2024年11月1日发(作者:禽沛岚)
Cable and Board Presence -
Message Code:
"x1Axx"
Message
Code
E1A10
E1A11
E1A12
E1A14
E1A15
E1A16
E1A17
E1A18
Message
String
PDBPwrCable
PCIRsrConfig
PCIRsrMissing
SAS Cable A
SAS Cable B
SAS Cable FB
PwrCable FB
PDBCtrl Cable
Message Priority
High
High
High
Low
Low
Low
Low
High
Message Comments
PDB power cable to the planar is missing or bad
and system will not power on.
PCI risers are not configured correctly; some
invalid configurations prevent system power on.
One or all of the PCI risers is missing. This
prevents system power on.
SAS cable A is missing or bad.
SAS cable B is missing or bad.
Flex bay SAS cable is missing or bad.
Flex bay power cable is missing or bad.
PDB control cable to the planar is missing or bad
and system will not power on.
Temperature -
Message Code:
"x11xx"
Message
Code
E1114
Message
String
Temp Ambient
Message Priority
Med
Message Comments
Ambient temperature has a reached a point
outside of the allowed range.
Memory has exceeded allowable temperature
E1116Temp MemoryHighand has been disabled to prevent damage to the
components.
Voltages -
Message Code:
"x12xx"
Message
Code
E1210
Message
String
CMOSBatt
Message Priority
Low
Message Comments
CMOS battery is missing or the voltage is outside
of the allowable range.
PERC5I RAID battery charger has reported to the
Server Management that the battery is either
E1211ROMBBattLowmissing, can't charge the battery (possibly
because of high temperatures), or the battery is
bad.
This is a predictive failure warning message
W1228
ROMBBatt<
24 hr
telling the user that the PERC5I RAID battery has
Lowless then 24 hours of charge left init. We provide
this message as a warning message to the
customer.
E1214
E1215
E1216
E1217
E1218
E1219
E1221
1.5VPwrGd
1.8VPwrGd
3.3VPwrGd
5VPwrGd
PCIRsr5VPwr
Gd
BackplanePwr
Gd
Flex
BayPwrGd
High
High
High
High
High
High
High
1.5 VV voltage regulator has failed.
1.8 VV voltage regulator has failed.
3.3 V voltage regulator has failed.
5 V voltage regulator has failed.
PCI Riser 5 V voltage regulator has failed.
Backplane voltage regulator has failed.
Flex Bay voltage regulator power good has failed.
E1222
E1223
E1225
E1226
VCACHE
#PwrGd
VRM #PwrGd
ESB
1.5VPwrGd
PCIRsr1.5VPw
rGd
LinearPwrGd
0.9VPwrGd
CPU #
VCORE
CPU
VTTPwrGd
0.9 V Over
Voltage
CPU Power
Fault
Message
String
RPM Fan ##
RPM Fan Mod
#A
RPM Fan Mod
#B
RPM Fan Mod
#C
RPM Fan Mod
#D
Fan
Redundancy
High
High
High
High
VCACHE # voltage regulator has failed.
VRM # voltage regulator has failed.
ESB 1.5 VV voltage regulator has failed.
PCI Riser 1.5 VV voltage regulator has failed.
Linear voltage regulator(s) has failed. Represents
E1227
E1228
E1229
E122A
E122B
E122C
High
High
High
High
High
High
status of multiple voltage regulators used in the
video and LOM circuitry.
Memory VTT voltage regulator has failed.
Processor # VCORE voltage regulator has failed.
Processor VTT voltage regulator has failed.
0.9 V regulator voltage has exceeded the
allowable voltage range.
A voltage regulator failure was detected when the
processor regulator(s) was enabled.
Fans -
Message Code:
"x13xx"
Message
Code
E1310
E1311
E1311
E1311
E1311
Message Priority
Low
Low
Low
Low
Low
Message Comments
RPM of fan ## is outside of the intended
operating range.
RPM of fan A in the # module is outside of the
intended operating range.
Same as above except for fan B of module #.
Same as above except for fan C of module #.
Same as above except for fan D of module #.
The system is no longer fan redundant. Another
E1313Lowfan failure would put the system at risk of over-
heating.
Processors -
Message Code:
"x14xx"
Message
Code
Message
String
Message PriorityMessage Comments
Processor # has had an internal error (IERR), but
E1410CPU # IERRHigh
this does not always mean that CPU is the
problem .There are a large variety of issues that
cause an IERR.
Processor # has encountered a Thermtrip(over-
temperature) event.
Processor # is missing/bad and the system is in
an unsupported configuration.
Processors are not compatible as defined by Dell
.System is in an unsupported configuration.
BIOS has reported a processor protocol error.
E1414
E1418
E141C
E141F
CPU
#Thermtrip
CPU #
Presence
CPU Mismatch
CPU Protocol
High
High
High
High
E1420
E1421
E1422
CPU Bus
PERR
CPU Init
CPU
MachineChk
High
High
High
BIOS has reported a processor bus PERR (parity
error).
BIOS has reported a processor initialization error.
BIOS has reported a machine check error.
System Memory -
Message Code:
"x21xx"
Message
Code
Message
String
MBECrdx
DIMM ## & ##
Message PriorityMessage Comments
One of the DIMMs in the set implicated by "## &
E2110High
##" has had a multi-bit error (MBE).If no memory
riser is present the “Crdx” string is left out of the
message.“x” is the memory riser, A-Z.
BIOS has disabled memory single-bit error (SBE)
SBE Log
E2111DisableCrdx
DIMM ##
High
logging and will not log anymore SBEE's until the
system is rebooted.## represents DIMM
implicated by BIOS .If no memory riser is present
the “Crd x” string is left out of the message.“x” is
the memory riser, A-Z.
BIOS has spared the memory because it has
E2112
MemSpareCrd
x DIMM ##
determined the memory had too many errors.##
Highrepresents DIMM implicated by BIOS. If no
memory riser is present the “Crdx” string is left
out of the message.“x” is the memory riser, A-Z.
BIOS has disabled memory mirroring because it
Mem Mirror
E2113Crd x DIMM
## & ##
High
has determined one half of the mirror has had too
many errors. ## & ## represents DIMM pair
implicated by BIOS. If no memory riser is present
the “Crdx” string is left out of the message.“x” is
the memory riser, A-Z.
I2114
I2115
I2116
E2117
MemRaid
MemAdded
Card x
MemRemoved
MemHot Plug
Low
Low
Low
Low
BIOS Memory RAID Bank
Memory has been added while the system is
running.
Memory has been removed while the system is
running.
Memory hot-plug operation has failed.
Northbound FBD CRC error on non-redundant
entry. One of the connections in the FBD link on
E2118
Fatal
NBMemCRC
High
the Northbound (towards the MCH) side is
"broken".This is determined by the MCH when
two CRC errors have been detected twice in a
row.
FBD alert on non-redundant entry. One of the
connections in the FBD link on the Southbound
E2119
Fatal
SBMemCRC
High
(towards the AMB'son the FBDIMM's) side is
"broken".This is determined by the MCH when
two CRC errors have been detected twice in a
row.
DELL服务器LCD信息代码的所
錯誤代碼故障硬件相關說明
E1114
E1116
E1210
E1211
E12nn
E1229
E122B
E122C
E1310
E1410
E1414
E1418
E141C
E141F
E1420
E1421
E1422
E1618
E161C
E1620
E1710
E1711
E1712
E1714
E171F
Temp Ambient
Temp Memory
CMOS Batt
ROMB Batt
XX PwrGd
CPU # VCORE
0.9V Over Voltage
CPU Power Fault
RPM Fan ##
CPU # IERR
CPU # Thermtrip
CPU # Presence
CPU Mismatch
CPU Protocol
CPU Bus PERR
CPU Init
E1422
E1618
PS # Input Lost
PS # Input Range
I/O Channel Chk
PCI PERR B## D## F##
PCI PERR Slot #
PCI SERR B## D## F##
PCI SERR Slot #
Unknown Err
PCIE Fatal Err B## D## F##
PCIE Fatal Err Slot #
E1913
E2010
E2011
E2012
E2013
E2014
E2015
E2016
E2017
E2018
E2019
E201A
E201B
E201C
系统周围环境温度超出允许范围。
内存已超过允许温度,系统已将其禁用以防止损坏组件。
缺少 CMOS 电池,或电压超出允许范围。
RAID 电池丢失、损坏或因温度问题而无法再充电。
指定的稳压器出现故障。
处理器 # VCORE 稳压器出现故障。
0.9 V 稳压器电压已超过电压允许范围
启动处理器稳压器之后,检测到稳压器故障
指定的冷却风扇的 RPM 超出允许的运行范围。
指定的微处理器正在报告系统错误。
指定的微处理器超出了允许的温度范围并已停止运行。
指定的处理器丢失或损坏,系统的配置不受支持。
处理器的配置不受 Dell 支持。
系统 BIOS 已报告处理器协议错误。
系统 BIOS 已报告处理器总线奇偶校验错误。
系统 BIOS 已报告处理器初始化错误。
系统 BIOS 已报告机器检查错误。
电源设备电压超出允许范围;指定的电源设备安装错误或出现故障。
指定的电源设备的电源不可用,或超出了允许范围。
指定的电源设备的电源不可用,或超出了允许范围。
系统 BIOS 已报告 I/O 通道检查错误。
系统 BIOS 已报告组件的 PCI 奇偶校验错误,该组件所在的 PCI 配置空
系统 BIOS 已报告组件的 PCI 奇偶校验错误,该组件位于 PCI 插槽 #。
系统 BIOS 已报告组件的 PCI 系统错误,该组件所在的 PCI 配置空间位
系统 BIOS 已报告组件的 PCI 系统错误,该组件位于插槽 #。
系统 BIOS 已确定系统中存在错误,但无法确定错误来源。
系统 BIOS 已报告组件的 PCIe 致命错误,该组件所在的 PCI 配置空间
系统 BIOS 已报告组件的 PCIe 致命错误,该组件位于插槽 #。
卸下并重置 PCI 扩充卡。如果问题仍然存在,请参阅排除扩充卡故障
CPU & Firmware Mismatch
BMC 固件不支持 CPU。
No Memory
系统中没有安装内存。
Mem Config Err
检测到内存,但是内存不可配置。配置内存期间检测到错误。
Mem Mirror DIMM ## & ##
已配置内存,但内存不可用。内存子系统
Shadow BIOS Fail
系统 BIOS 无法将其快擦写映像复制到内存中。
CMOS Fail
CMOS 出现故障。CMOS RAM 未正常工作。
DMA Controller
DMA 控制器出现故障。
Int Controller
中断控制器出现故障。
Timer Fail
计时器刷新故障。
Prog Timer
可编程间隔计时器错误。
Parity Error
奇偶校验错误。
SIO Err
SIO 出现故障。
Kybd Controller
键盘控制器出现故障。
SMI Init
系统管理中断 (SMI) 初始化失败。
E201D
E201E
E201F
E2020
E2021
E2022
E2110
E2111
E2112
E2113
Shutdown Test
BIOS 关闭系统检测失败。
POST Mem Test
BIOS POST 内存检测失败。
DRAC Config
Dell 远程访问控制器 (DRAC) 配置失败。
CPU Config
CPU 配置失败。
Memory Population
内存配置不正确。内存安装顺序不正确。
POST Fail
视频后出现一般故障。
MBE DIMM ## & ##
“## & ##”指示的 DIMM 组中的一个 DIMM 发生内存多位错误 (MBE)
SBE Log Disable DIMM ##
系统 BIOS 已禁用内存单位错误 (SBE) 记录,在重新引导系统之前,不
Mem Spare DIMM ##
系统 BIOS 确定内存中有太多错误,因此已将内存释放。“## & ##”表
Mem Mirror DIMM ## & ##
系统 BIOS 确定一半镜像中有太多错误,因此已将内存禁用。“## &
E2118
E2119
I1910
I1911
I1912
W1228
Fatal NB Mem CRC
北侧的全缓冲 DIMM (FBD) 内存子系统链接中的一个连接失败。
Fatal SB Mem CRC
南侧的 FBD 内存子系统链接中的一个连接失败。
Intrusion
主机盖被卸下。
>3 ERRs Chk Log
LCD 溢出信息。
LCD 上最多只能按顺序显示三条错误信息。第四条信息显示为标准的
SEL Full
系统事件日志中的事件已满,无法再记录更多事件。
ROMB Batt < 24hr
预先警告 RAID 电池只剩下不足 24 小时的电量。
Message Code:
"x1Axx"
Minimum Action Required to Remove
Message from LCD
Failing device is reseated/replaced/repaired.
Failing device is reseated/replaced/repaired.
Failing device is reseated/replaced/repaired.
Failing device is reseated/replaced/repaired.
Failing device is reseated/replaced/repaired.
Failing device is reseated/replaced/repaired.
Failing device is reseated/replaced/repaired.
Failing device is reseated/replaced/repaired.
Exists in
SEL?
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
System Phase When
Event Can Occur?
Pre-Post
Pre-Post
Pre-Post
Any
Any
Any
Any
Any
Message Code:
"x11xx"
Minimum Action Required to Remove
Message from LCD
Temperature returns to allowable range.
Exists in
SEL?
Yes
System Phase When
Event Can Occur?
Any
AC Cycle or SEL clearYesAny
Message Code:
"x12xx"
Minimum Action Required to Remove
Message from LCD
Failing device is reseated/replaced/repaired.
Exists in
SEL?
Yes
System Phase When
Event Can Occur?
Any
Failing device is reseated/replaced/
Battery charges to > 24 hours of sustained
charge.
YesAny
AC Cycle or SEL clear
AC Cycle or SEL clear
AC Cycle or SEL clear
AC Cycle or SEL clear
AC Cycle or SEL clear
AC Cycle or SEL clear
AC Cycle or SEL clear
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Any
Any
Any
Any
Any
Any
Any
AC Cycle or SEL clear
AC Cycle or SEL clear
AC Cycle or SEL clear
AC Cycle or SEL clear
Yes
Yes
Yes
Yes
Any
Any
Any
Any
AC Cycle or SEL clear
AC Cycle or SEL clear
AC Cycle or SEL clear
AC Cycle or SEL clear
AC Cycle or SEL clear
AC Cycle or SEL clear
Yes
Yes
Yes
Yes
Yes
Yes
Any
Any
Any
Any
Any
Any
ssage Code:
"x13xx"
Minimum Action Required to Remove
Message from LCD
Fan RPM reading returns to a point inside of
the intended operating range.
Fan RPM reading returns to a point inside of
the intended operating range.
Fan RPM reading returns to a point inside of
the intended operating range.
Fan RPM reading returns to a point inside of
the intended operating range.
Fan RPM reading returns to a point inside of
the intended operating range.
Fan redundancy is regained, which requires
all fans to be operating within the intended
operating range.
YesAny
Exists in
SEL?
Yes
Yes
Yes
Yes
Yes
System Phase When
Event Can Occur?
Any
Any
Any
Any
Any
Message Code:
"x14xx"
Minimum Action Required to Remove
Message from LCD
Exists in
SEL?
System Phase When
Event Can Occur?
AC Cycle or SEL clearYesAny
AC Cycle or SEL clear
AC Cycle or SEL clear
AC Cycle or SEL clear
AC Cycle or SEL clear
Yes
Yes
Yes
Yes
Any
Pre-POST
Pre-POST
POST, After POST
AC Cycle or SEL clear
AC Cycle or SEL clear
AC Cycle or SEL clear
Yes
Yes
Yes
POST, After POST
POST, After POST
POST, After POST
Message Code:
"x21xx"
Minimum Action Required to Remove
Message from LCD
Exists in
SEL?
System Phase When
Event Can Occur?
AC Cycle or SEL clearYesPOST, After POST
System resetYesPOST, After POST
System resetYesPOST, After POST
System resetYesPOST, After POST
User action, sensor return to normal
AC Cycle or SEL clear
AC Cycle or SEL clear
AC Cycle or SEL clear
Yes
Yes
Yes
Yes
Any
Any
Any
Any
AC Cycle or SEL clearYesPOST, After POST
AC Cycle or SEL clearYesPOST, After POST
码的所代表的含義
禁用以防止损坏组件。
出允许范围。
度问题而无法再充电。
压器故障
允许的运行范围。
范围并已停止运行。
系统的配置不受支持。
奇偶校验错误。
的电源设备安装错误或出现故障。
用,或超出了允许范围。
用,或超出了允许范围。
奇偶校验错误,该组件所在的 PCI 配置空间位于总线 ##,设备 ##,功能 ##。
奇偶校验错误,该组件位于 PCI 插槽 #。
系统错误,该组件所在的 PCI 配置空间位于总线 ##,设备 ##,功能 ##。
系统错误,该组件位于插槽 #。
错误,但无法确定错误来源。
致命错误,该组件所在的 PCI 配置空间位于总线 ##,设备 ##,功能 ##。
致命错误,该组件位于插槽 #。
果问题仍然存在,请参阅排除扩充卡故障。
配置内存期间检测到错误。
。内存子系统出现故障。
像复制到内存中。
未正常工作。
配置失败。
正确。
的一个 DIMM 发生内存多位错误 (MBE)。
误 (SBE) 记录,在重新引导系统之前,不会再记录更多的 SBE。“##”表示 BIOS 指示的 DIMM。
错误,因此已将内存释放。“## & ##”表示 BIOS 指示的 DIMM 对。
太多错误,因此已将内存禁用。“## & ##”表示 BIOS 指示的 DIMM 对。
存子系统链接中的一个连接失败。
中的一个连接失败。
三条错误信息。第四条信息显示为标准的溢出信息。
再记录更多事件。
足 24 小时的电量。
2024年11月1日发(作者:禽沛岚)
Cable and Board Presence -
Message Code:
"x1Axx"
Message
Code
E1A10
E1A11
E1A12
E1A14
E1A15
E1A16
E1A17
E1A18
Message
String
PDBPwrCable
PCIRsrConfig
PCIRsrMissing
SAS Cable A
SAS Cable B
SAS Cable FB
PwrCable FB
PDBCtrl Cable
Message Priority
High
High
High
Low
Low
Low
Low
High
Message Comments
PDB power cable to the planar is missing or bad
and system will not power on.
PCI risers are not configured correctly; some
invalid configurations prevent system power on.
One or all of the PCI risers is missing. This
prevents system power on.
SAS cable A is missing or bad.
SAS cable B is missing or bad.
Flex bay SAS cable is missing or bad.
Flex bay power cable is missing or bad.
PDB control cable to the planar is missing or bad
and system will not power on.
Temperature -
Message Code:
"x11xx"
Message
Code
E1114
Message
String
Temp Ambient
Message Priority
Med
Message Comments
Ambient temperature has a reached a point
outside of the allowed range.
Memory has exceeded allowable temperature
E1116Temp MemoryHighand has been disabled to prevent damage to the
components.
Voltages -
Message Code:
"x12xx"
Message
Code
E1210
Message
String
CMOSBatt
Message Priority
Low
Message Comments
CMOS battery is missing or the voltage is outside
of the allowable range.
PERC5I RAID battery charger has reported to the
Server Management that the battery is either
E1211ROMBBattLowmissing, can't charge the battery (possibly
because of high temperatures), or the battery is
bad.
This is a predictive failure warning message
W1228
ROMBBatt<
24 hr
telling the user that the PERC5I RAID battery has
Lowless then 24 hours of charge left init. We provide
this message as a warning message to the
customer.
E1214
E1215
E1216
E1217
E1218
E1219
E1221
1.5VPwrGd
1.8VPwrGd
3.3VPwrGd
5VPwrGd
PCIRsr5VPwr
Gd
BackplanePwr
Gd
Flex
BayPwrGd
High
High
High
High
High
High
High
1.5 VV voltage regulator has failed.
1.8 VV voltage regulator has failed.
3.3 V voltage regulator has failed.
5 V voltage regulator has failed.
PCI Riser 5 V voltage regulator has failed.
Backplane voltage regulator has failed.
Flex Bay voltage regulator power good has failed.
E1222
E1223
E1225
E1226
VCACHE
#PwrGd
VRM #PwrGd
ESB
1.5VPwrGd
PCIRsr1.5VPw
rGd
LinearPwrGd
0.9VPwrGd
CPU #
VCORE
CPU
VTTPwrGd
0.9 V Over
Voltage
CPU Power
Fault
Message
String
RPM Fan ##
RPM Fan Mod
#A
RPM Fan Mod
#B
RPM Fan Mod
#C
RPM Fan Mod
#D
Fan
Redundancy
High
High
High
High
VCACHE # voltage regulator has failed.
VRM # voltage regulator has failed.
ESB 1.5 VV voltage regulator has failed.
PCI Riser 1.5 VV voltage regulator has failed.
Linear voltage regulator(s) has failed. Represents
E1227
E1228
E1229
E122A
E122B
E122C
High
High
High
High
High
High
status of multiple voltage regulators used in the
video and LOM circuitry.
Memory VTT voltage regulator has failed.
Processor # VCORE voltage regulator has failed.
Processor VTT voltage regulator has failed.
0.9 V regulator voltage has exceeded the
allowable voltage range.
A voltage regulator failure was detected when the
processor regulator(s) was enabled.
Fans -
Message Code:
"x13xx"
Message
Code
E1310
E1311
E1311
E1311
E1311
Message Priority
Low
Low
Low
Low
Low
Message Comments
RPM of fan ## is outside of the intended
operating range.
RPM of fan A in the # module is outside of the
intended operating range.
Same as above except for fan B of module #.
Same as above except for fan C of module #.
Same as above except for fan D of module #.
The system is no longer fan redundant. Another
E1313Lowfan failure would put the system at risk of over-
heating.
Processors -
Message Code:
"x14xx"
Message
Code
Message
String
Message PriorityMessage Comments
Processor # has had an internal error (IERR), but
E1410CPU # IERRHigh
this does not always mean that CPU is the
problem .There are a large variety of issues that
cause an IERR.
Processor # has encountered a Thermtrip(over-
temperature) event.
Processor # is missing/bad and the system is in
an unsupported configuration.
Processors are not compatible as defined by Dell
.System is in an unsupported configuration.
BIOS has reported a processor protocol error.
E1414
E1418
E141C
E141F
CPU
#Thermtrip
CPU #
Presence
CPU Mismatch
CPU Protocol
High
High
High
High
E1420
E1421
E1422
CPU Bus
PERR
CPU Init
CPU
MachineChk
High
High
High
BIOS has reported a processor bus PERR (parity
error).
BIOS has reported a processor initialization error.
BIOS has reported a machine check error.
System Memory -
Message Code:
"x21xx"
Message
Code
Message
String
MBECrdx
DIMM ## & ##
Message PriorityMessage Comments
One of the DIMMs in the set implicated by "## &
E2110High
##" has had a multi-bit error (MBE).If no memory
riser is present the “Crdx” string is left out of the
message.“x” is the memory riser, A-Z.
BIOS has disabled memory single-bit error (SBE)
SBE Log
E2111DisableCrdx
DIMM ##
High
logging and will not log anymore SBEE's until the
system is rebooted.## represents DIMM
implicated by BIOS .If no memory riser is present
the “Crd x” string is left out of the message.“x” is
the memory riser, A-Z.
BIOS has spared the memory because it has
E2112
MemSpareCrd
x DIMM ##
determined the memory had too many errors.##
Highrepresents DIMM implicated by BIOS. If no
memory riser is present the “Crdx” string is left
out of the message.“x” is the memory riser, A-Z.
BIOS has disabled memory mirroring because it
Mem Mirror
E2113Crd x DIMM
## & ##
High
has determined one half of the mirror has had too
many errors. ## & ## represents DIMM pair
implicated by BIOS. If no memory riser is present
the “Crdx” string is left out of the message.“x” is
the memory riser, A-Z.
I2114
I2115
I2116
E2117
MemRaid
MemAdded
Card x
MemRemoved
MemHot Plug
Low
Low
Low
Low
BIOS Memory RAID Bank
Memory has been added while the system is
running.
Memory has been removed while the system is
running.
Memory hot-plug operation has failed.
Northbound FBD CRC error on non-redundant
entry. One of the connections in the FBD link on
E2118
Fatal
NBMemCRC
High
the Northbound (towards the MCH) side is
"broken".This is determined by the MCH when
two CRC errors have been detected twice in a
row.
FBD alert on non-redundant entry. One of the
connections in the FBD link on the Southbound
E2119
Fatal
SBMemCRC
High
(towards the AMB'son the FBDIMM's) side is
"broken".This is determined by the MCH when
two CRC errors have been detected twice in a
row.
DELL服务器LCD信息代码的所
錯誤代碼故障硬件相關說明
E1114
E1116
E1210
E1211
E12nn
E1229
E122B
E122C
E1310
E1410
E1414
E1418
E141C
E141F
E1420
E1421
E1422
E1618
E161C
E1620
E1710
E1711
E1712
E1714
E171F
Temp Ambient
Temp Memory
CMOS Batt
ROMB Batt
XX PwrGd
CPU # VCORE
0.9V Over Voltage
CPU Power Fault
RPM Fan ##
CPU # IERR
CPU # Thermtrip
CPU # Presence
CPU Mismatch
CPU Protocol
CPU Bus PERR
CPU Init
E1422
E1618
PS # Input Lost
PS # Input Range
I/O Channel Chk
PCI PERR B## D## F##
PCI PERR Slot #
PCI SERR B## D## F##
PCI SERR Slot #
Unknown Err
PCIE Fatal Err B## D## F##
PCIE Fatal Err Slot #
E1913
E2010
E2011
E2012
E2013
E2014
E2015
E2016
E2017
E2018
E2019
E201A
E201B
E201C
系统周围环境温度超出允许范围。
内存已超过允许温度,系统已将其禁用以防止损坏组件。
缺少 CMOS 电池,或电压超出允许范围。
RAID 电池丢失、损坏或因温度问题而无法再充电。
指定的稳压器出现故障。
处理器 # VCORE 稳压器出现故障。
0.9 V 稳压器电压已超过电压允许范围
启动处理器稳压器之后,检测到稳压器故障
指定的冷却风扇的 RPM 超出允许的运行范围。
指定的微处理器正在报告系统错误。
指定的微处理器超出了允许的温度范围并已停止运行。
指定的处理器丢失或损坏,系统的配置不受支持。
处理器的配置不受 Dell 支持。
系统 BIOS 已报告处理器协议错误。
系统 BIOS 已报告处理器总线奇偶校验错误。
系统 BIOS 已报告处理器初始化错误。
系统 BIOS 已报告机器检查错误。
电源设备电压超出允许范围;指定的电源设备安装错误或出现故障。
指定的电源设备的电源不可用,或超出了允许范围。
指定的电源设备的电源不可用,或超出了允许范围。
系统 BIOS 已报告 I/O 通道检查错误。
系统 BIOS 已报告组件的 PCI 奇偶校验错误,该组件所在的 PCI 配置空
系统 BIOS 已报告组件的 PCI 奇偶校验错误,该组件位于 PCI 插槽 #。
系统 BIOS 已报告组件的 PCI 系统错误,该组件所在的 PCI 配置空间位
系统 BIOS 已报告组件的 PCI 系统错误,该组件位于插槽 #。
系统 BIOS 已确定系统中存在错误,但无法确定错误来源。
系统 BIOS 已报告组件的 PCIe 致命错误,该组件所在的 PCI 配置空间
系统 BIOS 已报告组件的 PCIe 致命错误,该组件位于插槽 #。
卸下并重置 PCI 扩充卡。如果问题仍然存在,请参阅排除扩充卡故障
CPU & Firmware Mismatch
BMC 固件不支持 CPU。
No Memory
系统中没有安装内存。
Mem Config Err
检测到内存,但是内存不可配置。配置内存期间检测到错误。
Mem Mirror DIMM ## & ##
已配置内存,但内存不可用。内存子系统
Shadow BIOS Fail
系统 BIOS 无法将其快擦写映像复制到内存中。
CMOS Fail
CMOS 出现故障。CMOS RAM 未正常工作。
DMA Controller
DMA 控制器出现故障。
Int Controller
中断控制器出现故障。
Timer Fail
计时器刷新故障。
Prog Timer
可编程间隔计时器错误。
Parity Error
奇偶校验错误。
SIO Err
SIO 出现故障。
Kybd Controller
键盘控制器出现故障。
SMI Init
系统管理中断 (SMI) 初始化失败。
E201D
E201E
E201F
E2020
E2021
E2022
E2110
E2111
E2112
E2113
Shutdown Test
BIOS 关闭系统检测失败。
POST Mem Test
BIOS POST 内存检测失败。
DRAC Config
Dell 远程访问控制器 (DRAC) 配置失败。
CPU Config
CPU 配置失败。
Memory Population
内存配置不正确。内存安装顺序不正确。
POST Fail
视频后出现一般故障。
MBE DIMM ## & ##
“## & ##”指示的 DIMM 组中的一个 DIMM 发生内存多位错误 (MBE)
SBE Log Disable DIMM ##
系统 BIOS 已禁用内存单位错误 (SBE) 记录,在重新引导系统之前,不
Mem Spare DIMM ##
系统 BIOS 确定内存中有太多错误,因此已将内存释放。“## & ##”表
Mem Mirror DIMM ## & ##
系统 BIOS 确定一半镜像中有太多错误,因此已将内存禁用。“## &
E2118
E2119
I1910
I1911
I1912
W1228
Fatal NB Mem CRC
北侧的全缓冲 DIMM (FBD) 内存子系统链接中的一个连接失败。
Fatal SB Mem CRC
南侧的 FBD 内存子系统链接中的一个连接失败。
Intrusion
主机盖被卸下。
>3 ERRs Chk Log
LCD 溢出信息。
LCD 上最多只能按顺序显示三条错误信息。第四条信息显示为标准的
SEL Full
系统事件日志中的事件已满,无法再记录更多事件。
ROMB Batt < 24hr
预先警告 RAID 电池只剩下不足 24 小时的电量。
Message Code:
"x1Axx"
Minimum Action Required to Remove
Message from LCD
Failing device is reseated/replaced/repaired.
Failing device is reseated/replaced/repaired.
Failing device is reseated/replaced/repaired.
Failing device is reseated/replaced/repaired.
Failing device is reseated/replaced/repaired.
Failing device is reseated/replaced/repaired.
Failing device is reseated/replaced/repaired.
Failing device is reseated/replaced/repaired.
Exists in
SEL?
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
System Phase When
Event Can Occur?
Pre-Post
Pre-Post
Pre-Post
Any
Any
Any
Any
Any
Message Code:
"x11xx"
Minimum Action Required to Remove
Message from LCD
Temperature returns to allowable range.
Exists in
SEL?
Yes
System Phase When
Event Can Occur?
Any
AC Cycle or SEL clearYesAny
Message Code:
"x12xx"
Minimum Action Required to Remove
Message from LCD
Failing device is reseated/replaced/repaired.
Exists in
SEL?
Yes
System Phase When
Event Can Occur?
Any
Failing device is reseated/replaced/
Battery charges to > 24 hours of sustained
charge.
YesAny
AC Cycle or SEL clear
AC Cycle or SEL clear
AC Cycle or SEL clear
AC Cycle or SEL clear
AC Cycle or SEL clear
AC Cycle or SEL clear
AC Cycle or SEL clear
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Any
Any
Any
Any
Any
Any
Any
AC Cycle or SEL clear
AC Cycle or SEL clear
AC Cycle or SEL clear
AC Cycle or SEL clear
Yes
Yes
Yes
Yes
Any
Any
Any
Any
AC Cycle or SEL clear
AC Cycle or SEL clear
AC Cycle or SEL clear
AC Cycle or SEL clear
AC Cycle or SEL clear
AC Cycle or SEL clear
Yes
Yes
Yes
Yes
Yes
Yes
Any
Any
Any
Any
Any
Any
ssage Code:
"x13xx"
Minimum Action Required to Remove
Message from LCD
Fan RPM reading returns to a point inside of
the intended operating range.
Fan RPM reading returns to a point inside of
the intended operating range.
Fan RPM reading returns to a point inside of
the intended operating range.
Fan RPM reading returns to a point inside of
the intended operating range.
Fan RPM reading returns to a point inside of
the intended operating range.
Fan redundancy is regained, which requires
all fans to be operating within the intended
operating range.
YesAny
Exists in
SEL?
Yes
Yes
Yes
Yes
Yes
System Phase When
Event Can Occur?
Any
Any
Any
Any
Any
Message Code:
"x14xx"
Minimum Action Required to Remove
Message from LCD
Exists in
SEL?
System Phase When
Event Can Occur?
AC Cycle or SEL clearYesAny
AC Cycle or SEL clear
AC Cycle or SEL clear
AC Cycle or SEL clear
AC Cycle or SEL clear
Yes
Yes
Yes
Yes
Any
Pre-POST
Pre-POST
POST, After POST
AC Cycle or SEL clear
AC Cycle or SEL clear
AC Cycle or SEL clear
Yes
Yes
Yes
POST, After POST
POST, After POST
POST, After POST
Message Code:
"x21xx"
Minimum Action Required to Remove
Message from LCD
Exists in
SEL?
System Phase When
Event Can Occur?
AC Cycle or SEL clearYesPOST, After POST
System resetYesPOST, After POST
System resetYesPOST, After POST
System resetYesPOST, After POST
User action, sensor return to normal
AC Cycle or SEL clear
AC Cycle or SEL clear
AC Cycle or SEL clear
Yes
Yes
Yes
Yes
Any
Any
Any
Any
AC Cycle or SEL clearYesPOST, After POST
AC Cycle or SEL clearYesPOST, After POST
码的所代表的含義
禁用以防止损坏组件。
出允许范围。
度问题而无法再充电。
压器故障
允许的运行范围。
范围并已停止运行。
系统的配置不受支持。
奇偶校验错误。
的电源设备安装错误或出现故障。
用,或超出了允许范围。
用,或超出了允许范围。
奇偶校验错误,该组件所在的 PCI 配置空间位于总线 ##,设备 ##,功能 ##。
奇偶校验错误,该组件位于 PCI 插槽 #。
系统错误,该组件所在的 PCI 配置空间位于总线 ##,设备 ##,功能 ##。
系统错误,该组件位于插槽 #。
错误,但无法确定错误来源。
致命错误,该组件所在的 PCI 配置空间位于总线 ##,设备 ##,功能 ##。
致命错误,该组件位于插槽 #。
果问题仍然存在,请参阅排除扩充卡故障。
配置内存期间检测到错误。
。内存子系统出现故障。
像复制到内存中。
未正常工作。
配置失败。
正确。
的一个 DIMM 发生内存多位错误 (MBE)。
误 (SBE) 记录,在重新引导系统之前,不会再记录更多的 SBE。“##”表示 BIOS 指示的 DIMM。
错误,因此已将内存释放。“## & ##”表示 BIOS 指示的 DIMM 对。
太多错误,因此已将内存禁用。“## & ##”表示 BIOS 指示的 DIMM 对。
存子系统链接中的一个连接失败。
中的一个连接失败。
三条错误信息。第四条信息显示为标准的溢出信息。
再记录更多事件。
足 24 小时的电量。