2024年10月6日发(作者:冉听莲)
Eaton 198859
Eaton Moeller® series Rapid Link - Speed controllers, 8.5 A, 4 kW,
Sensor input 4, 400/480 V AC, AS-Interface®, S-7.4 for 31
modules, HAN Q4/2, with manual override switch, with braking
resistance, with fan
General specifications
Product NameCatalog Number
Eaton Moeller® series Rapid Link Speed 198859
controller
EAN
4
Product Length/DepthProduct Height
195 mm270 mm
Product WidthProduct Weight
220 mm3.78 kg
CertificationsCatalog Notes
IEC/EN 61800-5-1
RoHS
3 fixed speeds
UL 61800-5-1
and 1
UL approval
potentiometer
CE
speed
can be switched
over from U/f to
(vector) speed
control
Connection of
supply voltage
via adapter
cable on round
or flexible
busbar junction
Diagnostics and
reset on device
and via AS-
Mains voltage - max
480 V
10.11 Short-circuit rating
Interface
Model Code
RASP5-8404A31-412R101S1
Brochure
integrated PTC
Rapid Link 5 - brochure
thermistor
DA-SW-USB Driver DX-COM-STICK3-KIT
monitoring and
safe isolation
DA-SW-drivesConnect - Installationshilfe
optional: 4
DA-SW-Driver DX-CBL-PC-3M0
sensor inputs
DA-SW-USB Driver PC Cable DX-CBL-PC-1M5
with M12-Y
adapter for
creep speed
DA-SW-drivesConnect - installation help
switchover to
Material handling applications - airports, warehouses and intra-logistics
DA-SW-drivesConnect
Thermoclick with
Is the panel builder's responsibility. The specifications for the
switchgear must be observed.
Rated operational voltage
400 V AC, 3-phase
480 V AC, 3-phase
10.4 Clearances and creepage distances
Meets the product standard's requirements.
Disegni
optional: Faster
Output at quadratic load at rated output voltage - max
stop if external
4 kW
Output voltage - max
500 V
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
Ambient storage temperature - min
-40 °C
Mains voltage - min
380 V
Fitted with:
Selector switch (Positions: REV - OFF - FWD)
Internal DC link
Breaking resistance
IGBT inverter
Manual override switch
Two sensor inputs through M12 sockets (max. 150 mA) for quick
stop and interlocked manual operation
Key switch position AUTO
Braking resistance
Fan
PTC thermistor monitoring
Key switch position HAND
Control unit
PC connection
Key switch position OFF/RESET
Thermo-click with safe isolation
Output frequency - min
24 V fails
Two sensor
inputs through
M12 sockets
(max. 150 mA)
eCAD model
for quick stop
and interlocked
Istruzioni di installazione
manual
operation
with AUTO -
IL034085ZU
mCAD model
OFF/RESET -
rasp5_
HAND key
ramo5_
switches
with selector
switch REV -
OFF - FWD
Note per l'applicazione
Configuration to Rockwell PLC for Rapid Link
Generation Change RA-SP to RASP5
Generation change from RA-MO to RAMO 4.0
Generation Change RASP4 to RASP5
Generation change from RA-SP to RASP 4.0
Generation change RAMO4 to RAMO5
Report di certificazione
0 Hz
Starting current - max
200 %, IH, max. starting current (High Overload), For 2 seconds
every 20 seconds, Power section
Rated conditional short-circuit current (Iq)
10 kA
Ambient operating temperature - max
40 °C
Communication interface
AS-Interface
Assigned motor power at 115/120 V, 60 Hz, 1-phase
5 HP
Output frequency - max
500 Hz
Switching frequency
8 kHz, 4 - 32 kHz adjustable, fPWM, Power section, Main circuit
Features
Parameterization: drivesConnect mobile (App)
Parameterization: drivesConnect
Diagnostics and reset on device and via AS-Interface
Internal and on heat sink, temperature-controlled Fan
Parameterization: Keypad
Parameterization: Fieldbus
Ambient operating temperature - min
-10 °C
Braking current
≤ 0.6 A (max. 6 A for 120 ms), Actuator for
external motor brake
Number of HW-interfaces (serial TTY)
0
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be
evaluated.
Nominal output current I2N
8.5 A
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be
evaluated.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be
evaluated.
Product category
Speed controller
Radio interference class
C2, C3: depending on the motor cable length, the connected
load, and ambient conditions. External radio interference
suppression filters (optional) may be necessary.
C1: for conducted emissions only
Heat dissipation capacity Pdiss
0 W
Rated control voltage (Uc)
24 V DC (-15 %/+20 %, external via AS-Interface® plug)
400/480 V AC (external brake 50/60 Hz)
Assigned motor power at 460/480 V, 60 Hz, 3-phase
5 HP
Number of HW-interfaces (RS-422)
0
Mains current distortion
120 %
Protocol
ASI
AS-Interface profile cable: S-7.4 for 31 modules
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
Overvoltage category
III
Degree of protection
IP65
NEMA 12
Ambient storage temperature - max
70 °C
Rated impulse withstand voltage (Uimp)
2000 V
Connection
Plug type: HAN Q4/2
Overload current
For 60 s every 600 s
At 40 °C
Functions
For actuation of motors with mechanical brake
Brake chopper with braking resistance for dynamic braking
1 potentiometer speed
3 fixed speeds
4-quadrant operation possible
Output at linear load at rated output voltage - max
4 kW
Mains voltage tolerance
380 - 480 V (-10 %/+10 %, at 50/60 Hz)
Leakage current at ground IPE - max
3.5 mA
Converter type
U converter
10.2.2 Corrosion resistance
Meets the product standard's requirements.
Supply frequency
50/60 Hz
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.7 Inscriptions
Meets the product standard's requirements.
Shock resistance
15 g, Mechanical, According to IEC/EN 60068-2-27, 11 ms, Half-
sinusoidal shock 11 ms, 1000 shocks per shaft
Application in domestic and commercial area permitted
Yes
Number of inputs (analog)
0
Number of phases (output)
3
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the
switchgear must be observed.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be
evaluated.
Number of HW-interfaces (RS-485)
1
Number of HW-interfaces (industrial ethernet)
0
Efficiency
98 % (η)
System configuration type
AC voltage
Phase-earthed AC supply systems are not permitted.
Center-point earthed star network (TN-S network)
10.8 Connections for external conductors
Is the panel builder's responsibility.
Switch-on threshold for the braking transistor
765 VDC
Protection
Finger and back-of-hand proof, Protection against direct contact
(BGV A3, VBG4)
Braking voltage
400/480 V AC -15 % / +10 %, Actuator for external motor brake
Application in industrial area permitted
Yes
Climatic proofing
< 95 %, no condensation
In accordance with IEC/EN 50178
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
Overload current IL at 150% overload
12.7 A
Input current ILN at 150% overload
7.8 A
Number of HW-interfaces (RS-232)
0
Number of inputs (digital)
4
Current limitation
Adjustable, motor, main circuit
0.8 - 8.5 A, motor, main circuit
Cable length
C1 ≤ 1 m, maximum motor cable length
C2 ≤ 5 m, maximum motor cable length
C3
≤ 25 m, maximum motor cable length
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be
evaluated.
Mounting position
Vertical
Mains switch-on frequency
Maximum of one time every 60 seconds
10.13 Mechanical function
The device meets the requirements, provided the information in
the instruction leaflet (IL) is observed.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
Heat dissipation per pole, current-dependent Pvid
0 W
Electromagnetic compatibility
1st and 2nd environments (according to EN 61800-3)
Resolution
0.1 Hz (Frequency resolution, setpoint value)
Assigned motor power at 460/480 V, 60 Hz
5 HP
Relative symmetric net voltage tolerance
10 %
Rated operational current (Ie)
8.5 A at 150% overload (at an operating frequency of 8 kHz and
an ambient air temperature of +40 °C)
Number of outputs (analog)
0
Rated operational power at 380/400 V, 50 Hz, 3-phase
4 kW
Number of HW-interfaces (USB)
0
Operating mode
BLDC motors
Synchronous reluctance motors
U/f control
PM and LSPM motors
Sensorless vector control (SLV)
Rated frequency - min
45 Hz
Delay time
< 10 ms, On-delay
< 10 ms, Off-delay
Number of outputs (digital)
0
Power consumption
95 W
10.2.3.2 Verification of resistance of insulating materials to
normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal
elect. effects
Meets the product standard's requirements.
Number of HW-interfaces (other)
1
Rated frequency - max
66 Hz
Vibration
Resistance: 10 - 150 Hz, Oscillation frequency
Resistance: According to IEC/EN 60068-2-6
Resistance: 57 Hz, Amplitude transition frequency on
acceleration
Resistance: 6 Hz, Amplitude 0.15 mm
Short-circuit protection (external output circuits)
Type 1 coordination via the power bus' feeder unit, Main circuit
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
Braking torque
≤ 30 % (I/Ie)
Adjustable to 100 % (I/Ie), DC - Main circuit
Relative symmetric net frequency tolerance
10 %
10.10 Temperature rise
The panel builder is responsible for the temperature rise
calculation. Eaton will provide heat dissipation data for the
devices.
Number of HW-interfaces (parallel)
0
Assigned motor power at 230/240 V, 60 Hz, 1-phase
5 HP
Interfaces
Max. total power consumption from AS-Interface® power supply
unit (30 V): 190 mA
Specification: S-7.4 (AS-Interface®)
Number of slave addresses: 31 (AS-Interface®)
Number of phases (input)
3
Heat dissipation at current/speed
51.6 W at 25% current and 0% speed
53.8 W at 25% current and 50% speed
60.9 W at 50% current and 0% speed
64 W at 50% current and 90% speed
65.4 W at 50% current and 50% speed
85.1 W at 100% current and 0% speed
94 W at 100% current and 50% speed
95.3 W at 100% current and 90% speed
Number of interfaces (PROFINET)
0
Altitude
Max. 2000 m
Above 1000 m with 1 % performance reduction per 100 m
Eaton Corporation plc
Eaton House
30 Pembroke Road
Dublin 4, Ireland
Eaton is a registered trademark.
All other trademarks are
© 2023 Eaton. Tutti i diritti property of their respective
riservati. owners.
/socialmedia
2024年10月6日发(作者:冉听莲)
Eaton 198859
Eaton Moeller® series Rapid Link - Speed controllers, 8.5 A, 4 kW,
Sensor input 4, 400/480 V AC, AS-Interface®, S-7.4 for 31
modules, HAN Q4/2, with manual override switch, with braking
resistance, with fan
General specifications
Product NameCatalog Number
Eaton Moeller® series Rapid Link Speed 198859
controller
EAN
4
Product Length/DepthProduct Height
195 mm270 mm
Product WidthProduct Weight
220 mm3.78 kg
CertificationsCatalog Notes
IEC/EN 61800-5-1
RoHS
3 fixed speeds
UL 61800-5-1
and 1
UL approval
potentiometer
CE
speed
can be switched
over from U/f to
(vector) speed
control
Connection of
supply voltage
via adapter
cable on round
or flexible
busbar junction
Diagnostics and
reset on device
and via AS-
Mains voltage - max
480 V
10.11 Short-circuit rating
Interface
Model Code
RASP5-8404A31-412R101S1
Brochure
integrated PTC
Rapid Link 5 - brochure
thermistor
DA-SW-USB Driver DX-COM-STICK3-KIT
monitoring and
safe isolation
DA-SW-drivesConnect - Installationshilfe
optional: 4
DA-SW-Driver DX-CBL-PC-3M0
sensor inputs
DA-SW-USB Driver PC Cable DX-CBL-PC-1M5
with M12-Y
adapter for
creep speed
DA-SW-drivesConnect - installation help
switchover to
Material handling applications - airports, warehouses and intra-logistics
DA-SW-drivesConnect
Thermoclick with
Is the panel builder's responsibility. The specifications for the
switchgear must be observed.
Rated operational voltage
400 V AC, 3-phase
480 V AC, 3-phase
10.4 Clearances and creepage distances
Meets the product standard's requirements.
Disegni
optional: Faster
Output at quadratic load at rated output voltage - max
stop if external
4 kW
Output voltage - max
500 V
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
Ambient storage temperature - min
-40 °C
Mains voltage - min
380 V
Fitted with:
Selector switch (Positions: REV - OFF - FWD)
Internal DC link
Breaking resistance
IGBT inverter
Manual override switch
Two sensor inputs through M12 sockets (max. 150 mA) for quick
stop and interlocked manual operation
Key switch position AUTO
Braking resistance
Fan
PTC thermistor monitoring
Key switch position HAND
Control unit
PC connection
Key switch position OFF/RESET
Thermo-click with safe isolation
Output frequency - min
24 V fails
Two sensor
inputs through
M12 sockets
(max. 150 mA)
eCAD model
for quick stop
and interlocked
Istruzioni di installazione
manual
operation
with AUTO -
IL034085ZU
mCAD model
OFF/RESET -
rasp5_
HAND key
ramo5_
switches
with selector
switch REV -
OFF - FWD
Note per l'applicazione
Configuration to Rockwell PLC for Rapid Link
Generation Change RA-SP to RASP5
Generation change from RA-MO to RAMO 4.0
Generation Change RASP4 to RASP5
Generation change from RA-SP to RASP 4.0
Generation change RAMO4 to RAMO5
Report di certificazione
0 Hz
Starting current - max
200 %, IH, max. starting current (High Overload), For 2 seconds
every 20 seconds, Power section
Rated conditional short-circuit current (Iq)
10 kA
Ambient operating temperature - max
40 °C
Communication interface
AS-Interface
Assigned motor power at 115/120 V, 60 Hz, 1-phase
5 HP
Output frequency - max
500 Hz
Switching frequency
8 kHz, 4 - 32 kHz adjustable, fPWM, Power section, Main circuit
Features
Parameterization: drivesConnect mobile (App)
Parameterization: drivesConnect
Diagnostics and reset on device and via AS-Interface
Internal and on heat sink, temperature-controlled Fan
Parameterization: Keypad
Parameterization: Fieldbus
Ambient operating temperature - min
-10 °C
Braking current
≤ 0.6 A (max. 6 A for 120 ms), Actuator for
external motor brake
Number of HW-interfaces (serial TTY)
0
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be
evaluated.
Nominal output current I2N
8.5 A
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be
evaluated.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be
evaluated.
Product category
Speed controller
Radio interference class
C2, C3: depending on the motor cable length, the connected
load, and ambient conditions. External radio interference
suppression filters (optional) may be necessary.
C1: for conducted emissions only
Heat dissipation capacity Pdiss
0 W
Rated control voltage (Uc)
24 V DC (-15 %/+20 %, external via AS-Interface® plug)
400/480 V AC (external brake 50/60 Hz)
Assigned motor power at 460/480 V, 60 Hz, 3-phase
5 HP
Number of HW-interfaces (RS-422)
0
Mains current distortion
120 %
Protocol
ASI
AS-Interface profile cable: S-7.4 for 31 modules
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
Overvoltage category
III
Degree of protection
IP65
NEMA 12
Ambient storage temperature - max
70 °C
Rated impulse withstand voltage (Uimp)
2000 V
Connection
Plug type: HAN Q4/2
Overload current
For 60 s every 600 s
At 40 °C
Functions
For actuation of motors with mechanical brake
Brake chopper with braking resistance for dynamic braking
1 potentiometer speed
3 fixed speeds
4-quadrant operation possible
Output at linear load at rated output voltage - max
4 kW
Mains voltage tolerance
380 - 480 V (-10 %/+10 %, at 50/60 Hz)
Leakage current at ground IPE - max
3.5 mA
Converter type
U converter
10.2.2 Corrosion resistance
Meets the product standard's requirements.
Supply frequency
50/60 Hz
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.7 Inscriptions
Meets the product standard's requirements.
Shock resistance
15 g, Mechanical, According to IEC/EN 60068-2-27, 11 ms, Half-
sinusoidal shock 11 ms, 1000 shocks per shaft
Application in domestic and commercial area permitted
Yes
Number of inputs (analog)
0
Number of phases (output)
3
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the
switchgear must be observed.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be
evaluated.
Number of HW-interfaces (RS-485)
1
Number of HW-interfaces (industrial ethernet)
0
Efficiency
98 % (η)
System configuration type
AC voltage
Phase-earthed AC supply systems are not permitted.
Center-point earthed star network (TN-S network)
10.8 Connections for external conductors
Is the panel builder's responsibility.
Switch-on threshold for the braking transistor
765 VDC
Protection
Finger and back-of-hand proof, Protection against direct contact
(BGV A3, VBG4)
Braking voltage
400/480 V AC -15 % / +10 %, Actuator for external motor brake
Application in industrial area permitted
Yes
Climatic proofing
< 95 %, no condensation
In accordance with IEC/EN 50178
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
Overload current IL at 150% overload
12.7 A
Input current ILN at 150% overload
7.8 A
Number of HW-interfaces (RS-232)
0
Number of inputs (digital)
4
Current limitation
Adjustable, motor, main circuit
0.8 - 8.5 A, motor, main circuit
Cable length
C1 ≤ 1 m, maximum motor cable length
C2 ≤ 5 m, maximum motor cable length
C3
≤ 25 m, maximum motor cable length
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be
evaluated.
Mounting position
Vertical
Mains switch-on frequency
Maximum of one time every 60 seconds
10.13 Mechanical function
The device meets the requirements, provided the information in
the instruction leaflet (IL) is observed.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
Heat dissipation per pole, current-dependent Pvid
0 W
Electromagnetic compatibility
1st and 2nd environments (according to EN 61800-3)
Resolution
0.1 Hz (Frequency resolution, setpoint value)
Assigned motor power at 460/480 V, 60 Hz
5 HP
Relative symmetric net voltage tolerance
10 %
Rated operational current (Ie)
8.5 A at 150% overload (at an operating frequency of 8 kHz and
an ambient air temperature of +40 °C)
Number of outputs (analog)
0
Rated operational power at 380/400 V, 50 Hz, 3-phase
4 kW
Number of HW-interfaces (USB)
0
Operating mode
BLDC motors
Synchronous reluctance motors
U/f control
PM and LSPM motors
Sensorless vector control (SLV)
Rated frequency - min
45 Hz
Delay time
< 10 ms, On-delay
< 10 ms, Off-delay
Number of outputs (digital)
0
Power consumption
95 W
10.2.3.2 Verification of resistance of insulating materials to
normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal
elect. effects
Meets the product standard's requirements.
Number of HW-interfaces (other)
1
Rated frequency - max
66 Hz
Vibration
Resistance: 10 - 150 Hz, Oscillation frequency
Resistance: According to IEC/EN 60068-2-6
Resistance: 57 Hz, Amplitude transition frequency on
acceleration
Resistance: 6 Hz, Amplitude 0.15 mm
Short-circuit protection (external output circuits)
Type 1 coordination via the power bus' feeder unit, Main circuit
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
Braking torque
≤ 30 % (I/Ie)
Adjustable to 100 % (I/Ie), DC - Main circuit
Relative symmetric net frequency tolerance
10 %
10.10 Temperature rise
The panel builder is responsible for the temperature rise
calculation. Eaton will provide heat dissipation data for the
devices.
Number of HW-interfaces (parallel)
0
Assigned motor power at 230/240 V, 60 Hz, 1-phase
5 HP
Interfaces
Max. total power consumption from AS-Interface® power supply
unit (30 V): 190 mA
Specification: S-7.4 (AS-Interface®)
Number of slave addresses: 31 (AS-Interface®)
Number of phases (input)
3
Heat dissipation at current/speed
51.6 W at 25% current and 0% speed
53.8 W at 25% current and 50% speed
60.9 W at 50% current and 0% speed
64 W at 50% current and 90% speed
65.4 W at 50% current and 50% speed
85.1 W at 100% current and 0% speed
94 W at 100% current and 50% speed
95.3 W at 100% current and 90% speed
Number of interfaces (PROFINET)
0
Altitude
Max. 2000 m
Above 1000 m with 1 % performance reduction per 100 m
Eaton Corporation plc
Eaton House
30 Pembroke Road
Dublin 4, Ireland
Eaton is a registered trademark.
All other trademarks are
© 2023 Eaton. Tutti i diritti property of their respective
riservati. owners.
/socialmedia