MODULAR DC POWER SUPPLY
MODEL 62000B SERIES
Chroma's
Power Supplies offer many unique features for
new 62000B series of Modular DC The
are very cost effective with high power density
Modular DC Power Supplies of 62000B
Burn-in
The
and
power
features
and plating/electrolysis
include a N+1 redundancy,
applications.
high have
low
remote ON/OFF and programmable control via
densities, hot-swappable maintenance, such
be
current
designed
ripple. These instruments
the CAN bus.
power
as
chargers
inverters,
the LCD panels,
for burn-in
DC-DC
applications
converters,
The
devices.
and many
notebook
other types
computers,
of electronic
battery
module
62000B family offers 5 types of
from
Modern
type of six and three position. The six position
10A
with
to
ranging
90A, and
from
offers
1V to
two
150V,
mainframe
current
power
incorporated
power factor correction circuitry is
mainframe
power
in 62000B providing an input
modules
can envelop in up to requirements.
factor above
output.
not
This PFC
0.98
correction
to meet the
circuity
IEC
fourteen
The
paralleled
62000B
operation
can
for 9KW
six power
power
to
sharing
harmonics.
greatly
only reduces
reduce
the
generation
input current draw and
applications.
and
mainframe
CAN bus
to
control
120KW
easily parallel
for
with
bulk
current
up to
power and
monitoring of the power system using an easy
CAN bus
Optional
control
graphic
of input
allow for
Soft
control
Panels
current
and
to use graphical interface.
USBGPIBAPGRS-485EthernetCAN
Modular DC Power Supply
MODEL 62000B SERIES
Key Features :
■ Voltage range: 1 ~ 150V
■ Current range: Up to 2000A (System)
■ Power range up to 1.5KW per module
up to 120KW per system
■ High Power Density
(464 mW / cm
3
= 7.13 W/In
3
)
■ N+1 Redundancy
■ Hot-swappable
■ Ideal for Burn-in & Plating
■ Remote Sense
■ Remote ON / OFF
■ CAN Bus Control
■ DC OK Signal Output
M
o
d
u
l
a
r
D
C
P
o
w
e
r
S
u
p
p
l
y
f
o
r
B
u
r
n
-
i
n
&
P
l
a
t
i
n
g
A
p
p
l
i
c
a
t
i
o
n
s
Equipped with the functionality of N+1 redundancy and hot-swap,
the 62000B Series of modular DC power supplies are most
applicable for 24 hours non-stop applications such as the SMD
products like DC converters, LCD backlight inverters and routers.
plating production lines, as well as product life burn-in test for IT
For continuous operation applications the modular hot-swap
design allows engineers to replace the failure unit on-site without
shutting down the entire system.
The 62000B modular power supplies are capable of providing high power output up to 120KW/2000A
with minimal specification degradation via CSU(Control & Supervisor Unit). Each chassis is designed
to accommodate a maximum of 9KW and include current sharing capability to ensure system stability.
In addition, for convenient control of even large power systems, a CSU is provided to set and display
output and protection circuits via a standard CAN bus communication protocol.
Available Power Ratings
Current Rating
Voltage Rating
15V
30V
60V
80V
150V
Paralleled unit
of mainframe
Power Rating
9KW
540A
300A
150A
108A
60A
1
18KW
1080A
600A
300A
216A
120A
2
27KW
1620A
900A
450A
324A
180A
3
36KW
2160A
1200A
600A
432A
240A
4
45KW
2700A
1500A
750A
540A
300A
5
Note: Contact the factory for more information on customization of high power system ( >2000A).
A620007 CSU Key Features:
■ Stand-alone controller for paralleled 62000B DC power for bulk power
■ Digital encoder knobs and function keys
■ Simultaneous display of output voltage and current
■ Standard Analog programmable interface
■ Standard CAN Bus
■ Optional Ethernet interface
■ User define I/O interface
A620007 Control & Supervisor Unit
Controller Area Network (CAN) is a multicast shared, differential serial bus standard. CAN was specifically designed to be robust
in electromagnetically noisy environments and can utilize a differential balanced line like RS-485. Introduced by Bosch in 1986 for
in-vehicle networks in cars, it is used in myriad applications including factory automation, building automation, aircraft and aerospace
as well as in cars, trucks and buses. CAN bus replaced bulky wiring harnesses with a two-wire differential cable. CAN provides
services at layers 1 and 2 of the OSI model and uses a broadcast method for placing frames on the wire. CAN provides low-speed,
fault-tolerant transmission of 125 Kbps up to 40 meters, which can function over one wire if a short occurs. Transmission without fault
tolerance is provided up to 1 Mbps and 40 meters, and distances up to 1 km are achieved with bit rates of 50 Kbps. Bit rates up to 1
Mbit/s are possible at network lengths below 40m. Decreasing the bit rate allows longer network distances (e.g. 125 kbit/s at 500 m).
Model 62000B Series
11121314
FRONT PANEL
1. OUTPUT ENABLED LED
2. FAULT INDICATOR
3. OUTPUT VOLTAGE READOUT
4. VOLTAGE TRIMMER (1V-100%)
5. OUTPUT CURRENT READOUT
6. CURRENT TRIMMER (1A-100%)
7. OUTPUT ENABLE/DISABLE SWITCH
REAR PANEL
8. CURRENT SHARING CONNECTOR (FOR MAINFRAME)
9. REMOTE SENSE CONNECTOR
10. I/O CONNECTOR (INCLUDES REMOTE ON/OFF, DC OK, AUX POWER)
11. CAN DIP ADDRESS SWITCH
12. CAN BUS COMMUNICATIONS PORT (OPTIONAL)
13. OUTPUT TERMINALS
14. AC INPUT TERMINAL BLOCK
Model A620007
7
16
1
2
34
5
68917181926
FRONT PANEL
1. OVP INDICATOR
2. VOLTAGE READOUT
3. OTP INDICATOR
4. AC-FAULT INDICATOR
5. CURRENT READOUT
6. MODULE ERROR INDICATOR
7. CV MODE INDICATOR
8. CC MODE INDICATOR
9. ON/OFF ENABLE/DISABLE
10. V-SET BUTTON
11. I-SET BUTTON
12. OVP-SET BUTTON
13. I-MAX LIMITED SETTING
14. ROTARY
15. AC ON/OFF SWITCH
REAR PANEL
16. AC INPUT
17. ETHERNET
18. CAN ADDRESS SET
19. DIP SWITCHING FOR
SYSTEM SETTING
INTERFACE INPUT
20. I/O CONTROL
21. I/O CONTROL INTERFACE OUTPUT
22. TERMINAL-RESISTANCE(CAN)
23. CAN BUS to PC
24. CAN BUS to MAINFRAME
25. EXT-V&I SENSE INPUT
26. APG CONTROL
SOFTPANEL
Main Operation MenuProgram Sequence FunctionBasic Control Function for 30 Channels
Type A - Control with CSU : User can control via APG, CAN Bus/ Ethernet, and front panel manual control for paralleled operation.
Front Panel ControlAPG
CAN or Ethernet
PC
CAN Bus
Output
CAN Bus
Parallel Output
DUT
Output
Type B - Control without CSU : User can only control via CAN Bus for paralleled operation.
Note: The SoftPanel can control four mainframes for paralleled operation.
CAN Bus
PC
Output
CAN Bus
Parallel Output
DUT
Output
Type C - Control without CSU or PC : User can only control via remote on/off signal for paralleled operation.
Note 1 : User can NOT adjust the output voltage when parallel the output.
Note 2 : The output voltage will fixed in factory default voltage.
Note 3 : If need to adjust the output voltage, please adjust when stand alone.
Note 4 : Time delay from output enable until output stable: 10s max.
Remote ON/OFF signal → DRY CONTACT〔Closed = enabled ; Open = disable〕
Output
Parallel Output
DUT
Output
M
o
d
e
l
6
2
0
0
0
B
S
e
r
i
e
s
SPECIFICATIONS
Model
Electrical Specifications
Output Ratings
Output Power
Output Voltage
Output Current
Line Regulation
Load Regulation *1
Programming Accuracy
Measurement Accuracy
Output Noise (20MHz)
Voltage Noise (P-P)
Voltage Ripple (rms)
Current Ripple (rms)
Efficiency
Turn on over shoot voltage *2
Transient Response Time *3
AC Input Voltage
Six Position Mainframe
62015B-15-90
1350W
1~15V
1~90A
62015B-30-50
1500W
1~30V
1~50A
62015B-60-25
1500W
1~60V
1~25A
0.1% FS
1% FS
1% FS
1% FS
62015B-80-18
1440W
1~80V
1~18A
62015B-150-10
1500W
1~150V
1~10A
100mV
30mV
0.9A
> 87% @ full load
100mV
30mV
0.5A
200mV200mV
50mV50mV
0.25A0.18A
> 88% @ full load
5% of nominal output
< 5 ms
400mV
100mV
0.1A
All specifications are subject to change without notice. Please visit our website for the most up to date specifications.
Note*1 : For 50% step load variation with remote sense at maximum output voltage
Note*2 : based on rise time of 100ms
Note*3 : Time for the output voltage to recover within 1% of its rated for a load changed of 25%
Note*4 : Six Position Mainframe through CAN
Three Position Mainframe
Input Power Factor
Protection Function
OVPAutomatically shuts down at 115% of set value
Adjustment Range1~16V1~31V1~65V1~83V1~155V
OCPCurrent limit (0 ~ 100%) / OCP Shutdown at 115% of F.S.
OTPAutomatically shuts down if internal limit is reached
I/O Signal
Remote ON/OFF (I/P)Dry contact (closed = enabled), vice versa
AUX Voltage4 ~ 24V / 0.5A at mainframe (by trimmer adjust voltage)
DC OK Signal Type (O/P)Dry contact (closed = enabled) (Error : OVP / OCP / OTP / AC Fault)
Programming Response Time *4 (Typical)
Rise Time (Full Load)For a programmed 5% to 95% step in output voltage : 100ms
Rise Time (No Load)For a programmed 5% to 95% step in output voltage : 100ms
Fall Time (Full Load)For a programmed 95% to 5% step in output voltage : 40ms
Fall Time (No Load)For a programmed 95% to 5% step in output voltage : 5s
Vout SettingCAN Bus send command to DC module receiver : 1s
Measurement V & IUnder CAN command using fetch : 100ms
Delay TimeFor output ON/OFF enable and disable (under CAN command) : 5s(Single Mainframe)
General Specifications
Remote Sensing3V max. line loss compensation
Parallel OperationCurrent Sharing (
±
5%)
Operating Temperature0 ~ 50
℃
Humidity Range0 ~ 90% RH. Non-condensing
Remote InterfaceCAN Bus (optional)
Safety & EMCCE
Mainframe : 175.6 x 443.9 x 466.2 mm / 6.91 x 17.48 x 18.35 inch (62000B-6-1)
Dimension (H x W x D)
Mainframe : 175.6 x 239.9 x 466.2 mm / 6.91 x 9.44 x 18.35 inch (62000B-3-1)
Module : 138.5 x 67.5 x 377.5 mm / 5.45 x 2.66 x 14.86 inch
Mainframe : 14 Kg / 30.8 lbs (62000B-6-1)
Weight
Mainframe : 8 Kg / 17.6 lbs (62000B-3-1)
Module : 4 Kg / 8.8 lbs
187 ~ 250 Vac (3 Phase 4 Wire,
Δ
Connection ) or 323 ~ 437 Vac (3 Phase 5 Wire, Y Connection) /
45 ~ 65 Hz
187 to 250 Vac (single phase) / 45 ~ 65 Hz
> 0.98@ full load
SPECIFICATIONS
A620007 Control & Supervisor Unit
Output voltage setting (V set + Rotary)
Output current limit setting (I set + Rotary)
Over voltage protection setting (OVP_SET) (Default : 115% Vmax.)
Output ON/OFF
OCP selection : CC mode or Shutdown (By Dip switch selection at rear panel)
Max. output current setting (I max )
Output voltage display (7 segment LED)
Output current display (7 segment LED)
Operating mode indicator : CV or CC
Output ON/OFF indicator
Max. output current display (I max button)
CSU : Over voltage protection
CSU : Over temperature protection
AC fault alarm
Power module fault alarm
Setting Item
Measurement Display Item
Alarm Indicator Item
Remote Control Interface
CAN Bus
Ethernet
Analog Programming Interface
(Standard)
Remote Output ON/OFF
Output ON/OFF Indicator
CV or CC mode Indicator
OTP Indicator
System Fault Indicator
I/O Control Interface
I/P Definition
Pin 1 & 2
Pin 3 & 4
Pin 5 & 6
Pin 7~20
O/P Definition
Pin 1 & 2
Pin 3~20
AC Input Voltage
Dimension
Standard
Optional
Setting voltage (A/I) : 0-10Vdc or 0-1 mA of FS (Resolution : 12 bits, Accuracy : 1% FS)
Setting current (A/I) : 0-10Vdc or 0-1 mA of FS (Resolution : 12 bits, Accuracy : 1% FS)
Monitor voltage (A/O) : 0-10V of FS (Resolution : 12 bits, Accuracy : 1% FS)
Monitor current (A/O) : 0-10V of FS (Resolution : 12 bits, Accuracy : 1% FS)
Dry contact
Active High
TTL Level High=CV mode ; TTL Level Low=CC mode
Active High
Active High
I/O : I/P=10 , O/P=10
Temperature sensor for bulk power system rack A (Active : open / default : short)
Temperature sensor for bulk power system rack B (Active : open / default : short)
Emergency stop for bulk power system
Reserved
OVP
Reserved
Single phase 187-253VAC
High(2U) x width(19")
All specifications are subject to change without notice. Please visit our website for the most up to date specifications.
ORDERING INFORMATION
62000B-3-1 : Three Position 62000B Mainframe
62000B-6-1 : Six Position 62000B Mainframe
62015B-15-90 : DC Power Supply Module, 15V/90A/1350W
62015B-30-50 : DC Power Supply Module, 30V/50A/1500W
62015B-60-25 : DC Power Supply Module, 60V/25A/1500W
62015B-80-18 : DC Power Supply Module, 80V/18A/1440W
62015B-150-10 : DC Power Supply Module, 150V/10A/1500W
A620007 : Control & Supervisor Unit
A620008 : CAN Bus Interface for mainframe
A620010 : Rack Mounting Kit for mainframe
A620011 : Ethernet Interface for CSU
A620012 : AD-Link PCI 7841 CAN Bus Card
A620013 : 19" Rack (23U) for 62000B Series
A620014 : 19" Rack (41U) for 62000B Series
A620016 : Rack Mounting Kit for CSU
A620017 : Softpanel for 62000B Series
A620018 : NI USB-8473 high-speed USB to CAN interface
A620019 : USB Interface Control Box for mainframe & CSU
A620020 : GPIB Interface Control Box for mainframe & CSU
*A620021 : APG Interface Control Box for mainframe
*A620022 : RS-485 Interface Control Box mainframe & CSU
*Call for availability
Developed and Manufactured by :
CHROMA ATE INC.
致茂電子股份有限公司
HEADQUARTERS
No. 66, Hwa-Ya 1st Rd.,
Hwa-Ya Technology Park,
Kuei-Shan Hsiang,33383
Taoyuan County, Taiwan
Tel: +886-3-327-9999
Fax: +886-3-327-8898
Distributed by:
JAPAN
CHROMA JAPAN CORP.
NARA Building 11F 2-2-8
Shinyokohama, Kouhokuku,
Yokohama-shi, Kanagawa,
222-0033 Japan
Tel: +81-45-470-2285
Fax: +81-45-470-2287
U.S.A.
CHROMA SYSTEMS
SOLUTIONS, INC.
25612 Commercentre Drive,
Lake Forest, CA 92630-8830
Tel: +1-949-600-6400
Fax: +1-949-600-6401
Toll Free: +1-866-600-6050
E-mail:*******************
EUROPE
CHROMA ATE EUROPE B.V.
Morsestraat 32, 6716 AH Ede,
The Netherlands
Tel: +31-318-648282
Fax: +31-318-648288
E-mail:******************
Worldwide Distribution and Service Network
62000B-E-200908-PDF
CHINA
CHROMA ELECTRONICS
(SHENZHEN) CO., LTD.
8F, No.4, Nanyou Tian An
Industrial Estate, Shenzhen,
China PC: 518052
Tel: +86-755-2664-4598
Fax: +86-755-2641-9620
2024年11月5日发(作者:回河灵)
1
9
8
1
MODULAR DC POWER SUPPLY
MODEL 62000B SERIES
Chroma's
Power Supplies offer many unique features for
new 62000B series of Modular DC The
are very cost effective with high power density
Modular DC Power Supplies of 62000B
Burn-in
The
and
power
features
and plating/electrolysis
include a N+1 redundancy,
applications.
high have
low
remote ON/OFF and programmable control via
densities, hot-swappable maintenance, such
be
current
designed
ripple. These instruments
the CAN bus.
power
as
chargers
inverters,
the LCD panels,
for burn-in
DC-DC
applications
converters,
The
devices.
and many
notebook
other types
computers,
of electronic
battery
module
62000B family offers 5 types of
from
Modern
type of six and three position. The six position
10A
with
to
ranging
90A, and
from
offers
1V to
two
150V,
mainframe
current
power
incorporated
power factor correction circuitry is
mainframe
power
in 62000B providing an input
modules
can envelop in up to requirements.
factor above
output.
not
This PFC
0.98
correction
to meet the
circuity
IEC
fourteen
The
paralleled
62000B
operation
can
for 9KW
six power
power
to
sharing
harmonics.
greatly
only reduces
reduce
the
generation
input current draw and
applications.
and
mainframe
CAN bus
to
control
120KW
easily parallel
for
with
bulk
current
up to
power and
monitoring of the power system using an easy
CAN bus
Optional
control
graphic
of input
allow for
Soft
control
Panels
current
and
to use graphical interface.
USBGPIBAPGRS-485EthernetCAN
Modular DC Power Supply
MODEL 62000B SERIES
Key Features :
■ Voltage range: 1 ~ 150V
■ Current range: Up to 2000A (System)
■ Power range up to 1.5KW per module
up to 120KW per system
■ High Power Density
(464 mW / cm
3
= 7.13 W/In
3
)
■ N+1 Redundancy
■ Hot-swappable
■ Ideal for Burn-in & Plating
■ Remote Sense
■ Remote ON / OFF
■ CAN Bus Control
■ DC OK Signal Output
M
o
d
u
l
a
r
D
C
P
o
w
e
r
S
u
p
p
l
y
f
o
r
B
u
r
n
-
i
n
&
P
l
a
t
i
n
g
A
p
p
l
i
c
a
t
i
o
n
s
Equipped with the functionality of N+1 redundancy and hot-swap,
the 62000B Series of modular DC power supplies are most
applicable for 24 hours non-stop applications such as the SMD
products like DC converters, LCD backlight inverters and routers.
plating production lines, as well as product life burn-in test for IT
For continuous operation applications the modular hot-swap
design allows engineers to replace the failure unit on-site without
shutting down the entire system.
The 62000B modular power supplies are capable of providing high power output up to 120KW/2000A
with minimal specification degradation via CSU(Control & Supervisor Unit). Each chassis is designed
to accommodate a maximum of 9KW and include current sharing capability to ensure system stability.
In addition, for convenient control of even large power systems, a CSU is provided to set and display
output and protection circuits via a standard CAN bus communication protocol.
Available Power Ratings
Current Rating
Voltage Rating
15V
30V
60V
80V
150V
Paralleled unit
of mainframe
Power Rating
9KW
540A
300A
150A
108A
60A
1
18KW
1080A
600A
300A
216A
120A
2
27KW
1620A
900A
450A
324A
180A
3
36KW
2160A
1200A
600A
432A
240A
4
45KW
2700A
1500A
750A
540A
300A
5
Note: Contact the factory for more information on customization of high power system ( >2000A).
A620007 CSU Key Features:
■ Stand-alone controller for paralleled 62000B DC power for bulk power
■ Digital encoder knobs and function keys
■ Simultaneous display of output voltage and current
■ Standard Analog programmable interface
■ Standard CAN Bus
■ Optional Ethernet interface
■ User define I/O interface
A620007 Control & Supervisor Unit
Controller Area Network (CAN) is a multicast shared, differential serial bus standard. CAN was specifically designed to be robust
in electromagnetically noisy environments and can utilize a differential balanced line like RS-485. Introduced by Bosch in 1986 for
in-vehicle networks in cars, it is used in myriad applications including factory automation, building automation, aircraft and aerospace
as well as in cars, trucks and buses. CAN bus replaced bulky wiring harnesses with a two-wire differential cable. CAN provides
services at layers 1 and 2 of the OSI model and uses a broadcast method for placing frames on the wire. CAN provides low-speed,
fault-tolerant transmission of 125 Kbps up to 40 meters, which can function over one wire if a short occurs. Transmission without fault
tolerance is provided up to 1 Mbps and 40 meters, and distances up to 1 km are achieved with bit rates of 50 Kbps. Bit rates up to 1
Mbit/s are possible at network lengths below 40m. Decreasing the bit rate allows longer network distances (e.g. 125 kbit/s at 500 m).
Model 62000B Series
11121314
FRONT PANEL
1. OUTPUT ENABLED LED
2. FAULT INDICATOR
3. OUTPUT VOLTAGE READOUT
4. VOLTAGE TRIMMER (1V-100%)
5. OUTPUT CURRENT READOUT
6. CURRENT TRIMMER (1A-100%)
7. OUTPUT ENABLE/DISABLE SWITCH
REAR PANEL
8. CURRENT SHARING CONNECTOR (FOR MAINFRAME)
9. REMOTE SENSE CONNECTOR
10. I/O CONNECTOR (INCLUDES REMOTE ON/OFF, DC OK, AUX POWER)
11. CAN DIP ADDRESS SWITCH
12. CAN BUS COMMUNICATIONS PORT (OPTIONAL)
13. OUTPUT TERMINALS
14. AC INPUT TERMINAL BLOCK
Model A620007
7
16
1
2
34
5
68917181926
FRONT PANEL
1. OVP INDICATOR
2. VOLTAGE READOUT
3. OTP INDICATOR
4. AC-FAULT INDICATOR
5. CURRENT READOUT
6. MODULE ERROR INDICATOR
7. CV MODE INDICATOR
8. CC MODE INDICATOR
9. ON/OFF ENABLE/DISABLE
10. V-SET BUTTON
11. I-SET BUTTON
12. OVP-SET BUTTON
13. I-MAX LIMITED SETTING
14. ROTARY
15. AC ON/OFF SWITCH
REAR PANEL
16. AC INPUT
17. ETHERNET
18. CAN ADDRESS SET
19. DIP SWITCHING FOR
SYSTEM SETTING
INTERFACE INPUT
20. I/O CONTROL
21. I/O CONTROL INTERFACE OUTPUT
22. TERMINAL-RESISTANCE(CAN)
23. CAN BUS to PC
24. CAN BUS to MAINFRAME
25. EXT-V&I SENSE INPUT
26. APG CONTROL
SOFTPANEL
Main Operation MenuProgram Sequence FunctionBasic Control Function for 30 Channels
Type A - Control with CSU : User can control via APG, CAN Bus/ Ethernet, and front panel manual control for paralleled operation.
Front Panel ControlAPG
CAN or Ethernet
PC
CAN Bus
Output
CAN Bus
Parallel Output
DUT
Output
Type B - Control without CSU : User can only control via CAN Bus for paralleled operation.
Note: The SoftPanel can control four mainframes for paralleled operation.
CAN Bus
PC
Output
CAN Bus
Parallel Output
DUT
Output
Type C - Control without CSU or PC : User can only control via remote on/off signal for paralleled operation.
Note 1 : User can NOT adjust the output voltage when parallel the output.
Note 2 : The output voltage will fixed in factory default voltage.
Note 3 : If need to adjust the output voltage, please adjust when stand alone.
Note 4 : Time delay from output enable until output stable: 10s max.
Remote ON/OFF signal → DRY CONTACT〔Closed = enabled ; Open = disable〕
Output
Parallel Output
DUT
Output
M
o
d
e
l
6
2
0
0
0
B
S
e
r
i
e
s
SPECIFICATIONS
Model
Electrical Specifications
Output Ratings
Output Power
Output Voltage
Output Current
Line Regulation
Load Regulation *1
Programming Accuracy
Measurement Accuracy
Output Noise (20MHz)
Voltage Noise (P-P)
Voltage Ripple (rms)
Current Ripple (rms)
Efficiency
Turn on over shoot voltage *2
Transient Response Time *3
AC Input Voltage
Six Position Mainframe
62015B-15-90
1350W
1~15V
1~90A
62015B-30-50
1500W
1~30V
1~50A
62015B-60-25
1500W
1~60V
1~25A
0.1% FS
1% FS
1% FS
1% FS
62015B-80-18
1440W
1~80V
1~18A
62015B-150-10
1500W
1~150V
1~10A
100mV
30mV
0.9A
> 87% @ full load
100mV
30mV
0.5A
200mV200mV
50mV50mV
0.25A0.18A
> 88% @ full load
5% of nominal output
< 5 ms
400mV
100mV
0.1A
All specifications are subject to change without notice. Please visit our website for the most up to date specifications.
Note*1 : For 50% step load variation with remote sense at maximum output voltage
Note*2 : based on rise time of 100ms
Note*3 : Time for the output voltage to recover within 1% of its rated for a load changed of 25%
Note*4 : Six Position Mainframe through CAN
Three Position Mainframe
Input Power Factor
Protection Function
OVPAutomatically shuts down at 115% of set value
Adjustment Range1~16V1~31V1~65V1~83V1~155V
OCPCurrent limit (0 ~ 100%) / OCP Shutdown at 115% of F.S.
OTPAutomatically shuts down if internal limit is reached
I/O Signal
Remote ON/OFF (I/P)Dry contact (closed = enabled), vice versa
AUX Voltage4 ~ 24V / 0.5A at mainframe (by trimmer adjust voltage)
DC OK Signal Type (O/P)Dry contact (closed = enabled) (Error : OVP / OCP / OTP / AC Fault)
Programming Response Time *4 (Typical)
Rise Time (Full Load)For a programmed 5% to 95% step in output voltage : 100ms
Rise Time (No Load)For a programmed 5% to 95% step in output voltage : 100ms
Fall Time (Full Load)For a programmed 95% to 5% step in output voltage : 40ms
Fall Time (No Load)For a programmed 95% to 5% step in output voltage : 5s
Vout SettingCAN Bus send command to DC module receiver : 1s
Measurement V & IUnder CAN command using fetch : 100ms
Delay TimeFor output ON/OFF enable and disable (under CAN command) : 5s(Single Mainframe)
General Specifications
Remote Sensing3V max. line loss compensation
Parallel OperationCurrent Sharing (
±
5%)
Operating Temperature0 ~ 50
℃
Humidity Range0 ~ 90% RH. Non-condensing
Remote InterfaceCAN Bus (optional)
Safety & EMCCE
Mainframe : 175.6 x 443.9 x 466.2 mm / 6.91 x 17.48 x 18.35 inch (62000B-6-1)
Dimension (H x W x D)
Mainframe : 175.6 x 239.9 x 466.2 mm / 6.91 x 9.44 x 18.35 inch (62000B-3-1)
Module : 138.5 x 67.5 x 377.5 mm / 5.45 x 2.66 x 14.86 inch
Mainframe : 14 Kg / 30.8 lbs (62000B-6-1)
Weight
Mainframe : 8 Kg / 17.6 lbs (62000B-3-1)
Module : 4 Kg / 8.8 lbs
187 ~ 250 Vac (3 Phase 4 Wire,
Δ
Connection ) or 323 ~ 437 Vac (3 Phase 5 Wire, Y Connection) /
45 ~ 65 Hz
187 to 250 Vac (single phase) / 45 ~ 65 Hz
> 0.98@ full load
SPECIFICATIONS
A620007 Control & Supervisor Unit
Output voltage setting (V set + Rotary)
Output current limit setting (I set + Rotary)
Over voltage protection setting (OVP_SET) (Default : 115% Vmax.)
Output ON/OFF
OCP selection : CC mode or Shutdown (By Dip switch selection at rear panel)
Max. output current setting (I max )
Output voltage display (7 segment LED)
Output current display (7 segment LED)
Operating mode indicator : CV or CC
Output ON/OFF indicator
Max. output current display (I max button)
CSU : Over voltage protection
CSU : Over temperature protection
AC fault alarm
Power module fault alarm
Setting Item
Measurement Display Item
Alarm Indicator Item
Remote Control Interface
CAN Bus
Ethernet
Analog Programming Interface
(Standard)
Remote Output ON/OFF
Output ON/OFF Indicator
CV or CC mode Indicator
OTP Indicator
System Fault Indicator
I/O Control Interface
I/P Definition
Pin 1 & 2
Pin 3 & 4
Pin 5 & 6
Pin 7~20
O/P Definition
Pin 1 & 2
Pin 3~20
AC Input Voltage
Dimension
Standard
Optional
Setting voltage (A/I) : 0-10Vdc or 0-1 mA of FS (Resolution : 12 bits, Accuracy : 1% FS)
Setting current (A/I) : 0-10Vdc or 0-1 mA of FS (Resolution : 12 bits, Accuracy : 1% FS)
Monitor voltage (A/O) : 0-10V of FS (Resolution : 12 bits, Accuracy : 1% FS)
Monitor current (A/O) : 0-10V of FS (Resolution : 12 bits, Accuracy : 1% FS)
Dry contact
Active High
TTL Level High=CV mode ; TTL Level Low=CC mode
Active High
Active High
I/O : I/P=10 , O/P=10
Temperature sensor for bulk power system rack A (Active : open / default : short)
Temperature sensor for bulk power system rack B (Active : open / default : short)
Emergency stop for bulk power system
Reserved
OVP
Reserved
Single phase 187-253VAC
High(2U) x width(19")
All specifications are subject to change without notice. Please visit our website for the most up to date specifications.
ORDERING INFORMATION
62000B-3-1 : Three Position 62000B Mainframe
62000B-6-1 : Six Position 62000B Mainframe
62015B-15-90 : DC Power Supply Module, 15V/90A/1350W
62015B-30-50 : DC Power Supply Module, 30V/50A/1500W
62015B-60-25 : DC Power Supply Module, 60V/25A/1500W
62015B-80-18 : DC Power Supply Module, 80V/18A/1440W
62015B-150-10 : DC Power Supply Module, 150V/10A/1500W
A620007 : Control & Supervisor Unit
A620008 : CAN Bus Interface for mainframe
A620010 : Rack Mounting Kit for mainframe
A620011 : Ethernet Interface for CSU
A620012 : AD-Link PCI 7841 CAN Bus Card
A620013 : 19" Rack (23U) for 62000B Series
A620014 : 19" Rack (41U) for 62000B Series
A620016 : Rack Mounting Kit for CSU
A620017 : Softpanel for 62000B Series
A620018 : NI USB-8473 high-speed USB to CAN interface
A620019 : USB Interface Control Box for mainframe & CSU
A620020 : GPIB Interface Control Box for mainframe & CSU
*A620021 : APG Interface Control Box for mainframe
*A620022 : RS-485 Interface Control Box mainframe & CSU
*Call for availability
Developed and Manufactured by :
CHROMA ATE INC.
致茂電子股份有限公司
HEADQUARTERS
No. 66, Hwa-Ya 1st Rd.,
Hwa-Ya Technology Park,
Kuei-Shan Hsiang,33383
Taoyuan County, Taiwan
Tel: +886-3-327-9999
Fax: +886-3-327-8898
Distributed by:
JAPAN
CHROMA JAPAN CORP.
NARA Building 11F 2-2-8
Shinyokohama, Kouhokuku,
Yokohama-shi, Kanagawa,
222-0033 Japan
Tel: +81-45-470-2285
Fax: +81-45-470-2287
U.S.A.
CHROMA SYSTEMS
SOLUTIONS, INC.
25612 Commercentre Drive,
Lake Forest, CA 92630-8830
Tel: +1-949-600-6400
Fax: +1-949-600-6401
Toll Free: +1-866-600-6050
E-mail:*******************
EUROPE
CHROMA ATE EUROPE B.V.
Morsestraat 32, 6716 AH Ede,
The Netherlands
Tel: +31-318-648282
Fax: +31-318-648288
E-mail:******************
Worldwide Distribution and Service Network
62000B-E-200908-PDF
CHINA
CHROMA ELECTRONICS
(SHENZHEN) CO., LTD.
8F, No.4, Nanyou Tian An
Industrial Estate, Shenzhen,
China PC: 518052
Tel: +86-755-2664-4598
Fax: +86-755-2641-9620