博世B6512 B5512 B4512 B351控制面板快速安装指南说明书

IT圈 admin 11浏览 0评论

2024年11月5日发(作者:笃代秋)

B Series Control Panel

Installer Quick Start Guide

Use this guide to quickly install a Bosch B6512/B5512/B4512/B3512 security system. Additional information is found in the Control Panels Installation Manual.

When you see this icon, use your smart phone with

a QR code reader app to view helpful videos.

Control panel component layoutControl panel connection location

LocationItem

MODULE 1

ETHERNET

USB

Reset

B C

TMPR

Description

Plug-in comm

module

Ethernet port

USB port

Heartbeat LED

Reset switch

Outputs B(2) C(3)

Tamper

Specification

Communication module options

built-in on-board Ethernet connection (10Base-T/100Base-T)

USB connector (for firmware updates and RPS connection)

Slow=normal, rapid=service mode

Hold five seconds to enter or exit service mode

Open collector, 50mA, active low

Optional tamper switch connector (ICP-EZTS)

End Of Line (EOL) resistor supervised alarm inputs

SDI2 device bus

12 VDC, 800mA

Programmable relay output

Primary/Secondary power and Earth Ground connections

Mounting holes for control panel

For additional training:

Bosch YouTube channel:

B Series Installer's Site:

A

A

B

B

1. Scan QR code.

2. Scroll down.

3. Locate and select your region

for additional videos.

(North America only)

C

D

E

F

G

H

I

J

K

L

M

M

C

D

E

F

G

1 COM 2 to

Alarm inputs

7 COM 8

R Y G B

COM AUX

NO C NC

+ BAT –

18 VAC,

Mounting

SDI2 bus

Aux power

Output A(1)

Battery, Earth

ground, 18 VAC

Mounting holes

Installation

sequence:

Scan and follow these

videos in sequential order

to the steps listed below.

LKJIH

Step 1

Bosch tips:

Mounting the control panel

M

Step 2

Bosch tips:

Installing a communication module

A

Step 3

Bosch tips:

Installing a keypad

I

▶ Mount the enclosure prior to mounting the control panel.

▶ Mount control panel into enclosure with hardware provided.

B10

▶ Insert leg of module into slot marked “x.”

▶ Cellular: Place antenna on top of enclosure and run cable inside,

then connect to module.

▶ PSTN: Connect module to a D166 (RJ31x) jack using a D161/D162

cable.

▶ When installing a compatible Bosch keypad, refer to keypad

installation guide for specific wiring diagrams. Basic keypad wiring

is shown below.

▶ When installing more than one keypad, refer to keypad

installation guide for unique address settings.

B11

7 COM 8

Step 4

Bosch tips:

Installing expansion modules

I

Step 5

Bosch tips:

Installing wired inputs

H

Step 6

Bosch tips:

Installing a bell or siren

JK

▶ If installing more than one device that is similar, refer to the

module’s installation guide for address settings (for example,

two of the same device).

▶ If installing a RADION B810 wireless receiver, use address 1 only.

R

E

S

E

T

▶ If using a dual EOL, 2K EOL, or no EOL, refer to control panel

installation guide for control panel settings.

▶ If using 2-wired powered devices, use a B201 or D125B.

NOTE: Not all

modules are available

in all regions.

R

E

S

E

T

▶ Output A can supply up to 1 A at 12 VDC when sourced from a

control panel (jumper in AUX PWR position).

▶ Output A can support up to 3 amps at 12 VDC when using a

separate power supply (jumper in DRY position).

B

C

O

U

T

P

U

T

T

M

P

R

7 COM 8

7 COM 8

C

COM AUX R Y G B

PWR A B COM

A

1 COM 23 COM 45 COM 67 COM 8

C

COM AUX R Y G B

PWR A B COM

A

1 COM 23 COM 45 COM 67 COM 8

T

M

P

R

B

C

O

U

T

P

U

T

▶ Output B and C are open collectors and are limited to 50 mA at

12 VDC.

NC

R

Y

G

B

R

Y

G

B

EOL

NO

+

Step 7

Bosch tips:

k

Powering the control panel

L

Step 8

Bosch tips:

Create panel accounts using RPS

Step 9

Bosch tips:

Connecting the control panel using RPS

BC

▶ Connect wires to control panel before applying battery or AC

power.

▶ Connect earth ground to a cold water pipe (copper) or other

solid connection to ground.

▶ If configuring using the Installer Services Portal, go to Step 11.

▶ Install Remote Programming Software (RPS) v6.06 or later. You can

download RPS from the RPS product page.

▶ Follow the RPS Account Assistant instructions to create new control

panel accounts. The Account Assistant helps you create a new panel

account.

▶ If RPS is not available, keypad programming is an option. Refer to

keypad installation instructions.

▶ Connect a computer with RPS installed. Direct RPS connections

can be done through a USB connection or Ethernet connection.

▶ The Account Assistant automatically launches when you create a

new account.

▶ For USB direct connection, use a B99 USB cable.

R

E

S

E

T

E

T

H

E

R

N

E

T

B Series Control Panel

Installer Quick Start Guide

Step 10

Bosch tips:

Configure and send to control panel using RPS

Step 11a

Bosch tips:

Accessing the Installer Service Portal

and create panel account

Step 11b

Bosch tips:

Connect and send using the Installer

Service Portal

▶ Program your configuration information using Account Assistant.

1. Press close Account Assistant, and connect to control panel. This

opens the Panel Communication window.

2. Press Connect and send configuration programming to control panel.

Using the Installer Services Portal:

(Not in all regions)

Using the Installer Services Portal:

▶ Search or select device to connect to a control panel. Type in panel

account name in the Search field to locate new account.

1. Select the panel account.

2. Click Connect.

3. Click Configuration. Program your

configuration information.

4. Click the 3 vertical dots and select

Push Pending Changes to Panel to

send configuration.

5. Click Disconnect when

configuration is complete.

▶ Before you can use Installer Services Portal you must register for

services at: .

▶ Make sure the control panel is connected to the network.

1. Log into the Installer Services Portal.

2. Click on New and select Device to create a panel account.

3. Add panel account information.

4. Activate CloudID. ISP searches database for registered ID.

5. Select Activate.

6. Click Add Panel.

3. Press Disconnect from control panel when

programming is complete. Go to Step 12.

B Series control panel accessories (partial list)

Note: Not all products and features are available in all regions. Consult your Bosch representative or product datasheets for details.

Step 12

Communicators

Test the system

Control panelPower

B520 AUX Power Supply *TR1850

18 VAC

Transformer

*CX4010

18 VAC

Transformer

After system installation and control panel programming, you

must perform a complete system test. A complete system test

includes testing the control panel, all devices, and communication

destinations for proper operation.

B430 Telephone

B442 Cellular

B443 Cellular (HSPA+

(PSTN)

(GPRS SIM Required)

SIM Required)

Bosch tips:

▶ Perform a Walk Test

1. Select Actions.

2. Select Test.

3. Select Walk Test.

4. Choose a test to run.

▶ Send a test report

(B942 is keypad shown)

Test Menu

Walk Test

Test Report

Revisions

Notification Test

*DE-45-18

18 VAC Transformer

D126

7Ah Battery

D1218

18Ah Battery

B444 Cellular

(Verizon LTE, hot

SIM Required)

B444-V Cellular

(Verizon LTE)

B444-A Cellular

(AT&T LTE)

D135A Low-Battery

Disconnect Module

*Country specific, variants will apply

(Not in all regions)

(Not in all regions)

B450 Remote Cellular Interface

RADION wireless devices

-A versions of RADION devices are used in North and South America.

Non -A versions are used in Europe, Africa, and Australia.

Keypads

B942

Touch Screen

B942W

Touch Screen

B940W

Touch Screen

Residential fire

D132A

Reversing Relay

D125B Dual Class B D192G Bell Super

Initiating ModuleVision Module

FAQs

What is my default code?

User Code: 123456

Installer Code: 123

How do I use Output B and C?

Outputs B and C are Open Collector Outputs. Wiring can be

found in control panel installation manual, section heading Open

Collector Outputs.

How do you remotely turn on and turn off the control panel?

This can be done through the use of the Remote Security Control

App.

B810 SDI2 Wireless Receiver

RFRP Wireless Repeater

RFPR–C12

Curtain PIR,

Pet Immune

40 x 5 ft.

RFDL–11

PIR Microwave

TriTech

35 x 25 ft.

RFPR–12

PIR, Pet

Immune

40 ft.

RFGB

Glass

Break

Detector

(Not in all regions)

(Not in all regions)

B930 Text w/

Soft Keys

B921C

Capacitive Touch

B920 Text w/

Function Keys

B201 2–wire

powered loop

F220/F220–B6R

Smoke Detector

plus Base

(Not in all regions)

RFDW–RM

Recessed Door/

Window Contact

RFDW–SM

Surface Mount

Door/Window

Contact

RFUN Universal

Transmitter w/

Door/Window

Contact

(Not in all regions)

(Not in all regions)

B915 Text

How do I connect directly to the control panel with Ethernet?

Access

modules

B901 Access Module

(B6512 only)

B915I Text

I/O expansion modules

B208 Octo-

Input Module

B308 Octo-

Output Module

By default, the control panel is set up to auto detect and negotiate

a connection to RPS when an ethernet cable is connected between

them.

What do I need to be able to send personal notifications?

SMS (Text) messages require the use of a cellular module and

emails can be sent by either an Ethernet or Cellular connection.

How do I enter “Service Mode”?

Press and hold the yellow reset button on the control panel for 5

seconds (repeat to exit).

RFID tags

(for Readers & B942 Keypads)

RFSM

Wireless

Smoke

Detector

RFBT RFPB–SB

Billtrap

RFPB–TB

Transmitter 1 & 2 Button

Panic

RFKF–TBS

RFKF–FBS

2 & 4 Button

Keyfobs

ACA–ATR13ACD–ATR11ISOACD–ATR14CS

*Home automation

IP camera integration

Any Bosch IP camera

G450 Z-Wave

Home Control Gateway

Remote Security Plus

Mobile App

Where can I go for additional information?

*Home automation may not be available in all regions.

Consult your Bosch representative for details.

Inovonics wireless devices

B820

Wireless Interface

EN4200

Serial Receiver

Enclosures & accessories

B11 Small

Enclosure

(Not in all regions)

(Not in all regions)

D138

Mounting

Bracket

Right Angle

B10 Medium

Enclosure

D137

Mounting

Bracket

Wired motion detectors

Commercial Series

ISC–CDL1–W15x

TriTech

50 ft.

(Not in all regions)

Programing and software

D5500CUB99

Remote Security

Installer Services

RPS Upgrade USB Cable

Control

Portal

Mobile App

ISC–CDL1–WA15x

TriTech+ w/Anti-Mask

50 ft.

(Not in all regions)

Bosch Security Systems B.V.

Torenallee 49

5617 BA Eindhoven

Netherlands

ICP–EZTS

Universal

Tamper

B56 Keypad

Backbox

D101 Lock and

Key set

Blue Line Gen2 Series

ISC–BDL2–WP12G/

WP6G/W12G TriTech

40 X 40 ft./20 x 20

ft./ 40 x 40 ft.

Classic Series

DS9370/

DS9371

360

TriTech

70 ft.

FAQs

(Not in all regions)

© Bosch Security Systems B.V., 2019 Modifications reserved F.01U.324.620 | 04 | 2019.09

2024年11月5日发(作者:笃代秋)

B Series Control Panel

Installer Quick Start Guide

Use this guide to quickly install a Bosch B6512/B5512/B4512/B3512 security system. Additional information is found in the Control Panels Installation Manual.

When you see this icon, use your smart phone with

a QR code reader app to view helpful videos.

Control panel component layoutControl panel connection location

LocationItem

MODULE 1

ETHERNET

USB

Reset

B C

TMPR

Description

Plug-in comm

module

Ethernet port

USB port

Heartbeat LED

Reset switch

Outputs B(2) C(3)

Tamper

Specification

Communication module options

built-in on-board Ethernet connection (10Base-T/100Base-T)

USB connector (for firmware updates and RPS connection)

Slow=normal, rapid=service mode

Hold five seconds to enter or exit service mode

Open collector, 50mA, active low

Optional tamper switch connector (ICP-EZTS)

End Of Line (EOL) resistor supervised alarm inputs

SDI2 device bus

12 VDC, 800mA

Programmable relay output

Primary/Secondary power and Earth Ground connections

Mounting holes for control panel

For additional training:

Bosch YouTube channel:

B Series Installer's Site:

A

A

B

B

1. Scan QR code.

2. Scroll down.

3. Locate and select your region

for additional videos.

(North America only)

C

D

E

F

G

H

I

J

K

L

M

M

C

D

E

F

G

1 COM 2 to

Alarm inputs

7 COM 8

R Y G B

COM AUX

NO C NC

+ BAT –

18 VAC,

Mounting

SDI2 bus

Aux power

Output A(1)

Battery, Earth

ground, 18 VAC

Mounting holes

Installation

sequence:

Scan and follow these

videos in sequential order

to the steps listed below.

LKJIH

Step 1

Bosch tips:

Mounting the control panel

M

Step 2

Bosch tips:

Installing a communication module

A

Step 3

Bosch tips:

Installing a keypad

I

▶ Mount the enclosure prior to mounting the control panel.

▶ Mount control panel into enclosure with hardware provided.

B10

▶ Insert leg of module into slot marked “x.”

▶ Cellular: Place antenna on top of enclosure and run cable inside,

then connect to module.

▶ PSTN: Connect module to a D166 (RJ31x) jack using a D161/D162

cable.

▶ When installing a compatible Bosch keypad, refer to keypad

installation guide for specific wiring diagrams. Basic keypad wiring

is shown below.

▶ When installing more than one keypad, refer to keypad

installation guide for unique address settings.

B11

7 COM 8

Step 4

Bosch tips:

Installing expansion modules

I

Step 5

Bosch tips:

Installing wired inputs

H

Step 6

Bosch tips:

Installing a bell or siren

JK

▶ If installing more than one device that is similar, refer to the

module’s installation guide for address settings (for example,

two of the same device).

▶ If installing a RADION B810 wireless receiver, use address 1 only.

R

E

S

E

T

▶ If using a dual EOL, 2K EOL, or no EOL, refer to control panel

installation guide for control panel settings.

▶ If using 2-wired powered devices, use a B201 or D125B.

NOTE: Not all

modules are available

in all regions.

R

E

S

E

T

▶ Output A can supply up to 1 A at 12 VDC when sourced from a

control panel (jumper in AUX PWR position).

▶ Output A can support up to 3 amps at 12 VDC when using a

separate power supply (jumper in DRY position).

B

C

O

U

T

P

U

T

T

M

P

R

7 COM 8

7 COM 8

C

COM AUX R Y G B

PWR A B COM

A

1 COM 23 COM 45 COM 67 COM 8

C

COM AUX R Y G B

PWR A B COM

A

1 COM 23 COM 45 COM 67 COM 8

T

M

P

R

B

C

O

U

T

P

U

T

▶ Output B and C are open collectors and are limited to 50 mA at

12 VDC.

NC

R

Y

G

B

R

Y

G

B

EOL

NO

+

Step 7

Bosch tips:

k

Powering the control panel

L

Step 8

Bosch tips:

Create panel accounts using RPS

Step 9

Bosch tips:

Connecting the control panel using RPS

BC

▶ Connect wires to control panel before applying battery or AC

power.

▶ Connect earth ground to a cold water pipe (copper) or other

solid connection to ground.

▶ If configuring using the Installer Services Portal, go to Step 11.

▶ Install Remote Programming Software (RPS) v6.06 or later. You can

download RPS from the RPS product page.

▶ Follow the RPS Account Assistant instructions to create new control

panel accounts. The Account Assistant helps you create a new panel

account.

▶ If RPS is not available, keypad programming is an option. Refer to

keypad installation instructions.

▶ Connect a computer with RPS installed. Direct RPS connections

can be done through a USB connection or Ethernet connection.

▶ The Account Assistant automatically launches when you create a

new account.

▶ For USB direct connection, use a B99 USB cable.

R

E

S

E

T

E

T

H

E

R

N

E

T

B Series Control Panel

Installer Quick Start Guide

Step 10

Bosch tips:

Configure and send to control panel using RPS

Step 11a

Bosch tips:

Accessing the Installer Service Portal

and create panel account

Step 11b

Bosch tips:

Connect and send using the Installer

Service Portal

▶ Program your configuration information using Account Assistant.

1. Press close Account Assistant, and connect to control panel. This

opens the Panel Communication window.

2. Press Connect and send configuration programming to control panel.

Using the Installer Services Portal:

(Not in all regions)

Using the Installer Services Portal:

▶ Search or select device to connect to a control panel. Type in panel

account name in the Search field to locate new account.

1. Select the panel account.

2. Click Connect.

3. Click Configuration. Program your

configuration information.

4. Click the 3 vertical dots and select

Push Pending Changes to Panel to

send configuration.

5. Click Disconnect when

configuration is complete.

▶ Before you can use Installer Services Portal you must register for

services at: .

▶ Make sure the control panel is connected to the network.

1. Log into the Installer Services Portal.

2. Click on New and select Device to create a panel account.

3. Add panel account information.

4. Activate CloudID. ISP searches database for registered ID.

5. Select Activate.

6. Click Add Panel.

3. Press Disconnect from control panel when

programming is complete. Go to Step 12.

B Series control panel accessories (partial list)

Note: Not all products and features are available in all regions. Consult your Bosch representative or product datasheets for details.

Step 12

Communicators

Test the system

Control panelPower

B520 AUX Power Supply *TR1850

18 VAC

Transformer

*CX4010

18 VAC

Transformer

After system installation and control panel programming, you

must perform a complete system test. A complete system test

includes testing the control panel, all devices, and communication

destinations for proper operation.

B430 Telephone

B442 Cellular

B443 Cellular (HSPA+

(PSTN)

(GPRS SIM Required)

SIM Required)

Bosch tips:

▶ Perform a Walk Test

1. Select Actions.

2. Select Test.

3. Select Walk Test.

4. Choose a test to run.

▶ Send a test report

(B942 is keypad shown)

Test Menu

Walk Test

Test Report

Revisions

Notification Test

*DE-45-18

18 VAC Transformer

D126

7Ah Battery

D1218

18Ah Battery

B444 Cellular

(Verizon LTE, hot

SIM Required)

B444-V Cellular

(Verizon LTE)

B444-A Cellular

(AT&T LTE)

D135A Low-Battery

Disconnect Module

*Country specific, variants will apply

(Not in all regions)

(Not in all regions)

B450 Remote Cellular Interface

RADION wireless devices

-A versions of RADION devices are used in North and South America.

Non -A versions are used in Europe, Africa, and Australia.

Keypads

B942

Touch Screen

B942W

Touch Screen

B940W

Touch Screen

Residential fire

D132A

Reversing Relay

D125B Dual Class B D192G Bell Super

Initiating ModuleVision Module

FAQs

What is my default code?

User Code: 123456

Installer Code: 123

How do I use Output B and C?

Outputs B and C are Open Collector Outputs. Wiring can be

found in control panel installation manual, section heading Open

Collector Outputs.

How do you remotely turn on and turn off the control panel?

This can be done through the use of the Remote Security Control

App.

B810 SDI2 Wireless Receiver

RFRP Wireless Repeater

RFPR–C12

Curtain PIR,

Pet Immune

40 x 5 ft.

RFDL–11

PIR Microwave

TriTech

35 x 25 ft.

RFPR–12

PIR, Pet

Immune

40 ft.

RFGB

Glass

Break

Detector

(Not in all regions)

(Not in all regions)

B930 Text w/

Soft Keys

B921C

Capacitive Touch

B920 Text w/

Function Keys

B201 2–wire

powered loop

F220/F220–B6R

Smoke Detector

plus Base

(Not in all regions)

RFDW–RM

Recessed Door/

Window Contact

RFDW–SM

Surface Mount

Door/Window

Contact

RFUN Universal

Transmitter w/

Door/Window

Contact

(Not in all regions)

(Not in all regions)

B915 Text

How do I connect directly to the control panel with Ethernet?

Access

modules

B901 Access Module

(B6512 only)

B915I Text

I/O expansion modules

B208 Octo-

Input Module

B308 Octo-

Output Module

By default, the control panel is set up to auto detect and negotiate

a connection to RPS when an ethernet cable is connected between

them.

What do I need to be able to send personal notifications?

SMS (Text) messages require the use of a cellular module and

emails can be sent by either an Ethernet or Cellular connection.

How do I enter “Service Mode”?

Press and hold the yellow reset button on the control panel for 5

seconds (repeat to exit).

RFID tags

(for Readers & B942 Keypads)

RFSM

Wireless

Smoke

Detector

RFBT RFPB–SB

Billtrap

RFPB–TB

Transmitter 1 & 2 Button

Panic

RFKF–TBS

RFKF–FBS

2 & 4 Button

Keyfobs

ACA–ATR13ACD–ATR11ISOACD–ATR14CS

*Home automation

IP camera integration

Any Bosch IP camera

G450 Z-Wave

Home Control Gateway

Remote Security Plus

Mobile App

Where can I go for additional information?

*Home automation may not be available in all regions.

Consult your Bosch representative for details.

Inovonics wireless devices

B820

Wireless Interface

EN4200

Serial Receiver

Enclosures & accessories

B11 Small

Enclosure

(Not in all regions)

(Not in all regions)

D138

Mounting

Bracket

Right Angle

B10 Medium

Enclosure

D137

Mounting

Bracket

Wired motion detectors

Commercial Series

ISC–CDL1–W15x

TriTech

50 ft.

(Not in all regions)

Programing and software

D5500CUB99

Remote Security

Installer Services

RPS Upgrade USB Cable

Control

Portal

Mobile App

ISC–CDL1–WA15x

TriTech+ w/Anti-Mask

50 ft.

(Not in all regions)

Bosch Security Systems B.V.

Torenallee 49

5617 BA Eindhoven

Netherlands

ICP–EZTS

Universal

Tamper

B56 Keypad

Backbox

D101 Lock and

Key set

Blue Line Gen2 Series

ISC–BDL2–WP12G/

WP6G/W12G TriTech

40 X 40 ft./20 x 20

ft./ 40 x 40 ft.

Classic Series

DS9370/

DS9371

360

TriTech

70 ft.

FAQs

(Not in all regions)

© Bosch Security Systems B.V., 2019 Modifications reserved F.01U.324.620 | 04 | 2019.09