2024年10月6日发(作者:巨清嘉)
Eaton 198773
Eaton Moeller® series Rapid Link - Speed controllers, 4.3 A, 1.5
kW, Sensor input 4, 180/207 V DC, AS-Interface®, S-7.4 for 31
modules, HAN Q4/2, STO (Safe Torque Off)
General specifications
Product NameCatalog Number
Eaton Moeller® series Rapid Link Speed 198773
controller
EAN
4
Product Length/Depth
157 mm
Product Width
220 mm
Certifications
IEC/EN 61800-5-1
RoHS
UL approval
UL 61800-5-1
CE
Product Height
270 mm
Product Weight
3.42 kg
Catalog Notes
can be switched
over from U/f to
(vector) speed
control
Connection of
supply voltage
via adapter
cable on round
or flexible
busbar junction
Diagnostics and
reset on device
and via AS-
Interface
Four fixed
speeds
integrated PTC
thermistor
Features
Parameterization: drivesConnect mobile (App)
Diagnostics and reset on device and via AS-Interface
Parameterization: Keypad
Parameterization: drivesConnect
Parameterization: Fieldbus
Fitted with:
Key switch position OFF/RESET
Key switch position HAND
PC connection
Control unit
Internal DC link
Four fixed speeds
IGBT inverter
Key switch position AUTO
Thermo-click with safe isolation
Two sensor inputs through M12 sockets (max. 150 mA) for quick
stop and interlocked manual operation
Selector switch (Positions: REV - OFF - FWD)
PTC thermistor monitoring
Functions
STO (Safe Torque Off)
For actuation of motors with mechanical brake
Mounting position
Vertical
Shock resistance
15 g, Mechanical, According to IEC/EN 60068-2-27, 11 ms, Half-
sinusoidal shock 11 ms, 1000 shocks per shaft
Vibration
Resistance: 57 Hz, Amplitude transition frequency on
acceleration
Resistance: 10 - 150 Hz, Oscillation frequency
Resistance: According to IEC/EN 60068-2-6
Resistance: 6 Hz, Amplitude 0.15 mm
Degree of protection
IP65
NEMA 12
Electromagnetic compatibility
1st and 2nd environments (according to EN 61800-3)
Overvoltage category
III
Product category
Speed controller
Protocol
ASI
AS-Interface profile cable: S-7.4 for 31 modules
Radio interference class
C1: for conducted emissions only
C2, C3: depending on the motor cable length, the connected
load, and ambient conditions. External radio interference
suppression filters (optional) may be necessary.
Rated impulse withstand voltage (Uimp)
2000 V
System configuration type
Center-point earthed star network (TN-S network)
AC voltage
Phase-earthed AC supply systems are not permitted.
Altitude
Max. 2000 m
Above 1000 m with 1 % performance reduction per 100 m
Ambient operating temperature - min
-10 °C
Ambient operating temperature - max
40 °C
Ambient storage temperature - min
-40 °C
Ambient storage temperature - max
70 °C
Climatic proofing
< 95 %, no condensation
In accordance with IEC/EN 50178
Current limitation
0.4 - 4.3 A, motor, main circuit
Adjustable, motor, main circuit
Delay time
< 10 ms, On-delay
< 10 ms, Off-delay
Efficiency
98 % (η)
Input current ILN at 150% overload
4.1 A
Leakage current at ground IPE - max
3.5 mA
Mains current distortion
120 %
Mains switch-on frequency
Maximum of one time every 60 seconds
Mains voltage - min
380 V
Mains voltage - max
480 V
Mains voltage tolerance
380 - 480 V (-10 %/+10 %, at 50/60 Hz)
Operating mode
Sensorless vector control (SLV)
U/f control
BLDC motors
PM and LSPM motors
Synchronous reluctance motors
Output frequency - min
0 Hz
Output frequency - max
500 Hz
Overload current
At 40 °C
For 60 s every 600 s
Overload current IL at 150% overload
6.5 A
Rated frequency - min
45 Hz
Rated frequency - max
66 Hz
Rated operational power at 380/400 V, 50 Hz, 3-phase
1.5 kW
Rated operational voltage
480 V AC, 3-phase
400 V AC, 3-phase
Resolution
0.1 Hz (Frequency resolution, setpoint value)
Starting current - max
200 %, IH, max. starting current (High Overload), For 2 seconds
every 20 seconds, Power section
Supply frequency
50/60 Hz
Switching frequency
8 kHz, 4 - 32 kHz adjustable, fPWM, Power section, Main circuit
System configuration type
Center-point earthed star network (TN-S network)
AC voltage
Phase-earthed AC supply systems are not permitted.
Communication interface
AS-Interface
Connection
Plug type: HAN Q4/2
Interfaces
Specification: S-7.4 (AS-Interface®)
Number of slave addresses: 31 (AS-Interface®)
Max. total power consumption from AS-Interface® power supply
unit (30 V): 190 mA
Assigned motor power at 460/480 V, 60 Hz, 3-phase
2 HP
Braking current
≤ 0.6 A (max. 6 A for 120 ms), Actuator for
external motor brake
Braking torque
≤ 30 % (I/Ie)
Adjustable to 100 % (I/Ie), DC - Main circuit
Braking voltage
280/207 V DC -15 % / +10 %, Actuator for external motor brake
Rated conditional short-circuit current (Iq)
10 kA
Short-circuit protection (external output circuits)
Type 1 coordination via the power bus' feeder unit, Main circuit
Rated control voltage (Uc)
180/207 V DC (external brake 50/60 Hz)
24 V DC (-15 %/+20 %, external via AS-Interface® plug)
Cable length
C3 ≤ 25 m, maximum motor cable length
C1 ≤ 1 m, maximum motor cable length
C2 ≤ 5 m, maximum motor cable length
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to
normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal
elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be
evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be
evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be
evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be
evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be
evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
Application notes
Connecting drives to generator supplies
Electromagnetic compatibility (EMC)
Generation Change RA-SP to RASP5
Generation change RAMO4 to RAMO5
Generation change from RA-MO to RAMO 4.0
Generation change from RA-SP to RASP 4.0
Configuration to Rockwell PLC for Rapid Link
Generation Change RASP4 to RASP5
Brochures
Rapid Link 5 - brochure
DA-SW-drivesConnect - installation help
DA-SW-USB Driver PC Cable DX-CBL-PC-1M5
DA-SW-Driver DX-CBL-PC-3M0
DA-SW-drivesConnect - Installationshilfe
DA-SW-USB Driver DX-COM-STICK3-KIT
DA-SW-drivesConnect USB Driver DX-COM-PCKIT
DA-SW-drivesConnect
Material handling applications - airports, warehouses and intra-logistics
Catalogues
Product Range Catalog Drives Engineering-EN
Product Range Catalog Drives Engineering
Certification reports
Drawings
eCAD model
Installation instructions
IL034085ZU
10.10 Temperature rise
The panel builder is responsible for the temperature rise
calculation. Eaton will provide heat dissipation data for the
devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the
switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the
switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in
the instruction leaflet (IL) is observed.
Installation videos
Rapid Link 5
Manuals and user guides
MN034004EN
MZ040046_EN
MN040003_EN
mCAD model
ramo5_
rasp5_
Eaton Corporation plc
Eaton House
30 Pembroke Road
Dublin 4, Ireland
Eaton is a registered trademark.
All other trademarks are
© 2023 Eaton. All rights property of their respective
reserved. owners.
/socialmedia
2024年10月6日发(作者:巨清嘉)
Eaton 198773
Eaton Moeller® series Rapid Link - Speed controllers, 4.3 A, 1.5
kW, Sensor input 4, 180/207 V DC, AS-Interface®, S-7.4 for 31
modules, HAN Q4/2, STO (Safe Torque Off)
General specifications
Product NameCatalog Number
Eaton Moeller® series Rapid Link Speed 198773
controller
EAN
4
Product Length/Depth
157 mm
Product Width
220 mm
Certifications
IEC/EN 61800-5-1
RoHS
UL approval
UL 61800-5-1
CE
Product Height
270 mm
Product Weight
3.42 kg
Catalog Notes
can be switched
over from U/f to
(vector) speed
control
Connection of
supply voltage
via adapter
cable on round
or flexible
busbar junction
Diagnostics and
reset on device
and via AS-
Interface
Four fixed
speeds
integrated PTC
thermistor
Features
Parameterization: drivesConnect mobile (App)
Diagnostics and reset on device and via AS-Interface
Parameterization: Keypad
Parameterization: drivesConnect
Parameterization: Fieldbus
Fitted with:
Key switch position OFF/RESET
Key switch position HAND
PC connection
Control unit
Internal DC link
Four fixed speeds
IGBT inverter
Key switch position AUTO
Thermo-click with safe isolation
Two sensor inputs through M12 sockets (max. 150 mA) for quick
stop and interlocked manual operation
Selector switch (Positions: REV - OFF - FWD)
PTC thermistor monitoring
Functions
STO (Safe Torque Off)
For actuation of motors with mechanical brake
Mounting position
Vertical
Shock resistance
15 g, Mechanical, According to IEC/EN 60068-2-27, 11 ms, Half-
sinusoidal shock 11 ms, 1000 shocks per shaft
Vibration
Resistance: 57 Hz, Amplitude transition frequency on
acceleration
Resistance: 10 - 150 Hz, Oscillation frequency
Resistance: According to IEC/EN 60068-2-6
Resistance: 6 Hz, Amplitude 0.15 mm
Degree of protection
IP65
NEMA 12
Electromagnetic compatibility
1st and 2nd environments (according to EN 61800-3)
Overvoltage category
III
Product category
Speed controller
Protocol
ASI
AS-Interface profile cable: S-7.4 for 31 modules
Radio interference class
C1: for conducted emissions only
C2, C3: depending on the motor cable length, the connected
load, and ambient conditions. External radio interference
suppression filters (optional) may be necessary.
Rated impulse withstand voltage (Uimp)
2000 V
System configuration type
Center-point earthed star network (TN-S network)
AC voltage
Phase-earthed AC supply systems are not permitted.
Altitude
Max. 2000 m
Above 1000 m with 1 % performance reduction per 100 m
Ambient operating temperature - min
-10 °C
Ambient operating temperature - max
40 °C
Ambient storage temperature - min
-40 °C
Ambient storage temperature - max
70 °C
Climatic proofing
< 95 %, no condensation
In accordance with IEC/EN 50178
Current limitation
0.4 - 4.3 A, motor, main circuit
Adjustable, motor, main circuit
Delay time
< 10 ms, On-delay
< 10 ms, Off-delay
Efficiency
98 % (η)
Input current ILN at 150% overload
4.1 A
Leakage current at ground IPE - max
3.5 mA
Mains current distortion
120 %
Mains switch-on frequency
Maximum of one time every 60 seconds
Mains voltage - min
380 V
Mains voltage - max
480 V
Mains voltage tolerance
380 - 480 V (-10 %/+10 %, at 50/60 Hz)
Operating mode
Sensorless vector control (SLV)
U/f control
BLDC motors
PM and LSPM motors
Synchronous reluctance motors
Output frequency - min
0 Hz
Output frequency - max
500 Hz
Overload current
At 40 °C
For 60 s every 600 s
Overload current IL at 150% overload
6.5 A
Rated frequency - min
45 Hz
Rated frequency - max
66 Hz
Rated operational power at 380/400 V, 50 Hz, 3-phase
1.5 kW
Rated operational voltage
480 V AC, 3-phase
400 V AC, 3-phase
Resolution
0.1 Hz (Frequency resolution, setpoint value)
Starting current - max
200 %, IH, max. starting current (High Overload), For 2 seconds
every 20 seconds, Power section
Supply frequency
50/60 Hz
Switching frequency
8 kHz, 4 - 32 kHz adjustable, fPWM, Power section, Main circuit
System configuration type
Center-point earthed star network (TN-S network)
AC voltage
Phase-earthed AC supply systems are not permitted.
Communication interface
AS-Interface
Connection
Plug type: HAN Q4/2
Interfaces
Specification: S-7.4 (AS-Interface®)
Number of slave addresses: 31 (AS-Interface®)
Max. total power consumption from AS-Interface® power supply
unit (30 V): 190 mA
Assigned motor power at 460/480 V, 60 Hz, 3-phase
2 HP
Braking current
≤ 0.6 A (max. 6 A for 120 ms), Actuator for
external motor brake
Braking torque
≤ 30 % (I/Ie)
Adjustable to 100 % (I/Ie), DC - Main circuit
Braking voltage
280/207 V DC -15 % / +10 %, Actuator for external motor brake
Rated conditional short-circuit current (Iq)
10 kA
Short-circuit protection (external output circuits)
Type 1 coordination via the power bus' feeder unit, Main circuit
Rated control voltage (Uc)
180/207 V DC (external brake 50/60 Hz)
24 V DC (-15 %/+20 %, external via AS-Interface® plug)
Cable length
C3 ≤ 25 m, maximum motor cable length
C1 ≤ 1 m, maximum motor cable length
C2 ≤ 5 m, maximum motor cable length
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to
normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal
elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be
evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be
evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be
evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be
evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be
evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
Application notes
Connecting drives to generator supplies
Electromagnetic compatibility (EMC)
Generation Change RA-SP to RASP5
Generation change RAMO4 to RAMO5
Generation change from RA-MO to RAMO 4.0
Generation change from RA-SP to RASP 4.0
Configuration to Rockwell PLC for Rapid Link
Generation Change RASP4 to RASP5
Brochures
Rapid Link 5 - brochure
DA-SW-drivesConnect - installation help
DA-SW-USB Driver PC Cable DX-CBL-PC-1M5
DA-SW-Driver DX-CBL-PC-3M0
DA-SW-drivesConnect - Installationshilfe
DA-SW-USB Driver DX-COM-STICK3-KIT
DA-SW-drivesConnect USB Driver DX-COM-PCKIT
DA-SW-drivesConnect
Material handling applications - airports, warehouses and intra-logistics
Catalogues
Product Range Catalog Drives Engineering-EN
Product Range Catalog Drives Engineering
Certification reports
Drawings
eCAD model
Installation instructions
IL034085ZU
10.10 Temperature rise
The panel builder is responsible for the temperature rise
calculation. Eaton will provide heat dissipation data for the
devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the
switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the
switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in
the instruction leaflet (IL) is observed.
Installation videos
Rapid Link 5
Manuals and user guides
MN034004EN
MZ040046_EN
MN040003_EN
mCAD model
ramo5_
rasp5_
Eaton Corporation plc
Eaton House
30 Pembroke Road
Dublin 4, Ireland
Eaton is a registered trademark.
All other trademarks are
© 2023 Eaton. All rights property of their respective
reserved. owners.
/socialmedia