2024年9月1日发(作者:冒兰蕙)
A T JUNIPER (LIVERPOOL) Ltd
Juniper 2 x 25 Gallon Compressor Washing Rig
(JMP/CFM56/D/4777/C601)
This rig is all as per our rig JMP/CFM56/D/4777/C200
apart from for the following modifications.
The modifications are as follows:
•
Actuated ball valves replace the existing manual outlet ball valves for remote operation.
•
Remote control with 50m cable complete with Harting fitting for connection to rig.
•
380/440V, 3 phase, 50hz electrical heating system incorporating control circuit for remote operation.
•
Accessory Air Inlet Kit incorporated (JMP/CFM56/D/6612) complete with quick release Stäubli socket
and plug (SM947).
•
Operating instructions and decal set in French.
•
Set of LEAP-1A engine wash probes (JMP/LEAP/D/7028).
•
Taller rear probe storage box to accommodate LEAP-1A probe set.
Modifications to JMP/CFM56/D/4777/C200 Sheet 1 of 8
Operation
The fluid outlet ball valves fitted to each of the tanks have been replaced
with electrically actuated ball valves (220V AC).
These valves can also be operated manually by operation of the Manual /Auto lever on the side
of the valve.
In the auto position the valves are electrically driven.
In the manual position the valve can be operated like any other ball valve
IE: When the T bar handle is in line with the flow, the valve is open and when the T bar handle is across
the direction of flow, the valve is closed.
The control system for heating the tanks to 70
0
C has been modified to supply power to these valves. No
other external power is required to power the valves.
The valves are electrically isolated when the immersion heater ON buttons are pressed IE: During the
heating of the tanks.
A Harting Socket fitted on the underside of the control box enables connection of the remote control
box. A 7 core, 0.75mm, 50m (54.7 yards) cable (5 cores used) has been provided, one end having a
Harting plug for connection to the Harting socket and the other end a connection to the remote
control box.
The remote control box is fitted with two switches, one switch for each valve. Each switch has an open
and closed position for the respective valve. From the moment a switch on the remote control is
operated, it takes 12 seconds before the respective valve is fully open and 12 seconds before it is
fully closed.
Note:
The cable supplied with the Remote Control is for use in the test cell.
Modifications to JMP/CFM56/D/4777/C200 Sheet 2 of 8
Actuated ball valves (SM886)
Actuated ball valves - SM886
Manual/Auto lever Valve ‘T’ bar handle
Modifications to JMP/CFM56/D/4777/C200 Sheet 3 of 8
Electrical Schematic diagrams
Modifications to JMP/CFM56/D/4777/C200 Sheet 4 of 8
Spare parts list.
Article
E1
E1
RCCB
RCCB
Q1
Q2
Q2
Q3
Q4
Q4
Q5
K1
K2
S1
S2
S3
S4
H1
H2
H3
H4
TX
Fabricant
Legrand
Legrand
Schneider
Schneider
Schneider
Schneider
Schneider
Schneider
Schneider
Schneider
Schneider
Schneider
Schneider
Schneider
Schneider
Schneider
Schneider
Schneider
Schneider
Schneider
Schneider
Legrand
Contaclip
Contaclip
Contaclip
Contaclip
Briticent
Iboco
Description
Chassis
Plaque du Chassis
Residuel Courant Disjoncteur 25A 30mA
RCCB Chassis
Porte Isolateur 32Amp
Disjoncteur 3pole 16Amp
Passer Auxiliaire
Disjoncteur 2pole 1Amp
Disjoncteur 3pole 16Amp
Passer Auxiliaire
Disjoncteur 1pole 2Amp
Chauffage Contacteur 25Amp
Chauffage Contacteur 25Amp
Bouton-Poussoir, Rouge
Bouton-Poussoir, Vert
Bouton-Poussoir, Rouge
Bouton-Poussoir, Vert
Vert Lampe
Rouge Lampe
Rouge Lampe
Vert Lampe
160VA Transformaeur
Bornes
Bornes de Terre
Supports d’extremite
Din 35 Rail
Huit façon bloc de la Terre
40x40 Trunking
Cinq Câble de base 4mm SY
Sept Câble de base 4mm YY
SY Cable Glands
Selecteur
Selecteur
Panneua de Commande Distance
Sept Câble de base 0.75mm YY
Han E Series 6 Way Fishe Mâle
Han E Series 6 Way Presse Femelle
prise
fiche
Reference
JMP/SNECMA/D/7059/1
JMP/SNECMA/D/7059/2
JMP/SNECMA/D/7059/3
JMP/SNECMA/D/7059/4
JMP/SNECMA/D/7059/5
JMP/SNECMA/D/7059/6
JMP/SNECMA/D/7059/7
JMP/SNECMA/D/7059/8
JMP/SNECMA/D/7059/9
JMP/SNECMA/D/7059/10
JMP/SNECMA/D/7059/11
JMP/SNECMA/D/7059/12
JMP/SNECMA/D/7059/13
JMP/SNECMA/D/7059/14
JMP/SNECMA/D/7059/15
JMP/SNECMA/D/7059/16
JMP/SNECMA/D/7059/17
JMP/SNECMA/D/7059/18
JMP/SNECMA/D/7059/19
JMP/SNECMA/D/7059/20
JMP/SNECMA/D/7059/21
JMP/SNECMA/D/7059/22
JMP/SNECMA/D/7059/23
JMP/SNECMA/D/7059/24
JMP/SNECMA/D/7059/25
JMP/SNECMA/D/7059/26
JMP/SNECMA/D/7059/27
JMP/SNECMA/D/7059/28
JMP/SNECMA/D/7059/29
JMP/SNECMA/D/7059/30
JMP/SNECMA/D/7059/31
JMP/SNECMA/D/7059/32
JMP/SNECMA/D/7059/33
JMP/SNECMA/D/7059/34
JMP/SNECMA/D/7059/35
JMP/SNECMA/D/7059/36
JMP/SNECMA/D/7059/37
SM947/1
SM947/2
Qte
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
10
2
2
1
1
1
5m
5m
5
1
1
1
50m
1
1
1
1
S5
S6
E2
CMP
Schneider
Schneider
Schneider
Harting
Harting
Stäubli
Stäubli
Modifications to JMP/CFM56/D/4777/C200 Sheet 5 of 8
380/440V. 3 phase, 50hz electrical heating system incorporating control circuit for remote operation.
Shown here is the Harting plug connecting the remote control box to the rig’s control box.
Modifications to JMP/CFM56/D/4777/C200 Sheet 6 of 8
The Accessory Air Inlet Kit (JMP/CFM56/D/6612) enabling the connection of an offboard compressed air
or nitrogen supply.
Modifications to JMP/CFM56/D/4777/C200 Sheet 7 of 8
15
13
4
14
7
12
3
1
2
5
8
13
10
11
12
ACCESSORY INLET KIT
Item
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Description
⁄
8
” BSPT Filter housing
Pro filter element
3
⁄
8
”x
1
⁄
4
”BSP Adaptor
Nitrogen regulator
5mm x 15mm Hex HD BZP
5mm BZP washers
1
⁄
2
” BSP equal elbow
1
⁄
2
” x
1
⁄
2
” BSP Adaptor
1
⁄
2
” x 584mm (23”)Hose assembly
1
⁄
2
” Non-return valve
1
⁄
2
” x
3
⁄
8
” BSP Adaptor
3
⁄
8
” x
3
⁄
8
” BSP equal elbow
3
⁄
8
” x
3
⁄
8
” BSP Adaptor
1
⁄
2
” x
1
⁄
4
” BSP Adaptor
Stäubli connector
3
6
98
Part number
SM749
SM749/1
JMP/STD/A/5352
SM647
Qty
1
1
1
1
2
2
1
2
1
1
2
1
2
1
1
SM052
JMP/STD/A/5289
JMP/RGT/HL/1322
SM050
JMP/STD/A/5353
SM058
JMP/STD/A/5141
JMP/STD/A/1686
SM947
Modifications to JMP/CFM56/D/4777/C200 Sheet 8 of 8
2024年9月1日发(作者:冒兰蕙)
A T JUNIPER (LIVERPOOL) Ltd
Juniper 2 x 25 Gallon Compressor Washing Rig
(JMP/CFM56/D/4777/C601)
This rig is all as per our rig JMP/CFM56/D/4777/C200
apart from for the following modifications.
The modifications are as follows:
•
Actuated ball valves replace the existing manual outlet ball valves for remote operation.
•
Remote control with 50m cable complete with Harting fitting for connection to rig.
•
380/440V, 3 phase, 50hz electrical heating system incorporating control circuit for remote operation.
•
Accessory Air Inlet Kit incorporated (JMP/CFM56/D/6612) complete with quick release Stäubli socket
and plug (SM947).
•
Operating instructions and decal set in French.
•
Set of LEAP-1A engine wash probes (JMP/LEAP/D/7028).
•
Taller rear probe storage box to accommodate LEAP-1A probe set.
Modifications to JMP/CFM56/D/4777/C200 Sheet 1 of 8
Operation
The fluid outlet ball valves fitted to each of the tanks have been replaced
with electrically actuated ball valves (220V AC).
These valves can also be operated manually by operation of the Manual /Auto lever on the side
of the valve.
In the auto position the valves are electrically driven.
In the manual position the valve can be operated like any other ball valve
IE: When the T bar handle is in line with the flow, the valve is open and when the T bar handle is across
the direction of flow, the valve is closed.
The control system for heating the tanks to 70
0
C has been modified to supply power to these valves. No
other external power is required to power the valves.
The valves are electrically isolated when the immersion heater ON buttons are pressed IE: During the
heating of the tanks.
A Harting Socket fitted on the underside of the control box enables connection of the remote control
box. A 7 core, 0.75mm, 50m (54.7 yards) cable (5 cores used) has been provided, one end having a
Harting plug for connection to the Harting socket and the other end a connection to the remote
control box.
The remote control box is fitted with two switches, one switch for each valve. Each switch has an open
and closed position for the respective valve. From the moment a switch on the remote control is
operated, it takes 12 seconds before the respective valve is fully open and 12 seconds before it is
fully closed.
Note:
The cable supplied with the Remote Control is for use in the test cell.
Modifications to JMP/CFM56/D/4777/C200 Sheet 2 of 8
Actuated ball valves (SM886)
Actuated ball valves - SM886
Manual/Auto lever Valve ‘T’ bar handle
Modifications to JMP/CFM56/D/4777/C200 Sheet 3 of 8
Electrical Schematic diagrams
Modifications to JMP/CFM56/D/4777/C200 Sheet 4 of 8
Spare parts list.
Article
E1
E1
RCCB
RCCB
Q1
Q2
Q2
Q3
Q4
Q4
Q5
K1
K2
S1
S2
S3
S4
H1
H2
H3
H4
TX
Fabricant
Legrand
Legrand
Schneider
Schneider
Schneider
Schneider
Schneider
Schneider
Schneider
Schneider
Schneider
Schneider
Schneider
Schneider
Schneider
Schneider
Schneider
Schneider
Schneider
Schneider
Schneider
Legrand
Contaclip
Contaclip
Contaclip
Contaclip
Briticent
Iboco
Description
Chassis
Plaque du Chassis
Residuel Courant Disjoncteur 25A 30mA
RCCB Chassis
Porte Isolateur 32Amp
Disjoncteur 3pole 16Amp
Passer Auxiliaire
Disjoncteur 2pole 1Amp
Disjoncteur 3pole 16Amp
Passer Auxiliaire
Disjoncteur 1pole 2Amp
Chauffage Contacteur 25Amp
Chauffage Contacteur 25Amp
Bouton-Poussoir, Rouge
Bouton-Poussoir, Vert
Bouton-Poussoir, Rouge
Bouton-Poussoir, Vert
Vert Lampe
Rouge Lampe
Rouge Lampe
Vert Lampe
160VA Transformaeur
Bornes
Bornes de Terre
Supports d’extremite
Din 35 Rail
Huit façon bloc de la Terre
40x40 Trunking
Cinq Câble de base 4mm SY
Sept Câble de base 4mm YY
SY Cable Glands
Selecteur
Selecteur
Panneua de Commande Distance
Sept Câble de base 0.75mm YY
Han E Series 6 Way Fishe Mâle
Han E Series 6 Way Presse Femelle
prise
fiche
Reference
JMP/SNECMA/D/7059/1
JMP/SNECMA/D/7059/2
JMP/SNECMA/D/7059/3
JMP/SNECMA/D/7059/4
JMP/SNECMA/D/7059/5
JMP/SNECMA/D/7059/6
JMP/SNECMA/D/7059/7
JMP/SNECMA/D/7059/8
JMP/SNECMA/D/7059/9
JMP/SNECMA/D/7059/10
JMP/SNECMA/D/7059/11
JMP/SNECMA/D/7059/12
JMP/SNECMA/D/7059/13
JMP/SNECMA/D/7059/14
JMP/SNECMA/D/7059/15
JMP/SNECMA/D/7059/16
JMP/SNECMA/D/7059/17
JMP/SNECMA/D/7059/18
JMP/SNECMA/D/7059/19
JMP/SNECMA/D/7059/20
JMP/SNECMA/D/7059/21
JMP/SNECMA/D/7059/22
JMP/SNECMA/D/7059/23
JMP/SNECMA/D/7059/24
JMP/SNECMA/D/7059/25
JMP/SNECMA/D/7059/26
JMP/SNECMA/D/7059/27
JMP/SNECMA/D/7059/28
JMP/SNECMA/D/7059/29
JMP/SNECMA/D/7059/30
JMP/SNECMA/D/7059/31
JMP/SNECMA/D/7059/32
JMP/SNECMA/D/7059/33
JMP/SNECMA/D/7059/34
JMP/SNECMA/D/7059/35
JMP/SNECMA/D/7059/36
JMP/SNECMA/D/7059/37
SM947/1
SM947/2
Qte
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
10
2
2
1
1
1
5m
5m
5
1
1
1
50m
1
1
1
1
S5
S6
E2
CMP
Schneider
Schneider
Schneider
Harting
Harting
Stäubli
Stäubli
Modifications to JMP/CFM56/D/4777/C200 Sheet 5 of 8
380/440V. 3 phase, 50hz electrical heating system incorporating control circuit for remote operation.
Shown here is the Harting plug connecting the remote control box to the rig’s control box.
Modifications to JMP/CFM56/D/4777/C200 Sheet 6 of 8
The Accessory Air Inlet Kit (JMP/CFM56/D/6612) enabling the connection of an offboard compressed air
or nitrogen supply.
Modifications to JMP/CFM56/D/4777/C200 Sheet 7 of 8
15
13
4
14
7
12
3
1
2
5
8
13
10
11
12
ACCESSORY INLET KIT
Item
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Description
⁄
8
” BSPT Filter housing
Pro filter element
3
⁄
8
”x
1
⁄
4
”BSP Adaptor
Nitrogen regulator
5mm x 15mm Hex HD BZP
5mm BZP washers
1
⁄
2
” BSP equal elbow
1
⁄
2
” x
1
⁄
2
” BSP Adaptor
1
⁄
2
” x 584mm (23”)Hose assembly
1
⁄
2
” Non-return valve
1
⁄
2
” x
3
⁄
8
” BSP Adaptor
3
⁄
8
” x
3
⁄
8
” BSP equal elbow
3
⁄
8
” x
3
⁄
8
” BSP Adaptor
1
⁄
2
” x
1
⁄
4
” BSP Adaptor
Stäubli connector
3
6
98
Part number
SM749
SM749/1
JMP/STD/A/5352
SM647
Qty
1
1
1
1
2
2
1
2
1
1
2
1
2
1
1
SM052
JMP/STD/A/5289
JMP/RGT/HL/1322
SM050
JMP/STD/A/5353
SM058
JMP/STD/A/5141
JMP/STD/A/1686
SM947
Modifications to JMP/CFM56/D/4777/C200 Sheet 8 of 8