最新消息: USBMI致力于为网友们分享Windows、安卓、IOS等主流手机系统相关的资讯以及评测、同时提供相关教程、应用、软件下载等服务。

爱立信Moeller系列Rapid Link速控器(产品编号:198773)说明书

IT圈 admin 14浏览 0评论

2024年10月6日发(作者:巨清嘉)

Eaton 198773

Eaton Moeller® series Rapid Link - Speed controllers, 4.3 A, 1.5

kW, Sensor input 4, 180/207 V DC, AS-Interface®, S-7.4 for 31

modules, HAN Q4/2, STO (Safe Torque Off)

General specifications

Product NameCatalog Number

Eaton Moeller® series Rapid Link Speed 198773

controller

EAN

4

Product Length/Depth

157 mm

Product Width

220 mm

Certifications

IEC/EN 61800-5-1

RoHS

UL approval

UL 61800-5-1

CE

Product Height

270 mm

Product Weight

3.42 kg

Catalog Notes

can be switched

over from U/f to

(vector) speed

control

Connection of

supply voltage

via adapter

cable on round

or flexible

busbar junction

Diagnostics and

reset on device

and via AS-

Interface

Four fixed

speeds

integrated PTC

thermistor

Features

Parameterization: drivesConnect mobile (App)

Diagnostics and reset on device and via AS-Interface

Parameterization: Keypad

Parameterization: drivesConnect

Parameterization: Fieldbus

Fitted with:

Key switch position OFF/RESET

Key switch position HAND

PC connection

Control unit

Internal DC link

Four fixed speeds

IGBT inverter

Key switch position AUTO

Thermo-click with safe isolation

Two sensor inputs through M12 sockets (max. 150 mA) for quick

stop and interlocked manual operation

Selector switch (Positions: REV - OFF - FWD)

PTC thermistor monitoring

Functions

STO (Safe Torque Off)

For actuation of motors with mechanical brake

Mounting position

Vertical

Shock resistance

15 g, Mechanical, According to IEC/EN 60068-2-27, 11 ms, Half-

sinusoidal shock 11 ms, 1000 shocks per shaft

Vibration

Resistance: 57 Hz, Amplitude transition frequency on

acceleration

Resistance: 10 - 150 Hz, Oscillation frequency

Resistance: According to IEC/EN 60068-2-6

Resistance: 6 Hz, Amplitude 0.15 mm

Degree of protection

IP65

NEMA 12

Electromagnetic compatibility

1st and 2nd environments (according to EN 61800-3)

Overvoltage category

III

Product category

Speed controller

Protocol

ASI

AS-Interface profile cable: S-7.4 for 31 modules

Radio interference class

C1: for conducted emissions only

C2, C3: depending on the motor cable length, the connected

load, and ambient conditions. External radio interference

suppression filters (optional) may be necessary.

Rated impulse withstand voltage (Uimp)

2000 V

System configuration type

Center-point earthed star network (TN-S network)

AC voltage

Phase-earthed AC supply systems are not permitted.

Altitude

Max. 2000 m

Above 1000 m with 1 % performance reduction per 100 m

Ambient operating temperature - min

-10 °C

Ambient operating temperature - max

40 °C

Ambient storage temperature - min

-40 °C

Ambient storage temperature - max

70 °C

Climatic proofing

< 95 %, no condensation

In accordance with IEC/EN 50178

Current limitation

0.4 - 4.3 A, motor, main circuit

Adjustable, motor, main circuit

Delay time

< 10 ms, On-delay

< 10 ms, Off-delay

Efficiency

98 % (η)

Input current ILN at 150% overload

4.1 A

Leakage current at ground IPE - max

3.5 mA

Mains current distortion

120 %

Mains switch-on frequency

Maximum of one time every 60 seconds

Mains voltage - min

380 V

Mains voltage - max

480 V

Mains voltage tolerance

380 - 480 V (-10 %/+10 %, at 50/60 Hz)

Operating mode

Sensorless vector control (SLV)

U/f control

BLDC motors

PM and LSPM motors

Synchronous reluctance motors

Output frequency - min

0 Hz

Output frequency - max

500 Hz

Overload current

At 40 °C

For 60 s every 600 s

Overload current IL at 150% overload

6.5 A

Rated frequency - min

45 Hz

Rated frequency - max

66 Hz

Rated operational power at 380/400 V, 50 Hz, 3-phase

1.5 kW

Rated operational voltage

480 V AC, 3-phase

400 V AC, 3-phase

Resolution

0.1 Hz (Frequency resolution, setpoint value)

Starting current - max

200 %, IH, max. starting current (High Overload), For 2 seconds

every 20 seconds, Power section

Supply frequency

50/60 Hz

Switching frequency

8 kHz, 4 - 32 kHz adjustable, fPWM, Power section, Main circuit

System configuration type

Center-point earthed star network (TN-S network)

AC voltage

Phase-earthed AC supply systems are not permitted.

Communication interface

AS-Interface

Connection

Plug type: HAN Q4/2

Interfaces

Specification: S-7.4 (AS-Interface®)

Number of slave addresses: 31 (AS-Interface®)

Max. total power consumption from AS-Interface® power supply

unit (30 V): 190 mA

Assigned motor power at 460/480 V, 60 Hz, 3-phase

2 HP

Braking current

≤ 0.6 A (max. 6 A for 120 ms), Actuator for

external motor brake

Braking torque

≤ 30 % (I/Ie)

Adjustable to 100 % (I/Ie), DC - Main circuit

Braking voltage

280/207 V DC -15 % / +10 %, Actuator for external motor brake

Rated conditional short-circuit current (Iq)

10 kA

Short-circuit protection (external output circuits)

Type 1 coordination via the power bus' feeder unit, Main circuit

Rated control voltage (Uc)

180/207 V DC (external brake 50/60 Hz)

24 V DC (-15 %/+20 %, external via AS-Interface® plug)

Cable length

C3 ≤ 25 m, maximum motor cable length

C1 ≤ 1 m, maximum motor cable length

C2 ≤ 5 m, maximum motor cable length

10.2.2 Corrosion resistance

Meets the product standard's requirements.

10.2.3.1 Verification of thermal stability of enclosures

Meets the product standard's requirements.

10.2.3.2 Verification of resistance of insulating materials to

normal heat

Meets the product standard's requirements.

10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal

elect. effects

Meets the product standard's requirements.

10.2.4 Resistance to ultra-violet (UV) radiation

Meets the product standard's requirements.

10.2.5 Lifting

Does not apply, since the entire switchgear needs to be

evaluated.

10.2.6 Mechanical impact

Does not apply, since the entire switchgear needs to be

evaluated.

10.2.7 Inscriptions

Meets the product standard's requirements.

10.3 Degree of protection of assemblies

Does not apply, since the entire switchgear needs to be

evaluated.

10.4 Clearances and creepage distances

Meets the product standard's requirements.

10.5 Protection against electric shock

Does not apply, since the entire switchgear needs to be

evaluated.

10.6 Incorporation of switching devices and components

Does not apply, since the entire switchgear needs to be

evaluated.

10.7 Internal electrical circuits and connections

Is the panel builder's responsibility.

10.8 Connections for external conductors

Is the panel builder's responsibility.

10.9.2 Power-frequency electric strength

Is the panel builder's responsibility.

10.9.3 Impulse withstand voltage

Is the panel builder's responsibility.

10.9.4 Testing of enclosures made of insulating material

Is the panel builder's responsibility.

Application notes

Connecting drives to generator supplies

Electromagnetic compatibility (EMC)

Generation Change RA-SP to RASP5

Generation change RAMO4 to RAMO5

Generation change from RA-MO to RAMO 4.0

Generation change from RA-SP to RASP 4.0

Configuration to Rockwell PLC for Rapid Link

Generation Change RASP4 to RASP5

Brochures

Rapid Link 5 - brochure

DA-SW-drivesConnect - installation help

DA-SW-USB Driver PC Cable DX-CBL-PC-1M5

DA-SW-Driver DX-CBL-PC-3M0

DA-SW-drivesConnect - Installationshilfe

DA-SW-USB Driver DX-COM-STICK3-KIT

DA-SW-drivesConnect USB Driver DX-COM-PCKIT

DA-SW-drivesConnect

Material handling applications - airports, warehouses and intra-logistics

Catalogues

Product Range Catalog Drives Engineering-EN

Product Range Catalog Drives Engineering

Certification reports

Drawings

eCAD model

Installation instructions

IL034085ZU

10.10 Temperature rise

The panel builder is responsible for the temperature rise

calculation. Eaton will provide heat dissipation data for the

devices.

10.11 Short-circuit rating

Is the panel builder's responsibility. The specifications for the

switchgear must be observed.

10.12 Electromagnetic compatibility

Is the panel builder's responsibility. The specifications for the

switchgear must be observed.

10.13 Mechanical function

The device meets the requirements, provided the information in

the instruction leaflet (IL) is observed.

Installation videos

Rapid Link 5

Manuals and user guides

MN034004EN

MZ040046_EN

MN040003_EN

mCAD model

ramo5_

rasp5_

Eaton Corporation plc

Eaton House

30 Pembroke Road

Dublin 4, Ireland

Eaton is a registered trademark.

All other trademarks are

© 2023 Eaton. All rights property of their respective

reserved. owners.

/socialmedia

2024年10月6日发(作者:巨清嘉)

Eaton 198773

Eaton Moeller® series Rapid Link - Speed controllers, 4.3 A, 1.5

kW, Sensor input 4, 180/207 V DC, AS-Interface®, S-7.4 for 31

modules, HAN Q4/2, STO (Safe Torque Off)

General specifications

Product NameCatalog Number

Eaton Moeller® series Rapid Link Speed 198773

controller

EAN

4

Product Length/Depth

157 mm

Product Width

220 mm

Certifications

IEC/EN 61800-5-1

RoHS

UL approval

UL 61800-5-1

CE

Product Height

270 mm

Product Weight

3.42 kg

Catalog Notes

can be switched

over from U/f to

(vector) speed

control

Connection of

supply voltage

via adapter

cable on round

or flexible

busbar junction

Diagnostics and

reset on device

and via AS-

Interface

Four fixed

speeds

integrated PTC

thermistor

Features

Parameterization: drivesConnect mobile (App)

Diagnostics and reset on device and via AS-Interface

Parameterization: Keypad

Parameterization: drivesConnect

Parameterization: Fieldbus

Fitted with:

Key switch position OFF/RESET

Key switch position HAND

PC connection

Control unit

Internal DC link

Four fixed speeds

IGBT inverter

Key switch position AUTO

Thermo-click with safe isolation

Two sensor inputs through M12 sockets (max. 150 mA) for quick

stop and interlocked manual operation

Selector switch (Positions: REV - OFF - FWD)

PTC thermistor monitoring

Functions

STO (Safe Torque Off)

For actuation of motors with mechanical brake

Mounting position

Vertical

Shock resistance

15 g, Mechanical, According to IEC/EN 60068-2-27, 11 ms, Half-

sinusoidal shock 11 ms, 1000 shocks per shaft

Vibration

Resistance: 57 Hz, Amplitude transition frequency on

acceleration

Resistance: 10 - 150 Hz, Oscillation frequency

Resistance: According to IEC/EN 60068-2-6

Resistance: 6 Hz, Amplitude 0.15 mm

Degree of protection

IP65

NEMA 12

Electromagnetic compatibility

1st and 2nd environments (according to EN 61800-3)

Overvoltage category

III

Product category

Speed controller

Protocol

ASI

AS-Interface profile cable: S-7.4 for 31 modules

Radio interference class

C1: for conducted emissions only

C2, C3: depending on the motor cable length, the connected

load, and ambient conditions. External radio interference

suppression filters (optional) may be necessary.

Rated impulse withstand voltage (Uimp)

2000 V

System configuration type

Center-point earthed star network (TN-S network)

AC voltage

Phase-earthed AC supply systems are not permitted.

Altitude

Max. 2000 m

Above 1000 m with 1 % performance reduction per 100 m

Ambient operating temperature - min

-10 °C

Ambient operating temperature - max

40 °C

Ambient storage temperature - min

-40 °C

Ambient storage temperature - max

70 °C

Climatic proofing

< 95 %, no condensation

In accordance with IEC/EN 50178

Current limitation

0.4 - 4.3 A, motor, main circuit

Adjustable, motor, main circuit

Delay time

< 10 ms, On-delay

< 10 ms, Off-delay

Efficiency

98 % (η)

Input current ILN at 150% overload

4.1 A

Leakage current at ground IPE - max

3.5 mA

Mains current distortion

120 %

Mains switch-on frequency

Maximum of one time every 60 seconds

Mains voltage - min

380 V

Mains voltage - max

480 V

Mains voltage tolerance

380 - 480 V (-10 %/+10 %, at 50/60 Hz)

Operating mode

Sensorless vector control (SLV)

U/f control

BLDC motors

PM and LSPM motors

Synchronous reluctance motors

Output frequency - min

0 Hz

Output frequency - max

500 Hz

Overload current

At 40 °C

For 60 s every 600 s

Overload current IL at 150% overload

6.5 A

Rated frequency - min

45 Hz

Rated frequency - max

66 Hz

Rated operational power at 380/400 V, 50 Hz, 3-phase

1.5 kW

Rated operational voltage

480 V AC, 3-phase

400 V AC, 3-phase

Resolution

0.1 Hz (Frequency resolution, setpoint value)

Starting current - max

200 %, IH, max. starting current (High Overload), For 2 seconds

every 20 seconds, Power section

Supply frequency

50/60 Hz

Switching frequency

8 kHz, 4 - 32 kHz adjustable, fPWM, Power section, Main circuit

System configuration type

Center-point earthed star network (TN-S network)

AC voltage

Phase-earthed AC supply systems are not permitted.

Communication interface

AS-Interface

Connection

Plug type: HAN Q4/2

Interfaces

Specification: S-7.4 (AS-Interface®)

Number of slave addresses: 31 (AS-Interface®)

Max. total power consumption from AS-Interface® power supply

unit (30 V): 190 mA

Assigned motor power at 460/480 V, 60 Hz, 3-phase

2 HP

Braking current

≤ 0.6 A (max. 6 A for 120 ms), Actuator for

external motor brake

Braking torque

≤ 30 % (I/Ie)

Adjustable to 100 % (I/Ie), DC - Main circuit

Braking voltage

280/207 V DC -15 % / +10 %, Actuator for external motor brake

Rated conditional short-circuit current (Iq)

10 kA

Short-circuit protection (external output circuits)

Type 1 coordination via the power bus' feeder unit, Main circuit

Rated control voltage (Uc)

180/207 V DC (external brake 50/60 Hz)

24 V DC (-15 %/+20 %, external via AS-Interface® plug)

Cable length

C3 ≤ 25 m, maximum motor cable length

C1 ≤ 1 m, maximum motor cable length

C2 ≤ 5 m, maximum motor cable length

10.2.2 Corrosion resistance

Meets the product standard's requirements.

10.2.3.1 Verification of thermal stability of enclosures

Meets the product standard's requirements.

10.2.3.2 Verification of resistance of insulating materials to

normal heat

Meets the product standard's requirements.

10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal

elect. effects

Meets the product standard's requirements.

10.2.4 Resistance to ultra-violet (UV) radiation

Meets the product standard's requirements.

10.2.5 Lifting

Does not apply, since the entire switchgear needs to be

evaluated.

10.2.6 Mechanical impact

Does not apply, since the entire switchgear needs to be

evaluated.

10.2.7 Inscriptions

Meets the product standard's requirements.

10.3 Degree of protection of assemblies

Does not apply, since the entire switchgear needs to be

evaluated.

10.4 Clearances and creepage distances

Meets the product standard's requirements.

10.5 Protection against electric shock

Does not apply, since the entire switchgear needs to be

evaluated.

10.6 Incorporation of switching devices and components

Does not apply, since the entire switchgear needs to be

evaluated.

10.7 Internal electrical circuits and connections

Is the panel builder's responsibility.

10.8 Connections for external conductors

Is the panel builder's responsibility.

10.9.2 Power-frequency electric strength

Is the panel builder's responsibility.

10.9.3 Impulse withstand voltage

Is the panel builder's responsibility.

10.9.4 Testing of enclosures made of insulating material

Is the panel builder's responsibility.

Application notes

Connecting drives to generator supplies

Electromagnetic compatibility (EMC)

Generation Change RA-SP to RASP5

Generation change RAMO4 to RAMO5

Generation change from RA-MO to RAMO 4.0

Generation change from RA-SP to RASP 4.0

Configuration to Rockwell PLC for Rapid Link

Generation Change RASP4 to RASP5

Brochures

Rapid Link 5 - brochure

DA-SW-drivesConnect - installation help

DA-SW-USB Driver PC Cable DX-CBL-PC-1M5

DA-SW-Driver DX-CBL-PC-3M0

DA-SW-drivesConnect - Installationshilfe

DA-SW-USB Driver DX-COM-STICK3-KIT

DA-SW-drivesConnect USB Driver DX-COM-PCKIT

DA-SW-drivesConnect

Material handling applications - airports, warehouses and intra-logistics

Catalogues

Product Range Catalog Drives Engineering-EN

Product Range Catalog Drives Engineering

Certification reports

Drawings

eCAD model

Installation instructions

IL034085ZU

10.10 Temperature rise

The panel builder is responsible for the temperature rise

calculation. Eaton will provide heat dissipation data for the

devices.

10.11 Short-circuit rating

Is the panel builder's responsibility. The specifications for the

switchgear must be observed.

10.12 Electromagnetic compatibility

Is the panel builder's responsibility. The specifications for the

switchgear must be observed.

10.13 Mechanical function

The device meets the requirements, provided the information in

the instruction leaflet (IL) is observed.

Installation videos

Rapid Link 5

Manuals and user guides

MN034004EN

MZ040046_EN

MN040003_EN

mCAD model

ramo5_

rasp5_

Eaton Corporation plc

Eaton House

30 Pembroke Road

Dublin 4, Ireland

Eaton is a registered trademark.

All other trademarks are

© 2023 Eaton. All rights property of their respective

reserved. owners.

/socialmedia

发布评论

评论列表 (0)

  1. 暂无评论