最新消息: USBMI致力于为网友们分享Windows、安卓、IOS等主流手机系统相关的资讯以及评测、同时提供相关教程、应用、软件下载等服务。

艾顿·莫勒尔NZM类型的三极630A切断器说明书

IT圈 admin 63浏览 0评论

2024年9月8日发(作者:独文敏)

DATASHEET - PN3-630

Switch-disconnector 3p, 630A

Part no.

EL Number

(Norway)

PN3-630

266018

4358917

Eaton Moeller series NZM switch-disconnector

PN3-630

4

159 millimetre

275 millimetre

140 millimetre

4.808 kilogram

RoHS conform

IEC

IEC/EN 60947

NZM

Switch-disconnector

None

Use in unearthed supply systems at 690 V

Switch-disconnector

PN3

Three-pole

630 A

Version as emergency stop installation

Version as maintenance-/service switch

Version as main switch

Main switch characteristics including positive drive to IEC/EN 60204 and VDE 0113.

Isolating characteristics to IEC/EN 60947-3 and VDE 0660.

Busbar tag shroud to VDE 0160 Part 100.

Rated current = rated uninterrupted current: 630 A

690 V - 690 V

690 V

1000 V

6000 V

8000 V

0 kA

630 A (415 V AC-22A, making and breaking capacity)

500 A (415 V AC-23A, making and breaking capacity)

630 A (690 V AC-22A, making and breaking capacity)

500 A (690 V AC-23A, making and breaking capacity)

0 A

0 A

PN3(N3)-400…630: 630 AgGgL

80 kA at 690 V

100 kA at 400/415 V

80 kA at 690 V

PN3(N3)-400…630: 630 AgGgL

100 kA at 400/415 V

12 kA

12 kA

12 kA

50 Hz

25 kA

0 kW

315 kW

General specifications

Product name

Part no.

EAN

Product Length/Depth

Product height

Product width

Product weight

Compliances

Certifications

Product Tradename

Product Type

Product Sub Type

Delivery program

Application

Type

Circuit breaker frame type

Number of poles

Amperage Rating

Features

Special features

Technical Data - Electrical

Voltage rating

Rated operating voltage (Ue) at AC - max

Rated insulation voltage (Ui)

Rated impulse withstand voltage (Uimp) at auxiliary contacts

Rated impulse withstand voltage (Uimp) at main contacts

Rated conditional short-circuit current (Iq)

Rated operational current

Rated permanent current at AC-21, 400 V

Rated permanent current at AC-23, 400 V

Rated conditional short-circuit current with back-up fuse

Rated conditional short-circuit current with downstream fuse

Rated short-time withstand current (Icw)

Rated short-time withstand current (t = 0.3 s)

Rated short-time withstand current (t = 1 s)

Rated operating frequency

Rated short-circuit making capacity Icm at 690 V, 50/60 Hz

Rated operating power at AC-3, 400 V

Rated operating power at AC-23, 400 V

12/14/20231 / 4

Switching power at 400 V

Short-circuit protective device fuses - max

Electrical connection type of main circuit

Isolation

Number of operations per hour - max

Handle type

Overvoltage category

Pollution degree

Lifespan, electrical

0 kW

630 A gL

Screw connection

300 V AC (between the auxiliary contacts)

500 V AC (between auxiliary contacts and main contacts)

60

Rocker lever

III

3

3000 operations at 690 V AC-1

3000 operations at 400 V AC-3

5000 operations at 415 V AC-1

2000 operations at 690 V AC-3

3000 operations at 415 V AC-3

5000 operations at 400 V AC-1

As required

Ground mounting

Intermediate mounting

Fixed

Built-in device fixed built-in technique

Distribution board installation

IP20 (basic protection type, in the area of the HMI devices)

IP20

IP66 (with door coupling rotary handle)

IP40 (with insulating surround)

IP10 (tunnel terminal)

IP00 (terminations, phase isolator and band terminal)

Finger and back-of-hand proof to DIN EN 50274/VDE 0106 part 110

20 g (half-sinusoidal shock 20 ms)

0

0

0

1

Black

I, 0

Damp heat, constant, to IEC 60068-2-78

Damp heat, cyclic, to IEC 60068-2-30

Main switch characteristics including positive drive to IEC/EN 60204 and VDE 0113.

Isolating characteristics to IEC/EN 60947-3 and VDE 0660.

Busbar tag shroud to VDE 0160 Part 100.

Rated current = rated uninterrupted current: 630 A

15000 operations

Screw terminal

Box terminal. Connection on rear. Tunnel terminal

16 mm² (1x) direct at switch rear-side connection

10 mm² - 16 mm² (2x) direct at switch rear-side connection

16 mm² (1x) at tunnel terminal

25 mm² - 185 mm² (1x) at 1-hole tunnel terminal up to 240 mm² depending on the

cable manufacturer.

Max. 30 mm x 10 mm + 30 mm x 5 mm direct at switch rear-side connection

Min. 20 mm x 5 mm direct at switch rear-side connection

M10 at rear-side screw connection

Max. 10 mm x 50 mm (2x) at rear-side width extension

16 mm² (1x) direct at switch rear-side connection

16 mm² (2x) direct at switch rear-side connection

300 mm² (2x) at rear-side width extension

16 mm² (2x) at box terminal

25 mm² - 120 mm² (1x) direct at switch rear-side connection

35 mm² - 240 mm² (1x) at box terminal

25 mm² - 120 mm² (2x) direct at switch rear-side connection

25 mm² - 185 mm² (1x) at 1-hole tunnel terminal

50 mm² - 240 mm² (1x) at 2-hole tunnel terminal

50 mm² - 240 mm² (2x) at 2-hole tunnel terminal

25 mm² - 120 mm² (2x) at box terminal

10 segments of 50 mm x 1 mm (2x) at rear-side width extension

Max. 8 segments of 24 mm x 1 mm (2x) at box terminal

Max. 10 segments of 24 mm x 1 mm + 5 segments of 24 mm x 1 mm

Direction of incoming supply

Technical Data - Mechanical

Mounting Method

Degree of protection

Degree of protection (IP), front side

Degree of protection (terminations)

Protection against direct contact

Shock resistance

Number of auxiliary contacts (change-over contacts)

Number of auxiliary contacts (normally closed contacts)

Number of auxiliary contacts (normally open contacts)

Number of switches

Handle color

Switch positions

Climatic proofing

Special features

Lifespan, mechanical

Technical Data - Mechanical - Terminals

Standard terminals

Optional terminals

Terminal capacity (aluminum solid conductor/cable)

Terminal capacity (aluminum stranded conductor/cable)

Terminal capacity (copper busbar)

Terminal capacity (copper solid conductor/cable)

Terminal capacity (copper stranded conductor/cable)

Terminal capacity (copper strip)

12/14/20232 / 4

Max. 10 segments of 32 mm x 1 mm + 5 segments of 32 mm x 1 mm at rear-side

connection (punched)

Min. 6 segments of 16 mm x 0.8 mm at box terminal

Min. 6 segments of 16 mm x 0.8 mm at rear-side connection (punched)

Design verification as per IEC/EN 61439 - technical data

Rated operational current for specified heat dissipation (In)

Equipment heat dissipation, current-dependent

Ambient operating temperature - min

Ambient operating temperature - max

Ambient storage temperature - min

Ambient storage temperature - max

630 A

107.16 W

-25 °C

70 °C

40 °C

70 °C

Meets the product standard's requirements.

Meets the product standard's requirements.

Meets the product standard's requirements.

Meets the product standard's requirements.

Meets the product standard's requirements.

Does not apply, since the entire switchgear needs to be evaluated.

Does not apply, since the entire switchgear needs to be evaluated.

Meets the product standard's requirements.

Does not apply, since the entire switchgear needs to be evaluated.

Meets the product standard's requirements.

Does not apply, since the entire switchgear needs to be evaluated.

Does not apply, since the entire switchgear needs to be evaluated.

Is the panel builder's responsibility.

Is the panel builder's responsibility.

Is the panel builder's responsibility.

Is the panel builder's responsibility.

Is the panel builder's responsibility.

The panel builder is responsible for the temperature rise calculation. Eaton will

provide heat dissipation data for the devices.

Is the panel builder's responsibility. The specifications for the switchgear must be

observed.

Is the panel builder's responsibility. The specifications for the switchgear must be

observed.

The device meets the requirements, provided the information in the instruction

leaflet (IL) is observed.

Interlockable

Disconnectors/main switches

Design verification as per IEC/EN 61439

10.2.2 Corrosion resistance

10.2.3.1 Verification of thermal stability of enclosures

10.2.3.2 Verification of resistance of insulating materials to normal heat

10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects

10.2.4 Resistance to ultra-violet (UV) radiation

10.2.5 Lifting

10.2.6 Mechanical impact

10.2.7 Inscriptions

10.3 Degree of protection of assemblies

10.4 Clearances and creepage distances

10.5 Protection against electric shock

10.6 Incorporation of switching devices and components

10.7 Internal electrical circuits and connections

10.8 Connections for external conductors

10.9.2 Power-frequency electric strength

10.9.3 Impulse withstand voltage

10.9.4 Testing of enclosures made of insulating material

10.10 Temperature rise

10.11 Short-circuit rating

10.12 Electromagnetic compatibility

10.13 Mechanical function

Additional information

Functions

Technical data ETIM 8.0

Low-voltage industrial components (EG000017) / Switch disconnector (EC000216)

Electricengineering,automation,processcontrolengineering/Low-voltageswitchtechnology/Off-loadswitch,circuitbreaker,controlswitch/Switchdisconnector(**********.1-27-37-14-03

[AKF060013])

Version as main switch

Version as maintenance-/service switch

Version as safety switch

Version as emergency stop installation

Version as reversing switch

Number of switches

Max. rated operation voltage Ue AC

Rated operating voltage

Rated permanent current Iu

Rated permanent current at AC-23, 400 V

Rated permanent current at AC-21, 400 V

Rated operation power at AC-3, 400 V

Rated short-time withstand current lcw

Rated operation power at AC-23, 400 V

V

V

A

A

A

kW

kA

kW

Yes

Yes

No

Yes

No

1

690

690 - 690

0

0

0

12

315

3 / 412/14/2023

Switching power at 400 V

Conditioned rated short-circuit current Iq

Number of poles

Number of auxiliary contacts as normally closed contact

Number of auxiliary contacts as normally open contact

Number of auxiliary contacts as change-over contact

Motor drive optional

Motor drive integrated

Voltage release optional

Device construction

Suitable for floor mounting

Suitable for front mounting 4-hole

Suitable for front mounting centre

Suitable for distribution board installation

Suitable for intermediate mounting

Colour control element

Type of control element

Interlockable

Type of electrical connection of main circuit

Degree of protection (IP), front side

Degree of protection (NEMA)

kW

kA

0

0

3

0

0

0

No

No

No

Built-in device fixed built-in technique

Yes

No

No

Yes

Yes

Black

Rocker lever

Yes

Screw connection

IP20

12/14/2023Eaton Industries GmbH

© 04/2023 by Eaton Industries GmbH

4 / 4

2024年9月8日发(作者:独文敏)

DATASHEET - PN3-630

Switch-disconnector 3p, 630A

Part no.

EL Number

(Norway)

PN3-630

266018

4358917

Eaton Moeller series NZM switch-disconnector

PN3-630

4

159 millimetre

275 millimetre

140 millimetre

4.808 kilogram

RoHS conform

IEC

IEC/EN 60947

NZM

Switch-disconnector

None

Use in unearthed supply systems at 690 V

Switch-disconnector

PN3

Three-pole

630 A

Version as emergency stop installation

Version as maintenance-/service switch

Version as main switch

Main switch characteristics including positive drive to IEC/EN 60204 and VDE 0113.

Isolating characteristics to IEC/EN 60947-3 and VDE 0660.

Busbar tag shroud to VDE 0160 Part 100.

Rated current = rated uninterrupted current: 630 A

690 V - 690 V

690 V

1000 V

6000 V

8000 V

0 kA

630 A (415 V AC-22A, making and breaking capacity)

500 A (415 V AC-23A, making and breaking capacity)

630 A (690 V AC-22A, making and breaking capacity)

500 A (690 V AC-23A, making and breaking capacity)

0 A

0 A

PN3(N3)-400…630: 630 AgGgL

80 kA at 690 V

100 kA at 400/415 V

80 kA at 690 V

PN3(N3)-400…630: 630 AgGgL

100 kA at 400/415 V

12 kA

12 kA

12 kA

50 Hz

25 kA

0 kW

315 kW

General specifications

Product name

Part no.

EAN

Product Length/Depth

Product height

Product width

Product weight

Compliances

Certifications

Product Tradename

Product Type

Product Sub Type

Delivery program

Application

Type

Circuit breaker frame type

Number of poles

Amperage Rating

Features

Special features

Technical Data - Electrical

Voltage rating

Rated operating voltage (Ue) at AC - max

Rated insulation voltage (Ui)

Rated impulse withstand voltage (Uimp) at auxiliary contacts

Rated impulse withstand voltage (Uimp) at main contacts

Rated conditional short-circuit current (Iq)

Rated operational current

Rated permanent current at AC-21, 400 V

Rated permanent current at AC-23, 400 V

Rated conditional short-circuit current with back-up fuse

Rated conditional short-circuit current with downstream fuse

Rated short-time withstand current (Icw)

Rated short-time withstand current (t = 0.3 s)

Rated short-time withstand current (t = 1 s)

Rated operating frequency

Rated short-circuit making capacity Icm at 690 V, 50/60 Hz

Rated operating power at AC-3, 400 V

Rated operating power at AC-23, 400 V

12/14/20231 / 4

Switching power at 400 V

Short-circuit protective device fuses - max

Electrical connection type of main circuit

Isolation

Number of operations per hour - max

Handle type

Overvoltage category

Pollution degree

Lifespan, electrical

0 kW

630 A gL

Screw connection

300 V AC (between the auxiliary contacts)

500 V AC (between auxiliary contacts and main contacts)

60

Rocker lever

III

3

3000 operations at 690 V AC-1

3000 operations at 400 V AC-3

5000 operations at 415 V AC-1

2000 operations at 690 V AC-3

3000 operations at 415 V AC-3

5000 operations at 400 V AC-1

As required

Ground mounting

Intermediate mounting

Fixed

Built-in device fixed built-in technique

Distribution board installation

IP20 (basic protection type, in the area of the HMI devices)

IP20

IP66 (with door coupling rotary handle)

IP40 (with insulating surround)

IP10 (tunnel terminal)

IP00 (terminations, phase isolator and band terminal)

Finger and back-of-hand proof to DIN EN 50274/VDE 0106 part 110

20 g (half-sinusoidal shock 20 ms)

0

0

0

1

Black

I, 0

Damp heat, constant, to IEC 60068-2-78

Damp heat, cyclic, to IEC 60068-2-30

Main switch characteristics including positive drive to IEC/EN 60204 and VDE 0113.

Isolating characteristics to IEC/EN 60947-3 and VDE 0660.

Busbar tag shroud to VDE 0160 Part 100.

Rated current = rated uninterrupted current: 630 A

15000 operations

Screw terminal

Box terminal. Connection on rear. Tunnel terminal

16 mm² (1x) direct at switch rear-side connection

10 mm² - 16 mm² (2x) direct at switch rear-side connection

16 mm² (1x) at tunnel terminal

25 mm² - 185 mm² (1x) at 1-hole tunnel terminal up to 240 mm² depending on the

cable manufacturer.

Max. 30 mm x 10 mm + 30 mm x 5 mm direct at switch rear-side connection

Min. 20 mm x 5 mm direct at switch rear-side connection

M10 at rear-side screw connection

Max. 10 mm x 50 mm (2x) at rear-side width extension

16 mm² (1x) direct at switch rear-side connection

16 mm² (2x) direct at switch rear-side connection

300 mm² (2x) at rear-side width extension

16 mm² (2x) at box terminal

25 mm² - 120 mm² (1x) direct at switch rear-side connection

35 mm² - 240 mm² (1x) at box terminal

25 mm² - 120 mm² (2x) direct at switch rear-side connection

25 mm² - 185 mm² (1x) at 1-hole tunnel terminal

50 mm² - 240 mm² (1x) at 2-hole tunnel terminal

50 mm² - 240 mm² (2x) at 2-hole tunnel terminal

25 mm² - 120 mm² (2x) at box terminal

10 segments of 50 mm x 1 mm (2x) at rear-side width extension

Max. 8 segments of 24 mm x 1 mm (2x) at box terminal

Max. 10 segments of 24 mm x 1 mm + 5 segments of 24 mm x 1 mm

Direction of incoming supply

Technical Data - Mechanical

Mounting Method

Degree of protection

Degree of protection (IP), front side

Degree of protection (terminations)

Protection against direct contact

Shock resistance

Number of auxiliary contacts (change-over contacts)

Number of auxiliary contacts (normally closed contacts)

Number of auxiliary contacts (normally open contacts)

Number of switches

Handle color

Switch positions

Climatic proofing

Special features

Lifespan, mechanical

Technical Data - Mechanical - Terminals

Standard terminals

Optional terminals

Terminal capacity (aluminum solid conductor/cable)

Terminal capacity (aluminum stranded conductor/cable)

Terminal capacity (copper busbar)

Terminal capacity (copper solid conductor/cable)

Terminal capacity (copper stranded conductor/cable)

Terminal capacity (copper strip)

12/14/20232 / 4

Max. 10 segments of 32 mm x 1 mm + 5 segments of 32 mm x 1 mm at rear-side

connection (punched)

Min. 6 segments of 16 mm x 0.8 mm at box terminal

Min. 6 segments of 16 mm x 0.8 mm at rear-side connection (punched)

Design verification as per IEC/EN 61439 - technical data

Rated operational current for specified heat dissipation (In)

Equipment heat dissipation, current-dependent

Ambient operating temperature - min

Ambient operating temperature - max

Ambient storage temperature - min

Ambient storage temperature - max

630 A

107.16 W

-25 °C

70 °C

40 °C

70 °C

Meets the product standard's requirements.

Meets the product standard's requirements.

Meets the product standard's requirements.

Meets the product standard's requirements.

Meets the product standard's requirements.

Does not apply, since the entire switchgear needs to be evaluated.

Does not apply, since the entire switchgear needs to be evaluated.

Meets the product standard's requirements.

Does not apply, since the entire switchgear needs to be evaluated.

Meets the product standard's requirements.

Does not apply, since the entire switchgear needs to be evaluated.

Does not apply, since the entire switchgear needs to be evaluated.

Is the panel builder's responsibility.

Is the panel builder's responsibility.

Is the panel builder's responsibility.

Is the panel builder's responsibility.

Is the panel builder's responsibility.

The panel builder is responsible for the temperature rise calculation. Eaton will

provide heat dissipation data for the devices.

Is the panel builder's responsibility. The specifications for the switchgear must be

observed.

Is the panel builder's responsibility. The specifications for the switchgear must be

observed.

The device meets the requirements, provided the information in the instruction

leaflet (IL) is observed.

Interlockable

Disconnectors/main switches

Design verification as per IEC/EN 61439

10.2.2 Corrosion resistance

10.2.3.1 Verification of thermal stability of enclosures

10.2.3.2 Verification of resistance of insulating materials to normal heat

10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects

10.2.4 Resistance to ultra-violet (UV) radiation

10.2.5 Lifting

10.2.6 Mechanical impact

10.2.7 Inscriptions

10.3 Degree of protection of assemblies

10.4 Clearances and creepage distances

10.5 Protection against electric shock

10.6 Incorporation of switching devices and components

10.7 Internal electrical circuits and connections

10.8 Connections for external conductors

10.9.2 Power-frequency electric strength

10.9.3 Impulse withstand voltage

10.9.4 Testing of enclosures made of insulating material

10.10 Temperature rise

10.11 Short-circuit rating

10.12 Electromagnetic compatibility

10.13 Mechanical function

Additional information

Functions

Technical data ETIM 8.0

Low-voltage industrial components (EG000017) / Switch disconnector (EC000216)

Electricengineering,automation,processcontrolengineering/Low-voltageswitchtechnology/Off-loadswitch,circuitbreaker,controlswitch/Switchdisconnector(**********.1-27-37-14-03

[AKF060013])

Version as main switch

Version as maintenance-/service switch

Version as safety switch

Version as emergency stop installation

Version as reversing switch

Number of switches

Max. rated operation voltage Ue AC

Rated operating voltage

Rated permanent current Iu

Rated permanent current at AC-23, 400 V

Rated permanent current at AC-21, 400 V

Rated operation power at AC-3, 400 V

Rated short-time withstand current lcw

Rated operation power at AC-23, 400 V

V

V

A

A

A

kW

kA

kW

Yes

Yes

No

Yes

No

1

690

690 - 690

0

0

0

12

315

3 / 412/14/2023

Switching power at 400 V

Conditioned rated short-circuit current Iq

Number of poles

Number of auxiliary contacts as normally closed contact

Number of auxiliary contacts as normally open contact

Number of auxiliary contacts as change-over contact

Motor drive optional

Motor drive integrated

Voltage release optional

Device construction

Suitable for floor mounting

Suitable for front mounting 4-hole

Suitable for front mounting centre

Suitable for distribution board installation

Suitable for intermediate mounting

Colour control element

Type of control element

Interlockable

Type of electrical connection of main circuit

Degree of protection (IP), front side

Degree of protection (NEMA)

kW

kA

0

0

3

0

0

0

No

No

No

Built-in device fixed built-in technique

Yes

No

No

Yes

Yes

Black

Rocker lever

Yes

Screw connection

IP20

12/14/2023Eaton Industries GmbH

© 04/2023 by Eaton Industries GmbH

4 / 4

发布评论

评论列表 (0)

  1. 暂无评论