Ophir RF 5100F RF 功率放大器说明书

IT圈 admin 19浏览 0评论

2024年11月6日发(作者:司玥)

1

9

8

1

OWNER’S MANUAL

Model 5100F

RF POWER AMPLIFIER

0.8 – 2.5 GHz, 25 Watts

Ophir RF

5300 Beethoven Street

Los Angeles, CA 90066

USA

OM_5100F 12/12/01

Tel.: (310) 306-5556

FAX: (310) 577-9887

E-mail: *****************

Website:

___________________________________________________

Certification

Ophir RF certifies that this product met its published specifications at the time of

shipment from the factory.

_____________________________________________________________________

Warranty

This Ophir RF product is warranted against defects in material and workmanship for a

period of two (2) years from date of receipt. During the warranty period, Ophir RF, will,

at its option, either repair or replace products that prove to be defective. For warranty

service or repair, this product must be returned to a service facility designated by

Ophir RF.

Limitation of Warranty

The foregoing warranty shall not apply to defects resulting from improper or

inadequate maintenance by Buyer, Buyer-supplied software or interfacing,

unauthorized modification or misuse, operation outside of the environmental

specifications for the product, or improper site preparation or maintenance.

NO OTHER WARRANTY IS EXPRESSED OR IMPLIED. OPHIR RF

SPECIFICALLY DISCLAIMS THE IMPLIED WARRANTIES OF

MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.

Exclusive Remedies

THE REMEDIES PROVIDED HEREIN ARE BUYER’S SOLE AND EXCLUSIVE

REMEDIES. OPHIR RF SHALL NOT BE LIABLE FOR ANY DIRECT,

INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,

WHETHER BASED ON CONTRACT, TORT, OR ANY OTHER LEGAL

THEORY.

_____________________________________________________________________

Assistance

For any assistance, contact your Ophir RF Sales and Service Office.

OM_5100F 12/12/01

Page 1 of 14

_____________________________________________________________________

Safety Information

The following safety notes and symbol are used in this manual and on the equipment.

Familiarize yourself with each and its meaning before operating this equipment.

Caution Caution denotes a hazard. It calls attention to a procedure that, if not

correctly performed or adhered to, would result in damage to, or

destruction of, the equipment. Do not proceed beyond a caution note

until the indicated conditions are fully understood and met.

_____________________________________________________________________

Warning Warning denotes a hazard. It calls attention to a procedure which, if

not correctly performed or adhered to, could result in injury or loss

of life. Do not proceed beyond a warning note until the indicated

conditions are fully understood and met.

_____________________________________________________________________

The instruction documentation symbol. The product is marked with this

symbol when it is necessary for the user to refer to the instructions in the

documentation.

_____________________________________________________________________

General Safety Considerations

This is a safety Class I product provided with a protective earthing

ground incorporated in the AC power cord. The AC power cord

shall only be inserted in a socket outlet provided with a protective

earth contact. Any interruption of the protective conductor, inside

or outside of the equipment, is likely to make the equipment

dangerous. Intentional interruption is prohibited.

_____________________________________________________________________

Warning No operator serviceable parts inside. Refer servicing to qualified

personnel. To prevent electrical shock, do not remove covers.

_____________________________________________________________________

Warning If this equipment is used in a manner not specified by Ophir RF, the

protection provided by the equipment may be impaired.

_____________________________________________________________________

Caution Before switching on this equipment, make sure that the line voltage is

correct and that an External Load has been applied. (Refer to 2.2.3)

OM_5100F 12/12/01

Page 2 of 14

Warning

Contents

Section

Page

I

General Information 5

II

III

IV

Cleaning

V

Return

Repackaging

RMA

OM_5100F 12/12/01

Declaration of Conformity

Scope

Description

Equipment Specifications

Installation

Incoming Inspection

Preparation for Use

Power Requirements

Earthing

Load Requirements

Cable

Connections

Operation

Introduction

Statement Against Unspecified Use

Controls, Indicators, and Connectors

Basic Operating Procedures

Before Turn On

Turn On

Operation

Turn Off

Maintenance

Introduction

Performance Test

Adjustment Procedures

Troubleshooting Procedures

Improper Power Distribution

Low or No RF Output Power

Customer Service 11

Servicing

Material Authorization (RMA) 11

for Shipment 11

Request Form 12

5

5

5

6

7

7

7

7

7

7

7

8

8

8

8

8

8

9

9

9

10

10

10

10

10

10

10

10

11

Page 3 of 14

Figures

Figure 1 Block diagram 13

Figure 2

Table 1 Equipment

OM_5100F 12/12/01

System View

Tables

Specifications 6

14

Page 4 of 14

SECTION I

General Information

1.1 Declaration Of Conformity

DECLARATION OF CE CONFORMITY

Ophir RF Inc., 5300 Beethoven Street, Los Angeles, CA 90066, declares under

sole responsibility that the RF Power Amplifier, Model 5100F, to which this

declaration relates, meets essential health and safety requirements and is in

conformity with ISO 3864. The CE marking has been applied according to the

relevant Safety and CE Directives listed below using the relevant section of the

following EC standards and other normative documents:

EU EMC DIRECTIVE 89/366/EEC - Essential health and safety requirements

relating to electromagnetic compatibility

ENEN55022 Class B

EN50082-1 EC generic immunity requirements, Category A & B

IEC801-2, IEC801-3, IEC801-4

EC Low Voltage Directive 72/23/EEC Essential health and safety

requirements relating to electrical equipment designed for use within certain

violate limits.

EN61010-1 Safety requirements of Test Measurement and Laboratory

Equipment.

1.2 Scope

This owner’s manual contains operating instructions for a model 5100F

amplifier.

1.3 Description

The power amplifier operates in the RF frequency. The input to the power

amplifier is rated at 0 dBm nominal CW signal between the 0.8 – 2.5 GHz

frequency range. The output of the power amplifier is specified at 25 Watts CW

RF signal. Detailed specifications for the power amplifier are given in table 1-1.

OM_5100F 12/12/01

Page 5 of 14

Equipment Specifications

Table 1-1. Specifications @ 25º C

Class of Operation: A/AB

Frequency Range: 0.8 – 2.5 GHz

Output Power @ Saturation: 25 Watts CW Typical

Output Power @ 1 dB Compression: 20 Watts CW minimum

Small Signal Gain: +45 dB minimum

Small Signal Gain Flatness: ± 2.0 dB maximum

Input/Output Impedance: 50 ohms nominal

Input VSWR: 2:1 maximum

Max. RF Input +10 dBm

Operating Temperature Range: 0º C to 50º C

Operating Humidity Range: 95%, Non-condensing

Temp. Protection: Shut down @ 80º C minimum

Cooling system: Internal Forced Air

AC Input: 100 - 240 VAC, 50/60 Hz, 1¯

AC Input Power: 200 Watts maximum

Dimensions: 19" W x 3.5" H x 18" D

Weight: 30 Pounds maximum

Option(s) included:

- Type-N Connectors on Front Panel.

*NOTE – Specifications subject to change without notice

OM_5100F 12/12/01

Page 6 of 14

SECTION II

Installation

2.1 Incoming Inspection

WARNING!

Do not apply power until you have read Sections II and III and you have

performed all specified procedures. If you fail to observe this warning,

damage to the equipment and/or bodily injury may result.

The power amplifier has been mechanically and electrically inspected prior to

shipment. If the equipment has been damaged or if electrical performance is

not within specification, notify the carrier and OPHIR RF immediately.

2.2

Preparation For Use

2.2.1 Power Requirements

The power amplifier requires a power source of 100 – 240 VAC, 50/60

Hz capable of delivering 200 Watts. Turn off the front panel ‘ON/OFF’

switch before connecting the AC power source.

2.2.2 Earthing

Earthing is achieved simultaneously with connection of the AC power

cords to a properly grounded power source.

2.2.3 Load Requirements

The power amplifier requires a load, antenna, or dummy load with a 50-

Ohm nominal impedance.

CAUTION!

Make this external load connection before applying any power to the

equipment.

2.2.4 Cable Connections

The AC power cable connection is made at the rear of the power

amplifier via the receptacle connector. RF connections for Input and

Output are made at the front via Type-N connectors. (Refer to Figure 2)

OM_5100F 12/12/01

Page 7 of 14

SECTION III

Operation

3.1 Introduction

This section describes the operating controls and procedures of the power

amplifier.

3.2 Statement Against Unspecified Use

This amplifier must be used as specified by the manufacturer. Use of this

equipment in any way not specified by the manufacturer may result in bodily

injury and/or damage to the equipment.

3.3 Controls, Indicators, and Connectors

When set to ‘ON’, the ON/OFF switch will light indicating that AC power is

present. The RF INPUT and OUTPUT connections are located on the front of

the power amplifier. Refer to figure 2 and the following discussion for the

location and functional description of all controls, indicators, and connectors.

3.4

Basic Operating Procedures

NOTE!

The operation of the power amplifier is passive; that is, after an External Load

and Input power have been applied, no procedures other than turn off are

required.

3.5

Before Turn On

CAUTION!

Do not obstruct the airflow at the front and rear of the power amplifier. If

you do not verify that this equipment has an unobstructed airflow, you

may cause this equipment to overheat or otherwise impair its operation.

Perform the following preliminary procedures before energizing the equipment:

a. Check that the ON/OFF switch is set to the ‘OFF’ position.

b. At the rear of the RF power amplifier, verify that the AC cord is properly

inserted into the receptacle connector.

c. Verify that 50 ohm loads are connected to the RF Input and Output ports.

3.6. Turn On

Perform the following procedures to energize the equipment:

a. Set the ON/OFF switch to the ‘ON’ position. Verify that the green switch

lamp is lit.

b. Apply RF power.

OM_5100F 12/12/01

Page 8 of 14

CAUTION!

To maintain specified performance and retain certain operating

characteristics, RF input power should not exceed +10 dBm.

3.7. Operation

3.7.1 ON/OFF Switch

In the ‘ON’ position, AC power is supplied to the power amplifier.

3.7.2 ON/OFF Switch Lamp

Lights to indicate the distribution of AC power throughout the power

amplifier.

3.7.3 TEMP. FAULT Indicator

Lights at an internal temperature exceeding 80º C with the amplifier

turning off DC bias voltage to the main amplifiers’ modules. DC bias

voltage will automatically return at temperatures below 75º C.

3.8 Turn Off.

WARNING!

In the event of ANY power failure, whenever possible and practical, it is

advisable to reset the ON/OFF switch on the front panel to the “OFF”

position before you reconnect AC power to the power amplifier. This is to

prevent any possible electrical damage to the amplifier, due to the initial

power surge, once power is restored.

Turn off the RF power amplifier by first lowering or removing the RF Input drive

level and then placing the ON/OFF switch in the ‘OFF’ position.

OM_5100F 12/12/01

Page 9 of 14

SECTION IV

Maintenance

4.1

Introduction

This section describes the performance tests, adjustments and troubleshooting

procedures for the power amplifier.

4.2 Performance Test

The performance test is identical to the operating procedure described in

Section III.

4.3 Adjustment Procedure

There are no operator adjustments applicable for the power amplifier.

4.4 Troubleshooting Procedure

NOTE!

Troubleshooting beyond the level described in this procedure must be

performed at an authorized service facility or the warranty may be voided.

The following troubleshooting procedure is to be used as a guide to help

ascertain whether the equipment is malfunctioning.

4.4.1 Improper Power Distribution

Whenever there appears to be improper power distributed throughout the

amplifier, perform the following steps:

a. Verify the ‘ON/OFF’ switch lamp is illuminated on the front panel.

b. Verify that the internal fans are operating.

c. If neither step A or B above appear to be working, verify the presence

of AC power at the source and also at rear panel connection.

4.4.2 Low or No RF Output Power

Whenever the RF output power of the amplifier and/or the current drawn

from the power supply is low, or the operating temperature has exceeded

80°C, the system may have triggered the thermal protection function.

Perform the following procedure:

a. Verify that the drive level is correct.

b. Check that the ‘TEMP. FAULT’ indicator is not illuminated.

If the above conditions are verified and there is still low or no RF output

power, then contact your nearest authorized Ophir RF Service Center.

4.5. CLEANING

Use a rag with isopropyl alcohol to clean exterior surfaces. Use a vacuum to

remove dust from the screens on the front and rear of the equipment.

OM_5100F 12/12/01

Page 10 of 14

SECTION V

Customer Service

5.1 Servicing

All servicing and repair must be done by an authorized repair and servicing

facility.

5.2 Return Material Authorization (RMA)

5.3

In the unlikely event you experience equipment difficulties that can not be

resolved without opening up the equipment, you will need to obtain

authorization and an RMA number prior to returning the equipment.

NOTE!

It is Ophir RF’s policy not to accept any returned equipment without an

authorized RMA number!

Repackaging for Shipment.

WARNING!

It is always recommended that two people carry this system due to its weight.

Use the original shipping container and packing materials if possible. If these

have been discarded or are not in good condition for reuse, use a heavy-duty

carton capable of providing adequate protection. Whenever the amplifier is

being returned to the manufacturer, attach an identifying tag, indicating the

RMA number, on the outside of the container.

Wrap the equipment in heavy paper or plastic, and use enough shock-

absorbing material (3 to 4-inch layers) around all sides to provide a firm cushion

and to prevent movement within the container. Protect the front and rear

panels with cardboard or foam blocks. Seal the shipping container securely

and mark the container "FRAGILE".

To receive your RMA number, contact our customer service department.

Customer Service

Phone: 310-306-5556

Fax: 310-577-9887

Email: ***************************

You will be required to complete a simple questionnaire prior to receiving your

RMA number. Once you have your RMA number, you are authorized to return

your equipment.

To help you expedite this process, we have included a copy of the form you will

be required to complete prior to receiving your RMA number.

OM_5100F 12/12/01

Page 11 of 14

5300 Beethoven Street, Los Angeles, CA 90066

Tel: (310) 306-5556 • FAX (310) 577-9887 •e-mail:***************************

RMA REQUEST FORM

RMA NUMBER:

CUSTOMER NAME:

RECEIVED

FROM ADDRESS:

(STREET ADDRESS – INCLUDING SUITE OR M/S NUMBER)

(CITY – STATE – ZIP OR COUNTRY CODE) (COUNTRY)

RETURN TO

ADDRESS:

(STREET ADDRESS – INCLUDING SUITE OR M/S NUMBER)

(CITY – STATE – ZIP OR COUNTRY CODE) (COUNTRY)

CONTACT PERSON:

(FIRST AND LAST NAME) (TITLE/RANK)

(TELEPHONE) (FAX)

(E-MAIL)

MODEL NUMBER

REASON FOR RMA:

SERIAL NUMBER

PLEASE FAX THIS FORM TO OPHIR RF, INC.

AT (310) 577-9887 ATTN: CUSTOMER SERVICE

THERE IS A $500 MINIMUM EVALUATION CHARGE FOR ALL NON-WARRANTY

REPAIRS. PURCHASE ORDER TO BE PRESENTED PRIOR TO COMMENCEMENT OF

REPAIRS. FOLLOWING EVALUATION, THE COST OF REPAIRS WILL BE SUBMITTED

FOR YOUR APPROVAL AND PURCHASE ORDER AMENDMENT.

DO NOT SHIP AMPLIFIERS C.O.D. – OPHIR RF WILL NOT ACCEPT ANY C.O.D.

SHIPMENTS. PLEASE CALL US WITH ANY SHIPPING QUESTIONS.

OM_5100F 12/12/01

Page 12 of 14

2024年11月6日发(作者:司玥)

1

9

8

1

OWNER’S MANUAL

Model 5100F

RF POWER AMPLIFIER

0.8 – 2.5 GHz, 25 Watts

Ophir RF

5300 Beethoven Street

Los Angeles, CA 90066

USA

OM_5100F 12/12/01

Tel.: (310) 306-5556

FAX: (310) 577-9887

E-mail: *****************

Website:

___________________________________________________

Certification

Ophir RF certifies that this product met its published specifications at the time of

shipment from the factory.

_____________________________________________________________________

Warranty

This Ophir RF product is warranted against defects in material and workmanship for a

period of two (2) years from date of receipt. During the warranty period, Ophir RF, will,

at its option, either repair or replace products that prove to be defective. For warranty

service or repair, this product must be returned to a service facility designated by

Ophir RF.

Limitation of Warranty

The foregoing warranty shall not apply to defects resulting from improper or

inadequate maintenance by Buyer, Buyer-supplied software or interfacing,

unauthorized modification or misuse, operation outside of the environmental

specifications for the product, or improper site preparation or maintenance.

NO OTHER WARRANTY IS EXPRESSED OR IMPLIED. OPHIR RF

SPECIFICALLY DISCLAIMS THE IMPLIED WARRANTIES OF

MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.

Exclusive Remedies

THE REMEDIES PROVIDED HEREIN ARE BUYER’S SOLE AND EXCLUSIVE

REMEDIES. OPHIR RF SHALL NOT BE LIABLE FOR ANY DIRECT,

INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,

WHETHER BASED ON CONTRACT, TORT, OR ANY OTHER LEGAL

THEORY.

_____________________________________________________________________

Assistance

For any assistance, contact your Ophir RF Sales and Service Office.

OM_5100F 12/12/01

Page 1 of 14

_____________________________________________________________________

Safety Information

The following safety notes and symbol are used in this manual and on the equipment.

Familiarize yourself with each and its meaning before operating this equipment.

Caution Caution denotes a hazard. It calls attention to a procedure that, if not

correctly performed or adhered to, would result in damage to, or

destruction of, the equipment. Do not proceed beyond a caution note

until the indicated conditions are fully understood and met.

_____________________________________________________________________

Warning Warning denotes a hazard. It calls attention to a procedure which, if

not correctly performed or adhered to, could result in injury or loss

of life. Do not proceed beyond a warning note until the indicated

conditions are fully understood and met.

_____________________________________________________________________

The instruction documentation symbol. The product is marked with this

symbol when it is necessary for the user to refer to the instructions in the

documentation.

_____________________________________________________________________

General Safety Considerations

This is a safety Class I product provided with a protective earthing

ground incorporated in the AC power cord. The AC power cord

shall only be inserted in a socket outlet provided with a protective

earth contact. Any interruption of the protective conductor, inside

or outside of the equipment, is likely to make the equipment

dangerous. Intentional interruption is prohibited.

_____________________________________________________________________

Warning No operator serviceable parts inside. Refer servicing to qualified

personnel. To prevent electrical shock, do not remove covers.

_____________________________________________________________________

Warning If this equipment is used in a manner not specified by Ophir RF, the

protection provided by the equipment may be impaired.

_____________________________________________________________________

Caution Before switching on this equipment, make sure that the line voltage is

correct and that an External Load has been applied. (Refer to 2.2.3)

OM_5100F 12/12/01

Page 2 of 14

Warning

Contents

Section

Page

I

General Information 5

II

III

IV

Cleaning

V

Return

Repackaging

RMA

OM_5100F 12/12/01

Declaration of Conformity

Scope

Description

Equipment Specifications

Installation

Incoming Inspection

Preparation for Use

Power Requirements

Earthing

Load Requirements

Cable

Connections

Operation

Introduction

Statement Against Unspecified Use

Controls, Indicators, and Connectors

Basic Operating Procedures

Before Turn On

Turn On

Operation

Turn Off

Maintenance

Introduction

Performance Test

Adjustment Procedures

Troubleshooting Procedures

Improper Power Distribution

Low or No RF Output Power

Customer Service 11

Servicing

Material Authorization (RMA) 11

for Shipment 11

Request Form 12

5

5

5

6

7

7

7

7

7

7

7

8

8

8

8

8

8

9

9

9

10

10

10

10

10

10

10

10

11

Page 3 of 14

Figures

Figure 1 Block diagram 13

Figure 2

Table 1 Equipment

OM_5100F 12/12/01

System View

Tables

Specifications 6

14

Page 4 of 14

SECTION I

General Information

1.1 Declaration Of Conformity

DECLARATION OF CE CONFORMITY

Ophir RF Inc., 5300 Beethoven Street, Los Angeles, CA 90066, declares under

sole responsibility that the RF Power Amplifier, Model 5100F, to which this

declaration relates, meets essential health and safety requirements and is in

conformity with ISO 3864. The CE marking has been applied according to the

relevant Safety and CE Directives listed below using the relevant section of the

following EC standards and other normative documents:

EU EMC DIRECTIVE 89/366/EEC - Essential health and safety requirements

relating to electromagnetic compatibility

ENEN55022 Class B

EN50082-1 EC generic immunity requirements, Category A & B

IEC801-2, IEC801-3, IEC801-4

EC Low Voltage Directive 72/23/EEC Essential health and safety

requirements relating to electrical equipment designed for use within certain

violate limits.

EN61010-1 Safety requirements of Test Measurement and Laboratory

Equipment.

1.2 Scope

This owner’s manual contains operating instructions for a model 5100F

amplifier.

1.3 Description

The power amplifier operates in the RF frequency. The input to the power

amplifier is rated at 0 dBm nominal CW signal between the 0.8 – 2.5 GHz

frequency range. The output of the power amplifier is specified at 25 Watts CW

RF signal. Detailed specifications for the power amplifier are given in table 1-1.

OM_5100F 12/12/01

Page 5 of 14

Equipment Specifications

Table 1-1. Specifications @ 25º C

Class of Operation: A/AB

Frequency Range: 0.8 – 2.5 GHz

Output Power @ Saturation: 25 Watts CW Typical

Output Power @ 1 dB Compression: 20 Watts CW minimum

Small Signal Gain: +45 dB minimum

Small Signal Gain Flatness: ± 2.0 dB maximum

Input/Output Impedance: 50 ohms nominal

Input VSWR: 2:1 maximum

Max. RF Input +10 dBm

Operating Temperature Range: 0º C to 50º C

Operating Humidity Range: 95%, Non-condensing

Temp. Protection: Shut down @ 80º C minimum

Cooling system: Internal Forced Air

AC Input: 100 - 240 VAC, 50/60 Hz, 1¯

AC Input Power: 200 Watts maximum

Dimensions: 19" W x 3.5" H x 18" D

Weight: 30 Pounds maximum

Option(s) included:

- Type-N Connectors on Front Panel.

*NOTE – Specifications subject to change without notice

OM_5100F 12/12/01

Page 6 of 14

SECTION II

Installation

2.1 Incoming Inspection

WARNING!

Do not apply power until you have read Sections II and III and you have

performed all specified procedures. If you fail to observe this warning,

damage to the equipment and/or bodily injury may result.

The power amplifier has been mechanically and electrically inspected prior to

shipment. If the equipment has been damaged or if electrical performance is

not within specification, notify the carrier and OPHIR RF immediately.

2.2

Preparation For Use

2.2.1 Power Requirements

The power amplifier requires a power source of 100 – 240 VAC, 50/60

Hz capable of delivering 200 Watts. Turn off the front panel ‘ON/OFF’

switch before connecting the AC power source.

2.2.2 Earthing

Earthing is achieved simultaneously with connection of the AC power

cords to a properly grounded power source.

2.2.3 Load Requirements

The power amplifier requires a load, antenna, or dummy load with a 50-

Ohm nominal impedance.

CAUTION!

Make this external load connection before applying any power to the

equipment.

2.2.4 Cable Connections

The AC power cable connection is made at the rear of the power

amplifier via the receptacle connector. RF connections for Input and

Output are made at the front via Type-N connectors. (Refer to Figure 2)

OM_5100F 12/12/01

Page 7 of 14

SECTION III

Operation

3.1 Introduction

This section describes the operating controls and procedures of the power

amplifier.

3.2 Statement Against Unspecified Use

This amplifier must be used as specified by the manufacturer. Use of this

equipment in any way not specified by the manufacturer may result in bodily

injury and/or damage to the equipment.

3.3 Controls, Indicators, and Connectors

When set to ‘ON’, the ON/OFF switch will light indicating that AC power is

present. The RF INPUT and OUTPUT connections are located on the front of

the power amplifier. Refer to figure 2 and the following discussion for the

location and functional description of all controls, indicators, and connectors.

3.4

Basic Operating Procedures

NOTE!

The operation of the power amplifier is passive; that is, after an External Load

and Input power have been applied, no procedures other than turn off are

required.

3.5

Before Turn On

CAUTION!

Do not obstruct the airflow at the front and rear of the power amplifier. If

you do not verify that this equipment has an unobstructed airflow, you

may cause this equipment to overheat or otherwise impair its operation.

Perform the following preliminary procedures before energizing the equipment:

a. Check that the ON/OFF switch is set to the ‘OFF’ position.

b. At the rear of the RF power amplifier, verify that the AC cord is properly

inserted into the receptacle connector.

c. Verify that 50 ohm loads are connected to the RF Input and Output ports.

3.6. Turn On

Perform the following procedures to energize the equipment:

a. Set the ON/OFF switch to the ‘ON’ position. Verify that the green switch

lamp is lit.

b. Apply RF power.

OM_5100F 12/12/01

Page 8 of 14

CAUTION!

To maintain specified performance and retain certain operating

characteristics, RF input power should not exceed +10 dBm.

3.7. Operation

3.7.1 ON/OFF Switch

In the ‘ON’ position, AC power is supplied to the power amplifier.

3.7.2 ON/OFF Switch Lamp

Lights to indicate the distribution of AC power throughout the power

amplifier.

3.7.3 TEMP. FAULT Indicator

Lights at an internal temperature exceeding 80º C with the amplifier

turning off DC bias voltage to the main amplifiers’ modules. DC bias

voltage will automatically return at temperatures below 75º C.

3.8 Turn Off.

WARNING!

In the event of ANY power failure, whenever possible and practical, it is

advisable to reset the ON/OFF switch on the front panel to the “OFF”

position before you reconnect AC power to the power amplifier. This is to

prevent any possible electrical damage to the amplifier, due to the initial

power surge, once power is restored.

Turn off the RF power amplifier by first lowering or removing the RF Input drive

level and then placing the ON/OFF switch in the ‘OFF’ position.

OM_5100F 12/12/01

Page 9 of 14

SECTION IV

Maintenance

4.1

Introduction

This section describes the performance tests, adjustments and troubleshooting

procedures for the power amplifier.

4.2 Performance Test

The performance test is identical to the operating procedure described in

Section III.

4.3 Adjustment Procedure

There are no operator adjustments applicable for the power amplifier.

4.4 Troubleshooting Procedure

NOTE!

Troubleshooting beyond the level described in this procedure must be

performed at an authorized service facility or the warranty may be voided.

The following troubleshooting procedure is to be used as a guide to help

ascertain whether the equipment is malfunctioning.

4.4.1 Improper Power Distribution

Whenever there appears to be improper power distributed throughout the

amplifier, perform the following steps:

a. Verify the ‘ON/OFF’ switch lamp is illuminated on the front panel.

b. Verify that the internal fans are operating.

c. If neither step A or B above appear to be working, verify the presence

of AC power at the source and also at rear panel connection.

4.4.2 Low or No RF Output Power

Whenever the RF output power of the amplifier and/or the current drawn

from the power supply is low, or the operating temperature has exceeded

80°C, the system may have triggered the thermal protection function.

Perform the following procedure:

a. Verify that the drive level is correct.

b. Check that the ‘TEMP. FAULT’ indicator is not illuminated.

If the above conditions are verified and there is still low or no RF output

power, then contact your nearest authorized Ophir RF Service Center.

4.5. CLEANING

Use a rag with isopropyl alcohol to clean exterior surfaces. Use a vacuum to

remove dust from the screens on the front and rear of the equipment.

OM_5100F 12/12/01

Page 10 of 14

SECTION V

Customer Service

5.1 Servicing

All servicing and repair must be done by an authorized repair and servicing

facility.

5.2 Return Material Authorization (RMA)

5.3

In the unlikely event you experience equipment difficulties that can not be

resolved without opening up the equipment, you will need to obtain

authorization and an RMA number prior to returning the equipment.

NOTE!

It is Ophir RF’s policy not to accept any returned equipment without an

authorized RMA number!

Repackaging for Shipment.

WARNING!

It is always recommended that two people carry this system due to its weight.

Use the original shipping container and packing materials if possible. If these

have been discarded or are not in good condition for reuse, use a heavy-duty

carton capable of providing adequate protection. Whenever the amplifier is

being returned to the manufacturer, attach an identifying tag, indicating the

RMA number, on the outside of the container.

Wrap the equipment in heavy paper or plastic, and use enough shock-

absorbing material (3 to 4-inch layers) around all sides to provide a firm cushion

and to prevent movement within the container. Protect the front and rear

panels with cardboard or foam blocks. Seal the shipping container securely

and mark the container "FRAGILE".

To receive your RMA number, contact our customer service department.

Customer Service

Phone: 310-306-5556

Fax: 310-577-9887

Email: ***************************

You will be required to complete a simple questionnaire prior to receiving your

RMA number. Once you have your RMA number, you are authorized to return

your equipment.

To help you expedite this process, we have included a copy of the form you will

be required to complete prior to receiving your RMA number.

OM_5100F 12/12/01

Page 11 of 14

5300 Beethoven Street, Los Angeles, CA 90066

Tel: (310) 306-5556 • FAX (310) 577-9887 •e-mail:***************************

RMA REQUEST FORM

RMA NUMBER:

CUSTOMER NAME:

RECEIVED

FROM ADDRESS:

(STREET ADDRESS – INCLUDING SUITE OR M/S NUMBER)

(CITY – STATE – ZIP OR COUNTRY CODE) (COUNTRY)

RETURN TO

ADDRESS:

(STREET ADDRESS – INCLUDING SUITE OR M/S NUMBER)

(CITY – STATE – ZIP OR COUNTRY CODE) (COUNTRY)

CONTACT PERSON:

(FIRST AND LAST NAME) (TITLE/RANK)

(TELEPHONE) (FAX)

(E-MAIL)

MODEL NUMBER

REASON FOR RMA:

SERIAL NUMBER

PLEASE FAX THIS FORM TO OPHIR RF, INC.

AT (310) 577-9887 ATTN: CUSTOMER SERVICE

THERE IS A $500 MINIMUM EVALUATION CHARGE FOR ALL NON-WARRANTY

REPAIRS. PURCHASE ORDER TO BE PRESENTED PRIOR TO COMMENCEMENT OF

REPAIRS. FOLLOWING EVALUATION, THE COST OF REPAIRS WILL BE SUBMITTED

FOR YOUR APPROVAL AND PURCHASE ORDER AMENDMENT.

DO NOT SHIP AMPLIFIERS C.O.D. – OPHIR RF WILL NOT ACCEPT ANY C.O.D.

SHIPMENTS. PLEASE CALL US WITH ANY SHIPPING QUESTIONS.

OM_5100F 12/12/01

Page 12 of 14

发布评论

评论列表 (0)

  1. 暂无评论