Agilent U2781A

Features

• 6USB module slots

•Simultaneous Synchronization

(SSI)

•Star Trigger

•Internal and external 10 MHz

reference clock

•Trigger in and trigger out signals

•SCPI commands

•IVI-COM driver compatibility

•USB TMC 488.2 Standards

compliant

•USB 2.0 high speed interface

•Rackmount kit available as an

option

6-slot USB Modular Instrument

Chassis

Data Sheet

Introduction

USB modules and the external trigger

Agilent U2781A USB Modular Instrument

signal. The star trigger bus is a dedicated

Chassis is a 4U height chassis with 6 USB

trigger lines between the external trigger

module slots. It is a portable chassis with

input and USB slots. Users can achieve

high performance added value. It targets a

precise trigger between each USB modules

wide range of applications in both industrial

via the synchronization routing of the star

and scientific environments. It helps you

trigger.

lower your cost of test and accelerate your

test system integration and development.

USB backplane

The USB backplane provides a means to

The Agilent U2781A comes with USB plug

synchronize the modules.

and play connectivity. The USB interface

that is compliant with the USBTMC 488.2

Additional Features

Standards works seamlessly with Agilent

A 10MHz system reference clock is

Measurement Manager software and can

supplied to each modules slots. There are

be controlled remotely via industry standard

two temperature sensors and a monitoring

SCPI commands. In addition, the U2781A

fan control circuit to monitor the internal

USB modular instrument chassis comes

temperature and speed of the fans. The fans

with Agilent IO Libraries Suite 14.2. The IO

are mainly used for heat dissipation.

Libraries provide robust instrument control

The chassis also provides external 10MHz

and work with the software development

reference clock, external trigger in and

environment you choose. IVI-COM driver is

trigger out functions via BNC connectors at

also included to ensure an easy integration

the rear panel.

and compatibility with different

programming environments.

Star trigger bus

The U2781A USB modular instrument

chassis comes with star trigger bus, which

offers precise synchronization between

Agilent Technologies

1

ELECTRICAL SPECIFICATIONS

Power Supply AC Input

Input voltage range

Input frequency range

Input current rating

Effiency

Power Supply DC Output

Output rated voltage

Max output rated current

Max output rated power

Over voltage protection

Internal 10 MHz Reference Clock

Accuracy

Slot to slot skew

External 10 MHz Reference Clock

Auto detection level

Input frequency range

Input magnitude

Input impedance

Damage level

External Trigger In

Compatibility

V

IH

(Positive threshold voltage)

V

IL

(Negative threshold voltage)

Hold time

Input voltage range

Slot to slot skew

External Trigger Out

V

OH

V

OL

Output voltage range

100 to 240 VAC

50 to 60 Hz

3.5 A/115 VAC; 1.7 A/230 VAC

75%

12 VDC

16.7 A

200 W

13.2 to 16.2 V

25 ppm for operating range

350 ps

Yes

10 MHz

100 mVpp to 5 Vpp (sine/square wave)

50 Ω ± 5 Ω

10 Vrms

TTL

2.0 V

0.8 V

8 ns pulse width

0 to 5.0 V

350 ps

2.9 V

0.1 V

0 to 3.3 V

MECHANICAL SPECIFICATIONS

Physical Layout

Number of USB module slots

Dimension of each module slot

Dimension of chassis

Weight

Power LED

USB Backplane

Connector

Input signals

Output signal

Cooling Fan

Number of fans

Fan speed

Noise

Power (each fan)

6

25.40 mm (W) x 174.54 mm (D) x 105.00 mm (H)

270.00 mm (W) x 271.20 mm (D) x 197.00 mm (H)

3.7 kg

ON/OFF type

55 pins Ernet male type C

External 10 MHz clock in (BNC connector)

External trigger in (BNC connector)

Trigger out (BNC connector)

2 (at the bottom of the chassis)

3300 rpm ±10%

37 dB(A)

2.52 W

2

GENERAL SPECIFICATIONS

REMOTE INTERFACE

USB 2.0 High Speed

USBTMC Class Device

POWER CONSUMPTION

400 VA maximum

OPERATING ENVIRONMENT

Operating temperature from 0 °C to +55 °C

Relative humidity at 15% to 85% RH (non-condensing)

Altitude up to 4600 meters

STORAGE COMPLIANCE

–20°C to +70°C

SAFETY COMPLIANCE

Certified with:

•IEC 61010-1:2001/EN 61010-1:2001 (2nd Edition)

•USA: UL61010-1: 2004

•Canada: CSA C22.2 No.61010-1:2004

EMC COMPLIANCE

Certified with:

•IEC/EN 61326-1 1998

•CISPR 11: 1990/EN55011:1991 , Group 1, Class A

•CANADA: ICES-001: 1998

•Australia/New Zealand: AS/NZS 2064.1

ACOUSTIC EMISSION

•Sound pressure level: 45.5 dB(A)

•Sound power level: 56.6 dB(A)

SHOCK and VIBRATION

Tested to IEC/EN 60068-2

DIMENSION (WxDxH)

270.00 mm x 271.20 mm x 197.00 mm

WEIGHT

3.7 kg

WARRANTY

One year

SOFTWARE

REQUIREMENT

Agilent connectivity software included

Agilent IO Libraries Suite 14.2

Minimum system requirements (IO libraries and drivers)

PC hardware 500 MHz Pentium III or higher,

256 MB RAM,

40 GB hard disk space, CD-ROM drive

Operating System Windows 2000 or higher

Computer Interface USB 2.0 high speed

Software driver support for programming languages

Software driver : IVI-COM

Compatible with programming environments:

Agilent VEE Pro, Agilent T&M Toolkit

Microsoft Visual , C/C++

Visual Basic 6

LabVIEW

MATLAB

PRODUCT OVERVIEW

FRONT VIEW

197 m

270 mm

REAR VIEW

Standard Shipped Components:

•USB Interface Cable

•Quick Start Guide

•Functional Test Certificate

•Product Reference CD-ROM

•Agilent IO Libraries Suite 14.2 CD-ROM

Optional Accessories:

•U2905A Rackmount Kit for the U2781A 6-slot USB Modular Instrument

Chassis

3

Agilent Technologies’ Test and Measurement Support, Services, and Assistance

Agilent Technologies aims to maximize the value you receive, while minimizing your risk and

problems. We strive to ensure that you get the test and measurement capabilities you paid for

and obtain the support you need. Our extensive support resources and services can help you

choose the right Agilent products for your applications and apply them successfully. Every

instrument and system we sell has a global warranty. Two concepts underlie Agilent’s overall

support policy: “Our Promise” and “Your Advantage.”

Our Promise

Our Promise means your Agilent test and measurement equipment will meet its advertised

performance and functionality. When you are choosing new equipment, we will help you with

product information, including realistic performance specifications and practical

recommendations from experienced test engineers. When you receive your new Agilent

equipment, we can help verify that it works properly and help with initial product operation.

Your Advantage

Your Advantage means that Agilent offers a wide range of additional expert test and

measurement services, which you can purchase according to your unique technical and

business needs. Solve problems efficiently and gain a competitive edge by contracting with us

for calibration, extra-cost upgrades, out-of-warranty repairs, and on-site education and training,

as well as design, system integration, project management, and other professional engineering

services. Experienced Agilent engineers and technicians worldwide can help you maximize your

productivity, optimize the return on investment of your Agilent instruments and systems, and

obtain dependable measurement accuracy for the life of those products.

Agilent Email Updates

/find/emailupdates

Get the latest information on the products and applications you select.

Agilent Direct

/find/agilentdirect

Quickly choose and use your test equipment solutions with confidence.

Agilent Technologies

For more information on Agilent Technologies’

products, applications or services, please con-

tact your local Agilent office. The complete list

is available at:

/find/contactus

Phone or Fax

United States:

(tel) 800 829 4444

(fax) 800 829 4433

Canada:

(tel) 877 894 4414

(fax) 800 746 4866

China:

(tel) 800 810 0189

(fax) 800 820 2816

Europe:

(tel) 31 20 547 2111

Japan:

(tel) (81) 426 56 7832

(fax) (81) 426 56 7840

Korea:

(tel) (080) 769 0800

(fax) (080) 769 0900

Latin America:

(tel) (305) 269 7500

Taiwan:

(tel) 0800 047 866

(fax) 0800 286 331

Other Asia Pacific Countries:

(tel) (65) 6375 8100

(fax) (65) 6755 0042

Email:*****************

Product specifications and descriptions in this

document subject to change without notice.

© Agilent Technologies, Inc. 2006

Printed in USA, 29 September, 2006

5989-5762EN

4

U2905AU2355AU2905A

2024年8月4日发(作者:纪雪莲)

U2905AU2355AU2905A

Agilent U2781A

Features

• 6USB module slots

•Simultaneous Synchronization

(SSI)

•Star Trigger

•Internal and external 10 MHz

reference clock

•Trigger in and trigger out signals

•SCPI commands

•IVI-COM driver compatibility

•USB TMC 488.2 Standards

compliant

•USB 2.0 high speed interface

•Rackmount kit available as an

option

6-slot USB Modular Instrument

Chassis

Data Sheet

Introduction

USB modules and the external trigger

Agilent U2781A USB Modular Instrument

signal. The star trigger bus is a dedicated

Chassis is a 4U height chassis with 6 USB

trigger lines between the external trigger

module slots. It is a portable chassis with

input and USB slots. Users can achieve

high performance added value. It targets a

precise trigger between each USB modules

wide range of applications in both industrial

via the synchronization routing of the star

and scientific environments. It helps you

trigger.

lower your cost of test and accelerate your

test system integration and development.

USB backplane

The USB backplane provides a means to

The Agilent U2781A comes with USB plug

synchronize the modules.

and play connectivity. The USB interface

that is compliant with the USBTMC 488.2

Additional Features

Standards works seamlessly with Agilent

A 10MHz system reference clock is

Measurement Manager software and can

supplied to each modules slots. There are

be controlled remotely via industry standard

two temperature sensors and a monitoring

SCPI commands. In addition, the U2781A

fan control circuit to monitor the internal

USB modular instrument chassis comes

temperature and speed of the fans. The fans

with Agilent IO Libraries Suite 14.2. The IO

are mainly used for heat dissipation.

Libraries provide robust instrument control

The chassis also provides external 10MHz

and work with the software development

reference clock, external trigger in and

environment you choose. IVI-COM driver is

trigger out functions via BNC connectors at

also included to ensure an easy integration

the rear panel.

and compatibility with different

programming environments.

Star trigger bus

The U2781A USB modular instrument

chassis comes with star trigger bus, which

offers precise synchronization between

Agilent Technologies

1

ELECTRICAL SPECIFICATIONS

Power Supply AC Input

Input voltage range

Input frequency range

Input current rating

Effiency

Power Supply DC Output

Output rated voltage

Max output rated current

Max output rated power

Over voltage protection

Internal 10 MHz Reference Clock

Accuracy

Slot to slot skew

External 10 MHz Reference Clock

Auto detection level

Input frequency range

Input magnitude

Input impedance

Damage level

External Trigger In

Compatibility

V

IH

(Positive threshold voltage)

V

IL

(Negative threshold voltage)

Hold time

Input voltage range

Slot to slot skew

External Trigger Out

V

OH

V

OL

Output voltage range

100 to 240 VAC

50 to 60 Hz

3.5 A/115 VAC; 1.7 A/230 VAC

75%

12 VDC

16.7 A

200 W

13.2 to 16.2 V

25 ppm for operating range

350 ps

Yes

10 MHz

100 mVpp to 5 Vpp (sine/square wave)

50 Ω ± 5 Ω

10 Vrms

TTL

2.0 V

0.8 V

8 ns pulse width

0 to 5.0 V

350 ps

2.9 V

0.1 V

0 to 3.3 V

MECHANICAL SPECIFICATIONS

Physical Layout

Number of USB module slots

Dimension of each module slot

Dimension of chassis

Weight

Power LED

USB Backplane

Connector

Input signals

Output signal

Cooling Fan

Number of fans

Fan speed

Noise

Power (each fan)

6

25.40 mm (W) x 174.54 mm (D) x 105.00 mm (H)

270.00 mm (W) x 271.20 mm (D) x 197.00 mm (H)

3.7 kg

ON/OFF type

55 pins Ernet male type C

External 10 MHz clock in (BNC connector)

External trigger in (BNC connector)

Trigger out (BNC connector)

2 (at the bottom of the chassis)

3300 rpm ±10%

37 dB(A)

2.52 W

2

GENERAL SPECIFICATIONS

REMOTE INTERFACE

USB 2.0 High Speed

USBTMC Class Device

POWER CONSUMPTION

400 VA maximum

OPERATING ENVIRONMENT

Operating temperature from 0 °C to +55 °C

Relative humidity at 15% to 85% RH (non-condensing)

Altitude up to 4600 meters

STORAGE COMPLIANCE

–20°C to +70°C

SAFETY COMPLIANCE

Certified with:

•IEC 61010-1:2001/EN 61010-1:2001 (2nd Edition)

•USA: UL61010-1: 2004

•Canada: CSA C22.2 No.61010-1:2004

EMC COMPLIANCE

Certified with:

•IEC/EN 61326-1 1998

•CISPR 11: 1990/EN55011:1991 , Group 1, Class A

•CANADA: ICES-001: 1998

•Australia/New Zealand: AS/NZS 2064.1

ACOUSTIC EMISSION

•Sound pressure level: 45.5 dB(A)

•Sound power level: 56.6 dB(A)

SHOCK and VIBRATION

Tested to IEC/EN 60068-2

DIMENSION (WxDxH)

270.00 mm x 271.20 mm x 197.00 mm

WEIGHT

3.7 kg

WARRANTY

One year

SOFTWARE

REQUIREMENT

Agilent connectivity software included

Agilent IO Libraries Suite 14.2

Minimum system requirements (IO libraries and drivers)

PC hardware 500 MHz Pentium III or higher,

256 MB RAM,

40 GB hard disk space, CD-ROM drive

Operating System Windows 2000 or higher

Computer Interface USB 2.0 high speed

Software driver support for programming languages

Software driver : IVI-COM

Compatible with programming environments:

Agilent VEE Pro, Agilent T&M Toolkit

Microsoft Visual , C/C++

Visual Basic 6

LabVIEW

MATLAB

PRODUCT OVERVIEW

FRONT VIEW

197 m

270 mm

REAR VIEW

Standard Shipped Components:

•USB Interface Cable

•Quick Start Guide

•Functional Test Certificate

•Product Reference CD-ROM

•Agilent IO Libraries Suite 14.2 CD-ROM

Optional Accessories:

•U2905A Rackmount Kit for the U2781A 6-slot USB Modular Instrument

Chassis

3

Agilent Technologies’ Test and Measurement Support, Services, and Assistance

Agilent Technologies aims to maximize the value you receive, while minimizing your risk and

problems. We strive to ensure that you get the test and measurement capabilities you paid for

and obtain the support you need. Our extensive support resources and services can help you

choose the right Agilent products for your applications and apply them successfully. Every

instrument and system we sell has a global warranty. Two concepts underlie Agilent’s overall

support policy: “Our Promise” and “Your Advantage.”

Our Promise

Our Promise means your Agilent test and measurement equipment will meet its advertised

performance and functionality. When you are choosing new equipment, we will help you with

product information, including realistic performance specifications and practical

recommendations from experienced test engineers. When you receive your new Agilent

equipment, we can help verify that it works properly and help with initial product operation.

Your Advantage

Your Advantage means that Agilent offers a wide range of additional expert test and

measurement services, which you can purchase according to your unique technical and

business needs. Solve problems efficiently and gain a competitive edge by contracting with us

for calibration, extra-cost upgrades, out-of-warranty repairs, and on-site education and training,

as well as design, system integration, project management, and other professional engineering

services. Experienced Agilent engineers and technicians worldwide can help you maximize your

productivity, optimize the return on investment of your Agilent instruments and systems, and

obtain dependable measurement accuracy for the life of those products.

Agilent Email Updates

/find/emailupdates

Get the latest information on the products and applications you select.

Agilent Direct

/find/agilentdirect

Quickly choose and use your test equipment solutions with confidence.

Agilent Technologies

For more information on Agilent Technologies’

products, applications or services, please con-

tact your local Agilent office. The complete list

is available at:

/find/contactus

Phone or Fax

United States:

(tel) 800 829 4444

(fax) 800 829 4433

Canada:

(tel) 877 894 4414

(fax) 800 746 4866

China:

(tel) 800 810 0189

(fax) 800 820 2816

Europe:

(tel) 31 20 547 2111

Japan:

(tel) (81) 426 56 7832

(fax) (81) 426 56 7840

Korea:

(tel) (080) 769 0800

(fax) (080) 769 0900

Latin America:

(tel) (305) 269 7500

Taiwan:

(tel) 0800 047 866

(fax) 0800 286 331

Other Asia Pacific Countries:

(tel) (65) 6375 8100

(fax) (65) 6755 0042

Email:*****************

Product specifications and descriptions in this

document subject to change without notice.

© Agilent Technologies, Inc. 2006

Printed in USA, 29 September, 2006

5989-5762EN

4

U2905AU2355AU2905A

发布评论

评论列表 (0)

  1. 暂无评论