你的位置:
首页
>
IT圈
>
5dx 5000 specification
2024年6月3日发(作者:漆雕夏柳)
Agilent 5DXSeries 5000
System Specifications
Key Specifications
System Application
The Agilent 5DX Series 5000 is designed for in-line or off-
line automated process testing of solder connections on
PCB assemblies, with pass-thru or pass-back loading. The
system can be used for all standard joint-types and fully
supports inspection of single and double-sided boards hav-
ing dimensions up to 457 x 609 mm (18 x 24 in.).
less than 4% for all component types except capacitors and
through-hole. Note: the minimum repeatability standard
deviation is 0.0025 mm (0.0001 in.).
Test Approach
Digital cross-sectional X-ray images of solder joints are
automatically generated and analyzed. The analysis results
includes a complete quantitative description of each joint,
as well as a list of all defective solder connections found.
Special confirmation and adjustment routines provide sol-
der thickness of key solder joint parameters.
Performance Specifications
Test Speed (joint/sec)
The exact speed depends on the density of the component
layout on the circuit board. Generally speaking, the more
dense the circuit board, the higher the test speed. The typi-
cal range in test speeds is from 80 to 140 joints/second
(including inspection, alignment, surface map, and board
handling time).
Solder Thickness Measurement Repeatability
Solder thickness from 0.05 to 0.25 mm (0.002 to 0.010 in.)
can be measured with a repeatability standard deviation of
Image Acquisition Time (including movement)
Up to 5 images per second.
Load/Unload Time
General Specifications:
Model 5300A
Description
Field of View
Joint Pitch
Top Clearance
Bottom Clearance
Very Fine Pitch
From 5. to
(0.2 to 0.85 in.)
0.3 mm
†
& up
(0.012 in.
†
& up)
9.4 to *
(0.37to1.0 in.*)
30 mm*
(1.2 in.*)
12 seconds per panel for pass-through mode, 15 seconds for
pass-back mode, 6 seconds per panel using dual loading.
Model 5400A
Ultra Fine Pitch
From 5. to
(0.2 to 0.85 in.)
0.2mm
†
& up
(0.008 in.
†
& up)
9.4 to *
(0.37to1.0 in.*)
30 mm*
(1.2 in.*)
Agilent 5DX Series 5000 Model Specifications
Alignment Time
3 to 8 seconds (depending on board size).
Surface Map Time (Points/Second)
Up to 5 points/sec (typical map density is 1 point /
645–2580 sq. mm (1–4 sq. in.).
Board Specifications / Tolerances
Board Handling Size (width x length)
Max.:
Min.:
Aspect Ratio:
457 x 609 mm* (18.0 x 24.0 in.*)
102 x 127 mm† (4.0 x 5.0 in.†)
Board length > = 0.5 x board width*
*Measured from the bottom of the circuit board including a maximum warpage of
1.5mm (0.060 in.). If components at the maximum top clearance are used, slices
cannot extend more than 0.5mm (0.020 in.) below the bottom surface of the
board.
†Assuming pad width is 50% of pitch.
Data is subject to change without notice.
*Boards are handled on the width edges.
†Smaller boards are possible with the use of board carriers.
Maximum Test Area
Board thickness
Max.:
Min.:
A
A
A
System Confirmation & Adjustment
The system automatically adjusts for the following:
•X-ray beam and rotary detector synchronization
•X and Y homing position
•Z homing position
•Gray-scale to solder thickness
•Plane of focus
Review Defects
Review Defects provides the operators a review of a test-
ed board.
445 x 597 mm (17.5 x 23.5 in.)
3.2 mm (0.125 in.)
0.5 mm (0.020 in.)
Maximum and minimum board thickness limits can be exceeded with the use of
board carriers.
Board Width Tolerance
± 0.7 mm (0.0275 in.)
Board Edge Clearance
3 mm (0.118 in.) on parallel edges of the board
(top and bottom side clearance requirement)
Test Development Software
Microsoft Windows®-based software (TestLink) is provid-
ed to input and translate the board layout data into
machine-readable format. CAMCAD Professional soft-
ware is available to translate CAD data to Agilent’s for-
t Supported Application Programming
(ASAP) provides standardized best-practice procedures
for test development. Package Library providescentral
management of all test parameters across all board types.
Test development Workstation allows the majority of test
development to be completed off of Agilent 5DX system.
Board Warpage (after reflow and wave soldering)
Normal board usage requires a warpage of less than 1%*
of any linear dimension (0.01 in./in. or 0.01 mm/mm),
assuming that the overall board dimensions still fit within
the board clearance and width specifications. Maximum
board warpage cannot exceed 2 mm† (0.08 in.†).
Board warpage of 0.5% or less is required to
maximize throughput for some device types.
*Boards with larger warpage percentages can be inspected, but
will require additional surface map points and analysis views.
Board must still fit general boardclearance specifications.
†1.5 mm (0.06 in.) for the Model 5300A/5400A.
Test Development Time (typical)
•Less than 30 minutes to translate and verify CAD data
(using CAMCAD Professional).
•4 hours to 3 days to set up board (including setting
thresholds, laser points, and camera).
Note: board programming time depends greatly on the
board complexity and programmer experience.
Maximum Acceptable Board Weight
(including board carrier)
4.5 Kg (10 lb.)
1 Kg (2.2 lb.) per panel with dual load option
Minimum Acceptable Board Weight
0.03 Kg (.066 lb.)
Board Alignment
The system aligns on solder joints on the boards under
test.
Maximum Acceptable Board Temperatures
(at time of load)
40°C (104°F)
Software Features
Menu Driven Interface
Operator-mode
Used in normal Automatic Test mode. Operator can input
subpanel identification using bar-code or keyboard Or
the 5DXcan run automatically, without operator inter-
vention. Serial number can be used to automatically
select the proper panel program. Bar-codes can be auto-
matically scanned with an in-line bar-code reader (not
included).
Supervisor-mode
Allows complete control of the system which includes
algorithm setup and debug, CAD data generation, and sys-
tem diagnostics.
Data is subject to change without notice.
2
2024年6月3日发(作者:漆雕夏柳)
Agilent 5DXSeries 5000
System Specifications
Key Specifications
System Application
The Agilent 5DX Series 5000 is designed for in-line or off-
line automated process testing of solder connections on
PCB assemblies, with pass-thru or pass-back loading. The
system can be used for all standard joint-types and fully
supports inspection of single and double-sided boards hav-
ing dimensions up to 457 x 609 mm (18 x 24 in.).
less than 4% for all component types except capacitors and
through-hole. Note: the minimum repeatability standard
deviation is 0.0025 mm (0.0001 in.).
Test Approach
Digital cross-sectional X-ray images of solder joints are
automatically generated and analyzed. The analysis results
includes a complete quantitative description of each joint,
as well as a list of all defective solder connections found.
Special confirmation and adjustment routines provide sol-
der thickness of key solder joint parameters.
Performance Specifications
Test Speed (joint/sec)
The exact speed depends on the density of the component
layout on the circuit board. Generally speaking, the more
dense the circuit board, the higher the test speed. The typi-
cal range in test speeds is from 80 to 140 joints/second
(including inspection, alignment, surface map, and board
handling time).
Solder Thickness Measurement Repeatability
Solder thickness from 0.05 to 0.25 mm (0.002 to 0.010 in.)
can be measured with a repeatability standard deviation of
Image Acquisition Time (including movement)
Up to 5 images per second.
Load/Unload Time
General Specifications:
Model 5300A
Description
Field of View
Joint Pitch
Top Clearance
Bottom Clearance
Very Fine Pitch
From 5. to
(0.2 to 0.85 in.)
0.3 mm
†
& up
(0.012 in.
†
& up)
9.4 to *
(0.37to1.0 in.*)
30 mm*
(1.2 in.*)
12 seconds per panel for pass-through mode, 15 seconds for
pass-back mode, 6 seconds per panel using dual loading.
Model 5400A
Ultra Fine Pitch
From 5. to
(0.2 to 0.85 in.)
0.2mm
†
& up
(0.008 in.
†
& up)
9.4 to *
(0.37to1.0 in.*)
30 mm*
(1.2 in.*)
Agilent 5DX Series 5000 Model Specifications
Alignment Time
3 to 8 seconds (depending on board size).
Surface Map Time (Points/Second)
Up to 5 points/sec (typical map density is 1 point /
645–2580 sq. mm (1–4 sq. in.).
Board Specifications / Tolerances
Board Handling Size (width x length)
Max.:
Min.:
Aspect Ratio:
457 x 609 mm* (18.0 x 24.0 in.*)
102 x 127 mm† (4.0 x 5.0 in.†)
Board length > = 0.5 x board width*
*Measured from the bottom of the circuit board including a maximum warpage of
1.5mm (0.060 in.). If components at the maximum top clearance are used, slices
cannot extend more than 0.5mm (0.020 in.) below the bottom surface of the
board.
†Assuming pad width is 50% of pitch.
Data is subject to change without notice.
*Boards are handled on the width edges.
†Smaller boards are possible with the use of board carriers.
Maximum Test Area
Board thickness
Max.:
Min.:
A
A
A
System Confirmation & Adjustment
The system automatically adjusts for the following:
•X-ray beam and rotary detector synchronization
•X and Y homing position
•Z homing position
•Gray-scale to solder thickness
•Plane of focus
Review Defects
Review Defects provides the operators a review of a test-
ed board.
445 x 597 mm (17.5 x 23.5 in.)
3.2 mm (0.125 in.)
0.5 mm (0.020 in.)
Maximum and minimum board thickness limits can be exceeded with the use of
board carriers.
Board Width Tolerance
± 0.7 mm (0.0275 in.)
Board Edge Clearance
3 mm (0.118 in.) on parallel edges of the board
(top and bottom side clearance requirement)
Test Development Software
Microsoft Windows®-based software (TestLink) is provid-
ed to input and translate the board layout data into
machine-readable format. CAMCAD Professional soft-
ware is available to translate CAD data to Agilent’s for-
t Supported Application Programming
(ASAP) provides standardized best-practice procedures
for test development. Package Library providescentral
management of all test parameters across all board types.
Test development Workstation allows the majority of test
development to be completed off of Agilent 5DX system.
Board Warpage (after reflow and wave soldering)
Normal board usage requires a warpage of less than 1%*
of any linear dimension (0.01 in./in. or 0.01 mm/mm),
assuming that the overall board dimensions still fit within
the board clearance and width specifications. Maximum
board warpage cannot exceed 2 mm† (0.08 in.†).
Board warpage of 0.5% or less is required to
maximize throughput for some device types.
*Boards with larger warpage percentages can be inspected, but
will require additional surface map points and analysis views.
Board must still fit general boardclearance specifications.
†1.5 mm (0.06 in.) for the Model 5300A/5400A.
Test Development Time (typical)
•Less than 30 minutes to translate and verify CAD data
(using CAMCAD Professional).
•4 hours to 3 days to set up board (including setting
thresholds, laser points, and camera).
Note: board programming time depends greatly on the
board complexity and programmer experience.
Maximum Acceptable Board Weight
(including board carrier)
4.5 Kg (10 lb.)
1 Kg (2.2 lb.) per panel with dual load option
Minimum Acceptable Board Weight
0.03 Kg (.066 lb.)
Board Alignment
The system aligns on solder joints on the boards under
test.
Maximum Acceptable Board Temperatures
(at time of load)
40°C (104°F)
Software Features
Menu Driven Interface
Operator-mode
Used in normal Automatic Test mode. Operator can input
subpanel identification using bar-code or keyboard Or
the 5DXcan run automatically, without operator inter-
vention. Serial number can be used to automatically
select the proper panel program. Bar-codes can be auto-
matically scanned with an in-line bar-code reader (not
included).
Supervisor-mode
Allows complete control of the system which includes
algorithm setup and debug, CAD data generation, and sys-
tem diagnostics.
Data is subject to change without notice.