最新消息: USBMI致力于为网友们分享Windows、安卓、IOS等主流手机系统相关的资讯以及评测、同时提供相关教程、应用、软件下载等服务。

西门子低压电机启动器SIRIUS IEC启动器说明书

IT圈 admin 34浏览 0评论

2024年10月22日发(作者:城雅蕊)

5

POWER PRODUCT

Low Voltage Motor Starters

Contents

Selection 15-2

Full Voltage Non-Reversing

NEMA 4X Non-Metallic 15-4

Full Voltage Metallic 15-8

Non - Combination 15-9

Circuit Breaker Combination 15-10

Fusible Switch Combination and Non-Fusible Starter 15-11

Full Voltage Reversing

General 15-12

Non - Combination 15-13

Circuit Breaker Combination 15-14

Fusible Switch Combination and Non-Fusible Starter 15-15

Two Speed Starters

General 15-16

Two Windings, Constant or Variable Torque

Non - Combination 15-17

Circuit Breaker Combination 15-18

Fusible Switch Combination and Non-Fusible Starter 15-19

Single Winding, Constant or Variable Torque

Non - Combination 15-20

Circuit Breaker Combination 15-21

Fusible Switch Combination and Non-Fusible Starter 15-22

Overload Relay Chart 15-23

Factory Modifications

Selection 15-24

SIRIUS Pre - Assembled Starter Packages 15-29

Dimensions 15-32

Siemens SIRIUS IEC Starters

The SIRIUS IEC Starters line also offers more price

The SIRIUS IEC Starter is the new generation

flexibility in the very competitive starters market.

of IEC HP rated magnetic starters, designed to

meet and exceed today’s market requirements

SIRIUS Starters Features:

for HP rated starters.

b CSA approved

The new SIRIUS Starters take advantage of

b 100HP, 600V max

the reliability of the SIRIUS line of contactors

b Standard 2NO+2NC auxiliary contacts

and overload relays in addition to the new line

b Ambient 60°C on contactors

of SIGNUM 3SB3 22mm pilot devices as the

b Fast and simple 3-prong overload contactor

standard control device.

connection: no coil extension required

b Standard primary and secondary fusing on

As evident in the design and size, all efforts

control transformers

were put in place to offer a new line of starters

b Standard Metal 22mm SIGNUM Control Devices

that exceeds the performance of the previous

generation.

1NO auxiliary contact for starters up to 10HP at 600V.

MOTOR STARTERSLOW VOLTAGE

1

15

SIRIUS HP Rated Magnetic Starters

Catalogue Number Selection Guide

Starter SeriesDisconnect TypeStarter TypeEnclosure Type

Contactor

Ref. Number

Coil Voltage

Selection

Overload Relay

Setting Range

page 15-19

15

3RT1015

16

3RT1016

17

3RT1017

25

3RT1025

26

3RT1026

33

3RT1033

34

3RT1034

35

3RT1035

36

3RT1036

44

3RT1044

45

3RT1045

46

3RT1046

C

24V/60Hz

24V/50Hz

K

120V/60 Hz

110V/50Hz

M

208V/60Hz

P

240V/60Hz

220V/50Hz

V

460V/60Hz

380V/50Hz

T

600V/60Hz

Z

Others

Specify

OA to 4M

Standard

Class 10

bimetal

overload relay

RB

Optional

Class 20

electronic

overload relay

00

Provision for

field mounting

of overload relay

page 15-3-15-18

V

SIRIUS IEC

HP rated Starter

1

Non-combination

2

Circuit breaker

combination

3

Non-fusible

type

4

Fusible

combination

A

FVNR

B

FVR

N

2S1W

constant or variable

torque

R

2S1W

constant

horsepower

U

2S2W

constant

horsepower

W

2S2W

constant or variable

torque

B

CSA type 1

EEMAC type 1

general purpose

C

CSA type 5

EEMAC type 12

dust tight

industrial use

D

CSA type 4

EEMAC type 4

watertight

F

CSA type 4x

EEMAC type 4x

watertight

corrosion resistant

L

O

W

V

O

L

T

A

G

E

M

O

T

O

R

S

T

A

R

T

E

R

S

1

5

15-2

Siemens Canada Limited Power Product Catalogue

A.C. Magnetic Starters

Catalogue Number Selection Guide

Pilot Devices

Power Line

Voltage

Control Circuit

Additional

Auxiliary

Contacts

page 15-21

0

None

E

4 N.O.

F

1 N.O. + 1 N.C.

J

3 N.O. + 1 N.C.

K

2 N.C.

L

2 N.O.

M

2 N.O. + 2 N.C.

9

Other Specify

0

none

1 or 2

1 push button

extended

head red

3 or 4

1 twist lock

mushroom red

5 or 6

2 push buttons

1-red, 1-green

7 or 8

3 push buttons

1-red, 2-black

A or B

2 pos. selector switch

C or D

2 pos. selector switch

spring return

E or F

2 pos. selector switch

key operated

G or H

3 pos. selector switch

J or K

3 pos. selector switch

spring return

L or M

3 pos. selector switch

key operated

N or P

3 pos. selector switch

spring return key

operated

T or U

3 pos. selector switch

and 2 push buttons

START

STOP

for hand operation

9

Other Specify

Operators

Operators TypeLegend Plate(s)

Indicator

Type

page 15-22

0

none

A

EMERGENCY

STOP

B

STOP

C

START STOP

D

ON OFF

E to J

3 legend plates

for 3 push button

K to T

1 legend plate for

2 pos. selector

switch

1 to 8

1 legend plate for

3 pos. selector

switch

X

3 legend plates

for 3 pos. selector

switch and

START STOP

push button

9

Other Specify

0

none

1 or 2

Full Voltage

120V c/w

legend

plate(s)

3 or 4

Full Voltage

24V c/w

legend

plate(s)

5 or 6

Full Voltage

120V LED c/w

legend

plate(s)

7 or 8

Full Voltage

24V LED c/w

legend

plate(s)

A

Full Voltage

120V w/o

legend

plate(s)

B

Full Voltage

24V w/o

legend

plate(s)

C

Full Voltage

120V LED

w/o legend

plate(s)

D

Full Voltage

24V LED w/o

legend

plate(s)

9

Other

Specify

0

none

1 to 5

1 indicator

for

1 function

6 to 8

and

A to E

2 indicators

for

2 functions

F to R

3 indicators

for

3 functions

9

Other

Specify

each function

per colour

Indicators

Functions

Selection

Colour

Choice

page 15-20

6

600V Max.

Distributor Stock

1

120V/1Ph/60Hz

2

208V/3PH/60Hz

3

230V/3PH/60Hz

4

460V/3Ph/60Hz

5

575V/3Ph/60Hz

7

230V/1Ph/60Hz

8

208V/3Ph/60Hz

with

4 wires

(+Neutral)

9

Other

Specify

0

Separate control

circuit, unfused

N

Separate

control circuit,

fused

max 250V

P

One control fuse

for 120V 1 ph.

R

Standard control

transformer c/w

2 prim. & 1 sec.

120V fuse

U

Extra 50VA

capacity

Control

Transformer

W

Extra 100VA

capacity

Control

Transformer

9

Other

Specify

pages 15-21-15-22page 15-23

0

none

C to F

Colour

choice for

1 indicator

1 to 6

Colour

choice for

2 indicators

K to P

Colour

choice for

3 indicators

9

Other

Specify each

colour per

function

15

LOW VOLTAGE MOTOR STARTERS

Siemens Canada Limited Power Product Catalogue

15-3

Full Voltage Non-Reversing

NEMA 4X Non-Metallic

Non-Combination - Up to 10HP - 600V

Features

b High quality and reliability

b Up to 10HP at 600V rating

b 1 NO auxiliary contact

Selection

b Class 10 bimetal overload relays

including:

- Manual reset

- Phase Loss Protection

- Separate Trip or Alarm contact

b NEMA 4X polycarbonate enclosure

with conduit entry knockouts

b Offered in 120V AC separate control

b Wiring kit for single phase conversion

included

L

O

W

V

O

L

T

A

G

E

M

O

T

O

R

S

T

A

R

T

E

R

S

1

5

CSA Maximum HP Rating

Enclosed

Amps

11

11

11

1 phase

120V

0.5

0.5

0.5

240V

1.5

1.5

1.5

208V

3

3

3

3-phase

240V

3

3

3

480V

7.5

7.5

7.5

600V

10

10

10

Pilot

Devices

Mechanical

Start/Stop

Pushbutton

Coil

Voltage

24V

120V

240V

Aux. Contacts supplied as Enclosure Plastic

Contactor

standard per contactorCSA type 4X

Reference

NumberNONCOrder No.

3RE3110-00A17-1AB0

17103RE3110-00A17-1AK6

3RE3110-00A17-1AP6

2024年10月22日发(作者:城雅蕊)

5

POWER PRODUCT

Low Voltage Motor Starters

Contents

Selection 15-2

Full Voltage Non-Reversing

NEMA 4X Non-Metallic 15-4

Full Voltage Metallic 15-8

Non - Combination 15-9

Circuit Breaker Combination 15-10

Fusible Switch Combination and Non-Fusible Starter 15-11

Full Voltage Reversing

General 15-12

Non - Combination 15-13

Circuit Breaker Combination 15-14

Fusible Switch Combination and Non-Fusible Starter 15-15

Two Speed Starters

General 15-16

Two Windings, Constant or Variable Torque

Non - Combination 15-17

Circuit Breaker Combination 15-18

Fusible Switch Combination and Non-Fusible Starter 15-19

Single Winding, Constant or Variable Torque

Non - Combination 15-20

Circuit Breaker Combination 15-21

Fusible Switch Combination and Non-Fusible Starter 15-22

Overload Relay Chart 15-23

Factory Modifications

Selection 15-24

SIRIUS Pre - Assembled Starter Packages 15-29

Dimensions 15-32

Siemens SIRIUS IEC Starters

The SIRIUS IEC Starters line also offers more price

The SIRIUS IEC Starter is the new generation

flexibility in the very competitive starters market.

of IEC HP rated magnetic starters, designed to

meet and exceed today’s market requirements

SIRIUS Starters Features:

for HP rated starters.

b CSA approved

The new SIRIUS Starters take advantage of

b 100HP, 600V max

the reliability of the SIRIUS line of contactors

b Standard 2NO+2NC auxiliary contacts

and overload relays in addition to the new line

b Ambient 60°C on contactors

of SIGNUM 3SB3 22mm pilot devices as the

b Fast and simple 3-prong overload contactor

standard control device.

connection: no coil extension required

b Standard primary and secondary fusing on

As evident in the design and size, all efforts

control transformers

were put in place to offer a new line of starters

b Standard Metal 22mm SIGNUM Control Devices

that exceeds the performance of the previous

generation.

1NO auxiliary contact for starters up to 10HP at 600V.

MOTOR STARTERSLOW VOLTAGE

1

15

SIRIUS HP Rated Magnetic Starters

Catalogue Number Selection Guide

Starter SeriesDisconnect TypeStarter TypeEnclosure Type

Contactor

Ref. Number

Coil Voltage

Selection

Overload Relay

Setting Range

page 15-19

15

3RT1015

16

3RT1016

17

3RT1017

25

3RT1025

26

3RT1026

33

3RT1033

34

3RT1034

35

3RT1035

36

3RT1036

44

3RT1044

45

3RT1045

46

3RT1046

C

24V/60Hz

24V/50Hz

K

120V/60 Hz

110V/50Hz

M

208V/60Hz

P

240V/60Hz

220V/50Hz

V

460V/60Hz

380V/50Hz

T

600V/60Hz

Z

Others

Specify

OA to 4M

Standard

Class 10

bimetal

overload relay

RB

Optional

Class 20

electronic

overload relay

00

Provision for

field mounting

of overload relay

page 15-3-15-18

V

SIRIUS IEC

HP rated Starter

1

Non-combination

2

Circuit breaker

combination

3

Non-fusible

type

4

Fusible

combination

A

FVNR

B

FVR

N

2S1W

constant or variable

torque

R

2S1W

constant

horsepower

U

2S2W

constant

horsepower

W

2S2W

constant or variable

torque

B

CSA type 1

EEMAC type 1

general purpose

C

CSA type 5

EEMAC type 12

dust tight

industrial use

D

CSA type 4

EEMAC type 4

watertight

F

CSA type 4x

EEMAC type 4x

watertight

corrosion resistant

L

O

W

V

O

L

T

A

G

E

M

O

T

O

R

S

T

A

R

T

E

R

S

1

5

15-2

Siemens Canada Limited Power Product Catalogue

A.C. Magnetic Starters

Catalogue Number Selection Guide

Pilot Devices

Power Line

Voltage

Control Circuit

Additional

Auxiliary

Contacts

page 15-21

0

None

E

4 N.O.

F

1 N.O. + 1 N.C.

J

3 N.O. + 1 N.C.

K

2 N.C.

L

2 N.O.

M

2 N.O. + 2 N.C.

9

Other Specify

0

none

1 or 2

1 push button

extended

head red

3 or 4

1 twist lock

mushroom red

5 or 6

2 push buttons

1-red, 1-green

7 or 8

3 push buttons

1-red, 2-black

A or B

2 pos. selector switch

C or D

2 pos. selector switch

spring return

E or F

2 pos. selector switch

key operated

G or H

3 pos. selector switch

J or K

3 pos. selector switch

spring return

L or M

3 pos. selector switch

key operated

N or P

3 pos. selector switch

spring return key

operated

T or U

3 pos. selector switch

and 2 push buttons

START

STOP

for hand operation

9

Other Specify

Operators

Operators TypeLegend Plate(s)

Indicator

Type

page 15-22

0

none

A

EMERGENCY

STOP

B

STOP

C

START STOP

D

ON OFF

E to J

3 legend plates

for 3 push button

K to T

1 legend plate for

2 pos. selector

switch

1 to 8

1 legend plate for

3 pos. selector

switch

X

3 legend plates

for 3 pos. selector

switch and

START STOP

push button

9

Other Specify

0

none

1 or 2

Full Voltage

120V c/w

legend

plate(s)

3 or 4

Full Voltage

24V c/w

legend

plate(s)

5 or 6

Full Voltage

120V LED c/w

legend

plate(s)

7 or 8

Full Voltage

24V LED c/w

legend

plate(s)

A

Full Voltage

120V w/o

legend

plate(s)

B

Full Voltage

24V w/o

legend

plate(s)

C

Full Voltage

120V LED

w/o legend

plate(s)

D

Full Voltage

24V LED w/o

legend

plate(s)

9

Other

Specify

0

none

1 to 5

1 indicator

for

1 function

6 to 8

and

A to E

2 indicators

for

2 functions

F to R

3 indicators

for

3 functions

9

Other

Specify

each function

per colour

Indicators

Functions

Selection

Colour

Choice

page 15-20

6

600V Max.

Distributor Stock

1

120V/1Ph/60Hz

2

208V/3PH/60Hz

3

230V/3PH/60Hz

4

460V/3Ph/60Hz

5

575V/3Ph/60Hz

7

230V/1Ph/60Hz

8

208V/3Ph/60Hz

with

4 wires

(+Neutral)

9

Other

Specify

0

Separate control

circuit, unfused

N

Separate

control circuit,

fused

max 250V

P

One control fuse

for 120V 1 ph.

R

Standard control

transformer c/w

2 prim. & 1 sec.

120V fuse

U

Extra 50VA

capacity

Control

Transformer

W

Extra 100VA

capacity

Control

Transformer

9

Other

Specify

pages 15-21-15-22page 15-23

0

none

C to F

Colour

choice for

1 indicator

1 to 6

Colour

choice for

2 indicators

K to P

Colour

choice for

3 indicators

9

Other

Specify each

colour per

function

15

LOW VOLTAGE MOTOR STARTERS

Siemens Canada Limited Power Product Catalogue

15-3

Full Voltage Non-Reversing

NEMA 4X Non-Metallic

Non-Combination - Up to 10HP - 600V

Features

b High quality and reliability

b Up to 10HP at 600V rating

b 1 NO auxiliary contact

Selection

b Class 10 bimetal overload relays

including:

- Manual reset

- Phase Loss Protection

- Separate Trip or Alarm contact

b NEMA 4X polycarbonate enclosure

with conduit entry knockouts

b Offered in 120V AC separate control

b Wiring kit for single phase conversion

included

L

O

W

V

O

L

T

A

G

E

M

O

T

O

R

S

T

A

R

T

E

R

S

1

5

CSA Maximum HP Rating

Enclosed

Amps

11

11

11

1 phase

120V

0.5

0.5

0.5

240V

1.5

1.5

1.5

208V

3

3

3

3-phase

240V

3

3

3

480V

7.5

7.5

7.5

600V

10

10

10

Pilot

Devices

Mechanical

Start/Stop

Pushbutton

Coil

Voltage

24V

120V

240V

Aux. Contacts supplied as Enclosure Plastic

Contactor

standard per contactorCSA type 4X

Reference

NumberNONCOrder No.

3RE3110-00A17-1AB0

17103RE3110-00A17-1AK6

3RE3110-00A17-1AP6

发布评论

评论列表 (0)

  1. 暂无评论