Time Switches ( TB 100 Series )

Panasonic Brand Time Switches have been utilized

worldwide to provide the benefits of Aromat/

Panasonic Electric Works Corporation of America

quality and innovative designs. The TB100 Series

products are user friendly, extremely durable and

provide the opportunity to save valuable energy

dollars in a wide array of applications:

• Interior/Exterior Lighting

• Heating/Ventilating Systems

• Sign/Display Lighting

• Pool Heaters

• Signal Systems

• Fans

• Conveyors

• Air Conditioners

• Filters

• Pumps

• Refrigeration

• Any Many Others!

Features and Benefits:

Enclosure – NEMA 3R

(Plastic for indoor/outdoor uses)

• 15 minute intervals –

Up to 96 ON/OFF operations per day

• Permanent time setting points –

easy ON/OFF time setting

• Direct view clock face

• Durable lightweight and thin design plastic enclosure,

commonly used for indoor and outdoor applications

• Ground terminal screw is provided for easy connection

• Limited one-year warranty for repair or replacement.

Specifications:

Model Number

Type

Rated AC Voltage

Rated Frequency

Switch

Switch Rating

General Purpose

Tungsten

Motor

Minimal Applicable load

TB1001RTB1002RTB1003RTB1004R

24 hour dial

128-277

60 Hz (AC Synchronous Motor)

SPST (NO) DPST(NO)

Separate Circuit - Voltage is not applied to the load circuit

30A 277V AC

15A 125V AC, 5A 250V AC

1 HP 125V AC, 2HP 250V AC

100 mA 12V DC

Operations

Manual

Time Setting

Minimal Unit Time

Minimal Interval

Maximum Operations

ON/AUTO/OFF Switch

Built-in Time Setting Pins

15 minutes

15 minutes

96 ON/OFF per day

Less than 95% (Non-condensing)

NEMA 3R (Plastic for indoor/outdoor uses)

Ambient Humidity

Enclosure

Shipping Weight

Standard

Warranty

1.56 lbs.1.58 lbs.1.65 lbs.1.67 lbs.

UL/CUL

Limited one-year for repair or replacement.

Visit our Web Site:

Wiring Diagram

TB1001R

SPST

120VAC

60Hz

TB1002R

SPST

208-277VAC

60Hz

208-277VAC

60Hz

SUPPLY

120VAC

60Hz

SUPPLY

TB1003R

DPST

120VAC

60Hz

TB1004R

DPST

208-277VAC

60Hz

SINGLE-PHASE;

THREE WIRE

SUPPLY

208-277VAC

60Hz

SUPPLY

Dimensions - Millimeters / Inches

140.5 / 5

17

32

45.3 / 1

25

32

5

4

/

2

1

8

6

9

.

5

/

2

4

7

6

4

1

4

5

/

5

4

5

6

4

4

5

.

3

/

1

2

5

3

2

Ø

8

/

Ø

5

1

6

9

/

2

3

6

4

5

9

/

2

2

1

6

4

1

9

3

.

5

/

7

5

8

1

9

6

.

5

/

7

4

7

6

4

2

0

9

.

5

/

8

1

4

2

8

.

5

/

1

1

8

6

0

.

5

/

2

3

8

NOTE:

For additional installation

and operational information,

please refer to the Operating

Instructions.

152 / 5

63

64

54 / 2⁄

69.5 / 2

47

64

1

8

30 / 1

3

16

47.3 / 1

55

64

63.5 / 2

1

2

Operating Instructions

Parts Designation

To set “On” and “Off” Times

Time span unit of single TIME-SET PIN is 15 minutes. If it is set

toward outside of the DIAL, it turns the load(s) “ON”. If set toward

inside, it turns the load(s) “OFF”. If you need ON-time or OFF-time

longer than 15 minutes, additional TIME-SET PINs should be set

accordingly.

Examples:

If you need ON-timer for 45 minutes (ON at 10:00

AM

and OFF at 10:45

AM

) in the drawing at right, three TIME-SET PINs

shall be set toward the outside.

Notes:

Do not set the four TIME-SET PINs on both sides of TIME

INDICATOR ( ). When desired times overlap these sections, turn

the MINUTE DIAL in the direction of the ARROW, then set the

TIME-SET PINs.

To set Time-of-Day

Rotate the MINUTE DIAL in the direction of the ARROW to set the

exact time-of-day.

Notes: Do not turn counter-clockwise. Forcibly turning the MINUTE

DIAL in reverse or directly turning the DIAL may cause failure of the

Time Switch.

For Manual Operation

Shift the MANUAL SWITCH to the AUTO position to turn the load(s)

“ON” and “OFF” according to the TIME-SET PINs.

Shift the MANUAL SWITCH to the ON position to turn the load(s)

“ON” or to the OFF position to turn the load(s) “OFF” regardless of

the TIME-SET PINs.

ARROW MARK

TIME-SET PINs

MANUAL SWITCH

FRONT COVER

MINUTE DIAL

TIME

INDICATOR

DIAL

INPUT TERMINALs

FOR POWER

PANEL SCREW

INSULATING PANEL

OUTPUT

TERMINALS

FOR LOAD(s)

GROUNDING

TERMINAL

Panasonic Electric Works Corporation of America

629 Central Avenue, New Providence, NJ 07974 Tel:908-464-3550 Fax:908-771-5656

3M298

3

0

/

1

3

1

6

4

7

.

3

/

1

5

5

6

4

48 / 1

7

8

124.5 / 4

29

32

127.5 / 5

1

32

2024年9月8日发(作者:盈芷蝶)

Time Switches ( TB 100 Series )

Panasonic Brand Time Switches have been utilized

worldwide to provide the benefits of Aromat/

Panasonic Electric Works Corporation of America

quality and innovative designs. The TB100 Series

products are user friendly, extremely durable and

provide the opportunity to save valuable energy

dollars in a wide array of applications:

• Interior/Exterior Lighting

• Heating/Ventilating Systems

• Sign/Display Lighting

• Pool Heaters

• Signal Systems

• Fans

• Conveyors

• Air Conditioners

• Filters

• Pumps

• Refrigeration

• Any Many Others!

Features and Benefits:

Enclosure – NEMA 3R

(Plastic for indoor/outdoor uses)

• 15 minute intervals –

Up to 96 ON/OFF operations per day

• Permanent time setting points –

easy ON/OFF time setting

• Direct view clock face

• Durable lightweight and thin design plastic enclosure,

commonly used for indoor and outdoor applications

• Ground terminal screw is provided for easy connection

• Limited one-year warranty for repair or replacement.

Specifications:

Model Number

Type

Rated AC Voltage

Rated Frequency

Switch

Switch Rating

General Purpose

Tungsten

Motor

Minimal Applicable load

TB1001RTB1002RTB1003RTB1004R

24 hour dial

128-277

60 Hz (AC Synchronous Motor)

SPST (NO) DPST(NO)

Separate Circuit - Voltage is not applied to the load circuit

30A 277V AC

15A 125V AC, 5A 250V AC

1 HP 125V AC, 2HP 250V AC

100 mA 12V DC

Operations

Manual

Time Setting

Minimal Unit Time

Minimal Interval

Maximum Operations

ON/AUTO/OFF Switch

Built-in Time Setting Pins

15 minutes

15 minutes

96 ON/OFF per day

Less than 95% (Non-condensing)

NEMA 3R (Plastic for indoor/outdoor uses)

Ambient Humidity

Enclosure

Shipping Weight

Standard

Warranty

1.56 lbs.1.58 lbs.1.65 lbs.1.67 lbs.

UL/CUL

Limited one-year for repair or replacement.

Visit our Web Site:

Wiring Diagram

TB1001R

SPST

120VAC

60Hz

TB1002R

SPST

208-277VAC

60Hz

208-277VAC

60Hz

SUPPLY

120VAC

60Hz

SUPPLY

TB1003R

DPST

120VAC

60Hz

TB1004R

DPST

208-277VAC

60Hz

SINGLE-PHASE;

THREE WIRE

SUPPLY

208-277VAC

60Hz

SUPPLY

Dimensions - Millimeters / Inches

140.5 / 5

17

32

45.3 / 1

25

32

5

4

/

2

1

8

6

9

.

5

/

2

4

7

6

4

1

4

5

/

5

4

5

6

4

4

5

.

3

/

1

2

5

3

2

Ø

8

/

Ø

5

1

6

9

/

2

3

6

4

5

9

/

2

2

1

6

4

1

9

3

.

5

/

7

5

8

1

9

6

.

5

/

7

4

7

6

4

2

0

9

.

5

/

8

1

4

2

8

.

5

/

1

1

8

6

0

.

5

/

2

3

8

NOTE:

For additional installation

and operational information,

please refer to the Operating

Instructions.

152 / 5

63

64

54 / 2⁄

69.5 / 2

47

64

1

8

30 / 1

3

16

47.3 / 1

55

64

63.5 / 2

1

2

Operating Instructions

Parts Designation

To set “On” and “Off” Times

Time span unit of single TIME-SET PIN is 15 minutes. If it is set

toward outside of the DIAL, it turns the load(s) “ON”. If set toward

inside, it turns the load(s) “OFF”. If you need ON-time or OFF-time

longer than 15 minutes, additional TIME-SET PINs should be set

accordingly.

Examples:

If you need ON-timer for 45 minutes (ON at 10:00

AM

and OFF at 10:45

AM

) in the drawing at right, three TIME-SET PINs

shall be set toward the outside.

Notes:

Do not set the four TIME-SET PINs on both sides of TIME

INDICATOR ( ). When desired times overlap these sections, turn

the MINUTE DIAL in the direction of the ARROW, then set the

TIME-SET PINs.

To set Time-of-Day

Rotate the MINUTE DIAL in the direction of the ARROW to set the

exact time-of-day.

Notes: Do not turn counter-clockwise. Forcibly turning the MINUTE

DIAL in reverse or directly turning the DIAL may cause failure of the

Time Switch.

For Manual Operation

Shift the MANUAL SWITCH to the AUTO position to turn the load(s)

“ON” and “OFF” according to the TIME-SET PINs.

Shift the MANUAL SWITCH to the ON position to turn the load(s)

“ON” or to the OFF position to turn the load(s) “OFF” regardless of

the TIME-SET PINs.

ARROW MARK

TIME-SET PINs

MANUAL SWITCH

FRONT COVER

MINUTE DIAL

TIME

INDICATOR

DIAL

INPUT TERMINALs

FOR POWER

PANEL SCREW

INSULATING PANEL

OUTPUT

TERMINALS

FOR LOAD(s)

GROUNDING

TERMINAL

Panasonic Electric Works Corporation of America

629 Central Avenue, New Providence, NJ 07974 Tel:908-464-3550 Fax:908-771-5656

3M298

3

0

/

1

3

1

6

4

7

.

3

/

1

5

5

6

4

48 / 1

7

8

124.5 / 4

29

32

127.5 / 5

1

32

发布评论

评论列表 (0)

  1. 暂无评论