22-1797-16-EN

Product Data

4YCY4024 through 4YCY4060

Packaged Convertible Gas/Electric

14 SEER

2 - 5 Ton, 60 - 120 MBTU

R-410A

©

2014 Trane

Pub. No. 22-1797-16-EN

It's Hard to Stop a Trane.

Packaged Convertible Gas/Electric System

Trane offers a complete family of packaged gas/electric heating and cooling systems,

designed to give you the unbeatable combination of energy efficiency and lower operat-

ing costs. In warm weather, the packaged gas/electric system functions as an all-electric,

high efficiency air conditioner. In cold weather, it operates as a natural gas or propane gas

furnace, offering you the best of both energy worlds.

Introducing the new TRANE Packaged Convertible Gas/Elec-

tric System.

Single Packaged Convertible Gas/

Electric Systems are easy and ver-

satile to install. Because cooling and

heating functions are all contained in a

single cabinet, a Trane single packaged

convertible gas/electric system is easy to

install and service. It can be flush mount-

ed beside your home at ground level

or placed on the roof for horizontal or

downflow installation. When connected to

an optional Trane thermostat control, and

air distribution ducts, you have a highly

efficient, total home comfort system.

Single Packaged Convertible Gas/

Electric Systems are unmatched in

quality and reliability. All major com-

ponents on these products, including

the compressor, have been designed

and manufactured for maximum service.

Every Climatuff

®

compressor is de-

signed and manufactured to exacting

specifications. Each design is life tested

in extreme environments to ensure

reliable and long lasting operation in

normal applications. Each compressor

has internal motor protection for added

reliability.

2

3

Contents

Optional Equipment Listing 4

General Data 5

Performance Data

Indoor Fan 9

Typical Wiring 13

Optional Equipment 16

Dimensional Data 21

Mechanical Specifications 27

Optional Equipment Listing

OPTIONAL EQUIPMENT FOR PACKAGED UNITS (check mark [3] indicates accessories included)

Hinged Filter Access Door (4YCY4024-036) 8 ................................................................BAYACCDOR1A[ ]

Hinged Filter Access Door (4YCY4042-060) 8 ..............................................................BAYACCDOR2A[ ]

Roof Curb Full Perimeter (4YCY4024-36) 3 .....................................................................BAYCURB050A[ ]

Roof Curb Full Perimeter (4YCY4042-60) 3 .....................................................................BAYCURB051A[ ]

Roof Curb Utility Extension Kit (BAYCURB050A)....................................................................BAYUTIL101B[ ]

Roof Curb Utility Extension Kit (BAYCURB051A)....................................................................BAYUTIL102B[ ]

0-25% Manual Fresh Air Damper (4YCY4024-36) 1. ..........................................................BAYOSAH001A[ ]

0-25% Manual Fresh Air Damper (4YCY4042-60) 1. ..........................................................BAYOSAH002A[ ]

Motorized Fresh Air Damper (4YCY4024-36) 1. ...............................................................BAYDMPR101A[ ]

Motorized Fresh Air Damper (4YCY4042-60) 1. ................................................................BAYDMPR102A[ ]

16" Round Duct Adapter (2 per box) (4YCY4024-36) 6 ....................................................BAYSQRD001A[ ]

18" Round Duct Adapter (2 per box) (4YCY4024-60) 6 ....................................................BAYSQRD002A[ ]

0-100% Mod Economizer w/Baro. Relief (4YCY4024-36) 124 .......................................BAYECON101B[ ]

0-100% Mod. Economizer w/Baro. Relief (4YCY4042-60) 124. ......................................BAYECON102B[ ]

0-100% Horizontal Economizer (4YCY4024-36) 12 . .......................................................BAYECON200A[ ]

0-100% Horizontal Economizer (4YCY4042-60) 12 . .......................................................BAYECON201A[ ]

Enthalpy Control for Economizer (solid state). ......................................................................BAYENTH001A[ ]

Remote Potentiometer (All-BAYECON***A) .............................................................................BAYSTAT023[ ]

1"-2" Filter Frame (4YCY4024-36) (20 x 25 filter not included) 1. ............BAYFLTR101B[ ]

1"-2" Filter Frame (4YCY4042-60) (20 x 20 & 20 x 18 filter not included) 1. .......BAYFLTR201B[ ]

LP Conversion Kit (All 40K, 120K Models) ...........................................................................BAYLPKT100A[ ]

LP Conversion Kit (All 64K, 96K Models) .............................................................................BAYLPKT101A[ ]

LP Conversion Kit (All 75K Models).......................................................................................BAYLPKT102A[ ]

Head Pressure Control (Low Ambient Cool) (208/240v) Kit 5. ...........................................BAYLOAM105A[ ]

Quick Start Kit (4YCY4-‡1) ..................................................................................................BAYQSKT301A[ ]

Crankcase Heater Recip (4YCY4024-030) (230v) 5. ..........................................................BAYCCHT101A[ ]

Crankcase Heater Scroll (4YCY4042-060‡1/3)(230v) 5. ....................................................BAYCCHT102A[ ]

Crankcase Heater Scroll (4YCY4036)(230v) 5. ..................................................................BAYCCHT103A[ ]

Adapter Curb 4YCY4024-036 to BAYADAP050A[ ]

Adapter Curb 4YCY4024-036 BAYADAP051A[ ]

Adapter Curb 4YCY4042-060 to BAYADAP052A[ ]

Adapter Curb 4YCY4042-060 BAYADAP053A[ ]

Adapter Curb 4YCY4042-060 BAYADAP054A[ ]

12" Duct Shroud Covers Horizontal 4YCY4024-0607. ........................................................BAYCOVR112A[ ]

18" Duct Shroud Covers Horizontal 4YCY4024-060 7. .......................................................BAYCOVR118A[ ]

Extreme Condition Mounting Kit - All BAYCURB & BAYADAP .............................................BAYEXMK001A[ ]

Extreme Condition Mounting Kit - All BAYUTIL ....................................................................BAYEXMK002B[ ]

Extreme Condition Mounting Kit - All Slab Mounts ...............................................................BAYEXMK003A[ ]

Lifting Lug Kit ...........................................................................................................................BAYLlFT002B[ ]

NOTES:

1 Must use filter frame when economizer/fresh air kit is used.

2 Dry bulb control standard with economizer.

3 Ships knocked down.

4 Downflow only.

5 Low Ambient cooling requires crankcase heater (BAYCCHT----A).

6 It is the responsibility of the installing dealer to properly size the ductwork for each specific application.

7 BAYCOVR112,118A will not cover BAYSQRD002A applications

8 BAYACCDOR1A requires BAYFLTR101B &BAYACCDOR2A requires BAYFLTR201B. They are not backward compat-

ible to BAYFLTR101/201A.

‡ = A or B

4

General Data

MODEL

4YCY4024C1060A

4YCY4036C1070A

4YCY4030C1070A

RATED Volts/PH/Hz

208-230/1/60

208-230/1/60

208-230/1/60

Performance Cooling BTUH

23400

38000

30000

Indoor Airflow (CFM)

790

1210

900

Power Input (KW)

2.162

3.166

2.5

EER/SEER(BTU/Watt-Hr.)

12/14.0

12.0 / 14.2

12.0 / 14.0

Sound Power Rating [dB(A)]

68

69

71

Performance Heating

Input BTUH - 1st Stage (Natural Gas)

48000

56000

56000

Input BTUH - 2nd Stage (Natural Gas)

60000

70000

70000

AFUE

81

81

81

Temp. Rise — Min/Max (°F)

40 / 40

30 / 60

30 / 60

Orifice Qty / Drill Size (Natural Gas)

2 / #37

2 / #33

2 / #33

POWER CONN.—V/PH/HZ

208-230/1/60

208-230/1/60

208-230/1/60

Min. Brch. Cir. Ampacity

16.5

24.6

19.2

Fuse Size — Max. (amps)

25

40

30

Fuse Size — Recmd. (amps)

25

40

30

COMPRESSOR

RECIPROCATING

SCROLL

RECIPROCATING

Volts/Ph/Hz

208-230/1/60

208-230/1/60

200-230/1/60

R.L. Amps — L.R. Amps

8.3 / 57.8

15.4 / 83

11.1 / 63

OUTDOOR COIL — TYPE

SPINE-FIN

SPINE-FIN

SPINE-FIN

Rows/F.P.I.

2 / 24

2 / 24

2 / 24

Face Area (.)

13.32

15.49

13.32

Tube Size (in.)

3/8

3/8

3/8

INDOOR COIL — TYPE

PLATE FIN

PLATE FIN

PLATE FIN

Rows/F.P.I.

3 / 15

4 / 15

3 / 15

Face Area (.)

3.54

3.54

3.54

Tube Size (in.)

3/8

3/8

3/8

Refrigerant Control

EXPANSION VALVE

EXPANSION VALVE

EXPANSION VALVE

Drain Conn. Size (in.)

3/4 FEMALE NPT

3/4 FEMALE NPT

3/4 FEMALE NPT

OUTDOOR FAN — TYPE

PROPELLER

PROPELLER

PROPELLER

Dia. (in.)

23.4

23.4

23.4

Drive/No. Speeds

DIRECT / 1

DIRECT / 1

DIRECT / 1

*********.w.g.7

2570

3320

3260

Motor — HP/R.P.M.

1/12 / 810

1/5 / 830

1/6 / 830

Volts/Ph/Hz

208-230/1/60

208-230/1/60

208-230/1/60

F.L. Amps/L.R. Amps

0.54 / 0.95

1.1 / 1.9

1.0 / 1.7

INDOOR FAN — TYPE

CENTRIFUGAL

CENTRIFUGAL

CENTRIFUGAL

Dia x Width (in.)

10 X 10

10 X 10

10 X 10

Drive/No. Speeds

DIRECT / VARIABLE

DIRECT / VARIABLE

DIRECT / VARIABLE

*********.w.g.

SEE FAN PERFORMANCE TABLE

SEE FAN PERFORMANCE TABLE

SEE FAN PERFORMANCE TABLE

Motor — HP/R.P.M.

1/2 / VARIABLE

1/2 / VARIABLE

1/2 / VARIABLE

Volts/Ph/Hz

200-230/1/60

200-230/1/60

208-230/1/60

F.L. Amps/L.R. Amps

4.3 / 4.3

4.3 / 4.3

4.3 / 4.3

COMBUSTION FAN — TYPE

CENTRIFUGAL

CENTRIFUGAL

CENTRIFUGAL

Drive/No. Speeds

DIRECT / 2

DIRECT / 2

DIRECT / 2

Motor — HP/R.P.M.

1/20 / 3350/2600

1/20 / 3350/2600

1/20 / 3350/2600

Volts/Ph/Hz

208-230/1/60

208-230/1/60

208-230/1/60

FLA

0.34

0.34

0.34

FILTER / FURNISHED

NO

NO

NO

Type Recommended

THROWAWAY

THROWAWAY

THROWAWAY

Recmd. Face Area (sq. ft.)

4

4

4

REFRIGERANT

R410A

R410A

R410A

Charge (lbs.)

6.0

7.9

6.30

GAS PIPE SIZE (in.)

1/2

1/2

1/2

DIMENSIONS

H X W X L

H X W X L

H X W X L

Crated (in.)

45.86 / 44.5 / 52.03

47.86 / 44.5 / 52.03

45.86 / 44.5 / 52.03

WEIGHT

Shipping (lbs.) / Net (lbs.)

481 / 385

488 / 392

481 / 385

4YCY4036C1090A

208-230/1/60

38000

1210

3.166

12.0 / 14.2

69

72000

90000

81

40 / 70

3 / #37

208-230/1/60

24.6

40

40

SCROLL

208-230/1/60

15.4 / 83

SPINE-FIN

2 / 24

15.49

3/8

PLATE FIN

4 / 15

3.54

3/8

EXPANSION VALVE

3/4 FEMALE NPT

PROPELLER

23.4

DIRECT / 1

3320

1/5 / 830

208-230/1/60

1.1 / 1.9

CENTRIFUGAL

10 X 10

DIRECT / VARIABLE

SEE FAN PERFORMANCE TABLE

1/2 / VARIABLE

200-230/1/60

4.3 / 4.3

CENTRIFUGAL

DIRECT / 2

1/20 / 3350/2600

208-230/1/60

0.34

NO

THROWAWAY

4

R410A

7.9

1/2

H X W X L

47.86 / 44.5 / 52.03

493 / 397

1 Certified in accordance with the Unitary Air-Conditioner Equipment certification program, which is based on AHRI Standard 210/240. Sound

Power values are not adjusted for AHRI 270-95 tonal corrections.

2 All models are certified to UL 1995. Ratings shown are for elevations up to 2000 ft. For higher elevations reduce ratings at a rate of 4% per

1000 ft. elevation.

3 Convertible to LPG.

4 This value is approximate. For more precise value, see Unit Nameplate.

5 Based on U.S. Government Standard Tests.

6 Filters must be installed in return air stream. Square footages listed are based on 300 face velocity. If permanent filters are used size

per manufacturer's recommendation with a clean resistance of 0.05" W.C.

7 Standard Air - Dry Coil - Outdoor.

5

General Data

MODEL

4YCY4036B3075A

RATED Volts/PH/Hz

208-230/3/60

Performance Cooling BTUH

36000

Indoor Airflow (CFM)

1210

Power Input (KW)

3.284

EER/SEER(BTU/Watt-Hr.)

11.6 / 14.2

Sound Power Rating [dB(A)]

69

Performance Heating

Input BTUH - 1st Stage (Natural Gas)

56250

Input BTUH - 2nd Stage (Natural Gas)

75000

AFUE

80

Temp. Rise — Min/Max (°F)

30 / 60

Orifice Qty / Drill Size (Natural Gas)

2 / #33

POWER CONN.—V/PH/HZ

208-230/3/60

Min. Brch. Cir. Ampacity

19.8

Fuse Size — Max. (amps)

30

Fuse Size — Recmd. (amps)

30

COMPRESSOR

SCROLL

Volts/Ph/Hz

208-230/3/60

R.L. Amps — L.R. Amps

11.5 / 77

OUTDOOR COIL — TYPE

SPINE-FIN

Rows/F.P.I.

2 / 24

Face Area (.)

15.49

Tube Size (in.)

3/8

INDOOR COIL — TYPE

PLATE FIN

Rows/F.P.I.

4 / 15

Face Area (.)

3.54

Tube Size (in.)

3/8

Refrigerant Control

EXPANSION VALVE

Drain Conn. Size (in.)

3/4 FEMALE NPT

OUTDOOR FAN — TYPE

PROPELLER

Dia. (in.)

23.4

Drive/No. Speeds

DIRECT / 1

*********.w.g.7

3280

Motor — HP/R.P.M.

1/5 / 830

Volts/Ph/Hz

208-230/1/60

F.L. Amps/L.R. Amps

1.1 / 1.9

INDOOR FAN — TYPE

CENTRIFUGAL

Dia x Width (in.)

10 X 10

Drive/No. Speeds

DIRECT / VARIABLE

*********.w.g.

SEE FAN PERFORMANCE TABLE

Motor — HP/R.P.M.

1/2 / VARIABLE

Volts/Ph/Hz

200-230/1/60

F.L. Amps/L.R. Amps

4.3 / 4.3

COMBUSTION FAN — TYPE

CENTRIFUGAL

Drive/No. Speeds

DIRECT / 2

Motor — HP/R.P.M.

1/45 / 2800/1500

Volts/Ph/Hz

208-230/1/60

FLA

0.34

FILTER / FURNISHED

NO

Type Recommended

THROWAWAY

Recmd. Face Area (sq. ft.)

4

REFRIGERANT

R410A

Charge (lbs.)

6.75

GAS PIPE SIZE (in.)

1/2

DIMENSIONS

H X W X L

Crated (in.)

47.86 / 44.5 / 52.03

WEIGHT

Shipping (lbs.) / Net (lbs.)

488 / 392

4YCY4036A3096A

208-230/3/60

36000

1210

3.284

11.6 / 14.2

69

72000

96000

80

40 / 70

3 / #37

208-230/3/60

19.8

30

30

SCROLL

208-230/3/60

11.5 / 77

SPINE-FIN

2 / 24

15.49

3/8

PLATE FIN

4 / 15

3.54

3/8

EXPANSION VALVE

3/4 FEMALE NPT

PROPELLER

23.4

DIRECT / 1

3280

1/5 / 830

208-230/1/60

1.1 / 1.9

CENTRIFUGAL

10 X 10

DIRECT / VARIABLE

SEE FAN PERFORMANCE TABLE

1/2 / VARIABLE

200-230/1/60

4.3 / 4.3

CENTRIFUGAL

DIRECT / 2

1/45 / 2800/1500

208-230/1/60

0.34

NO

THROWAWAY

4

R410A

6.75

1/2

H X W X L

47.86 / 44.5 / 52.03

493 / 397

4YCY4042C1090A

208-230/1/60

42000

1370

3.5

12.0 / 14.25

74

72000

90000

81

30 / 60

3 / #37

208-230/1/60

31.5

50

50

SCROLL

208-230/1/60

18.6 / 105

SPINE-FIN

2 / 24

18.01

3/8

PLATE FIN

3 / 15

5

3/8

EXPANSION VALVE

3/4 FEMALE NPT

PROPELLER

28.2

DIRECT / 1

4480

1/4 / 825

208-230/1/60

1.5 / 3.4

CENTRIFUGAL

11 X 10

DIRECT / VARIABLE

SEE FAN PERFORMANCE TABLE

3/4 / VARIABLE

208-230/1/60

6.8 / 6.8

CENTRIFUGAL

DIRECT / 2

1/20 / 3350/2600

208-230/1/60

0.34

NO

THROWAWAY

5.3

R410A

6.8125

1/2

H X W X L

47.86 / 47.4 / 61.75

653 / 525

1 Certified in accordance with the Unitary Air-Conditioner Equipment certification program, which is based on AHRI Standard 210/240. Sound

Power values are not adjusted for AHRI 270-95 tonal corrections.

2 All models are certified to UL 1995. Ratings shown are for elevations up to 2000 ft. For higher elevations reduce ratings at a rate of 4% per

1000 ft. elevation.

3 Convertible to LPG.

4 This value is approximate. For more precise value, see Unit Nameplate.

5 Based on U.S. Government Standard Tests.

6 Filters must be installed in return air stream. Square footages listed are based on 300 face velocity. If permanent filters are used size

per manufacturer's recommendation with a clean resistance of 0.05" W.C.

7 Standard Air - Dry Coil - Outdoor.

6

General Data

MODEL

RATED Volts/PH/Hz

Performance Cooling BTUH

Indoor Airflow (CFM)

Power Input (KW)

EER/SEER(BTU/Watt-Hr.)

Sound Power Rating [dB(A)]

Performance Heating

Input BTUH - 1st Stage (Natural Gas)

Input BTUH - 2nd Stage (Natural Gas)

AFUE

Temp. Rise — Min/Max (°F)

Orifice Qty / Drill Size (Natural Gas)

POWER CONN.—V/PH/HZ

Min. Brch. Cir. Ampacity

Fuse Size — Max. (amps)

Fuse Size — Recmd. (amps)

COMPRESSOR

Volts/Ph/Hz

R.L. Amps — L.R. Amps

OUTDOOR COIL — TYPE

Rows/F.P.I.

Face Area (.)

Tube Size (in.)

INDOOR COIL — TYPE

Rows/F.P.I.

Face Area (.)

Tube Size (in.)

Refrigerant Control

Drain Conn. Size (in.)

OUTDOOR FAN — TYPE

Dia. (in.)

Drive/No. Speeds

*********.w.g.7

Motor — HP/R.P.M.

Volts/Ph/Hz

F.L. Amps/L.R. Amps

INDOOR FAN — TYPE

Dia x Width (in.)

Drive/No. Speeds

*********.w.g.

Motor — HP/R.P.M.

Volts/Ph/Hz

F.L. Amps/L.R. Amps

COMBUSTION FAN — TYPE

Drive/No. Speeds

Motor — HP/R.P.M.

Volts/Ph/Hz

FLA

FILTER / FURNISHED

Type Recommended

Recmd. Face Area (sq. ft.)

REFRIGERANT

Charge (lbs.)

GAS PIPE SIZE (in.)

DIMENSIONS

Crated (in.)

WEIGHT

Shipping (lbs.) / Net (lbs.)

4YCY4048C1090A

208-230/1/60

48500

1605

4.041

12 / 14.2

73

72000

90000

81

30 / 60

3 / #37

208-230/1/60

35.4

50

50

SCROLL

208-230/1/60

21.8 / 117

SPINE-FIN

2 / 24

18.01

3/8

PLATE FIN

3 / 15

5.0

3/8

EXPANSION VALVE

3/4 FEMALE NPT

PROPELLER

28.2

DIRECT / 1

4470

1/4 / 825

208-230/1/60

1.4 / 3.5

CENTRIFUGAL

11 X 10

DIRECT / VARIABLE

SEE FAN PERFORMANCE TABLE

3/4 / VARIABLE

200-230/1/60

6.8 / 6.8

CENTRIFUGAL

DIRECT / 2

1/20 / 3350/2600

208-230/1/60

0.34

NO

THROWAWAY

5.3

R410A

8.0

1/2

H X W X L

47.86 / 47.4 / 61.75

669 / 541

4YCY4048C1115A

208-230/1/60

48500

1605

4.041

12 / 14.2

73

90000

115000

81

40 / 70

3 / #32

208-230/1/60

35.4

50

50

SCROLL

208-230/1/60

21.8 / 117

SPINE-FIN

2 / 24

18.01

3/8

PLATE FIN

3 / 15

5.0

3/8

EXPANSION VALVE

3/4 FEMALE NPT

PROPELLER

28.2

DIRECT / 1

4470

1/4 / 825

208-230/1/60

1.4 / 3.37

CENTRIFUGAL

11 X 10

DIRECT / VARIABLE

SEE FAN PERFORMANCE TABLE

3/4 / VARIABLE

200-230/1/60

6.8 / 6.8

CENTRIFUGAL

DIRECT / 2

1/20 / 3350/2600

208-230/1/60

0.34

NO

THROWAWAY

5.3

R410A

8.0

1/2

H X W X L

47.86 / 47.4 / 61.75

675 / 547

4YCY4048B3096A

208-230/3/60

48000

1605

4.034

11.9 / 14.2

73

72000

96000

80

30 / 60

3 / #37

208-230/3/60

26.4

40

40

SCROLL

208-230/3/60

14.6 / 91

SPINE-FIN

2 / 24

18.01

3/8

PLATE FIN

3 / 15

5.0

3/8

EXPANSION VALVE

3/4 FEMALE NPT

PROPELLER

28.2

DIRECT / 1

4470

1/4 / 825

208-230/1/60

1.4 / 3.5

CENTRIFUGAL

11 X 10

DIRECT / VARIABLE

SEE FAN PERFORMANCE TABLE

3/4 / VARIABLE

200-230/1/60

6.8 / 6.8

CENTRIFUGAL

DIRECT / 2

1/45 / 2800/1500

208-230/1/60

0.34

NO

THROWAWAY

5.3

R410A

8.2

1/2

H X W X L

47.86 / 47.4 / 61.75

653 / 525

1 Certified in accordance with the Unitary Air-Conditioner Equipment certification program, which is based on AHRI Standard 210/240. Sound

Power values are not adjusted for AHRI 270-95 tonal corrections.

2 All models are certified to UL 1995. Ratings shown are for elevations up to 2000 ft. For higher elevations reduce ratings at a rate of 4% per

1000 ft. elevation.

3 Convertible to LPG.

4 This value is approximate. For more precise value, see Unit Nameplate.

5 Based on U.S. Government Standard Tests.

6 Filters must be installed in return air stream. Square footages listed are based on 300 face velocity. If permanent filters are used size

per manufacturer's recommendation with a clean resistance of 0.05" W.C.

7 Standard Air - Dry Coil - Outdoor.

7

General Data

MODEL

RATED Volts/PH/Hz

Performance Cooling BTUH

Indoor Airflow (CFM)

Power Input (KW)

EER/SEER(BTU/Watt-Hr.)

Sound Power Rating [dB(A)]

Performance Heating

Input BTUH - 1st Stage (Natural Gas)

Input BTUH - 2nd Stage (Natural Gas)

AFUE

Temp. Rise — Min/Max (°F)

Orifice Qty / Drill Size (Natural Gas)

POWER CONN.—V/PH/HZ

Min. Brch. Cir. Ampacity

Fuse Size — Max. (amps)

Fuse Size — Recmd. (amps)

COMPRESSOR

Volts/Ph/Hz

R.L. Amps — L.R. Amps

OUTDOOR COIL — TYPE

Rows/F.P.I.

Face Area (.)

Tube Size (in.)

INDOOR COIL — TYPE

Rows/F.P.I.

Face Area (.)

Tube Size (in.)

Refrigerant Control

Drain Conn. Size (in.)

OUTDOOR FAN — TYPE

Dia. (in.)

Drive/No. Speeds

*********.w.g.7

Motor — HP/R.P.M.

Volts/Ph/Hz

F.L. Amps/L.R. Amps

INDOOR FAN — TYPE

Dia x Width (in.)

Drive/No. Speeds

*********.w.g.

Motor — HP/R.P.M.

Volts/Ph/Hz

F.L. Amps/L.R. Amps

COMBUSTION FAN — TYPE

Drive/No. Speeds

Motor — HP/R.P.M.

Volts/Ph/Hz

FLA

FILTER / FURNISHED

Type Recommended

Recmd. Face Area (sq. ft.)

REFRIGERANT

Charge (lbs.)

GAS PIPE SIZE (in.)

DIMENSIONS

Crated (in.)

WEIGHT

Shipping (lbs.) / Net (lbs.)

4YCY4048B3120A

208-230/3/60

48000

1605

4.034

11.9 / 14.2

73

90000

120000

80

40 / 70

3 / #32

208-230/3/60

26.4

40

40

SCROLL

208-230/3/60

14.6 / 91

SPINE-FIN

2 / 24

18.01

3/8

PLATE FIN

3 / 15

5.0

3/8

EXPANSION VALVE

3/4 FEMALE NPT

PROPELLER

28.2

DIRECT / 1

4470

1/4 / 825

208-230/1/60

1.4 / 3.37

CENTRIFUGAL

11 X 10

DIRECT / VARIABLE

SEE FAN PERFORMANCE TABLE

3/4 / VARIABLE

200-230/1/60

6.8 / 6.8

CENTRIFUGAL

DIRECT / 2

1/45 / 2800/1500

208-230/1/60

0.34

NO

THROWAWAY

5.3

R410A

8.2

1/2

H X W X L

47.86 / 47.4 / 61.75

659 / 531

4YCY4060C1115A

208-230/1/60

58500

1800

5.478

12/14.0

76

90000

115000

81

30 / 60

3 / #32

208-230/1/60

42.3

60

60

SCROLL

208-230/1/60

26.9 / 145

SPINE-FIN

2 / 24

23.57

3/8

PLATE FIN

4 / 15

5.0

3/8

EXPANSION VALVE

3/4 FEMALE NPT

PROPELLER

28.2

DIRECT / 1

5730

1/3 / 830

208-230/1/60

1.7 / 3.5

CENTRIFUGAL

11 X 10

DIRECT / VARIABLE

SEE FAN PERFORMANCE TABLE

1 / VARIABLE

208-230/1/60

6.9 / 6.9

CENTRIFUGAL

DIRECT / 2

1/20 / 3350/2600

208-230/1/60

0.34

NO

THROWAWAY

5.3

R410A

9.75

1/2

H X W X L

51.86 / 47.4 / 61.75

676 / 548

4YCY4060A3120B

208-230/3/60

58500

1800

5.478

12/14.0

76

90000

120000

80

30 / 60

3 / #32

208-230/3/60

30.6

45

45

SCROLL

208-230/3/60

17.6 / 123

SPINE-FIN

2 / 24

23.57

3/8

PLATE FIN

4 / 15

5.0

3/8

EXPANSION VALVE

3/4 FEMALE NPT

PROPELLER

28.2

DIRECT / 1

5730

1/3 / 830

208-230/1/60

1.7 / 3.5

CENTRIFUGAL

11 X 10

DIRECT / VARIABLE

SEE FAN PERFORMANCE TABLE

1 / VARIABLE

208-230/1/60

6.9 / 6.9

CENTRIFUGAL

DIRECT / 2

1/45 / 2800/1500

208-230/1/60

0.34

NO

THROWAWAY

6.7

R410A

9.75

1/2

H X W X L

51.86 / 47.4 / 61.75

676 / 548

1 Certified in accordance with the Unitary Air-Conditioner Equipment certification program, which is based on AHRI Standard 210/240. Sound

Power values are not adjusted for AHRI 270-95 tonal corrections.

2 All models are certified to UL 1995. Ratings shown are for elevations up to 2000 ft. For higher elevations reduce ratings at a rate of 4% per

1000 ft. elevation.

3 Convertible to LPG.

4 This value is approximate. For more precise value, see Unit Nameplate.

5 Based on U.S. Government Standard Tests.

6 Filters must be installed in return air stream. Square footages listed are based on 300 face velocity. If permanent filters are used size

per manufacturer's recommendation with a clean resistance of 0.05" W.C.

7 Standard Air - Dry Coil - Outdoor.

8

Indoor Fan Performance 4YCY4024

Horizontal Airflow

4YCY4024-HOR

Motor Speed

LOW

MED*

HIGH

Indoor Blower Performance

External Static Pressure (in. wg)

00.10.20.30.40.50.60.7

Watts52668911514

CFM731719700679

Watts-94123254

CFM-793893780

Watts--1243284

CFM--8778929

0.8

229

662

267

778

342

869

0.9

259

659

290

799

426

863

1

300

682

320

800

551

877

Down Airflow

4YCY4024-DOWN

Motor Speed

LOW

MED*

HIGH

External Static Pressure (in. wg)

00.10.20.30.40.50.60.7

Watts357188204

CFM695729734728721715705679

Watts7987106232

CFM846813803794

Watts86113242275

CFM884877895886

0.8

240

675

264

800

319

898

0.9

270

680

306

820

345

910

1

320

685

364

810

385

900

Indoor Fan Performance 4YCY4030

Horizontal Airflow

4YCY4030-HOR

Motor Speed

350 CFM

400 CFM*

450 CFM

Watts

CFM

Watts

CFM

Watts

CFM

-

-

-

-

-

-

0

113

880

146

996

195

1122

0.1

148

905

184

1009

233

1132

External Static Pressure (in. wg)

0.20.30.40.50.60.7

176

917

215

1013

267

1134

203

918

243

1012

303

1136

0.80.9

267

979

312

991

-

-

1

-

-

-

-

-

-

233263291309306

9139

2723

197994

34-

71039-

Down Airflow

4YCY4030-DOWN

Motor Speed

Watts

350 CFM

CFM

Watts

400 CFM*

CFM

Watts

450 CFM

CFM

0

-

-

-

-

-

-

112

871

152

990

191

1090

0.1

147

894

185

995

227

1099

External Static Pressure (in. wg)

0.20.30.40.50.60.7

172

898

211

992

258

1095

198

893

238

984

289

1091

227259288303

884874864851

269303333349

974964955946

321355392432

1011

0.8

286

828

334

937

-

-

0.9

217

788

271

925

-

-

1

-

-

-

-

-

-

*Factory Default Setting

9

Indoor Blower Performance

Indoor Fan Performance 4YCY4036

Horizontal Airflow

4YCY4036-HOR

Motor Speed

LOW

MED*

HIGH

External Static Pressure (in. wg)

00.10.20.30.40.50.60.70.80.91

Watts62562853525

CFM10421033

Watts179236455

CFM511691144

Watts3435469502533563--

CFM49--

Down Airflow

4YCY4036-DOWN

Motor Speed

LOW

MED*

HIGH

External Static Pressure (in. wg)

00.10.20.30.40.50.60.70.80.91

Watts

CFM175990

Watts2252532833449484522575

CFM7711651150

Watts339357396571669--

CFM720--

Indoor Fan Performance 4YCY4042

Horizontal Airflow

4YCY4042-HOR

Motor Speed

0

Watts

CFM

Watts

CFM

Watts

CFM

0.1

External Static Pressure (in. wg)

0.20.30.40.50.60.70.80.91

350 CFM

400 CFM*

450 CFM

-

-

-

-

-

-

160

1206

231

1389

326

1582

185

1211

261

1398

362

1592

214

1213

292

1405

393

1593

245

1215

325

1409

421

1587

277

1215

359

1410

450

1577

308

1214

394

1408

482

1566

339

1212

431

1403

517

1557

368

1208

467

1399

556

1553

396

1201

503

1396

597

1556

423

1190

536

1399

-

-

Down Airflow

4YCY4042-DOWN

Motor Speed

0

Watts

CFM

Watts

CFM

Watts

CFM

0.1

External Static Pressure (in. wg)

0.20.30.40.50.60.70.80.91

350 CFM

400 CFM*

450 CFM

-

-

-

-

-

-

176

1207

253

1405

367

1599

203

1214

290

1411

379

1577

232

1217

323

1413

409

1570

262

1216

355

1412

446

1569

294

1213

386

1407

485

1566

325

1208

420

1399

522

1560

357

1201

455

1389

556

1550

388

1193

491

1377

591

1537

417

1185

526

1366

633

1528

443

1177

558

1357

-

-

*Factory Default Setting

10

Indoor Blower Performance

Indoor Fan Performance 4YCY4048

Horizontal Airflow

4YCY4048-HOR

Motor Speed

LOW

MED*

HIGH

External Static Pressure (in. wg)

00.10.20.30.40.50.60.70.80.91

Watts229487538

CFM14771392

Watts268344848352

CFM915681550

Watts37843264-

CFM871807-

Down Airflow

4YCY4048-DOWN

Motor Speed

LOW

MED*

HIGH

External Static Pressure (in. wg)

00.10.20.30.40.50.60.70.80.91

Watts6478505545

CFM3014101400

Watts2533323794

CFM4816181624

Watts3644643693739764785-

CFM601825-

Indoor Fan Performance 4YCY4060

Horizontal Airflow

4YCY4060-HOR

Motor Speed

LOW

MED*

External Static Pressure (in. wg)

00.10.20.30.40.50.60.70.80.9

Watts394427464568--

CFM9117671756--

Watts6956426698939661108

CFM2000

1

-

-

-

-

Down Airflow

4YCY4060-DOWN

Motor Speed

LOW

MED*

External Static Pressure (in. wg)

00.10.20.30.40.50.60.70.80.9

Watts4434607642680--

CFM6216981692--

Watts749866892894872835

CFM29779

1

-

-

-

-

*Factory Default Setting

11

Indoor Blower Performance

Heating Airflow, horizontal or downflow from .2 to .6” wg.

4YCY4024C1060

Switch SettingsSelectionNominal Airflow

Low StageHigh Stage

7-OFF8-OFFA600850

7-ON8-OFFB625900

7-OFF8-ONC650925

7-ON8-OND700975

4YCY4030

Switch SettingsSelectionNominal Airflow

Low StageHigh Stage

7-OFF8-OFFA7251000

7-ON8-OFFB7751075

7-OFF8-ONC8501150

7-ON8-OND9251250

4YCY4036C *070

Switch SettingsSelectionNominal Airflow

Low StageHigh Stage

7-OFF8-OFFA7251000

7-ON8-OFFB7751075

7-OFF8-ONC8501150

7-ON8-OND9251250

* can be 1 or 3

4YCY4036C *090

Switch SettingsSelectionNominal Airflow

Low StageHigh Stage

7-OFF8-OFFA8251100

7-ON8-OFFB8751175

7-OFF8-ONC9501275

7-ON8-OND10251375

* can be 1 or 3

12

4YCY4042

Switch SettingsSelectionNominal Airflow

Low StageHigh Stage

7-OFF8-OFFA10751375

7-ON8-OFFB11001450

7-OFF8-ONC11501500

7-ON8-OND12001575

4YCY4048C*090

Switch Settings

Selection

Nominal Airflow

Low StageHigh Stage

7-OFF8-OFFA10751375

7-ON8-OFFB11001450

7-OFF8-ONC11501500

7-ON8-OND12001575

* can be 1 or 3

4YCY4048C*115

Switch Settings

Selection

Nominal Airflow

Low StageHigh Stage

7-OFF8-OFFA10501500

7-ON8-OFFB11001575

7-OFF8-ONC11501625

7-ON8-OND12001700

* can be 1 or 3

4YCY4060

Switch SettingsSelection

Nominal Airflow

Low StageHigh Stage

7-OFF8-OFFA13751800

7-ON8-OFFB14501900

7-OFF8-ONC15251975

7-ON8-OND15752075

Typical Field Wiring

UNIT CONTROL BOX

B

G

Y

W1

W2

R

COMMON

FAN

(GR)

COMPRESSOR

HEAT FIRST STAGE

(WH)

HEAT SECOND STAGE

(WH)

24V

GROUND

WIRE

1 PH

POWER

3 PH

POWER

UNIT

NOTE 1

B

G

Y

W1

W2

R

COMMON

FAN

(GR)

COMPRESSOR

HEAT FIRST STAGE

(WH)

HEAT SECOND STAGE

(WH)

24V

B

G

(GR)

Y

W1

(WH)

W2

(WH)

R

C 757192i2

13

Typical Wiring

14

Typical Wiring

15

Optional Equipment

BAYCURB050A Full Perimeter Roof Mounting Curb for *****018-036

17 7/8

46 3/8

3

3 5/8

19 1/2

2 3/16

15

38 7/8

14

1 1/2

19 1/2

The drawings on this page are prepared by the manu-

facturer in order to provide detail regarding job layout

only. These drawings are not intended to be used as a

basis to construct, build or modify the items depicted

in the drawings. The manufacturer is not responsible for

the unauthorized use of these drawings and expressly

disclaims any liability for damages resulting from such

unauthorized use.

43 3/8

35 7/8

16

Optional Equipment

BAYCURB051A Full Perimeter Roof Mounting Curb for *****042-060

15 7/8

56 1/8

3

1 1/2

19 1/2

20

41 7/8

14

The drawings on this page are prepared by the manu-

facturer in order to provide detail regarding job layout

only. These drawings are not intended to be used as a

basis to construct, build or modify the items depicted

in the drawings. The manufacturer is not responsible for

the unauthorized use of these drawings and expressly

disclaims any liability for damages resulting from such

unauthorized use.

10 7/8

4 3/4

19 1/2

38 7/8

53 1/8

17

Optional Equipment

BAYFLTR101, 201B, 1" - 2" Filter Rack

(Mounts in Filter/Coil Section)

Filter

BAYACCDOR1A & BAYACCDOR2A Hinged Filter Access Door

Replaces Filter/Coil Access Panel

The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not

intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer is not responsible for the

unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use.

18

Optional Equipment

BAYECON101,102A Down Discharge Economizer and Rain Hood

(Mounts Over Horizontal Return Air Opening)

HVAC Unit

A

Economizer

rain hood

Outside air

dampers

Return air

dampers

Mist elimi-

nator

Relief

damper

Roofcurb

Required

filter kit, order

separately

Economizer

BAYECON101A

BAYECON102A

Unit Application Models

4TC*,WC*,YC*,DC*

*018-036

4TC*,WC*,YC*, DC*

*042-060

A

20.125"

24.375"

Return

Duct

BAYECON200,201A Horizontal Economizer and Rain Hood

The drawings on this page are

prepared by the manufacturer in

order to provide detail regarding

job layout only. These drawings

are not intended to be used as a

basis to construct, build or modify

the items depicted in the draw-

ings. The manufacturer is not re-

sponsible for the unauthorized use

of these drawings and expressly

disclaims any liability for damages

resulting from such unauthorized

use.

Economizer

A

C

B

D

Gaskets (2)

Duct

E

Rain Hood

Mixed Air Sensor

Economizer

BAYECON200AA

BAYECON201AA

A

22"

26"

B

20"

22-21/32"

C

16-7/8"

19"

D

15-11/16"

17-11/16"

E

11-11/16"

14-11/16"

F

15"

21-3/8"

19

Optional Equipment

BAYOSAH001,002A, 25% Outside Air Damper

(Replaces Filter/Coil Access Panel)

The drawings on this page are prepared by

the manufacturer in order to provide detail

regarding job layout only. These drawings

are not intended to be used as a basis to

construct, build or modify the items de-

picted in the drawings. The manufacturer is

not responsible for the unauthorized use of

these drawings and expressly disclaims any

liability for damages resulting from such

unauthorized use.

A

FULLY

OPEN

D

C

2/3

1/3

B

FULLY

CLOSED

Manual Fresh Air

Model

Unit Application

Models

4YC,WC3018-036

4TC*3018-036,

4W/T/Y/DCY4024-036,

4W/Y/DCZ6036

4YC,WC3042-060,

4TC*3042-060,

4W/T/Y/DCY4042-060,

4W/Y/DCZ6048-060

ABCD

BAYOSAH00122 7/16""20 11/16""12 3/8""9 3/16""

BAYOSAH00225 3/16""20 11/16""12 3/8""9 3/16""

BAYDMPR101,102A, 25% Motorized Outside Air Damper

(Mounts Over Horizontal Return AIr Opening)

A

C

B

E

D

Unit Application Models

4YC,WC3018-036

4TC*3018-036,

4W/T/Y/DCY4024-036,

4W/Y/DCZ6036

4YC,WC3042-060,

4TC*3042-060,

4W/T/Y/DCY4042-060,

4W/Y/DCZ6048-060

ABCDE

BAYDMPR101A

15 13/16""11 13/16""10 1/4""11 1/2""12 1/4""

BAYDMPR102A

18 3/16""15 1/8""10 1/4""11 1/2""12 1/4""

20

2024年10月29日发(作者:环之槐)

22-1797-16-EN

Product Data

4YCY4024 through 4YCY4060

Packaged Convertible Gas/Electric

14 SEER

2 - 5 Ton, 60 - 120 MBTU

R-410A

©

2014 Trane

Pub. No. 22-1797-16-EN

It's Hard to Stop a Trane.

Packaged Convertible Gas/Electric System

Trane offers a complete family of packaged gas/electric heating and cooling systems,

designed to give you the unbeatable combination of energy efficiency and lower operat-

ing costs. In warm weather, the packaged gas/electric system functions as an all-electric,

high efficiency air conditioner. In cold weather, it operates as a natural gas or propane gas

furnace, offering you the best of both energy worlds.

Introducing the new TRANE Packaged Convertible Gas/Elec-

tric System.

Single Packaged Convertible Gas/

Electric Systems are easy and ver-

satile to install. Because cooling and

heating functions are all contained in a

single cabinet, a Trane single packaged

convertible gas/electric system is easy to

install and service. It can be flush mount-

ed beside your home at ground level

or placed on the roof for horizontal or

downflow installation. When connected to

an optional Trane thermostat control, and

air distribution ducts, you have a highly

efficient, total home comfort system.

Single Packaged Convertible Gas/

Electric Systems are unmatched in

quality and reliability. All major com-

ponents on these products, including

the compressor, have been designed

and manufactured for maximum service.

Every Climatuff

®

compressor is de-

signed and manufactured to exacting

specifications. Each design is life tested

in extreme environments to ensure

reliable and long lasting operation in

normal applications. Each compressor

has internal motor protection for added

reliability.

2

3

Contents

Optional Equipment Listing 4

General Data 5

Performance Data

Indoor Fan 9

Typical Wiring 13

Optional Equipment 16

Dimensional Data 21

Mechanical Specifications 27

Optional Equipment Listing

OPTIONAL EQUIPMENT FOR PACKAGED UNITS (check mark [3] indicates accessories included)

Hinged Filter Access Door (4YCY4024-036) 8 ................................................................BAYACCDOR1A[ ]

Hinged Filter Access Door (4YCY4042-060) 8 ..............................................................BAYACCDOR2A[ ]

Roof Curb Full Perimeter (4YCY4024-36) 3 .....................................................................BAYCURB050A[ ]

Roof Curb Full Perimeter (4YCY4042-60) 3 .....................................................................BAYCURB051A[ ]

Roof Curb Utility Extension Kit (BAYCURB050A)....................................................................BAYUTIL101B[ ]

Roof Curb Utility Extension Kit (BAYCURB051A)....................................................................BAYUTIL102B[ ]

0-25% Manual Fresh Air Damper (4YCY4024-36) 1. ..........................................................BAYOSAH001A[ ]

0-25% Manual Fresh Air Damper (4YCY4042-60) 1. ..........................................................BAYOSAH002A[ ]

Motorized Fresh Air Damper (4YCY4024-36) 1. ...............................................................BAYDMPR101A[ ]

Motorized Fresh Air Damper (4YCY4042-60) 1. ................................................................BAYDMPR102A[ ]

16" Round Duct Adapter (2 per box) (4YCY4024-36) 6 ....................................................BAYSQRD001A[ ]

18" Round Duct Adapter (2 per box) (4YCY4024-60) 6 ....................................................BAYSQRD002A[ ]

0-100% Mod Economizer w/Baro. Relief (4YCY4024-36) 124 .......................................BAYECON101B[ ]

0-100% Mod. Economizer w/Baro. Relief (4YCY4042-60) 124. ......................................BAYECON102B[ ]

0-100% Horizontal Economizer (4YCY4024-36) 12 . .......................................................BAYECON200A[ ]

0-100% Horizontal Economizer (4YCY4042-60) 12 . .......................................................BAYECON201A[ ]

Enthalpy Control for Economizer (solid state). ......................................................................BAYENTH001A[ ]

Remote Potentiometer (All-BAYECON***A) .............................................................................BAYSTAT023[ ]

1"-2" Filter Frame (4YCY4024-36) (20 x 25 filter not included) 1. ............BAYFLTR101B[ ]

1"-2" Filter Frame (4YCY4042-60) (20 x 20 & 20 x 18 filter not included) 1. .......BAYFLTR201B[ ]

LP Conversion Kit (All 40K, 120K Models) ...........................................................................BAYLPKT100A[ ]

LP Conversion Kit (All 64K, 96K Models) .............................................................................BAYLPKT101A[ ]

LP Conversion Kit (All 75K Models).......................................................................................BAYLPKT102A[ ]

Head Pressure Control (Low Ambient Cool) (208/240v) Kit 5. ...........................................BAYLOAM105A[ ]

Quick Start Kit (4YCY4-‡1) ..................................................................................................BAYQSKT301A[ ]

Crankcase Heater Recip (4YCY4024-030) (230v) 5. ..........................................................BAYCCHT101A[ ]

Crankcase Heater Scroll (4YCY4042-060‡1/3)(230v) 5. ....................................................BAYCCHT102A[ ]

Crankcase Heater Scroll (4YCY4036)(230v) 5. ..................................................................BAYCCHT103A[ ]

Adapter Curb 4YCY4024-036 to BAYADAP050A[ ]

Adapter Curb 4YCY4024-036 BAYADAP051A[ ]

Adapter Curb 4YCY4042-060 to BAYADAP052A[ ]

Adapter Curb 4YCY4042-060 BAYADAP053A[ ]

Adapter Curb 4YCY4042-060 BAYADAP054A[ ]

12" Duct Shroud Covers Horizontal 4YCY4024-0607. ........................................................BAYCOVR112A[ ]

18" Duct Shroud Covers Horizontal 4YCY4024-060 7. .......................................................BAYCOVR118A[ ]

Extreme Condition Mounting Kit - All BAYCURB & BAYADAP .............................................BAYEXMK001A[ ]

Extreme Condition Mounting Kit - All BAYUTIL ....................................................................BAYEXMK002B[ ]

Extreme Condition Mounting Kit - All Slab Mounts ...............................................................BAYEXMK003A[ ]

Lifting Lug Kit ...........................................................................................................................BAYLlFT002B[ ]

NOTES:

1 Must use filter frame when economizer/fresh air kit is used.

2 Dry bulb control standard with economizer.

3 Ships knocked down.

4 Downflow only.

5 Low Ambient cooling requires crankcase heater (BAYCCHT----A).

6 It is the responsibility of the installing dealer to properly size the ductwork for each specific application.

7 BAYCOVR112,118A will not cover BAYSQRD002A applications

8 BAYACCDOR1A requires BAYFLTR101B &BAYACCDOR2A requires BAYFLTR201B. They are not backward compat-

ible to BAYFLTR101/201A.

‡ = A or B

4

General Data

MODEL

4YCY4024C1060A

4YCY4036C1070A

4YCY4030C1070A

RATED Volts/PH/Hz

208-230/1/60

208-230/1/60

208-230/1/60

Performance Cooling BTUH

23400

38000

30000

Indoor Airflow (CFM)

790

1210

900

Power Input (KW)

2.162

3.166

2.5

EER/SEER(BTU/Watt-Hr.)

12/14.0

12.0 / 14.2

12.0 / 14.0

Sound Power Rating [dB(A)]

68

69

71

Performance Heating

Input BTUH - 1st Stage (Natural Gas)

48000

56000

56000

Input BTUH - 2nd Stage (Natural Gas)

60000

70000

70000

AFUE

81

81

81

Temp. Rise — Min/Max (°F)

40 / 40

30 / 60

30 / 60

Orifice Qty / Drill Size (Natural Gas)

2 / #37

2 / #33

2 / #33

POWER CONN.—V/PH/HZ

208-230/1/60

208-230/1/60

208-230/1/60

Min. Brch. Cir. Ampacity

16.5

24.6

19.2

Fuse Size — Max. (amps)

25

40

30

Fuse Size — Recmd. (amps)

25

40

30

COMPRESSOR

RECIPROCATING

SCROLL

RECIPROCATING

Volts/Ph/Hz

208-230/1/60

208-230/1/60

200-230/1/60

R.L. Amps — L.R. Amps

8.3 / 57.8

15.4 / 83

11.1 / 63

OUTDOOR COIL — TYPE

SPINE-FIN

SPINE-FIN

SPINE-FIN

Rows/F.P.I.

2 / 24

2 / 24

2 / 24

Face Area (.)

13.32

15.49

13.32

Tube Size (in.)

3/8

3/8

3/8

INDOOR COIL — TYPE

PLATE FIN

PLATE FIN

PLATE FIN

Rows/F.P.I.

3 / 15

4 / 15

3 / 15

Face Area (.)

3.54

3.54

3.54

Tube Size (in.)

3/8

3/8

3/8

Refrigerant Control

EXPANSION VALVE

EXPANSION VALVE

EXPANSION VALVE

Drain Conn. Size (in.)

3/4 FEMALE NPT

3/4 FEMALE NPT

3/4 FEMALE NPT

OUTDOOR FAN — TYPE

PROPELLER

PROPELLER

PROPELLER

Dia. (in.)

23.4

23.4

23.4

Drive/No. Speeds

DIRECT / 1

DIRECT / 1

DIRECT / 1

*********.w.g.7

2570

3320

3260

Motor — HP/R.P.M.

1/12 / 810

1/5 / 830

1/6 / 830

Volts/Ph/Hz

208-230/1/60

208-230/1/60

208-230/1/60

F.L. Amps/L.R. Amps

0.54 / 0.95

1.1 / 1.9

1.0 / 1.7

INDOOR FAN — TYPE

CENTRIFUGAL

CENTRIFUGAL

CENTRIFUGAL

Dia x Width (in.)

10 X 10

10 X 10

10 X 10

Drive/No. Speeds

DIRECT / VARIABLE

DIRECT / VARIABLE

DIRECT / VARIABLE

*********.w.g.

SEE FAN PERFORMANCE TABLE

SEE FAN PERFORMANCE TABLE

SEE FAN PERFORMANCE TABLE

Motor — HP/R.P.M.

1/2 / VARIABLE

1/2 / VARIABLE

1/2 / VARIABLE

Volts/Ph/Hz

200-230/1/60

200-230/1/60

208-230/1/60

F.L. Amps/L.R. Amps

4.3 / 4.3

4.3 / 4.3

4.3 / 4.3

COMBUSTION FAN — TYPE

CENTRIFUGAL

CENTRIFUGAL

CENTRIFUGAL

Drive/No. Speeds

DIRECT / 2

DIRECT / 2

DIRECT / 2

Motor — HP/R.P.M.

1/20 / 3350/2600

1/20 / 3350/2600

1/20 / 3350/2600

Volts/Ph/Hz

208-230/1/60

208-230/1/60

208-230/1/60

FLA

0.34

0.34

0.34

FILTER / FURNISHED

NO

NO

NO

Type Recommended

THROWAWAY

THROWAWAY

THROWAWAY

Recmd. Face Area (sq. ft.)

4

4

4

REFRIGERANT

R410A

R410A

R410A

Charge (lbs.)

6.0

7.9

6.30

GAS PIPE SIZE (in.)

1/2

1/2

1/2

DIMENSIONS

H X W X L

H X W X L

H X W X L

Crated (in.)

45.86 / 44.5 / 52.03

47.86 / 44.5 / 52.03

45.86 / 44.5 / 52.03

WEIGHT

Shipping (lbs.) / Net (lbs.)

481 / 385

488 / 392

481 / 385

4YCY4036C1090A

208-230/1/60

38000

1210

3.166

12.0 / 14.2

69

72000

90000

81

40 / 70

3 / #37

208-230/1/60

24.6

40

40

SCROLL

208-230/1/60

15.4 / 83

SPINE-FIN

2 / 24

15.49

3/8

PLATE FIN

4 / 15

3.54

3/8

EXPANSION VALVE

3/4 FEMALE NPT

PROPELLER

23.4

DIRECT / 1

3320

1/5 / 830

208-230/1/60

1.1 / 1.9

CENTRIFUGAL

10 X 10

DIRECT / VARIABLE

SEE FAN PERFORMANCE TABLE

1/2 / VARIABLE

200-230/1/60

4.3 / 4.3

CENTRIFUGAL

DIRECT / 2

1/20 / 3350/2600

208-230/1/60

0.34

NO

THROWAWAY

4

R410A

7.9

1/2

H X W X L

47.86 / 44.5 / 52.03

493 / 397

1 Certified in accordance with the Unitary Air-Conditioner Equipment certification program, which is based on AHRI Standard 210/240. Sound

Power values are not adjusted for AHRI 270-95 tonal corrections.

2 All models are certified to UL 1995. Ratings shown are for elevations up to 2000 ft. For higher elevations reduce ratings at a rate of 4% per

1000 ft. elevation.

3 Convertible to LPG.

4 This value is approximate. For more precise value, see Unit Nameplate.

5 Based on U.S. Government Standard Tests.

6 Filters must be installed in return air stream. Square footages listed are based on 300 face velocity. If permanent filters are used size

per manufacturer's recommendation with a clean resistance of 0.05" W.C.

7 Standard Air - Dry Coil - Outdoor.

5

General Data

MODEL

4YCY4036B3075A

RATED Volts/PH/Hz

208-230/3/60

Performance Cooling BTUH

36000

Indoor Airflow (CFM)

1210

Power Input (KW)

3.284

EER/SEER(BTU/Watt-Hr.)

11.6 / 14.2

Sound Power Rating [dB(A)]

69

Performance Heating

Input BTUH - 1st Stage (Natural Gas)

56250

Input BTUH - 2nd Stage (Natural Gas)

75000

AFUE

80

Temp. Rise — Min/Max (°F)

30 / 60

Orifice Qty / Drill Size (Natural Gas)

2 / #33

POWER CONN.—V/PH/HZ

208-230/3/60

Min. Brch. Cir. Ampacity

19.8

Fuse Size — Max. (amps)

30

Fuse Size — Recmd. (amps)

30

COMPRESSOR

SCROLL

Volts/Ph/Hz

208-230/3/60

R.L. Amps — L.R. Amps

11.5 / 77

OUTDOOR COIL — TYPE

SPINE-FIN

Rows/F.P.I.

2 / 24

Face Area (.)

15.49

Tube Size (in.)

3/8

INDOOR COIL — TYPE

PLATE FIN

Rows/F.P.I.

4 / 15

Face Area (.)

3.54

Tube Size (in.)

3/8

Refrigerant Control

EXPANSION VALVE

Drain Conn. Size (in.)

3/4 FEMALE NPT

OUTDOOR FAN — TYPE

PROPELLER

Dia. (in.)

23.4

Drive/No. Speeds

DIRECT / 1

*********.w.g.7

3280

Motor — HP/R.P.M.

1/5 / 830

Volts/Ph/Hz

208-230/1/60

F.L. Amps/L.R. Amps

1.1 / 1.9

INDOOR FAN — TYPE

CENTRIFUGAL

Dia x Width (in.)

10 X 10

Drive/No. Speeds

DIRECT / VARIABLE

*********.w.g.

SEE FAN PERFORMANCE TABLE

Motor — HP/R.P.M.

1/2 / VARIABLE

Volts/Ph/Hz

200-230/1/60

F.L. Amps/L.R. Amps

4.3 / 4.3

COMBUSTION FAN — TYPE

CENTRIFUGAL

Drive/No. Speeds

DIRECT / 2

Motor — HP/R.P.M.

1/45 / 2800/1500

Volts/Ph/Hz

208-230/1/60

FLA

0.34

FILTER / FURNISHED

NO

Type Recommended

THROWAWAY

Recmd. Face Area (sq. ft.)

4

REFRIGERANT

R410A

Charge (lbs.)

6.75

GAS PIPE SIZE (in.)

1/2

DIMENSIONS

H X W X L

Crated (in.)

47.86 / 44.5 / 52.03

WEIGHT

Shipping (lbs.) / Net (lbs.)

488 / 392

4YCY4036A3096A

208-230/3/60

36000

1210

3.284

11.6 / 14.2

69

72000

96000

80

40 / 70

3 / #37

208-230/3/60

19.8

30

30

SCROLL

208-230/3/60

11.5 / 77

SPINE-FIN

2 / 24

15.49

3/8

PLATE FIN

4 / 15

3.54

3/8

EXPANSION VALVE

3/4 FEMALE NPT

PROPELLER

23.4

DIRECT / 1

3280

1/5 / 830

208-230/1/60

1.1 / 1.9

CENTRIFUGAL

10 X 10

DIRECT / VARIABLE

SEE FAN PERFORMANCE TABLE

1/2 / VARIABLE

200-230/1/60

4.3 / 4.3

CENTRIFUGAL

DIRECT / 2

1/45 / 2800/1500

208-230/1/60

0.34

NO

THROWAWAY

4

R410A

6.75

1/2

H X W X L

47.86 / 44.5 / 52.03

493 / 397

4YCY4042C1090A

208-230/1/60

42000

1370

3.5

12.0 / 14.25

74

72000

90000

81

30 / 60

3 / #37

208-230/1/60

31.5

50

50

SCROLL

208-230/1/60

18.6 / 105

SPINE-FIN

2 / 24

18.01

3/8

PLATE FIN

3 / 15

5

3/8

EXPANSION VALVE

3/4 FEMALE NPT

PROPELLER

28.2

DIRECT / 1

4480

1/4 / 825

208-230/1/60

1.5 / 3.4

CENTRIFUGAL

11 X 10

DIRECT / VARIABLE

SEE FAN PERFORMANCE TABLE

3/4 / VARIABLE

208-230/1/60

6.8 / 6.8

CENTRIFUGAL

DIRECT / 2

1/20 / 3350/2600

208-230/1/60

0.34

NO

THROWAWAY

5.3

R410A

6.8125

1/2

H X W X L

47.86 / 47.4 / 61.75

653 / 525

1 Certified in accordance with the Unitary Air-Conditioner Equipment certification program, which is based on AHRI Standard 210/240. Sound

Power values are not adjusted for AHRI 270-95 tonal corrections.

2 All models are certified to UL 1995. Ratings shown are for elevations up to 2000 ft. For higher elevations reduce ratings at a rate of 4% per

1000 ft. elevation.

3 Convertible to LPG.

4 This value is approximate. For more precise value, see Unit Nameplate.

5 Based on U.S. Government Standard Tests.

6 Filters must be installed in return air stream. Square footages listed are based on 300 face velocity. If permanent filters are used size

per manufacturer's recommendation with a clean resistance of 0.05" W.C.

7 Standard Air - Dry Coil - Outdoor.

6

General Data

MODEL

RATED Volts/PH/Hz

Performance Cooling BTUH

Indoor Airflow (CFM)

Power Input (KW)

EER/SEER(BTU/Watt-Hr.)

Sound Power Rating [dB(A)]

Performance Heating

Input BTUH - 1st Stage (Natural Gas)

Input BTUH - 2nd Stage (Natural Gas)

AFUE

Temp. Rise — Min/Max (°F)

Orifice Qty / Drill Size (Natural Gas)

POWER CONN.—V/PH/HZ

Min. Brch. Cir. Ampacity

Fuse Size — Max. (amps)

Fuse Size — Recmd. (amps)

COMPRESSOR

Volts/Ph/Hz

R.L. Amps — L.R. Amps

OUTDOOR COIL — TYPE

Rows/F.P.I.

Face Area (.)

Tube Size (in.)

INDOOR COIL — TYPE

Rows/F.P.I.

Face Area (.)

Tube Size (in.)

Refrigerant Control

Drain Conn. Size (in.)

OUTDOOR FAN — TYPE

Dia. (in.)

Drive/No. Speeds

*********.w.g.7

Motor — HP/R.P.M.

Volts/Ph/Hz

F.L. Amps/L.R. Amps

INDOOR FAN — TYPE

Dia x Width (in.)

Drive/No. Speeds

*********.w.g.

Motor — HP/R.P.M.

Volts/Ph/Hz

F.L. Amps/L.R. Amps

COMBUSTION FAN — TYPE

Drive/No. Speeds

Motor — HP/R.P.M.

Volts/Ph/Hz

FLA

FILTER / FURNISHED

Type Recommended

Recmd. Face Area (sq. ft.)

REFRIGERANT

Charge (lbs.)

GAS PIPE SIZE (in.)

DIMENSIONS

Crated (in.)

WEIGHT

Shipping (lbs.) / Net (lbs.)

4YCY4048C1090A

208-230/1/60

48500

1605

4.041

12 / 14.2

73

72000

90000

81

30 / 60

3 / #37

208-230/1/60

35.4

50

50

SCROLL

208-230/1/60

21.8 / 117

SPINE-FIN

2 / 24

18.01

3/8

PLATE FIN

3 / 15

5.0

3/8

EXPANSION VALVE

3/4 FEMALE NPT

PROPELLER

28.2

DIRECT / 1

4470

1/4 / 825

208-230/1/60

1.4 / 3.5

CENTRIFUGAL

11 X 10

DIRECT / VARIABLE

SEE FAN PERFORMANCE TABLE

3/4 / VARIABLE

200-230/1/60

6.8 / 6.8

CENTRIFUGAL

DIRECT / 2

1/20 / 3350/2600

208-230/1/60

0.34

NO

THROWAWAY

5.3

R410A

8.0

1/2

H X W X L

47.86 / 47.4 / 61.75

669 / 541

4YCY4048C1115A

208-230/1/60

48500

1605

4.041

12 / 14.2

73

90000

115000

81

40 / 70

3 / #32

208-230/1/60

35.4

50

50

SCROLL

208-230/1/60

21.8 / 117

SPINE-FIN

2 / 24

18.01

3/8

PLATE FIN

3 / 15

5.0

3/8

EXPANSION VALVE

3/4 FEMALE NPT

PROPELLER

28.2

DIRECT / 1

4470

1/4 / 825

208-230/1/60

1.4 / 3.37

CENTRIFUGAL

11 X 10

DIRECT / VARIABLE

SEE FAN PERFORMANCE TABLE

3/4 / VARIABLE

200-230/1/60

6.8 / 6.8

CENTRIFUGAL

DIRECT / 2

1/20 / 3350/2600

208-230/1/60

0.34

NO

THROWAWAY

5.3

R410A

8.0

1/2

H X W X L

47.86 / 47.4 / 61.75

675 / 547

4YCY4048B3096A

208-230/3/60

48000

1605

4.034

11.9 / 14.2

73

72000

96000

80

30 / 60

3 / #37

208-230/3/60

26.4

40

40

SCROLL

208-230/3/60

14.6 / 91

SPINE-FIN

2 / 24

18.01

3/8

PLATE FIN

3 / 15

5.0

3/8

EXPANSION VALVE

3/4 FEMALE NPT

PROPELLER

28.2

DIRECT / 1

4470

1/4 / 825

208-230/1/60

1.4 / 3.5

CENTRIFUGAL

11 X 10

DIRECT / VARIABLE

SEE FAN PERFORMANCE TABLE

3/4 / VARIABLE

200-230/1/60

6.8 / 6.8

CENTRIFUGAL

DIRECT / 2

1/45 / 2800/1500

208-230/1/60

0.34

NO

THROWAWAY

5.3

R410A

8.2

1/2

H X W X L

47.86 / 47.4 / 61.75

653 / 525

1 Certified in accordance with the Unitary Air-Conditioner Equipment certification program, which is based on AHRI Standard 210/240. Sound

Power values are not adjusted for AHRI 270-95 tonal corrections.

2 All models are certified to UL 1995. Ratings shown are for elevations up to 2000 ft. For higher elevations reduce ratings at a rate of 4% per

1000 ft. elevation.

3 Convertible to LPG.

4 This value is approximate. For more precise value, see Unit Nameplate.

5 Based on U.S. Government Standard Tests.

6 Filters must be installed in return air stream. Square footages listed are based on 300 face velocity. If permanent filters are used size

per manufacturer's recommendation with a clean resistance of 0.05" W.C.

7 Standard Air - Dry Coil - Outdoor.

7

General Data

MODEL

RATED Volts/PH/Hz

Performance Cooling BTUH

Indoor Airflow (CFM)

Power Input (KW)

EER/SEER(BTU/Watt-Hr.)

Sound Power Rating [dB(A)]

Performance Heating

Input BTUH - 1st Stage (Natural Gas)

Input BTUH - 2nd Stage (Natural Gas)

AFUE

Temp. Rise — Min/Max (°F)

Orifice Qty / Drill Size (Natural Gas)

POWER CONN.—V/PH/HZ

Min. Brch. Cir. Ampacity

Fuse Size — Max. (amps)

Fuse Size — Recmd. (amps)

COMPRESSOR

Volts/Ph/Hz

R.L. Amps — L.R. Amps

OUTDOOR COIL — TYPE

Rows/F.P.I.

Face Area (.)

Tube Size (in.)

INDOOR COIL — TYPE

Rows/F.P.I.

Face Area (.)

Tube Size (in.)

Refrigerant Control

Drain Conn. Size (in.)

OUTDOOR FAN — TYPE

Dia. (in.)

Drive/No. Speeds

*********.w.g.7

Motor — HP/R.P.M.

Volts/Ph/Hz

F.L. Amps/L.R. Amps

INDOOR FAN — TYPE

Dia x Width (in.)

Drive/No. Speeds

*********.w.g.

Motor — HP/R.P.M.

Volts/Ph/Hz

F.L. Amps/L.R. Amps

COMBUSTION FAN — TYPE

Drive/No. Speeds

Motor — HP/R.P.M.

Volts/Ph/Hz

FLA

FILTER / FURNISHED

Type Recommended

Recmd. Face Area (sq. ft.)

REFRIGERANT

Charge (lbs.)

GAS PIPE SIZE (in.)

DIMENSIONS

Crated (in.)

WEIGHT

Shipping (lbs.) / Net (lbs.)

4YCY4048B3120A

208-230/3/60

48000

1605

4.034

11.9 / 14.2

73

90000

120000

80

40 / 70

3 / #32

208-230/3/60

26.4

40

40

SCROLL

208-230/3/60

14.6 / 91

SPINE-FIN

2 / 24

18.01

3/8

PLATE FIN

3 / 15

5.0

3/8

EXPANSION VALVE

3/4 FEMALE NPT

PROPELLER

28.2

DIRECT / 1

4470

1/4 / 825

208-230/1/60

1.4 / 3.37

CENTRIFUGAL

11 X 10

DIRECT / VARIABLE

SEE FAN PERFORMANCE TABLE

3/4 / VARIABLE

200-230/1/60

6.8 / 6.8

CENTRIFUGAL

DIRECT / 2

1/45 / 2800/1500

208-230/1/60

0.34

NO

THROWAWAY

5.3

R410A

8.2

1/2

H X W X L

47.86 / 47.4 / 61.75

659 / 531

4YCY4060C1115A

208-230/1/60

58500

1800

5.478

12/14.0

76

90000

115000

81

30 / 60

3 / #32

208-230/1/60

42.3

60

60

SCROLL

208-230/1/60

26.9 / 145

SPINE-FIN

2 / 24

23.57

3/8

PLATE FIN

4 / 15

5.0

3/8

EXPANSION VALVE

3/4 FEMALE NPT

PROPELLER

28.2

DIRECT / 1

5730

1/3 / 830

208-230/1/60

1.7 / 3.5

CENTRIFUGAL

11 X 10

DIRECT / VARIABLE

SEE FAN PERFORMANCE TABLE

1 / VARIABLE

208-230/1/60

6.9 / 6.9

CENTRIFUGAL

DIRECT / 2

1/20 / 3350/2600

208-230/1/60

0.34

NO

THROWAWAY

5.3

R410A

9.75

1/2

H X W X L

51.86 / 47.4 / 61.75

676 / 548

4YCY4060A3120B

208-230/3/60

58500

1800

5.478

12/14.0

76

90000

120000

80

30 / 60

3 / #32

208-230/3/60

30.6

45

45

SCROLL

208-230/3/60

17.6 / 123

SPINE-FIN

2 / 24

23.57

3/8

PLATE FIN

4 / 15

5.0

3/8

EXPANSION VALVE

3/4 FEMALE NPT

PROPELLER

28.2

DIRECT / 1

5730

1/3 / 830

208-230/1/60

1.7 / 3.5

CENTRIFUGAL

11 X 10

DIRECT / VARIABLE

SEE FAN PERFORMANCE TABLE

1 / VARIABLE

208-230/1/60

6.9 / 6.9

CENTRIFUGAL

DIRECT / 2

1/45 / 2800/1500

208-230/1/60

0.34

NO

THROWAWAY

6.7

R410A

9.75

1/2

H X W X L

51.86 / 47.4 / 61.75

676 / 548

1 Certified in accordance with the Unitary Air-Conditioner Equipment certification program, which is based on AHRI Standard 210/240. Sound

Power values are not adjusted for AHRI 270-95 tonal corrections.

2 All models are certified to UL 1995. Ratings shown are for elevations up to 2000 ft. For higher elevations reduce ratings at a rate of 4% per

1000 ft. elevation.

3 Convertible to LPG.

4 This value is approximate. For more precise value, see Unit Nameplate.

5 Based on U.S. Government Standard Tests.

6 Filters must be installed in return air stream. Square footages listed are based on 300 face velocity. If permanent filters are used size

per manufacturer's recommendation with a clean resistance of 0.05" W.C.

7 Standard Air - Dry Coil - Outdoor.

8

Indoor Fan Performance 4YCY4024

Horizontal Airflow

4YCY4024-HOR

Motor Speed

LOW

MED*

HIGH

Indoor Blower Performance

External Static Pressure (in. wg)

00.10.20.30.40.50.60.7

Watts52668911514

CFM731719700679

Watts-94123254

CFM-793893780

Watts--1243284

CFM--8778929

0.8

229

662

267

778

342

869

0.9

259

659

290

799

426

863

1

300

682

320

800

551

877

Down Airflow

4YCY4024-DOWN

Motor Speed

LOW

MED*

HIGH

External Static Pressure (in. wg)

00.10.20.30.40.50.60.7

Watts357188204

CFM695729734728721715705679

Watts7987106232

CFM846813803794

Watts86113242275

CFM884877895886

0.8

240

675

264

800

319

898

0.9

270

680

306

820

345

910

1

320

685

364

810

385

900

Indoor Fan Performance 4YCY4030

Horizontal Airflow

4YCY4030-HOR

Motor Speed

350 CFM

400 CFM*

450 CFM

Watts

CFM

Watts

CFM

Watts

CFM

-

-

-

-

-

-

0

113

880

146

996

195

1122

0.1

148

905

184

1009

233

1132

External Static Pressure (in. wg)

0.20.30.40.50.60.7

176

917

215

1013

267

1134

203

918

243

1012

303

1136

0.80.9

267

979

312

991

-

-

1

-

-

-

-

-

-

233263291309306

9139

2723

197994

34-

71039-

Down Airflow

4YCY4030-DOWN

Motor Speed

Watts

350 CFM

CFM

Watts

400 CFM*

CFM

Watts

450 CFM

CFM

0

-

-

-

-

-

-

112

871

152

990

191

1090

0.1

147

894

185

995

227

1099

External Static Pressure (in. wg)

0.20.30.40.50.60.7

172

898

211

992

258

1095

198

893

238

984

289

1091

227259288303

884874864851

269303333349

974964955946

321355392432

1011

0.8

286

828

334

937

-

-

0.9

217

788

271

925

-

-

1

-

-

-

-

-

-

*Factory Default Setting

9

Indoor Blower Performance

Indoor Fan Performance 4YCY4036

Horizontal Airflow

4YCY4036-HOR

Motor Speed

LOW

MED*

HIGH

External Static Pressure (in. wg)

00.10.20.30.40.50.60.70.80.91

Watts62562853525

CFM10421033

Watts179236455

CFM511691144

Watts3435469502533563--

CFM49--

Down Airflow

4YCY4036-DOWN

Motor Speed

LOW

MED*

HIGH

External Static Pressure (in. wg)

00.10.20.30.40.50.60.70.80.91

Watts

CFM175990

Watts2252532833449484522575

CFM7711651150

Watts339357396571669--

CFM720--

Indoor Fan Performance 4YCY4042

Horizontal Airflow

4YCY4042-HOR

Motor Speed

0

Watts

CFM

Watts

CFM

Watts

CFM

0.1

External Static Pressure (in. wg)

0.20.30.40.50.60.70.80.91

350 CFM

400 CFM*

450 CFM

-

-

-

-

-

-

160

1206

231

1389

326

1582

185

1211

261

1398

362

1592

214

1213

292

1405

393

1593

245

1215

325

1409

421

1587

277

1215

359

1410

450

1577

308

1214

394

1408

482

1566

339

1212

431

1403

517

1557

368

1208

467

1399

556

1553

396

1201

503

1396

597

1556

423

1190

536

1399

-

-

Down Airflow

4YCY4042-DOWN

Motor Speed

0

Watts

CFM

Watts

CFM

Watts

CFM

0.1

External Static Pressure (in. wg)

0.20.30.40.50.60.70.80.91

350 CFM

400 CFM*

450 CFM

-

-

-

-

-

-

176

1207

253

1405

367

1599

203

1214

290

1411

379

1577

232

1217

323

1413

409

1570

262

1216

355

1412

446

1569

294

1213

386

1407

485

1566

325

1208

420

1399

522

1560

357

1201

455

1389

556

1550

388

1193

491

1377

591

1537

417

1185

526

1366

633

1528

443

1177

558

1357

-

-

*Factory Default Setting

10

Indoor Blower Performance

Indoor Fan Performance 4YCY4048

Horizontal Airflow

4YCY4048-HOR

Motor Speed

LOW

MED*

HIGH

External Static Pressure (in. wg)

00.10.20.30.40.50.60.70.80.91

Watts229487538

CFM14771392

Watts268344848352

CFM915681550

Watts37843264-

CFM871807-

Down Airflow

4YCY4048-DOWN

Motor Speed

LOW

MED*

HIGH

External Static Pressure (in. wg)

00.10.20.30.40.50.60.70.80.91

Watts6478505545

CFM3014101400

Watts2533323794

CFM4816181624

Watts3644643693739764785-

CFM601825-

Indoor Fan Performance 4YCY4060

Horizontal Airflow

4YCY4060-HOR

Motor Speed

LOW

MED*

External Static Pressure (in. wg)

00.10.20.30.40.50.60.70.80.9

Watts394427464568--

CFM9117671756--

Watts6956426698939661108

CFM2000

1

-

-

-

-

Down Airflow

4YCY4060-DOWN

Motor Speed

LOW

MED*

External Static Pressure (in. wg)

00.10.20.30.40.50.60.70.80.9

Watts4434607642680--

CFM6216981692--

Watts749866892894872835

CFM29779

1

-

-

-

-

*Factory Default Setting

11

Indoor Blower Performance

Heating Airflow, horizontal or downflow from .2 to .6” wg.

4YCY4024C1060

Switch SettingsSelectionNominal Airflow

Low StageHigh Stage

7-OFF8-OFFA600850

7-ON8-OFFB625900

7-OFF8-ONC650925

7-ON8-OND700975

4YCY4030

Switch SettingsSelectionNominal Airflow

Low StageHigh Stage

7-OFF8-OFFA7251000

7-ON8-OFFB7751075

7-OFF8-ONC8501150

7-ON8-OND9251250

4YCY4036C *070

Switch SettingsSelectionNominal Airflow

Low StageHigh Stage

7-OFF8-OFFA7251000

7-ON8-OFFB7751075

7-OFF8-ONC8501150

7-ON8-OND9251250

* can be 1 or 3

4YCY4036C *090

Switch SettingsSelectionNominal Airflow

Low StageHigh Stage

7-OFF8-OFFA8251100

7-ON8-OFFB8751175

7-OFF8-ONC9501275

7-ON8-OND10251375

* can be 1 or 3

12

4YCY4042

Switch SettingsSelectionNominal Airflow

Low StageHigh Stage

7-OFF8-OFFA10751375

7-ON8-OFFB11001450

7-OFF8-ONC11501500

7-ON8-OND12001575

4YCY4048C*090

Switch Settings

Selection

Nominal Airflow

Low StageHigh Stage

7-OFF8-OFFA10751375

7-ON8-OFFB11001450

7-OFF8-ONC11501500

7-ON8-OND12001575

* can be 1 or 3

4YCY4048C*115

Switch Settings

Selection

Nominal Airflow

Low StageHigh Stage

7-OFF8-OFFA10501500

7-ON8-OFFB11001575

7-OFF8-ONC11501625

7-ON8-OND12001700

* can be 1 or 3

4YCY4060

Switch SettingsSelection

Nominal Airflow

Low StageHigh Stage

7-OFF8-OFFA13751800

7-ON8-OFFB14501900

7-OFF8-ONC15251975

7-ON8-OND15752075

Typical Field Wiring

UNIT CONTROL BOX

B

G

Y

W1

W2

R

COMMON

FAN

(GR)

COMPRESSOR

HEAT FIRST STAGE

(WH)

HEAT SECOND STAGE

(WH)

24V

GROUND

WIRE

1 PH

POWER

3 PH

POWER

UNIT

NOTE 1

B

G

Y

W1

W2

R

COMMON

FAN

(GR)

COMPRESSOR

HEAT FIRST STAGE

(WH)

HEAT SECOND STAGE

(WH)

24V

B

G

(GR)

Y

W1

(WH)

W2

(WH)

R

C 757192i2

13

Typical Wiring

14

Typical Wiring

15

Optional Equipment

BAYCURB050A Full Perimeter Roof Mounting Curb for *****018-036

17 7/8

46 3/8

3

3 5/8

19 1/2

2 3/16

15

38 7/8

14

1 1/2

19 1/2

The drawings on this page are prepared by the manu-

facturer in order to provide detail regarding job layout

only. These drawings are not intended to be used as a

basis to construct, build or modify the items depicted

in the drawings. The manufacturer is not responsible for

the unauthorized use of these drawings and expressly

disclaims any liability for damages resulting from such

unauthorized use.

43 3/8

35 7/8

16

Optional Equipment

BAYCURB051A Full Perimeter Roof Mounting Curb for *****042-060

15 7/8

56 1/8

3

1 1/2

19 1/2

20

41 7/8

14

The drawings on this page are prepared by the manu-

facturer in order to provide detail regarding job layout

only. These drawings are not intended to be used as a

basis to construct, build or modify the items depicted

in the drawings. The manufacturer is not responsible for

the unauthorized use of these drawings and expressly

disclaims any liability for damages resulting from such

unauthorized use.

10 7/8

4 3/4

19 1/2

38 7/8

53 1/8

17

Optional Equipment

BAYFLTR101, 201B, 1" - 2" Filter Rack

(Mounts in Filter/Coil Section)

Filter

BAYACCDOR1A & BAYACCDOR2A Hinged Filter Access Door

Replaces Filter/Coil Access Panel

The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not

intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer is not responsible for the

unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use.

18

Optional Equipment

BAYECON101,102A Down Discharge Economizer and Rain Hood

(Mounts Over Horizontal Return Air Opening)

HVAC Unit

A

Economizer

rain hood

Outside air

dampers

Return air

dampers

Mist elimi-

nator

Relief

damper

Roofcurb

Required

filter kit, order

separately

Economizer

BAYECON101A

BAYECON102A

Unit Application Models

4TC*,WC*,YC*,DC*

*018-036

4TC*,WC*,YC*, DC*

*042-060

A

20.125"

24.375"

Return

Duct

BAYECON200,201A Horizontal Economizer and Rain Hood

The drawings on this page are

prepared by the manufacturer in

order to provide detail regarding

job layout only. These drawings

are not intended to be used as a

basis to construct, build or modify

the items depicted in the draw-

ings. The manufacturer is not re-

sponsible for the unauthorized use

of these drawings and expressly

disclaims any liability for damages

resulting from such unauthorized

use.

Economizer

A

C

B

D

Gaskets (2)

Duct

E

Rain Hood

Mixed Air Sensor

Economizer

BAYECON200AA

BAYECON201AA

A

22"

26"

B

20"

22-21/32"

C

16-7/8"

19"

D

15-11/16"

17-11/16"

E

11-11/16"

14-11/16"

F

15"

21-3/8"

19

Optional Equipment

BAYOSAH001,002A, 25% Outside Air Damper

(Replaces Filter/Coil Access Panel)

The drawings on this page are prepared by

the manufacturer in order to provide detail

regarding job layout only. These drawings

are not intended to be used as a basis to

construct, build or modify the items de-

picted in the drawings. The manufacturer is

not responsible for the unauthorized use of

these drawings and expressly disclaims any

liability for damages resulting from such

unauthorized use.

A

FULLY

OPEN

D

C

2/3

1/3

B

FULLY

CLOSED

Manual Fresh Air

Model

Unit Application

Models

4YC,WC3018-036

4TC*3018-036,

4W/T/Y/DCY4024-036,

4W/Y/DCZ6036

4YC,WC3042-060,

4TC*3042-060,

4W/T/Y/DCY4042-060,

4W/Y/DCZ6048-060

ABCD

BAYOSAH00122 7/16""20 11/16""12 3/8""9 3/16""

BAYOSAH00225 3/16""20 11/16""12 3/8""9 3/16""

BAYDMPR101,102A, 25% Motorized Outside Air Damper

(Mounts Over Horizontal Return AIr Opening)

A

C

B

E

D

Unit Application Models

4YC,WC3018-036

4TC*3018-036,

4W/T/Y/DCY4024-036,

4W/Y/DCZ6036

4YC,WC3042-060,

4TC*3042-060,

4W/T/Y/DCY4042-060,

4W/Y/DCZ6048-060

ABCDE

BAYDMPR101A

15 13/16""11 13/16""10 1/4""11 1/2""12 1/4""

BAYDMPR102A

18 3/16""15 1/8""10 1/4""11 1/2""12 1/4""

20