Eaton PXM8051A1BB

Power Xpert Meter 8000, Premium PQ with transient capture, 8

GB, Standard 100-240 Vac or 110-250 Vdc power supply,

Communications expansion card with 10/100 Base-T, 100F, RS-

485, RS-232 ports

Product NameCatalog Number

Eaton Power Xpert meter 8000PXM8051A1BB

UPCProduct Length/Depth

7866854249659.56 in

Product HeightProduct Width

8.32 in6.72 in

Product WeightWarranty

7.1 lb1 year

CompliancesCertifications

CE Marked UL Listed file 61010-1

CFR 47 FCC Part 15EN 61010-1

EN 60687

IEC 60687

IEC 61326

ANSI/IEEE Std C12.20

Waveform capture sampling rate

4096 Oversampling/cycle

Special features

Includes Com. Exp., I/O Cards

%Thd - current and voltage

To 127th

Logging

Event Log

Data Logging

LED alarm indicator

Min/Max Log

Audible Alarm

Email on alarm

Time / date stamp

Modification 1

Standard communications module with RS-485

Power quality analysis

SEMI F47

View Harmonic Spectrum At Device

PQ Index Graph -Premium

Number Of 9'S Availability

Crest Factor

ITIC Performance Curve

Flicker

K-Factor

Modification 2

Communications expansion card with 10/100 Base-T, 100F, RS-

485, RS-232 ports

Memory

8 GB

Communications

1 x Local Ethernet Port for configuration

Modbus TCP

Network Time Protocol (NTP)

Modbus RTU (RS-485) :2nd

BACnet/IP

File Transfer Protocol (FTP) built-in

10/100 RJ-45 Ethernet Port

Simple Network Management Protocol (SNMP)

1xRS-485

Brochures

Eaton's enclosed meter family

Power Xpert Meters 4000/6000/8000

Power Xpert Meter 4000/6000/8000 power quality and energy meter

Power Xpert Meter 4000/6000/8000 meter advanced 12-inch touch

screen display

Enterprise Data Center Solutions

Case studies

Eaton's Power Xpert: the heart of Ave Maria University's cost-saving power

monitoring system

Catalogs

Metering devices

Eaton's Volume 3—Power Distribution and Control Assemblies

Installation instructions

Back to back meter to display projection mount adapter kit assembly

instructions for PXM 6 display (PX-PMBD)

Power Xpert Meter 4000/6000/8000 User Manual Addendum for DNP

3.0

Manuals and user guides

First generation PXM 4/6/8K meter 6 color touchscreen display quick

start guide

Power Xpert Meter 4000/6000/8000 quick start guide

First generation PXM 4/6/8K meter user and installation manual with Java

UI

First generation PXM 4/6/8K meter advanced display quick start guide

with Java

First generation PXM 4/6/8K meter quick start guide with Java UI

BACnet object list for Power Xpert Meter 4000/6000/8000

PXM 4/6/8K DNP3 Ethernet communcations user manual

Modbus register map for Power Xpert meter 4000/6000/8000

First generation PXM 4/6/8K meter quick start guide

Power Xpert Meter 4000/6000/8000 user and installation manual

Power Xpert meter mobile quick start guide

First generation PXM 4/6/8K meter DNP3 Ethernet communications user

manual

Multimedia

Power Systems Experience Center Tour – Metering Focus

Email (SMTP)

Fiber-optic Ethernet Port

Internet/HTTP Server built-in

Instrumentation

Demand Metering

Current & Voltage - % Phase Unbalance - EVENT SETTING

ONLY

Current Demand

Watts

Watt Demand

Vah

Apparent Power Factor

Displacement Power Factor

Varh

Time Of Use Energy

4 Quadrant Energy

Wh --Positive & Negative

Per Phase Power Factor

Current & Voltage - 3 Phase Average

Va demand

Frequency

Current & Voltage - Per Phase

Voltage Neutral-Ground

View current & voltage phasors on display

Va

Current & Voltage - 3 Phase Min, Max

Wh --Net

Vars

Ground Current

Neutral Current

Type

Premium PQ with transient capture

Waveform analysis

Voltage Disturbance Wave Capture Trigger

Waveform recording duration - 60 cycles

Comtrade - Standard IEEE File Format

Waveform Captured On Threshold / Input

Captured Waveforms Displayed on Meter/GUI

Excess Dv/Dt Or Interruption Capture Trigger

Impulse transient capture

6MHZ

Individual harmonics magnitude

To 85th

Current sensor input

5A

Upgrading your Power Xpert Meter to HTML5, PXM 4/6/8K Series

Edition

The New Power Xpert Meter Web Interface, Step 3: Navigating the New

UI

The New Power Xpert Meter Web Interface, Step 1: Getting Started with

the New UI

The New Power Xpert Meter Web Interface, Step 4: Accessing the Meter

with a Tablet

The New Power Xpert Meter Web Interface, Step 2: Navigating the New

UI

Power Xpert Meters

Specifications and datasheets

Eaton Power Xpert Meter 4000/6000/8000 power quality and energy

meters

White papers

Next generation power quality meters white paper

I/O capability

Synchronize Demand Window Pulse Input

Load Shedding

Prog. Pulse Output --Wh, Varh, Vah

Programmable Relay Outputs -5

Programmable Discrete Inputs - 8

KYZ output

Voltage Disturbance Trip

ANSI % revenue accuracy

C12.20 (0.2)

Modification 3

I/O option card (8 digital inputs, 2 solid state outputs, 3 relay

outputs)

Power supply voltage

100-240 V, 110-250 Vdc

Eaton Corporation plc

Eaton House

30 Pembroke Road

Dublin 4, Ireland

Eaton is a registered trademark.

All other trademarks are

© 2023 Eaton. All Rights property of their respective

Reserved. owners.

/socialmedia

2024年10月27日发(作者:续丽君)

Eaton PXM8051A1BB

Power Xpert Meter 8000, Premium PQ with transient capture, 8

GB, Standard 100-240 Vac or 110-250 Vdc power supply,

Communications expansion card with 10/100 Base-T, 100F, RS-

485, RS-232 ports

Product NameCatalog Number

Eaton Power Xpert meter 8000PXM8051A1BB

UPCProduct Length/Depth

7866854249659.56 in

Product HeightProduct Width

8.32 in6.72 in

Product WeightWarranty

7.1 lb1 year

CompliancesCertifications

CE Marked UL Listed file 61010-1

CFR 47 FCC Part 15EN 61010-1

EN 60687

IEC 60687

IEC 61326

ANSI/IEEE Std C12.20

Waveform capture sampling rate

4096 Oversampling/cycle

Special features

Includes Com. Exp., I/O Cards

%Thd - current and voltage

To 127th

Logging

Event Log

Data Logging

LED alarm indicator

Min/Max Log

Audible Alarm

Email on alarm

Time / date stamp

Modification 1

Standard communications module with RS-485

Power quality analysis

SEMI F47

View Harmonic Spectrum At Device

PQ Index Graph -Premium

Number Of 9'S Availability

Crest Factor

ITIC Performance Curve

Flicker

K-Factor

Modification 2

Communications expansion card with 10/100 Base-T, 100F, RS-

485, RS-232 ports

Memory

8 GB

Communications

1 x Local Ethernet Port for configuration

Modbus TCP

Network Time Protocol (NTP)

Modbus RTU (RS-485) :2nd

BACnet/IP

File Transfer Protocol (FTP) built-in

10/100 RJ-45 Ethernet Port

Simple Network Management Protocol (SNMP)

1xRS-485

Brochures

Eaton's enclosed meter family

Power Xpert Meters 4000/6000/8000

Power Xpert Meter 4000/6000/8000 power quality and energy meter

Power Xpert Meter 4000/6000/8000 meter advanced 12-inch touch

screen display

Enterprise Data Center Solutions

Case studies

Eaton's Power Xpert: the heart of Ave Maria University's cost-saving power

monitoring system

Catalogs

Metering devices

Eaton's Volume 3—Power Distribution and Control Assemblies

Installation instructions

Back to back meter to display projection mount adapter kit assembly

instructions for PXM 6 display (PX-PMBD)

Power Xpert Meter 4000/6000/8000 User Manual Addendum for DNP

3.0

Manuals and user guides

First generation PXM 4/6/8K meter 6 color touchscreen display quick

start guide

Power Xpert Meter 4000/6000/8000 quick start guide

First generation PXM 4/6/8K meter user and installation manual with Java

UI

First generation PXM 4/6/8K meter advanced display quick start guide

with Java

First generation PXM 4/6/8K meter quick start guide with Java UI

BACnet object list for Power Xpert Meter 4000/6000/8000

PXM 4/6/8K DNP3 Ethernet communcations user manual

Modbus register map for Power Xpert meter 4000/6000/8000

First generation PXM 4/6/8K meter quick start guide

Power Xpert Meter 4000/6000/8000 user and installation manual

Power Xpert meter mobile quick start guide

First generation PXM 4/6/8K meter DNP3 Ethernet communications user

manual

Multimedia

Power Systems Experience Center Tour – Metering Focus

Email (SMTP)

Fiber-optic Ethernet Port

Internet/HTTP Server built-in

Instrumentation

Demand Metering

Current & Voltage - % Phase Unbalance - EVENT SETTING

ONLY

Current Demand

Watts

Watt Demand

Vah

Apparent Power Factor

Displacement Power Factor

Varh

Time Of Use Energy

4 Quadrant Energy

Wh --Positive & Negative

Per Phase Power Factor

Current & Voltage - 3 Phase Average

Va demand

Frequency

Current & Voltage - Per Phase

Voltage Neutral-Ground

View current & voltage phasors on display

Va

Current & Voltage - 3 Phase Min, Max

Wh --Net

Vars

Ground Current

Neutral Current

Type

Premium PQ with transient capture

Waveform analysis

Voltage Disturbance Wave Capture Trigger

Waveform recording duration - 60 cycles

Comtrade - Standard IEEE File Format

Waveform Captured On Threshold / Input

Captured Waveforms Displayed on Meter/GUI

Excess Dv/Dt Or Interruption Capture Trigger

Impulse transient capture

6MHZ

Individual harmonics magnitude

To 85th

Current sensor input

5A

Upgrading your Power Xpert Meter to HTML5, PXM 4/6/8K Series

Edition

The New Power Xpert Meter Web Interface, Step 3: Navigating the New

UI

The New Power Xpert Meter Web Interface, Step 1: Getting Started with

the New UI

The New Power Xpert Meter Web Interface, Step 4: Accessing the Meter

with a Tablet

The New Power Xpert Meter Web Interface, Step 2: Navigating the New

UI

Power Xpert Meters

Specifications and datasheets

Eaton Power Xpert Meter 4000/6000/8000 power quality and energy

meters

White papers

Next generation power quality meters white paper

I/O capability

Synchronize Demand Window Pulse Input

Load Shedding

Prog. Pulse Output --Wh, Varh, Vah

Programmable Relay Outputs -5

Programmable Discrete Inputs - 8

KYZ output

Voltage Disturbance Trip

ANSI % revenue accuracy

C12.20 (0.2)

Modification 3

I/O option card (8 digital inputs, 2 solid state outputs, 3 relay

outputs)

Power supply voltage

100-240 V, 110-250 Vdc

Eaton Corporation plc

Eaton House

30 Pembroke Road

Dublin 4, Ireland

Eaton is a registered trademark.

All other trademarks are

© 2023 Eaton. All Rights property of their respective

Reserved. owners.

/socialmedia