最新消息: USBMI致力于为网友们分享Windows、安卓、IOS等主流手机系统相关的资讯以及评测、同时提供相关教程、应用、软件下载等服务。

MultiPlus-II 2x120V 转换器 充电器用户指南说明书

IT圈 admin 57浏览 0评论

2024年10月30日发(作者:冯驰雪)

MultiPlus-II 2x120V Inverter/Charger

120/240V input and output, or 120V input and output (always 120V output when in inverter mode)

The AC input can be supplied from a split phase 120/240V source, or single phase 120V source.

When an AC source is available, the MultiPlus will feed through the AC to its output. The output will therefore mirror the

AC input.

The inverter/charger connects to the neutral and the preferred input line (L1). Power needed to charge the batteries will

therefore be drawn from L1.

The MultiPlus switches to inverter operation when no AC source is available. The inverter output is 120V single phase. In

invert mode, the MultiPlus connects both output lines (L1 and L2) together to provide 120VAC to loads on either line.

Any 240V loads will therefore be supplied only when the MultiPlus is supplied by a split phase AC source. This prevents

heavy loads such as water heaters or 240V air conditioners from discharging the battery.

PowerControl and PowerAssist - Boosting the capacity of the grid or a generator

A maximum grid or generator current can be set. The MultiPlus will then take account of other AC loads and use

whatever is extra for battery charging, thus preventing the generator or grid from being overloaded (PowerControl

function).

PowerAssist takes the principle of PowerControl to a further dimension. Where peak power is so often required only for a

limited period, the MultiPlus-II will compensate insufficient generator, shore or grid power with power from the battery.

When the load reduces, the spare power is used to recharge the battery (available on L1 input only).

Two AC Outputs

The main output has no break functionality. The MultiPlus takes over the supply to the connected 120V loads in the

event of a grid failure or when shore/generator power is disconnected. The transfer time of the L1 output is less than

18 milliseconds so that computers and other electronic equipment will continue to operate without disruption.

The transfer time of the L2 output is longer: approximately 40 milliseconds.

The second (auxiliary) output is live only when AC is available on the input of the MultiPlus. Loads that should not

discharge the battery can be connected to this output.

Virtually unlimited power thanks to parallel and three phase operation

Up to 6 Multis can operate in parallel to achieve higher power output.

In addition to parallel connection, three units of the same model can be configured for three phase output.

In multi-phase setups, L2 is disabled on all units.

On-site system configuring, monitoring and control

Settings can be changed in a matter of minutes with VEConfigure software (computer or laptop and MK3-USB interface

needed).

Several monitoring and control options are available: Cerbo GX, Color Control GX, Venus GX, , CANvu GX, laptop,

computer, Bluetooth (with the optional Smart dongle), Battery Monitor, Digital Multi Control Panel.

Remote configuring and monitoring

Install a Cerbo GX or other GX product to connect to the internet.

Operational data can be stored and displayed on our VRM (Victron Remote Management) website, free of charge.

When connected to the internet, systems can be accessed remotely, and settings can be changed.

Power flow: inverter mode

Power flow, 120VAC-input

Power flow, split phase input

PowerControl & PowerAssist

Transfer switch

Maximum AC input current

DC Input voltage range

Output when in inverter mode

Cont. output power at 25°C (3)

Cont. output power at 25°C

Cont. output power at 40°C

Cont. output power at 65°C

Maximum apparent feed-in power

Peak power

Maximum efficiency

Zero load power

Zero load power in AES mode

Zero load power in Search mode

AC Input

Charge voltage 'absorption'

Charge voltage 'float'

Storage mode

Maximum battery charge current (4)

Battery temperature sensor

Auxiliary output (5)

External AC current sensor (optional)

Programmable relay (6)

Protection (2)

VRM Portal

Our free remote monitoring website (VRM) will display all

system data in a comprehensive graphical format. System

settings can be changed remotely via the portal. Alarms can be

received by e-mail.

communication port

General purpose com. Port (7)

Remote on-off

Operating temperature range

Humidity (non-condensing)

Material & Colour

Protection category

Battery-connection

120/240 V AC-connection

Weight

Dimensions (hxwxd)

Safety

Emission, Immunity

1) Can be adjusted to 50 Hz

2) Protection key:

a) output short circuit

b) overload

c) battery voltage too high

d) battery voltage too low

e) temperature too high

f) 120 VAC on inverter output

g) input voltage ripple too high

Yes (on L1 input)

50 A

50A (each leg)

INVERTER

9,5 – 17 V 19-33V

Output voltage: 120 VAC ± 2%

Frequency

:

60 Hz ± 0,1% (1)

3000 VA

2400 W

2200 W

1700 W

2500 VA

5500 W

93% 94%

15W 11W

10W 8W

4W 4W

CHARGER

Split phase: 180-280 VAC 45 – 65 Hz

Single phase: 90-140 VAC 45 – 65 Hz

14,4 V 28,8 V

13,8 V 27,6 V

13,2 V 26,4 V

120 A 70 A

Yes

GENERAL

50 A (each leg) See note 8

100 A

Yes

a – g

For parallel and three phase operation,

remote monitoring and system integration

Cerbo GX with GX Touch 50

Provides intuitive system control and monitoring

Besides system monitoring and control the Cerbo enables access to

our free remote monitoring website: the VRM Online Portal

Yes, 2x

Yes

-40 to +65°C (-40 -150°F) Fan assisted cooling

max 95%

ENCLOSURE

Steel, blue RAL 5012

IP22

2x2 M8 bolts 2 M8 bolts

Screw terminals 21 mm² (4 AWG)

22 kg (48 lb)

578 x 275 x 148 mm 578 x 275 x 148 mm

(23 x 11 x 6 inch) (23 x 11 x 6 inch)

STANDARDS

EN-IEC 60335-1, EN-IEC 60335-2-29, UL 458

EN 55014-1, EN 55014-2

EN-IEC 61000-3-2, EN-IEC 61000-3-3

IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3

3) Non-linear load, crest factor 3:1

4) Up to 75 ˚ F / 25 ˚ C ambient

5) Switches off when no external AC source available

6) Programmable relay that be set for general alarm,

DC under voltage or genset start/stop function

AC rating: 120 V/4 A

DC rating: 4 A up to 35 VDC, 1 A up to 60 VDC

7) A. o. to communicate with a Lithium-Ion battery BMS

8) The auxiliary output of an early production batch of this

product was rated at 35A instead of 50A. This batch has serial

numbers starting with HQ2107. Later batches, with 50A aux.

output have serial numbers starting with HQ2114 or higher.

VRM app

Monitor and manage your

Victron Energy system from

your smart phone and

tablet. Available for both

iOS and Android.

Smart Dongle

Measures battery voltage and

temperature and allows

monitoring and control with a

smart phone or other

Bluetooth enabled device.

Connection Area

Current sensor 100A:50mA

To implement PowerControl and

PowerAssist and to optimize self-

consumption with external current

sensing.

Maximum current: 50A resp. 100A.

Digital Multi Control Panel

A convenient and low-cost solution for remote

monitoring, with a rotary knob to set

PowerControl and PowerAssist levels.

Victron Energy B.V. | De Paal 35 | 1351 JG Almere | The Netherlands

E-mail:***********************|

2024年10月30日发(作者:冯驰雪)

MultiPlus-II 2x120V Inverter/Charger

120/240V input and output, or 120V input and output (always 120V output when in inverter mode)

The AC input can be supplied from a split phase 120/240V source, or single phase 120V source.

When an AC source is available, the MultiPlus will feed through the AC to its output. The output will therefore mirror the

AC input.

The inverter/charger connects to the neutral and the preferred input line (L1). Power needed to charge the batteries will

therefore be drawn from L1.

The MultiPlus switches to inverter operation when no AC source is available. The inverter output is 120V single phase. In

invert mode, the MultiPlus connects both output lines (L1 and L2) together to provide 120VAC to loads on either line.

Any 240V loads will therefore be supplied only when the MultiPlus is supplied by a split phase AC source. This prevents

heavy loads such as water heaters or 240V air conditioners from discharging the battery.

PowerControl and PowerAssist - Boosting the capacity of the grid or a generator

A maximum grid or generator current can be set. The MultiPlus will then take account of other AC loads and use

whatever is extra for battery charging, thus preventing the generator or grid from being overloaded (PowerControl

function).

PowerAssist takes the principle of PowerControl to a further dimension. Where peak power is so often required only for a

limited period, the MultiPlus-II will compensate insufficient generator, shore or grid power with power from the battery.

When the load reduces, the spare power is used to recharge the battery (available on L1 input only).

Two AC Outputs

The main output has no break functionality. The MultiPlus takes over the supply to the connected 120V loads in the

event of a grid failure or when shore/generator power is disconnected. The transfer time of the L1 output is less than

18 milliseconds so that computers and other electronic equipment will continue to operate without disruption.

The transfer time of the L2 output is longer: approximately 40 milliseconds.

The second (auxiliary) output is live only when AC is available on the input of the MultiPlus. Loads that should not

discharge the battery can be connected to this output.

Virtually unlimited power thanks to parallel and three phase operation

Up to 6 Multis can operate in parallel to achieve higher power output.

In addition to parallel connection, three units of the same model can be configured for three phase output.

In multi-phase setups, L2 is disabled on all units.

On-site system configuring, monitoring and control

Settings can be changed in a matter of minutes with VEConfigure software (computer or laptop and MK3-USB interface

needed).

Several monitoring and control options are available: Cerbo GX, Color Control GX, Venus GX, , CANvu GX, laptop,

computer, Bluetooth (with the optional Smart dongle), Battery Monitor, Digital Multi Control Panel.

Remote configuring and monitoring

Install a Cerbo GX or other GX product to connect to the internet.

Operational data can be stored and displayed on our VRM (Victron Remote Management) website, free of charge.

When connected to the internet, systems can be accessed remotely, and settings can be changed.

Power flow: inverter mode

Power flow, 120VAC-input

Power flow, split phase input

PowerControl & PowerAssist

Transfer switch

Maximum AC input current

DC Input voltage range

Output when in inverter mode

Cont. output power at 25°C (3)

Cont. output power at 25°C

Cont. output power at 40°C

Cont. output power at 65°C

Maximum apparent feed-in power

Peak power

Maximum efficiency

Zero load power

Zero load power in AES mode

Zero load power in Search mode

AC Input

Charge voltage 'absorption'

Charge voltage 'float'

Storage mode

Maximum battery charge current (4)

Battery temperature sensor

Auxiliary output (5)

External AC current sensor (optional)

Programmable relay (6)

Protection (2)

VRM Portal

Our free remote monitoring website (VRM) will display all

system data in a comprehensive graphical format. System

settings can be changed remotely via the portal. Alarms can be

received by e-mail.

communication port

General purpose com. Port (7)

Remote on-off

Operating temperature range

Humidity (non-condensing)

Material & Colour

Protection category

Battery-connection

120/240 V AC-connection

Weight

Dimensions (hxwxd)

Safety

Emission, Immunity

1) Can be adjusted to 50 Hz

2) Protection key:

a) output short circuit

b) overload

c) battery voltage too high

d) battery voltage too low

e) temperature too high

f) 120 VAC on inverter output

g) input voltage ripple too high

Yes (on L1 input)

50 A

50A (each leg)

INVERTER

9,5 – 17 V 19-33V

Output voltage: 120 VAC ± 2%

Frequency

:

60 Hz ± 0,1% (1)

3000 VA

2400 W

2200 W

1700 W

2500 VA

5500 W

93% 94%

15W 11W

10W 8W

4W 4W

CHARGER

Split phase: 180-280 VAC 45 – 65 Hz

Single phase: 90-140 VAC 45 – 65 Hz

14,4 V 28,8 V

13,8 V 27,6 V

13,2 V 26,4 V

120 A 70 A

Yes

GENERAL

50 A (each leg) See note 8

100 A

Yes

a – g

For parallel and three phase operation,

remote monitoring and system integration

Cerbo GX with GX Touch 50

Provides intuitive system control and monitoring

Besides system monitoring and control the Cerbo enables access to

our free remote monitoring website: the VRM Online Portal

Yes, 2x

Yes

-40 to +65°C (-40 -150°F) Fan assisted cooling

max 95%

ENCLOSURE

Steel, blue RAL 5012

IP22

2x2 M8 bolts 2 M8 bolts

Screw terminals 21 mm² (4 AWG)

22 kg (48 lb)

578 x 275 x 148 mm 578 x 275 x 148 mm

(23 x 11 x 6 inch) (23 x 11 x 6 inch)

STANDARDS

EN-IEC 60335-1, EN-IEC 60335-2-29, UL 458

EN 55014-1, EN 55014-2

EN-IEC 61000-3-2, EN-IEC 61000-3-3

IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3

3) Non-linear load, crest factor 3:1

4) Up to 75 ˚ F / 25 ˚ C ambient

5) Switches off when no external AC source available

6) Programmable relay that be set for general alarm,

DC under voltage or genset start/stop function

AC rating: 120 V/4 A

DC rating: 4 A up to 35 VDC, 1 A up to 60 VDC

7) A. o. to communicate with a Lithium-Ion battery BMS

8) The auxiliary output of an early production batch of this

product was rated at 35A instead of 50A. This batch has serial

numbers starting with HQ2107. Later batches, with 50A aux.

output have serial numbers starting with HQ2114 or higher.

VRM app

Monitor and manage your

Victron Energy system from

your smart phone and

tablet. Available for both

iOS and Android.

Smart Dongle

Measures battery voltage and

temperature and allows

monitoring and control with a

smart phone or other

Bluetooth enabled device.

Connection Area

Current sensor 100A:50mA

To implement PowerControl and

PowerAssist and to optimize self-

consumption with external current

sensing.

Maximum current: 50A resp. 100A.

Digital Multi Control Panel

A convenient and low-cost solution for remote

monitoring, with a rotary knob to set

PowerControl and PowerAssist levels.

Victron Energy B.V. | De Paal 35 | 1351 JG Almere | The Netherlands

E-mail:***********************|

发布评论

评论列表 (0)

  1. 暂无评论