MOXA PT-G7728系列28口层2全光纤模块 managed Ethernet 交换机说明

IT圈 admin 22浏览 0评论

2024年10月27日发(作者:史迎梅)

PT-G7728Series

IEC61850-328-portLayer2fullGigabitmodularmanagedEthernetswitches

FeaturesandBenefits

IEC61850-3Edition2Class2compliantforEMC

Wideoperatingtemperaturerange:-40to85°C(-40to185°F)

Hot-swappableinterfaceandpowermodulesforcontinuousoperation

IEEE1588hardwaretimestampsupported

SupportsIEEEC37.238andIEC61850-9-4powerprofiles

IEC62439-3Clause4(PRP)andClause5(HSR)compliant

GOOSECheckforeasytroubleshooting

Built-inMMSserverbasedonIEC61850-90-4switchdatamodelingfor

powerSCADA

Certifications

Introduction

ThePT-G7728Seriesmodularswitchesprovideupto28Gigabitports,including4fixedports,6interfacemoduleslots,and2powermoduleslots

-G7728Seriesisdesignedtomeetevolvingnetworkrequirements,featuringahot-

swappablemoduledesignthatenablesyoutochange,add,orremovemoduleswithouthavingtoshutdowntheswitch.

Multipletypesofinterfacemodules(RJ45,SFP,PoE,PRP/HSR)andpowerunits(24/48VDC,110/220VAC/VDC)provideevengreaterflexibilityto

-G7728SeriescomplieswiththeIEC61850-3Edition2Class2standardtoensurereliabledata

transmissionswhenthedeviceissubjectedtohighlevelsofEMI,shock,orvibration.

Specifications

EthernetInterface

10/100/1000BaseT(X)Ports(RJ45connector)

100/1000BaseSFPPorts

Module

SlotCombination

2

2

6

SeetheLM-7000HdatasheetforinformationabouttheEthernet,PoE+,andPRP/HSR

modules.

IEEE802.3for10BaseT

IEEE802.3ufor100BaseT(X)and100BaseFX

IEEE802.3abfor1000BaseT(X)

IEEE802.3zfor1000BaseX

IEEE802.1D-2004forSpanningTreeProtocol

IEEE802.1wforRapidSpanningTreeProtocol

IEEE802.1pforClassofService

IEEE802.1QforVLANTagging

IEEE802.1Xforauthentication

IEEE802.3adforPortTrunkwithLACP

IEEE802.3xforflowcontrol

Standards

1

EthernetSoftwareFeatures

ManagementIPv4/IPv6

SNMPInform

SNMPv1/v2c/v3

DHCPServer/Client

DHCPOption66/67/82

BOOTP

TFTP

LLDP

RARP

HTTP

HTTPS

Telnet

Flowcontrol

BackPressureFlowControl

PortMirror

Fibercheck

DyingGasp

SMTP

Syslog

MIB-II

Ethernet-likeMIB

BridgeMIB

P-BRIDGEMIB

Q-BRIDGEMIB

RSTPMIB

RMONMIBGroups1,2,3,9

IGMPv1/v2/v3

GMRP

GVRP

802.1Q

QinQVLAN

LinkAggregation

MSTP

RSTP

STP

TurboChain

TurboRingv1/v2

V-ON

MRP

RADIUS

TACACS+

SSH

PortLock

Broadcaststormprotection

MABauthentication

StickyMAC

Accesscontrollist

NTPServer/Client

SNTP

IEEE1588v2PTP(hardware-based)

IEC61850QoS

GOOSECheck

EtherNet/IP

ModbusTCP

MIB

Filter

RedundancyProtocols

Security

TimeManagement

PowerSubstation

IndustrialProtocols

SwitchProperties

PriorityQueues

s

VLANIDRange

IGMPGroups

8

256

1to4094

4096

2

MACTableSize

PacketBufferSize

JumboFrameSize

16K

12Mbits

9.6KB

SerialInterface

ConsolePortRS-232(RJ45)

USBInterface

StoragePortUSBTypeA

PowerParameters

InputVoltageWithPWR-HV-P48installed:

110/220VDC/VACfortheswitchsystem

48VDCforPoEsystem(53to57VDCisrecommendedforPoE+devices)

WithPWR-LV-P48installed:

24/48VDCfortheswitchsystem

48VDCforPoEsystem(53to57VDCisrecommendedforPoE+devices)

WithPWR-HV-NPinstalled:

110/220VDC/VACfortheswitchsystem

WithPWR-LV-NPinstalled:

24/48VDCfortheswitchsystem

OperatingVoltageWithPWR-HV-P48installed:

88to300VDC,90to264VACfortheswitchsystem

46to57VDCforPoEsystems

WithPWR-LV-P48installed:

18to72VDCfortheswitchsystem

46to57VDCforPoEsystems

WithPWR-HV-NPinstalled:

88to300VDC,90to264VACfortheswitchsystem

WithPWR-LV-NPinstalled:

18to72VDCfortheswitchsystem

InputCurrentWithPWR-HV-P48installed:

PWRinputcurrent(switchsystem)

Max.0.11A@110VDC

Max.0.06A@220VDC

Max.0.29A@110VAC

Max.0.18A@220VAC

EPSinputcurrent(PoEsystem)

Max.0.53A@48VDC

(excludingpowerconsumptionofPoEdevices)

WithPWR-LV-P48installed:

PWRinputcurrent(switchsystem)

Max.0.53A@24VDC

Max.0.28A@48VDC

EPSinputcurrent(PoEsystem)

Max.0.53A@48VDC

(excludingpowerconsumptionofPoEdevices)

WithPWR-HV-NPinstalled:

PWRinputcurrent(switchsystem)

Max.0.11A@110VDC

Max.0.06A@220VDC

Max.0.29A@110VAC

Max.0.18A@220VAC

WithPWR-LV-NPinstalled:

PWRinputcurrent(switchsystem)

Max.0.53A@24VDC

Max.0.28A@48VDC

3

PhysicalCharacteristics

IPRating

Dimensions

Weight

Installation

IP30

443x44x280mm(17.44x1.73x11.02in)

3080g(6.8lb)

19-inchrackmounting

EnvironmentalLimits

OperatingTemperature

StorageTemperature(packageincluded)

AmbientRelativeHumidity

-40to85°C(-40to185°F)

-40to85°C(-40to185°F)

5to95%(non-condensing)

StandardsandCertifications

EMC

EMI

EMS

EN55032/35

CISPR32,FCCPart15BClassA

IEC61000-4-2ESD:Contact:8kV;Air:15kV

IEC61000-4-3RS:80MHzto1GHz:20V/m

IEC61000-4-4EFT:Power:4kV;Signal:4kV

IEC61000-4-5Surge:Power:4kV;Signal:4kV

IEC61000-4-6CS:10V

IEC61000-4-8PFMF

IEC61850-3Edition2Class2(EMC)

IEEE1613

EN50121-4

IEC62368-1

UL62368-1

PowerSubstation

Railway

Safety

MTBF

Time

Standards

449,542hrs

Telcordia(Bellcore),GB

Warranty

WarrantyPeriod

Details

5years

/warranty

PackageContents

Device

Cable

InstallationKit

1xPT-G7728Seriesswitch

USBcable(TypeAmaletoMicroUSBtypeB)

2xcap,forMicro-BUSBport

1xcap,metal,forABC-02USBstorageport

2xrack-mountingear

2xcap,plastic,forSFPslot

1xquickinstallationguide

1xwarrantycard

1xsubstancedisclosuretable

1xproductcertificatesofqualityinspection,SimplifiedChinese

1xproductnotice,SimplifiedChinese

SFPmodules,modulesfromtheLM-7000HModuleSeries,and/ormodulesfromthe

PWRPowerModuleSeriesneedtobepurchasedseparatelyforusewiththisproduct.

Documentation

Note

4

Dimensions

OrderingInformation

ModelNameLayer

100/1000BaseSFP

Slots

2to26

10/100/1000BaseT(X)

Ports

RJ45Connector

2to26

PoEPorts,10/100/

1000BaseT(X)

RJ45Connector

0to24

OperatingTemp.

PT-G77282-40to85°C

Accessories(soldseparately)

StorageKits

ABC-02-USB

ABC-02-USB-T

Configurationbackupandrestorationtool,firmwareupgrade,andlogfilestoragetoolformanaged

Ethernetswitchesandrouters,0to60°Coperatingtemperature

Configurationbackupandrestorationtool,firmwareupgrade,andlogfilestoragetoolformanaged

Ethernetswitchesandrouters,-40to75°Coperatingtemperature

PowerSupplies

PWR-HV-P48

PWR-LV-P48

PWR-HV-NP

PWR-LV-NP

Powersupplymodule(110/220VAC/VDC)withsystempowerinput,relay,PoEpowerinput

Powersupplymodule(24/48VDC)withsystempowerinput,relay,PoEpowerinput

Powersupplymodule(110/220VAC/VDC)withsystempowerinput,relay

Powersupplymodule(24/48VDC)withsystempowerinput,relay

LM-7000HModuleSeries

LM-7000H-4GTX

LM-7000H-4GSFP

LM-7000H-4GPoE

LM-7000H-4TX

LM-7000H-4PoE

LM-7000H-2GPHR

GigabitEthernetmodulewith410/100/1000BaseT(X)ports

GigabitEthernetmodulewith4100/1000BaseSFPslots

GigabitEthernetmodulewith410/100/1000BaseT(X)IEEE802.3af/atPoE+ports

FastEthernetmodulewith410/100BaseT(X)ports

FastEthernetmodulewith410/100BaseT(X)IEEE802.3af/atPoE+ports

GigabitEthernetmodulewith2100/1000BaseT(X)PRP/HSRor100/1000BaseSFPPRP/HSRcombo

ports,-40to75°Coperatingtemperature

SFPModules

5

SFP-1FELLC-T

SFP-1FEMLC-T

SFP-1FESLC-T

SFP-1GEZXLC

SFP-1G10ALC

SFP-1G10ALC-T

SFP-1G10BLC

SFP-1G10BLC-T

SFP-1G20ALC

SFP-1G20ALC-T

SFP-1G20BLC

SFP-1G20BLC-T

SFP-1G40ALC

SFP-1G40ALC-T

SFP-1G40BLC

SFP-1G40BLC-T

SFP-1GEZXLC-120

SFP-1GLHLC

SFP-1GLHLC-T

SFP-1GLHXLC

SFP-1GLHXLC-T

SFP-1GLSXLC

SFP-1GLSXLC-T

SFP-1GLXLC

SFP-1GLXLC-T

SFP-1GSXLC

SFP-1GSXLC-T

SFP-1GZXLC

SFPmodulewith1100Basesingle-modewithLCconnectorfor80kmtransmission,-40to85°C

operatingtemperature

SFPmodulewith1100Basemulti-mode,LCconnectorfor2/4kmtransmission,-40to85°Coperating

temperature

SFPmodulewith1100Basesingle-modewithLCconnectorfor40kmtransmission,-40to85°C

operatingtemperature

SFPmodulewith11000BaseEZXportwithLCconnectorfor110kmtransmission,0to60°Coperating

temperature

WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor10kmtransmission;TX

1310nm,RX1550nm,0to60°Coperatingtemperature

WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor10kmtransmission;TX

1310nm,RX1550nm,-40to85°Coperatingtemperature

WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor10kmtransmission;TX

1550nm,RX1310nm,0to60°Coperatingtemperature

WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor10kmtransmission;TX

1550nm,RX1310nm,-40to85°Coperatingtemperature

WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor20kmtransmission;TX

1310nm,RX1550nm,0to60°Coperatingtemperature

WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor20kmtransmission;TX

1310nm,RX1550nm,-40to85°Coperatingtemperature

WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor20kmtransmission;TX

1550nm,RX1310nm,0to60°Coperatingtemperature

WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor20kmtransmission;TX

1550nm,RX1310nm,-40to85°Coperatingtemperature

WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor40kmtransmission;TX

1310nm,RX1550nm,0to60°Coperatingtemperature

WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor40kmtransmission;TX

1310nm,RX1550nm,-40to85°Coperatingtemperature

WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor40kmtransmission;TX

1550nm,RX1310nm,0to60°Coperatingtemperature

WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor40kmtransmission;TX

1550nm,RX1310nm,-40to85°Coperatingtemperature

SFPmodulewith11000BaseEZXportwithLCconnectorfor120kmtransmission,0to60°Coperating

temperature

SFPmodulewith11000BaseLHportwithLCconnectorfor30kmtransmission,0to60°Coperating

temperature

SFPmodulewith11000BaseLHportwithLCconnectorfor30kmtransmission,-40to85°Coperating

temperature

SFPmodulewith11000BaseLHXportwithLCconnectorfor40kmtransmission,0to60°Coperating

temperature

SFPmodulewith11000BaseLHXportwithLCconnectorfor40kmtransmission,-40to85°C

operatingtemperature

SFPmodulewith11000BaseLSXportwithLCconnectorfor1km/2kmtransmission,0to60°C

operatingtemperature

SFPmodulewith11000BaseLSXportwithLCconnectorfor1km/2kmtransmission,-40to85°C

operatingtemperature

SFPmodulewith11000BaseLXportwithLCconnectorfor10kmtransmission,0to60°Coperating

temperature

SFPmodulewith11000BaseLXportwithLCconnectorfor10kmtransmission,-40to85°Coperating

temperature

SFPmodulewith11000BaseSXportwithLCconnectorfor300m/550mtransmission,0to60°C

operatingtemperature

SFPmodulewith11000BaseSXportwithLCconnectorfor300m/550mtransmission,-40to85°C

operatingtemperature

SFPmodulewith11000BaseZXportwithLCconnectorfor80kmtransmission,0to60°Coperating

temperature

6

SFP-1GZXLC-TSFPmodulewith11000BaseZXportwithLCconnectorfor80kmtransmission,-40to85°Coperating

temperature

Software

MXview-50

MXview-100

MXview-250

MXview-500

MXview-1000

MXview-2000

MXviewUpgrade-50

MXviewlicensefor50nodes

MXviewlicensefor100nodes

MXviewlicensefor250nodes

MXviewlicensefor500nodes

MXviewlicensefor1000nodes

MXviewlicensefor2000nodes

MXviewlicenseexpansionfor50nodes

©dAug28,2023.

Thisdocumentandanyportionthereofmaynotbereproducedorusedinanymannerwhatsoeverwithouttheexpresswrittenpermissionof

urwebsiteforthemostup-to-dateproductinformation.

7

2024年10月27日发(作者:史迎梅)

PT-G7728Series

IEC61850-328-portLayer2fullGigabitmodularmanagedEthernetswitches

FeaturesandBenefits

IEC61850-3Edition2Class2compliantforEMC

Wideoperatingtemperaturerange:-40to85°C(-40to185°F)

Hot-swappableinterfaceandpowermodulesforcontinuousoperation

IEEE1588hardwaretimestampsupported

SupportsIEEEC37.238andIEC61850-9-4powerprofiles

IEC62439-3Clause4(PRP)andClause5(HSR)compliant

GOOSECheckforeasytroubleshooting

Built-inMMSserverbasedonIEC61850-90-4switchdatamodelingfor

powerSCADA

Certifications

Introduction

ThePT-G7728Seriesmodularswitchesprovideupto28Gigabitports,including4fixedports,6interfacemoduleslots,and2powermoduleslots

-G7728Seriesisdesignedtomeetevolvingnetworkrequirements,featuringahot-

swappablemoduledesignthatenablesyoutochange,add,orremovemoduleswithouthavingtoshutdowntheswitch.

Multipletypesofinterfacemodules(RJ45,SFP,PoE,PRP/HSR)andpowerunits(24/48VDC,110/220VAC/VDC)provideevengreaterflexibilityto

-G7728SeriescomplieswiththeIEC61850-3Edition2Class2standardtoensurereliabledata

transmissionswhenthedeviceissubjectedtohighlevelsofEMI,shock,orvibration.

Specifications

EthernetInterface

10/100/1000BaseT(X)Ports(RJ45connector)

100/1000BaseSFPPorts

Module

SlotCombination

2

2

6

SeetheLM-7000HdatasheetforinformationabouttheEthernet,PoE+,andPRP/HSR

modules.

IEEE802.3for10BaseT

IEEE802.3ufor100BaseT(X)and100BaseFX

IEEE802.3abfor1000BaseT(X)

IEEE802.3zfor1000BaseX

IEEE802.1D-2004forSpanningTreeProtocol

IEEE802.1wforRapidSpanningTreeProtocol

IEEE802.1pforClassofService

IEEE802.1QforVLANTagging

IEEE802.1Xforauthentication

IEEE802.3adforPortTrunkwithLACP

IEEE802.3xforflowcontrol

Standards

1

EthernetSoftwareFeatures

ManagementIPv4/IPv6

SNMPInform

SNMPv1/v2c/v3

DHCPServer/Client

DHCPOption66/67/82

BOOTP

TFTP

LLDP

RARP

HTTP

HTTPS

Telnet

Flowcontrol

BackPressureFlowControl

PortMirror

Fibercheck

DyingGasp

SMTP

Syslog

MIB-II

Ethernet-likeMIB

BridgeMIB

P-BRIDGEMIB

Q-BRIDGEMIB

RSTPMIB

RMONMIBGroups1,2,3,9

IGMPv1/v2/v3

GMRP

GVRP

802.1Q

QinQVLAN

LinkAggregation

MSTP

RSTP

STP

TurboChain

TurboRingv1/v2

V-ON

MRP

RADIUS

TACACS+

SSH

PortLock

Broadcaststormprotection

MABauthentication

StickyMAC

Accesscontrollist

NTPServer/Client

SNTP

IEEE1588v2PTP(hardware-based)

IEC61850QoS

GOOSECheck

EtherNet/IP

ModbusTCP

MIB

Filter

RedundancyProtocols

Security

TimeManagement

PowerSubstation

IndustrialProtocols

SwitchProperties

PriorityQueues

s

VLANIDRange

IGMPGroups

8

256

1to4094

4096

2

MACTableSize

PacketBufferSize

JumboFrameSize

16K

12Mbits

9.6KB

SerialInterface

ConsolePortRS-232(RJ45)

USBInterface

StoragePortUSBTypeA

PowerParameters

InputVoltageWithPWR-HV-P48installed:

110/220VDC/VACfortheswitchsystem

48VDCforPoEsystem(53to57VDCisrecommendedforPoE+devices)

WithPWR-LV-P48installed:

24/48VDCfortheswitchsystem

48VDCforPoEsystem(53to57VDCisrecommendedforPoE+devices)

WithPWR-HV-NPinstalled:

110/220VDC/VACfortheswitchsystem

WithPWR-LV-NPinstalled:

24/48VDCfortheswitchsystem

OperatingVoltageWithPWR-HV-P48installed:

88to300VDC,90to264VACfortheswitchsystem

46to57VDCforPoEsystems

WithPWR-LV-P48installed:

18to72VDCfortheswitchsystem

46to57VDCforPoEsystems

WithPWR-HV-NPinstalled:

88to300VDC,90to264VACfortheswitchsystem

WithPWR-LV-NPinstalled:

18to72VDCfortheswitchsystem

InputCurrentWithPWR-HV-P48installed:

PWRinputcurrent(switchsystem)

Max.0.11A@110VDC

Max.0.06A@220VDC

Max.0.29A@110VAC

Max.0.18A@220VAC

EPSinputcurrent(PoEsystem)

Max.0.53A@48VDC

(excludingpowerconsumptionofPoEdevices)

WithPWR-LV-P48installed:

PWRinputcurrent(switchsystem)

Max.0.53A@24VDC

Max.0.28A@48VDC

EPSinputcurrent(PoEsystem)

Max.0.53A@48VDC

(excludingpowerconsumptionofPoEdevices)

WithPWR-HV-NPinstalled:

PWRinputcurrent(switchsystem)

Max.0.11A@110VDC

Max.0.06A@220VDC

Max.0.29A@110VAC

Max.0.18A@220VAC

WithPWR-LV-NPinstalled:

PWRinputcurrent(switchsystem)

Max.0.53A@24VDC

Max.0.28A@48VDC

3

PhysicalCharacteristics

IPRating

Dimensions

Weight

Installation

IP30

443x44x280mm(17.44x1.73x11.02in)

3080g(6.8lb)

19-inchrackmounting

EnvironmentalLimits

OperatingTemperature

StorageTemperature(packageincluded)

AmbientRelativeHumidity

-40to85°C(-40to185°F)

-40to85°C(-40to185°F)

5to95%(non-condensing)

StandardsandCertifications

EMC

EMI

EMS

EN55032/35

CISPR32,FCCPart15BClassA

IEC61000-4-2ESD:Contact:8kV;Air:15kV

IEC61000-4-3RS:80MHzto1GHz:20V/m

IEC61000-4-4EFT:Power:4kV;Signal:4kV

IEC61000-4-5Surge:Power:4kV;Signal:4kV

IEC61000-4-6CS:10V

IEC61000-4-8PFMF

IEC61850-3Edition2Class2(EMC)

IEEE1613

EN50121-4

IEC62368-1

UL62368-1

PowerSubstation

Railway

Safety

MTBF

Time

Standards

449,542hrs

Telcordia(Bellcore),GB

Warranty

WarrantyPeriod

Details

5years

/warranty

PackageContents

Device

Cable

InstallationKit

1xPT-G7728Seriesswitch

USBcable(TypeAmaletoMicroUSBtypeB)

2xcap,forMicro-BUSBport

1xcap,metal,forABC-02USBstorageport

2xrack-mountingear

2xcap,plastic,forSFPslot

1xquickinstallationguide

1xwarrantycard

1xsubstancedisclosuretable

1xproductcertificatesofqualityinspection,SimplifiedChinese

1xproductnotice,SimplifiedChinese

SFPmodules,modulesfromtheLM-7000HModuleSeries,and/ormodulesfromthe

PWRPowerModuleSeriesneedtobepurchasedseparatelyforusewiththisproduct.

Documentation

Note

4

Dimensions

OrderingInformation

ModelNameLayer

100/1000BaseSFP

Slots

2to26

10/100/1000BaseT(X)

Ports

RJ45Connector

2to26

PoEPorts,10/100/

1000BaseT(X)

RJ45Connector

0to24

OperatingTemp.

PT-G77282-40to85°C

Accessories(soldseparately)

StorageKits

ABC-02-USB

ABC-02-USB-T

Configurationbackupandrestorationtool,firmwareupgrade,andlogfilestoragetoolformanaged

Ethernetswitchesandrouters,0to60°Coperatingtemperature

Configurationbackupandrestorationtool,firmwareupgrade,andlogfilestoragetoolformanaged

Ethernetswitchesandrouters,-40to75°Coperatingtemperature

PowerSupplies

PWR-HV-P48

PWR-LV-P48

PWR-HV-NP

PWR-LV-NP

Powersupplymodule(110/220VAC/VDC)withsystempowerinput,relay,PoEpowerinput

Powersupplymodule(24/48VDC)withsystempowerinput,relay,PoEpowerinput

Powersupplymodule(110/220VAC/VDC)withsystempowerinput,relay

Powersupplymodule(24/48VDC)withsystempowerinput,relay

LM-7000HModuleSeries

LM-7000H-4GTX

LM-7000H-4GSFP

LM-7000H-4GPoE

LM-7000H-4TX

LM-7000H-4PoE

LM-7000H-2GPHR

GigabitEthernetmodulewith410/100/1000BaseT(X)ports

GigabitEthernetmodulewith4100/1000BaseSFPslots

GigabitEthernetmodulewith410/100/1000BaseT(X)IEEE802.3af/atPoE+ports

FastEthernetmodulewith410/100BaseT(X)ports

FastEthernetmodulewith410/100BaseT(X)IEEE802.3af/atPoE+ports

GigabitEthernetmodulewith2100/1000BaseT(X)PRP/HSRor100/1000BaseSFPPRP/HSRcombo

ports,-40to75°Coperatingtemperature

SFPModules

5

SFP-1FELLC-T

SFP-1FEMLC-T

SFP-1FESLC-T

SFP-1GEZXLC

SFP-1G10ALC

SFP-1G10ALC-T

SFP-1G10BLC

SFP-1G10BLC-T

SFP-1G20ALC

SFP-1G20ALC-T

SFP-1G20BLC

SFP-1G20BLC-T

SFP-1G40ALC

SFP-1G40ALC-T

SFP-1G40BLC

SFP-1G40BLC-T

SFP-1GEZXLC-120

SFP-1GLHLC

SFP-1GLHLC-T

SFP-1GLHXLC

SFP-1GLHXLC-T

SFP-1GLSXLC

SFP-1GLSXLC-T

SFP-1GLXLC

SFP-1GLXLC-T

SFP-1GSXLC

SFP-1GSXLC-T

SFP-1GZXLC

SFPmodulewith1100Basesingle-modewithLCconnectorfor80kmtransmission,-40to85°C

operatingtemperature

SFPmodulewith1100Basemulti-mode,LCconnectorfor2/4kmtransmission,-40to85°Coperating

temperature

SFPmodulewith1100Basesingle-modewithLCconnectorfor40kmtransmission,-40to85°C

operatingtemperature

SFPmodulewith11000BaseEZXportwithLCconnectorfor110kmtransmission,0to60°Coperating

temperature

WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor10kmtransmission;TX

1310nm,RX1550nm,0to60°Coperatingtemperature

WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor10kmtransmission;TX

1310nm,RX1550nm,-40to85°Coperatingtemperature

WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor10kmtransmission;TX

1550nm,RX1310nm,0to60°Coperatingtemperature

WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor10kmtransmission;TX

1550nm,RX1310nm,-40to85°Coperatingtemperature

WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor20kmtransmission;TX

1310nm,RX1550nm,0to60°Coperatingtemperature

WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor20kmtransmission;TX

1310nm,RX1550nm,-40to85°Coperatingtemperature

WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor20kmtransmission;TX

1550nm,RX1310nm,0to60°Coperatingtemperature

WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor20kmtransmission;TX

1550nm,RX1310nm,-40to85°Coperatingtemperature

WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor40kmtransmission;TX

1310nm,RX1550nm,0to60°Coperatingtemperature

WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor40kmtransmission;TX

1310nm,RX1550nm,-40to85°Coperatingtemperature

WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor40kmtransmission;TX

1550nm,RX1310nm,0to60°Coperatingtemperature

WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor40kmtransmission;TX

1550nm,RX1310nm,-40to85°Coperatingtemperature

SFPmodulewith11000BaseEZXportwithLCconnectorfor120kmtransmission,0to60°Coperating

temperature

SFPmodulewith11000BaseLHportwithLCconnectorfor30kmtransmission,0to60°Coperating

temperature

SFPmodulewith11000BaseLHportwithLCconnectorfor30kmtransmission,-40to85°Coperating

temperature

SFPmodulewith11000BaseLHXportwithLCconnectorfor40kmtransmission,0to60°Coperating

temperature

SFPmodulewith11000BaseLHXportwithLCconnectorfor40kmtransmission,-40to85°C

operatingtemperature

SFPmodulewith11000BaseLSXportwithLCconnectorfor1km/2kmtransmission,0to60°C

operatingtemperature

SFPmodulewith11000BaseLSXportwithLCconnectorfor1km/2kmtransmission,-40to85°C

operatingtemperature

SFPmodulewith11000BaseLXportwithLCconnectorfor10kmtransmission,0to60°Coperating

temperature

SFPmodulewith11000BaseLXportwithLCconnectorfor10kmtransmission,-40to85°Coperating

temperature

SFPmodulewith11000BaseSXportwithLCconnectorfor300m/550mtransmission,0to60°C

operatingtemperature

SFPmodulewith11000BaseSXportwithLCconnectorfor300m/550mtransmission,-40to85°C

operatingtemperature

SFPmodulewith11000BaseZXportwithLCconnectorfor80kmtransmission,0to60°Coperating

temperature

6

SFP-1GZXLC-TSFPmodulewith11000BaseZXportwithLCconnectorfor80kmtransmission,-40to85°Coperating

temperature

Software

MXview-50

MXview-100

MXview-250

MXview-500

MXview-1000

MXview-2000

MXviewUpgrade-50

MXviewlicensefor50nodes

MXviewlicensefor100nodes

MXviewlicensefor250nodes

MXviewlicensefor500nodes

MXviewlicensefor1000nodes

MXviewlicensefor2000nodes

MXviewlicenseexpansionfor50nodes