2024年9月6日发(作者:瑞文静)
P
RESSURE
T
RANSMITTER
PASCAL CV
FOR
FOOD
/
PHARMACEUTICALS
/
BIOTECHNOLOGY
T
YPE
S
ERIES
CV 3110
Design Features
■
Modular pressure transmitter with diaphragm seal technology
Signal output::
®
●
4..20 mA, can be retrofitted with optional HART
protocol
●
PROFIBUS PA
■
Function modules
●
Multifunctional display with 5-segment digital display and bar graph
®
●
HART
protocol
●
Switching module with 2 floating channels, maximum 1.5 A
switching current, electrically isolated at all sides, without additional
auxiliary power
■
Function module replacement on site without recalibration
"plug and measure"
■
Watchdog for electronics modules and measuring cell
■
Hygienic design according to EHEDG, FDA und GMP recommendations
■
Material and surface quality according to the hygienic requirements
■
Limits of measuring 80 mbar 40 bar
■
Accuracy: < 0.25% (linearity, hysteresis and repeatability)
■
Turndown 5:1
■
Explosion protection: II 1/2G EEx ia IIC T6
■
Medium temperature up to 160 °C
■
Piezoresistive measuring cell, directly aerated, fully welded
Application
The pressure transmitter PASCAL CV is suited for measuring the relative
and absolute pressures of gases, vapors and liquids. The type series
CV3110 has been developed to meet the stringent demands of food
processing, pharmaceutical technology, and biotechnology. Special attention
has been given to good surface quality. Thus, for instance, roughness
values to Ra 0.4 µm can be guaranteed for wetted parts (for welds: Ra < 0.8
µm) or the system can be electropolished as well.
The modular design of the pressure transmitter allows users to choose the
best possible device for his specific operating requirements.
PASCAL CV is equipped with a variety of process connections and uses
smart module technology for display, switching and communication purposes.
These functional modules can be exchanged or extended with ease without
having to remove the transmitter from the process.
Other designs available
●
PASCAL CV 3100 for general application
●
PASCAL CV 3120 for chemical/petrochemical industry
Basic module
4...20 mA
Function modules
HART
®
-module
Switching
module
Display
module
PROFIBUS
Process connection: all standard screw-in, flange and inline connections
P. 1
Data Sheet: D4-017/2
Rev. 0D3
Instrument ranges
nominal rangeTurndownmeasuring
ranges
measuring spans
min. spanmax. span
overload
limits
vaccum
tight at < 50 °C
0.4 bar - +0.4 bar80 mbar
1 bar -1 ... + 1 bar0.2 bar
4 bar -1 ... + 4 bar0.8 bar
16 bar
5 : 1
-1 ... + 16 bar3.2 bar
40 bar -1 ... + 40 bar8 bar
4 bar abs0 ... 4 bar abs0.8 bar abs
16 bar abs0 ... 16 bar abs3.2 bar abs
limits of measuring range
-100 %
nominal range: e.g. 1 bar
-1bar
Housing design
Housinghygienic housing design with
screw cap and window
Materialhousing:stainless steel . 1.4301
window:Macrolon
gasket:NBR O-ring
Constructiontwo-chamber system, minimum housing
volume, excellent moisture and
condensate protection
Pressure compensationPTFE filter system
Degree of protectionEN 60529, IP 66
Climatic categoryDIN EN 60721 3-4, 4K4H
Electrical connection· screwed terminals 1 mm², cable entry
fitting through screwing
· circular plug connector M 12
Weightstandard device without diaphragm seal
andfunction modules approx. 0.65 kg
Housing design
windows
separate terminal compartment
(reduced volume)
O-ring-
seal
terminals
electronics
fully encapsulated
replaceable
cable entry fitting
gasket
atmospheric pressure
plug connection
compensation
sensor chamber
fully encapsulated
pressure sensor with direct
(reduced volume)
connection to atmospheric
pressure compensation
Process connection
Constructionwelded design
Diaphragmmodifications see page 5 or order code
Materialstainless steel mat.-no. 1.4404 or 1.4435
see order code
Measuring system
Sensorpiezoresistive measuring element
System fillfoodstuff oil FD1 (USDA-H1)
according to FDA
Temperature ranges
Ambient temperature-20 to 85°C
Process temperaturedepending on design
Allowed 85 °C
Note safety values as per examination certificate!
Supply
40 VDC
30 VDC
Approval/tests
Interference emissionEN 50081 section 1
Noise immunityEN 50082 section 2
EU examination certificateII 1/2G EEx ia IIC T6
0.8 bar2 bar400 mbar abs
2 bar7 bar 40 mbar abs
5 bar20 bar 20 mbar abs
17 bar100 bar 20 mbar abs
41 bar100 bar 20 mbar abs
4 bar abs20 bar abs 20 mbar abs
16 bar abs100 bar abs 20 mbar abs
0%
meas. span
100%
0bar
0.2 bar
1 bar
up to 2 bar
Output
20 mA, two-wire,
optional with HART protocol (not yet available)
Current range3.8 - 20.8 mA
Current limitationapprox. 22 mA
Alarm state< 3.6 mA, optional > 21 mA
Delay timeapprox. 160 ms
measuring cycle6 measurements / second
Measuring range settingturndown 5:1
Damping t0.0 - 120.0 seconds
P
100 %
63 %
0 t 2xt 3xt 4xt 5xt
e.g. damping t = 10 s = 50 s ~100 %
^
LoadR <
U - 12 V
22.5 mA
(Ohm)
Accuracy
Limit point settingDIN 16086
Reference conditionsDIN EN 60770-1
Calibration positionvertical mounting position
Linearity errors< 0.15% of span
TD 5:1 no change
Hysteresis< 0.05% of nominal range
Repeatability< 0.05% of nominal range
Influence of mounting position< 3.5 mbar
Long-term drift< 0.1%/year of nominal range
DIN EN 60770-1
Temperature effect
a)Lower range value / upper range value
in 60°C± 0.15%/10 K of nominal range
in range < 0°C, > 60°C± 0.2%/10 K of nominal range
b) process connection (diaphragm seal) depending on design
flat diaphragmzero point error
DN 25/1"4,8 mbar/10 K
DN 32/1 1/2"2,3 mbar/10 K
DN 401,6 mbar/10 K
DN 50/2"0,6 mbar/10 K
inline diaphragmzero point error
DN 25/1"9,5 mbar/10 K
DN 32/1 1/2"4,1 mbar/10 K
DN 403,9 mbar/10 K
DN 50/2"3,9 mbar/10 K
The specified zero error for the process connection is a guide value for
a standard design. We can provide a detailed system calculation upon
request. Systems with reduced diaphragm seal errors are also available.
P. 2
Data Sheet: D4-017/2
Display module (multifunctional display) optional
pluggable with automatic module detection - plug and measure -
·Module housing made of ABS, encapsulated
electronics unit
·Many operating mode menus
·5-segment pressure read-out with unit
·Read-out display
-pressure (standard)
-percent
-current
-sensor temperature
^
·Bar graph 36 segments = 0...100%
Operator menus
meas. range selection
damping
min-max-value
characteristic
pressure units
measuring circuit test
alarm state
current trimming
pressure trimming
table function
system info
switch points
hysteresis
switching function
·Measuring circuit test (current sensing function)
22.0 mA
·Alarm indicator on display
·Switching function indicator (with switching module)
Switching module, optional
pluggable with automatic module detection - plug and measure -
·No additional auxiliary power required
·Module housing made of ABS, encapsulated
electronics unit
·2 limit values, voltage free, short-circuit-proof
·Switching capacity 50 V DC / 500 mA (Ri < 1.5 Ω)
or 30 V DC / 1.5 A (Ri < 0.3 Ω)
·Overload indicator: LED red, overload or
short-circuit
·Fusible cut-out at overload /short-circuit with
automatic reset
·Switch points: 0.0 - 100.0% adjustable
Standard: 50.0%
·Switching function: maker or breaker, adjustable
Standard: breaker
·Device off circuit: contact open
·Hysteresis: 0.0% to 100.0%, adjustable
standard: 0.1%
falling or rising, adjustable,
standard: falling
·Switching rate: 6 Hz
·Electrically isolated to all sides
Insulation voltage: 500 V, 2.5 kV/2 sec.
·Electrical connection: terminal blocks 1 mm²
Profibus module description and HART
®
connection upon request
P. 3
Data Sheet: D4-017/2
The module selected determines which parameters can be set.
operating menus
zero point
measuring span
damping
min-max-values
characteristic
pressure unit
display of display
module
RANGE / Zero
RANGE / Span
DAMP
HI / LO
FUNC
UNIT
parameter
variability
see instrument ranges
see instrument ranges
120.0 sec.
pressure and temperature
ressetable
linear, table
bar, mbar, kPa, MPa, mmH2O,
mH2O, kg/cm², psi
22 mA
< 3.6 mA, > 21.0 mA
-2 %...+ 5 %
zero point -50...+50%
span -10...+10 % of nom. range
2...31 points in table
software, serial number
revision level
——
function modules
switching display
HART
®
-
20 mAPROFIBUS
modulemodule
module
nominal rangexxxxx
nominal range
0.0 sec.
——
basic module
x
w
——
x
x
x
——
x
——
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
——
linear
bar
——
w
w
——
——
x
——
——
measuring circuit
LOOP
test
alarm state
current trimming
ALARM
I-CAL
——
< 3.6 mA
——
w
——
————
————
pressure trimmingP-CAL
table function
system info
TABLE
INFO
————
x
——
——
0 % = 4 mA
100 % = 20 mA
——
————
——
x
x
x
x
x
x
——
factory data resetRESET
switch points
hysteresis
SWCH1(2)
SWCH1(2)/Hyst.
——————
100.0 % of nominal range
100.0 % of nominal range
50 %
0,1 %
g
breaker
OFF
——
x
w
w
x
——
switching functionSWCH1(2)/SwTypbreaker, maker
write protection
x = configurable
w = factory setting
——
——
ON, OFFx
Connection diagram
Basic module: 4...20 mA
Switching module
P. 4
Data Sheet: D4-017/2
Dimensions/Designs
Housing
(short term up to 140°C, 1h)
Process connections
Mounting position
P. 5
Data Sheet: D4-017/2
Order Details
- please give additional specifications for models not listed -
PASCAL CV for food/pharmaceuticals/biotechnologyCV311 .
explosion · without0
protection
· explosion protection: II 1/2G EEx ia IIC T6
1
0,4 bar
1 bar
4 bar
nominal range
16 bar
40 bar
4 bar abs
16 bar abs
0 to nominal range, unit: bar (Standard)
0 to nominal range, unit: mbar
0 to nominal range, unit:: kPa
0 to nominal range, unit: MPa
measuring
0 to nominal range, unit: mmH2O
range
0 to nominal range, unit: mH2O
0 to nominal range, unit: kg/cm²
0 to nominal range, unit: psi
to... unit ( please fill in details )
adjusted and calibrated from .... to ...., unit ( in details), see below for calibration report
4...20 mA, rising characteristic (standard)
20...4 mA, falling characteristic
4...20 mA with HART function module not yet available
PROFIBUS PAnot yet available
output signal
0.0 sec. (Standard)
damping
120.0 sec.., set to .... ( please fill in )
setting 1)
< 3.6 mA (standard)
alarm state
> 21.0 mA
without
display module
multifunctional display with 5-position digital display and bar graph, pluggable
without switching module
switching module with 2 contacts,
switching capacity 50V DC / 500 mA
switching
pluggable
switching capacity 30V DC / 1.5A
module
standard, s."Techn. description of switching module"
setting 1)
at the factory, specify as required
cable glandPA black (standard)
M 12x1.5brass nickel-plated
electrical
stainless steel
connection
M 12 x1.4 pin
circular plug connector
M 12 x1.8 pin ( required for switching module )
· for process temperature up to 125 °C (short term up to 140 °C), standard
design
· for process temperature up to 160 °C (with temperature decoupler)
process connection
DN
· 25sanitary connection with
groove union nut· 32
· 40according to DIN 11851
flat· 50
· 1"diaphragm seal
clamp connection per ISO 2852
· 1 1/2"
· 2"
· 25
32clamp connection per ·
standardDIN 32676· 40
connection ²· 50
sanitary pipe connection· 25
· 32for pipes per DN 11850
round thread both sides· 40
acc. to DIN 11851· 50
· 25inlineclamp connection according to
DIN 32676, both sides· 32diaphragm seal
· 40for pipes according to DIN 11850
· 50
· 1"clamp connection according to ISO 2852
· 1 1/2"both sides, for pipes according to O.D.
· 2"Tubing "inch"BS 4825 Part 1
· surface, standard
hygienic
· hygienic version¹ (special surface, see data sheet D1-030)
diaphragm
· stainless steel material no. 1.4404, standard
· stainless steel material no. 1.4435
material
other material upon request
· foodstuff oil FD1 (USDA-H1according to FDA) temperature range: -10...+140 °C, standard
system filling
· foodstuff oil FD1 (USDA-H1according to FDA) temperature range: -20...+160 °C, standard
other liquids and temp. ranges upon request
order code (example):
additional features
process connection (diaphragm seal) electropolished
material certificate as per EN 10204-3.1B, wetted parts
inspection certificate as per EN 10204- 3.1B calibration
A1051
A1053
A1056
A1059
A1061
B1056
B1059
F10
F11
F22
F23
F30
F32
F41
F50
F80
F81
H11 . .
H15 . .
H21 . .
H41 . .
0
1
0
1
M1
M2
N10
N4 .
N5 .
0
1
T10
T11
T12
T30
T31
K1085
K2085
DL2100
DL2200
DL2300
DL2400
DL3100
DL3200
DL3300
DL4100
DL4200
DL4300
DL4400
DF1110
DF1120
DF1130
DF1140
DF3110
DF3120
DF3130
DF3140
DF3210
DF3230
DF3240
HY
A4001
A4007
A4009
L22
L23
CV3110A1051F11H1100M2N10T10K1085DL2100
W4035
W1020
W1201
A4001L22
certificate with 5 measuring points
Modifications reserved
P. 6
Data Sheet: D4-017/2
LABOM Mess- und Regeltechnik GmbH
Postfach 12 62 D-27795 Hude
Tel. (04408)804-0 Fax: (00408)804-404
2024年9月6日发(作者:瑞文静)
P
RESSURE
T
RANSMITTER
PASCAL CV
FOR
FOOD
/
PHARMACEUTICALS
/
BIOTECHNOLOGY
T
YPE
S
ERIES
CV 3110
Design Features
■
Modular pressure transmitter with diaphragm seal technology
Signal output::
®
●
4..20 mA, can be retrofitted with optional HART
protocol
●
PROFIBUS PA
■
Function modules
●
Multifunctional display with 5-segment digital display and bar graph
®
●
HART
protocol
●
Switching module with 2 floating channels, maximum 1.5 A
switching current, electrically isolated at all sides, without additional
auxiliary power
■
Function module replacement on site without recalibration
"plug and measure"
■
Watchdog for electronics modules and measuring cell
■
Hygienic design according to EHEDG, FDA und GMP recommendations
■
Material and surface quality according to the hygienic requirements
■
Limits of measuring 80 mbar 40 bar
■
Accuracy: < 0.25% (linearity, hysteresis and repeatability)
■
Turndown 5:1
■
Explosion protection: II 1/2G EEx ia IIC T6
■
Medium temperature up to 160 °C
■
Piezoresistive measuring cell, directly aerated, fully welded
Application
The pressure transmitter PASCAL CV is suited for measuring the relative
and absolute pressures of gases, vapors and liquids. The type series
CV3110 has been developed to meet the stringent demands of food
processing, pharmaceutical technology, and biotechnology. Special attention
has been given to good surface quality. Thus, for instance, roughness
values to Ra 0.4 µm can be guaranteed for wetted parts (for welds: Ra < 0.8
µm) or the system can be electropolished as well.
The modular design of the pressure transmitter allows users to choose the
best possible device for his specific operating requirements.
PASCAL CV is equipped with a variety of process connections and uses
smart module technology for display, switching and communication purposes.
These functional modules can be exchanged or extended with ease without
having to remove the transmitter from the process.
Other designs available
●
PASCAL CV 3100 for general application
●
PASCAL CV 3120 for chemical/petrochemical industry
Basic module
4...20 mA
Function modules
HART
®
-module
Switching
module
Display
module
PROFIBUS
Process connection: all standard screw-in, flange and inline connections
P. 1
Data Sheet: D4-017/2
Rev. 0D3
Instrument ranges
nominal rangeTurndownmeasuring
ranges
measuring spans
min. spanmax. span
overload
limits
vaccum
tight at < 50 °C
0.4 bar - +0.4 bar80 mbar
1 bar -1 ... + 1 bar0.2 bar
4 bar -1 ... + 4 bar0.8 bar
16 bar
5 : 1
-1 ... + 16 bar3.2 bar
40 bar -1 ... + 40 bar8 bar
4 bar abs0 ... 4 bar abs0.8 bar abs
16 bar abs0 ... 16 bar abs3.2 bar abs
limits of measuring range
-100 %
nominal range: e.g. 1 bar
-1bar
Housing design
Housinghygienic housing design with
screw cap and window
Materialhousing:stainless steel . 1.4301
window:Macrolon
gasket:NBR O-ring
Constructiontwo-chamber system, minimum housing
volume, excellent moisture and
condensate protection
Pressure compensationPTFE filter system
Degree of protectionEN 60529, IP 66
Climatic categoryDIN EN 60721 3-4, 4K4H
Electrical connection· screwed terminals 1 mm², cable entry
fitting through screwing
· circular plug connector M 12
Weightstandard device without diaphragm seal
andfunction modules approx. 0.65 kg
Housing design
windows
separate terminal compartment
(reduced volume)
O-ring-
seal
terminals
electronics
fully encapsulated
replaceable
cable entry fitting
gasket
atmospheric pressure
plug connection
compensation
sensor chamber
fully encapsulated
pressure sensor with direct
(reduced volume)
connection to atmospheric
pressure compensation
Process connection
Constructionwelded design
Diaphragmmodifications see page 5 or order code
Materialstainless steel mat.-no. 1.4404 or 1.4435
see order code
Measuring system
Sensorpiezoresistive measuring element
System fillfoodstuff oil FD1 (USDA-H1)
according to FDA
Temperature ranges
Ambient temperature-20 to 85°C
Process temperaturedepending on design
Allowed 85 °C
Note safety values as per examination certificate!
Supply
40 VDC
30 VDC
Approval/tests
Interference emissionEN 50081 section 1
Noise immunityEN 50082 section 2
EU examination certificateII 1/2G EEx ia IIC T6
0.8 bar2 bar400 mbar abs
2 bar7 bar 40 mbar abs
5 bar20 bar 20 mbar abs
17 bar100 bar 20 mbar abs
41 bar100 bar 20 mbar abs
4 bar abs20 bar abs 20 mbar abs
16 bar abs100 bar abs 20 mbar abs
0%
meas. span
100%
0bar
0.2 bar
1 bar
up to 2 bar
Output
20 mA, two-wire,
optional with HART protocol (not yet available)
Current range3.8 - 20.8 mA
Current limitationapprox. 22 mA
Alarm state< 3.6 mA, optional > 21 mA
Delay timeapprox. 160 ms
measuring cycle6 measurements / second
Measuring range settingturndown 5:1
Damping t0.0 - 120.0 seconds
P
100 %
63 %
0 t 2xt 3xt 4xt 5xt
e.g. damping t = 10 s = 50 s ~100 %
^
LoadR <
U - 12 V
22.5 mA
(Ohm)
Accuracy
Limit point settingDIN 16086
Reference conditionsDIN EN 60770-1
Calibration positionvertical mounting position
Linearity errors< 0.15% of span
TD 5:1 no change
Hysteresis< 0.05% of nominal range
Repeatability< 0.05% of nominal range
Influence of mounting position< 3.5 mbar
Long-term drift< 0.1%/year of nominal range
DIN EN 60770-1
Temperature effect
a)Lower range value / upper range value
in 60°C± 0.15%/10 K of nominal range
in range < 0°C, > 60°C± 0.2%/10 K of nominal range
b) process connection (diaphragm seal) depending on design
flat diaphragmzero point error
DN 25/1"4,8 mbar/10 K
DN 32/1 1/2"2,3 mbar/10 K
DN 401,6 mbar/10 K
DN 50/2"0,6 mbar/10 K
inline diaphragmzero point error
DN 25/1"9,5 mbar/10 K
DN 32/1 1/2"4,1 mbar/10 K
DN 403,9 mbar/10 K
DN 50/2"3,9 mbar/10 K
The specified zero error for the process connection is a guide value for
a standard design. We can provide a detailed system calculation upon
request. Systems with reduced diaphragm seal errors are also available.
P. 2
Data Sheet: D4-017/2
Display module (multifunctional display) optional
pluggable with automatic module detection - plug and measure -
·Module housing made of ABS, encapsulated
electronics unit
·Many operating mode menus
·5-segment pressure read-out with unit
·Read-out display
-pressure (standard)
-percent
-current
-sensor temperature
^
·Bar graph 36 segments = 0...100%
Operator menus
meas. range selection
damping
min-max-value
characteristic
pressure units
measuring circuit test
alarm state
current trimming
pressure trimming
table function
system info
switch points
hysteresis
switching function
·Measuring circuit test (current sensing function)
22.0 mA
·Alarm indicator on display
·Switching function indicator (with switching module)
Switching module, optional
pluggable with automatic module detection - plug and measure -
·No additional auxiliary power required
·Module housing made of ABS, encapsulated
electronics unit
·2 limit values, voltage free, short-circuit-proof
·Switching capacity 50 V DC / 500 mA (Ri < 1.5 Ω)
or 30 V DC / 1.5 A (Ri < 0.3 Ω)
·Overload indicator: LED red, overload or
short-circuit
·Fusible cut-out at overload /short-circuit with
automatic reset
·Switch points: 0.0 - 100.0% adjustable
Standard: 50.0%
·Switching function: maker or breaker, adjustable
Standard: breaker
·Device off circuit: contact open
·Hysteresis: 0.0% to 100.0%, adjustable
standard: 0.1%
falling or rising, adjustable,
standard: falling
·Switching rate: 6 Hz
·Electrically isolated to all sides
Insulation voltage: 500 V, 2.5 kV/2 sec.
·Electrical connection: terminal blocks 1 mm²
Profibus module description and HART
®
connection upon request
P. 3
Data Sheet: D4-017/2
The module selected determines which parameters can be set.
operating menus
zero point
measuring span
damping
min-max-values
characteristic
pressure unit
display of display
module
RANGE / Zero
RANGE / Span
DAMP
HI / LO
FUNC
UNIT
parameter
variability
see instrument ranges
see instrument ranges
120.0 sec.
pressure and temperature
ressetable
linear, table
bar, mbar, kPa, MPa, mmH2O,
mH2O, kg/cm², psi
22 mA
< 3.6 mA, > 21.0 mA
-2 %...+ 5 %
zero point -50...+50%
span -10...+10 % of nom. range
2...31 points in table
software, serial number
revision level
——
function modules
switching display
HART
®
-
20 mAPROFIBUS
modulemodule
module
nominal rangexxxxx
nominal range
0.0 sec.
——
basic module
x
w
——
x
x
x
——
x
——
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
——
linear
bar
——
w
w
——
——
x
——
——
measuring circuit
LOOP
test
alarm state
current trimming
ALARM
I-CAL
——
< 3.6 mA
——
w
——
————
————
pressure trimmingP-CAL
table function
system info
TABLE
INFO
————
x
——
——
0 % = 4 mA
100 % = 20 mA
——
————
——
x
x
x
x
x
x
——
factory data resetRESET
switch points
hysteresis
SWCH1(2)
SWCH1(2)/Hyst.
——————
100.0 % of nominal range
100.0 % of nominal range
50 %
0,1 %
g
breaker
OFF
——
x
w
w
x
——
switching functionSWCH1(2)/SwTypbreaker, maker
write protection
x = configurable
w = factory setting
——
——
ON, OFFx
Connection diagram
Basic module: 4...20 mA
Switching module
P. 4
Data Sheet: D4-017/2
Dimensions/Designs
Housing
(short term up to 140°C, 1h)
Process connections
Mounting position
P. 5
Data Sheet: D4-017/2
Order Details
- please give additional specifications for models not listed -
PASCAL CV for food/pharmaceuticals/biotechnologyCV311 .
explosion · without0
protection
· explosion protection: II 1/2G EEx ia IIC T6
1
0,4 bar
1 bar
4 bar
nominal range
16 bar
40 bar
4 bar abs
16 bar abs
0 to nominal range, unit: bar (Standard)
0 to nominal range, unit: mbar
0 to nominal range, unit:: kPa
0 to nominal range, unit: MPa
measuring
0 to nominal range, unit: mmH2O
range
0 to nominal range, unit: mH2O
0 to nominal range, unit: kg/cm²
0 to nominal range, unit: psi
to... unit ( please fill in details )
adjusted and calibrated from .... to ...., unit ( in details), see below for calibration report
4...20 mA, rising characteristic (standard)
20...4 mA, falling characteristic
4...20 mA with HART function module not yet available
PROFIBUS PAnot yet available
output signal
0.0 sec. (Standard)
damping
120.0 sec.., set to .... ( please fill in )
setting 1)
< 3.6 mA (standard)
alarm state
> 21.0 mA
without
display module
multifunctional display with 5-position digital display and bar graph, pluggable
without switching module
switching module with 2 contacts,
switching capacity 50V DC / 500 mA
switching
pluggable
switching capacity 30V DC / 1.5A
module
standard, s."Techn. description of switching module"
setting 1)
at the factory, specify as required
cable glandPA black (standard)
M 12x1.5brass nickel-plated
electrical
stainless steel
connection
M 12 x1.4 pin
circular plug connector
M 12 x1.8 pin ( required for switching module )
· for process temperature up to 125 °C (short term up to 140 °C), standard
design
· for process temperature up to 160 °C (with temperature decoupler)
process connection
DN
· 25sanitary connection with
groove union nut· 32
· 40according to DIN 11851
flat· 50
· 1"diaphragm seal
clamp connection per ISO 2852
· 1 1/2"
· 2"
· 25
32clamp connection per ·
standardDIN 32676· 40
connection ²· 50
sanitary pipe connection· 25
· 32for pipes per DN 11850
round thread both sides· 40
acc. to DIN 11851· 50
· 25inlineclamp connection according to
DIN 32676, both sides· 32diaphragm seal
· 40for pipes according to DIN 11850
· 50
· 1"clamp connection according to ISO 2852
· 1 1/2"both sides, for pipes according to O.D.
· 2"Tubing "inch"BS 4825 Part 1
· surface, standard
hygienic
· hygienic version¹ (special surface, see data sheet D1-030)
diaphragm
· stainless steel material no. 1.4404, standard
· stainless steel material no. 1.4435
material
other material upon request
· foodstuff oil FD1 (USDA-H1according to FDA) temperature range: -10...+140 °C, standard
system filling
· foodstuff oil FD1 (USDA-H1according to FDA) temperature range: -20...+160 °C, standard
other liquids and temp. ranges upon request
order code (example):
additional features
process connection (diaphragm seal) electropolished
material certificate as per EN 10204-3.1B, wetted parts
inspection certificate as per EN 10204- 3.1B calibration
A1051
A1053
A1056
A1059
A1061
B1056
B1059
F10
F11
F22
F23
F30
F32
F41
F50
F80
F81
H11 . .
H15 . .
H21 . .
H41 . .
0
1
0
1
M1
M2
N10
N4 .
N5 .
0
1
T10
T11
T12
T30
T31
K1085
K2085
DL2100
DL2200
DL2300
DL2400
DL3100
DL3200
DL3300
DL4100
DL4200
DL4300
DL4400
DF1110
DF1120
DF1130
DF1140
DF3110
DF3120
DF3130
DF3140
DF3210
DF3230
DF3240
HY
A4001
A4007
A4009
L22
L23
CV3110A1051F11H1100M2N10T10K1085DL2100
W4035
W1020
W1201
A4001L22
certificate with 5 measuring points
Modifications reserved
P. 6
Data Sheet: D4-017/2
LABOM Mess- und Regeltechnik GmbH
Postfach 12 62 D-27795 Hude
Tel. (04408)804-0 Fax: (00408)804-404