2024年7月31日发(作者:仆凌春)
ROUND CEILING DIFFUSERS
SPUN STEEL CONSTRUCTION • ADJUSTABLE
HORIZONTAL DISCHARGE PATTERN
MODEL: RNR
E= OUTSIDE DIAMETER
CEILING OPENING = NOM. + 1/2" (13)
D= NOMINAL DUCT DIAMETER
D-1/8" (3)
1 1/4" (32)
A (DOWN POSITION)
B (UP POSITION)
DESCRIPTION:
al: Corrosion-resistant steel.
Nailor RNR series round ceiling diffusers feature
three concentric cones in all sizes to offer a balanced
appearance where different sizes are used in the same
area.
diffusers deliver the air in a true 360°radial
horizontal pattern and provide excellent performance
in variable air volume systems.
4.A spring clip arrangement permits quick, easy
installation and removal of the inner cone assembly.
rge settings are easily field set by sliding the
inner cone assembly up or down. The core is securely
retained by a spring loaded friction arrangement.
able horizontal discharge settings allow the
diffusers to accommodate different flow conditions.
Position A (cones down) provides maximum capacity
at minimum NC levels while position B (cones up)
provides higher induction and more air movement.
ed for both heating and cooling applications.
optional round opposed blade damper is
screwdriver-operated through the face of the unit.
rd finish is AW appliance white.
Dimensional Data
Imperial Units (inches)
Listed
Size
6
8
10
12
14
16
18
20
24
A
1 3/4
2 1/8
2 7/8
3 1/8
3 3/8
4
4 3/4
5 7/8
7 3/4
B
1 1/8
1 1/2
2 1/8
2 3/8
2 5/8
3 1/4
3 7/8
4 7/8
6 5/8
E
11 5/8
14 3/8
17 15/16
21 5/8
25 1/4
29
33 1/2
37 1/4
43 7/8
Metric Units (mm)
A
44
54
73
79
86
102
121
149
197
B
29
38
54
60
67
83
98
124
168
E
295
365
456
549
641
737
851
946
1114
OPTIONS:
K
K
K
Finish
SCSafety chain
GKFoam gasket
EQEarthquake tabs
SPSpecial. Specify __________ .
K
SCHEDULE TYPE:
PROJECT:
ENGINEER:
CONTRACTOR:
DATE
Dimensions are in inches (mm).
B SERIESSUPERSEDESDRAWINGNO.
8 - 30 - 05RNR19 - 9 - 00RRNR-1
ROUND CEILING DIFFUSER
SPUN STEEL CONSTRUCTION • ADJUSTABLE
HORIZONTALTO VERTICAL DISCHARGE PATTERN
MODEL: RNRA1
E= OUTSIDE DIAMETER
F= CEILING OPENING
D= NOMINAL DUCT DIAMETER
D-1/8" (3)
1 1/4" (32)
H
A (DOWN POSITION)
B (UP POSITION)
DESCRIPTION:
al: Corrosion-resistant steel.
Nailor RNRA1 round ceiling diffuser
features three concentric cones in all sizes to
offer a balanced appearance where different
sizes are used in the same area.
ed for both heating and cooling
applications. The air discharge pattern is fully
adjustable between horizontal and vertical. In
the fully open (down) setting, capacity is
maximized and throw is horizontal. In the fully
closed (up) setting, air projects vertically down
from the diffuser.
diffusers deliver the air in a true 360°
radial that provides excellent performance in
variable air volume systems.
rge settings are easily field set by
sliding the inner cone assembly up or down.
The core is securely retained by a spring
loaded friction arrangement.
able discharge settings allow the
diffusers to accommodate different flow
conditions.
7.A spring clip arrangement permits quick, easy
installation and removal of the inner cone
assembly.
optional round opposed blade damper is
screwdriver-operated through the face of the
unit.
ed for exposed duct or hard ceiling
applications.
rd finish is AW appliance white.
Dimensional Data
Imperial Units
(inches)
Listed
Size
6
8
10
12
14
16
A
1 3/4
2
2 1/2
3 1/4
3 3/4
4
B
3/4
1
1 1/4
1 3/4
1 3/4
2
E
14 1/8
18 3/4
22 7/8
27 3/8
32
36 1/4
F
12
16
20
24
28
32
H
7/8
1 1/4
1 1/2
1 7/8
1 7/8
2 1/8
A
44
51
64
83
95
102
Metric Units
(mm)
B
19
25
32
44
44
51
E
359
476
581
695
813
921
F
305
406
508
610
711
813
H
22
32
38
48
48
54
OPTIONS:
❑
❑
❑
❑
SCSafety chain
GKFoam gasket
EQEarthquake tabs
SPSpecial. Specify __________ .
Dimensions are in inches (mm).
DATEB SERIESSUPERSEDESDRAWINGNO.
Finish
SCHEDULE TYPE:
PROJECT:
ENGINEER:
CONTRACTOR:
5 - 22 - 08RNR4 - 14 - 08RNRA1
ARCHITECTURAL CEILING DIFFUSERS
ROUND PLAQUE • STEEL
ADJUSTABLE HORIZONTALTO VERTICAL DISCHARGE
MODEL: RUNI
E = OUTSIDE DIAMETER
F = CEILING OPENING
D = NOMINAL DUCT DIAMETER
D - 1/8" (3)
1 1/4" (32)
UP POSITION
(VERTICAL)
H
C
MIDDLE POSITION/FLUSH
(HORIZONTAL)
G = PLAQUE DIAMETER
B
A
DOWN POSITION
(HORIZONTAL)
Dimensional Data
Imperial Units
(inches)
Listed
Size
6
8
10
12
14
16
A
1 3/4
2
2 1/4
2 3/4
3
3 3/8
BCEF
12
16
20
24
28
32
G
9
12
15
18
21
24
H
7/8
1 1/4
1 1/2
1 7/8
1 7/8
2 1/8
A
44
51
57
70
76
86
B
6
13
17
24
25
25
Metric Units
(mm)
C
19
25
30
43
44
51
E
359
476
581
695
813
921
F
305
406
508
610
711
813
G
229
305
381
457
533
610
H
22
32
38
48
48
54
1/43/414 1/8
1/2118 3/4
11/161 3/1622 3/4
15/161 11/1627 3/8
11 3/432
1236 1/4
DESCRIPTION:
al: Corrosion-resistant steel outer cone and bracketry.
Aluminum face.
Nailor RUNI, round ceiling diffusers have been especially
designed to provide the appearance required for architectural
excellence as well as high engineering performance. The
smooth heavy duty face plaque is 1/8
"
(0.125) thick aluminum
for strength and lightness. These diffusers are suitable for
both architectural ceilings and exposed duct applications.
ed for both heating and cooling applications. The air
discharge pattern is fully adjustable between horizontal and
vertical. In the fully open (down) setting, capacity is
maximized and throw is horizontal. In the fully closed (up)
setting, air projects vertically down from the diffuser.
diffusers deliver the air in a true 360
O
radial horizontal
pattern and provide excellent performance in variable air
volume systems.
5.A spring clip arrangement permits quick, easy installation and
removal of the inner cone assembly.
rge setting is simply adjusted by sliding the inner face
plaque assembly up or down. The core is securely retained by
a spring loaded friction arrangement. There are no screws to
reposition.
ed for both heating and cooling applications.
optional duct mounted round opposed blade damper is
screwdriver-operated.
rd finish is AW appliance white.
OPTIONS:
❑SC
❑GK
❑EQT
Safety chain
Foam gasket
Earthquake tabs
Special. Specify __________.
Finish:
❑SP
SCHEDULE TYPE
PROJECT
ENGINEER
CONTRACTOR
DATE
Dimensions are in inches (mm).
B SERIESSUPERSEDESDRAWINGNO.
1 - 21 - 10UNI9 - 14 - 09RUNI-1
ROUND DOWNBLAST DIFFUSER
STEEL •HEAVY DUTY •ADJUSTABLE
VERTICAL TO HORIZONTAL DISCHARGE PATTERN
MODEL: RDB
C = OUTSIDE DIAMETER
MIN. CEILING OPENING = NOM. + 2" (51)
D = NOMINAL DUCT DIAMETER
D - 1/8" (3)
B
3/4" (19)
A
Face View
Dimensional Data
Listed
Size
D
8
10
12
14
16
18
20
24
Imperial Units (inches)
A
11 11/16
14
16 1/4
18 5/8
20 7/8
23 1/4
25 1/2
30 3/16
B
2 1/4
2 9/16
3
3 3/8
4
4 1/2
5 7/16
6 1/2
C
14 3/8
17 15/16
21 5/8
25 1/4
29
33 1/2
37 1/4
43 7/8
Metric Units (mm)
A
297
356
413
473
530
591
648
767
B
57
65
76
86
102
114
138
165
C
365
456
549
641
737
851
946
1114
DESCRIPTION:
al: Heavy gauge corrosion resistant steel.
Nailor RDB heavy duty round downblast ceiling
diffusers have been designed for industrial and
commercial applications. Unique contemporary design
features a "Fibonacci spiral" adjustable aperture.
ally suitable for theaters, auditoriums, factories,
warehouses, convention halls, coliseums, shopping
malls and other applications where ceilings are high and
conditions variable.
discharge pattern can be adjusted from full
horizontal to full vertical. At the full vertical setting, the
diffuser forces approximately 75% of the air in a long
downward projection. This results in effective spot
cooling or heating from high mounting locations.
SCHEDULE TYPE:
PROJECT:
ENGINEER:
CONTRACTOR:
DATE
5. Uniform 360°discharge pattern in the horizontal mode
with excellent performance in VAV applications.
operator can be adjustable with a pole.
optional round opposed blade damper is screwdriver
operated and adjusted through the aperture or by
removing the inner core of the diffuser.
rd finish is AW Appliance White.
OPTIONS:
❑
❑
❑
GKFoam gasket
EQEarthquake Tabs
SPSpecial. Specify __________ .
Finish:
Dimensions are in inches (mm).
B SERIESSUPERSEDESDRAWINGNO.
1 - 9 - 04RBD12 - 8 - 03RDB-1
ROUND CEILING DIFFUSERS
SPUN ALUMINUM CONSTRUCTION • ADJUSTABLE
HORIZONTAL DISCHARGE PATTERN
MODEL: ARNR
E= OUTSIDE DIAMETER
CEILING OPENING = NOM. + 1/2" (13)
D= NOMINAL DUCT DIAMETER
D-1/8" (3)
1 1/4" (32)
A (DOWN POSITION)
B (UP POSITION)
DESCRIPTION:
al: Aluminum with corrosion-resistant steel neck
bracketry.
Nailor ARNR series round ceiling diffusers feature
three concentric cones in all sizes to offer a balanced
appearance where different sizes are used in the same
area.
diffusers deliver the air in a true 360°radial
horizontal pattern and provide excellent performance
in variable air volume systems.
4.A spring clip arrangement permits quick, easy
installation and removal of the inner cone assembly.
rge settings are easily field set by sliding the
inner cone assembly up or down. The core is securely
retained by a spring loaded friction arrangement.
able horizontal discharge settings allow the
diffusers to accommodate different flow conditions.
Position A (cones down) provides maximum capacity
at minimum NC levels while position B (cones up)
provides higher induction and more air movement.
ed for both heating and cooling applications.
optional round opposed blade damper is
screwdriver-operated through the face of the unit.
rd finish is AW appliance white.
Dimensional Data
Imperial Units (inches)
Listed
Size
6
8
10
12
14
16
A
1 3/4
2 1/8
2 7/8
3 1/8
3 3/8
4
B
1 1/8
1 1/2
2 1/8
2 3/8
2 5/8
3 1/4
E
11 5/8
14 3/8
17 15/16
21 5/8
25 1/4
29
Metric Units (mm)
A
44
54
73
79
86
102
B
29
38
54
60
67
83
E
295
365
456
549
641
737
OPTIONS:
K
K
K
Finish
SCSafety chain
GKFoam gasket
EQEarthquake tabs
SPSpecial. Specify __________ .
K
SCHEDULE TYPE:
PROJECT:
ENGINEER:
CONTRACTOR:
DATE
Dimensions are in inches (mm).
B SERIESSUPERSEDESDRAWINGNO.
10 - 24 - 05RNRNEWARNR-1
ROUND CEILING DIFFUSER
SPUN ALUMINUM CONSTRUCTION • ADJUSTABLE
HORIZONTALTO VERTICAL DISCHARGE PATTERN
MODEL: ARNRA1
E= OUTSIDE DIAMETER
F= CEILING OPENING
D= NOMINAL DUCT DIAMETER
D-1/8" (3)
1 1/4" (32)
H
A (DOWN POSITION)
B (UP POSITION)
DESCRIPTION:
al: Aluminum construction with
corrosion-resistant steel neck bracketry.
Nailor ARNRA1 round ceiling diffuser
features three concentric cones in all sizes to
offer a balanced appearance where different
sizes are used in the same area.
ed for both heating and cooling
applications. The air discharge pattern is fully
adjustable between horizontal and vertical. In
the fully open (down) setting, capacity is
maximized and throw is horizontal. In the fully
closed (up) setting, air projects vertically down
from the diffuser.
diffusers deliver the air in a true 360°
radial that provides excellent performance in
variable air volume systems.
rge settings are easily field set by
sliding the inner cone assembly up or down.
The core is securely retained by a spring
loaded friction arrangement.
able discharge settings allow the
diffusers to accommodate different flow
conditions.
7.A spring clip arrangement permits quick, easy
installation and removal of the inner cone
assembly.
optional round opposed blade damper is
screwdriver-operated through the face of the
unit.
ed for exposed duct or hard ceiling
applications.
rd finish is AW appliance white.
Dimensional Data
Imperial Units
(inches)
Listed
Size
6
8
10
12
14
16
A
1 3/4
2
2 1/2
3 1/4
3 3/4
4
B
3/4
1
1 1/4
1 3/4
1 3/4
2
E
14 1/8
18 3/4
22 7/8
27 3/8
32
36 1/4
F
12
16
20
24
28
32
H
7/8
1 1/4
1 1/2
1 7/8
1 7/8
2 1/8
A
44
51
64
83
95
102
Metric Units
(mm)
B
19
25
32
44
44
51
E
359
476
581
695
813
921
F
305
406
508
610
711
813
H
22
32
38
48
48
54
OPTIONS:
❑
❑
❑
❑
SCSafety chain
GKFoam gasket
EQEarthquake tabs
SPSpecial. Specify __________ .
Dimensions are in inches (mm).
DATEB SERIESSUPERSEDESDRAWINGNO.
Finish
SCHEDULE TYPE:
PROJECT:
ENGINEER:
CONTRACTOR:
7 - 20 - 09RNRNEWARNRA1
ARCHITECTURAL CEILING DIFFUSERS
ROUND PLAQUE • ALUMINUM
ADJUSTABLE HORIZONTALTO VERTICAL DISCHARGE
MODEL: ARUNI
E = OUTSIDE DIAMETER
F = CEILING OPENING
D = NOMINAL DUCT DIAMETER
D - 1/8" (3)
1 1/4" (32)
UP POSITION
(VERTICAL)
H
C
MIDDLE POSITION/FLUSH
(HORIZONTAL)
G = PLAQUE DIAMETER
B
A
DOWN POSITION
(HORIZONTAL)
Dimensional Data
Imperial Units
(inches)
Listed
Size
6
8
10
12
14
16
A
1 3/4
2
2 1/4
2 3/4
3
3 3/8
BCEF
12
16
20
24
28
32
G
9
12
15
18
21
24
H
7/8
1 1/4
1 1/2
1 7/8
1 7/8
2 1/8
A
44
51
57
70
76
86
B
6
13
17
24
25
25
Metric Units
(mm)
C
19
25
30
43
44
51
E
359
476
581
695
813
921
F
305
406
508
610
711
813
G
229
305
381
457
533
610
H
22
32
38
48
48
54
1/43/414 1/8
1/2118 3/4
11/161 3/1622 3/4
15/161 11/1627 3/8
11 3/432
1236 1/4
DESCRIPTION:
al: Aluminum outer cone with corrosion-resistant steel
neck bracketry. Aluminum face.
Nailor ARUNI, round ceiling diffusers have been especially
designed to provide the appearance required for architectural
excellence as well as high engineering performance. The
smooth heavy duty face plaque is 1/8
"
(0.125) thick aluminum
for strength and lightness. These diffusers are suitable for both
architectural ceilings and exposed duct applications.
ed for both heating and cooling applications. The air
discharge pattern is fully adjustable between horizontal and
vertical. In the fully open (down) setting, capacity is
maximized and throw is horizontal. In the fully closed (up)
setting, air projects vertically down from the diffuser.
diffusers deliver the air in a true 360
O
radial horizontal
pattern and provide excellent performance in variable air
volume systems.
5.A spring clip arrangement permits quick, easy installation and
removal of the inner cone assembly.
rge setting is simply adjusted by sliding the inner face
plaque assembly up or down. The core is securely retained by
a spring loaded friction arrangement. There are no screws to
reposition.
ed for both heating and cooling applications.
optional duct mounted round opposed blade damper is
screwdriver-operated.
rd finish is AW appliance white.
OPTIONS:
❑SC
❑GK
❑EQT
Safety chain
Foam gasket
Earthquake tabs
Special. Specify __________.
Finish:
❑SP
SCHEDULE TYPE
PROJECT
ENGINEER
CONTRACTOR
DATE
Dimensions are in inches (mm).
B SERIESSUPERSEDESDRAWINGNO.
1 - 21 - 10UNI9 - 14 - 09ARUNI-1
ROUND CEILING DIFFUSERS
SPUN ALUMINUM CONSTRUCTION
MODELS: 6300 AND 6300R
DIA. CEILING OPENING = NOMINAL + 1/4" (6)
DUCT = NOMINAL SIZE (FITS INSIDE COLLAR)
A
3/4" (19)
GASKET
3/4" (19)
C
D
Dimensional Data
Imperial Units
(inches)
Listed
Size
6
8
10
12
14
16
18
20
24
A
6 1/8
8 1/8
10 1/8
12 1/8
14 1/8
16 1/8
18 1/8
20 1/8
24 1/8
C
3/4
1
1 1/4
1 3/8
1 9/16
1 3/4
1 15/16
2 1/8
2 1/2
D
12 1/8
15 1/2
18 7/8
22 1/4
25 5/8
29
32 3/8
35 3/4
42 1/2
Metric Units
(mm)
A
156
206
257
308
358
410
460
511
613
C
19
25
32
35
40
44
49
54
64
D
308
394
479
565
651
737
822
908
1080
Notes:
1/4" (6) oversize duct fits outside collar, if desired.
A = Inside diameter of diffuser neck.
C = Projection of diffuser outer cone below ceiling.
D = Overall diameter of diffuser.
DESCRIPTION:
al: Spun aluminum construction.
Nailor 6300 Series Round Ceiling Diffusers are available
in a comprehensive range of sizes with a capacity ranging
from 50 to 5000 cfm (24 – 2360 l/s). They are suitable for
both cooling and heating applications. They offer the same
balanced appearance where different sizes are used in the
same zone. They feature a 360 degree air diffusion pattern
and provide excellent performance in Variable Air Volume
Systems.
ed for both heating and cooling applications.
ent for variable air volume applications.
rd finish: AW Appliance White.
Model 6300 – Two Position Adjustment
Model 6300is fixed in either an "UP" or a "DOWN"
position through a system of clips to stationary positions.
The core is easily adjusted. An optional round opposed
blade damper is screwdriver-operated through the face of
the unit. The Model 6300has a 2-position core to guide
vertical or horizontal projection of the air.
Model 6300R – Continuous Rotary Adjustment
Model 6300Rprovides 3/4" (19) adjustability through
utilization of a threaded mechanism. The "UP" position of
the core provides vertical throw and the "DOWN" position
provides horizontal throw. The core is easily adjusted. An
optional round opposed blade damper is screwdriver-
operated through the face of the unit. The Model 6300R
has a fully adjustable core to guide vertical or horizontal
projection of the air.
ACCESSORIES (OPTIONAL):
❑
ALAluminum finish.
❑
4275Radial Opposed Blade Damper (round).
❑
EGREqualizing Grid.
❑
SCSafety Chain.
❑
SPSpecial finish.
SCHEDULE TYPE:
PROJECT:
ENGINEER:
CONTRACTOR:
Dimensions are in inches (mm).
DATEB SERIESSUPERSEDESDRAWINGNO.
11 - 5 - 0763001 - 3 - 01R6300-1
2024年7月31日发(作者:仆凌春)
ROUND CEILING DIFFUSERS
SPUN STEEL CONSTRUCTION • ADJUSTABLE
HORIZONTAL DISCHARGE PATTERN
MODEL: RNR
E= OUTSIDE DIAMETER
CEILING OPENING = NOM. + 1/2" (13)
D= NOMINAL DUCT DIAMETER
D-1/8" (3)
1 1/4" (32)
A (DOWN POSITION)
B (UP POSITION)
DESCRIPTION:
al: Corrosion-resistant steel.
Nailor RNR series round ceiling diffusers feature
three concentric cones in all sizes to offer a balanced
appearance where different sizes are used in the same
area.
diffusers deliver the air in a true 360°radial
horizontal pattern and provide excellent performance
in variable air volume systems.
4.A spring clip arrangement permits quick, easy
installation and removal of the inner cone assembly.
rge settings are easily field set by sliding the
inner cone assembly up or down. The core is securely
retained by a spring loaded friction arrangement.
able horizontal discharge settings allow the
diffusers to accommodate different flow conditions.
Position A (cones down) provides maximum capacity
at minimum NC levels while position B (cones up)
provides higher induction and more air movement.
ed for both heating and cooling applications.
optional round opposed blade damper is
screwdriver-operated through the face of the unit.
rd finish is AW appliance white.
Dimensional Data
Imperial Units (inches)
Listed
Size
6
8
10
12
14
16
18
20
24
A
1 3/4
2 1/8
2 7/8
3 1/8
3 3/8
4
4 3/4
5 7/8
7 3/4
B
1 1/8
1 1/2
2 1/8
2 3/8
2 5/8
3 1/4
3 7/8
4 7/8
6 5/8
E
11 5/8
14 3/8
17 15/16
21 5/8
25 1/4
29
33 1/2
37 1/4
43 7/8
Metric Units (mm)
A
44
54
73
79
86
102
121
149
197
B
29
38
54
60
67
83
98
124
168
E
295
365
456
549
641
737
851
946
1114
OPTIONS:
K
K
K
Finish
SCSafety chain
GKFoam gasket
EQEarthquake tabs
SPSpecial. Specify __________ .
K
SCHEDULE TYPE:
PROJECT:
ENGINEER:
CONTRACTOR:
DATE
Dimensions are in inches (mm).
B SERIESSUPERSEDESDRAWINGNO.
8 - 30 - 05RNR19 - 9 - 00RRNR-1
ROUND CEILING DIFFUSER
SPUN STEEL CONSTRUCTION • ADJUSTABLE
HORIZONTALTO VERTICAL DISCHARGE PATTERN
MODEL: RNRA1
E= OUTSIDE DIAMETER
F= CEILING OPENING
D= NOMINAL DUCT DIAMETER
D-1/8" (3)
1 1/4" (32)
H
A (DOWN POSITION)
B (UP POSITION)
DESCRIPTION:
al: Corrosion-resistant steel.
Nailor RNRA1 round ceiling diffuser
features three concentric cones in all sizes to
offer a balanced appearance where different
sizes are used in the same area.
ed for both heating and cooling
applications. The air discharge pattern is fully
adjustable between horizontal and vertical. In
the fully open (down) setting, capacity is
maximized and throw is horizontal. In the fully
closed (up) setting, air projects vertically down
from the diffuser.
diffusers deliver the air in a true 360°
radial that provides excellent performance in
variable air volume systems.
rge settings are easily field set by
sliding the inner cone assembly up or down.
The core is securely retained by a spring
loaded friction arrangement.
able discharge settings allow the
diffusers to accommodate different flow
conditions.
7.A spring clip arrangement permits quick, easy
installation and removal of the inner cone
assembly.
optional round opposed blade damper is
screwdriver-operated through the face of the
unit.
ed for exposed duct or hard ceiling
applications.
rd finish is AW appliance white.
Dimensional Data
Imperial Units
(inches)
Listed
Size
6
8
10
12
14
16
A
1 3/4
2
2 1/2
3 1/4
3 3/4
4
B
3/4
1
1 1/4
1 3/4
1 3/4
2
E
14 1/8
18 3/4
22 7/8
27 3/8
32
36 1/4
F
12
16
20
24
28
32
H
7/8
1 1/4
1 1/2
1 7/8
1 7/8
2 1/8
A
44
51
64
83
95
102
Metric Units
(mm)
B
19
25
32
44
44
51
E
359
476
581
695
813
921
F
305
406
508
610
711
813
H
22
32
38
48
48
54
OPTIONS:
❑
❑
❑
❑
SCSafety chain
GKFoam gasket
EQEarthquake tabs
SPSpecial. Specify __________ .
Dimensions are in inches (mm).
DATEB SERIESSUPERSEDESDRAWINGNO.
Finish
SCHEDULE TYPE:
PROJECT:
ENGINEER:
CONTRACTOR:
5 - 22 - 08RNR4 - 14 - 08RNRA1
ARCHITECTURAL CEILING DIFFUSERS
ROUND PLAQUE • STEEL
ADJUSTABLE HORIZONTALTO VERTICAL DISCHARGE
MODEL: RUNI
E = OUTSIDE DIAMETER
F = CEILING OPENING
D = NOMINAL DUCT DIAMETER
D - 1/8" (3)
1 1/4" (32)
UP POSITION
(VERTICAL)
H
C
MIDDLE POSITION/FLUSH
(HORIZONTAL)
G = PLAQUE DIAMETER
B
A
DOWN POSITION
(HORIZONTAL)
Dimensional Data
Imperial Units
(inches)
Listed
Size
6
8
10
12
14
16
A
1 3/4
2
2 1/4
2 3/4
3
3 3/8
BCEF
12
16
20
24
28
32
G
9
12
15
18
21
24
H
7/8
1 1/4
1 1/2
1 7/8
1 7/8
2 1/8
A
44
51
57
70
76
86
B
6
13
17
24
25
25
Metric Units
(mm)
C
19
25
30
43
44
51
E
359
476
581
695
813
921
F
305
406
508
610
711
813
G
229
305
381
457
533
610
H
22
32
38
48
48
54
1/43/414 1/8
1/2118 3/4
11/161 3/1622 3/4
15/161 11/1627 3/8
11 3/432
1236 1/4
DESCRIPTION:
al: Corrosion-resistant steel outer cone and bracketry.
Aluminum face.
Nailor RUNI, round ceiling diffusers have been especially
designed to provide the appearance required for architectural
excellence as well as high engineering performance. The
smooth heavy duty face plaque is 1/8
"
(0.125) thick aluminum
for strength and lightness. These diffusers are suitable for
both architectural ceilings and exposed duct applications.
ed for both heating and cooling applications. The air
discharge pattern is fully adjustable between horizontal and
vertical. In the fully open (down) setting, capacity is
maximized and throw is horizontal. In the fully closed (up)
setting, air projects vertically down from the diffuser.
diffusers deliver the air in a true 360
O
radial horizontal
pattern and provide excellent performance in variable air
volume systems.
5.A spring clip arrangement permits quick, easy installation and
removal of the inner cone assembly.
rge setting is simply adjusted by sliding the inner face
plaque assembly up or down. The core is securely retained by
a spring loaded friction arrangement. There are no screws to
reposition.
ed for both heating and cooling applications.
optional duct mounted round opposed blade damper is
screwdriver-operated.
rd finish is AW appliance white.
OPTIONS:
❑SC
❑GK
❑EQT
Safety chain
Foam gasket
Earthquake tabs
Special. Specify __________.
Finish:
❑SP
SCHEDULE TYPE
PROJECT
ENGINEER
CONTRACTOR
DATE
Dimensions are in inches (mm).
B SERIESSUPERSEDESDRAWINGNO.
1 - 21 - 10UNI9 - 14 - 09RUNI-1
ROUND DOWNBLAST DIFFUSER
STEEL •HEAVY DUTY •ADJUSTABLE
VERTICAL TO HORIZONTAL DISCHARGE PATTERN
MODEL: RDB
C = OUTSIDE DIAMETER
MIN. CEILING OPENING = NOM. + 2" (51)
D = NOMINAL DUCT DIAMETER
D - 1/8" (3)
B
3/4" (19)
A
Face View
Dimensional Data
Listed
Size
D
8
10
12
14
16
18
20
24
Imperial Units (inches)
A
11 11/16
14
16 1/4
18 5/8
20 7/8
23 1/4
25 1/2
30 3/16
B
2 1/4
2 9/16
3
3 3/8
4
4 1/2
5 7/16
6 1/2
C
14 3/8
17 15/16
21 5/8
25 1/4
29
33 1/2
37 1/4
43 7/8
Metric Units (mm)
A
297
356
413
473
530
591
648
767
B
57
65
76
86
102
114
138
165
C
365
456
549
641
737
851
946
1114
DESCRIPTION:
al: Heavy gauge corrosion resistant steel.
Nailor RDB heavy duty round downblast ceiling
diffusers have been designed for industrial and
commercial applications. Unique contemporary design
features a "Fibonacci spiral" adjustable aperture.
ally suitable for theaters, auditoriums, factories,
warehouses, convention halls, coliseums, shopping
malls and other applications where ceilings are high and
conditions variable.
discharge pattern can be adjusted from full
horizontal to full vertical. At the full vertical setting, the
diffuser forces approximately 75% of the air in a long
downward projection. This results in effective spot
cooling or heating from high mounting locations.
SCHEDULE TYPE:
PROJECT:
ENGINEER:
CONTRACTOR:
DATE
5. Uniform 360°discharge pattern in the horizontal mode
with excellent performance in VAV applications.
operator can be adjustable with a pole.
optional round opposed blade damper is screwdriver
operated and adjusted through the aperture or by
removing the inner core of the diffuser.
rd finish is AW Appliance White.
OPTIONS:
❑
❑
❑
GKFoam gasket
EQEarthquake Tabs
SPSpecial. Specify __________ .
Finish:
Dimensions are in inches (mm).
B SERIESSUPERSEDESDRAWINGNO.
1 - 9 - 04RBD12 - 8 - 03RDB-1
ROUND CEILING DIFFUSERS
SPUN ALUMINUM CONSTRUCTION • ADJUSTABLE
HORIZONTAL DISCHARGE PATTERN
MODEL: ARNR
E= OUTSIDE DIAMETER
CEILING OPENING = NOM. + 1/2" (13)
D= NOMINAL DUCT DIAMETER
D-1/8" (3)
1 1/4" (32)
A (DOWN POSITION)
B (UP POSITION)
DESCRIPTION:
al: Aluminum with corrosion-resistant steel neck
bracketry.
Nailor ARNR series round ceiling diffusers feature
three concentric cones in all sizes to offer a balanced
appearance where different sizes are used in the same
area.
diffusers deliver the air in a true 360°radial
horizontal pattern and provide excellent performance
in variable air volume systems.
4.A spring clip arrangement permits quick, easy
installation and removal of the inner cone assembly.
rge settings are easily field set by sliding the
inner cone assembly up or down. The core is securely
retained by a spring loaded friction arrangement.
able horizontal discharge settings allow the
diffusers to accommodate different flow conditions.
Position A (cones down) provides maximum capacity
at minimum NC levels while position B (cones up)
provides higher induction and more air movement.
ed for both heating and cooling applications.
optional round opposed blade damper is
screwdriver-operated through the face of the unit.
rd finish is AW appliance white.
Dimensional Data
Imperial Units (inches)
Listed
Size
6
8
10
12
14
16
A
1 3/4
2 1/8
2 7/8
3 1/8
3 3/8
4
B
1 1/8
1 1/2
2 1/8
2 3/8
2 5/8
3 1/4
E
11 5/8
14 3/8
17 15/16
21 5/8
25 1/4
29
Metric Units (mm)
A
44
54
73
79
86
102
B
29
38
54
60
67
83
E
295
365
456
549
641
737
OPTIONS:
K
K
K
Finish
SCSafety chain
GKFoam gasket
EQEarthquake tabs
SPSpecial. Specify __________ .
K
SCHEDULE TYPE:
PROJECT:
ENGINEER:
CONTRACTOR:
DATE
Dimensions are in inches (mm).
B SERIESSUPERSEDESDRAWINGNO.
10 - 24 - 05RNRNEWARNR-1
ROUND CEILING DIFFUSER
SPUN ALUMINUM CONSTRUCTION • ADJUSTABLE
HORIZONTALTO VERTICAL DISCHARGE PATTERN
MODEL: ARNRA1
E= OUTSIDE DIAMETER
F= CEILING OPENING
D= NOMINAL DUCT DIAMETER
D-1/8" (3)
1 1/4" (32)
H
A (DOWN POSITION)
B (UP POSITION)
DESCRIPTION:
al: Aluminum construction with
corrosion-resistant steel neck bracketry.
Nailor ARNRA1 round ceiling diffuser
features three concentric cones in all sizes to
offer a balanced appearance where different
sizes are used in the same area.
ed for both heating and cooling
applications. The air discharge pattern is fully
adjustable between horizontal and vertical. In
the fully open (down) setting, capacity is
maximized and throw is horizontal. In the fully
closed (up) setting, air projects vertically down
from the diffuser.
diffusers deliver the air in a true 360°
radial that provides excellent performance in
variable air volume systems.
rge settings are easily field set by
sliding the inner cone assembly up or down.
The core is securely retained by a spring
loaded friction arrangement.
able discharge settings allow the
diffusers to accommodate different flow
conditions.
7.A spring clip arrangement permits quick, easy
installation and removal of the inner cone
assembly.
optional round opposed blade damper is
screwdriver-operated through the face of the
unit.
ed for exposed duct or hard ceiling
applications.
rd finish is AW appliance white.
Dimensional Data
Imperial Units
(inches)
Listed
Size
6
8
10
12
14
16
A
1 3/4
2
2 1/2
3 1/4
3 3/4
4
B
3/4
1
1 1/4
1 3/4
1 3/4
2
E
14 1/8
18 3/4
22 7/8
27 3/8
32
36 1/4
F
12
16
20
24
28
32
H
7/8
1 1/4
1 1/2
1 7/8
1 7/8
2 1/8
A
44
51
64
83
95
102
Metric Units
(mm)
B
19
25
32
44
44
51
E
359
476
581
695
813
921
F
305
406
508
610
711
813
H
22
32
38
48
48
54
OPTIONS:
❑
❑
❑
❑
SCSafety chain
GKFoam gasket
EQEarthquake tabs
SPSpecial. Specify __________ .
Dimensions are in inches (mm).
DATEB SERIESSUPERSEDESDRAWINGNO.
Finish
SCHEDULE TYPE:
PROJECT:
ENGINEER:
CONTRACTOR:
7 - 20 - 09RNRNEWARNRA1
ARCHITECTURAL CEILING DIFFUSERS
ROUND PLAQUE • ALUMINUM
ADJUSTABLE HORIZONTALTO VERTICAL DISCHARGE
MODEL: ARUNI
E = OUTSIDE DIAMETER
F = CEILING OPENING
D = NOMINAL DUCT DIAMETER
D - 1/8" (3)
1 1/4" (32)
UP POSITION
(VERTICAL)
H
C
MIDDLE POSITION/FLUSH
(HORIZONTAL)
G = PLAQUE DIAMETER
B
A
DOWN POSITION
(HORIZONTAL)
Dimensional Data
Imperial Units
(inches)
Listed
Size
6
8
10
12
14
16
A
1 3/4
2
2 1/4
2 3/4
3
3 3/8
BCEF
12
16
20
24
28
32
G
9
12
15
18
21
24
H
7/8
1 1/4
1 1/2
1 7/8
1 7/8
2 1/8
A
44
51
57
70
76
86
B
6
13
17
24
25
25
Metric Units
(mm)
C
19
25
30
43
44
51
E
359
476
581
695
813
921
F
305
406
508
610
711
813
G
229
305
381
457
533
610
H
22
32
38
48
48
54
1/43/414 1/8
1/2118 3/4
11/161 3/1622 3/4
15/161 11/1627 3/8
11 3/432
1236 1/4
DESCRIPTION:
al: Aluminum outer cone with corrosion-resistant steel
neck bracketry. Aluminum face.
Nailor ARUNI, round ceiling diffusers have been especially
designed to provide the appearance required for architectural
excellence as well as high engineering performance. The
smooth heavy duty face plaque is 1/8
"
(0.125) thick aluminum
for strength and lightness. These diffusers are suitable for both
architectural ceilings and exposed duct applications.
ed for both heating and cooling applications. The air
discharge pattern is fully adjustable between horizontal and
vertical. In the fully open (down) setting, capacity is
maximized and throw is horizontal. In the fully closed (up)
setting, air projects vertically down from the diffuser.
diffusers deliver the air in a true 360
O
radial horizontal
pattern and provide excellent performance in variable air
volume systems.
5.A spring clip arrangement permits quick, easy installation and
removal of the inner cone assembly.
rge setting is simply adjusted by sliding the inner face
plaque assembly up or down. The core is securely retained by
a spring loaded friction arrangement. There are no screws to
reposition.
ed for both heating and cooling applications.
optional duct mounted round opposed blade damper is
screwdriver-operated.
rd finish is AW appliance white.
OPTIONS:
❑SC
❑GK
❑EQT
Safety chain
Foam gasket
Earthquake tabs
Special. Specify __________.
Finish:
❑SP
SCHEDULE TYPE
PROJECT
ENGINEER
CONTRACTOR
DATE
Dimensions are in inches (mm).
B SERIESSUPERSEDESDRAWINGNO.
1 - 21 - 10UNI9 - 14 - 09ARUNI-1
ROUND CEILING DIFFUSERS
SPUN ALUMINUM CONSTRUCTION
MODELS: 6300 AND 6300R
DIA. CEILING OPENING = NOMINAL + 1/4" (6)
DUCT = NOMINAL SIZE (FITS INSIDE COLLAR)
A
3/4" (19)
GASKET
3/4" (19)
C
D
Dimensional Data
Imperial Units
(inches)
Listed
Size
6
8
10
12
14
16
18
20
24
A
6 1/8
8 1/8
10 1/8
12 1/8
14 1/8
16 1/8
18 1/8
20 1/8
24 1/8
C
3/4
1
1 1/4
1 3/8
1 9/16
1 3/4
1 15/16
2 1/8
2 1/2
D
12 1/8
15 1/2
18 7/8
22 1/4
25 5/8
29
32 3/8
35 3/4
42 1/2
Metric Units
(mm)
A
156
206
257
308
358
410
460
511
613
C
19
25
32
35
40
44
49
54
64
D
308
394
479
565
651
737
822
908
1080
Notes:
1/4" (6) oversize duct fits outside collar, if desired.
A = Inside diameter of diffuser neck.
C = Projection of diffuser outer cone below ceiling.
D = Overall diameter of diffuser.
DESCRIPTION:
al: Spun aluminum construction.
Nailor 6300 Series Round Ceiling Diffusers are available
in a comprehensive range of sizes with a capacity ranging
from 50 to 5000 cfm (24 – 2360 l/s). They are suitable for
both cooling and heating applications. They offer the same
balanced appearance where different sizes are used in the
same zone. They feature a 360 degree air diffusion pattern
and provide excellent performance in Variable Air Volume
Systems.
ed for both heating and cooling applications.
ent for variable air volume applications.
rd finish: AW Appliance White.
Model 6300 – Two Position Adjustment
Model 6300is fixed in either an "UP" or a "DOWN"
position through a system of clips to stationary positions.
The core is easily adjusted. An optional round opposed
blade damper is screwdriver-operated through the face of
the unit. The Model 6300has a 2-position core to guide
vertical or horizontal projection of the air.
Model 6300R – Continuous Rotary Adjustment
Model 6300Rprovides 3/4" (19) adjustability through
utilization of a threaded mechanism. The "UP" position of
the core provides vertical throw and the "DOWN" position
provides horizontal throw. The core is easily adjusted. An
optional round opposed blade damper is screwdriver-
operated through the face of the unit. The Model 6300R
has a fully adjustable core to guide vertical or horizontal
projection of the air.
ACCESSORIES (OPTIONAL):
❑
ALAluminum finish.
❑
4275Radial Opposed Blade Damper (round).
❑
EGREqualizing Grid.
❑
SCSafety Chain.
❑
SPSpecial finish.
SCHEDULE TYPE:
PROJECT:
ENGINEER:
CONTRACTOR:
Dimensions are in inches (mm).
DATEB SERIESSUPERSEDESDRAWINGNO.
11 - 5 - 0763001 - 3 - 01R6300-1