INSTALLATION MANUAL

EKRTWA

1

m

h

.

2

c

0

i

n

>

8

>

2

60 mm/2.36 inch

34 mm/1.34 inch

8

7

m

m

/

3

.

4

3

i

n

c

h

±

1

.

5

m

±

6

0

i

n

c

h

125 mm/4.92 inch

3

EKRTWA

Room thermostatInstallation manual

Read this manual attentively before starting up the unit.

Do not throw it away. Keep it in your files for future

reference.

The English text is the original instruction. Other languages are

translations of the original instructions.

Improper installation or attachment of equipment or

accessories could result in electric shock, short-circuit,

leaks, fire or other damage to the equipment. Be sure

only to use accessories made by Daikin which are

specifically designed for the use with the equipment and

have them installed by a professional.

If unsure of installation procedures or use, always

contact your dealer for advice and information.

Contents

1. 1

2. Installation of 2

3. Setting up codes in the 5

4. 11

uction

The room thermostat EKRTWA can be used to control the Daikin

system (radiator heating and floor heating/cooling applications).

It is typically connected to the Daikin unit. Refer to the "Typical

application examples" in the Installation manual of the Daikin

unit.

■In case of floor heating-only applications the room

thermostat can also be connected to the individual motorized

valve of the floor heating loop.

EKRTWA

Room thermostat

4PW56101-1

Installation manual

1

■If a floor heating-only application is used in combination with

fan coil units each fan coil unit should have its dedicated fan

coil thermostat.

lation of the EKRTWA

The EKRTWA thermostat is wall-mounted, with supplied screws

and plugs. Refer to figure 1.

Cabling towards the Daikin system (field supply) should be

foreseen in advance taking the suggestions for an ideal

installation location into account. Refer to figure 2.

Before obtaining access to terminals, all power

supply circuits must be interrupted.

1

2

3

At the left of the thermostat, gently push the lid.

Remove the front cover by pulling it towards you.

Unscrew the screw of the cable holder in the bottom left

corner of the back part of the thermostat and remove the

transparent cable protection.

Remove the battery insulator.4

4

1

3

2

3

5Drill holes in the wall taking the dimensions of the thermostat

into account and insert the supplied plugs in the holes.

Refer to figure 3.

Installation manual

2

EKRTWA

Room thermostat

4PW56101-1

6Pass the unit or motorized valve wiring through the back of

the thermostat.

7According your application, perform the wiring.

All field wiring and components must be installed by

a licensed electrician and must comply with relevant

European and national regulations.

7aWhen connected to the unit, refer to the wiring diagram of

the unit.

Example unit

HCLN

X1M

C

com

H

H

C

Heating demand

Cooling demand

For heating-only applications, wire connection to C is not to

be installed.

Use wire size 0.75~1.50 mm

2

/AWG18~16.

EKRTWA

Room thermostat

4PW56101-1

Installation manual

3

7bWhen connected to the motorized valve, wire the motorized

valve and the thermostat as shown below (for heating-only

applications).

Power supply

X1M

C

com

H

The output relays (H and C) are voltage-free contacts. Refer

to "Technical characteristics" on page 11 for maximum load.

8Fasten the thermostat with the supplied screws.

Be careful not to pinch the wiring when fastening.

9Put the transparent cable protection back into place and fix

the cable protection with the screw.

10Close the thermostat cover.

11Remove the protective film from the LCD.

Installation manual

4

EKRTWA

Room thermostat

4PW56101-1

g up codes in the installer menu

You can set up codes, starting from the time and date menu (in

advanced mode).

NOTE

As a consequence of a customized configuration, it

is not abnormal that some codes are no longer

accessible.

1

2

3

Activate the advanced mode by pressing

>

during 5

seconds in OFF mode (

D

).

Navigate to the date and clock setting menu (

G

) by pressing

>

.

Press

>

and keep it pressed while now pressing

=

during 10 seconds.

y

is displayed next to

.

4

5

6

Press

<

or

>

to consult the current settings of the

codes.

To modify codes, press

+

,

-

or

=

.

The value is flashing when being modified.

Press

+

or

-

to increase or decrease the code value by

1 step.

To put a code back to its default value, press

+

and

-

at

the same time.

Press

=

to save your selection.

You can exit this code menu by going to the "

/

" code and

pressing

=

.

7

EKRTWA

Room thermostat

4PW56101-1

Installation manual

5

-up for Fahrenheit degree type

Refer to the operation manual how to change parameter in user

menu.

1st

code

2nd

codeDescription

Degrees type.

Range

°C/°F

3.2.

1st

code

01

Set-up for heating/cooling applications

2nd

code

Required

setting

For heating/cooling applications, set the following codes:

Description

Cooling mode present?

3.3.

01

ÚêÒ

Set-up for radiator applications

Before operation, change the following temperature control

parameter to the required setting for radiator applications.

1st

code

2nd

codeDescription

Required

setting

6®02

Use proportional band control?

?

(=hysteresis)

Installation manual

6

EKRTWA

Room thermostat

4PW56101-1

ew of all codes

Following codes can be changed in the installer menu:

1st 2nd

codecodeDescriptionDefaultRangeStep

0.1°C

0.2°F

Readout codes

4®01

+

R

Calibration of

internal sensor.

Actual

temperature +

offset are

displayed. The

h

symbol

appears when

the offset

deviates from 0.

Offset = 0Offset:

–5°C~5°C

Offset:

–9°F~9°F

Installation codes

5®01

Cooling mode

present?

≈œÚêÒ

/

≈œ

Temperature control codes

Daikin advizes not to change below temperature control

parameters. They are set for an optimal use of the Daikin

system.

6®02

Use

proportional

band control?

Hysteresis

value

proportional

band (heating).

ÚêÒÚêÒ

(proportional

band)/

≈œ

(hysteresis)

0300.5

00.9

020

009

00.5

~

02.0

00.9

~

03.6

010

~

060

002

~

6® 04

/2

0.1°C

0.1°F

1 min.

04

+

p

Duration

05

+

p

Minimum "on"

time (heat

demand).

1 min.

EKRTWA

Room thermostat

4PW56101-1

Installation manual

7

1st 2nd

codecodeDescription

between 2

heating cycles.

DefaultRangeStep

1 min.

6®06

+

p

Minimum delay

005

07

+

o

Duration

proportional

band (cooling).

001

~

6® 04

/2

010

~

060

002

~

6® 07

/2

001

~

6® 07

/2

01.0

~

04.0

01.8

~

07.2

020

007

1 min.

08

+

o

Minimum "on"

time (cool

demand).

1 min.

09

+

o

Minimum delay

003

between 2

cooling cycles.

1 min.

10

11

12

13

Value of

proportional

band.

Not used

parameter

02.0

03.6

0.1°C

0.1°F

0.5°C

0.5°F

0.5°C

0.5°F

Upper setpoint

37.0

limitation.

99.0

Lower setpoint

04.0

limitation.

39.5

22.0

~

37.0

72.0

~

99.0

04.0

~

20.0

39.0

~

68.0

Installation manual

8

EKRTWA

Room thermostat

4PW56101-1

1st 2nd

codecodeDescriptionDefaultRangeStep

Schedule timer codes

8®01

Enable cooling/

≈œ

heating link for

the user-

defined

schedules

◊1

and

◊2

?

When enabled

and a user-

defined

schedule is

selected in the

schedule timer

setting menu:

in heating

mode, schedule

◊1

will be active;

in cooling

mode, schedule

◊2

will be active.

ÚêÒ

/

≈œ

EKRTWA

Room thermostat

4PW56101-1

Installation manual

9

1st 2nd

codecodeDescriptionDefaultRangeStep

Miscellaneous codes

9®01

Daylight saving

ÚêÒ

time

implementation.

(installation

check).

ÚêÒ

/

≈œ

ÚêÒ

/

≈œ

ÚêÒ

/

≈œ

02 + p

Forced heating

≈œ

03 + o

Forced cooling

≈œ

(installation

check).

15 +

Reset all

settings back to

®êÒê‹æ¬¬

factory

configuration.

Press

=

during 5

seconds. The

complete LCD

is shown to

confirm all

settings are

reset.

After resetting all settings back to factory

configuration (

15

+

®êÒê‹æ¬¬

), the parameters must be

changed manually again.

Installation manual

10

EKRTWA

Room thermostat

4PW56101-1

cal characteristics

Temperature read out

Operating temperature

Setpoint temperature

range

Electrical protection

Steps of 0.1°C/0.1°F

0°C~50°C/32°F~122°F

4°C~37°C in steps of 0.5°C/

39.5°F~99°F in steps of 0.5°F

Class II - IP30 (indoor use, polution

degree 2)

Feeding and autonomy3 alkaline batteries 6 1.5 V

approximately 2 years (depending on

usage conditions)

Output relaysFor United States of America and

Canada:

Maximum load 1 A - 24 VAC

For other countries:

Maximum load 5 A - 230 VAC

Immunity against voltage Category III (2.5 kV)

surges

Type of automatic action 1C

of the thermostat

EKRTWA

Room thermostat

4PW56101-1

Installation manual

11

n

i

k

i

a

D

©

t

h

g

i

r

y

p

o

C

4PW56101-1

2024年10月18日发(作者:锺希)

INSTALLATION MANUAL

EKRTWA

1

m

h

.

2

c

0

i

n

>

8

>

2

60 mm/2.36 inch

34 mm/1.34 inch

8

7

m

m

/

3

.

4

3

i

n

c

h

±

1

.

5

m

±

6

0

i

n

c

h

125 mm/4.92 inch

3

EKRTWA

Room thermostatInstallation manual

Read this manual attentively before starting up the unit.

Do not throw it away. Keep it in your files for future

reference.

The English text is the original instruction. Other languages are

translations of the original instructions.

Improper installation or attachment of equipment or

accessories could result in electric shock, short-circuit,

leaks, fire or other damage to the equipment. Be sure

only to use accessories made by Daikin which are

specifically designed for the use with the equipment and

have them installed by a professional.

If unsure of installation procedures or use, always

contact your dealer for advice and information.

Contents

1. 1

2. Installation of 2

3. Setting up codes in the 5

4. 11

uction

The room thermostat EKRTWA can be used to control the Daikin

system (radiator heating and floor heating/cooling applications).

It is typically connected to the Daikin unit. Refer to the "Typical

application examples" in the Installation manual of the Daikin

unit.

■In case of floor heating-only applications the room

thermostat can also be connected to the individual motorized

valve of the floor heating loop.

EKRTWA

Room thermostat

4PW56101-1

Installation manual

1

■If a floor heating-only application is used in combination with

fan coil units each fan coil unit should have its dedicated fan

coil thermostat.

lation of the EKRTWA

The EKRTWA thermostat is wall-mounted, with supplied screws

and plugs. Refer to figure 1.

Cabling towards the Daikin system (field supply) should be

foreseen in advance taking the suggestions for an ideal

installation location into account. Refer to figure 2.

Before obtaining access to terminals, all power

supply circuits must be interrupted.

1

2

3

At the left of the thermostat, gently push the lid.

Remove the front cover by pulling it towards you.

Unscrew the screw of the cable holder in the bottom left

corner of the back part of the thermostat and remove the

transparent cable protection.

Remove the battery insulator.4

4

1

3

2

3

5Drill holes in the wall taking the dimensions of the thermostat

into account and insert the supplied plugs in the holes.

Refer to figure 3.

Installation manual

2

EKRTWA

Room thermostat

4PW56101-1

6Pass the unit or motorized valve wiring through the back of

the thermostat.

7According your application, perform the wiring.

All field wiring and components must be installed by

a licensed electrician and must comply with relevant

European and national regulations.

7aWhen connected to the unit, refer to the wiring diagram of

the unit.

Example unit

HCLN

X1M

C

com

H

H

C

Heating demand

Cooling demand

For heating-only applications, wire connection to C is not to

be installed.

Use wire size 0.75~1.50 mm

2

/AWG18~16.

EKRTWA

Room thermostat

4PW56101-1

Installation manual

3

7bWhen connected to the motorized valve, wire the motorized

valve and the thermostat as shown below (for heating-only

applications).

Power supply

X1M

C

com

H

The output relays (H and C) are voltage-free contacts. Refer

to "Technical characteristics" on page 11 for maximum load.

8Fasten the thermostat with the supplied screws.

Be careful not to pinch the wiring when fastening.

9Put the transparent cable protection back into place and fix

the cable protection with the screw.

10Close the thermostat cover.

11Remove the protective film from the LCD.

Installation manual

4

EKRTWA

Room thermostat

4PW56101-1

g up codes in the installer menu

You can set up codes, starting from the time and date menu (in

advanced mode).

NOTE

As a consequence of a customized configuration, it

is not abnormal that some codes are no longer

accessible.

1

2

3

Activate the advanced mode by pressing

>

during 5

seconds in OFF mode (

D

).

Navigate to the date and clock setting menu (

G

) by pressing

>

.

Press

>

and keep it pressed while now pressing

=

during 10 seconds.

y

is displayed next to

.

4

5

6

Press

<

or

>

to consult the current settings of the

codes.

To modify codes, press

+

,

-

or

=

.

The value is flashing when being modified.

Press

+

or

-

to increase or decrease the code value by

1 step.

To put a code back to its default value, press

+

and

-

at

the same time.

Press

=

to save your selection.

You can exit this code menu by going to the "

/

" code and

pressing

=

.

7

EKRTWA

Room thermostat

4PW56101-1

Installation manual

5

-up for Fahrenheit degree type

Refer to the operation manual how to change parameter in user

menu.

1st

code

2nd

codeDescription

Degrees type.

Range

°C/°F

3.2.

1st

code

01

Set-up for heating/cooling applications

2nd

code

Required

setting

For heating/cooling applications, set the following codes:

Description

Cooling mode present?

3.3.

01

ÚêÒ

Set-up for radiator applications

Before operation, change the following temperature control

parameter to the required setting for radiator applications.

1st

code

2nd

codeDescription

Required

setting

6®02

Use proportional band control?

?

(=hysteresis)

Installation manual

6

EKRTWA

Room thermostat

4PW56101-1

ew of all codes

Following codes can be changed in the installer menu:

1st 2nd

codecodeDescriptionDefaultRangeStep

0.1°C

0.2°F

Readout codes

4®01

+

R

Calibration of

internal sensor.

Actual

temperature +

offset are

displayed. The

h

symbol

appears when

the offset

deviates from 0.

Offset = 0Offset:

–5°C~5°C

Offset:

–9°F~9°F

Installation codes

5®01

Cooling mode

present?

≈œÚêÒ

/

≈œ

Temperature control codes

Daikin advizes not to change below temperature control

parameters. They are set for an optimal use of the Daikin

system.

6®02

Use

proportional

band control?

Hysteresis

value

proportional

band (heating).

ÚêÒÚêÒ

(proportional

band)/

≈œ

(hysteresis)

0300.5

00.9

020

009

00.5

~

02.0

00.9

~

03.6

010

~

060

002

~

6® 04

/2

0.1°C

0.1°F

1 min.

04

+

p

Duration

05

+

p

Minimum "on"

time (heat

demand).

1 min.

EKRTWA

Room thermostat

4PW56101-1

Installation manual

7

1st 2nd

codecodeDescription

between 2

heating cycles.

DefaultRangeStep

1 min.

6®06

+

p

Minimum delay

005

07

+

o

Duration

proportional

band (cooling).

001

~

6® 04

/2

010

~

060

002

~

6® 07

/2

001

~

6® 07

/2

01.0

~

04.0

01.8

~

07.2

020

007

1 min.

08

+

o

Minimum "on"

time (cool

demand).

1 min.

09

+

o

Minimum delay

003

between 2

cooling cycles.

1 min.

10

11

12

13

Value of

proportional

band.

Not used

parameter

02.0

03.6

0.1°C

0.1°F

0.5°C

0.5°F

0.5°C

0.5°F

Upper setpoint

37.0

limitation.

99.0

Lower setpoint

04.0

limitation.

39.5

22.0

~

37.0

72.0

~

99.0

04.0

~

20.0

39.0

~

68.0

Installation manual

8

EKRTWA

Room thermostat

4PW56101-1

1st 2nd

codecodeDescriptionDefaultRangeStep

Schedule timer codes

8®01

Enable cooling/

≈œ

heating link for

the user-

defined

schedules

◊1

and

◊2

?

When enabled

and a user-

defined

schedule is

selected in the

schedule timer

setting menu:

in heating

mode, schedule

◊1

will be active;

in cooling

mode, schedule

◊2

will be active.

ÚêÒ

/

≈œ

EKRTWA

Room thermostat

4PW56101-1

Installation manual

9

1st 2nd

codecodeDescriptionDefaultRangeStep

Miscellaneous codes

9®01

Daylight saving

ÚêÒ

time

implementation.

(installation

check).

ÚêÒ

/

≈œ

ÚêÒ

/

≈œ

ÚêÒ

/

≈œ

02 + p

Forced heating

≈œ

03 + o

Forced cooling

≈œ

(installation

check).

15 +

Reset all

settings back to

®êÒê‹æ¬¬

factory

configuration.

Press

=

during 5

seconds. The

complete LCD

is shown to

confirm all

settings are

reset.

After resetting all settings back to factory

configuration (

15

+

®êÒê‹æ¬¬

), the parameters must be

changed manually again.

Installation manual

10

EKRTWA

Room thermostat

4PW56101-1

cal characteristics

Temperature read out

Operating temperature

Setpoint temperature

range

Electrical protection

Steps of 0.1°C/0.1°F

0°C~50°C/32°F~122°F

4°C~37°C in steps of 0.5°C/

39.5°F~99°F in steps of 0.5°F

Class II - IP30 (indoor use, polution

degree 2)

Feeding and autonomy3 alkaline batteries 6 1.5 V

approximately 2 years (depending on

usage conditions)

Output relaysFor United States of America and

Canada:

Maximum load 1 A - 24 VAC

For other countries:

Maximum load 5 A - 230 VAC

Immunity against voltage Category III (2.5 kV)

surges

Type of automatic action 1C

of the thermostat

EKRTWA

Room thermostat

4PW56101-1

Installation manual