Argantix XDS Series
Overview
• Compact Modular DC Power
5, 10 and 15 KW versions in 3U, 19” rack.
• Wide Range of Applications
Telecommunications, automotive, industrial and
commercial applications.
• Built-in Measurements
Voltage, current and power readback
capability standard.
• Fast Transient Response
Capable of driving demanding loads.
• Parallel / Current Share Capability
Paralleled chassis can deliver up to 75 KW.
• Standard RS232C Interface and Optional GPIB.
Instrument drivers and software support for easy
system integration.
functions and measurements and allows for easy
integration into ATE systems. Use of standard
SCPI command language syntax and instrument
drivers for popular programming environments
further ease system integration. An optional GPIB
interface is available as well.
XDS Series - GUI Software
All XDS Series Power Supplies come with
Windows GUI software. This GUI program
offers additional functionality. This includes the
following capabilities:
Output Sequencing: Time driven output
changes can be programmed, stored and
executed under program control. Events include
steps, sweeps, drops and surges of voltage and/or
current. This allows a variety of power conditions
and DC tests to be set up without having to
develop application specific code. Multiple setups
can be stored on disk.
Data Logging: All measurements taken from the
DC supply can be recorded to disk in a format
that is easily exported to other programs such as
MS Excel for analysis and display.
Pass/Fail Testing: Automatic output sequencing
and data read back with user defined pass/fail
criteria. This mode may be used for burn-in or
product evaluation applications. A simple to use
spreadsheet-like user interface allows entry of
time delays, settings, readings and pass/fail limits.
Any number of setups can be saved to disk for
future use.
The GUI program operates over the standard
RS232C interface or the optional IEEE-488/GPIB
interface and provides comprehensive on-line
help.
5–15 kW
30–600 V
8–500 A
208400480
Compact Power
The XDS Series packs up to 15 KW of DC power
into a 5.25” rack mount chassis. Despite the
high power density of this design, the XDS Series
provides a low noise, stable output.
A full set of measurements is built-in to provide
instant feedback on EUT load characteristics.
The XDS Series offers all the basic DC power
supply capabilities needed for a wide range of
applications and provides cost effective alternative
to larger and more expensive products typically
used for these applications.
Easy To Use Controls
Simple menu driven operation and familiar rotary
controls for setting voltage and current ensures
that the XDS Series Power Supplies are easy
to operate. All front panel controls including
the rotary knobs are digitally encoded for long
lasting, trouble free operation. The voltage and
current control knobs can be used to quickly slew
output parameters.
The intuitive front panel controls allow for easy
operation of the supply by both novice and
experienced users alike.
Applications
With excellent output regulation and accuracy,
the XDS Series DC Power Supplies support a
wide variety of DC power applications. Examples
include communications, semiconductors,
automotive, information technology and
industrial. The standard RS232C serial interface
supports remote control of all power supply
AMETEK
Programmable Power
9250 Brown Deer Road
San Diego, CA 92121-2267
USA
858.458.0223
***************************67
XDS Series
XDS Series - Models¹ : Output
Model
XDS 30-167
XDS 30-333
XDS 30-500
XDS 40-125
XDS 40-250
XDS 40-375
XDS 50-100
XDS 50-200
XDS 50-300
XDS 80-62
XDS 80-125
XDS 80-187
XDS 100-50
XDS 100-100
DS 100-150
Voltage
0-30
0-30
0-30
0-40
0-40
0-40
0-50
0-50
0-50
0-80
0-80
0-80
0-100
0-100
0-100
Current
0-167
0-333
0-500
0-125
0-250
0-375
0-100
0-200
0-300
0-62
0-125
0-187
0-50
0-100
0-150
RMS Noise
15mv
15mv
15mv
15mv
15mv
15mv
15mv
15mv
15mv
25mv
25mv
25mv
25mv
25mv
25mv
Model
XDS 150-33
XDS 150-66
XDS 150-100
XDS 300-17
XDS 300-33
XDS 300-50
XDS 400-12
XDS 400-25
XDS 400-37
XDS 600-8
XDS 600-17
XDS 600-25
Vpltage
0-150
0-150
0-150
0-300
0-300
0-300
0-400
0-400
0-400
0-600
0-600
0-600
Current
0-33
0-66
0-100
0-17
0-33
0-50
0-12.5
0-25
0-37
0-8
0-17
0-25
RMS Noise
25mv
25mv
25mv
100mv
100mv
100mv
100mv
100mv
100mv
250mv
250mv
250mv
Electrical
Output
Power Maximum 5, 10 or 15 KW
Voltage Accuracy: 0.3 % FS
Resolution: 0.033 % FS
Line Regulation: < 0.1% of V range
Load Regulation: < 0.1% of V range
Transient Response: Voltage will recover
to within 2% of V range within 2 msec
for 30 % load step.
Stability: ± 0.05% of max. rating per 8
hours after 30 mins. warmup period.
Current Accuracy: 0.5% FS at 0-100% of range
Resolution: 0.1%-0.033 %
(model specific)
Line Regulation: < 0.1% of I range
Load Regulation: < 0.1% of I range
Stability: ± 0.05% of max. rating per 8
hours after 30 mins. warmup period
Input
Voltage: 208 - 10 % to 230 +
10% VAC
400 ± 10 % VAC (option -400)
480 ± 10 % VAC (option -480)
All inputs are L-L, 3 phase, 3-
wire plus safety ground.
Current RMS: Typical RMS current per
phase at low line input voltage.
Power Factor: > 0.65
Efficiency: > 85 % at full load.
Power Level
Vlow
187 V
360 V
432 V
5 kW
27 A
15 A
12A
10 kW
54 A
30 A
24 A
15 kW
81 A
45 A
36 A
Measurements
Voltage
Model
XDS 30-XXX
XDS 40-XXX
XDS 50-XXX
XDS 80-XXX
XDS 100-XXX
XDS 150-XXX
XDS 300-XXX
XDS 400-XXX
XDS 600-XXX
Current
Current Range
0 - 8.3 A
0 - 16 A
0 - 33 A
0 - 66 A
0 - 187 A
0 - 400 A
0 - 500 A
Power
Range
0 - 5 KW
0 - 10 KW
0 - 15 KW
Resolution
0.01 V
0.01 V
0.02 V
0.02 V
0.1 V
0.1 V
0.1 V
0.1 V
0.2 V
Resolution
0.003 A
0.005 A
0.01 A
0.02 A
0.1 A
0.1 A
0.2 A
Resolution
1 W
2 W
5 W
Accuracy
0.05 V
0.05 V
0.1 V
0.1 V
0.2 V
0.3 V
0.5 V
0.5 V
1.0 V
Accuracy
0.013 A
0.025 A
0.05 A
0.1 A
0.3 A
0.5 A
1 A
Accuracy
0.3 % FS
0.3 % FS
0.3 % FS
Peak Current
Resolution: See current table Accuracy: Same as
current + 3 x resolution.
Protection
Over temperature, short circuit, over
current protection
XDS Series
Controls and Indicator
Controls
Voltage setting: Digitally encoded rotary knob
Current setting: Digitally encoded rotary knob
Measurement select: Push button
Output on/off: Push button
Power on/off: Toggle switch
Indicators
Display: Dual 7 segment large LED
LED’s for: Output on/off, cc mode, cv mode,
remote, measurements.
Remote Control
A standard RS232C and analog RPV (0-10 VDC)
are included with all XDS Series DC Power
Supplies. An optional GPIB/IEEE-488 input is
available as well.
RS232C - Standard
9 pin D-shell connector, 19200 baud, SCPI syntax
RPV Input - Standard
Input: 0-10 VDC for 0-100% range
Connector: 15 pin D-sub.
Remote Inhibit - Standard
Programmable for default high or low
Weight 15 KW 10 KW 5KW
Net: 90 lbs. 70 lbs. 50 lbs.
41 Kg 32 Kg 23 Kg
Shipping (approx.):
125 lbs. 105 lbs. 85 lbs.
57 Kg 48 Kg 39 Kg
Rack Mounting: Unit must be supported by shelf
or brackets when mounted in 19” cabinet. No
provisions for rack slides are made on instrument.
5–15 kW
Ordering Information
Model
All XDS Series model numbers specify voltage and
current range.
XDS VVV-CCC-LLL-XX-XXXXX
VVV = Voltage
CCC = Current
LLL = Input Line Voltage
XX = Options
XXXXX = Configuration
Refer to table shown for model numbers and
configurations.
Includes
•
User manual and programming manual
on CD ROM.
•
Windows GUI software on CD ROM.
•
RS-232C serial cable
Options
-IF GPIB / IEEE-488 interface
programming option.
-400 400 ±10% volt line to line AC input
-480 480 ±10% volt line to line AC input
Optional Configurations
-AUX Auxilliary control.
-RPV5 Remote voltage programming, 0-5V
-RPV10 Remote voltage programming, 0-10V
-RPC5 Remote current programming, 0-5V
-RPC10 Remote current programming, 0-10V
-IF Option
IEEE-488 Interface
IEEE-488 (GPIB) talker listener.
Subset: AH1, L3, RL2, SH1, T8
IEEE-488.2 SCPI syntax
Environmental
Temperature Coefficient
Voltage set point: 0.02%/°C of V Range
Current set point: 0.03%/°C of I Range
Ambient Temperature
Operating: 0° to 40° C / 32° to 104° F
Storage: -40° to 75° C / -40° to 167° F
Humidity
Operating: 0 to 80% RH, non condensing
Cooling
Forced air, side and top intake, rear exhaust
Ordering Examples:
Model Description
XDS 50-100-208 Output voltage range is 50 Vdc,
maximum current is 100 Adc, line input is 208
V line to line, three phase. Includes standard
RS232C and analog interfaces.
XDS 80-187-400-IF Output voltage range is 80
Vdc, maximum current is 187 Adc, line input is
400 V line to line, three phase. Includes optional
IEEE/RS232 and analog interfaces.
Mechanical
Dimensions
Height: 5.25” / 133.35 mm
Width: 19” / 482.6 mm
Depth: 22.19” / 563.3 mm excl. bus
bars and cover
24.74” / 628.4 mm incl. bus
bars and cover
© 2009 AMETEK Programmable Power All rights reserved. AMETEK Programmable Power is the trademark of AMETEK Inc., registered in the U.S. and other countries.
Elgar, Sorensen, California Instruments, and Power Ten are trademarks of AMETEK Inc., registered in the U.S.
858.458.0223
sales@69
Notes
2024年10月27日发(作者:闻嘉佑)
®
Advanced Test Equipment Rentals
800-404-ATEC (2832)
E
s
t
a
b
l
i
s
h
e
d
1
9
8
1
Argantix XDS Series
Overview
• Compact Modular DC Power
5, 10 and 15 KW versions in 3U, 19” rack.
• Wide Range of Applications
Telecommunications, automotive, industrial and
commercial applications.
• Built-in Measurements
Voltage, current and power readback
capability standard.
• Fast Transient Response
Capable of driving demanding loads.
• Parallel / Current Share Capability
Paralleled chassis can deliver up to 75 KW.
• Standard RS232C Interface and Optional GPIB.
Instrument drivers and software support for easy
system integration.
functions and measurements and allows for easy
integration into ATE systems. Use of standard
SCPI command language syntax and instrument
drivers for popular programming environments
further ease system integration. An optional GPIB
interface is available as well.
XDS Series - GUI Software
All XDS Series Power Supplies come with
Windows GUI software. This GUI program
offers additional functionality. This includes the
following capabilities:
Output Sequencing: Time driven output
changes can be programmed, stored and
executed under program control. Events include
steps, sweeps, drops and surges of voltage and/or
current. This allows a variety of power conditions
and DC tests to be set up without having to
develop application specific code. Multiple setups
can be stored on disk.
Data Logging: All measurements taken from the
DC supply can be recorded to disk in a format
that is easily exported to other programs such as
MS Excel for analysis and display.
Pass/Fail Testing: Automatic output sequencing
and data read back with user defined pass/fail
criteria. This mode may be used for burn-in or
product evaluation applications. A simple to use
spreadsheet-like user interface allows entry of
time delays, settings, readings and pass/fail limits.
Any number of setups can be saved to disk for
future use.
The GUI program operates over the standard
RS232C interface or the optional IEEE-488/GPIB
interface and provides comprehensive on-line
help.
5–15 kW
30–600 V
8–500 A
208400480
Compact Power
The XDS Series packs up to 15 KW of DC power
into a 5.25” rack mount chassis. Despite the
high power density of this design, the XDS Series
provides a low noise, stable output.
A full set of measurements is built-in to provide
instant feedback on EUT load characteristics.
The XDS Series offers all the basic DC power
supply capabilities needed for a wide range of
applications and provides cost effective alternative
to larger and more expensive products typically
used for these applications.
Easy To Use Controls
Simple menu driven operation and familiar rotary
controls for setting voltage and current ensures
that the XDS Series Power Supplies are easy
to operate. All front panel controls including
the rotary knobs are digitally encoded for long
lasting, trouble free operation. The voltage and
current control knobs can be used to quickly slew
output parameters.
The intuitive front panel controls allow for easy
operation of the supply by both novice and
experienced users alike.
Applications
With excellent output regulation and accuracy,
the XDS Series DC Power Supplies support a
wide variety of DC power applications. Examples
include communications, semiconductors,
automotive, information technology and
industrial. The standard RS232C serial interface
supports remote control of all power supply
AMETEK
Programmable Power
9250 Brown Deer Road
San Diego, CA 92121-2267
USA
858.458.0223
***************************67
XDS Series
XDS Series - Models¹ : Output
Model
XDS 30-167
XDS 30-333
XDS 30-500
XDS 40-125
XDS 40-250
XDS 40-375
XDS 50-100
XDS 50-200
XDS 50-300
XDS 80-62
XDS 80-125
XDS 80-187
XDS 100-50
XDS 100-100
DS 100-150
Voltage
0-30
0-30
0-30
0-40
0-40
0-40
0-50
0-50
0-50
0-80
0-80
0-80
0-100
0-100
0-100
Current
0-167
0-333
0-500
0-125
0-250
0-375
0-100
0-200
0-300
0-62
0-125
0-187
0-50
0-100
0-150
RMS Noise
15mv
15mv
15mv
15mv
15mv
15mv
15mv
15mv
15mv
25mv
25mv
25mv
25mv
25mv
25mv
Model
XDS 150-33
XDS 150-66
XDS 150-100
XDS 300-17
XDS 300-33
XDS 300-50
XDS 400-12
XDS 400-25
XDS 400-37
XDS 600-8
XDS 600-17
XDS 600-25
Vpltage
0-150
0-150
0-150
0-300
0-300
0-300
0-400
0-400
0-400
0-600
0-600
0-600
Current
0-33
0-66
0-100
0-17
0-33
0-50
0-12.5
0-25
0-37
0-8
0-17
0-25
RMS Noise
25mv
25mv
25mv
100mv
100mv
100mv
100mv
100mv
100mv
250mv
250mv
250mv
Electrical
Output
Power Maximum 5, 10 or 15 KW
Voltage Accuracy: 0.3 % FS
Resolution: 0.033 % FS
Line Regulation: < 0.1% of V range
Load Regulation: < 0.1% of V range
Transient Response: Voltage will recover
to within 2% of V range within 2 msec
for 30 % load step.
Stability: ± 0.05% of max. rating per 8
hours after 30 mins. warmup period.
Current Accuracy: 0.5% FS at 0-100% of range
Resolution: 0.1%-0.033 %
(model specific)
Line Regulation: < 0.1% of I range
Load Regulation: < 0.1% of I range
Stability: ± 0.05% of max. rating per 8
hours after 30 mins. warmup period
Input
Voltage: 208 - 10 % to 230 +
10% VAC
400 ± 10 % VAC (option -400)
480 ± 10 % VAC (option -480)
All inputs are L-L, 3 phase, 3-
wire plus safety ground.
Current RMS: Typical RMS current per
phase at low line input voltage.
Power Factor: > 0.65
Efficiency: > 85 % at full load.
Power Level
Vlow
187 V
360 V
432 V
5 kW
27 A
15 A
12A
10 kW
54 A
30 A
24 A
15 kW
81 A
45 A
36 A
Measurements
Voltage
Model
XDS 30-XXX
XDS 40-XXX
XDS 50-XXX
XDS 80-XXX
XDS 100-XXX
XDS 150-XXX
XDS 300-XXX
XDS 400-XXX
XDS 600-XXX
Current
Current Range
0 - 8.3 A
0 - 16 A
0 - 33 A
0 - 66 A
0 - 187 A
0 - 400 A
0 - 500 A
Power
Range
0 - 5 KW
0 - 10 KW
0 - 15 KW
Resolution
0.01 V
0.01 V
0.02 V
0.02 V
0.1 V
0.1 V
0.1 V
0.1 V
0.2 V
Resolution
0.003 A
0.005 A
0.01 A
0.02 A
0.1 A
0.1 A
0.2 A
Resolution
1 W
2 W
5 W
Accuracy
0.05 V
0.05 V
0.1 V
0.1 V
0.2 V
0.3 V
0.5 V
0.5 V
1.0 V
Accuracy
0.013 A
0.025 A
0.05 A
0.1 A
0.3 A
0.5 A
1 A
Accuracy
0.3 % FS
0.3 % FS
0.3 % FS
Peak Current
Resolution: See current table Accuracy: Same as
current + 3 x resolution.
Protection
Over temperature, short circuit, over
current protection
XDS Series
Controls and Indicator
Controls
Voltage setting: Digitally encoded rotary knob
Current setting: Digitally encoded rotary knob
Measurement select: Push button
Output on/off: Push button
Power on/off: Toggle switch
Indicators
Display: Dual 7 segment large LED
LED’s for: Output on/off, cc mode, cv mode,
remote, measurements.
Remote Control
A standard RS232C and analog RPV (0-10 VDC)
are included with all XDS Series DC Power
Supplies. An optional GPIB/IEEE-488 input is
available as well.
RS232C - Standard
9 pin D-shell connector, 19200 baud, SCPI syntax
RPV Input - Standard
Input: 0-10 VDC for 0-100% range
Connector: 15 pin D-sub.
Remote Inhibit - Standard
Programmable for default high or low
Weight 15 KW 10 KW 5KW
Net: 90 lbs. 70 lbs. 50 lbs.
41 Kg 32 Kg 23 Kg
Shipping (approx.):
125 lbs. 105 lbs. 85 lbs.
57 Kg 48 Kg 39 Kg
Rack Mounting: Unit must be supported by shelf
or brackets when mounted in 19” cabinet. No
provisions for rack slides are made on instrument.
5–15 kW
Ordering Information
Model
All XDS Series model numbers specify voltage and
current range.
XDS VVV-CCC-LLL-XX-XXXXX
VVV = Voltage
CCC = Current
LLL = Input Line Voltage
XX = Options
XXXXX = Configuration
Refer to table shown for model numbers and
configurations.
Includes
•
User manual and programming manual
on CD ROM.
•
Windows GUI software on CD ROM.
•
RS-232C serial cable
Options
-IF GPIB / IEEE-488 interface
programming option.
-400 400 ±10% volt line to line AC input
-480 480 ±10% volt line to line AC input
Optional Configurations
-AUX Auxilliary control.
-RPV5 Remote voltage programming, 0-5V
-RPV10 Remote voltage programming, 0-10V
-RPC5 Remote current programming, 0-5V
-RPC10 Remote current programming, 0-10V
-IF Option
IEEE-488 Interface
IEEE-488 (GPIB) talker listener.
Subset: AH1, L3, RL2, SH1, T8
IEEE-488.2 SCPI syntax
Environmental
Temperature Coefficient
Voltage set point: 0.02%/°C of V Range
Current set point: 0.03%/°C of I Range
Ambient Temperature
Operating: 0° to 40° C / 32° to 104° F
Storage: -40° to 75° C / -40° to 167° F
Humidity
Operating: 0 to 80% RH, non condensing
Cooling
Forced air, side and top intake, rear exhaust
Ordering Examples:
Model Description
XDS 50-100-208 Output voltage range is 50 Vdc,
maximum current is 100 Adc, line input is 208
V line to line, three phase. Includes standard
RS232C and analog interfaces.
XDS 80-187-400-IF Output voltage range is 80
Vdc, maximum current is 187 Adc, line input is
400 V line to line, three phase. Includes optional
IEEE/RS232 and analog interfaces.
Mechanical
Dimensions
Height: 5.25” / 133.35 mm
Width: 19” / 482.6 mm
Depth: 22.19” / 563.3 mm excl. bus
bars and cover
24.74” / 628.4 mm incl. bus
bars and cover
© 2009 AMETEK Programmable Power All rights reserved. AMETEK Programmable Power is the trademark of AMETEK Inc., registered in the U.S. and other countries.
Elgar, Sorensen, California Instruments, and Power Ten are trademarks of AMETEK Inc., registered in the U.S.
858.458.0223
sales@69
Notes