/CV, Custom

Flooded

2.8 watts

Four Cat 5 ports

One 2-wire terminal

Six

One

AT-A-GLANCE DIAGRAM

The ME-ARTR is designed to allow cables to be

concealed behind the front cover or they may be

threaded through an opening in the wall.

Four-line LCD Display

Status LEDs

On/Off Buttons

PORT, CTRL, METER,

SETUP, TECH Buttons

S

E

L

E

C

T

Intuitive Rotary Select

Knob

Audible feedback for each motion

making the router easier to

navigate and program

Comm LEDs

GENERAL NOTES

Testing for specifications at 25°C.

Specifications subject to change without notice.

Page 2

Sensata Technologies, Inc. (“Sensata”) data sheets are solely intended to assist designers (“Buyers”) who are developing systems that

incorporate Sensata products (also referred to herein as “components”). Buyer understands and agrees that Buyer remains responsible

for using its independent analysis, evaluation and judgment in designing Buyer’s systems and products. Sensata data sheets have

been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that

specifically described in the published documentation for a particular data sheet. Sensata may make corrections, enhancements,

improvements and other changes to its data sheets or components without notice.

Buyers are authorized to use Sensata data sheets with the Sensata component(s) identified in each particular data sheet. HOWEVER, NO

OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND

NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATA SHEETS

ARE PROVIDED “AS IS”. SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATA SHEETS OR USE

OF THE DATA SHEETS, EXPRESS, IMPLIED OR STATUTORY, INCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS

ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, QUIET

ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD

TO SENSATA DATA SHEETS OR USE THEREOF.

All products are sold subject to Sensata’s terms and conditions of sale supplied at SENSATA ASSUMES NO LIABILITY

FOR APPLICATIONS ASSISTANCE OR THE DESIGN OF BUYERS’ PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY

RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY AND SAFETY-RELATED REQUIREMENTS CONCERNING ITS PRODUCTS,

AND ANY USE OF SENSATA COMPONENTS IN ITS APPLICATIONS, NOTWITHSTANDING ANY APPLICATIONS-RELATED INFORMATION

OR SUPPORT THAT MAY BE PROVIDED BY SENSATA.

Mailing Address: Sensata Technologies, Inc., 529 Pleasant Street, Attleboro, MA 02703, USA.

CONTACT US

651-653-7000

800-553-6418

************************

Power Conversion

Copyright © 2019 Sensata Technologies, Inc.

Rev: 07/20/19 Part#64-0676 vB

发布评论

评论列表 (0)

  1. 暂无评论