基于Proteus的PX2001型野战洗手器的功能改进与仿真

张伟;李效银;尹晓峰;张谷敏;王静雅

【摘 要】Objective: To improve and upgrade the PX2001 type hand-

washing device of field, and ensure its safety and reliability in works.

Methods: Using HMS87C1202AP single-chip microcomputer to control the

hand-washing device. And monitoring device of liquid level and

acoustooptic alarm circuit were added to real-time device so as to monitor

the liquid level and raise the alarm when liquid level was too low. Results:

The circuit can accurately monitor the liquid level. And the circuit can be

cut off automatically when the liquid level was too low, and it can forcibly

protect pump device. Conclusion: The improved hand-washing device has

the following advantages, included of low cost, easy-operating, safety and

reliability, high stability etc., which contribute to raise the utilization rate

and play a more effectively role for decontamination in both wartime and

peacetime.%目的:对PX2001型野战洗手器进行改进升级,以确保其工作安全可靠.

方法:使用HMS87C1202AP单片机控制,增设液位监测装置,设计声、光报警电路

来实时对液位进行监测报警.结果:该电路能准确监测液面是否满足工作条件,且当液

位过少时可自动切断电路,强制保护水泵器件,确保装备在正常条件下工作.结论:基于

Proteus的PX2001型野战洗手器的功能改进方式具有经费使用低、操作便利、

安全可靠、稳定性高等特点,极大提高了其使用率,能够在战时或非战时有效的发挥

消洗作用.

【期刊名称】《中国医学装备》

【年(卷),期】2018(015)004

【总页数】3页(P31-33)

【关键词】洗手器;HMS87C1202AP;Proteus;改进;电路仿真

【作 者】张伟;李效银;尹晓峰;张谷敏;王静雅

【作者单位】济南军区联勤部药品仪器检验所 山东 济南 250022;解放军第89医

院放射科 山东 潍坊 261021;济南军区联勤部药品仪器检验所 山东 济南 250022;

济南军区联勤部药品仪器检验所 山东 济南 250022;济南军区联勤部药品仪器检验

所 山东 济南 250022

【正文语种】中 文

【中图分类】R197.39

PX2001型野战洗手器(上海品兴公司)是一款适用于野战环境下,便于清洗消毒的

洗手装置,其主要应用于现役部队卫生院(所),便于医护人员在开展医疗工作前的

消毒清洗工作。野战洗手器以水泵作为动力系统[1]进行消洗作业,具有便携、安

全、使用方便、无交叉感染等特点,使用范围广泛;应用频率之高,故其故障率高

发,尤其是水泵故障尤为突出。为此,本研究对野战洗手器进行功能改进升级,确

保其使用安全可靠。

1 野战洗手器功能改进

1.1 野战洗手器常见故障

通过对部队此类装备的检修数据分析,PX2001型野战洗手器因水泵动力系统失灵

[2]而引起的装备故障率在96%以上,为避免此类故障的高发,本研究对其结构认

真分析总结,发现水泵在净水桶缺水的状态下仍旧高速运转,从而降低水泵寿命,

导致故障频出。

1.2 故障分析

为避免此类故障的发生,应防止水泵因缺水而长时间空转,如果利用人为因素来时

常注意净水桶水位,不够精确,浪费人力和时间,且做不到实时观察,无法较好的

避免。为此,应增加一部分净水桶内水位监测模块,利用单片机实时监测控制净水

桶内的水位变化,在其缺水的状态下,能及时有效的切断水泵工作电压,有效避免

其空转干烧而造成的损坏后果。既解放了人力,又节约时间,做到精准到位,全程

无任何交叉感染,有效避免人体接触。

1.3 原有电路分析

PX2001型野战洗手器的电路部分由电源整流电路、变压电路、比较电路、延时电

路、CPU及水泵控制电路等部分组成(如图1所示)。

图1 洗手器工作流程图

分析水泵控制电路得出,打开电源,通过变压器分压15 Vac加入电路,通过整流、

滤波。一路通过L7805CV稳压5 Vdc,为单片机,各个芯片部件供电,保证其能

正常工作;另一路通过继电器,WS3(LM317T)调压,提供9~10 Vdc稳压电源,

为水泵供电[3-4]。当有电源时,电源指示灯亮起,同时单片机

IC1(HMS87C1202AP)工作,2脚、10脚输出高电平,注水指示灯亮起,三极管

VT1导通,J1继电器工作,从而使得WS3调压后的电压直接加在水泵上,水泵工

作,开始注水。水泵工作与否,是通过单片机IC1的10脚输出电源高低,从而控

制VT1的通断,进而控制J1工作与否来决定水泵是否工作。

该型号洗手器采用无接触型光感探头控制出水模式,可以有效节约用水,防止触摸

带来的交叉感染[5]。光电传感器有棕、黑、蓝3条线,其中棕色电源线接+5 Vdc、

黑色为信号线(起初为高电平)、蓝色为接地线。当有需要洗手消毒时,靠近洗手器,

光电开关感应到有物体的漫反射光[6]使得IC2芯片的3号引脚(即黑色信号线)由

高电平跳变为低电平,从而1脚输出电压由高电平跳变为低电平传输给IC1的中

断引脚16脚,单片机接受中断,判断有需要洗手消毒,10脚输出高电平,进而

控制J1导通,水泵开始注水,使得水箱因水满而溢出,达到出水目的。当无需要

洗消工作时反之,J1断开,水泵停止注水,以达到节约用水的目的。

针对洗手器的工作流程分析,只有切断水泵电源,才能有效防止水泵因缺水而干烧

造成损坏。然而切断电源有两种途径,①自动切断装置的总电源;②自动切断水泵

的供电电源。分析两种措施得出:如果切断总电源,固然在缺水时能够对水泵起到

很好的保护作用,然而装置的总电源断电会影响到其他部件的正常工作,无法处于

待机状态,即使重新补充水源,洗手器也无法在较短的时间内发挥作用;而第二种

措施是在水泵的供电回路中增加一个继电器,增设水位监测及声、光报警电路,通

过水位开关的通断监测从而通过继电器控制水泵供电回路的通断,实现声、光报警,

这样对装置其他部件不影响,均处于待工作状态[7]。补给水源后,装置能够在较

快的时间内投入使用,为工作人员的后续工作争取了时间。

2 野战洗手器电路措施改进

研究发现,此洗手器的电路分析易于简单,由单纯的单片机IC1和比较器IC2芯

片简单控制实现水泵的工作与否,但缺少实时监测净水桶内水位状况,无法保证净

水桶内缺水使水泵停止工作,进而水泵损坏率颇高发。为此,本研究采用第二种

(自动切断水泵的供电电源)措施,增设了继电器、水位监测报警电路,以便通过单

片机、报警电路等部件,监测净水桶缺水时及时有效的切断水泵电源,并发出声、

光报警提醒净水桶缺水,能够很好的解决水泵因缺水而空转干烧的问题[8]。

改进的洗手器增加的声、光报警电路,输入端+5 Vdc由线路板+5 V提供,输入

端INPUT与线路板WS1的输入端相连,供给继电器J5线圈电压,输入端

PUMF-与线路板PUMF-触点相连,输入端PUMF+与线路板PUMF+相连,输出

端PUMF--OUTPUT和PUMF++OUTPUT分别与水泵的引脚相接。所选择的液

位开关是EP-4310塑料小浮球开关,此类浮球开关主要由磁簧开关和浮子组成,

浮子内有磁性材料,浮子随被测液位上下移动,触动磁簧开关而检出液位位置。相

比较其他液位开关,其具有体积轻巧、工作原理简单、可靠性高、价格便宜等特点,

被应用于工业、农业、家用电器等诸多领域[9]。

洗手器使用时,接通电源,不再像原有电路一样,净水桶内无论有水无水,水泵直

接工作,而是先通过液位开关判定净水桶是否有水,是否满足水泵工作环境,当净

水桶内液面满足条件,浮子浮起,触动磁簧开关导通,继电器J5不工作,从而使

水泵电源形成完整回路,水泵工作并开始注水,此时声、光报警电路不工作并当净

水桶内缺水时,浮子落下,磁簧开关断开,致使三极管VT2导通,J5得电吸合,

进而切断了水泵的工作回路,水泵停止工作,能够避免因缺水而空转,同时,洗手

器的声光报警电路开始工作,红色LED灯亮起,蜂鸣器LS1报警,提醒工作人员

净水桶内缺水,需及时补充水源(如图2所示)。

3 野战洗手器电路仿真

模拟电路仿真选用英国Labcenter electronics公司开发的Proteus工具软件[10]。

此款软件具有模拟电路仿真、数字电路仿真、微处理器及外围电路组成系统仿真、

各种虚拟仪器测试及图表分析功能、PCB布板等众多强大的功能,可以方便完成

本研究试验所需的模拟(数字)电路测试仿真,并且可通过仿真形成产品,这样在电

子电路的设计过程,缩短开发设计周期,可降低开发成本。

图2 洗手器声光报警电路图

针对上述洗手器的改进电路的设计,比喻应用Proteus 8.0软件将改进电路并入原

有电路进行仿真实验。如图2所示,根据原有电路端子的电压测量,输入端+5 V

接入+5 V直流电源,INPUT接入19 V直流电源,PUMF-接入0 V,PUMF+接

入9.5 V直流电源,并接入示波器,提供所需电压以进行仿真[11]。

当液位开关处于闭合状态,表明净水桶水量充足,U2∶A、U2∶B输入端处于低电

平,非门输出端变为高电平,LED灯不发光,与非门U1∶A输出低电平,故D2

处于截止状态,音频振荡器不起振,扬声器LS1不发出报警声,示波器C输入端

检测为0 V(粉色线条)。同时使三极管VT2处于截止状态,继电器J5线圈无法形

成回路电流,J5不工作,示波器B输入端检测为0 V(蓝色线条),从而使水泵工作

回路完整,水泵工作,开始注水,此仿真声、光均不报警,装备无需补水。当液位

开关处于断开状态,表明净水桶缺水,U2∶A、U2∶B输入端处于高电平,非门输

出端变为低电平,使得LED灯导通亮起,与非门U1∶A输出高电平,音频振荡器

起振工作,其输出的音频信号经过Q2放大后,驱动扬声器LS1发出报警声,示

波器C引脚电压有跳变(粉色线条)。同时使三极管VT2处于导通状态,继电器J5

线圈形成回路电流,J5工作,从而断开水泵工作回路,引起示波器B引脚有跳变

电压(蓝色线条),停止注水。声、光报警提示工作人员装备现处于缺水状态,需及

时补水(如图3所示)。

图3 仿真电路示波器波形图

4 野战洗手器应用效果

新型野战洗手器在普通的洗手器基础上增加了水位监测模块和断路保护系统,该模

块在实际应用中效果显著,能够有效的监测净水桶内的水量情况,当洗手器在缺水

状态时,水泵停止工作,设备蜂鸣器报警,提示使用操作人员及时补充水源,有效

解决了设备因缺水而引发的不必要的故障。改进后在部队应用广泛,取得了较好的

效果。

5 结语

针对水泵故障率频发的情况,本研究对传统的野战洗手器的使用和安全作了改进,

在系统中增加了液位监测模块,并进行了完整仿真实验。装置具有了双重的断路保

护电路,避免了由于电路故障或人为处理不及时而造成水泵在缺水状态下经常性、

长时间空转而干烧损坏,提高了水泵的使用寿命,从而保证了此类洗手器能更好的

发挥其作用[12]。此改进方式具有经费使用低、操作便利、安全可靠、稳定性高等

特点,可广泛使用,并保证装备在战时或非战时有效的发挥其作用。

参考文献

[1]朱明明,秦志强.PX2001型野战洗手器工作原理及故障维修[J].医疗装备,2014,

35(8):92-93.

[2]王维明,官丽梅.PX2001野战洗手器常见故障维修[J].医疗装备,2009,

30(10):69.

[3]黄卢记,栾江峰.基于LM317和AT89C51的数字显示可调稳压电源设计[J].微

计算机信息,2012,28(10):150-151.

[4]谢川.用LM317制作0V~3V可调稳压器[N].电子报,2012-6-24.

[5]陶秀梅.基于NE555时基电路的人体红外遥感开关的设计[N].辽宁师专学报,

2013,15(2):92-93.

[6]王红.一种消毒用红外自动洗手机软硬件的设计[J].医疗装备,2007,28(3):

67-69.

[7]胡鑫.便携式野战电动恒温洗手机的研制[D].西安:第四军医大学生物医学工程

系,2008.

[8]彭幼林,周树仁.野战自动洗手器故障的检修[J].中国医学装备,2006,3(5):

36.

[9]安全,范瑞琪.常用水位传感器的比较和选择[J].水利信息化,2014(3):52-54,

60.

[10]唐晓慧,韦萍萍.基于Protues软件在单片机软硬件仿真实验[J].毕节学院学报,

2012,30(8):96-99.

[11]胡湘娟,杨毅.Protues在电子电路测试与仿真中的应用[J].电子世界,

2014(15):34.

[12]郭毅刚,梅柏坤,张小瑶.基于单片机技术的医用电子手部消毒器设计与应用

前景[J].医疗保健器具,2008(5):23-25.

2024年5月12日发(作者:令狐冬易)

基于Proteus的PX2001型野战洗手器的功能改进与仿真

张伟;李效银;尹晓峰;张谷敏;王静雅

【摘 要】Objective: To improve and upgrade the PX2001 type hand-

washing device of field, and ensure its safety and reliability in works.

Methods: Using HMS87C1202AP single-chip microcomputer to control the

hand-washing device. And monitoring device of liquid level and

acoustooptic alarm circuit were added to real-time device so as to monitor

the liquid level and raise the alarm when liquid level was too low. Results:

The circuit can accurately monitor the liquid level. And the circuit can be

cut off automatically when the liquid level was too low, and it can forcibly

protect pump device. Conclusion: The improved hand-washing device has

the following advantages, included of low cost, easy-operating, safety and

reliability, high stability etc., which contribute to raise the utilization rate

and play a more effectively role for decontamination in both wartime and

peacetime.%目的:对PX2001型野战洗手器进行改进升级,以确保其工作安全可靠.

方法:使用HMS87C1202AP单片机控制,增设液位监测装置,设计声、光报警电路

来实时对液位进行监测报警.结果:该电路能准确监测液面是否满足工作条件,且当液

位过少时可自动切断电路,强制保护水泵器件,确保装备在正常条件下工作.结论:基于

Proteus的PX2001型野战洗手器的功能改进方式具有经费使用低、操作便利、

安全可靠、稳定性高等特点,极大提高了其使用率,能够在战时或非战时有效的发挥

消洗作用.

【期刊名称】《中国医学装备》

【年(卷),期】2018(015)004

【总页数】3页(P31-33)

【关键词】洗手器;HMS87C1202AP;Proteus;改进;电路仿真

【作 者】张伟;李效银;尹晓峰;张谷敏;王静雅

【作者单位】济南军区联勤部药品仪器检验所 山东 济南 250022;解放军第89医

院放射科 山东 潍坊 261021;济南军区联勤部药品仪器检验所 山东 济南 250022;

济南军区联勤部药品仪器检验所 山东 济南 250022;济南军区联勤部药品仪器检验

所 山东 济南 250022

【正文语种】中 文

【中图分类】R197.39

PX2001型野战洗手器(上海品兴公司)是一款适用于野战环境下,便于清洗消毒的

洗手装置,其主要应用于现役部队卫生院(所),便于医护人员在开展医疗工作前的

消毒清洗工作。野战洗手器以水泵作为动力系统[1]进行消洗作业,具有便携、安

全、使用方便、无交叉感染等特点,使用范围广泛;应用频率之高,故其故障率高

发,尤其是水泵故障尤为突出。为此,本研究对野战洗手器进行功能改进升级,确

保其使用安全可靠。

1 野战洗手器功能改进

1.1 野战洗手器常见故障

通过对部队此类装备的检修数据分析,PX2001型野战洗手器因水泵动力系统失灵

[2]而引起的装备故障率在96%以上,为避免此类故障的高发,本研究对其结构认

真分析总结,发现水泵在净水桶缺水的状态下仍旧高速运转,从而降低水泵寿命,

导致故障频出。

1.2 故障分析

为避免此类故障的发生,应防止水泵因缺水而长时间空转,如果利用人为因素来时

常注意净水桶水位,不够精确,浪费人力和时间,且做不到实时观察,无法较好的

避免。为此,应增加一部分净水桶内水位监测模块,利用单片机实时监测控制净水

桶内的水位变化,在其缺水的状态下,能及时有效的切断水泵工作电压,有效避免

其空转干烧而造成的损坏后果。既解放了人力,又节约时间,做到精准到位,全程

无任何交叉感染,有效避免人体接触。

1.3 原有电路分析

PX2001型野战洗手器的电路部分由电源整流电路、变压电路、比较电路、延时电

路、CPU及水泵控制电路等部分组成(如图1所示)。

图1 洗手器工作流程图

分析水泵控制电路得出,打开电源,通过变压器分压15 Vac加入电路,通过整流、

滤波。一路通过L7805CV稳压5 Vdc,为单片机,各个芯片部件供电,保证其能

正常工作;另一路通过继电器,WS3(LM317T)调压,提供9~10 Vdc稳压电源,

为水泵供电[3-4]。当有电源时,电源指示灯亮起,同时单片机

IC1(HMS87C1202AP)工作,2脚、10脚输出高电平,注水指示灯亮起,三极管

VT1导通,J1继电器工作,从而使得WS3调压后的电压直接加在水泵上,水泵工

作,开始注水。水泵工作与否,是通过单片机IC1的10脚输出电源高低,从而控

制VT1的通断,进而控制J1工作与否来决定水泵是否工作。

该型号洗手器采用无接触型光感探头控制出水模式,可以有效节约用水,防止触摸

带来的交叉感染[5]。光电传感器有棕、黑、蓝3条线,其中棕色电源线接+5 Vdc、

黑色为信号线(起初为高电平)、蓝色为接地线。当有需要洗手消毒时,靠近洗手器,

光电开关感应到有物体的漫反射光[6]使得IC2芯片的3号引脚(即黑色信号线)由

高电平跳变为低电平,从而1脚输出电压由高电平跳变为低电平传输给IC1的中

断引脚16脚,单片机接受中断,判断有需要洗手消毒,10脚输出高电平,进而

控制J1导通,水泵开始注水,使得水箱因水满而溢出,达到出水目的。当无需要

洗消工作时反之,J1断开,水泵停止注水,以达到节约用水的目的。

针对洗手器的工作流程分析,只有切断水泵电源,才能有效防止水泵因缺水而干烧

造成损坏。然而切断电源有两种途径,①自动切断装置的总电源;②自动切断水泵

的供电电源。分析两种措施得出:如果切断总电源,固然在缺水时能够对水泵起到

很好的保护作用,然而装置的总电源断电会影响到其他部件的正常工作,无法处于

待机状态,即使重新补充水源,洗手器也无法在较短的时间内发挥作用;而第二种

措施是在水泵的供电回路中增加一个继电器,增设水位监测及声、光报警电路,通

过水位开关的通断监测从而通过继电器控制水泵供电回路的通断,实现声、光报警,

这样对装置其他部件不影响,均处于待工作状态[7]。补给水源后,装置能够在较

快的时间内投入使用,为工作人员的后续工作争取了时间。

2 野战洗手器电路措施改进

研究发现,此洗手器的电路分析易于简单,由单纯的单片机IC1和比较器IC2芯

片简单控制实现水泵的工作与否,但缺少实时监测净水桶内水位状况,无法保证净

水桶内缺水使水泵停止工作,进而水泵损坏率颇高发。为此,本研究采用第二种

(自动切断水泵的供电电源)措施,增设了继电器、水位监测报警电路,以便通过单

片机、报警电路等部件,监测净水桶缺水时及时有效的切断水泵电源,并发出声、

光报警提醒净水桶缺水,能够很好的解决水泵因缺水而空转干烧的问题[8]。

改进的洗手器增加的声、光报警电路,输入端+5 Vdc由线路板+5 V提供,输入

端INPUT与线路板WS1的输入端相连,供给继电器J5线圈电压,输入端

PUMF-与线路板PUMF-触点相连,输入端PUMF+与线路板PUMF+相连,输出

端PUMF--OUTPUT和PUMF++OUTPUT分别与水泵的引脚相接。所选择的液

位开关是EP-4310塑料小浮球开关,此类浮球开关主要由磁簧开关和浮子组成,

浮子内有磁性材料,浮子随被测液位上下移动,触动磁簧开关而检出液位位置。相

比较其他液位开关,其具有体积轻巧、工作原理简单、可靠性高、价格便宜等特点,

被应用于工业、农业、家用电器等诸多领域[9]。

洗手器使用时,接通电源,不再像原有电路一样,净水桶内无论有水无水,水泵直

接工作,而是先通过液位开关判定净水桶是否有水,是否满足水泵工作环境,当净

水桶内液面满足条件,浮子浮起,触动磁簧开关导通,继电器J5不工作,从而使

水泵电源形成完整回路,水泵工作并开始注水,此时声、光报警电路不工作并当净

水桶内缺水时,浮子落下,磁簧开关断开,致使三极管VT2导通,J5得电吸合,

进而切断了水泵的工作回路,水泵停止工作,能够避免因缺水而空转,同时,洗手

器的声光报警电路开始工作,红色LED灯亮起,蜂鸣器LS1报警,提醒工作人员

净水桶内缺水,需及时补充水源(如图2所示)。

3 野战洗手器电路仿真

模拟电路仿真选用英国Labcenter electronics公司开发的Proteus工具软件[10]。

此款软件具有模拟电路仿真、数字电路仿真、微处理器及外围电路组成系统仿真、

各种虚拟仪器测试及图表分析功能、PCB布板等众多强大的功能,可以方便完成

本研究试验所需的模拟(数字)电路测试仿真,并且可通过仿真形成产品,这样在电

子电路的设计过程,缩短开发设计周期,可降低开发成本。

图2 洗手器声光报警电路图

针对上述洗手器的改进电路的设计,比喻应用Proteus 8.0软件将改进电路并入原

有电路进行仿真实验。如图2所示,根据原有电路端子的电压测量,输入端+5 V

接入+5 V直流电源,INPUT接入19 V直流电源,PUMF-接入0 V,PUMF+接

入9.5 V直流电源,并接入示波器,提供所需电压以进行仿真[11]。

当液位开关处于闭合状态,表明净水桶水量充足,U2∶A、U2∶B输入端处于低电

平,非门输出端变为高电平,LED灯不发光,与非门U1∶A输出低电平,故D2

处于截止状态,音频振荡器不起振,扬声器LS1不发出报警声,示波器C输入端

检测为0 V(粉色线条)。同时使三极管VT2处于截止状态,继电器J5线圈无法形

成回路电流,J5不工作,示波器B输入端检测为0 V(蓝色线条),从而使水泵工作

回路完整,水泵工作,开始注水,此仿真声、光均不报警,装备无需补水。当液位

开关处于断开状态,表明净水桶缺水,U2∶A、U2∶B输入端处于高电平,非门输

出端变为低电平,使得LED灯导通亮起,与非门U1∶A输出高电平,音频振荡器

起振工作,其输出的音频信号经过Q2放大后,驱动扬声器LS1发出报警声,示

波器C引脚电压有跳变(粉色线条)。同时使三极管VT2处于导通状态,继电器J5

线圈形成回路电流,J5工作,从而断开水泵工作回路,引起示波器B引脚有跳变

电压(蓝色线条),停止注水。声、光报警提示工作人员装备现处于缺水状态,需及

时补水(如图3所示)。

图3 仿真电路示波器波形图

4 野战洗手器应用效果

新型野战洗手器在普通的洗手器基础上增加了水位监测模块和断路保护系统,该模

块在实际应用中效果显著,能够有效的监测净水桶内的水量情况,当洗手器在缺水

状态时,水泵停止工作,设备蜂鸣器报警,提示使用操作人员及时补充水源,有效

解决了设备因缺水而引发的不必要的故障。改进后在部队应用广泛,取得了较好的

效果。

5 结语

针对水泵故障率频发的情况,本研究对传统的野战洗手器的使用和安全作了改进,

在系统中增加了液位监测模块,并进行了完整仿真实验。装置具有了双重的断路保

护电路,避免了由于电路故障或人为处理不及时而造成水泵在缺水状态下经常性、

长时间空转而干烧损坏,提高了水泵的使用寿命,从而保证了此类洗手器能更好的

发挥其作用[12]。此改进方式具有经费使用低、操作便利、安全可靠、稳定性高等

特点,可广泛使用,并保证装备在战时或非战时有效的发挥其作用。

参考文献

[1]朱明明,秦志强.PX2001型野战洗手器工作原理及故障维修[J].医疗装备,2014,

35(8):92-93.

[2]王维明,官丽梅.PX2001野战洗手器常见故障维修[J].医疗装备,2009,

30(10):69.

[3]黄卢记,栾江峰.基于LM317和AT89C51的数字显示可调稳压电源设计[J].微

计算机信息,2012,28(10):150-151.

[4]谢川.用LM317制作0V~3V可调稳压器[N].电子报,2012-6-24.

[5]陶秀梅.基于NE555时基电路的人体红外遥感开关的设计[N].辽宁师专学报,

2013,15(2):92-93.

[6]王红.一种消毒用红外自动洗手机软硬件的设计[J].医疗装备,2007,28(3):

67-69.

[7]胡鑫.便携式野战电动恒温洗手机的研制[D].西安:第四军医大学生物医学工程

系,2008.

[8]彭幼林,周树仁.野战自动洗手器故障的检修[J].中国医学装备,2006,3(5):

36.

[9]安全,范瑞琪.常用水位传感器的比较和选择[J].水利信息化,2014(3):52-54,

60.

[10]唐晓慧,韦萍萍.基于Protues软件在单片机软硬件仿真实验[J].毕节学院学报,

2012,30(8):96-99.

[11]胡湘娟,杨毅.Protues在电子电路测试与仿真中的应用[J].电子世界,

2014(15):34.

[12]郭毅刚,梅柏坤,张小瑶.基于单片机技术的医用电子手部消毒器设计与应用

前景[J].医疗保健器具,2008(5):23-25.

发布评论

评论列表 (0)

  1. 暂无评论