2024年10月27日发(作者:史迎梅)
PT-G7728Series
IEC61850-328-portLayer2fullGigabitmodularmanagedEthernetswitches
FeaturesandBenefits
•
IEC61850-3Edition2Class2compliantforEMC
•
Wideoperatingtemperaturerange:-40to85°C(-40to185°F)
•
Hot-swappableinterfaceandpowermodulesforcontinuousoperation
•
IEEE1588hardwaretimestampsupported
•
SupportsIEEEC37.238andIEC61850-9-4powerprofiles
•
IEC62439-3Clause4(PRP)andClause5(HSR)compliant
•
GOOSECheckforeasytroubleshooting
•
Built-inMMSserverbasedonIEC61850-90-4switchdatamodelingfor
powerSCADA
Certifications
Introduction
ThePT-G7728Seriesmodularswitchesprovideupto28Gigabitports,including4fixedports,6interfacemoduleslots,and2powermoduleslots
-G7728Seriesisdesignedtomeetevolvingnetworkrequirements,featuringahot-
swappablemoduledesignthatenablesyoutochange,add,orremovemoduleswithouthavingtoshutdowntheswitch.
Multipletypesofinterfacemodules(RJ45,SFP,PoE,PRP/HSR)andpowerunits(24/48VDC,110/220VAC/VDC)provideevengreaterflexibilityto
-G7728SeriescomplieswiththeIEC61850-3Edition2Class2standardtoensurereliabledata
transmissionswhenthedeviceissubjectedtohighlevelsofEMI,shock,orvibration.
Specifications
EthernetInterface
10/100/1000BaseT(X)Ports(RJ45connector)
100/1000BaseSFPPorts
Module
SlotCombination
2
2
6
SeetheLM-7000HdatasheetforinformationabouttheEthernet,PoE+,andPRP/HSR
modules.
IEEE802.3for10BaseT
IEEE802.3ufor100BaseT(X)and100BaseFX
IEEE802.3abfor1000BaseT(X)
IEEE802.3zfor1000BaseX
IEEE802.1D-2004forSpanningTreeProtocol
IEEE802.1wforRapidSpanningTreeProtocol
IEEE802.1pforClassofService
IEEE802.1QforVLANTagging
IEEE802.1Xforauthentication
IEEE802.3adforPortTrunkwithLACP
IEEE802.3xforflowcontrol
Standards
1
EthernetSoftwareFeatures
ManagementIPv4/IPv6
SNMPInform
SNMPv1/v2c/v3
DHCPServer/Client
DHCPOption66/67/82
BOOTP
TFTP
LLDP
RARP
HTTP
HTTPS
Telnet
Flowcontrol
BackPressureFlowControl
PortMirror
Fibercheck
DyingGasp
SMTP
Syslog
MIB-II
Ethernet-likeMIB
BridgeMIB
P-BRIDGEMIB
Q-BRIDGEMIB
RSTPMIB
RMONMIBGroups1,2,3,9
IGMPv1/v2/v3
GMRP
GVRP
802.1Q
QinQVLAN
LinkAggregation
MSTP
RSTP
STP
TurboChain
TurboRingv1/v2
V-ON
MRP
RADIUS
TACACS+
SSH
PortLock
Broadcaststormprotection
MABauthentication
StickyMAC
Accesscontrollist
NTPServer/Client
SNTP
IEEE1588v2PTP(hardware-based)
IEC61850QoS
GOOSECheck
EtherNet/IP
ModbusTCP
MIB
Filter
RedundancyProtocols
Security
TimeManagement
PowerSubstation
IndustrialProtocols
SwitchProperties
PriorityQueues
s
VLANIDRange
IGMPGroups
8
256
1to4094
4096
2
MACTableSize
PacketBufferSize
JumboFrameSize
16K
12Mbits
9.6KB
SerialInterface
ConsolePortRS-232(RJ45)
USBInterface
StoragePortUSBTypeA
PowerParameters
InputVoltageWithPWR-HV-P48installed:
110/220VDC/VACfortheswitchsystem
48VDCforPoEsystem(53to57VDCisrecommendedforPoE+devices)
WithPWR-LV-P48installed:
24/48VDCfortheswitchsystem
48VDCforPoEsystem(53to57VDCisrecommendedforPoE+devices)
WithPWR-HV-NPinstalled:
110/220VDC/VACfortheswitchsystem
WithPWR-LV-NPinstalled:
24/48VDCfortheswitchsystem
OperatingVoltageWithPWR-HV-P48installed:
88to300VDC,90to264VACfortheswitchsystem
46to57VDCforPoEsystems
WithPWR-LV-P48installed:
18to72VDCfortheswitchsystem
46to57VDCforPoEsystems
WithPWR-HV-NPinstalled:
88to300VDC,90to264VACfortheswitchsystem
WithPWR-LV-NPinstalled:
18to72VDCfortheswitchsystem
InputCurrentWithPWR-HV-P48installed:
PWRinputcurrent(switchsystem)
Max.0.11A@110VDC
Max.0.06A@220VDC
Max.0.29A@110VAC
Max.0.18A@220VAC
EPSinputcurrent(PoEsystem)
Max.0.53A@48VDC
(excludingpowerconsumptionofPoEdevices)
WithPWR-LV-P48installed:
PWRinputcurrent(switchsystem)
Max.0.53A@24VDC
Max.0.28A@48VDC
EPSinputcurrent(PoEsystem)
Max.0.53A@48VDC
(excludingpowerconsumptionofPoEdevices)
WithPWR-HV-NPinstalled:
PWRinputcurrent(switchsystem)
Max.0.11A@110VDC
Max.0.06A@220VDC
Max.0.29A@110VAC
Max.0.18A@220VAC
WithPWR-LV-NPinstalled:
PWRinputcurrent(switchsystem)
Max.0.53A@24VDC
Max.0.28A@48VDC
3
PhysicalCharacteristics
IPRating
Dimensions
Weight
Installation
IP30
443x44x280mm(17.44x1.73x11.02in)
3080g(6.8lb)
19-inchrackmounting
EnvironmentalLimits
OperatingTemperature
StorageTemperature(packageincluded)
AmbientRelativeHumidity
-40to85°C(-40to185°F)
-40to85°C(-40to185°F)
5to95%(non-condensing)
StandardsandCertifications
EMC
EMI
EMS
EN55032/35
CISPR32,FCCPart15BClassA
IEC61000-4-2ESD:Contact:8kV;Air:15kV
IEC61000-4-3RS:80MHzto1GHz:20V/m
IEC61000-4-4EFT:Power:4kV;Signal:4kV
IEC61000-4-5Surge:Power:4kV;Signal:4kV
IEC61000-4-6CS:10V
IEC61000-4-8PFMF
IEC61850-3Edition2Class2(EMC)
IEEE1613
EN50121-4
IEC62368-1
UL62368-1
PowerSubstation
Railway
Safety
MTBF
Time
Standards
449,542hrs
Telcordia(Bellcore),GB
Warranty
WarrantyPeriod
Details
5years
/warranty
PackageContents
Device
Cable
InstallationKit
1xPT-G7728Seriesswitch
USBcable(TypeAmaletoMicroUSBtypeB)
2xcap,forMicro-BUSBport
1xcap,metal,forABC-02USBstorageport
2xrack-mountingear
2xcap,plastic,forSFPslot
1xquickinstallationguide
1xwarrantycard
1xsubstancedisclosuretable
1xproductcertificatesofqualityinspection,SimplifiedChinese
1xproductnotice,SimplifiedChinese
SFPmodules,modulesfromtheLM-7000HModuleSeries,and/ormodulesfromthe
PWRPowerModuleSeriesneedtobepurchasedseparatelyforusewiththisproduct.
Documentation
Note
4
Dimensions
OrderingInformation
ModelNameLayer
100/1000BaseSFP
Slots
2to26
10/100/1000BaseT(X)
Ports
RJ45Connector
2to26
PoEPorts,10/100/
1000BaseT(X)
RJ45Connector
0to24
OperatingTemp.
PT-G77282-40to85°C
Accessories(soldseparately)
StorageKits
ABC-02-USB
ABC-02-USB-T
Configurationbackupandrestorationtool,firmwareupgrade,andlogfilestoragetoolformanaged
Ethernetswitchesandrouters,0to60°Coperatingtemperature
Configurationbackupandrestorationtool,firmwareupgrade,andlogfilestoragetoolformanaged
Ethernetswitchesandrouters,-40to75°Coperatingtemperature
PowerSupplies
PWR-HV-P48
PWR-LV-P48
PWR-HV-NP
PWR-LV-NP
Powersupplymodule(110/220VAC/VDC)withsystempowerinput,relay,PoEpowerinput
Powersupplymodule(24/48VDC)withsystempowerinput,relay,PoEpowerinput
Powersupplymodule(110/220VAC/VDC)withsystempowerinput,relay
Powersupplymodule(24/48VDC)withsystempowerinput,relay
LM-7000HModuleSeries
LM-7000H-4GTX
LM-7000H-4GSFP
LM-7000H-4GPoE
LM-7000H-4TX
LM-7000H-4PoE
LM-7000H-2GPHR
GigabitEthernetmodulewith410/100/1000BaseT(X)ports
GigabitEthernetmodulewith4100/1000BaseSFPslots
GigabitEthernetmodulewith410/100/1000BaseT(X)IEEE802.3af/atPoE+ports
FastEthernetmodulewith410/100BaseT(X)ports
FastEthernetmodulewith410/100BaseT(X)IEEE802.3af/atPoE+ports
GigabitEthernetmodulewith2100/1000BaseT(X)PRP/HSRor100/1000BaseSFPPRP/HSRcombo
ports,-40to75°Coperatingtemperature
SFPModules
5
SFP-1FELLC-T
SFP-1FEMLC-T
SFP-1FESLC-T
SFP-1GEZXLC
SFP-1G10ALC
SFP-1G10ALC-T
SFP-1G10BLC
SFP-1G10BLC-T
SFP-1G20ALC
SFP-1G20ALC-T
SFP-1G20BLC
SFP-1G20BLC-T
SFP-1G40ALC
SFP-1G40ALC-T
SFP-1G40BLC
SFP-1G40BLC-T
SFP-1GEZXLC-120
SFP-1GLHLC
SFP-1GLHLC-T
SFP-1GLHXLC
SFP-1GLHXLC-T
SFP-1GLSXLC
SFP-1GLSXLC-T
SFP-1GLXLC
SFP-1GLXLC-T
SFP-1GSXLC
SFP-1GSXLC-T
SFP-1GZXLC
SFPmodulewith1100Basesingle-modewithLCconnectorfor80kmtransmission,-40to85°C
operatingtemperature
SFPmodulewith1100Basemulti-mode,LCconnectorfor2/4kmtransmission,-40to85°Coperating
temperature
SFPmodulewith1100Basesingle-modewithLCconnectorfor40kmtransmission,-40to85°C
operatingtemperature
SFPmodulewith11000BaseEZXportwithLCconnectorfor110kmtransmission,0to60°Coperating
temperature
WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor10kmtransmission;TX
1310nm,RX1550nm,0to60°Coperatingtemperature
WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor10kmtransmission;TX
1310nm,RX1550nm,-40to85°Coperatingtemperature
WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor10kmtransmission;TX
1550nm,RX1310nm,0to60°Coperatingtemperature
WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor10kmtransmission;TX
1550nm,RX1310nm,-40to85°Coperatingtemperature
WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor20kmtransmission;TX
1310nm,RX1550nm,0to60°Coperatingtemperature
WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor20kmtransmission;TX
1310nm,RX1550nm,-40to85°Coperatingtemperature
WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor20kmtransmission;TX
1550nm,RX1310nm,0to60°Coperatingtemperature
WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor20kmtransmission;TX
1550nm,RX1310nm,-40to85°Coperatingtemperature
WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor40kmtransmission;TX
1310nm,RX1550nm,0to60°Coperatingtemperature
WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor40kmtransmission;TX
1310nm,RX1550nm,-40to85°Coperatingtemperature
WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor40kmtransmission;TX
1550nm,RX1310nm,0to60°Coperatingtemperature
WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor40kmtransmission;TX
1550nm,RX1310nm,-40to85°Coperatingtemperature
SFPmodulewith11000BaseEZXportwithLCconnectorfor120kmtransmission,0to60°Coperating
temperature
SFPmodulewith11000BaseLHportwithLCconnectorfor30kmtransmission,0to60°Coperating
temperature
SFPmodulewith11000BaseLHportwithLCconnectorfor30kmtransmission,-40to85°Coperating
temperature
SFPmodulewith11000BaseLHXportwithLCconnectorfor40kmtransmission,0to60°Coperating
temperature
SFPmodulewith11000BaseLHXportwithLCconnectorfor40kmtransmission,-40to85°C
operatingtemperature
SFPmodulewith11000BaseLSXportwithLCconnectorfor1km/2kmtransmission,0to60°C
operatingtemperature
SFPmodulewith11000BaseLSXportwithLCconnectorfor1km/2kmtransmission,-40to85°C
operatingtemperature
SFPmodulewith11000BaseLXportwithLCconnectorfor10kmtransmission,0to60°Coperating
temperature
SFPmodulewith11000BaseLXportwithLCconnectorfor10kmtransmission,-40to85°Coperating
temperature
SFPmodulewith11000BaseSXportwithLCconnectorfor300m/550mtransmission,0to60°C
operatingtemperature
SFPmodulewith11000BaseSXportwithLCconnectorfor300m/550mtransmission,-40to85°C
operatingtemperature
SFPmodulewith11000BaseZXportwithLCconnectorfor80kmtransmission,0to60°Coperating
temperature
6
SFP-1GZXLC-TSFPmodulewith11000BaseZXportwithLCconnectorfor80kmtransmission,-40to85°Coperating
temperature
Software
MXview-50
MXview-100
MXview-250
MXview-500
MXview-1000
MXview-2000
MXviewUpgrade-50
MXviewlicensefor50nodes
MXviewlicensefor100nodes
MXviewlicensefor250nodes
MXviewlicensefor500nodes
MXviewlicensefor1000nodes
MXviewlicensefor2000nodes
MXviewlicenseexpansionfor50nodes
©dAug28,2023.
Thisdocumentandanyportionthereofmaynotbereproducedorusedinanymannerwhatsoeverwithouttheexpresswrittenpermissionof
urwebsiteforthemostup-to-dateproductinformation.
7
2024年10月27日发(作者:史迎梅)
PT-G7728Series
IEC61850-328-portLayer2fullGigabitmodularmanagedEthernetswitches
FeaturesandBenefits
•
IEC61850-3Edition2Class2compliantforEMC
•
Wideoperatingtemperaturerange:-40to85°C(-40to185°F)
•
Hot-swappableinterfaceandpowermodulesforcontinuousoperation
•
IEEE1588hardwaretimestampsupported
•
SupportsIEEEC37.238andIEC61850-9-4powerprofiles
•
IEC62439-3Clause4(PRP)andClause5(HSR)compliant
•
GOOSECheckforeasytroubleshooting
•
Built-inMMSserverbasedonIEC61850-90-4switchdatamodelingfor
powerSCADA
Certifications
Introduction
ThePT-G7728Seriesmodularswitchesprovideupto28Gigabitports,including4fixedports,6interfacemoduleslots,and2powermoduleslots
-G7728Seriesisdesignedtomeetevolvingnetworkrequirements,featuringahot-
swappablemoduledesignthatenablesyoutochange,add,orremovemoduleswithouthavingtoshutdowntheswitch.
Multipletypesofinterfacemodules(RJ45,SFP,PoE,PRP/HSR)andpowerunits(24/48VDC,110/220VAC/VDC)provideevengreaterflexibilityto
-G7728SeriescomplieswiththeIEC61850-3Edition2Class2standardtoensurereliabledata
transmissionswhenthedeviceissubjectedtohighlevelsofEMI,shock,orvibration.
Specifications
EthernetInterface
10/100/1000BaseT(X)Ports(RJ45connector)
100/1000BaseSFPPorts
Module
SlotCombination
2
2
6
SeetheLM-7000HdatasheetforinformationabouttheEthernet,PoE+,andPRP/HSR
modules.
IEEE802.3for10BaseT
IEEE802.3ufor100BaseT(X)and100BaseFX
IEEE802.3abfor1000BaseT(X)
IEEE802.3zfor1000BaseX
IEEE802.1D-2004forSpanningTreeProtocol
IEEE802.1wforRapidSpanningTreeProtocol
IEEE802.1pforClassofService
IEEE802.1QforVLANTagging
IEEE802.1Xforauthentication
IEEE802.3adforPortTrunkwithLACP
IEEE802.3xforflowcontrol
Standards
1
EthernetSoftwareFeatures
ManagementIPv4/IPv6
SNMPInform
SNMPv1/v2c/v3
DHCPServer/Client
DHCPOption66/67/82
BOOTP
TFTP
LLDP
RARP
HTTP
HTTPS
Telnet
Flowcontrol
BackPressureFlowControl
PortMirror
Fibercheck
DyingGasp
SMTP
Syslog
MIB-II
Ethernet-likeMIB
BridgeMIB
P-BRIDGEMIB
Q-BRIDGEMIB
RSTPMIB
RMONMIBGroups1,2,3,9
IGMPv1/v2/v3
GMRP
GVRP
802.1Q
QinQVLAN
LinkAggregation
MSTP
RSTP
STP
TurboChain
TurboRingv1/v2
V-ON
MRP
RADIUS
TACACS+
SSH
PortLock
Broadcaststormprotection
MABauthentication
StickyMAC
Accesscontrollist
NTPServer/Client
SNTP
IEEE1588v2PTP(hardware-based)
IEC61850QoS
GOOSECheck
EtherNet/IP
ModbusTCP
MIB
Filter
RedundancyProtocols
Security
TimeManagement
PowerSubstation
IndustrialProtocols
SwitchProperties
PriorityQueues
s
VLANIDRange
IGMPGroups
8
256
1to4094
4096
2
MACTableSize
PacketBufferSize
JumboFrameSize
16K
12Mbits
9.6KB
SerialInterface
ConsolePortRS-232(RJ45)
USBInterface
StoragePortUSBTypeA
PowerParameters
InputVoltageWithPWR-HV-P48installed:
110/220VDC/VACfortheswitchsystem
48VDCforPoEsystem(53to57VDCisrecommendedforPoE+devices)
WithPWR-LV-P48installed:
24/48VDCfortheswitchsystem
48VDCforPoEsystem(53to57VDCisrecommendedforPoE+devices)
WithPWR-HV-NPinstalled:
110/220VDC/VACfortheswitchsystem
WithPWR-LV-NPinstalled:
24/48VDCfortheswitchsystem
OperatingVoltageWithPWR-HV-P48installed:
88to300VDC,90to264VACfortheswitchsystem
46to57VDCforPoEsystems
WithPWR-LV-P48installed:
18to72VDCfortheswitchsystem
46to57VDCforPoEsystems
WithPWR-HV-NPinstalled:
88to300VDC,90to264VACfortheswitchsystem
WithPWR-LV-NPinstalled:
18to72VDCfortheswitchsystem
InputCurrentWithPWR-HV-P48installed:
PWRinputcurrent(switchsystem)
Max.0.11A@110VDC
Max.0.06A@220VDC
Max.0.29A@110VAC
Max.0.18A@220VAC
EPSinputcurrent(PoEsystem)
Max.0.53A@48VDC
(excludingpowerconsumptionofPoEdevices)
WithPWR-LV-P48installed:
PWRinputcurrent(switchsystem)
Max.0.53A@24VDC
Max.0.28A@48VDC
EPSinputcurrent(PoEsystem)
Max.0.53A@48VDC
(excludingpowerconsumptionofPoEdevices)
WithPWR-HV-NPinstalled:
PWRinputcurrent(switchsystem)
Max.0.11A@110VDC
Max.0.06A@220VDC
Max.0.29A@110VAC
Max.0.18A@220VAC
WithPWR-LV-NPinstalled:
PWRinputcurrent(switchsystem)
Max.0.53A@24VDC
Max.0.28A@48VDC
3
PhysicalCharacteristics
IPRating
Dimensions
Weight
Installation
IP30
443x44x280mm(17.44x1.73x11.02in)
3080g(6.8lb)
19-inchrackmounting
EnvironmentalLimits
OperatingTemperature
StorageTemperature(packageincluded)
AmbientRelativeHumidity
-40to85°C(-40to185°F)
-40to85°C(-40to185°F)
5to95%(non-condensing)
StandardsandCertifications
EMC
EMI
EMS
EN55032/35
CISPR32,FCCPart15BClassA
IEC61000-4-2ESD:Contact:8kV;Air:15kV
IEC61000-4-3RS:80MHzto1GHz:20V/m
IEC61000-4-4EFT:Power:4kV;Signal:4kV
IEC61000-4-5Surge:Power:4kV;Signal:4kV
IEC61000-4-6CS:10V
IEC61000-4-8PFMF
IEC61850-3Edition2Class2(EMC)
IEEE1613
EN50121-4
IEC62368-1
UL62368-1
PowerSubstation
Railway
Safety
MTBF
Time
Standards
449,542hrs
Telcordia(Bellcore),GB
Warranty
WarrantyPeriod
Details
5years
/warranty
PackageContents
Device
Cable
InstallationKit
1xPT-G7728Seriesswitch
USBcable(TypeAmaletoMicroUSBtypeB)
2xcap,forMicro-BUSBport
1xcap,metal,forABC-02USBstorageport
2xrack-mountingear
2xcap,plastic,forSFPslot
1xquickinstallationguide
1xwarrantycard
1xsubstancedisclosuretable
1xproductcertificatesofqualityinspection,SimplifiedChinese
1xproductnotice,SimplifiedChinese
SFPmodules,modulesfromtheLM-7000HModuleSeries,and/ormodulesfromthe
PWRPowerModuleSeriesneedtobepurchasedseparatelyforusewiththisproduct.
Documentation
Note
4
Dimensions
OrderingInformation
ModelNameLayer
100/1000BaseSFP
Slots
2to26
10/100/1000BaseT(X)
Ports
RJ45Connector
2to26
PoEPorts,10/100/
1000BaseT(X)
RJ45Connector
0to24
OperatingTemp.
PT-G77282-40to85°C
Accessories(soldseparately)
StorageKits
ABC-02-USB
ABC-02-USB-T
Configurationbackupandrestorationtool,firmwareupgrade,andlogfilestoragetoolformanaged
Ethernetswitchesandrouters,0to60°Coperatingtemperature
Configurationbackupandrestorationtool,firmwareupgrade,andlogfilestoragetoolformanaged
Ethernetswitchesandrouters,-40to75°Coperatingtemperature
PowerSupplies
PWR-HV-P48
PWR-LV-P48
PWR-HV-NP
PWR-LV-NP
Powersupplymodule(110/220VAC/VDC)withsystempowerinput,relay,PoEpowerinput
Powersupplymodule(24/48VDC)withsystempowerinput,relay,PoEpowerinput
Powersupplymodule(110/220VAC/VDC)withsystempowerinput,relay
Powersupplymodule(24/48VDC)withsystempowerinput,relay
LM-7000HModuleSeries
LM-7000H-4GTX
LM-7000H-4GSFP
LM-7000H-4GPoE
LM-7000H-4TX
LM-7000H-4PoE
LM-7000H-2GPHR
GigabitEthernetmodulewith410/100/1000BaseT(X)ports
GigabitEthernetmodulewith4100/1000BaseSFPslots
GigabitEthernetmodulewith410/100/1000BaseT(X)IEEE802.3af/atPoE+ports
FastEthernetmodulewith410/100BaseT(X)ports
FastEthernetmodulewith410/100BaseT(X)IEEE802.3af/atPoE+ports
GigabitEthernetmodulewith2100/1000BaseT(X)PRP/HSRor100/1000BaseSFPPRP/HSRcombo
ports,-40to75°Coperatingtemperature
SFPModules
5
SFP-1FELLC-T
SFP-1FEMLC-T
SFP-1FESLC-T
SFP-1GEZXLC
SFP-1G10ALC
SFP-1G10ALC-T
SFP-1G10BLC
SFP-1G10BLC-T
SFP-1G20ALC
SFP-1G20ALC-T
SFP-1G20BLC
SFP-1G20BLC-T
SFP-1G40ALC
SFP-1G40ALC-T
SFP-1G40BLC
SFP-1G40BLC-T
SFP-1GEZXLC-120
SFP-1GLHLC
SFP-1GLHLC-T
SFP-1GLHXLC
SFP-1GLHXLC-T
SFP-1GLSXLC
SFP-1GLSXLC-T
SFP-1GLXLC
SFP-1GLXLC-T
SFP-1GSXLC
SFP-1GSXLC-T
SFP-1GZXLC
SFPmodulewith1100Basesingle-modewithLCconnectorfor80kmtransmission,-40to85°C
operatingtemperature
SFPmodulewith1100Basemulti-mode,LCconnectorfor2/4kmtransmission,-40to85°Coperating
temperature
SFPmodulewith1100Basesingle-modewithLCconnectorfor40kmtransmission,-40to85°C
operatingtemperature
SFPmodulewith11000BaseEZXportwithLCconnectorfor110kmtransmission,0to60°Coperating
temperature
WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor10kmtransmission;TX
1310nm,RX1550nm,0to60°Coperatingtemperature
WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor10kmtransmission;TX
1310nm,RX1550nm,-40to85°Coperatingtemperature
WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor10kmtransmission;TX
1550nm,RX1310nm,0to60°Coperatingtemperature
WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor10kmtransmission;TX
1550nm,RX1310nm,-40to85°Coperatingtemperature
WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor20kmtransmission;TX
1310nm,RX1550nm,0to60°Coperatingtemperature
WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor20kmtransmission;TX
1310nm,RX1550nm,-40to85°Coperatingtemperature
WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor20kmtransmission;TX
1550nm,RX1310nm,0to60°Coperatingtemperature
WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor20kmtransmission;TX
1550nm,RX1310nm,-40to85°Coperatingtemperature
WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor40kmtransmission;TX
1310nm,RX1550nm,0to60°Coperatingtemperature
WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor40kmtransmission;TX
1310nm,RX1550nm,-40to85°Coperatingtemperature
WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor40kmtransmission;TX
1550nm,RX1310nm,0to60°Coperatingtemperature
WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor40kmtransmission;TX
1550nm,RX1310nm,-40to85°Coperatingtemperature
SFPmodulewith11000BaseEZXportwithLCconnectorfor120kmtransmission,0to60°Coperating
temperature
SFPmodulewith11000BaseLHportwithLCconnectorfor30kmtransmission,0to60°Coperating
temperature
SFPmodulewith11000BaseLHportwithLCconnectorfor30kmtransmission,-40to85°Coperating
temperature
SFPmodulewith11000BaseLHXportwithLCconnectorfor40kmtransmission,0to60°Coperating
temperature
SFPmodulewith11000BaseLHXportwithLCconnectorfor40kmtransmission,-40to85°C
operatingtemperature
SFPmodulewith11000BaseLSXportwithLCconnectorfor1km/2kmtransmission,0to60°C
operatingtemperature
SFPmodulewith11000BaseLSXportwithLCconnectorfor1km/2kmtransmission,-40to85°C
operatingtemperature
SFPmodulewith11000BaseLXportwithLCconnectorfor10kmtransmission,0to60°Coperating
temperature
SFPmodulewith11000BaseLXportwithLCconnectorfor10kmtransmission,-40to85°Coperating
temperature
SFPmodulewith11000BaseSXportwithLCconnectorfor300m/550mtransmission,0to60°C
operatingtemperature
SFPmodulewith11000BaseSXportwithLCconnectorfor300m/550mtransmission,-40to85°C
operatingtemperature
SFPmodulewith11000BaseZXportwithLCconnectorfor80kmtransmission,0to60°Coperating
temperature
6
SFP-1GZXLC-TSFPmodulewith11000BaseZXportwithLCconnectorfor80kmtransmission,-40to85°Coperating
temperature
Software
MXview-50
MXview-100
MXview-250
MXview-500
MXview-1000
MXview-2000
MXviewUpgrade-50
MXviewlicensefor50nodes
MXviewlicensefor100nodes
MXviewlicensefor250nodes
MXviewlicensefor500nodes
MXviewlicensefor1000nodes
MXviewlicensefor2000nodes
MXviewlicenseexpansionfor50nodes
©dAug28,2023.
Thisdocumentandanyportionthereofmaynotbereproducedorusedinanymannerwhatsoeverwithouttheexpresswrittenpermissionof
urwebsiteforthemostup-to-dateproductinformation.
7