最新消息: USBMI致力于为网友们分享Windows、安卓、IOS等主流手机系统相关的资讯以及评测、同时提供相关教程、应用、软件下载等服务。

RM1A, RM1B AC固态继电器 产品说明书

IT圈 admin 28浏览 0评论

2024年2月27日发(作者:府书)

Solid State RelaysIndustrial, 1-Phase ZS (IO) w. LED and Built-in VaristorTypes RM 23, RM 40, RM 48, RM 60RM1A, RM1B• Zero switching (RM1A) or instant-on

switching (RM1B) AC Solid State Relay• Direct copper bonding (DCB) technology• LED indication• Built-in varistor• Clip-on IP 20 protection cover• Self-lifting terminals• Housing free of moulding mass• 2 input ranges: 3-32* VDC and 20-280VAC/22-48VDC• Operational ratings: Up to 100AACrms and 600VACrms• Blocking voltage: Up to 1400Vp• Opto-isolation: > 4000VACrmssProductDescriptionOrdering KeyRM 1 A 23 D 25The industrial, 1-phase relay

The instant-on relay with DC

Solid State Relaywith antiparallel thyristor

control input can be used

Number of polesoutput is the most widely

for phase control. The built-Switching modeused indus trial SSR due

in varistor secures transient

Rated operational voltage

to its multiple application

protection for the heavy

Control voltagepossibilities. The relay

industrial applications, and

Rated operational currentcan be used for resis tive,

the LED indicates the status

inductive and capacitive

of the control input. The

loads. The zero switching

clip-on cover is securing

relay switches ON when the

touch protection to IP 20.

sinusoidal curve crosses zero

Protected output terminals

and switches OFF when the

can handle cables up to

current crosses zero.

SelectionSwitching mode

A: Zero Switching (ZC)

B: Instant-on switching (IO)

Rated operational Control voltage

voltage

23: 230VACrms

40: 400VACrms

48: 480VACrms

60: 600VACrms

A: 20-280VAC / 22-48VDC

D: 3-32VDC*

Rated operational

current25: 25AACrms50: 50AACrms

75: 75AACrms

100: 100AACrms*4 to 32VDC for 400, 480 and 600VAC types

*4 to 32VDC for RM1B types

Selection GuideRated opera- Blocking Control Rated op er a tion al current with suitable heatsink

tional voltage, voltage voltage 25A 50A 75A 100A

Switching mode

230VACrms, 650Vp

ZC

400VACrms, 800Vp

ZC

480VACrms, 1200Vp

ZC

600VACrms, 1400Vp

ZC

3 - 32VDC

20 to 280VAC

22 to 48VDC

4 - 32VDC

20 to 280VAC

22 to 48VDC

4 - 32VDC

20 to 280 VAC

22 to 48VDC

4 - 32VDC

20 to 280VAC

22 to 48VDC

RM1A23D25 RM1A23D50 RM1A23D75 RM1A23D100RM1A23A25 RM1A23A50 RM1A23A75 RM1A23A100

RM1A40D25 RM1A40D50 RM1A40D75 RM1A40D100RM1A40A25 RM1A40A50 RM1A40A75 RM1A40A100

RM1A48D25 RM1A48D50 RM1A48D75 RM1A48D100RM1A48A25 RM1A48A50 RM1A48A75 RM1A48A100RM1A60D25 RM1A60D50 RM1A60D75 RM1A60D100RM1A60A25 RM1A60A50 RM1A60A75 RM1A60A100Specifications are subject to change without notice (31.01.2023)

1

RM1A, RM1BSelection GuideRated opera- Blocking Control Rated op er a tion al current with suitable heatsink

tional voltage, voltage voltage 25A 50A 75A 100A

Switching mode

230VACrms, IO 650Vp 4 - 32VDC

20 - 280VAC/

22 - 48VDC400VACrms, IO 800Vp 4 - 32VDC

480VACrms, IO 1200Vp 4 - 32VDC

600VACrms, IO 1400Vp 4 - 32VDC

20 - 280VAC/

22 - 48VDCRM1B23D25 RM1B23D50 RM1B23D75 RM1B23D100RM1B23A25 RM1B23A50 RM1B23A75 RM1B23A100

RM1B40D25 RM1B40D50 RM1B40D75 RM1B40D100RM1B48D25 RM1B48D50 RM1B48D75 RM1B48D100RM1B60D25 RM1B60D50 RM1B60D75 RM1B60D100

RM1B60A25 RM1B60A50 RM1B60A75 RM1B60A100

Note: For AC control, IO switching part numbers will be created on requestGeneralSpecifications

Operational voltage range

Blocking voltage

Zero voltage turn-on

Operational frequency range

Power factor

Approvals

CE-marking

UKCA Marking

Isolation

Input to Output

input and Output to case

* Heatsink must be connected to 24 to 265VACrms

42 to 265VACrms

650Vp

≤ 10V

45 to 65Hz

> 0.5 @ 230VACrms

UR, cUR, CSA, CCC, EAC

Yes

Yes

4000 Vrms

4000 Vrms

42 to 440VACrms

42 to 440VACrms

800Vp

≤ 10V

45 to 65Hz

> 0.5 @ 400VACrms

UR, cUR, CSA, CCC, EAC

Yes

Yes

4000 Vrms

4000 Vrms

42 to 530VACrms

42 to 530VACrms

1200Vp

≤ 10V

45 to 65Hz

> 0.5 @ 480VACrms

UR, cUR, CSA, CCC, EAC

Yes

Yes

4000 Vrms

4000 Vrms

42 to 660VACrms42 to 660VACrms1400Vp≤ 10V45 to 65Hz> 0.5 @ 600VACrmsUR, cUR, CSA, CCC, EACYes *Yes *

4000 Vrms4000 VrmsInput Specifications

D.. A..

Control voltage range

3 - 32VDC 20 - 280VAC, 22 - 4 - 32VDC 20 - 280VAC, 22 - 4 - 32VDC 20 - 280VAC, 22 - 48VDCPick-up voltage @ Ta = 25˚C

2.5VDC 18VAC/ 3.5VDC 18VAC/DC RM1B ... 3.5VDC 18VAC/DCReverse voltage 32VDC -Drop out voltage 1.2VDC 6VAC/DCInput current @ max input voltage

RM1A ≤12 mA ≤ 20mA RM1B ≤15 mA ≤ 20mAResponse time pick-up

RM1A ≤1/2 cycle ≤ 12ms

RM1B ≤0.1ms ≤ 12msResponse time drop-out

RM1A ≤1/2 cycle ≤ 40ms

RM1B ≤1/2 cycle ≤ 40ms

2

Specifications are subject to change without notice (31.01.2023)

RM1A, RM1BOutput Specifications 100Rated operational current AC51 @ Ta=25°C 25Arms 50Arms 75Arms 100Arms

AC53a @ Ta=25°C 5Arms 15Arms 20Arms 30Arms

Min. operational current 150mA 250mA 400mA 500mARep. overload current t=1 s < 55AACrms < 125AACrms < 150AACrms < 200AACrmsNon-rep. surge current t=10 ms 325Ap 600Ap 1150Ap 1900ApOff-state leakage current @

rated voltage and frequency < 3mArms < 3mArms < 3mArms < 3mArms2222It for fusing t=10 ms < 525As < 1800As < 6600As <18000A2s

Critical dV/dt off-state min. 1000V/µs 1000V/µs 1000V/µs 1000V/µsEndurance testing acc. to UL508 100,000 cycles 100,000 cycles 100,000 cycles 6,000 cyclesNote: UL requirement for General Use Endurance testing is 6,000 cyclesMotor Ratings*: HP (UL508) 230VAC 400VAC 480VAC 600VAC1.5HP 3HP 3HP 5HP3HP 5HP 7.5HP 10HP5HP 10HP 10HP 15HP7.5HP 15HP 20HP 25HPRM1..25

RM1..50

RM1..75

RM1..100

* with suitable heatsinkElectromagnetic CompatibilityEMC Immunity EN60947-4-3

Electrostatic Discharge (ESD)

Immunity IEC/EN 61000-4-2

Air discharge, 8kV Performance Criteria 2 Contact, 4kV Performance Criteria 2Electrical Fast Transient

(Burst) Immunity IEC/EN 61000-4-4

Output: 2kV, 5kHz Performance Criteria 1

Input: 1kV, 5kHz Performance Criteria 1

Electrical Surge Immunity IEC/EN 61000-4-5

Output, line to line, 1kV Performance Criteria 2

Output, line to earth, 2kV Performance Criteria 2

Input, line to line, 1kV

Performance Criteria 2

Input, line to earth, 2kV

Performance Criteria 2

EMC Emission EN60947-4-3Radio Interference

Voltage Emission (Conducted) IEC/EN 55011

0.15 - 30MHz Class A (industrial) with external

filters

Radiated Radio Frequency

Immunity

10V/m, 80 - 1000 MHz

10V/m, 1.4 - 2.0GHz

3 V/m, 2.0 - 2.7GHz

Conducted Radio Frequency

Immunity

10V/m, 0.15 - 80 MHz

Voltage Dips Immunity

0% for 0.5, 1 cycle

40% for 10 cycles

70% for 25 cycles

80% for 250 cycles

Voltage Interruptions Immunity

0% for 5000ms

IEC/EN 61000-4-3

Performance Criteria 1

Performance Criteria 1

Performance Criteria 1IEC/EN 61000-4-6

Performance Criteria 1

IEC/EN 61000-4-11

Performance Criteria 2

Performance Criteria 2

Performance Criteria 2

Performance Criteria 2IEC/EN 61000-4-11

Performance Criteria 2Radio Interference

Field Emission (Radiated)

30 - 1000MHz

IEC/EN 55011

Class B

Specifications are subject to change without notice (31.01.2023)

3

RM1A, RM1BNotes:- Use of AC solid state relays may, according to the application and the load current, cause conducted radio interferences. Use of mains filters may be neces-sary for cases where the user must meet E.M.C requirements. The capacitor values given inside the filtering specification tables should be taken only as indi-cations, the filter attenuation will depend on the final application.- The control terminals A1, A2 (RM1..A) shall be supplied by a secondary circuit where power is limited by a transformer, rectifier, voltage divider, or similar

device that derives power from a primary circuit, and where the short-circuit limit between conductors of the secondary circuit or between conductors and

ground is 1500 VA or less. The short-circuit volt ampere limit is the product of the open circuit voltage and the short circuit ampere.- Control input lines must be installed together to maintain products’ susceptibility to Radio Frequency interference.- Performance Criteria 1: No degradation of performance or loss of function is allowed when the product is operated as intended.- Performance Criteria 2: During the test, degradation of performance or partial loss of function is allowed. However, when the test is complete the product

should return operating as intended by itself.- Performance Criteria 3: Temporary loss of function is allowed, provided the function can be restored by manual operation of the controls.

Housing SpecificationsWeight

25A, 50A

75A, 100A

Baseplate

25A, 50A

75A, 100A

Potting compound

Approx. 60g

Approx. 100gAluminium

Copper, nickel-platedNone

Relay

Mounting screws

Mounting torque

M5

1.5-2.0NmConnection SpecificationsConnection terminals L1, T1 A1, A2Stripping length (X)

Connection Type

Rigid (solid & stranded)

UR rated data

Flexible with end sleeve

X

Flexible without end sleeve

X

X

12 mm 8 mm

M3 screw with captivated washer

XM5 screw with captivated washer

1x 2.5 - 6.0 mm²

1x 14 - 10 AWG

1x 1.0 - 4.0 mm²

1x 18 - 12 AWG

X

1x 1.0 - 6.0 mm²

1x 18 - 10 AWG

2x 2.5 - 6.0 mm²

2x 14 - 10 AWG

2x 1.0 - 2.5 mm²

2x 2.5 - 4.0 mm²

2x 18 - 14 AWG

2x 14 - 12 AWG

2x 1.0 - 2.5 mm²

2x 2.5 - 6.0 mm²

2x 18 - 14 AWG

2x 14 - 10 AWG

X1x 0.5 - 2.5 mm²

1x 18 - 12 AWG

1x 0.5 - 2.5 mm²

1x 18 - 12 AWG

2x 0.5 - 2.5 mm²2x 18 - 12 AWG

2x 0.5 - 2.5 mm²

2x 18 - 12 AWG

X

X

Pozidrive 1

0.5 Nm (4.4 lb-in)

7.5 mm

Torque specification

Aperture for termination lug

Pozidrive 2

12 mm

2.4 Nm (21.2 lb-in)

4

Specifications are subject to change without notice (31.01.2023)

RM1A, RM1BFunctional DiagramDimensions+)A1(~*REGULATIONZCT1ZCIO-)A2(~L1LEDAPPLYHEATSINKCOMPOUND* Varistor across input applies to AC control versions dimensions in mmConnection DiagramL1L2/N*LOAD~( )-* Depends on system requirements

~( )+Control InputOutput Power Dissipation120100RM..100Power

dissipation

in

W80RM..7560RM..50RM.60..5040RM..2523095100Load current per pole in AACrmsSpecifications are subject to change without notice (31.01.2023)

5

RM1A, RM1BHeatsink Dimensions

(load current versus ambient temperature)RM..25Load

current [A]Thermal resistance

[°C/W]25.02.702.341.981.611.250.8922.53.102.692.281.861.451.0420.03.613.132.652.181.701.2317.54.263.703.142.592.031.4715.05.144.473.803.142.471.8012.56.385.564.733.913.092.2710.08.257.196.145.084.022.977.511.49.948.497.045.594.145.017.715.413.211.08.746.512.5----18.213.62TAAmbient temp. [°C] Junction to ambient thermal resistance, Rth j-a < 20.0 °C/W Junction to case thermal resistance, Rth j-c < 0.80 °C/W Case to heatsink thermal resistance, Rth c-s2 < 0.20 °C/W Maximum allowable case temperature 100 °C Maximum allowable junction temperature 125 °CRM1.60..50Load

current [A]Thermal resistance

[°C/W]50.00.990.810.630.440.260.0845.01.281.070.860.650.440.2340.01.641.401.150.910.670.4235.02.111.821.541.250.960.6730.02.602.251.901.551.200.8525.03.302.862.431.991.551.1120.04.363.793.222.652.081.5115.06.15.44.63.772.972.1810.09.768.527.36.04.83.545.0----15.4712.8510.247.62TAAmbient temp. [°C] Junction to ambient thermal resistance, Rth j-a < 20.0 °C/W Junction to case thermal resistance, Rth j-c < 0.72 °C/W Case to heatsink thermal resistance, Rth c-s2 < 0.10 °C/W Maximum allowable heatsink temperature 100 °C Maximum allowable junction temperature 125 °C6

RM..50Load

current [A]Thermal resistance

[°C/W]50.01.030.860.700.530.370.2045.01.271.320.900.710.520.3340.01.541.591.100.890.670.4535.01.851.951.341.080.820.5730.02.262.471.651.341.030.7225.02.853.242.081.701.320.9420.03.733.242.752.261.771.2715.05.224.543.863.192.511.8310.08.217.166.115.054.002.955.017.215.012.910.78.516.332TAAmbient temp. [°C] Junction to ambient thermal resistance, Rth j-a < 20.0 °C/W Junction to case thermal resistance, Rth j-c < 0.50 °C/W Case to heatsink thermal resistance, Rth c-s2 < 0.20 °C/W Maximum allowable case temperature 100 °C Maximum allowable junction temperature 125 °CRM..75Load

current [A]Thermal resistance

[°C/W]75.00.910.780.650.520.390.2667.51.100.960.810.660.510.3660.01.341.171.000.830.660.4952.51.601.401.201.000.800.6045.01.931.681.441.200.960.7237.52.382.081.781.491.190.8930.03.062.682.301.911.531.1522.54.213.683.162.632.101.5815.06.515.704.884.073.262.447.513.511.7710.098.416.735.70TAAmbient temp. [°C] Junction to ambient thermal resistance, Rth j-a < 20.0 °C/W Junction to case thermal resistance, Rth j-c < 0.35 °C/W Case to heatsink thermal resistance, Rth c-s2 < 0.10 °C/W Maximum allowable heatsink temperature 100 °C Maximum allowable junction temperature 125 °CSpecifications are subject to change without notice (31.01.2023)

RM1A, RM1BHeatsink Dimensions

(load current versus ambient temperature) (cont.)RM..100Load

current [A]Thermal resistance

[°C/W]100.090.080.070.060.050.040.030.020.010.00.540.680.861.081.371.702.213.064.789.98200.450.580.740.941.201.491.932.684.188.73300.360.470.620.801.031.281.662.303.597.49400.270.370.500.660.851.061.381.912.996.24500.180.270.380.520.680.851.101.532.394.99600.090.170.260.380.510.640.831.151.793.7470TAAmbient temp. [°C] Junction to ambient thermal resistance, Rth j-a < 20.0

Junction to case thermal resistance, Rth j-c < 0.30

Case to heatsink thermal resistance, Rth c-s2 < 0.10

Maximum allowable heatsink temperature 100

Maximum allowable junction temperature 125

°C/W°C/W°C/W°C°C2. Thermal resistance case to heatsink valves are applicable upon application of a fine layer of silicon based thermal paste HTS02S from Electrolube between

SSR and l Specifications 50 RM1.60.100-20° to 70°C

-40° to 100°C

≤ 125°C

≤ 0.80°C/W

≤ 20.0°C/W

-20° to 70°C

-40° to 100°C

≤ 125°C

≤ 0.50°C/W

≤ 20.0°C/W

-20° to 70°C

-40° to 100°C

≤ 125°C

≤ 0.72°C/W

≤ 20.0°C/W

-20° to 70°C

-40° to 100°C

≤ 125°C

≤ 0.35°C/W

≤ 20.0°C/W

-20° to 70°C-40° to 100°C≤ 125°C≤ 0.30°C/W≤ 20.0°C/WOperating temperature range

Storage temperature range

Junction temperature

Rth junction to case

Rth junction to ambient

Heatsink SelectionOrdering Key• Heatsinks and fans• 5.40oC/W to 0.12oC/W thermal resistance• DIN, panel or thru wall mounting• Single or multiple SSR mountingRHS..Heatsink Range Overview:/images/PIM/DATASHEET/ENG/SSR_tsink Selector Tool:/nsc/hq/en/solid_state_relaysSpecifications are subject to change without notice (31.01.2023)

7

RM1A, RM1BShort Circuit ProtectionProtection Co-ordination, Type 1 vs. Type 2:Type 1 protection implies that after a short circuit, the device under test will no longer be in a functioning state. In type

2 co-ordination the device under test will still be functional after the short circuit. In both cases, however, the short circuit

has to be interrupted. The fuse between enclosure and supply shall not open. The door or cover of the enclosure shall not

be blown open. There shall be no damage to conductors of terminals and the conductors shall not separate from terminals.

Therese shall be no breakage or cracking of insulating bases to the extent that the integrity of the mounting of live parts is

impaired. Discharge of parts or any risk of fire shall not occur.

The product variants listed in the table hereunder are suitable for use on a circuit capable of delivering not more than

65,000A rms Symmetrical Amperes, 600Volts maximum when protected by fuses. Tests at 65,000A were performed with

Class J, fast acting: please refer to the table below for maximum allowed ampere rating of the fuse. Use fuses only.

Co-ordination type 1 (UL508)Part No.

RM1..25..

RM1..50..

RM1..75..

RM1..100..

Prospective short

circuit current [kArms]65

65

65

65

Max. fuse size [A] Class/ Model Voltage [VAC]

30

30

20

80

60

80

60

J or CC

J

HSJ20 (Mersen*)

J

HSJ60 (Mersen*)

J

HSJ60 (Mersen*)

600600

600600

600600

600Co-ordination type 2 (IEC/EN60947-4-3)Part No.

.25.. (xx = 23, 40 or 48)

RM1.60.25..

.50.. (xx = 23 or 40)

.50.. (xx = 48 or 60)

.75.. (xx = 23, 40, 48 or 60)

.100.. (xx = 23, 40, 48 or 60)

zz = 00, without fuse trip indication

zz = 21, with fuse trip indication

* Formerly Ferraz ShawmutProspective short

circuit current [kArms]

10

10

10

10

10

10

Max. fuse Brand

size [A]

25

20

50

50

63

100

Mersen*

Mersen*

Mersen*

Mersen*

Mersen*

Mersen*

Model Size

6.9 gRB 10-25

6.9 gRB 10-20

6.9zz CP gRC 14x51/50

6.9zz CP gRC 22x58/50

6.9zz CP gRC 22x58/63

6.9zz CP gRC 22x58/100

10.3 x 3810.3 x 3814 x 5122 x 5822 x 5822 x 58

8

Specifications are subject to change without notice (31.01.2023)

RM1A, RM1BType 2 Protection with Miniature Circuit Breakers (M.C.B.s)Solid State Relay

type

ABB Model no. for

Z - type M. C. B.

(rated current)

ABB Model no. for

B - type M. C. B.

(rated current)

Wire cross

sectional area [mm2]

Minimum length of

Cu wire conductor [m]*

21.0

21.0

31.5

7.6

11.4

19.0

5.2

7.8

13.0

20.8

12.6

21.0

25.0

40.0

19.0

30.4

4.2

7.0

11.2

13.0

20.8

31.2

1.8

3.0

4.8

5.0

8.0

12.0

20.0

14.8

22.2

37.0

4.8

7.2

12.0

19.2

7.2

12.0

19.2

RM1..25.. 1-pole

S201-Z4 (4A)

S201-Z6 UC (6A)

RM1..50.. 1-pole

S201-Z10 (10A)

S201-Z16 (16A)

S201-Z20 (20A)

S201-Z25 (25A)

2-pole

S202-Z25 (25A)

RM1..75.. 1-pole

S201-Z20 (20A)

S201-Z32 (32A)

2-pole

S202-Z20 (20A)

S202-Z32 (32A)

S202-Z50 (50A)

RM1..100.. 1-pole

S201-Z50 (50A)

S201-Z63 (63A)

S201-B2 (2A) 1.0

S201-B2 (2A) 1.0

1.5

S201-B4 (4A) 1.0

1.5

2.5

S201-B6 (6A) 1.0

1.5

2.5

4.0

S201-B10 (10A) 1.5

2.5

S201-B13 (13A) 2.5

4.0

S202-B13 (13A) 2.5

4.0

S201-B10 (10A) 1.5

2.5

4.0

S201-B16 (16A) 2.5

4.0

6.0

S202-B10 (10A) 1.5

2.5

4.0

S202-B16 (16A) 2.5

4.0

6.0

10.0

S202-B25 (25A) 4.0

6.0

10.0

S201-B25 (25A) 4.0

6.0

10.0

16.0

S201-B32 (32A) 6.0

10.0

16.0

* Between MCB and Load (including return path which goes back to the mains).Note: A prospective current of 6kA and a 230/400V power supply system is assumed for the above suggested specifications. For cables with different cross

section than those mentioned above please consult Carlo Gavazzi’s Technical Support ications are subject to change without notice (31.01.2023)

9

RM1A, RM1BEnvironmental InformationThe declaration in this section is prepared in compliance with People’s Republic of China Electronic Industry Standard SJ/T11364-2014: Marking for the Restricted Use of Hazardous Substances in Electronic and Electrical NameLead(Pb)Power Unit AssemblyxMercury(Hg)OToxic or Harardous Substances and ElementsCadmium(Cd)OHexavalent

Chromium

(Cr(Vl))OPolybrominated

biphenyls (PBB)OPolybrominated

diphenyl ethers

(PBDE)OO: Indicates that said hazardous substance contained in homogeneous materials fot this part are below the limit require-ment of GB/T 26572.X: Indicates that said hazardous substance contained in one of the homogeneous materials used for this part is above the

limit requirement of GB/T 26572.环境特性这份申明根据中华人民共和国电子工业标准SJ/T11364-2014:标注在电子电气产品中限定使用的有害物质零件名称铅(Pb)功率单元x汞(Hg)O镉(Cd)O有毒或有害物质与元素六价铬(Cr(Vl))O多溴化联苯(PBB)O多溴联苯醚(PBDE)OO:此零件所有材料中含有的该有害物低于GB/T 26572的限定。X: 此零件某种材料中含有的该有害物高于GB/T 26572的限定。2510

Specifications are subject to change without notice (31.01.2023)

RM1A, RM1BFASTON terminals

• Faston tabs• Tab dimensions according

to DIN 46342 part 1• Pure tin-plated brassOrdering KeyScrew mounted

Faston terminalsRS, RM Solid State RelayFaston terminalsTab orientationInput Tab width: 4.8mmOutput Tab width: 6.3mmRM1A48D25 F 4*Faston terminals

in packs of 20RS, RM Solid State RelayTab orientation** RM48 F4**0: Flat (0º)4: Angled (45º)** 48: 4.8mm faston for input 63: 6.3mm faston for outputFork Terminals

• Terminal adaptors for 35mm2 cable• Type RM635FK• Pack size: 10 piecesOrdering KeyRM terminal adaptorTouch protected (optional) RM635FK POther Accessories• Graphite thermal pad

with adhesive on one

side• Type KK071CUT• Dimensions: 35 x 43 x

0.25mm• Packing quantity: 50pcs.• Touch safety cover• Type RMIP20• IP20 protection degree• Pack size: 20 piecesAll accessories can be ordered pre-assembled with Solid State accessories include DIN rail adaptors, fuses, varistors and futher information refer to Accessories datasheets at:/images/PIM/DATASHEET/ENG/SSR_cifications are subject to change without notice (31.01.2023)

11

2024年2月27日发(作者:府书)

Solid State RelaysIndustrial, 1-Phase ZS (IO) w. LED and Built-in VaristorTypes RM 23, RM 40, RM 48, RM 60RM1A, RM1B• Zero switching (RM1A) or instant-on

switching (RM1B) AC Solid State Relay• Direct copper bonding (DCB) technology• LED indication• Built-in varistor• Clip-on IP 20 protection cover• Self-lifting terminals• Housing free of moulding mass• 2 input ranges: 3-32* VDC and 20-280VAC/22-48VDC• Operational ratings: Up to 100AACrms and 600VACrms• Blocking voltage: Up to 1400Vp• Opto-isolation: > 4000VACrmssProductDescriptionOrdering KeyRM 1 A 23 D 25The industrial, 1-phase relay

The instant-on relay with DC

Solid State Relaywith antiparallel thyristor

control input can be used

Number of polesoutput is the most widely

for phase control. The built-Switching modeused indus trial SSR due

in varistor secures transient

Rated operational voltage

to its multiple application

protection for the heavy

Control voltagepossibilities. The relay

industrial applications, and

Rated operational currentcan be used for resis tive,

the LED indicates the status

inductive and capacitive

of the control input. The

loads. The zero switching

clip-on cover is securing

relay switches ON when the

touch protection to IP 20.

sinusoidal curve crosses zero

Protected output terminals

and switches OFF when the

can handle cables up to

current crosses zero.

SelectionSwitching mode

A: Zero Switching (ZC)

B: Instant-on switching (IO)

Rated operational Control voltage

voltage

23: 230VACrms

40: 400VACrms

48: 480VACrms

60: 600VACrms

A: 20-280VAC / 22-48VDC

D: 3-32VDC*

Rated operational

current25: 25AACrms50: 50AACrms

75: 75AACrms

100: 100AACrms*4 to 32VDC for 400, 480 and 600VAC types

*4 to 32VDC for RM1B types

Selection GuideRated opera- Blocking Control Rated op er a tion al current with suitable heatsink

tional voltage, voltage voltage 25A 50A 75A 100A

Switching mode

230VACrms, 650Vp

ZC

400VACrms, 800Vp

ZC

480VACrms, 1200Vp

ZC

600VACrms, 1400Vp

ZC

3 - 32VDC

20 to 280VAC

22 to 48VDC

4 - 32VDC

20 to 280VAC

22 to 48VDC

4 - 32VDC

20 to 280 VAC

22 to 48VDC

4 - 32VDC

20 to 280VAC

22 to 48VDC

RM1A23D25 RM1A23D50 RM1A23D75 RM1A23D100RM1A23A25 RM1A23A50 RM1A23A75 RM1A23A100

RM1A40D25 RM1A40D50 RM1A40D75 RM1A40D100RM1A40A25 RM1A40A50 RM1A40A75 RM1A40A100

RM1A48D25 RM1A48D50 RM1A48D75 RM1A48D100RM1A48A25 RM1A48A50 RM1A48A75 RM1A48A100RM1A60D25 RM1A60D50 RM1A60D75 RM1A60D100RM1A60A25 RM1A60A50 RM1A60A75 RM1A60A100Specifications are subject to change without notice (31.01.2023)

1

RM1A, RM1BSelection GuideRated opera- Blocking Control Rated op er a tion al current with suitable heatsink

tional voltage, voltage voltage 25A 50A 75A 100A

Switching mode

230VACrms, IO 650Vp 4 - 32VDC

20 - 280VAC/

22 - 48VDC400VACrms, IO 800Vp 4 - 32VDC

480VACrms, IO 1200Vp 4 - 32VDC

600VACrms, IO 1400Vp 4 - 32VDC

20 - 280VAC/

22 - 48VDCRM1B23D25 RM1B23D50 RM1B23D75 RM1B23D100RM1B23A25 RM1B23A50 RM1B23A75 RM1B23A100

RM1B40D25 RM1B40D50 RM1B40D75 RM1B40D100RM1B48D25 RM1B48D50 RM1B48D75 RM1B48D100RM1B60D25 RM1B60D50 RM1B60D75 RM1B60D100

RM1B60A25 RM1B60A50 RM1B60A75 RM1B60A100

Note: For AC control, IO switching part numbers will be created on requestGeneralSpecifications

Operational voltage range

Blocking voltage

Zero voltage turn-on

Operational frequency range

Power factor

Approvals

CE-marking

UKCA Marking

Isolation

Input to Output

input and Output to case

* Heatsink must be connected to 24 to 265VACrms

42 to 265VACrms

650Vp

≤ 10V

45 to 65Hz

> 0.5 @ 230VACrms

UR, cUR, CSA, CCC, EAC

Yes

Yes

4000 Vrms

4000 Vrms

42 to 440VACrms

42 to 440VACrms

800Vp

≤ 10V

45 to 65Hz

> 0.5 @ 400VACrms

UR, cUR, CSA, CCC, EAC

Yes

Yes

4000 Vrms

4000 Vrms

42 to 530VACrms

42 to 530VACrms

1200Vp

≤ 10V

45 to 65Hz

> 0.5 @ 480VACrms

UR, cUR, CSA, CCC, EAC

Yes

Yes

4000 Vrms

4000 Vrms

42 to 660VACrms42 to 660VACrms1400Vp≤ 10V45 to 65Hz> 0.5 @ 600VACrmsUR, cUR, CSA, CCC, EACYes *Yes *

4000 Vrms4000 VrmsInput Specifications

D.. A..

Control voltage range

3 - 32VDC 20 - 280VAC, 22 - 4 - 32VDC 20 - 280VAC, 22 - 4 - 32VDC 20 - 280VAC, 22 - 48VDCPick-up voltage @ Ta = 25˚C

2.5VDC 18VAC/ 3.5VDC 18VAC/DC RM1B ... 3.5VDC 18VAC/DCReverse voltage 32VDC -Drop out voltage 1.2VDC 6VAC/DCInput current @ max input voltage

RM1A ≤12 mA ≤ 20mA RM1B ≤15 mA ≤ 20mAResponse time pick-up

RM1A ≤1/2 cycle ≤ 12ms

RM1B ≤0.1ms ≤ 12msResponse time drop-out

RM1A ≤1/2 cycle ≤ 40ms

RM1B ≤1/2 cycle ≤ 40ms

2

Specifications are subject to change without notice (31.01.2023)

RM1A, RM1BOutput Specifications 100Rated operational current AC51 @ Ta=25°C 25Arms 50Arms 75Arms 100Arms

AC53a @ Ta=25°C 5Arms 15Arms 20Arms 30Arms

Min. operational current 150mA 250mA 400mA 500mARep. overload current t=1 s < 55AACrms < 125AACrms < 150AACrms < 200AACrmsNon-rep. surge current t=10 ms 325Ap 600Ap 1150Ap 1900ApOff-state leakage current @

rated voltage and frequency < 3mArms < 3mArms < 3mArms < 3mArms2222It for fusing t=10 ms < 525As < 1800As < 6600As <18000A2s

Critical dV/dt off-state min. 1000V/µs 1000V/µs 1000V/µs 1000V/µsEndurance testing acc. to UL508 100,000 cycles 100,000 cycles 100,000 cycles 6,000 cyclesNote: UL requirement for General Use Endurance testing is 6,000 cyclesMotor Ratings*: HP (UL508) 230VAC 400VAC 480VAC 600VAC1.5HP 3HP 3HP 5HP3HP 5HP 7.5HP 10HP5HP 10HP 10HP 15HP7.5HP 15HP 20HP 25HPRM1..25

RM1..50

RM1..75

RM1..100

* with suitable heatsinkElectromagnetic CompatibilityEMC Immunity EN60947-4-3

Electrostatic Discharge (ESD)

Immunity IEC/EN 61000-4-2

Air discharge, 8kV Performance Criteria 2 Contact, 4kV Performance Criteria 2Electrical Fast Transient

(Burst) Immunity IEC/EN 61000-4-4

Output: 2kV, 5kHz Performance Criteria 1

Input: 1kV, 5kHz Performance Criteria 1

Electrical Surge Immunity IEC/EN 61000-4-5

Output, line to line, 1kV Performance Criteria 2

Output, line to earth, 2kV Performance Criteria 2

Input, line to line, 1kV

Performance Criteria 2

Input, line to earth, 2kV

Performance Criteria 2

EMC Emission EN60947-4-3Radio Interference

Voltage Emission (Conducted) IEC/EN 55011

0.15 - 30MHz Class A (industrial) with external

filters

Radiated Radio Frequency

Immunity

10V/m, 80 - 1000 MHz

10V/m, 1.4 - 2.0GHz

3 V/m, 2.0 - 2.7GHz

Conducted Radio Frequency

Immunity

10V/m, 0.15 - 80 MHz

Voltage Dips Immunity

0% for 0.5, 1 cycle

40% for 10 cycles

70% for 25 cycles

80% for 250 cycles

Voltage Interruptions Immunity

0% for 5000ms

IEC/EN 61000-4-3

Performance Criteria 1

Performance Criteria 1

Performance Criteria 1IEC/EN 61000-4-6

Performance Criteria 1

IEC/EN 61000-4-11

Performance Criteria 2

Performance Criteria 2

Performance Criteria 2

Performance Criteria 2IEC/EN 61000-4-11

Performance Criteria 2Radio Interference

Field Emission (Radiated)

30 - 1000MHz

IEC/EN 55011

Class B

Specifications are subject to change without notice (31.01.2023)

3

RM1A, RM1BNotes:- Use of AC solid state relays may, according to the application and the load current, cause conducted radio interferences. Use of mains filters may be neces-sary for cases where the user must meet E.M.C requirements. The capacitor values given inside the filtering specification tables should be taken only as indi-cations, the filter attenuation will depend on the final application.- The control terminals A1, A2 (RM1..A) shall be supplied by a secondary circuit where power is limited by a transformer, rectifier, voltage divider, or similar

device that derives power from a primary circuit, and where the short-circuit limit between conductors of the secondary circuit or between conductors and

ground is 1500 VA or less. The short-circuit volt ampere limit is the product of the open circuit voltage and the short circuit ampere.- Control input lines must be installed together to maintain products’ susceptibility to Radio Frequency interference.- Performance Criteria 1: No degradation of performance or loss of function is allowed when the product is operated as intended.- Performance Criteria 2: During the test, degradation of performance or partial loss of function is allowed. However, when the test is complete the product

should return operating as intended by itself.- Performance Criteria 3: Temporary loss of function is allowed, provided the function can be restored by manual operation of the controls.

Housing SpecificationsWeight

25A, 50A

75A, 100A

Baseplate

25A, 50A

75A, 100A

Potting compound

Approx. 60g

Approx. 100gAluminium

Copper, nickel-platedNone

Relay

Mounting screws

Mounting torque

M5

1.5-2.0NmConnection SpecificationsConnection terminals L1, T1 A1, A2Stripping length (X)

Connection Type

Rigid (solid & stranded)

UR rated data

Flexible with end sleeve

X

Flexible without end sleeve

X

X

12 mm 8 mm

M3 screw with captivated washer

XM5 screw with captivated washer

1x 2.5 - 6.0 mm²

1x 14 - 10 AWG

1x 1.0 - 4.0 mm²

1x 18 - 12 AWG

X

1x 1.0 - 6.0 mm²

1x 18 - 10 AWG

2x 2.5 - 6.0 mm²

2x 14 - 10 AWG

2x 1.0 - 2.5 mm²

2x 2.5 - 4.0 mm²

2x 18 - 14 AWG

2x 14 - 12 AWG

2x 1.0 - 2.5 mm²

2x 2.5 - 6.0 mm²

2x 18 - 14 AWG

2x 14 - 10 AWG

X1x 0.5 - 2.5 mm²

1x 18 - 12 AWG

1x 0.5 - 2.5 mm²

1x 18 - 12 AWG

2x 0.5 - 2.5 mm²2x 18 - 12 AWG

2x 0.5 - 2.5 mm²

2x 18 - 12 AWG

X

X

Pozidrive 1

0.5 Nm (4.4 lb-in)

7.5 mm

Torque specification

Aperture for termination lug

Pozidrive 2

12 mm

2.4 Nm (21.2 lb-in)

4

Specifications are subject to change without notice (31.01.2023)

RM1A, RM1BFunctional DiagramDimensions+)A1(~*REGULATIONZCT1ZCIO-)A2(~L1LEDAPPLYHEATSINKCOMPOUND* Varistor across input applies to AC control versions dimensions in mmConnection DiagramL1L2/N*LOAD~( )-* Depends on system requirements

~( )+Control InputOutput Power Dissipation120100RM..100Power

dissipation

in

W80RM..7560RM..50RM.60..5040RM..2523095100Load current per pole in AACrmsSpecifications are subject to change without notice (31.01.2023)

5

RM1A, RM1BHeatsink Dimensions

(load current versus ambient temperature)RM..25Load

current [A]Thermal resistance

[°C/W]25.02.702.341.981.611.250.8922.53.102.692.281.861.451.0420.03.613.132.652.181.701.2317.54.263.703.142.592.031.4715.05.144.473.803.142.471.8012.56.385.564.733.913.092.2710.08.257.196.145.084.022.977.511.49.948.497.045.594.145.017.715.413.211.08.746.512.5----18.213.62TAAmbient temp. [°C] Junction to ambient thermal resistance, Rth j-a < 20.0 °C/W Junction to case thermal resistance, Rth j-c < 0.80 °C/W Case to heatsink thermal resistance, Rth c-s2 < 0.20 °C/W Maximum allowable case temperature 100 °C Maximum allowable junction temperature 125 °CRM1.60..50Load

current [A]Thermal resistance

[°C/W]50.00.990.810.630.440.260.0845.01.281.070.860.650.440.2340.01.641.401.150.910.670.4235.02.111.821.541.250.960.6730.02.602.251.901.551.200.8525.03.302.862.431.991.551.1120.04.363.793.222.652.081.5115.06.15.44.63.772.972.1810.09.768.527.36.04.83.545.0----15.4712.8510.247.62TAAmbient temp. [°C] Junction to ambient thermal resistance, Rth j-a < 20.0 °C/W Junction to case thermal resistance, Rth j-c < 0.72 °C/W Case to heatsink thermal resistance, Rth c-s2 < 0.10 °C/W Maximum allowable heatsink temperature 100 °C Maximum allowable junction temperature 125 °C6

RM..50Load

current [A]Thermal resistance

[°C/W]50.01.030.860.700.530.370.2045.01.271.320.900.710.520.3340.01.541.591.100.890.670.4535.01.851.951.341.080.820.5730.02.262.471.651.341.030.7225.02.853.242.081.701.320.9420.03.733.242.752.261.771.2715.05.224.543.863.192.511.8310.08.217.166.115.054.002.955.017.215.012.910.78.516.332TAAmbient temp. [°C] Junction to ambient thermal resistance, Rth j-a < 20.0 °C/W Junction to case thermal resistance, Rth j-c < 0.50 °C/W Case to heatsink thermal resistance, Rth c-s2 < 0.20 °C/W Maximum allowable case temperature 100 °C Maximum allowable junction temperature 125 °CRM..75Load

current [A]Thermal resistance

[°C/W]75.00.910.780.650.520.390.2667.51.100.960.810.660.510.3660.01.341.171.000.830.660.4952.51.601.401.201.000.800.6045.01.931.681.441.200.960.7237.52.382.081.781.491.190.8930.03.062.682.301.911.531.1522.54.213.683.162.632.101.5815.06.515.704.884.073.262.447.513.511.7710.098.416.735.70TAAmbient temp. [°C] Junction to ambient thermal resistance, Rth j-a < 20.0 °C/W Junction to case thermal resistance, Rth j-c < 0.35 °C/W Case to heatsink thermal resistance, Rth c-s2 < 0.10 °C/W Maximum allowable heatsink temperature 100 °C Maximum allowable junction temperature 125 °CSpecifications are subject to change without notice (31.01.2023)

RM1A, RM1BHeatsink Dimensions

(load current versus ambient temperature) (cont.)RM..100Load

current [A]Thermal resistance

[°C/W]100.090.080.070.060.050.040.030.020.010.00.540.680.861.081.371.702.213.064.789.98200.450.580.740.941.201.491.932.684.188.73300.360.470.620.801.031.281.662.303.597.49400.270.370.500.660.851.061.381.912.996.24500.180.270.380.520.680.851.101.532.394.99600.090.170.260.380.510.640.831.151.793.7470TAAmbient temp. [°C] Junction to ambient thermal resistance, Rth j-a < 20.0

Junction to case thermal resistance, Rth j-c < 0.30

Case to heatsink thermal resistance, Rth c-s2 < 0.10

Maximum allowable heatsink temperature 100

Maximum allowable junction temperature 125

°C/W°C/W°C/W°C°C2. Thermal resistance case to heatsink valves are applicable upon application of a fine layer of silicon based thermal paste HTS02S from Electrolube between

SSR and l Specifications 50 RM1.60.100-20° to 70°C

-40° to 100°C

≤ 125°C

≤ 0.80°C/W

≤ 20.0°C/W

-20° to 70°C

-40° to 100°C

≤ 125°C

≤ 0.50°C/W

≤ 20.0°C/W

-20° to 70°C

-40° to 100°C

≤ 125°C

≤ 0.72°C/W

≤ 20.0°C/W

-20° to 70°C

-40° to 100°C

≤ 125°C

≤ 0.35°C/W

≤ 20.0°C/W

-20° to 70°C-40° to 100°C≤ 125°C≤ 0.30°C/W≤ 20.0°C/WOperating temperature range

Storage temperature range

Junction temperature

Rth junction to case

Rth junction to ambient

Heatsink SelectionOrdering Key• Heatsinks and fans• 5.40oC/W to 0.12oC/W thermal resistance• DIN, panel or thru wall mounting• Single or multiple SSR mountingRHS..Heatsink Range Overview:/images/PIM/DATASHEET/ENG/SSR_tsink Selector Tool:/nsc/hq/en/solid_state_relaysSpecifications are subject to change without notice (31.01.2023)

7

RM1A, RM1BShort Circuit ProtectionProtection Co-ordination, Type 1 vs. Type 2:Type 1 protection implies that after a short circuit, the device under test will no longer be in a functioning state. In type

2 co-ordination the device under test will still be functional after the short circuit. In both cases, however, the short circuit

has to be interrupted. The fuse between enclosure and supply shall not open. The door or cover of the enclosure shall not

be blown open. There shall be no damage to conductors of terminals and the conductors shall not separate from terminals.

Therese shall be no breakage or cracking of insulating bases to the extent that the integrity of the mounting of live parts is

impaired. Discharge of parts or any risk of fire shall not occur.

The product variants listed in the table hereunder are suitable for use on a circuit capable of delivering not more than

65,000A rms Symmetrical Amperes, 600Volts maximum when protected by fuses. Tests at 65,000A were performed with

Class J, fast acting: please refer to the table below for maximum allowed ampere rating of the fuse. Use fuses only.

Co-ordination type 1 (UL508)Part No.

RM1..25..

RM1..50..

RM1..75..

RM1..100..

Prospective short

circuit current [kArms]65

65

65

65

Max. fuse size [A] Class/ Model Voltage [VAC]

30

30

20

80

60

80

60

J or CC

J

HSJ20 (Mersen*)

J

HSJ60 (Mersen*)

J

HSJ60 (Mersen*)

600600

600600

600600

600Co-ordination type 2 (IEC/EN60947-4-3)Part No.

.25.. (xx = 23, 40 or 48)

RM1.60.25..

.50.. (xx = 23 or 40)

.50.. (xx = 48 or 60)

.75.. (xx = 23, 40, 48 or 60)

.100.. (xx = 23, 40, 48 or 60)

zz = 00, without fuse trip indication

zz = 21, with fuse trip indication

* Formerly Ferraz ShawmutProspective short

circuit current [kArms]

10

10

10

10

10

10

Max. fuse Brand

size [A]

25

20

50

50

63

100

Mersen*

Mersen*

Mersen*

Mersen*

Mersen*

Mersen*

Model Size

6.9 gRB 10-25

6.9 gRB 10-20

6.9zz CP gRC 14x51/50

6.9zz CP gRC 22x58/50

6.9zz CP gRC 22x58/63

6.9zz CP gRC 22x58/100

10.3 x 3810.3 x 3814 x 5122 x 5822 x 5822 x 58

8

Specifications are subject to change without notice (31.01.2023)

RM1A, RM1BType 2 Protection with Miniature Circuit Breakers (M.C.B.s)Solid State Relay

type

ABB Model no. for

Z - type M. C. B.

(rated current)

ABB Model no. for

B - type M. C. B.

(rated current)

Wire cross

sectional area [mm2]

Minimum length of

Cu wire conductor [m]*

21.0

21.0

31.5

7.6

11.4

19.0

5.2

7.8

13.0

20.8

12.6

21.0

25.0

40.0

19.0

30.4

4.2

7.0

11.2

13.0

20.8

31.2

1.8

3.0

4.8

5.0

8.0

12.0

20.0

14.8

22.2

37.0

4.8

7.2

12.0

19.2

7.2

12.0

19.2

RM1..25.. 1-pole

S201-Z4 (4A)

S201-Z6 UC (6A)

RM1..50.. 1-pole

S201-Z10 (10A)

S201-Z16 (16A)

S201-Z20 (20A)

S201-Z25 (25A)

2-pole

S202-Z25 (25A)

RM1..75.. 1-pole

S201-Z20 (20A)

S201-Z32 (32A)

2-pole

S202-Z20 (20A)

S202-Z32 (32A)

S202-Z50 (50A)

RM1..100.. 1-pole

S201-Z50 (50A)

S201-Z63 (63A)

S201-B2 (2A) 1.0

S201-B2 (2A) 1.0

1.5

S201-B4 (4A) 1.0

1.5

2.5

S201-B6 (6A) 1.0

1.5

2.5

4.0

S201-B10 (10A) 1.5

2.5

S201-B13 (13A) 2.5

4.0

S202-B13 (13A) 2.5

4.0

S201-B10 (10A) 1.5

2.5

4.0

S201-B16 (16A) 2.5

4.0

6.0

S202-B10 (10A) 1.5

2.5

4.0

S202-B16 (16A) 2.5

4.0

6.0

10.0

S202-B25 (25A) 4.0

6.0

10.0

S201-B25 (25A) 4.0

6.0

10.0

16.0

S201-B32 (32A) 6.0

10.0

16.0

* Between MCB and Load (including return path which goes back to the mains).Note: A prospective current of 6kA and a 230/400V power supply system is assumed for the above suggested specifications. For cables with different cross

section than those mentioned above please consult Carlo Gavazzi’s Technical Support ications are subject to change without notice (31.01.2023)

9

RM1A, RM1BEnvironmental InformationThe declaration in this section is prepared in compliance with People’s Republic of China Electronic Industry Standard SJ/T11364-2014: Marking for the Restricted Use of Hazardous Substances in Electronic and Electrical NameLead(Pb)Power Unit AssemblyxMercury(Hg)OToxic or Harardous Substances and ElementsCadmium(Cd)OHexavalent

Chromium

(Cr(Vl))OPolybrominated

biphenyls (PBB)OPolybrominated

diphenyl ethers

(PBDE)OO: Indicates that said hazardous substance contained in homogeneous materials fot this part are below the limit require-ment of GB/T 26572.X: Indicates that said hazardous substance contained in one of the homogeneous materials used for this part is above the

limit requirement of GB/T 26572.环境特性这份申明根据中华人民共和国电子工业标准SJ/T11364-2014:标注在电子电气产品中限定使用的有害物质零件名称铅(Pb)功率单元x汞(Hg)O镉(Cd)O有毒或有害物质与元素六价铬(Cr(Vl))O多溴化联苯(PBB)O多溴联苯醚(PBDE)OO:此零件所有材料中含有的该有害物低于GB/T 26572的限定。X: 此零件某种材料中含有的该有害物高于GB/T 26572的限定。2510

Specifications are subject to change without notice (31.01.2023)

RM1A, RM1BFASTON terminals

• Faston tabs• Tab dimensions according

to DIN 46342 part 1• Pure tin-plated brassOrdering KeyScrew mounted

Faston terminalsRS, RM Solid State RelayFaston terminalsTab orientationInput Tab width: 4.8mmOutput Tab width: 6.3mmRM1A48D25 F 4*Faston terminals

in packs of 20RS, RM Solid State RelayTab orientation** RM48 F4**0: Flat (0º)4: Angled (45º)** 48: 4.8mm faston for input 63: 6.3mm faston for outputFork Terminals

• Terminal adaptors for 35mm2 cable• Type RM635FK• Pack size: 10 piecesOrdering KeyRM terminal adaptorTouch protected (optional) RM635FK POther Accessories• Graphite thermal pad

with adhesive on one

side• Type KK071CUT• Dimensions: 35 x 43 x

0.25mm• Packing quantity: 50pcs.• Touch safety cover• Type RMIP20• IP20 protection degree• Pack size: 20 piecesAll accessories can be ordered pre-assembled with Solid State accessories include DIN rail adaptors, fuses, varistors and futher information refer to Accessories datasheets at:/images/PIM/DATASHEET/ENG/SSR_cifications are subject to change without notice (31.01.2023)

11

发布评论

评论列表 (0)

  1. 暂无评论