最新消息: USBMI致力于为网友们分享Windows、安卓、IOS等主流手机系统相关的资讯以及评测、同时提供相关教程、应用、软件下载等服务。

Pepperl+Fuchs UB4000-F42-E5-V15产品说明书

IT圈 admin 32浏览 0评论

2024年8月1日发(作者:军水悦)

Ultrasonic sensorUB4000-F42-E5-V15

Technical data

General specifications

Sensing range

Adjustment range

Dead band

Standard target plate

Transducer frequency

Response delay

Indicators/operating means

LED green

LED yellow

LED red

Electrical specifications

Operating voltage U

B

No-load supply current I

0

Input/Output

Synchronization

200 ... 4000 mm

240 ... 4000 mm

0 ... 200 mm

100 mm x 100 mm

approx. 85 kHz

approx. 325 ms

solid green: Power on

solid: switching state switch output

flashing: program function

normal operation: "fault"

program function: no object detected

10 ... 30 V DC , ripple10%

SS

≤ 60 mA

bi-directional

0 level -U

B

...+1 V

1 level: ++U

B

input impedance: > 12 KOhm

synchronization pulse: ≥ 100 µs, synchronization interpulse

period: ≥ 2 ms

≤ 13 Hz

≤ 13/n Hz, n = number of sensors

1 switching output E5, PNP NO/NC, programmable

200 mA , short-circuit/overload protected

Switch point A1: 240 mm , Switch point A2: 4000 mm , wide

sound lobe

≤ 2.5 V

≤ 0.5 % of switching point

≤ 1.2 Hz

1 % of the set operating distance

± 1 % of full-scale value

Model Number

UB4000-F42-E5-V15

Single head system

Synchronization frequency

Common mode operation

Multiplex operation

Output

Output type

Rated operating current I

e

Default setting

Features

•Switch output

•Extremely small unusable area

•TEACH-IN

•Interference suppression (adjus-

table divergence of sound cone in

close range)

•Temperature compensation

•Synchronization options

•NO/NC selectable

Diagrams

Characteristic response curve

Distance Y [m]

2

1.5

1

0.5

0

-0.5

-1

Flat surface 100 mm x 100 mm

Voltage drop U

d

Repeat accuracy

Switching frequency f

Range hysteresis H

Temperature influence

Ambient conditions

Ambient temperature -25 ... 70 °C (-13 ... 158 °F)

Storage temperature -40 ... 85 °C (-40 ... 185 °F)

Mechanical specifications

Connection type Connector M12 x 1 , 5-pin

Degree of protection IP54

Material

Housing ABS

Transducer epoxy resin/hollow glass sphere mixture; foam

polyurethane, cover PBT

Mass 150 g

Compliance with standards and

directives

Standard conformity

Standards EN 60947-5-2:2007 + A1:2012

IEC 60947-5-2:2007 + A1:2012

Approvals and certificates

UL approval

CSA approval

CCC approval

cULus Listed, General Purpose

cCSAus Listed, General Purpose

1

3

4

0

0

0

_

e

n

g

.

x

m

l

-1.5

-2

Round bar, Ø 25 mm

0 1 2 3 4 5 6

Distance X [m]

CCC approval / marking not required for products rated

≤36 V

Y

X

wide sonic beam

narrow sonic beam

Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.

Pepperl+Fuchs GroupUSA: +1 330 486 0001Germany: +49 621 776 4411

************************.************************.com

R

e

l

e

a

s

e

d

a

t

e

:

2

0

1

6

-

0

2

-

2

6

1

1

:

3

2

D

a

t

e

o

f

i

s

s

u

e

:

2

0

1

6

-

0

2

-

2

6

Singapore: +65 6779 9091

************************.com

1

Ultrasonic sensorUB4000-F42-E5-V15

Dimensions

Additional Information

Programmable operation modes

157.5

5.2

Unusable area

1

5

.

5

Membrane keys

M

1

2

x

1

A

2

30

5

2

.

5

Object distance

T

E

A

C

H

I

N

S

E

T

1. Switching point mode

N. C.

A2

N. O.

A1

Object-

presence

A1, A2

6

5

8

0

M

O

D

E

LED window

5

16

A

1

3

4

A1

A2

10

34

65

80

Detection-

limit

2. Window mode

N. O.

A2 > A1

N. C.

A1> A2

A1A2

A2A1

3. Hysteresis mode

N. C.

A2 > A1

Electrical Connection

Standard symbol/Connections:

(version E5, pnp)

1

(BN)

+ U

B

2

(WH)

Program input

A1

N. O.

A1 > A2

A2

A2

A1

U

Note:

means: cover transducer surface with your hand,

while teaching the switching point.

If A1 = A2, the output works like A2 > A1

5

4

3

(GY)

(BK)

(BU)

Sync. input

Switch output

- U

B

Wire colors in accordance with EN 60947-5-2.

Pinout

1

2

3

5

4

Wire colors in accordance with EN 60947-5-2

1 BN

2 WH

3 UB

4 BK

5 GY

(brown)

(white)

(blue)

(black)

(gray)

2

Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.

Pepperl+Fuchs GroupUSA: +1 330 486 0001Germany: +49 621 776 4411

fa-info@-info@

Singapore: +65 6779 9091

fa-info@

R

e

l

e

a

s

e

d

a

t

e

:

2

0

1

6

-

0

2

-

2

6

1

1

:

3

2

D

a

t

e

o

f

i

s

s

u

e

:

2

0

1

6

-

0

2

-

2

6

1

3

4

0

0

0

_

e

n

g

.

x

m

l

Ultrasonic sensor

Accessories

MH 04-3505

Mounting aid for FP and F42 sensors

MHW 11

Mounting brackets for sensors

V15-G-2M-PVC

Female cordset, M12, 5-pin, PVC cable

Functional Description

UB4000-F42-E5-V15

The sensor may be completely parameterised via two keys on the side panel of the housing. As a special feature provided by

this sensor, the ultrasound beam width may be adapted to the environmental conditions at the place of operation of the sensor.

Specifying the switching points:

When specifying the switching points, the user determines at which points the switching output changes its state. The order of

the switching points A1 > A2, or A1 < A2 also determines the direction of action (i.e. normally-closed/normally-open contact

function).

Specifying the A1 switching point by pressing the A1 key

Holding down the A1key > 2

seconds

Positioning the target object

at the desired distance

Briefly pressing the A1 key

The sensor switches to learn mode and the user may

specify the A1 switching point

The yellow LED of the sensor flashes fast to indicate

that the target object has been recognised. The red

LED flashes if the object has not been recognised.

The sensor terminates the specification of the A1

switching point and saves it as a non-volatile value. The

specified value is invalid if the object is uncertain (i.e.

the red LED lights up at irregular intervals). The learn

mode is exited.

The A2 switching point is specified via the A2 key, analogous to the description above.

Alternatively, the switching points may also be specified electrically via the learn input. To specify the A1 switching point, the

learn input must be connected to

-U

B

; to specify the A2 switching point, it must be connected to +U

B

. Specified values are saved upon the disconnection from

the learn input.

Switching points may only be specified directly after Power on. A time lock secures the adjusted switching points against unin-

tended modification 5 minutes after the last keypress. To modify the switching points later, the user may specify the desired

values only after a new Power On.

Proceed as follows to parameterise the output function and the ultrasound beam width:

Press the A1 key during Power on and hold down the key for another second to ensure that the sensor starts the two-step pa-

rameterisation of the operating modes.

Step 1, parameterisation of the output function

The output function parameterised last is displayed. All output functions available may be selected via consecutive, brief strokes

of the A2 key. These strokes are visualised via short flashes of the green LED.

Operating mode

1 switching point/

object detection

Window function

(default)

Hysteresis mode

Flash sequence of the green LED

pause

A2 key

1

3

4

0

0

0

_

e

n

g

.

x

m

l

pause

R

e

l

e

a

s

e

d

a

t

e

:

2

0

1

6

-

0

2

-

2

6

1

1

:

3

2

D

a

t

e

o

f

i

s

s

u

e

:

2

0

1

6

-

0

2

-

2

6

pause

Hold down the A1 key for 2 seconds to save the selected output mode, complete the parameterisation and ensure that the sen-

sor returns to normal mode. Step 2 may be initiated by briefly pressing the A1 key (parameterisation of the ultrasound beam

width).

Step 2, parameterisation of the ultrasound beam width

In the near range, via Step 2, the ultrasound beam width may be adapted to the requirements of the corresponding application.

The beam width parameterised last is displayed first. Available beam width settings may be selected via consecutive, brief

strokes of the A2 key. These strokes are visualised via the flash sequence of the red LED.

Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.

Pepperl+Fuchs GroupUSA: +1 330 486 0001Germany: +49 621 776 4411

************************.************************.com

Singapore: +65 6779 9091

************************.com

3

Ultrasonic sensor

Beam width

Small beam

UB4000-F42-E5-V15

A2 keyFlash sequence of the red LED

pause

Medium beam

pause

Large beam

pause

Hold down the A1 key for 2 seconds to save the selected beam shape, complete the parameterisation and ensure that the sen-

sor returns to normal mode. Briefly press the A1 key to return to Step 1 (parameterisation of the output function).

If the parameterisation mode is not terminated within 5 minutes after last keypress (by holding down the A1 key for 2 seconds),

the sensor aborts this mode without modifying the settings.

Synchronisation

The sensor has a synchronisation port to suppress mutual influencing. If this port has not been connected, the sensor works at

an internally generated cycle rate. Several sensors may be synchronised via the following options.

External synchronisation:

The sensor may be synchronised via the external application of a square wave voltage. A synchronisation pulse on the syn-

chronisation input initiates a measuring cycle. The pulse width must be greater than 100 µs. The measuring cycle is started with

the falling edge. A low level > 1 s or an open synchronisation input initiate the transition to normal sensor mode. A high level on

the synchronisation input deactivates the sensor.

Two modes are possible:

- Several sensors are controlled via the same synchronisation signal. The sensors work in common mode.

- The synchronisation pulses are forwarded at cyclic intervals to respectively one single sensor. The sensors work in multiplex mode.

Self-synchronisation:

The synchronisation ports of up to 5 sensors suitable for self-synchronisation are connected to each other. These sensors work

in multiplex mode after Power on. The On delay increases depending on the number of sensors to be synchronised. While the

learn mode is active, no synchronisation is possible (and vice-versa). To specify the switching points, the sensors must be op-

erated in non-synchronised mode.

Note:

If the synchronisation option is not used, the synchronisation input must be connected to ground (0V) or the sensor must be

operated with a (4-pole) V1 connecting cable.

Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.

Pepperl+Fuchs GroupUSA: +1 330 486 0001Germany: +49 621 776 4411

************************.************************.com

R

e

l

e

a

s

e

d

a

t

e

:

2

0

1

6

-

0

2

-

2

6

1

1

:

3

2

D

a

t

e

o

f

i

s

s

u

e

:

2

0

1

6

-

0

2

-

2

6

1

3

4

0

0

0

_

e

n

g

.

x

m

l

Singapore: +65 6779 9091

************************.com

4

2024年8月1日发(作者:军水悦)

Ultrasonic sensorUB4000-F42-E5-V15

Technical data

General specifications

Sensing range

Adjustment range

Dead band

Standard target plate

Transducer frequency

Response delay

Indicators/operating means

LED green

LED yellow

LED red

Electrical specifications

Operating voltage U

B

No-load supply current I

0

Input/Output

Synchronization

200 ... 4000 mm

240 ... 4000 mm

0 ... 200 mm

100 mm x 100 mm

approx. 85 kHz

approx. 325 ms

solid green: Power on

solid: switching state switch output

flashing: program function

normal operation: "fault"

program function: no object detected

10 ... 30 V DC , ripple10%

SS

≤ 60 mA

bi-directional

0 level -U

B

...+1 V

1 level: ++U

B

input impedance: > 12 KOhm

synchronization pulse: ≥ 100 µs, synchronization interpulse

period: ≥ 2 ms

≤ 13 Hz

≤ 13/n Hz, n = number of sensors

1 switching output E5, PNP NO/NC, programmable

200 mA , short-circuit/overload protected

Switch point A1: 240 mm , Switch point A2: 4000 mm , wide

sound lobe

≤ 2.5 V

≤ 0.5 % of switching point

≤ 1.2 Hz

1 % of the set operating distance

± 1 % of full-scale value

Model Number

UB4000-F42-E5-V15

Single head system

Synchronization frequency

Common mode operation

Multiplex operation

Output

Output type

Rated operating current I

e

Default setting

Features

•Switch output

•Extremely small unusable area

•TEACH-IN

•Interference suppression (adjus-

table divergence of sound cone in

close range)

•Temperature compensation

•Synchronization options

•NO/NC selectable

Diagrams

Characteristic response curve

Distance Y [m]

2

1.5

1

0.5

0

-0.5

-1

Flat surface 100 mm x 100 mm

Voltage drop U

d

Repeat accuracy

Switching frequency f

Range hysteresis H

Temperature influence

Ambient conditions

Ambient temperature -25 ... 70 °C (-13 ... 158 °F)

Storage temperature -40 ... 85 °C (-40 ... 185 °F)

Mechanical specifications

Connection type Connector M12 x 1 , 5-pin

Degree of protection IP54

Material

Housing ABS

Transducer epoxy resin/hollow glass sphere mixture; foam

polyurethane, cover PBT

Mass 150 g

Compliance with standards and

directives

Standard conformity

Standards EN 60947-5-2:2007 + A1:2012

IEC 60947-5-2:2007 + A1:2012

Approvals and certificates

UL approval

CSA approval

CCC approval

cULus Listed, General Purpose

cCSAus Listed, General Purpose

1

3

4

0

0

0

_

e

n

g

.

x

m

l

-1.5

-2

Round bar, Ø 25 mm

0 1 2 3 4 5 6

Distance X [m]

CCC approval / marking not required for products rated

≤36 V

Y

X

wide sonic beam

narrow sonic beam

Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.

Pepperl+Fuchs GroupUSA: +1 330 486 0001Germany: +49 621 776 4411

************************.************************.com

R

e

l

e

a

s

e

d

a

t

e

:

2

0

1

6

-

0

2

-

2

6

1

1

:

3

2

D

a

t

e

o

f

i

s

s

u

e

:

2

0

1

6

-

0

2

-

2

6

Singapore: +65 6779 9091

************************.com

1

Ultrasonic sensorUB4000-F42-E5-V15

Dimensions

Additional Information

Programmable operation modes

157.5

5.2

Unusable area

1

5

.

5

Membrane keys

M

1

2

x

1

A

2

30

5

2

.

5

Object distance

T

E

A

C

H

I

N

S

E

T

1. Switching point mode

N. C.

A2

N. O.

A1

Object-

presence

A1, A2

6

5

8

0

M

O

D

E

LED window

5

16

A

1

3

4

A1

A2

10

34

65

80

Detection-

limit

2. Window mode

N. O.

A2 > A1

N. C.

A1> A2

A1A2

A2A1

3. Hysteresis mode

N. C.

A2 > A1

Electrical Connection

Standard symbol/Connections:

(version E5, pnp)

1

(BN)

+ U

B

2

(WH)

Program input

A1

N. O.

A1 > A2

A2

A2

A1

U

Note:

means: cover transducer surface with your hand,

while teaching the switching point.

If A1 = A2, the output works like A2 > A1

5

4

3

(GY)

(BK)

(BU)

Sync. input

Switch output

- U

B

Wire colors in accordance with EN 60947-5-2.

Pinout

1

2

3

5

4

Wire colors in accordance with EN 60947-5-2

1 BN

2 WH

3 UB

4 BK

5 GY

(brown)

(white)

(blue)

(black)

(gray)

2

Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.

Pepperl+Fuchs GroupUSA: +1 330 486 0001Germany: +49 621 776 4411

fa-info@-info@

Singapore: +65 6779 9091

fa-info@

R

e

l

e

a

s

e

d

a

t

e

:

2

0

1

6

-

0

2

-

2

6

1

1

:

3

2

D

a

t

e

o

f

i

s

s

u

e

:

2

0

1

6

-

0

2

-

2

6

1

3

4

0

0

0

_

e

n

g

.

x

m

l

Ultrasonic sensor

Accessories

MH 04-3505

Mounting aid for FP and F42 sensors

MHW 11

Mounting brackets for sensors

V15-G-2M-PVC

Female cordset, M12, 5-pin, PVC cable

Functional Description

UB4000-F42-E5-V15

The sensor may be completely parameterised via two keys on the side panel of the housing. As a special feature provided by

this sensor, the ultrasound beam width may be adapted to the environmental conditions at the place of operation of the sensor.

Specifying the switching points:

When specifying the switching points, the user determines at which points the switching output changes its state. The order of

the switching points A1 > A2, or A1 < A2 also determines the direction of action (i.e. normally-closed/normally-open contact

function).

Specifying the A1 switching point by pressing the A1 key

Holding down the A1key > 2

seconds

Positioning the target object

at the desired distance

Briefly pressing the A1 key

The sensor switches to learn mode and the user may

specify the A1 switching point

The yellow LED of the sensor flashes fast to indicate

that the target object has been recognised. The red

LED flashes if the object has not been recognised.

The sensor terminates the specification of the A1

switching point and saves it as a non-volatile value. The

specified value is invalid if the object is uncertain (i.e.

the red LED lights up at irregular intervals). The learn

mode is exited.

The A2 switching point is specified via the A2 key, analogous to the description above.

Alternatively, the switching points may also be specified electrically via the learn input. To specify the A1 switching point, the

learn input must be connected to

-U

B

; to specify the A2 switching point, it must be connected to +U

B

. Specified values are saved upon the disconnection from

the learn input.

Switching points may only be specified directly after Power on. A time lock secures the adjusted switching points against unin-

tended modification 5 minutes after the last keypress. To modify the switching points later, the user may specify the desired

values only after a new Power On.

Proceed as follows to parameterise the output function and the ultrasound beam width:

Press the A1 key during Power on and hold down the key for another second to ensure that the sensor starts the two-step pa-

rameterisation of the operating modes.

Step 1, parameterisation of the output function

The output function parameterised last is displayed. All output functions available may be selected via consecutive, brief strokes

of the A2 key. These strokes are visualised via short flashes of the green LED.

Operating mode

1 switching point/

object detection

Window function

(default)

Hysteresis mode

Flash sequence of the green LED

pause

A2 key

1

3

4

0

0

0

_

e

n

g

.

x

m

l

pause

R

e

l

e

a

s

e

d

a

t

e

:

2

0

1

6

-

0

2

-

2

6

1

1

:

3

2

D

a

t

e

o

f

i

s

s

u

e

:

2

0

1

6

-

0

2

-

2

6

pause

Hold down the A1 key for 2 seconds to save the selected output mode, complete the parameterisation and ensure that the sen-

sor returns to normal mode. Step 2 may be initiated by briefly pressing the A1 key (parameterisation of the ultrasound beam

width).

Step 2, parameterisation of the ultrasound beam width

In the near range, via Step 2, the ultrasound beam width may be adapted to the requirements of the corresponding application.

The beam width parameterised last is displayed first. Available beam width settings may be selected via consecutive, brief

strokes of the A2 key. These strokes are visualised via the flash sequence of the red LED.

Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.

Pepperl+Fuchs GroupUSA: +1 330 486 0001Germany: +49 621 776 4411

************************.************************.com

Singapore: +65 6779 9091

************************.com

3

Ultrasonic sensor

Beam width

Small beam

UB4000-F42-E5-V15

A2 keyFlash sequence of the red LED

pause

Medium beam

pause

Large beam

pause

Hold down the A1 key for 2 seconds to save the selected beam shape, complete the parameterisation and ensure that the sen-

sor returns to normal mode. Briefly press the A1 key to return to Step 1 (parameterisation of the output function).

If the parameterisation mode is not terminated within 5 minutes after last keypress (by holding down the A1 key for 2 seconds),

the sensor aborts this mode without modifying the settings.

Synchronisation

The sensor has a synchronisation port to suppress mutual influencing. If this port has not been connected, the sensor works at

an internally generated cycle rate. Several sensors may be synchronised via the following options.

External synchronisation:

The sensor may be synchronised via the external application of a square wave voltage. A synchronisation pulse on the syn-

chronisation input initiates a measuring cycle. The pulse width must be greater than 100 µs. The measuring cycle is started with

the falling edge. A low level > 1 s or an open synchronisation input initiate the transition to normal sensor mode. A high level on

the synchronisation input deactivates the sensor.

Two modes are possible:

- Several sensors are controlled via the same synchronisation signal. The sensors work in common mode.

- The synchronisation pulses are forwarded at cyclic intervals to respectively one single sensor. The sensors work in multiplex mode.

Self-synchronisation:

The synchronisation ports of up to 5 sensors suitable for self-synchronisation are connected to each other. These sensors work

in multiplex mode after Power on. The On delay increases depending on the number of sensors to be synchronised. While the

learn mode is active, no synchronisation is possible (and vice-versa). To specify the switching points, the sensors must be op-

erated in non-synchronised mode.

Note:

If the synchronisation option is not used, the synchronisation input must be connected to ground (0V) or the sensor must be

operated with a (4-pole) V1 connecting cable.

Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.

Pepperl+Fuchs GroupUSA: +1 330 486 0001Germany: +49 621 776 4411

************************.************************.com

R

e

l

e

a

s

e

d

a

t

e

:

2

0

1

6

-

0

2

-

2

6

1

1

:

3

2

D

a

t

e

o

f

i

s

s

u

e

:

2

0

1

6

-

0

2

-

2

6

1

3

4

0

0

0

_

e

n

g

.

x

m

l

Singapore: +65 6779 9091

************************.com

4

发布评论

评论列表 (0)

  1. 暂无评论