最新消息: USBMI致力于为网友们分享Windows、安卓、IOS等主流手机系统相关的资讯以及评测、同时提供相关教程、应用、软件下载等服务。

(中文版)ANSI ESD-S20.20-2007

IT圈 admin 51浏览 0评论

2024年8月26日发(作者:司空仙仪)

ANSI/ESD-S20.20-2007

ANSI/ESD-S20.20-1999

之修订版

建立一个

静电放电控制方案

电气和

电子零件,装置和设备

(不包括电动引爆装置)的保护

静电放电协会

7900 Turin Road, Bldg 3, Ste 2,

Rome, NY 13440‑ 2069

美国国家标准

2007年3月1日批准

ii

ESD Association Standards Committee

Standards Interpretation Bulletin

June 19, 2008

The ESD Association Standards Committee is issuing this interpretation bulletin regarding

ANSI/ESD S20.20-2007. This bulletin modifies the requirements specified in Table 3 EPA

Control Items (Garments). Table 3 should now be modified to disregard the two garment types;

“Groundable Static Control Garment” and “Groundable Static Control Garment System”, along

with their Test Methods and Requirements.

Additionally, the “Static Control Garment” Required Limit should be: 1 x 10

5

ohms to 1 x 10

11

ohms, per ANSI/ESD STM2.1-1997.

These changes are necessary because the referenced document, ANSI/ESD STM2.1, has been

brought back to a Work in Progress (WIP) status and therefore these two garment types

(mentioned above) are also brought back to WIP status.

Reference Information

Table 3. EPA ESD Control Items

Technical

Requirement

Product Qualification

Test Method

Static Control Garment

(ANSI/ESD STM2.1)

Groundable Static

Control Garment

(ANSI/ESD STM2.1)

Groundable Static

Control Garment

System

(ANSI/ESD STM2.1)

Required

2

Limit(s)

< 1 x 10

11

ohms

1

ESD Control

Item

Compliance Verification

Test Method

ESD TR53

Garments Section

ESD TR53

Garments Section

Required

Limit(s)

< 1 x 10

11

ohms

< 1 x 10

9

ohms

< 1 x 10

9

ohms

Garments

< 3.5 x 10

7

7

ohms

ESD TR53

Garments Section

< 3.5 x 10

7

7

ohms s

JohnKinnear

Working Group Chairman

Tim Jarrett

Standards Chairman

ESD Association Standards Committee

Standards Change Notification

June 14, 2007

This notification reports on two typos in ANSI/ESD S20.20-2007, Table 2 Personnel Grounding

Requirement. These corrections have been made to the Standard and are highlighted below for

your reference.

Previous Information

Table 2. Personnel Grounding Requirement

Personnel

Grounding

Technical

Requirement

Wrist Strap System

2

Product Qualification

Test Method

ANSI/ESD S1.1

(Section 5.10)

Required Limit(s)

0.8 x 10

6

to

1.2 x 10

6

ohms

1

Compliance Verification

Test Method

ESD TR53

Wrist Strap Section

Required Limit(s)

< 3.5 x 10

7

ohms

Current Information

Table 2. Personnel Grounding Requirement

Personnel

Grounding

Technical

Requirement

Wrist Strap System

2

Product Qualification

Test Method

ANSI/ESD S1.1

(Section 5.11)

Required Limit(s)

< 3.5 x 10

7

ohms

1

Compliance Verification

Test Method

ESD TR53

Wrist Strap Section

Required Limit(s)

< 3.5 x 10

7

ohms

John Kinnear

Working Group Chairman

Tim Jarrett

Standards Chairman

Comments can be sent to the ESD Association by one of the following methods:

Email: info@

Fax: 315-339-6793

美国国家标准学会(ANSI)/静电放电(ESD)协会标准 ANSI/ESD S20.20-2007

静电放电协会标准

建立一个静电放电控制方案

电气和电子零件,装置和设备

(

不包括电动引爆装置

)

的保护

静电放电协会2007年2月11日批准

iii

美国国家标准学会(ANSI)/静电放电(ESD)协会标准 ANSI/ESD S20.20-2007

提醒

静电放电协会(ESDA)之标准和出版物是为了公共利益,即消除制造商与买家之间的误

解,为产品的交流与改进提供方便,以及协助客户选择和获得他所特别需要的产品。

这些标准和出版物的存在,无论在那个方面,都不应妨碍本协会的任何会员或非会员

从事生产和销售并不符合这些标准和出版物的产品。同样,这些标准是由静电放电协

会所出版的事实,并不能妨碍非会员,无论是在国内还是国外,自愿地使用这些档。

遵循美国国家标准局的专利政策,静电放电协会采纳被推荐的标准和出版物。静电放

电协会标准之解释。就可能与特定的产品或制造商相关联的标准的解释,是涉及到具

体公司的关系重大的事情,不可能由任何人替代静电放电协会来做。静电放电协会主

席可以就标准中的技术语言或条款,作出仅限于说明性或澄清性的评论,但不能涉及

特定的产品和制造商。没有任何人被授权,以静电放电协会的名义来评论静电放电协

会之标准。

免责声明

出版者:

静电放电协会之标准和出版物的内容,以“照这样不作修改”的形式获得批准,静电放

电协会对相关内容,既不作专门陈述或保证,也不作表述或暗示。静电放电协会放弃

所有的抗议和保证,包括但并不局限于,商业化保证,特定目的和使用的合理性,标

题和其它非侵权行为。

免除担保:静电放电协会之标准和出版物,在它们被批准的时候,被认为是技术上可

靠的。它们不是用来替代所讨论之产品的商家或用户的自己的判断,而且,静电放电

协会不会,因这些标准和出版物,而对任何具体的制造商的产品的功能,承担任何担

保。因此,静电放电协会明确地拒绝,因使用,应用,或依赖于这些标准和出版物中

所包含信息,所导致的损害的任何责任。

静电放电协会之责任限制:静电放电协会,及它的会员,工作人员,雇员或其它代理

人员,都不对直接或间接地使用或误用静电放电标准或出版物所导致的损坏负责,即

使标准中提到了应用的可能性。这是适用于所有的各种损坏的综合性责任限制,包括

但并不局限于,资料,收入或利润的损失,财产的损失或损坏,以及第三方的索赔。

Electrostatic Discharge Association (静电放电协会)

7900 Turin Road, Bldg. 3

Rome, NY 13440

版权属于静电放电协会,保留所有权力

未事先获得出版者的书面许可,本出版物的任何部分都不得以任何形式复制,在电子的可恢复系统中或其它形式。

印刷地:美国

ISBN:1-58537-121-1

美国国家标准学会(ANSI)/静电放电(ESD)协会标准 ANSI/ESD S20.20-2007

(本序言不是标准S20.20-2007的一部分)

序 言

本文件覆盖了,设计,建立,实施和维护一个静电放电(ESD)控制方案所必要的要求,该控制方案

适用领域包括:制造,处理,组装,安装,包装,标签,服务,测试,检验或其它在处理电气的或电

子的零件,装置和设备等,对静电放电损害的敏感度超过或等于人体模型的100V的情况。根据军方

和商用两方面机构的历史经验,本文件包括静电放电控制方案要求,并为处理静电放电敏感物体所建

立的控制方案提供指导。参考文献包括静电放电协会,美国军方和美国国家标准局所批准的有关材料

性质和测试方法的标准。本文件的基础是建立在静电放电控制的基本原则上

iv

A. 环境中的所有导体,包括人员,应该与一个已知接地或人造接地(如在船或飞机上)结

合在一起,或电气联接和相连。如此的连结在所有物体和人员之间建立了一个等电位平衡。只

要系统中所有的物体都处在同一个电位上,静电保护就可维持在高出地电位“零伏特”电压的电

位水平上。

B. 环境中的必要的非导体,不能通过与地连接,失去它们的静电荷。空气电离化为这些必

不可少的非导体提供了电荷中和的方式(电路板材料和一些器件的封装就是必不可少的非导体

的例子)。为保证配合静电放电敏感物体的合理的措施的实施,要求对工作场合中必要的非导体

上的静电荷所产生的静电放电危害,做出评估。

C. 静电放电敏感物体在静电放电保护区(文中以“静电保护区”)外运送时,要求用静电防护材

料密封起来,虽然材料的种类依赖于具体的情况和目的。在静电保护区内,低带电和静电耗散

材料能提供合适的防护。静电保护区外,推荐使用低带电和静电放电屏蔽材料。虽然,本文件

并没有讨论这类材料,但清楚地了解它们在应用中的差别是重要的。更多地阐明可参考标准

ANSI/ESD S541。

物体的任何相对移动和本体分离,或固体,液体及含有微粒的气体的流动,都能产生静电荷。

通常的静电放电源包括人员,常用的聚合物制成的物体,和制程设备。在下列情况下,静电放

电就会发生:

1一个带电物体接近并接触静电放电敏感器件,或

2当一个静电放电敏感器件暴露在一个静电场中的时候,将它接地。

微电子线路,分立的半导体器件,厚膜和薄膜电阻,混合器件,印刷电路板及压晶体管等,

就是一些静电放电敏感零件的例子。通过将一个器件置于模拟的静电放电过程中,可确定一

个器件和物体的敏感度。由模拟的静电放电过程所测试的敏感度等级,并不一定与实际情况

下的敏感度等级相同。但是,它们还是被用来建立一个敏感度数据的底线,以比较不同制造

商提供的同类产品。用于描述电子元器件特性的三个不同的模型是:人体放电模

型,机器模型(MM),和带电器件模型(CDM)。

v

美国国家标准学会(ANSI)/静电放电(ESD)协会标准 ANSI/ESD S20.20-2007

本标准最初版本为ANSI/ESDS20.20-1999并于1999年8月4日获得批准。ANSI/ESDS20.20-1999由

20.20 Mil-Std 1686转换委员会起草。ANSI/ESDS20.20-2007是ANSI/ESDS20.20-1999的一个修订

版本,由S20.20撰写小组起草,该小组成员为:

Ron Gibson

Celestica

Steve Gerken

USAF

下列人员为本文件做出了重要的贡献:

Jeremy Smallwood

Electrostatic Solution Ltd.

John T. Kinnear Jr

IBM

Reinhold Gaertner

Infineon Technologies

在ANSI/ESDS20.20-1999版本起草期间,20.20 Mil-Std 1686转换委员会成员为:

Steve Gerken, Co-Chairman

USAF

Dave Leeson, Co-Chairman

Motorola SSTG

David E. Swenson

3M

Anthony Klinowski

Boeing

Garry McGuire

NASA

(Hernandez Engineering)

Thomas Mohler

Raytheon Systems Corporation

下列人员为本文件做出了重要的贡献:

Ron Gibson

Celestica

Ronald L. Johnson

Intel

Robert Parr

Consultant

Joel Weidendorf

Consultant

Donal E. Cross

USN

Sheryl Zayic Boeing

Jeffrey Scanlon

ASC

John T. Kinnear Jr.

IBM

Robert Cummings

NASA

Ralph Myers

ASC

下列人员为本文件提供了中文版的翻译:

Deamer Wu (吴振忠)

MKS, Ion Systems

Dr. Guan Wei (管伟博士)

MKS, Ion Systems

vi

美国国家标准学会(ANSI)/静电放电(ESD)协会标准 ANSI/ESD S20.20-2007

目 录

1.0

2.0

3.0

4.0

5.0

6.0

6.1

6.2

6.3

7.0

7.2

7.3

8.0

8.1

8.2

8.3

8.4

8.5

附录 A - 其它的制程方面的考虑…………………………………………………………………………………………..7

附录 B - 敏感度测试……………………………………………………………………………………………………… 8

附录 C - 相关文件 …………………………………………………………………………………………………………10

目的……………………………………………………………………………………………………………1

范围……………………………………………………………………………………………………………1

参考出版物……………………………………………………………………………………………………1

定义……………………………………………………………………………………………………………2

工作人员安全…………………………………………………………………………………………………2

静电放电之控制方案…………………………………………………………………………………………2

静电放电控制方案的要求……………………………………………………………………………………2

静电放电控制方案之项目经理或协调员……………………………………………………………………2

修正……………………………………………………………………………………………………………2

静电放电控制方案之行政要求…………………………………………………………………………..…. 2

培训计划………………………………………………………………………………………………………2

认证检验计划…………………………………………………………………………………………………3

静电放电控制方案之技术要求………………………………………………………………………………3

接地 / 等电位相连系统………………………………………………………………………………………3

人员接地……………………………………………………………………………………………………… 3

静电放电保护区……………………………………………………………………………………………… 4

包装…………………………………………………………………………………………………………… 6

标记………………………………………………………………………………………………………… …6

.1 静电放电控制方案计划…………………………………………………………..…………………………… 2

表格目录

表 1 接地及等电位连接之要求……………………………………………………………………….

3

表 2 人员接地之要求…………………………………………………………………………………

4

表 3 静电放电保护区之静电放电控制项目……………………………………………………….…

5

表 4 器件的静电放电敏感度之测试参考………………………………………………………….…

8

表 5 装置和设备之静电放电敏感性测试参

考………………………………………………………………….9

vii

美国国家标准学会(ANSI)/静电放电(ESD)协会标准 ANSI/ESD S20.20-2007

建立一个静电放电控制方案的静电放电协会标准

电气和电子零件,装置和设备(不包括电动引爆装置)之静电放电保护

1.0 目的

本标准的目的是提供行政和技术上的要求,以及建立,实施和维护静电放电的控制方案(文中称"方案")。

2.0 范围

本标准所适用的领域包括:制造,处理,组装,安装,包装,标签,服务,测试,检验,运输以及其它除此之外,在

处理电气,电子零件,装置和设备中,对静电放电损害的敏感度超过或等于人体模型的100V的情况。对于敏感度小于

人体模型100V的情况,需要更多的控制项目和更严格的控制限定。本标准不适用于电动引爆设备,易燃液体和粉末。

3.0 参考出版物

除非特别指明,以下文献的最新版本,修正或校正,构成本 标准的一部分,作为特别补充。

ESD ADV 1.0

静电放电协会专门名词表1

ANSI/ESD S1.1

防静电手腕带1

ANSI/ESD STM 2.1

工作服1

ANSI EOS/ESD S3.1

电离化1

ANSI EOS/ESD SP3.3

空气电离器之定期检测1

ANSI/ESD S4.1

工作表面 - 电阻特性1

ANSI/ESD STM4.2

防静电工作表面 - 消电的特性1

ANSI EOS/ESD S 6.1

接地1

ANSI/ESD S 7.1

地板材料 - 材料特性1

ANSI/ESD STM9.1

鞋类 - 电阻特性1

ESD SP9.2

鞋类-脚部接地装置之电阻特性1

ANSI/ESD STM97.1

地板材料和鞋类 - 与人员相组合的电阻测量1

ANSI/ESD STM97.2

地板材料和鞋类 - 与人员相组合的电压测量1

ESD TR53

静电放电保护设备和材料之达标验证1

ANSI/ESD STM12.1

座椅 - 电阻测量1

ANSI/ESD S541

静电放电敏感物体之包装材料1

静电放电协会,

7900 Turin Road, Bldg 3, Ste 2, Rome, NY 13440-2069, 315-339-6937

1

美国国家标准学会(ANSI)/静电放电(ESD)协会标准 ANSI/ESD S20.20-2007

4.0

定义

本文件中所使用的用语与EOS/ESD协会的词汇表,EOS/ESD ADV 1.0,中的词汇,是相符合的。

5.0 工作人员安全

文件中描述的工作流程和设备,或许会导致操作人员暴露于有害的电气环境。本文件的使用者应自己负责选择符合

相关法律,管理条例和内外部政策的设备。用户要慎重地注意到,本标准不能替换或代替任何其它关于操作人员安

全的要求。无论在哪里,只要操作人员会与电源相接触的地方,接地断路器(GFCI)和其它安全保护措施应被采用。

减少电气伤害的操作应进行演习,必须遵从正确的机台接地指示。

6.0 静电放电和控制方案

6.1 静电放电控制方案的要求

如在此所描述的,该方案应包括行政和技术要求。根据这个方案,所处理的物体的最高敏感度被记录下来。按照本

文件的要求,使用单位应确立,记录,实施,维护该方案并核实方案的遵守情况。

6.2 静电放电控制方案之项目经理或协调员

按照本文件的要求,本文件的使用单位应指派一个负责核实静电放电方案实施情况的项目经理或协调员

6.3

修正

本标准,或其中的部份,可能不适用于所有的应用。通过评估每个要求对各具体应用的适用性,来完成方案的修正工

作。在完成了这个评估的基础上,可以增加,修改被删除各项具体应用的要求。对任何决定的修正,包括理论基础

和技术理由,都应记录在静电放电控制方案计划中 。

7.0

静电放电控制方案之行政要求

7.1

静电放电控制方案计划

各单位应制定一个静电放电控制方案计划,将方案中的每一个要求都一一列出。这些要求是:

• 培训

• 认证检验

• 接地及等电位相连系统

• 人员接地

• 静电放电保护区之要求

• 包装系统

• 标记

静电放电控制方案计划是实施和检验静电放电控制方案的首要档。其目标是全面实施和整合一个与内部质量系统要

求相符合的方案。该静电放电控制方案计划应适用于单位内部工作的各个方面。

7.2

培训计划

应对所有从事处理或接触静电放电敏感对象的工作人员提供初级和周期性的,有关静电放电知识和预防的培训。在

员工接触静电放电敏感对象之前,就应提供初级的培训。培训计划应为工作人员定下静电放电培训类型和频率。培

训计划应提出保留员工培训纪录的要求,并规定这些记录存放何处。培训的方法和具体技巧,由各单位选择。培训

计划还应包括用于检查学员理解及培训是否合适的检查方法。

2

美国国家标准学会(ANSI)/静电放电(ESD)协会标准 ANSI/ESD S20.20-2007

7.3

认证检验计划

认证检验计划的建立,是要确保单位能够满足静电放电方案计划的要求。认证检验计划应该明确要进行检验的技术要

求,相关的测试范围及认证频率。根据此计划进行认证检验。认证检验计划还应规定,检测和测试方法及设备。如果

单位采用的方法与本文件所列出的标准有差异,必须提供一个修改声明作为静电放电控制方案计划的一部分存盘。认证

检验纪录应该被确认并保存,以便证明符合了静电放电控制方案中的技术要求。所选择的测试设备应能够完成认证检验

计划中定义的测量项目。

8.0

静电放电控制方案计划之技术要求

以下章节,8.1到8.5,对建立静电放控制方案所用到的关键技术要求作了描述。

强制性的限定建立在每个表格所列出的测试方法或标准。认证检验计划应该规定用于检验这些限定的测试方法。

8.1

接地 / 等电位相连系统

接地 / 等电位相连接系统应被使用,以保证静电放电敏感对象、人员和所有其它导电体(如移动设备),处在同样的电

位。任

何一个实施方案,可从表格1中选择。

表格1:接地及等电位连接之要求

技术要求 实施方案 测试方法 强制限定

接地 / 等电位相连接系统

设备接地导体 ANSI/ESD S6.1

<1.0 欧姆阻抗

辅助接地

ANSI/ESD S6.1

< 25 欧姆到设备接地导体

等电位相连接 ANSI/ESD S6.1 <1.0x10

9

欧姆

1任何静电放电技术单元与公共接地点之间的最大电阻

8.2 人员接地

所有处理静电放电对象的人员都要与接地或等电位相连接系统实现电气连接。人员接地的方法,可从表格2选择。

注意:采用服装来实现人员接地的方法,必须在静电放电控制方案计划上注明。从服装的一个袖子到另一个袖子,

必须是导电的,而且,必须满足表格2的注释2所要求的电阻值。当工作人员坐在静电放电保护工作台前时,他们

必须通过手腕带系统与接地 / 等电位相连系统相连接。对于站立操作,工作人员必须通过手腕带系统或地板-鞋

系统接地。当采用地板-鞋系统时,应符合下面的两个条件:

A. 当系统的总电阻(从人体,通过鞋和地板,到接地/等电位相连系统)小于3.5×10

7

欧姆时,应采用方法1

(见表格2)。

B. 当系统的总电阻(从人体,通过鞋和地板,到接地/等电位相连系统)大于3.5×10

7

欧姆,但小于1×10

9

欧姆

时,应采用方法2(见表格2)

3

美国国家标准学会(ANSI)/静电放电(ESD)协会标准 ANSI/ESD S20.20-2007

表格2:人员接地之要求

手腕带系统

2

<3.5×10

7

欧姆

<3.5×10

7

欧姆

ESD TR53 有关手腕带章节

<3.5×10

7

欧姆

ESD TR53 有关地板章节

<3.5×10欧姆

地板 / 鞋系统 – 方法

ANSI/ESD STM97.1

1

ESD TR53 有关鞋类章节

<3.5×10欧姆

地板 / 鞋系统 – 方法

ANSI/ESD STM97.1

<10

9

欧姆

<1.0×10

9

欧姆

ESD TR53 有关地板章节

2

(两者都要求)

ANSI/ESD STM97.2

9

<100伏特

ESD TR53 有关鞋类章节

<1.0×10

欧姆

1在静电放电控制产品和材料的初始选择的时候采用产品合格检验。可采用的方法为:产品规范复查,独立实验室评估或内部实验室评估。

2在使用静电服作为手腕带接地通路的一部分的情况下,系统的总电阻,包括人体,服装和接地联机,应小于3.5×107欧姆。

人员接地之技术要求

产品合格检验

1

测试方法

ANSI/ESD S1.1

(5.11章节)

要求限定 测试方法

认证检验

要求限定

7

7

8.3

静电放电保护区

处理那些没有静电放电保护覆盖或包装的静电放电敏感零件,组装和设备,应在静电放电保护区内进行。静电放电保护

区的提醒告示应贴在工作人员进入静电放电保护区之前可清楚地看到的地方。

注意:一个静电放电保护区可以是一个单独的工作台,或整个房间,或整座建筑。

应该只限完成了相应的静电放电培训的人员,才能进入静电放电保护区,未经培训的个人进入静电放电保护区时,

应由受过培训的人员陪同

为了减少电场感应所导致的带电器件破坏模式,静电放电控制方案应包含对制程中所必要的绝缘材料的处理计划。如果电场

超过2000伏/英寸,应采取下列的步骤中的一个:

A. 将绝缘体与静电放电敏感器件分开30厘米(12英寸)的距离。

B. 使用空气电离化或其它电荷消除技术将电荷中和。

注意:静电场的精确测量要求测量人员要对测量设备的操作非常熟悉。大多数掌上型电场计要求在距离被测物体的一个固

定距离下读取数值。为了得到精确的测量,这些电场计还要规定被测物体的最小的尺寸。

所有的不必要的绝缘物体如咖啡杯,食物包装纸和个人物品都应从工作台或其它处理未加保护的静电放电敏感物体

的地方移走。

无论什么地方,只要有静电放电敏感产品,就要建立静电放电保护区。而在静电放电保护区内,可有不同的静电

放电控制方法。表格3列出了一些可用于控制静电的静电控制选择项目。对于那些在静电放电控制方案中选定的

静电控制项目,所要求的限定和测试方法是强制性的。

4

美国国家标准学会(ANSI)/静电放电(ESD)协会标准 ANSI/ESD S20.20-2007

表格3:静电放电保护区之静电放电控制项目

技术要求 静电放电控制项目

工作台

手腕带之接地线

手腕带之腕带部分

手腕带之接地线的弯折寿命

鞋类

地板接地装置

地板

坐椅

产品合格检验

1

测试方法

要求限定

2

ANSI/ESD S4.1

< 1× 10

9

欧姆

和/或

和/或

ANSI/ESD STM4.2

200伏特

ANSI/ESD S1.1

0.8× 10

6

欧姆 ~

1.2× 10

6

欧姆

内面

< 1× 10

5

欧姆

ANSI/ESD S1.1

外面

> 1× 10

7

欧姆

ANSI/ESD S1.1

>16,000次循环

ANSI/ESD STM9.1

< 1× 10

9

欧姆

ESD SP9.2

< 1× 10

9

欧姆

ANSI/ESD S7.1

< 1× 10

9

欧姆

ANSI/ESD STM12.1

< 1× 10

9

欧姆

认证检验

测试方法 要求限定

ESD TR53

< 1× 10

9

欧姆

工作表面章节

接地电阻

有关手腕带系统的认证检验,

见表格2

非环境系统之空气电离化

静电放电

保护区

ANSI/ESD STM3.1

- 消电时间

- 偏移电压

用户自定

<±50伏特

见表格2

见表格2

见表格2

ESD TR53

坐椅章节

ESD TR53

3

- 消电时间

- 偏移电压

见表格2

见表格2

见表格2

< 1× 10

9

欧姆

接地电阻

用户自定

<±50伏特

空气电离化(环境系统)

ANSI/ESD STM3.1

- 消电时间

- 偏移电压

用户自定

<±150伏特

< 1× 10

欧姆

9

ESD TR53

- 消电时间

- 偏移电压

3

用户自定

<±150伏特

货架

ANSI/ESD S4.1

移动设备(工作表面)

ANSI/ESD S4.1

< 1× 10

9

欧姆

连续监测

用户自定

用户自定

< 1× 10

欧姆

11

静电控制服

(ANSI/ESD STM2.1)

ESD TR53

工作表面章节

ESD TR53

移动设备章节

ESD TR53

连续监测章节

ESD TR53

服装章节

< 1× 10

9

欧姆

接地电阻

< 1× 10

9

欧姆

接地电阻

制造商自定

< 1× 10

11

欧姆

服装

可接地的静电控制服

(ANSI/ESD STM2.1)

< 1× 10

9

欧姆

ESD TR53

服装章节

< 1× 10

9

欧姆

可接地的静电控制服

系统

(ANSI/ESD STM2.1)

< 3.5× 10

7

欧姆

ESD TR53

服装章节

< 3.5× 10

7

欧姆

1在静电放电控制产品和材料的初始选择的时候采用产品合格检验。可采用的方法为:产品规范复查,独立实验室评估或内部实验室评估。

2对于包括多项电阻测试方法的标准,这些限定适用于所有方法。

3有关电离器的定期测试的更多信息,参考ANSI/ESD SP3.3。

5

美国国家标准学会(ANSI)/静电放电(ESD)协会标准 ANSI/ESD S20.20-2007

8.4 包装

静电放电保护包装应符合合同,采购订单,制图或其它文件。如果上述文件未作特殊说明,单位应该根据ANSI/ESD

S541,对静电放电保护区内外的静电放电包装作出定义。

8.5

标记

静电放电敏感物体,系统或包装的标记应符合客户合同,采购订单,制图或其它文件。当合同,采购订单,制图或其

它文件未对静电放电敏感物体,系统或包装的标记,未作特殊说明,单位在建立静电放电控制方案计划时,应考虑到

标记的需要。如果标记确定是需要的话,作为静电放电控制方案计划的一部分,将它档化

6

美国国家标准学会(ANSI)/静电放电(ESD)协会标准 ANSI/ESD S20.20-2007

(此附件不是ANSI/ESDS20.20 – 2007的一部分)

附件 A - 其它的制程方面的考虑

以下各章节为使用者提供用于评估其它控制产品和设备的指导性和提纲性的档。由于目前工业界尚未对这些项目给出

要求限定,使用者将需要建立他们自己的验收和认证检验准则。

1. 自动取放设备(ESD SP10.1,自动取放设备[AHE])。为了证实自动取放设备内部的静电放电控制,有必要去

测量机械部件的接地电阻,监测或验证经过该设备的产品上的静电荷。这既能提供静电放电次数测量的连续监测,

又能提供一个确定静电荷来源的方法。这项标准操作覆盖了机械部件的接地电阻测量和自动取放设备内部的电荷源确

定。

2. 手套(ANSI/ESD SP15.1使用中的手套和指套的电阻测量之标准操作)。这个标准操作的目的是为测量手套或

指套的本身电阻及测量操作人员带着手套或指套时的系统电阻提供测试规范。这个标准操作适用于所有用于控制静电

放电的手套和指套。这个标准操作所提供的数据与使用者的特定环境和应用相关联。

3. 手持工具(ESD STM13.1,电焊/电拆焊手持工具)。本文件为测量电焊/电拆焊手持工具的漏电流及工作头到接

地端的电阻提供了测量方法。还为安全的焊接操作提出了电疲劳(EOS)参数。尽管在STM13.1中没有专门讨论,电

池驱动,气动和其它手持工具或许也需要作评估。

4. 静电放电手册(TR20.20)。静电放电协会之标准委员会,为面对控制静电放电的个人和单位,编制了这份静电

放电手册。它提供了指导原则,能够用于建立,实施和监测与ANSI/ESD S20.20相符合的静电放电控制方案。这份手

册适用于:制造,处理,组装,安装,包装,标记,服务,测试,检测或其它处理对静电放电敏感度大于或等于

100伏特人体模式的电气或电子零件,装置和设备方面。

7

美国国家标准学会(ANSI)/静电放电(ESD)协会标准 ANSI/ESD S20.20-2007

(此附件不是ANSI/ESDS20.20 – 2007的一部分)

附录 B -

敏感度测试

要确定零件,装置和设备的静电放电敏感度及它们的强制性保护等级可能是静电放电控制方案中的一个重要的内容。通用

的确立静电放电敏感度的方法是,采用三个静电放电模型(人体模型,机器模型和带电器件模型)中的一个或多个模型来

描述电子产品的特性。挑选特定的静电放电控制流程或材料,是静电放电控制方案计划者的选择,同时也要依据危险评估

和所确立的零件,装置和设备的静电放电敏感度。

技术文献和失效分析资料表明,静电放电失效是由于一系列的,复杂的,相互关联的作用。一些影响静电放电敏感性的因

素,包括了静电放电电流和能量,静电放电的上升时间,零件设计,制造技术和零件包装样式。能量敏感器件的损坏是由

于,电流流过双极连接点,保护电阻器, 或金属氧化物半导体的保护晶体管。电压敏感器件的损坏是由于,电压超过了栅极

氧化层的击穿电压。电子器件的静电放电敏感性测试,无论是采用还是人体模型(HBM),机器模型(MM)还是带电器件

模型(CDM),都能提供一个静电放电敏感度,使之可用特定的参量与其它器件进行比较。任何特定模型所确定的器件之

静电放电敏感度(以伏特定义), 并不一定是在制造过程或使用中的实际失效电位水平。表格4为各种静电放电敏感性测试

的标准和测试方法提供了一个参考。

1.

人体模型敏感度(

HBM

依照由人体模型标准所作的模型,静电放电损坏来源于带电的人体。这个测试模型表示,放电从人体的指尖传到器件上的

导电管脚。该模型通过一个开关组件,将充了电的100 pF电容器,在待测器件和与之相串联的一个1500 欧姆电阻器上放

电。放电本身是有2~10纳秒上升时间,和大约150 纳秒脉冲宽度的双重指数信号波形。使用1500欧姆串联电阻器,意味着

这个模型接近一个电流源。所有器件都应该被视为HBM敏感。器件的人体模型静电放电敏感度,能通过选用一个参考的测

试方法去测试确定。人体模型敏感度可以在 RAC VZAP,合格制造商,产品列单(OML-19500) 或合格的制造商名单

(QML38535)中找到 。

2.

机器模型敏感度(

MM

机器模型的损害主要来源,是能量迅速地从一个带电的导电体传输到器件的导电管脚。这个静电放电模型是200 pF电容直

接对500 nH电感器放电,没有串联电阻。由于缺乏限制电流的串联电阻器,这个模型接近一个电压源。在现实中,这个模

型代表了物体之间的迅速放电,譬如带电的电路板装置,带电的电线或一个自动测试的传导手臂。放电本身是具有5~8纳秒

上升时间和大约80纳秒周期的正弦衰减波形。

3.

带电器件模型敏感度(

CDM

带电器件模型的损害主要来源,是能量从一个带电器件迅速地释放。 静电放电完全与器件相关,但器件与地电位面的相对

距离,却能影响实际的失效水平。该模型假定,当带电器件的导电管脚与具有较低的电位的导体表面接触时,会发生迅速

放电。带电器件模型测试标准的准备过程中的一个主要问题,是如何找到适当仪器测量放电过程。信号波形的上升时间经

常是少于200微微秒。整个过程可能发生在少于2.0纳秒的时间里。虽然时间非常短, 放电时电流却能达到几十安培的水平。

表 4:器件的静电放电敏感度之测量参考

静电放电模型

人体模型(HBM)

机器模型(MM)

带电器件模型(CDM)

器件的静电放电敏感度之测试标淮及方法

ANSI/ESD STM5.1

MIL-STD-883 方法3015

MIL-STD-750 方法1020

MIL-PRF-19500

MIL-PRF-38535

ESD-STM5.2

ESD DS5.3.1

8

美国国家标准学会(ANSI)/静电放电(ESD)协会标准 ANSI/ESD S20.20-2007

装置,设备和设计强化

1

装置,设备和设计强化指导原则

装置和设备应该有防护电路或技术,以达到所期待的设计目标。根据模拟模型,或实际测试,来确定在装置及设备

静电放电的敏感性。表5提供了一个与装置和设备敏感性测试相关联的,各种测试方法的快速参考。

2.

直接接触,非操作装置之身体

/

手指或手

/

金属测试

该模型可用于,检验在非操作情况下,装置不会因为直接接触到输入,输出及接口时而遭损坏。而这种危险存在于

所有类型的装置(请参考表格5)。

3.

直接接触操作中的设备之手

/

金属测试

该模型可用于,核实在正常维护过程中,运转的设备,不会因为直接接触到操作员可触到的接触点和暴露出来的表面,

而被损坏(或引起不可恢复性错误)。这种危险存在于,操作员正在进行调整或维护活动的,运转设备之中(请参考表

格5)。

4.

间接接触

,

操作中的设备之家具模型测试

该模型可用于,核实在正常工作时,家庭或办公室环境中操作的设备,不会因为设备附近间接接触而被损坏(或引起不

可恢复性错误)。这种危险存在于所有家庭或办公室环境里的电子设备(请参考表格5)。

表格 5:装置和设备之静电放电敏感性测试参考

静电放电装置/设备模型

人体/手指之人体模型(HBM)

静电放电测试标淮或方法

IEEE STD C62.38(次级装置)

手/金属之人体模型(HBM)

家具模型

IEC 1000-4-2

ANSI C63.16(设备)

9

美国国家标准学会(ANSI)/静电放电(ESD)协会标准 ANSI/ESD S20.20-2007

(此附件不是ANSI/ESDS20.20 – 2007的一部分)

附录 C - 相关文件

以下列出的文件提供进一步的参考。有些文件也许已被取消。然而, 这个目录提供了所有的,在本标准的准备中作为参考

的文件。

军用 / 美国政府文件

MIL-STD-3010, "联邦测试方法标准"

MIL-DTL-117, "包装袋,套管和管子内部包装"

MIL-PRF-81705, "隔离材料,灵活的,无静电的,加热密封的"

MIL-E-17555, "电子和电气设备,辅助配件,和临时对象 (维修件): 包装"

MIL-STD-1686, "保护电子和电气零件,装置,和设备(不包括电动引爆装置)之静电放电控制方案"

MIL-HDBK-263, "保护电子和电气零件,装置,和设备(不包括电动引爆装置)之静电放电控制手册"

MIL-M-38510, "军用微型电路的一般规格"

MIL-P-82646, "塑料膜,导电性的,加热密封的,灵活的"

MIL-PRF-87893, "工作站,静电放电(ESD) 控制"

MIL-STD-129, "运货和存贮标记"

MIL-STD-1285, "电子和电气零件之标记"

MMA-1985-79, 版本3,"评估犘擦生电的产生和衰减的标准测试方法"

工业标准

JESD 625A, "处理静电放电敏感(ESDS)器件的要求"

EIA-583, "湿气敏感产品的包装材料标准"

ESD-ADV3.2, "空气电离器的选择和验收"

ESDSIL, "可靠性分析中心 (RAC) 之静电放电敏感产品名单"

EIA-471, "静电敏感器件的标志和卷标'"

EN 61340-5-1, "电子器件的静电保护:一般规定"

IEC 61340-5-1, "电子器件的静电保护:一般规定"

VZAP, "静电放电敏感度数据"

10

- English 对照

Requirement – 要求

Program – 方案

Organization – 单位

Plan – 计划

Sensitivity – 敏感性,敏感度

Assembly – 装置,装配

Procedure – 流程

Guidance – 指导原则

ESDS – 静电放电敏感的

Code – 章程

Contrived Ground – 专用接地

Marking – 标记

Equipment – 设备

Handler – 取放机

Bonding – 连接

Ionization – 电离化

Susceptibility – 感受性,敏感性

Componente – 组件

Device – 器件

11

2024年8月26日发(作者:司空仙仪)

ANSI/ESD-S20.20-2007

ANSI/ESD-S20.20-1999

之修订版

建立一个

静电放电控制方案

电气和

电子零件,装置和设备

(不包括电动引爆装置)的保护

静电放电协会

7900 Turin Road, Bldg 3, Ste 2,

Rome, NY 13440‑ 2069

美国国家标准

2007年3月1日批准

ii

ESD Association Standards Committee

Standards Interpretation Bulletin

June 19, 2008

The ESD Association Standards Committee is issuing this interpretation bulletin regarding

ANSI/ESD S20.20-2007. This bulletin modifies the requirements specified in Table 3 EPA

Control Items (Garments). Table 3 should now be modified to disregard the two garment types;

“Groundable Static Control Garment” and “Groundable Static Control Garment System”, along

with their Test Methods and Requirements.

Additionally, the “Static Control Garment” Required Limit should be: 1 x 10

5

ohms to 1 x 10

11

ohms, per ANSI/ESD STM2.1-1997.

These changes are necessary because the referenced document, ANSI/ESD STM2.1, has been

brought back to a Work in Progress (WIP) status and therefore these two garment types

(mentioned above) are also brought back to WIP status.

Reference Information

Table 3. EPA ESD Control Items

Technical

Requirement

Product Qualification

Test Method

Static Control Garment

(ANSI/ESD STM2.1)

Groundable Static

Control Garment

(ANSI/ESD STM2.1)

Groundable Static

Control Garment

System

(ANSI/ESD STM2.1)

Required

2

Limit(s)

< 1 x 10

11

ohms

1

ESD Control

Item

Compliance Verification

Test Method

ESD TR53

Garments Section

ESD TR53

Garments Section

Required

Limit(s)

< 1 x 10

11

ohms

< 1 x 10

9

ohms

< 1 x 10

9

ohms

Garments

< 3.5 x 10

7

7

ohms

ESD TR53

Garments Section

< 3.5 x 10

7

7

ohms s

JohnKinnear

Working Group Chairman

Tim Jarrett

Standards Chairman

ESD Association Standards Committee

Standards Change Notification

June 14, 2007

This notification reports on two typos in ANSI/ESD S20.20-2007, Table 2 Personnel Grounding

Requirement. These corrections have been made to the Standard and are highlighted below for

your reference.

Previous Information

Table 2. Personnel Grounding Requirement

Personnel

Grounding

Technical

Requirement

Wrist Strap System

2

Product Qualification

Test Method

ANSI/ESD S1.1

(Section 5.10)

Required Limit(s)

0.8 x 10

6

to

1.2 x 10

6

ohms

1

Compliance Verification

Test Method

ESD TR53

Wrist Strap Section

Required Limit(s)

< 3.5 x 10

7

ohms

Current Information

Table 2. Personnel Grounding Requirement

Personnel

Grounding

Technical

Requirement

Wrist Strap System

2

Product Qualification

Test Method

ANSI/ESD S1.1

(Section 5.11)

Required Limit(s)

< 3.5 x 10

7

ohms

1

Compliance Verification

Test Method

ESD TR53

Wrist Strap Section

Required Limit(s)

< 3.5 x 10

7

ohms

John Kinnear

Working Group Chairman

Tim Jarrett

Standards Chairman

Comments can be sent to the ESD Association by one of the following methods:

Email: info@

Fax: 315-339-6793

美国国家标准学会(ANSI)/静电放电(ESD)协会标准 ANSI/ESD S20.20-2007

静电放电协会标准

建立一个静电放电控制方案

电气和电子零件,装置和设备

(

不包括电动引爆装置

)

的保护

静电放电协会2007年2月11日批准

iii

美国国家标准学会(ANSI)/静电放电(ESD)协会标准 ANSI/ESD S20.20-2007

提醒

静电放电协会(ESDA)之标准和出版物是为了公共利益,即消除制造商与买家之间的误

解,为产品的交流与改进提供方便,以及协助客户选择和获得他所特别需要的产品。

这些标准和出版物的存在,无论在那个方面,都不应妨碍本协会的任何会员或非会员

从事生产和销售并不符合这些标准和出版物的产品。同样,这些标准是由静电放电协

会所出版的事实,并不能妨碍非会员,无论是在国内还是国外,自愿地使用这些档。

遵循美国国家标准局的专利政策,静电放电协会采纳被推荐的标准和出版物。静电放

电协会标准之解释。就可能与特定的产品或制造商相关联的标准的解释,是涉及到具

体公司的关系重大的事情,不可能由任何人替代静电放电协会来做。静电放电协会主

席可以就标准中的技术语言或条款,作出仅限于说明性或澄清性的评论,但不能涉及

特定的产品和制造商。没有任何人被授权,以静电放电协会的名义来评论静电放电协

会之标准。

免责声明

出版者:

静电放电协会之标准和出版物的内容,以“照这样不作修改”的形式获得批准,静电放

电协会对相关内容,既不作专门陈述或保证,也不作表述或暗示。静电放电协会放弃

所有的抗议和保证,包括但并不局限于,商业化保证,特定目的和使用的合理性,标

题和其它非侵权行为。

免除担保:静电放电协会之标准和出版物,在它们被批准的时候,被认为是技术上可

靠的。它们不是用来替代所讨论之产品的商家或用户的自己的判断,而且,静电放电

协会不会,因这些标准和出版物,而对任何具体的制造商的产品的功能,承担任何担

保。因此,静电放电协会明确地拒绝,因使用,应用,或依赖于这些标准和出版物中

所包含信息,所导致的损害的任何责任。

静电放电协会之责任限制:静电放电协会,及它的会员,工作人员,雇员或其它代理

人员,都不对直接或间接地使用或误用静电放电标准或出版物所导致的损坏负责,即

使标准中提到了应用的可能性。这是适用于所有的各种损坏的综合性责任限制,包括

但并不局限于,资料,收入或利润的损失,财产的损失或损坏,以及第三方的索赔。

Electrostatic Discharge Association (静电放电协会)

7900 Turin Road, Bldg. 3

Rome, NY 13440

版权属于静电放电协会,保留所有权力

未事先获得出版者的书面许可,本出版物的任何部分都不得以任何形式复制,在电子的可恢复系统中或其它形式。

印刷地:美国

ISBN:1-58537-121-1

美国国家标准学会(ANSI)/静电放电(ESD)协会标准 ANSI/ESD S20.20-2007

(本序言不是标准S20.20-2007的一部分)

序 言

本文件覆盖了,设计,建立,实施和维护一个静电放电(ESD)控制方案所必要的要求,该控制方案

适用领域包括:制造,处理,组装,安装,包装,标签,服务,测试,检验或其它在处理电气的或电

子的零件,装置和设备等,对静电放电损害的敏感度超过或等于人体模型的100V的情况。根据军方

和商用两方面机构的历史经验,本文件包括静电放电控制方案要求,并为处理静电放电敏感物体所建

立的控制方案提供指导。参考文献包括静电放电协会,美国军方和美国国家标准局所批准的有关材料

性质和测试方法的标准。本文件的基础是建立在静电放电控制的基本原则上

iv

A. 环境中的所有导体,包括人员,应该与一个已知接地或人造接地(如在船或飞机上)结

合在一起,或电气联接和相连。如此的连结在所有物体和人员之间建立了一个等电位平衡。只

要系统中所有的物体都处在同一个电位上,静电保护就可维持在高出地电位“零伏特”电压的电

位水平上。

B. 环境中的必要的非导体,不能通过与地连接,失去它们的静电荷。空气电离化为这些必

不可少的非导体提供了电荷中和的方式(电路板材料和一些器件的封装就是必不可少的非导体

的例子)。为保证配合静电放电敏感物体的合理的措施的实施,要求对工作场合中必要的非导体

上的静电荷所产生的静电放电危害,做出评估。

C. 静电放电敏感物体在静电放电保护区(文中以“静电保护区”)外运送时,要求用静电防护材

料密封起来,虽然材料的种类依赖于具体的情况和目的。在静电保护区内,低带电和静电耗散

材料能提供合适的防护。静电保护区外,推荐使用低带电和静电放电屏蔽材料。虽然,本文件

并没有讨论这类材料,但清楚地了解它们在应用中的差别是重要的。更多地阐明可参考标准

ANSI/ESD S541。

物体的任何相对移动和本体分离,或固体,液体及含有微粒的气体的流动,都能产生静电荷。

通常的静电放电源包括人员,常用的聚合物制成的物体,和制程设备。在下列情况下,静电放

电就会发生:

1一个带电物体接近并接触静电放电敏感器件,或

2当一个静电放电敏感器件暴露在一个静电场中的时候,将它接地。

微电子线路,分立的半导体器件,厚膜和薄膜电阻,混合器件,印刷电路板及压晶体管等,

就是一些静电放电敏感零件的例子。通过将一个器件置于模拟的静电放电过程中,可确定一

个器件和物体的敏感度。由模拟的静电放电过程所测试的敏感度等级,并不一定与实际情况

下的敏感度等级相同。但是,它们还是被用来建立一个敏感度数据的底线,以比较不同制造

商提供的同类产品。用于描述电子元器件特性的三个不同的模型是:人体放电模

型,机器模型(MM),和带电器件模型(CDM)。

v

美国国家标准学会(ANSI)/静电放电(ESD)协会标准 ANSI/ESD S20.20-2007

本标准最初版本为ANSI/ESDS20.20-1999并于1999年8月4日获得批准。ANSI/ESDS20.20-1999由

20.20 Mil-Std 1686转换委员会起草。ANSI/ESDS20.20-2007是ANSI/ESDS20.20-1999的一个修订

版本,由S20.20撰写小组起草,该小组成员为:

Ron Gibson

Celestica

Steve Gerken

USAF

下列人员为本文件做出了重要的贡献:

Jeremy Smallwood

Electrostatic Solution Ltd.

John T. Kinnear Jr

IBM

Reinhold Gaertner

Infineon Technologies

在ANSI/ESDS20.20-1999版本起草期间,20.20 Mil-Std 1686转换委员会成员为:

Steve Gerken, Co-Chairman

USAF

Dave Leeson, Co-Chairman

Motorola SSTG

David E. Swenson

3M

Anthony Klinowski

Boeing

Garry McGuire

NASA

(Hernandez Engineering)

Thomas Mohler

Raytheon Systems Corporation

下列人员为本文件做出了重要的贡献:

Ron Gibson

Celestica

Ronald L. Johnson

Intel

Robert Parr

Consultant

Joel Weidendorf

Consultant

Donal E. Cross

USN

Sheryl Zayic Boeing

Jeffrey Scanlon

ASC

John T. Kinnear Jr.

IBM

Robert Cummings

NASA

Ralph Myers

ASC

下列人员为本文件提供了中文版的翻译:

Deamer Wu (吴振忠)

MKS, Ion Systems

Dr. Guan Wei (管伟博士)

MKS, Ion Systems

vi

美国国家标准学会(ANSI)/静电放电(ESD)协会标准 ANSI/ESD S20.20-2007

目 录

1.0

2.0

3.0

4.0

5.0

6.0

6.1

6.2

6.3

7.0

7.2

7.3

8.0

8.1

8.2

8.3

8.4

8.5

附录 A - 其它的制程方面的考虑…………………………………………………………………………………………..7

附录 B - 敏感度测试……………………………………………………………………………………………………… 8

附录 C - 相关文件 …………………………………………………………………………………………………………10

目的……………………………………………………………………………………………………………1

范围……………………………………………………………………………………………………………1

参考出版物……………………………………………………………………………………………………1

定义……………………………………………………………………………………………………………2

工作人员安全…………………………………………………………………………………………………2

静电放电之控制方案…………………………………………………………………………………………2

静电放电控制方案的要求……………………………………………………………………………………2

静电放电控制方案之项目经理或协调员……………………………………………………………………2

修正……………………………………………………………………………………………………………2

静电放电控制方案之行政要求…………………………………………………………………………..…. 2

培训计划………………………………………………………………………………………………………2

认证检验计划…………………………………………………………………………………………………3

静电放电控制方案之技术要求………………………………………………………………………………3

接地 / 等电位相连系统………………………………………………………………………………………3

人员接地……………………………………………………………………………………………………… 3

静电放电保护区……………………………………………………………………………………………… 4

包装…………………………………………………………………………………………………………… 6

标记………………………………………………………………………………………………………… …6

.1 静电放电控制方案计划…………………………………………………………..…………………………… 2

表格目录

表 1 接地及等电位连接之要求……………………………………………………………………….

3

表 2 人员接地之要求…………………………………………………………………………………

4

表 3 静电放电保护区之静电放电控制项目……………………………………………………….…

5

表 4 器件的静电放电敏感度之测试参考………………………………………………………….…

8

表 5 装置和设备之静电放电敏感性测试参

考………………………………………………………………….9

vii

美国国家标准学会(ANSI)/静电放电(ESD)协会标准 ANSI/ESD S20.20-2007

建立一个静电放电控制方案的静电放电协会标准

电气和电子零件,装置和设备(不包括电动引爆装置)之静电放电保护

1.0 目的

本标准的目的是提供行政和技术上的要求,以及建立,实施和维护静电放电的控制方案(文中称"方案")。

2.0 范围

本标准所适用的领域包括:制造,处理,组装,安装,包装,标签,服务,测试,检验,运输以及其它除此之外,在

处理电气,电子零件,装置和设备中,对静电放电损害的敏感度超过或等于人体模型的100V的情况。对于敏感度小于

人体模型100V的情况,需要更多的控制项目和更严格的控制限定。本标准不适用于电动引爆设备,易燃液体和粉末。

3.0 参考出版物

除非特别指明,以下文献的最新版本,修正或校正,构成本 标准的一部分,作为特别补充。

ESD ADV 1.0

静电放电协会专门名词表1

ANSI/ESD S1.1

防静电手腕带1

ANSI/ESD STM 2.1

工作服1

ANSI EOS/ESD S3.1

电离化1

ANSI EOS/ESD SP3.3

空气电离器之定期检测1

ANSI/ESD S4.1

工作表面 - 电阻特性1

ANSI/ESD STM4.2

防静电工作表面 - 消电的特性1

ANSI EOS/ESD S 6.1

接地1

ANSI/ESD S 7.1

地板材料 - 材料特性1

ANSI/ESD STM9.1

鞋类 - 电阻特性1

ESD SP9.2

鞋类-脚部接地装置之电阻特性1

ANSI/ESD STM97.1

地板材料和鞋类 - 与人员相组合的电阻测量1

ANSI/ESD STM97.2

地板材料和鞋类 - 与人员相组合的电压测量1

ESD TR53

静电放电保护设备和材料之达标验证1

ANSI/ESD STM12.1

座椅 - 电阻测量1

ANSI/ESD S541

静电放电敏感物体之包装材料1

静电放电协会,

7900 Turin Road, Bldg 3, Ste 2, Rome, NY 13440-2069, 315-339-6937

1

美国国家标准学会(ANSI)/静电放电(ESD)协会标准 ANSI/ESD S20.20-2007

4.0

定义

本文件中所使用的用语与EOS/ESD协会的词汇表,EOS/ESD ADV 1.0,中的词汇,是相符合的。

5.0 工作人员安全

文件中描述的工作流程和设备,或许会导致操作人员暴露于有害的电气环境。本文件的使用者应自己负责选择符合

相关法律,管理条例和内外部政策的设备。用户要慎重地注意到,本标准不能替换或代替任何其它关于操作人员安

全的要求。无论在哪里,只要操作人员会与电源相接触的地方,接地断路器(GFCI)和其它安全保护措施应被采用。

减少电气伤害的操作应进行演习,必须遵从正确的机台接地指示。

6.0 静电放电和控制方案

6.1 静电放电控制方案的要求

如在此所描述的,该方案应包括行政和技术要求。根据这个方案,所处理的物体的最高敏感度被记录下来。按照本

文件的要求,使用单位应确立,记录,实施,维护该方案并核实方案的遵守情况。

6.2 静电放电控制方案之项目经理或协调员

按照本文件的要求,本文件的使用单位应指派一个负责核实静电放电方案实施情况的项目经理或协调员

6.3

修正

本标准,或其中的部份,可能不适用于所有的应用。通过评估每个要求对各具体应用的适用性,来完成方案的修正工

作。在完成了这个评估的基础上,可以增加,修改被删除各项具体应用的要求。对任何决定的修正,包括理论基础

和技术理由,都应记录在静电放电控制方案计划中 。

7.0

静电放电控制方案之行政要求

7.1

静电放电控制方案计划

各单位应制定一个静电放电控制方案计划,将方案中的每一个要求都一一列出。这些要求是:

• 培训

• 认证检验

• 接地及等电位相连系统

• 人员接地

• 静电放电保护区之要求

• 包装系统

• 标记

静电放电控制方案计划是实施和检验静电放电控制方案的首要档。其目标是全面实施和整合一个与内部质量系统要

求相符合的方案。该静电放电控制方案计划应适用于单位内部工作的各个方面。

7.2

培训计划

应对所有从事处理或接触静电放电敏感对象的工作人员提供初级和周期性的,有关静电放电知识和预防的培训。在

员工接触静电放电敏感对象之前,就应提供初级的培训。培训计划应为工作人员定下静电放电培训类型和频率。培

训计划应提出保留员工培训纪录的要求,并规定这些记录存放何处。培训的方法和具体技巧,由各单位选择。培训

计划还应包括用于检查学员理解及培训是否合适的检查方法。

2

美国国家标准学会(ANSI)/静电放电(ESD)协会标准 ANSI/ESD S20.20-2007

7.3

认证检验计划

认证检验计划的建立,是要确保单位能够满足静电放电方案计划的要求。认证检验计划应该明确要进行检验的技术要

求,相关的测试范围及认证频率。根据此计划进行认证检验。认证检验计划还应规定,检测和测试方法及设备。如果

单位采用的方法与本文件所列出的标准有差异,必须提供一个修改声明作为静电放电控制方案计划的一部分存盘。认证

检验纪录应该被确认并保存,以便证明符合了静电放电控制方案中的技术要求。所选择的测试设备应能够完成认证检验

计划中定义的测量项目。

8.0

静电放电控制方案计划之技术要求

以下章节,8.1到8.5,对建立静电放控制方案所用到的关键技术要求作了描述。

强制性的限定建立在每个表格所列出的测试方法或标准。认证检验计划应该规定用于检验这些限定的测试方法。

8.1

接地 / 等电位相连系统

接地 / 等电位相连接系统应被使用,以保证静电放电敏感对象、人员和所有其它导电体(如移动设备),处在同样的电

位。任

何一个实施方案,可从表格1中选择。

表格1:接地及等电位连接之要求

技术要求 实施方案 测试方法 强制限定

接地 / 等电位相连接系统

设备接地导体 ANSI/ESD S6.1

<1.0 欧姆阻抗

辅助接地

ANSI/ESD S6.1

< 25 欧姆到设备接地导体

等电位相连接 ANSI/ESD S6.1 <1.0x10

9

欧姆

1任何静电放电技术单元与公共接地点之间的最大电阻

8.2 人员接地

所有处理静电放电对象的人员都要与接地或等电位相连接系统实现电气连接。人员接地的方法,可从表格2选择。

注意:采用服装来实现人员接地的方法,必须在静电放电控制方案计划上注明。从服装的一个袖子到另一个袖子,

必须是导电的,而且,必须满足表格2的注释2所要求的电阻值。当工作人员坐在静电放电保护工作台前时,他们

必须通过手腕带系统与接地 / 等电位相连系统相连接。对于站立操作,工作人员必须通过手腕带系统或地板-鞋

系统接地。当采用地板-鞋系统时,应符合下面的两个条件:

A. 当系统的总电阻(从人体,通过鞋和地板,到接地/等电位相连系统)小于3.5×10

7

欧姆时,应采用方法1

(见表格2)。

B. 当系统的总电阻(从人体,通过鞋和地板,到接地/等电位相连系统)大于3.5×10

7

欧姆,但小于1×10

9

欧姆

时,应采用方法2(见表格2)

3

美国国家标准学会(ANSI)/静电放电(ESD)协会标准 ANSI/ESD S20.20-2007

表格2:人员接地之要求

手腕带系统

2

<3.5×10

7

欧姆

<3.5×10

7

欧姆

ESD TR53 有关手腕带章节

<3.5×10

7

欧姆

ESD TR53 有关地板章节

<3.5×10欧姆

地板 / 鞋系统 – 方法

ANSI/ESD STM97.1

1

ESD TR53 有关鞋类章节

<3.5×10欧姆

地板 / 鞋系统 – 方法

ANSI/ESD STM97.1

<10

9

欧姆

<1.0×10

9

欧姆

ESD TR53 有关地板章节

2

(两者都要求)

ANSI/ESD STM97.2

9

<100伏特

ESD TR53 有关鞋类章节

<1.0×10

欧姆

1在静电放电控制产品和材料的初始选择的时候采用产品合格检验。可采用的方法为:产品规范复查,独立实验室评估或内部实验室评估。

2在使用静电服作为手腕带接地通路的一部分的情况下,系统的总电阻,包括人体,服装和接地联机,应小于3.5×107欧姆。

人员接地之技术要求

产品合格检验

1

测试方法

ANSI/ESD S1.1

(5.11章节)

要求限定 测试方法

认证检验

要求限定

7

7

8.3

静电放电保护区

处理那些没有静电放电保护覆盖或包装的静电放电敏感零件,组装和设备,应在静电放电保护区内进行。静电放电保护

区的提醒告示应贴在工作人员进入静电放电保护区之前可清楚地看到的地方。

注意:一个静电放电保护区可以是一个单独的工作台,或整个房间,或整座建筑。

应该只限完成了相应的静电放电培训的人员,才能进入静电放电保护区,未经培训的个人进入静电放电保护区时,

应由受过培训的人员陪同

为了减少电场感应所导致的带电器件破坏模式,静电放电控制方案应包含对制程中所必要的绝缘材料的处理计划。如果电场

超过2000伏/英寸,应采取下列的步骤中的一个:

A. 将绝缘体与静电放电敏感器件分开30厘米(12英寸)的距离。

B. 使用空气电离化或其它电荷消除技术将电荷中和。

注意:静电场的精确测量要求测量人员要对测量设备的操作非常熟悉。大多数掌上型电场计要求在距离被测物体的一个固

定距离下读取数值。为了得到精确的测量,这些电场计还要规定被测物体的最小的尺寸。

所有的不必要的绝缘物体如咖啡杯,食物包装纸和个人物品都应从工作台或其它处理未加保护的静电放电敏感物体

的地方移走。

无论什么地方,只要有静电放电敏感产品,就要建立静电放电保护区。而在静电放电保护区内,可有不同的静电

放电控制方法。表格3列出了一些可用于控制静电的静电控制选择项目。对于那些在静电放电控制方案中选定的

静电控制项目,所要求的限定和测试方法是强制性的。

4

美国国家标准学会(ANSI)/静电放电(ESD)协会标准 ANSI/ESD S20.20-2007

表格3:静电放电保护区之静电放电控制项目

技术要求 静电放电控制项目

工作台

手腕带之接地线

手腕带之腕带部分

手腕带之接地线的弯折寿命

鞋类

地板接地装置

地板

坐椅

产品合格检验

1

测试方法

要求限定

2

ANSI/ESD S4.1

< 1× 10

9

欧姆

和/或

和/或

ANSI/ESD STM4.2

200伏特

ANSI/ESD S1.1

0.8× 10

6

欧姆 ~

1.2× 10

6

欧姆

内面

< 1× 10

5

欧姆

ANSI/ESD S1.1

外面

> 1× 10

7

欧姆

ANSI/ESD S1.1

>16,000次循环

ANSI/ESD STM9.1

< 1× 10

9

欧姆

ESD SP9.2

< 1× 10

9

欧姆

ANSI/ESD S7.1

< 1× 10

9

欧姆

ANSI/ESD STM12.1

< 1× 10

9

欧姆

认证检验

测试方法 要求限定

ESD TR53

< 1× 10

9

欧姆

工作表面章节

接地电阻

有关手腕带系统的认证检验,

见表格2

非环境系统之空气电离化

静电放电

保护区

ANSI/ESD STM3.1

- 消电时间

- 偏移电压

用户自定

<±50伏特

见表格2

见表格2

见表格2

ESD TR53

坐椅章节

ESD TR53

3

- 消电时间

- 偏移电压

见表格2

见表格2

见表格2

< 1× 10

9

欧姆

接地电阻

用户自定

<±50伏特

空气电离化(环境系统)

ANSI/ESD STM3.1

- 消电时间

- 偏移电压

用户自定

<±150伏特

< 1× 10

欧姆

9

ESD TR53

- 消电时间

- 偏移电压

3

用户自定

<±150伏特

货架

ANSI/ESD S4.1

移动设备(工作表面)

ANSI/ESD S4.1

< 1× 10

9

欧姆

连续监测

用户自定

用户自定

< 1× 10

欧姆

11

静电控制服

(ANSI/ESD STM2.1)

ESD TR53

工作表面章节

ESD TR53

移动设备章节

ESD TR53

连续监测章节

ESD TR53

服装章节

< 1× 10

9

欧姆

接地电阻

< 1× 10

9

欧姆

接地电阻

制造商自定

< 1× 10

11

欧姆

服装

可接地的静电控制服

(ANSI/ESD STM2.1)

< 1× 10

9

欧姆

ESD TR53

服装章节

< 1× 10

9

欧姆

可接地的静电控制服

系统

(ANSI/ESD STM2.1)

< 3.5× 10

7

欧姆

ESD TR53

服装章节

< 3.5× 10

7

欧姆

1在静电放电控制产品和材料的初始选择的时候采用产品合格检验。可采用的方法为:产品规范复查,独立实验室评估或内部实验室评估。

2对于包括多项电阻测试方法的标准,这些限定适用于所有方法。

3有关电离器的定期测试的更多信息,参考ANSI/ESD SP3.3。

5

美国国家标准学会(ANSI)/静电放电(ESD)协会标准 ANSI/ESD S20.20-2007

8.4 包装

静电放电保护包装应符合合同,采购订单,制图或其它文件。如果上述文件未作特殊说明,单位应该根据ANSI/ESD

S541,对静电放电保护区内外的静电放电包装作出定义。

8.5

标记

静电放电敏感物体,系统或包装的标记应符合客户合同,采购订单,制图或其它文件。当合同,采购订单,制图或其

它文件未对静电放电敏感物体,系统或包装的标记,未作特殊说明,单位在建立静电放电控制方案计划时,应考虑到

标记的需要。如果标记确定是需要的话,作为静电放电控制方案计划的一部分,将它档化

6

美国国家标准学会(ANSI)/静电放电(ESD)协会标准 ANSI/ESD S20.20-2007

(此附件不是ANSI/ESDS20.20 – 2007的一部分)

附件 A - 其它的制程方面的考虑

以下各章节为使用者提供用于评估其它控制产品和设备的指导性和提纲性的档。由于目前工业界尚未对这些项目给出

要求限定,使用者将需要建立他们自己的验收和认证检验准则。

1. 自动取放设备(ESD SP10.1,自动取放设备[AHE])。为了证实自动取放设备内部的静电放电控制,有必要去

测量机械部件的接地电阻,监测或验证经过该设备的产品上的静电荷。这既能提供静电放电次数测量的连续监测,

又能提供一个确定静电荷来源的方法。这项标准操作覆盖了机械部件的接地电阻测量和自动取放设备内部的电荷源确

定。

2. 手套(ANSI/ESD SP15.1使用中的手套和指套的电阻测量之标准操作)。这个标准操作的目的是为测量手套或

指套的本身电阻及测量操作人员带着手套或指套时的系统电阻提供测试规范。这个标准操作适用于所有用于控制静电

放电的手套和指套。这个标准操作所提供的数据与使用者的特定环境和应用相关联。

3. 手持工具(ESD STM13.1,电焊/电拆焊手持工具)。本文件为测量电焊/电拆焊手持工具的漏电流及工作头到接

地端的电阻提供了测量方法。还为安全的焊接操作提出了电疲劳(EOS)参数。尽管在STM13.1中没有专门讨论,电

池驱动,气动和其它手持工具或许也需要作评估。

4. 静电放电手册(TR20.20)。静电放电协会之标准委员会,为面对控制静电放电的个人和单位,编制了这份静电

放电手册。它提供了指导原则,能够用于建立,实施和监测与ANSI/ESD S20.20相符合的静电放电控制方案。这份手

册适用于:制造,处理,组装,安装,包装,标记,服务,测试,检测或其它处理对静电放电敏感度大于或等于

100伏特人体模式的电气或电子零件,装置和设备方面。

7

美国国家标准学会(ANSI)/静电放电(ESD)协会标准 ANSI/ESD S20.20-2007

(此附件不是ANSI/ESDS20.20 – 2007的一部分)

附录 B -

敏感度测试

要确定零件,装置和设备的静电放电敏感度及它们的强制性保护等级可能是静电放电控制方案中的一个重要的内容。通用

的确立静电放电敏感度的方法是,采用三个静电放电模型(人体模型,机器模型和带电器件模型)中的一个或多个模型来

描述电子产品的特性。挑选特定的静电放电控制流程或材料,是静电放电控制方案计划者的选择,同时也要依据危险评估

和所确立的零件,装置和设备的静电放电敏感度。

技术文献和失效分析资料表明,静电放电失效是由于一系列的,复杂的,相互关联的作用。一些影响静电放电敏感性的因

素,包括了静电放电电流和能量,静电放电的上升时间,零件设计,制造技术和零件包装样式。能量敏感器件的损坏是由

于,电流流过双极连接点,保护电阻器, 或金属氧化物半导体的保护晶体管。电压敏感器件的损坏是由于,电压超过了栅极

氧化层的击穿电压。电子器件的静电放电敏感性测试,无论是采用还是人体模型(HBM),机器模型(MM)还是带电器件

模型(CDM),都能提供一个静电放电敏感度,使之可用特定的参量与其它器件进行比较。任何特定模型所确定的器件之

静电放电敏感度(以伏特定义), 并不一定是在制造过程或使用中的实际失效电位水平。表格4为各种静电放电敏感性测试

的标准和测试方法提供了一个参考。

1.

人体模型敏感度(

HBM

依照由人体模型标准所作的模型,静电放电损坏来源于带电的人体。这个测试模型表示,放电从人体的指尖传到器件上的

导电管脚。该模型通过一个开关组件,将充了电的100 pF电容器,在待测器件和与之相串联的一个1500 欧姆电阻器上放

电。放电本身是有2~10纳秒上升时间,和大约150 纳秒脉冲宽度的双重指数信号波形。使用1500欧姆串联电阻器,意味着

这个模型接近一个电流源。所有器件都应该被视为HBM敏感。器件的人体模型静电放电敏感度,能通过选用一个参考的测

试方法去测试确定。人体模型敏感度可以在 RAC VZAP,合格制造商,产品列单(OML-19500) 或合格的制造商名单

(QML38535)中找到 。

2.

机器模型敏感度(

MM

机器模型的损害主要来源,是能量迅速地从一个带电的导电体传输到器件的导电管脚。这个静电放电模型是200 pF电容直

接对500 nH电感器放电,没有串联电阻。由于缺乏限制电流的串联电阻器,这个模型接近一个电压源。在现实中,这个模

型代表了物体之间的迅速放电,譬如带电的电路板装置,带电的电线或一个自动测试的传导手臂。放电本身是具有5~8纳秒

上升时间和大约80纳秒周期的正弦衰减波形。

3.

带电器件模型敏感度(

CDM

带电器件模型的损害主要来源,是能量从一个带电器件迅速地释放。 静电放电完全与器件相关,但器件与地电位面的相对

距离,却能影响实际的失效水平。该模型假定,当带电器件的导电管脚与具有较低的电位的导体表面接触时,会发生迅速

放电。带电器件模型测试标准的准备过程中的一个主要问题,是如何找到适当仪器测量放电过程。信号波形的上升时间经

常是少于200微微秒。整个过程可能发生在少于2.0纳秒的时间里。虽然时间非常短, 放电时电流却能达到几十安培的水平。

表 4:器件的静电放电敏感度之测量参考

静电放电模型

人体模型(HBM)

机器模型(MM)

带电器件模型(CDM)

器件的静电放电敏感度之测试标淮及方法

ANSI/ESD STM5.1

MIL-STD-883 方法3015

MIL-STD-750 方法1020

MIL-PRF-19500

MIL-PRF-38535

ESD-STM5.2

ESD DS5.3.1

8

美国国家标准学会(ANSI)/静电放电(ESD)协会标准 ANSI/ESD S20.20-2007

装置,设备和设计强化

1

装置,设备和设计强化指导原则

装置和设备应该有防护电路或技术,以达到所期待的设计目标。根据模拟模型,或实际测试,来确定在装置及设备

静电放电的敏感性。表5提供了一个与装置和设备敏感性测试相关联的,各种测试方法的快速参考。

2.

直接接触,非操作装置之身体

/

手指或手

/

金属测试

该模型可用于,检验在非操作情况下,装置不会因为直接接触到输入,输出及接口时而遭损坏。而这种危险存在于

所有类型的装置(请参考表格5)。

3.

直接接触操作中的设备之手

/

金属测试

该模型可用于,核实在正常维护过程中,运转的设备,不会因为直接接触到操作员可触到的接触点和暴露出来的表面,

而被损坏(或引起不可恢复性错误)。这种危险存在于,操作员正在进行调整或维护活动的,运转设备之中(请参考表

格5)。

4.

间接接触

,

操作中的设备之家具模型测试

该模型可用于,核实在正常工作时,家庭或办公室环境中操作的设备,不会因为设备附近间接接触而被损坏(或引起不

可恢复性错误)。这种危险存在于所有家庭或办公室环境里的电子设备(请参考表格5)。

表格 5:装置和设备之静电放电敏感性测试参考

静电放电装置/设备模型

人体/手指之人体模型(HBM)

静电放电测试标淮或方法

IEEE STD C62.38(次级装置)

手/金属之人体模型(HBM)

家具模型

IEC 1000-4-2

ANSI C63.16(设备)

9

美国国家标准学会(ANSI)/静电放电(ESD)协会标准 ANSI/ESD S20.20-2007

(此附件不是ANSI/ESDS20.20 – 2007的一部分)

附录 C - 相关文件

以下列出的文件提供进一步的参考。有些文件也许已被取消。然而, 这个目录提供了所有的,在本标准的准备中作为参考

的文件。

军用 / 美国政府文件

MIL-STD-3010, "联邦测试方法标准"

MIL-DTL-117, "包装袋,套管和管子内部包装"

MIL-PRF-81705, "隔离材料,灵活的,无静电的,加热密封的"

MIL-E-17555, "电子和电气设备,辅助配件,和临时对象 (维修件): 包装"

MIL-STD-1686, "保护电子和电气零件,装置,和设备(不包括电动引爆装置)之静电放电控制方案"

MIL-HDBK-263, "保护电子和电气零件,装置,和设备(不包括电动引爆装置)之静电放电控制手册"

MIL-M-38510, "军用微型电路的一般规格"

MIL-P-82646, "塑料膜,导电性的,加热密封的,灵活的"

MIL-PRF-87893, "工作站,静电放电(ESD) 控制"

MIL-STD-129, "运货和存贮标记"

MIL-STD-1285, "电子和电气零件之标记"

MMA-1985-79, 版本3,"评估犘擦生电的产生和衰减的标准测试方法"

工业标准

JESD 625A, "处理静电放电敏感(ESDS)器件的要求"

EIA-583, "湿气敏感产品的包装材料标准"

ESD-ADV3.2, "空气电离器的选择和验收"

ESDSIL, "可靠性分析中心 (RAC) 之静电放电敏感产品名单"

EIA-471, "静电敏感器件的标志和卷标'"

EN 61340-5-1, "电子器件的静电保护:一般规定"

IEC 61340-5-1, "电子器件的静电保护:一般规定"

VZAP, "静电放电敏感度数据"

10

- English 对照

Requirement – 要求

Program – 方案

Organization – 单位

Plan – 计划

Sensitivity – 敏感性,敏感度

Assembly – 装置,装配

Procedure – 流程

Guidance – 指导原则

ESDS – 静电放电敏感的

Code – 章程

Contrived Ground – 专用接地

Marking – 标记

Equipment – 设备

Handler – 取放机

Bonding – 连接

Ionization – 电离化

Susceptibility – 感受性,敏感性

Componente – 组件

Device – 器件

11

发布评论

评论列表 (0)

  1. 暂无评论