最新消息: USBMI致力于为网友们分享Windows、安卓、IOS等主流手机系统相关的资讯以及评测、同时提供相关教程、应用、软件下载等服务。

TRT037N 无线七天可编程室内温度控制器说明书

IT圈 admin 23浏览 0评论

2024年10月18日发(作者:徐梓颖)

TRT037N

Wireless 7 Day

Programmable

Room Thermostat

Cat. No. TRT037

Transmitter

Receiver

Operating & Installation Instructions

What is a programmable room thermostat?

... an explanation for householders

A programmable room thermostat is both a programmer and a

18oC, and then turn them up by one degree each day

until you are com-

room thermostat. A programmer allows you to set ‘On’ and fortable with the temperatures. You won’t have to adjust the

‘Off’ time periods to suit your own lifestyle. A room thermostat thermostat further. Any adjustments above these

works by sensing the air temperature, switching on the heating settings will waste energy and cost you more money.

when the air temperature falls below the thermostat setting,

and switching it off once this set temperature has been reached.

If your heating system is a boiler with radiators, there will

So, a programmable room thermostat lets you choose what

usually be only one programmable room thermostat to control

times you want the heating to be on, and what temperature it

the whole house. But you can have different temperatures in

should reach while it is on. It will allow you to select different

individual rooms by installing thermostatic radiator valves (TRVs)

temperatures in your home at different times of the day (and

on individual radiators. If you don’t have TRVs, you should

days of the week) to meet your particular needs.

choose a temperature that is reasonable for the whole house.

If you do have TRVs, you can choose a slightly higher setting to

Turning a programmable room thermostat to a higher setting

make sure that even the coldest room is comfortable, then

will not make the room heat up any faster. How quickly the

prevent any overheating in other rooms by adjusting the TRVs.

room heats up depends on the design of the heating system, for

example, the size of boiler and radiators.

The time on the programmer must be correct. Some types have

to be adjusted in spring and autumn at the changes between

Neither does the setting affect how quickly the room cools

Greenwich Mean Time and British Summer Time.

down. Turning a programmable room thermostat to a lower

setting will result in the room being controlled at a lower

You may be able to temporarily adjust the heating programme,

temperature, and saves energy.

for example, ‘Override’, ‘Advance’ or ‘Boost’. These are

explained in the manufacturer’s instructions.

The way to set and use your programmable room ther-

mostat is to find the lowest temperature settings that

Programmable room thermostats need a free flow of air

you are comfortable with at the different times you

to sense the temperature, so they must not be

have chosen, and then leave it alone to do its job. The

covered by curtains or blocked by furniture. Nearby

best way to do this is to set low temperatures first,

electric fires, televisions, wall or table lamps may

say

prevent the thermostat from working properly.

1. Introduction

TRT products are a cost effective

comprehensive range of thermostats and

controllers designed for internal use only.

The TRT037 is a battery powered wireless

electronic programmable room thermostat,

with 6 different temperature periods per day,

automatic summer/winter time changeover, 5

day plus 2 or individual (7) day programming,

and a frost mode. There is also the option of

optimum start and adjustable span, from 1ºC

to 0.5ºC.

The TRT037 comes in two parts - a thermostat/

transmitter which is battery powered and

totally wire-free as well as a receiver which

connects into the heating system. This eases

the installation in two ways - there is no need

to bury cable runs to the thermostat/

transmitter and the receiver can be mounted

close to the boiler and other system components.

The two parts are designed to be surface

mounted on their supplied wall plates.

The electrical supply must be isolated before

attempting to install the receiver unit.

TRT037 Wireless Programmable

Room Thermostat/Transmitter

Day of

Time of day

Room temperature

Selects

week

(programme

display

current set

time during

(set temperature

temperature

setting)

displayed flashing

and changes

during setting)

date, time and

temperature

Flashing

Temperature

Operates

when frost

override

frost

protection

protection

is on

Shows when

Flashing symbol,

heat is

battery change

demanded

required

Fig. 1

TRT037 Wireless Programmable

Room Thermostat/Transmitter

Button and Border

Selects time, temperature

screen illuminates

or date to be changed and

illuminate when +/- buttons

is used with button to

when pressed are pressed

enable communication

and for 5 seconds and for 5 seconds

between the transmitter

after releaseafter release

and receiver

AM PM

SET ROOM TEMP

select

set

reset

Initiates programme

setting sequence and in

conjunction with the select

Reset

Programme

button initiates time and

button

access flap

date setting sequence

Fig. 1a

TRT037 Receiver Front View

Learn/manual

light

A/M

Automatic/

Learn button

Manual

enabling

Learn

mode

communication

button

between the

transmitter

and receiver

Output

also controlling

on light

output in

manual

Fig. 2

TRT037 Transmitter Rear View

Optimum start

Span Program

jumper

jumperjumper

ON OFFOst0.5 1.0SPAN5-2 7PROGRAM

Wall plate retaining screws

Fig. 3

(at bottom of TRT037)

Receiver Back Plate Removed

Retaining tab

COMNCNONL

Terminal for

Alternative

maintaining

fixing holes

continuity of

earth

Fig. 4

Mount the wall plate in this configuration only

Transmitter Back Plate Removed

Alternative

Retaining tab

fixing holes

Alternative

fixing holes

Fig. 5

Mount the wall plate in this configuration only

Battery Holder Removal

Lever battery holder outwards using a

large flat bladed screwdriver (shown) or a

large coin.

Left hand

side of TRT037

Fig. 6

Battery holder

Contents

TRT037 thermostat

2 x AA batteries

TRT037 wall plate

TRT037 receiver

TRT037 instruction leaflet

TRT037 receiver wall

4 x wall plugs

plate

4 x screws

2. Siting

The TRT037 transmitter must be sited where it

would not be influenced by heat sources, for

example, above a radiator or television or

refrigerator/freezer, or in direct sunlight or

subject to draughts. The product requires air

circulation, so do not position above or below

shelving or other wall mounted obstacles.

It should be mounted approximately 1.5m

above floor level.

The TRT037 receiver should be mounted close

to the items it will be boiler,

control valves and pump. It should be mounted

in a position where its control buttons and

indicator lights can be easily accessed.

3. Installation

This product must be installed in accordance with

the appropriate building and wiring regulations.

In all cases if there is a doubt as to how to

proceed with an installation consult a qualified

electrician, your local authority’s building

control department or the Timeguard helpline

************).

The TRT037 transmitter and receiver are

designed to be surface mounted on their

supplied wall plates.

Always isolate the mains supply before

removing the receiver from its wall plate.

Transmitter

Lever the battery holder out using a large flat

blade screwdriver or large coin (see Fig. 6) and

then pull out fully.

Insert the 2 x AA alkaline batteries supplied into

the battery holder maintaining the correct polarity

as shown in the base of the battery holder.

Push the battery holder back into place until it

clicks shut.

Remove wall plate from unit, by undoing

retaining screws (see Fig. 5), and pivoting the

bottom of the wall plate outwards. The TRT037

transmitter can then be lifted off.

Fix wall plate securely to the wall, using screws

(and wall plugs if necessary) provided. The screws

which secure the TRT037 transmitter to the wall

plate should point downwards.

To reinstall the unit on the wall plate first ensure

the wall plate retaining screws are loosened

enough to clear the TRT037 transmitter body then

engage the top of the TRT037 transmitter onto

the wall plate retaining tabs (see Fig. 5), and push

firmly downwards and then inwards. Once in

place, secure with the retaining screws.

Receiver

Isolate 230VAC mains supply. Incoming and outgoing

wires should be 1.5 sq mm.

Remove wall plate from unit, by undoing retaining

screws (see Fig. 4), and pivoting the bottom of the

wall plate outwards. The TRT037 receiver can then

be lifted off.

Thread the incoming wires through the hole in the

wall plate, and fix wall plate securely to the wall,

using screws (and wall plugs if necessary) provided.

The screws which secure the TRT037 receiver to

the wall plate should point downwards.

Allow sufficient excess cable to wire up the unit,

but not too much to make it difficult to close the

unit onto the wall plate.

Connect the conductors to the relevant terminals,

according to the wiring diagram below (Fig. 7).

Ensure that the curved brass washers grip the

conductors.

Receiver Wiring Diagram

COMNCNONL

Fig. 7

NL

This unit is double insulated, and hence does

not need connection to the earth. If earth

continuity is required, please use the earth

terminal on the wall plate, (see Fig. 4).

To reinstall the unit on the wall plate first ensure

the wall plate retaining screws are loosened

enough to clear the TRT037 receiver body then

engage the top of the TRT037 receiver onto the

wall plate retaining tabs (see Fig. 4), and push

firmly downwards and then inwards. There will

be some resistance from the terminals. Once in

place, secure with the retaining screws.

Finally check that the system wiring is complete

and correct.

4. Operation

Initially it is important to get the two parts

(transmitter and receiver) talking to each other.

This is best carried out by two people, one at each

of the separate locations.

Press reset on the transmitter and at the receiver

connect the mains supply to the unit. Both indicator

lights (learn/manual and output on the receiver) will

come on for around 3 seconds and then go out. Press

and hold the learn button on the receiver for around

10 seconds until the blue learn/manual light starts

flashing.

At the transmitter press and hold the select and

buttons until the flashing blue learn/manual light on

the receiver goes out. The transmitter and receiver

are now communicating. This can be confirmed by

carrying out the following:- at the transmitter press

the + button until the set temperature (identified by

momentarily pressing the + or - button) is higher

than the room temperature (normally displayed).

After a short delay the output on light on the

receiver comes on.

Now press the - button at the transmitter until the

set temperature is lower than the room temperature

and after a short delay the output light will turn off.

This proves the communication is fully functional.

There is a manual facility available at the receiver.

If the auto/manual (A/M) button is pressed the blue

learn/manual light will come on indicating the receiv-

er is in manual mode. The receiver output can now

be turned on and off using the learn button.

Programming

Decide whether weekday/weekend (5-2) or individual

(7) day programming is required and move the

appropriate jumper on the rear of the TRT037

transmitter.

The temperature span (difference between on and

off temperatures) can be adjusted between 1ºC and

0.5ºC using a jumper found on the rear of the unit.

Optimum start (switching on earlier on colder

mornings) can also be turned on or off using a

jumper on the rear of the unit.

It is important to make these decisions first,

as after any change of jumper position, reset needs

to be pressed, which will return the unit to default

time and programme.

Pressing any button illuminates the screen

automatically.

During time/date and programme setting if a button

is not pressed within 15 seconds the display will

revert to the start of the sequence.

Setting date and time of day

Open programme access flap and press reset, using a

pen or similar object. All of the screen segments will

show briefly, and then the current room temperature

will be displayed.

To programme the date and time of day, open

programme access flap, and simultaneously press

and hold both the select and set buttons for 3

seconds. The year will flash.

Use the + and - button to set the correct year.

Press select to move on to programming the month

(shown to the left), and then again to programme

the day. Press select again to

programme the hours (am/pm), and again to

programme the minutes (each time using the

+/- button to make the change). Press set to return

to operating mode.

If at any time a button is not pressed for 15

seconds, the unit will return to operating mode.

Programming temperature periods for

7 days option

Notes

1) There are no off periods with this controller.

The programming sequence is:-

Start time, temperature, second start time,

second temperature and so on. Setting

temperature to 10ºC is as close to off as can be

achieved (and for most situations will be off

unless the weather is very cold).

2) If you do not want a higher temperature period

in the middle of the day adjust the temperature

for this period downward to match those of the

proceeding and subsequent period temperatures.

3) The TRT037 comes with a factory installed

(default) programme for both 5-2 and 7 day

options which you use or modify as you wish. Just

pressing the reset button brings this programme

into operation.

The default programme for every day is as

follows:-

6:00 AM 21ºC

8:00 AM 17ºC

12:00 PM 21ºC

2:00 PM 17ºC

4:00 PM 21ºC

10:00 PM 17ºC

For both 5-2 and 7 day options.

To programme the temperature periods, press

the set button. Mon will flash. To programme

Mondays time/temperature periods press select but-

ton. Alternatively use the + and - buttons to change

the day, and then select to continue. The time will

then flash. This is the start time for the first period.

Press + or - to set the hour for the start time for

period 1. Press select to move to the minutes. Use

the + and - to set the minutes. Press select to set the

temperature for this period. Use the + or - keys to

set the desired temperature. Press select again to

programme the next time period. There are

6 time periods per day.

Once the 6 periods for Monday are

programmed, Press set button, and Monday

will start to flash. Use the + and - button to change

the day to Tuesday, and then use select to program

Tuesdays time periods and

temperatures. For 7 day programming, this will need

to be done for all 7 days. If set is pressed twice, the

unit will return to operating mode.

Omitting Days

Omitting a day can be achieved by selecting 10ºC for

every time period for that day (all times and temper-

atures must be entered).

The heating will not turn on unless the room

temperature falls below 10ºC (50ºF).

Programming temperature periods for 5-2 days

option

For 5-2 day mode, time periods and

temperatures will need to be programmed for M-F

and then for S-S. ie: only 2 sets of times need to be

programmed, not 7 (individual) sets of times.

Temperature override

In operating mode, the temperature set for the

current period can be overridden. To adjust the set

temperature, press the + or - button once. The

screen will illuminate blue while button is pressed.

Use + and - buttons to set desired temperature. If

the + or - button is held down, the display will

advance rapidly. Once the desired temperature is

set, the unit should revert to displaying the current

room temperature 5 seconds after the last button

press. The illumination will also turn off after 5

seconds. In manual mode, there will be a hand

symbol displayed on the screen. The new

temperature will remain valid until the next

programmed period starts.

A burner symbol is displayed when temperature

is below desired value, indicating that the

thermostat is calling for heat from the boiler.

Review set temperature

The set temperature can be reviewed at any time,

by a single press of the + or - button. 5 seconds after

this single button push, the unit will show the

current room temperature, and the screen

illumination will turn off.

Frost protection

Frost protection reduces the set temperature to 5ºC.

Frost protection is activated by holding down the

frost protection button for 3 seconds. When in frost

mode, the frost symbol will flash on the display.

The set temperature buttons remain non-functional

during frost mode. The unit will remain in frost

mode until the frost button is held down for a

further 3 seconds.

Battery replacement

When the battery needs replacing, a battery symbol

will flash on the display.

Sleep mode

The unit can be put into sleep mode by simultaneously

holding down the + and - buttons for 3 seconds.

Pressing any button will exit sleep mode. In sleep

mode, all outputs are suspended and the screen is

blank (useful for longer periods when the house is

unoccupied and frost protection is not required).

To clean use a dry cloth only. Do not use any

liquid cleaners.

5. Specifications

Current rating: 3 (1) A

Voltage: 230V, 50Hz

Switch type: Single pole, change-over (SPCO)

Operating

temperature

range: 0ºC to 50ºC

Set temperature

range: 10ºC to 35ºC adjustable in

0.5ºC steps

Complies with: BS EN 60730

Conforms to

directives: 73-23-EEC, 89-336-EEC

Span: 1ºC or 0.5ºC

Micro

disconnection: Type 1.B control action

Batteries: 2 x AA alkaline

For assistance with the product please contact:-

HELPLINE

020-8450-0515

*****************************

3 Year Guarantee

In the unlikely event of this product becoming

faulty due to defective material or manufacture

within 3 years of the date of purchase, please

return it to your supplier in the first year with proof

of purchase and it will be replaced free of charge.

For years 2 and 3 or any difficulty in the first year

telephone the helpline on

***********.

For a product brochure please contact:

Timeguard Ltd. Victory Park, 400 Edgware Road,

London NW2 6ND Tel: 020-8452-1112

************************

A Group company

67-058-328

TRT037N

2024年10月18日发(作者:徐梓颖)

TRT037N

Wireless 7 Day

Programmable

Room Thermostat

Cat. No. TRT037

Transmitter

Receiver

Operating & Installation Instructions

What is a programmable room thermostat?

... an explanation for householders

A programmable room thermostat is both a programmer and a

18oC, and then turn them up by one degree each day

until you are com-

room thermostat. A programmer allows you to set ‘On’ and fortable with the temperatures. You won’t have to adjust the

‘Off’ time periods to suit your own lifestyle. A room thermostat thermostat further. Any adjustments above these

works by sensing the air temperature, switching on the heating settings will waste energy and cost you more money.

when the air temperature falls below the thermostat setting,

and switching it off once this set temperature has been reached.

If your heating system is a boiler with radiators, there will

So, a programmable room thermostat lets you choose what

usually be only one programmable room thermostat to control

times you want the heating to be on, and what temperature it

the whole house. But you can have different temperatures in

should reach while it is on. It will allow you to select different

individual rooms by installing thermostatic radiator valves (TRVs)

temperatures in your home at different times of the day (and

on individual radiators. If you don’t have TRVs, you should

days of the week) to meet your particular needs.

choose a temperature that is reasonable for the whole house.

If you do have TRVs, you can choose a slightly higher setting to

Turning a programmable room thermostat to a higher setting

make sure that even the coldest room is comfortable, then

will not make the room heat up any faster. How quickly the

prevent any overheating in other rooms by adjusting the TRVs.

room heats up depends on the design of the heating system, for

example, the size of boiler and radiators.

The time on the programmer must be correct. Some types have

to be adjusted in spring and autumn at the changes between

Neither does the setting affect how quickly the room cools

Greenwich Mean Time and British Summer Time.

down. Turning a programmable room thermostat to a lower

setting will result in the room being controlled at a lower

You may be able to temporarily adjust the heating programme,

temperature, and saves energy.

for example, ‘Override’, ‘Advance’ or ‘Boost’. These are

explained in the manufacturer’s instructions.

The way to set and use your programmable room ther-

mostat is to find the lowest temperature settings that

Programmable room thermostats need a free flow of air

you are comfortable with at the different times you

to sense the temperature, so they must not be

have chosen, and then leave it alone to do its job. The

covered by curtains or blocked by furniture. Nearby

best way to do this is to set low temperatures first,

electric fires, televisions, wall or table lamps may

say

prevent the thermostat from working properly.

1. Introduction

TRT products are a cost effective

comprehensive range of thermostats and

controllers designed for internal use only.

The TRT037 is a battery powered wireless

electronic programmable room thermostat,

with 6 different temperature periods per day,

automatic summer/winter time changeover, 5

day plus 2 or individual (7) day programming,

and a frost mode. There is also the option of

optimum start and adjustable span, from 1ºC

to 0.5ºC.

The TRT037 comes in two parts - a thermostat/

transmitter which is battery powered and

totally wire-free as well as a receiver which

connects into the heating system. This eases

the installation in two ways - there is no need

to bury cable runs to the thermostat/

transmitter and the receiver can be mounted

close to the boiler and other system components.

The two parts are designed to be surface

mounted on their supplied wall plates.

The electrical supply must be isolated before

attempting to install the receiver unit.

TRT037 Wireless Programmable

Room Thermostat/Transmitter

Day of

Time of day

Room temperature

Selects

week

(programme

display

current set

time during

(set temperature

temperature

setting)

displayed flashing

and changes

during setting)

date, time and

temperature

Flashing

Temperature

Operates

when frost

override

frost

protection

protection

is on

Shows when

Flashing symbol,

heat is

battery change

demanded

required

Fig. 1

TRT037 Wireless Programmable

Room Thermostat/Transmitter

Button and Border

Selects time, temperature

screen illuminates

or date to be changed and

illuminate when +/- buttons

is used with button to

when pressed are pressed

enable communication

and for 5 seconds and for 5 seconds

between the transmitter

after releaseafter release

and receiver

AM PM

SET ROOM TEMP

select

set

reset

Initiates programme

setting sequence and in

conjunction with the select

Reset

Programme

button initiates time and

button

access flap

date setting sequence

Fig. 1a

TRT037 Receiver Front View

Learn/manual

light

A/M

Automatic/

Learn button

Manual

enabling

Learn

mode

communication

button

between the

transmitter

and receiver

Output

also controlling

on light

output in

manual

Fig. 2

TRT037 Transmitter Rear View

Optimum start

Span Program

jumper

jumperjumper

ON OFFOst0.5 1.0SPAN5-2 7PROGRAM

Wall plate retaining screws

Fig. 3

(at bottom of TRT037)

Receiver Back Plate Removed

Retaining tab

COMNCNONL

Terminal for

Alternative

maintaining

fixing holes

continuity of

earth

Fig. 4

Mount the wall plate in this configuration only

Transmitter Back Plate Removed

Alternative

Retaining tab

fixing holes

Alternative

fixing holes

Fig. 5

Mount the wall plate in this configuration only

Battery Holder Removal

Lever battery holder outwards using a

large flat bladed screwdriver (shown) or a

large coin.

Left hand

side of TRT037

Fig. 6

Battery holder

Contents

TRT037 thermostat

2 x AA batteries

TRT037 wall plate

TRT037 receiver

TRT037 instruction leaflet

TRT037 receiver wall

4 x wall plugs

plate

4 x screws

2. Siting

The TRT037 transmitter must be sited where it

would not be influenced by heat sources, for

example, above a radiator or television or

refrigerator/freezer, or in direct sunlight or

subject to draughts. The product requires air

circulation, so do not position above or below

shelving or other wall mounted obstacles.

It should be mounted approximately 1.5m

above floor level.

The TRT037 receiver should be mounted close

to the items it will be boiler,

control valves and pump. It should be mounted

in a position where its control buttons and

indicator lights can be easily accessed.

3. Installation

This product must be installed in accordance with

the appropriate building and wiring regulations.

In all cases if there is a doubt as to how to

proceed with an installation consult a qualified

electrician, your local authority’s building

control department or the Timeguard helpline

************).

The TRT037 transmitter and receiver are

designed to be surface mounted on their

supplied wall plates.

Always isolate the mains supply before

removing the receiver from its wall plate.

Transmitter

Lever the battery holder out using a large flat

blade screwdriver or large coin (see Fig. 6) and

then pull out fully.

Insert the 2 x AA alkaline batteries supplied into

the battery holder maintaining the correct polarity

as shown in the base of the battery holder.

Push the battery holder back into place until it

clicks shut.

Remove wall plate from unit, by undoing

retaining screws (see Fig. 5), and pivoting the

bottom of the wall plate outwards. The TRT037

transmitter can then be lifted off.

Fix wall plate securely to the wall, using screws

(and wall plugs if necessary) provided. The screws

which secure the TRT037 transmitter to the wall

plate should point downwards.

To reinstall the unit on the wall plate first ensure

the wall plate retaining screws are loosened

enough to clear the TRT037 transmitter body then

engage the top of the TRT037 transmitter onto

the wall plate retaining tabs (see Fig. 5), and push

firmly downwards and then inwards. Once in

place, secure with the retaining screws.

Receiver

Isolate 230VAC mains supply. Incoming and outgoing

wires should be 1.5 sq mm.

Remove wall plate from unit, by undoing retaining

screws (see Fig. 4), and pivoting the bottom of the

wall plate outwards. The TRT037 receiver can then

be lifted off.

Thread the incoming wires through the hole in the

wall plate, and fix wall plate securely to the wall,

using screws (and wall plugs if necessary) provided.

The screws which secure the TRT037 receiver to

the wall plate should point downwards.

Allow sufficient excess cable to wire up the unit,

but not too much to make it difficult to close the

unit onto the wall plate.

Connect the conductors to the relevant terminals,

according to the wiring diagram below (Fig. 7).

Ensure that the curved brass washers grip the

conductors.

Receiver Wiring Diagram

COMNCNONL

Fig. 7

NL

This unit is double insulated, and hence does

not need connection to the earth. If earth

continuity is required, please use the earth

terminal on the wall plate, (see Fig. 4).

To reinstall the unit on the wall plate first ensure

the wall plate retaining screws are loosened

enough to clear the TRT037 receiver body then

engage the top of the TRT037 receiver onto the

wall plate retaining tabs (see Fig. 4), and push

firmly downwards and then inwards. There will

be some resistance from the terminals. Once in

place, secure with the retaining screws.

Finally check that the system wiring is complete

and correct.

4. Operation

Initially it is important to get the two parts

(transmitter and receiver) talking to each other.

This is best carried out by two people, one at each

of the separate locations.

Press reset on the transmitter and at the receiver

connect the mains supply to the unit. Both indicator

lights (learn/manual and output on the receiver) will

come on for around 3 seconds and then go out. Press

and hold the learn button on the receiver for around

10 seconds until the blue learn/manual light starts

flashing.

At the transmitter press and hold the select and

buttons until the flashing blue learn/manual light on

the receiver goes out. The transmitter and receiver

are now communicating. This can be confirmed by

carrying out the following:- at the transmitter press

the + button until the set temperature (identified by

momentarily pressing the + or - button) is higher

than the room temperature (normally displayed).

After a short delay the output on light on the

receiver comes on.

Now press the - button at the transmitter until the

set temperature is lower than the room temperature

and after a short delay the output light will turn off.

This proves the communication is fully functional.

There is a manual facility available at the receiver.

If the auto/manual (A/M) button is pressed the blue

learn/manual light will come on indicating the receiv-

er is in manual mode. The receiver output can now

be turned on and off using the learn button.

Programming

Decide whether weekday/weekend (5-2) or individual

(7) day programming is required and move the

appropriate jumper on the rear of the TRT037

transmitter.

The temperature span (difference between on and

off temperatures) can be adjusted between 1ºC and

0.5ºC using a jumper found on the rear of the unit.

Optimum start (switching on earlier on colder

mornings) can also be turned on or off using a

jumper on the rear of the unit.

It is important to make these decisions first,

as after any change of jumper position, reset needs

to be pressed, which will return the unit to default

time and programme.

Pressing any button illuminates the screen

automatically.

During time/date and programme setting if a button

is not pressed within 15 seconds the display will

revert to the start of the sequence.

Setting date and time of day

Open programme access flap and press reset, using a

pen or similar object. All of the screen segments will

show briefly, and then the current room temperature

will be displayed.

To programme the date and time of day, open

programme access flap, and simultaneously press

and hold both the select and set buttons for 3

seconds. The year will flash.

Use the + and - button to set the correct year.

Press select to move on to programming the month

(shown to the left), and then again to programme

the day. Press select again to

programme the hours (am/pm), and again to

programme the minutes (each time using the

+/- button to make the change). Press set to return

to operating mode.

If at any time a button is not pressed for 15

seconds, the unit will return to operating mode.

Programming temperature periods for

7 days option

Notes

1) There are no off periods with this controller.

The programming sequence is:-

Start time, temperature, second start time,

second temperature and so on. Setting

temperature to 10ºC is as close to off as can be

achieved (and for most situations will be off

unless the weather is very cold).

2) If you do not want a higher temperature period

in the middle of the day adjust the temperature

for this period downward to match those of the

proceeding and subsequent period temperatures.

3) The TRT037 comes with a factory installed

(default) programme for both 5-2 and 7 day

options which you use or modify as you wish. Just

pressing the reset button brings this programme

into operation.

The default programme for every day is as

follows:-

6:00 AM 21ºC

8:00 AM 17ºC

12:00 PM 21ºC

2:00 PM 17ºC

4:00 PM 21ºC

10:00 PM 17ºC

For both 5-2 and 7 day options.

To programme the temperature periods, press

the set button. Mon will flash. To programme

Mondays time/temperature periods press select but-

ton. Alternatively use the + and - buttons to change

the day, and then select to continue. The time will

then flash. This is the start time for the first period.

Press + or - to set the hour for the start time for

period 1. Press select to move to the minutes. Use

the + and - to set the minutes. Press select to set the

temperature for this period. Use the + or - keys to

set the desired temperature. Press select again to

programme the next time period. There are

6 time periods per day.

Once the 6 periods for Monday are

programmed, Press set button, and Monday

will start to flash. Use the + and - button to change

the day to Tuesday, and then use select to program

Tuesdays time periods and

temperatures. For 7 day programming, this will need

to be done for all 7 days. If set is pressed twice, the

unit will return to operating mode.

Omitting Days

Omitting a day can be achieved by selecting 10ºC for

every time period for that day (all times and temper-

atures must be entered).

The heating will not turn on unless the room

temperature falls below 10ºC (50ºF).

Programming temperature periods for 5-2 days

option

For 5-2 day mode, time periods and

temperatures will need to be programmed for M-F

and then for S-S. ie: only 2 sets of times need to be

programmed, not 7 (individual) sets of times.

Temperature override

In operating mode, the temperature set for the

current period can be overridden. To adjust the set

temperature, press the + or - button once. The

screen will illuminate blue while button is pressed.

Use + and - buttons to set desired temperature. If

the + or - button is held down, the display will

advance rapidly. Once the desired temperature is

set, the unit should revert to displaying the current

room temperature 5 seconds after the last button

press. The illumination will also turn off after 5

seconds. In manual mode, there will be a hand

symbol displayed on the screen. The new

temperature will remain valid until the next

programmed period starts.

A burner symbol is displayed when temperature

is below desired value, indicating that the

thermostat is calling for heat from the boiler.

Review set temperature

The set temperature can be reviewed at any time,

by a single press of the + or - button. 5 seconds after

this single button push, the unit will show the

current room temperature, and the screen

illumination will turn off.

Frost protection

Frost protection reduces the set temperature to 5ºC.

Frost protection is activated by holding down the

frost protection button for 3 seconds. When in frost

mode, the frost symbol will flash on the display.

The set temperature buttons remain non-functional

during frost mode. The unit will remain in frost

mode until the frost button is held down for a

further 3 seconds.

Battery replacement

When the battery needs replacing, a battery symbol

will flash on the display.

Sleep mode

The unit can be put into sleep mode by simultaneously

holding down the + and - buttons for 3 seconds.

Pressing any button will exit sleep mode. In sleep

mode, all outputs are suspended and the screen is

blank (useful for longer periods when the house is

unoccupied and frost protection is not required).

To clean use a dry cloth only. Do not use any

liquid cleaners.

5. Specifications

Current rating: 3 (1) A

Voltage: 230V, 50Hz

Switch type: Single pole, change-over (SPCO)

Operating

temperature

range: 0ºC to 50ºC

Set temperature

range: 10ºC to 35ºC adjustable in

0.5ºC steps

Complies with: BS EN 60730

Conforms to

directives: 73-23-EEC, 89-336-EEC

Span: 1ºC or 0.5ºC

Micro

disconnection: Type 1.B control action

Batteries: 2 x AA alkaline

For assistance with the product please contact:-

HELPLINE

020-8450-0515

*****************************

3 Year Guarantee

In the unlikely event of this product becoming

faulty due to defective material or manufacture

within 3 years of the date of purchase, please

return it to your supplier in the first year with proof

of purchase and it will be replaced free of charge.

For years 2 and 3 or any difficulty in the first year

telephone the helpline on

***********.

For a product brochure please contact:

Timeguard Ltd. Victory Park, 400 Edgware Road,

London NW2 6ND Tel: 020-8452-1112

************************

A Group company

67-058-328

TRT037N

发布评论

评论列表 (0)

  1. 暂无评论