最新消息: USBMI致力于为网友们分享Windows、安卓、IOS等主流手机系统相关的资讯以及评测、同时提供相关教程、应用、软件下载等服务。

莫萨EDS-728 系列 24+4G 层2可扩展Managed Ethernet交换机特点与优势说

IT圈 admin 18浏览 0评论

2024年10月27日发(作者:訾升荣)

EDS-728Series

24+4G-portLayer2GigabitmodularmanagedEthernetswitches

FeatureandBenefitsFeaturesandBenefits

4Gigabitplus24FastEthernetportsforcopperandfiber

TurboRingandTurboChain(recoverytime<20ms@250switches),

1

RSTP/

STP,andMSTPfornetworkredundancy

TACACS+,SNMPv3,IEEE802.1X,HTTPS,andSSHtoenhancenetwork

security

Easynetworkmanagementbywebbrowser,CLI,Telnet/serialconsole,

Windowsutility,andABC-01

SupportsMXstudioforeasy,visualizedindustrialnetworkmanagement

Certifications

Introduction

TheEDS-728Seriesfeaturesaversatilemodulardesignthatallowsdifferentcombinationsoffiberandcoppermodules,creatingawidearrayof

EDS-728SeriesisspeciallydesignedforredundantGigabitnetworkbackbonesandusesamodularconfigurationtoprovideahighdegreeof

flexibilityfornetworkexpansion.

Topnetworkperformance,security,andreliabilityareassu-

728Seriesalsofeaturesindustrial-gradeconstruction,aconsoleportforautomaticconfigurationbackup,andanangledLEDtroubleshooting

panelthatcanbeconvenientlyviewedfrombothhorizontalandverticalorientations.

AdditionalFeaturesandBenefits

•Commandlineinterface(CLI)forquicklyconfiguringmajor

managedfunctions

•SupportsadvancedVLANcapabilitywithQ-in-Qtagging

•Software-basedIEEE1588PTPv2(PrecisionTimeProtocol)for

timesynchronizationofnetworks

•DHCPOption82forIPaddressassignmentwithdifferentpolicies

•SupportsEtherNet/IPandModbusTCPprotocolsfordevice

managementandmonitoring

•CompatiblewithPROFINETprotocolfortransparentdata

transmission

•IGMPsnoopingandGMRPforfilteringmulticasttraffic

•IEEE802.1QVLANandGVRPprotocoltoeasenetworkplanning

•QoS(IEEE802.1p/1QandTOS/DiffServ)toincreasedeterminism

PortTrunkingforoptimumbandwidthutilization

SNMPv1/v2c/v3fordifferentlevelsofnetworkmanagement

RMONforproactiveandefficientnetworkmonitoring

Bandwidthmanagementtopreventunpredictablenetworkstatus

LockportfunctionforblockingunauthorizedaccessbasedonMAC

address

Portmirroringforonlinedebugging

Automaticwarningbyexceptionthroughemailandrelayoutput

DigitalinputsforintegratingsensorsandalarmswithIPnetworks

Redundant,dualDCpowerinputs

ConfigurablebyWebbrowser,Telnet/serialconsole,CLI,Windows

utility,andABC-01automaticbackupconfigurator

Specifications

Input/OutputInterface

AlarmContactChannels

DigitalInputChannels

DigitalInputs

2,Relayoutputwithcurrentcarryingcapacityof1A@24VDC

2

+13to+30Vforstate1

-30to+3Vforstate0

urrent:8mA

tEthernetrecoverytime<50ms

1

EthernetInterface

Module6slotsforanycombinationof4-portinterfacemodules,10/100BaseT(X)or100BaseFX;

2slotsforanycombinationof2-portinterfacemodules,10/100/1000BaseT(X)or

1000BaseSFP

IEEE802.1D-2004forSpanningTreeProtocol

IEEE802.1pforClassofService

IEEE802.1QforVLANTagging

IEEE802.1sforMultipleSpanningTreeProtocol

IEEE802.1wforRapidSpanningTreeProtocol

IEEE802.1Xforauthentication

IEEE802.3for10BaseT

IEEE802.3abfor1000BaseT(X)

IEEE802.3adforPortTrunkwithLACP

IEEE802.3ufor100BaseT(X)and100BaseFX

IEEE802.3xforflowcontrol

IEEE802.3zfor1000BaseX

Standards

EthernetSoftwareFeatures

Filter

IndustrialProtocols

Management

GMRP,GVRP,IGMPv1/v2,QinQVLAN,802.1QVLAN,VLANunaware

EtherNet/IP,ModbusTCP

BackPressureFlowControl,BOOTP,DDM,DHCPOption66/67/82,DHCPServer/

Client,Flowcontrol,IPv4,LLDP,PortMirror,RARP,RMON,SMTP,SNMPInform,

SNMPv1/v2c/v3,Syslog,Telnet,TFTP

BridgeMIB,Ethernet-likeMIB,MIB-II,P-BRIDGEMIB,Q-BRIDGEMIB,RMONMIB

Groups1,2,3,9,RSTPMIB

LinkAggregation,MSTP,RSTP,STP,TurboChain,TurboRingv1/v2

Broadcaststormprotection,HTTPS/SSL,PortLock,RADIUS,SSH,TACACS+

NTPServer/Client,SNTP,IEEE1588v2PTP(software-based)

MIB

RedundancyProtocols

Security

TimeManagement

SwitchProperties

IGMPGroups

MACTableSize

s

PacketBufferSize

PriorityQueues

VLANIDRange

256

16K

64

32Mbits

4

VID1to4094

SerialInterface

ConsolePortRS-232(TxD,RxD,GND),8-pinRJ45(115200,n,8,1)

PowerParameters

Connection

InputCurrent

InputVoltage

OperatingVoltage

OverloadCurrentProtection

ReversePolarityProtection

2removable6-contactterminalblock(s)

0.82A@24VDC

24VDC,Redundantdualinputs

12to45VDC

Supported

Supported

2

PhysicalCharacteristics

IPRating

Dimensions

Weight

Installation

IP30

362.4x142.5x128mm(14.27x5.61x5.04in)

1950g(4.30lb)

DIN-railmounting,Wallmounting(withoptionalkit)

EnvironmentalLimits

OperatingTemperature

StorageTemperature(packageincluded)

AmbientRelativeHumidity

0to60°C(32to140°F)

-40to85°C(-40to185°F)

5to95%(non-condensing)

StandardsandCertifications

Freefall

EMC

EMI

EMS

IEC60068-2-32

EN55032/24

CISPR32,FCCPart15BClassA

IEC61000-4-2ESD:Contact:6kV;Air:8kV

IEC61000-4-3RS:80MHzto1GHz:10V/m

IEC61000-4-4EFT:Power:4kV;Signal:2kV

IEC61000-4-5Surge:Power:2kV;Signal:1kV

IEC61000-4-6CS:10V

IEC61000-4-8PFMF

ABS,DNV-GL,LR,NK

EN60950-1,UL508,UL60950-1,CSAC22.2No.60950-1

IEC60068-2-27

IEC60068-2-6

Maritime

Safety

Shock

Vibration

MTBF

Time

Standards

191,203hrs

TelcordiaSR332

Warranty

WarrantyPeriod

Details

5years

/warranty

PackageContents

Device

Cable

Documentation

1xEDS-728Seriesswitch

1xRJ45-to-DB9consolecable

1xdocumentandsoftwareCD

1xproductcertificatesofqualityinspection,SimplifiedChinese

1xproductnotice,SimplifiedChinese

1xquickinstallationguide

1xwarrantycard

SFPmodulesand/ormodulesfromtheIMModuleSeriesneedtobepurchased

separatelyforusewiththisproduct.

Note

3

Dimensions

OrderingInformation

ModelNameLayer

TotalNo.

ofPorts

28

IM-2GSeriesModule10/100/

1000BaseT(X)or1000BaseSFP

2slotsforupto410/100/1000BaseT(X)

or1000BaseSFPports

IMSeriesModule10/100BaseT(X)

and/or100BaseFX

6slotsforupto2410/100BaseT(X)

and/or100BaseFXports

OperatingTemp.

EDS-72810G20to60°C

Accessories(soldseparately)

IMModuleSeries

IM-1LSC/3TX

IM-2GSFP

IM-2GTX

IM-2MSC/2TX

IM-2MST/2TX

IM-2SSC/2TX

IM-4MSC

IM-4MST

IM-4SSC

IM-4TX

FastEthernetinterfaceACmodulewith310/100BaseT(X)ports,1100BaseFXsingle-modeportwith

SCconnectorfor80kmtransmission,0to60°Coperatingtemperature

GigabitEthernetinterfacemodulewith21000BaseSFPslots,0to60°Coperatingtemperature

GigabitEthernetinterfacemodulewith210/100/1000BaseT(X)ports,0to60°Coperatingtemperature

FastEthernetinterfacemodulewith210/100BaseT(X)ports,2100BaseFXmulti-modeportswithSC

connector,0to60°Coperatingtemperature

FastEthernetinterfacemodulewith210/100BaseT(X)ports,2100BaseFXmulti-modeportswithST

connectors,0to60°Coperatingtemperature

FastEthernetinterfacemodulewith210/100BaseT(X)ports,2100BaseFXsingle-modeportswithSC

connectors,0to60°Coperatingtemperature

FastEthernetinterfacemodulewith4100BaseFXmulti-modeportswithSCconnector,0to60°C

operatingtemperature

FastEthernetinterfacemodulewith4100BaseFXmulti-modeportswithSTconnectors,0to60°C

operatingtemperature

FastEthernetinterfacemodulewith4100BaseFXsingle-modeportswithSCconnector,0to60°C

operatingtemperature

FastEthernetinterfacemodulewith410/100BaseT(X)ports,0to60°Coperatingtemperature

StorageKits

ABC-01ConfigurationbackupandrestorationtoolformanagedEthernetswitchesandAWKSerieswireless

APs/bridges/clients,0to60°Coperatingtemperature

SFPModules

SFP-1G10ALC

SFP-1G10ALC-T

SFP-1G10BLC

SFP-1G10BLC-T

WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor10kmtransmission;TX

1310nm,RX1550nm,0to60°Coperatingtemperature

WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor10kmtransmission;TX

1310nm,RX1550nm,-40to85°Coperatingtemperature

WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor10kmtransmission;TX

1550nm,RX1310nm,0to60°Coperatingtemperature

WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor10kmtransmission;TX

1550nm,RX1310nm,-40to85°Coperatingtemperature

4

SFP-1G20ALC

SFP-1G20ALC-T

SFP-1G20BLC

SFP-1G20BLC-T

SFP-1G40ALC

SFP-1G40ALC-T

SFP-1G40BLC

SFP-1G40BLC-T

SFP-1GEZXLC

SFP-1GEZXLC-120

SFP-1GLHLC

SFP-1GLHLC-T

SFP-1GLHXLC

SFP-1GLHXLC-T

SFP-1GLSXLC

SFP-1GLSXLC-T

SFP-1GLXLC

SFP-1GLXLC-T

SFP-1GSXLC

SFP-1GSXLC-T

SFP-1GZXLC

SFP-1GZXLC-T

WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor20kmtransmission;TX

1310nm,RX1550nm,0to60°Coperatingtemperature

WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor20kmtransmission;TX

1310nm,RX1550nm,-40to85°Coperatingtemperature

WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor20kmtransmission;TX

1550nm,RX1310nm,0to60°Coperatingtemperature

WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor20kmtransmission;TX

1550nm,RX1310nm,-40to85°Coperatingtemperature

WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor40kmtransmission;TX

1310nm,RX1550nm,0to60°Coperatingtemperature

WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor40kmtransmission;TX

1310nm,RX1550nm,-40to85°Coperatingtemperature

WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor40kmtransmission;TX

1550nm,RX1310nm,0to60°Coperatingtemperature

WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor40kmtransmission;TX

1550nm,RX1310nm,-40to85°Coperatingtemperature

SFPmodulewith11000BaseEZXportwithLCconnectorfor110kmtransmission,0to60°Coperating

temperature

SFPmodulewith11000BaseEZXportwithLCconnectorfor120kmtransmission,0to60°Coperating

temperature

SFPmodulewith11000BaseLHportwithLCconnectorfor30kmtransmission,0to60°Coperating

temperature

SFPmodulewith11000BaseLHportwithLCconnectorfor30kmtransmission,-40to85°Coperating

temperature

SFPmodulewith11000BaseLHXportwithLCconnectorfor40kmtransmission,0to60°Coperating

temperature

SFPmodulewith11000BaseLHXportwithLCconnectorfor40kmtransmission,-40to85°C

operatingtemperature

SFPmodulewith11000BaseLSXportwithLCconnectorfor1km/2kmtransmission,0to60°C

operatingtemperature

SFPmodulewith11000BaseLSXportwithLCconnectorfor1km/2kmtransmission,-40to85°C

operatingtemperature

SFPmodulewith11000BaseLXportwithLCconnectorfor10kmtransmission,0to60°Coperating

temperature

SFPmodulewith11000BaseLXportwithLCconnectorfor10kmtransmission,-40to85°Coperating

temperature

SFPmodulewith11000BaseSXportwithLCconnectorfor300m/550mtransmission,0to60°C

operatingtemperature

SFPmodulewith11000BaseSXportwithLCconnectorfor300m/550mtransmission,-40to85°C

operatingtemperature

SFPmodulewith11000BaseZXportwithLCconnectorfor80kmtransmission,0to60°Coperating

temperature

SFPmodulewith11000BaseZXportwithLCconnectorfor80kmtransmission,-40to85°Coperating

temperature

PowerSupplies

DR-120-24

DR-4524

DR-75-24

MDR-40-24

MDR-60-24

120W/2.5ADIN-rail24VDCpowersupplywithuniversal88to132VACor176to264VACinputby

switch,or248to370VDCinput,-10to60°Coperatingtemperature

45W/2ADIN-rail24VDCpowersupplywithuniversal85to264VACor120to370VDCinput,-10to50°

Coperatingtemperature

75W/3.2ADIN-rail24VDCpowersupplywithuniversal85to264VACor120to370VDCinput,-10to

60°Coperatingtemperature

DIN-rail24VDCpowersupplywith40W/1.7A,85to264VAC,or120to370VDCinput,-20to70°C

operatingtemperature

DIN-rail24VDCpowersupplywith60W/2.5A,85to264VAC,or120to370VDCinput,-20to70°C

operatingtemperature

5

Software

MXview-50

MXview-100

MXview-250

MXview-500

MXview-1000

MXview-2000

MXviewUpgrade-50

Industrialnetworkmanagementsoftwarewithalicensefor50nodes(byIPaddress)

Industrialnetworkmanagementsoftwarewithalicensefor100nodes(byIPaddress)

Industrialnetworkmanagementsoftwarewithalicensefor250nodes(byIPaddress)

Industrialnetworkmanagementsoftwarewithalicensefor500nodes(byIPaddress)

Industrialnetworkmanagementsoftwarewithalicensefor1000nodes(byIPaddress)

Industrialnetworkmanagementsoftwarewithalicensefor2000nodes(byIPaddress)

LicenseexpansionofMXviewindustrialnetworkmanagementsoftwareby50nodes(byIPaddress)

Rack-MountingKits

RK-4U19-inchrack-mountingkit

Wall-MountingKits

WK-32Wall-mountingkit,2plates,6screws,30.3x140x12.3mm

©dNov25,2020.

Thisdocumentandanyportionthereofmaynotbereproducedorusedinanymannerwhatsoeverwithouttheexpresswrittenpermissionof

urwebsiteforthemostup-to-dateproductinformation.

6

2024年10月27日发(作者:訾升荣)

EDS-728Series

24+4G-portLayer2GigabitmodularmanagedEthernetswitches

FeatureandBenefitsFeaturesandBenefits

4Gigabitplus24FastEthernetportsforcopperandfiber

TurboRingandTurboChain(recoverytime<20ms@250switches),

1

RSTP/

STP,andMSTPfornetworkredundancy

TACACS+,SNMPv3,IEEE802.1X,HTTPS,andSSHtoenhancenetwork

security

Easynetworkmanagementbywebbrowser,CLI,Telnet/serialconsole,

Windowsutility,andABC-01

SupportsMXstudioforeasy,visualizedindustrialnetworkmanagement

Certifications

Introduction

TheEDS-728Seriesfeaturesaversatilemodulardesignthatallowsdifferentcombinationsoffiberandcoppermodules,creatingawidearrayof

EDS-728SeriesisspeciallydesignedforredundantGigabitnetworkbackbonesandusesamodularconfigurationtoprovideahighdegreeof

flexibilityfornetworkexpansion.

Topnetworkperformance,security,andreliabilityareassu-

728Seriesalsofeaturesindustrial-gradeconstruction,aconsoleportforautomaticconfigurationbackup,andanangledLEDtroubleshooting

panelthatcanbeconvenientlyviewedfrombothhorizontalandverticalorientations.

AdditionalFeaturesandBenefits

•Commandlineinterface(CLI)forquicklyconfiguringmajor

managedfunctions

•SupportsadvancedVLANcapabilitywithQ-in-Qtagging

•Software-basedIEEE1588PTPv2(PrecisionTimeProtocol)for

timesynchronizationofnetworks

•DHCPOption82forIPaddressassignmentwithdifferentpolicies

•SupportsEtherNet/IPandModbusTCPprotocolsfordevice

managementandmonitoring

•CompatiblewithPROFINETprotocolfortransparentdata

transmission

•IGMPsnoopingandGMRPforfilteringmulticasttraffic

•IEEE802.1QVLANandGVRPprotocoltoeasenetworkplanning

•QoS(IEEE802.1p/1QandTOS/DiffServ)toincreasedeterminism

PortTrunkingforoptimumbandwidthutilization

SNMPv1/v2c/v3fordifferentlevelsofnetworkmanagement

RMONforproactiveandefficientnetworkmonitoring

Bandwidthmanagementtopreventunpredictablenetworkstatus

LockportfunctionforblockingunauthorizedaccessbasedonMAC

address

Portmirroringforonlinedebugging

Automaticwarningbyexceptionthroughemailandrelayoutput

DigitalinputsforintegratingsensorsandalarmswithIPnetworks

Redundant,dualDCpowerinputs

ConfigurablebyWebbrowser,Telnet/serialconsole,CLI,Windows

utility,andABC-01automaticbackupconfigurator

Specifications

Input/OutputInterface

AlarmContactChannels

DigitalInputChannels

DigitalInputs

2,Relayoutputwithcurrentcarryingcapacityof1A@24VDC

2

+13to+30Vforstate1

-30to+3Vforstate0

urrent:8mA

tEthernetrecoverytime<50ms

1

EthernetInterface

Module6slotsforanycombinationof4-portinterfacemodules,10/100BaseT(X)or100BaseFX;

2slotsforanycombinationof2-portinterfacemodules,10/100/1000BaseT(X)or

1000BaseSFP

IEEE802.1D-2004forSpanningTreeProtocol

IEEE802.1pforClassofService

IEEE802.1QforVLANTagging

IEEE802.1sforMultipleSpanningTreeProtocol

IEEE802.1wforRapidSpanningTreeProtocol

IEEE802.1Xforauthentication

IEEE802.3for10BaseT

IEEE802.3abfor1000BaseT(X)

IEEE802.3adforPortTrunkwithLACP

IEEE802.3ufor100BaseT(X)and100BaseFX

IEEE802.3xforflowcontrol

IEEE802.3zfor1000BaseX

Standards

EthernetSoftwareFeatures

Filter

IndustrialProtocols

Management

GMRP,GVRP,IGMPv1/v2,QinQVLAN,802.1QVLAN,VLANunaware

EtherNet/IP,ModbusTCP

BackPressureFlowControl,BOOTP,DDM,DHCPOption66/67/82,DHCPServer/

Client,Flowcontrol,IPv4,LLDP,PortMirror,RARP,RMON,SMTP,SNMPInform,

SNMPv1/v2c/v3,Syslog,Telnet,TFTP

BridgeMIB,Ethernet-likeMIB,MIB-II,P-BRIDGEMIB,Q-BRIDGEMIB,RMONMIB

Groups1,2,3,9,RSTPMIB

LinkAggregation,MSTP,RSTP,STP,TurboChain,TurboRingv1/v2

Broadcaststormprotection,HTTPS/SSL,PortLock,RADIUS,SSH,TACACS+

NTPServer/Client,SNTP,IEEE1588v2PTP(software-based)

MIB

RedundancyProtocols

Security

TimeManagement

SwitchProperties

IGMPGroups

MACTableSize

s

PacketBufferSize

PriorityQueues

VLANIDRange

256

16K

64

32Mbits

4

VID1to4094

SerialInterface

ConsolePortRS-232(TxD,RxD,GND),8-pinRJ45(115200,n,8,1)

PowerParameters

Connection

InputCurrent

InputVoltage

OperatingVoltage

OverloadCurrentProtection

ReversePolarityProtection

2removable6-contactterminalblock(s)

0.82A@24VDC

24VDC,Redundantdualinputs

12to45VDC

Supported

Supported

2

PhysicalCharacteristics

IPRating

Dimensions

Weight

Installation

IP30

362.4x142.5x128mm(14.27x5.61x5.04in)

1950g(4.30lb)

DIN-railmounting,Wallmounting(withoptionalkit)

EnvironmentalLimits

OperatingTemperature

StorageTemperature(packageincluded)

AmbientRelativeHumidity

0to60°C(32to140°F)

-40to85°C(-40to185°F)

5to95%(non-condensing)

StandardsandCertifications

Freefall

EMC

EMI

EMS

IEC60068-2-32

EN55032/24

CISPR32,FCCPart15BClassA

IEC61000-4-2ESD:Contact:6kV;Air:8kV

IEC61000-4-3RS:80MHzto1GHz:10V/m

IEC61000-4-4EFT:Power:4kV;Signal:2kV

IEC61000-4-5Surge:Power:2kV;Signal:1kV

IEC61000-4-6CS:10V

IEC61000-4-8PFMF

ABS,DNV-GL,LR,NK

EN60950-1,UL508,UL60950-1,CSAC22.2No.60950-1

IEC60068-2-27

IEC60068-2-6

Maritime

Safety

Shock

Vibration

MTBF

Time

Standards

191,203hrs

TelcordiaSR332

Warranty

WarrantyPeriod

Details

5years

/warranty

PackageContents

Device

Cable

Documentation

1xEDS-728Seriesswitch

1xRJ45-to-DB9consolecable

1xdocumentandsoftwareCD

1xproductcertificatesofqualityinspection,SimplifiedChinese

1xproductnotice,SimplifiedChinese

1xquickinstallationguide

1xwarrantycard

SFPmodulesand/ormodulesfromtheIMModuleSeriesneedtobepurchased

separatelyforusewiththisproduct.

Note

3

Dimensions

OrderingInformation

ModelNameLayer

TotalNo.

ofPorts

28

IM-2GSeriesModule10/100/

1000BaseT(X)or1000BaseSFP

2slotsforupto410/100/1000BaseT(X)

or1000BaseSFPports

IMSeriesModule10/100BaseT(X)

and/or100BaseFX

6slotsforupto2410/100BaseT(X)

and/or100BaseFXports

OperatingTemp.

EDS-72810G20to60°C

Accessories(soldseparately)

IMModuleSeries

IM-1LSC/3TX

IM-2GSFP

IM-2GTX

IM-2MSC/2TX

IM-2MST/2TX

IM-2SSC/2TX

IM-4MSC

IM-4MST

IM-4SSC

IM-4TX

FastEthernetinterfaceACmodulewith310/100BaseT(X)ports,1100BaseFXsingle-modeportwith

SCconnectorfor80kmtransmission,0to60°Coperatingtemperature

GigabitEthernetinterfacemodulewith21000BaseSFPslots,0to60°Coperatingtemperature

GigabitEthernetinterfacemodulewith210/100/1000BaseT(X)ports,0to60°Coperatingtemperature

FastEthernetinterfacemodulewith210/100BaseT(X)ports,2100BaseFXmulti-modeportswithSC

connector,0to60°Coperatingtemperature

FastEthernetinterfacemodulewith210/100BaseT(X)ports,2100BaseFXmulti-modeportswithST

connectors,0to60°Coperatingtemperature

FastEthernetinterfacemodulewith210/100BaseT(X)ports,2100BaseFXsingle-modeportswithSC

connectors,0to60°Coperatingtemperature

FastEthernetinterfacemodulewith4100BaseFXmulti-modeportswithSCconnector,0to60°C

operatingtemperature

FastEthernetinterfacemodulewith4100BaseFXmulti-modeportswithSTconnectors,0to60°C

operatingtemperature

FastEthernetinterfacemodulewith4100BaseFXsingle-modeportswithSCconnector,0to60°C

operatingtemperature

FastEthernetinterfacemodulewith410/100BaseT(X)ports,0to60°Coperatingtemperature

StorageKits

ABC-01ConfigurationbackupandrestorationtoolformanagedEthernetswitchesandAWKSerieswireless

APs/bridges/clients,0to60°Coperatingtemperature

SFPModules

SFP-1G10ALC

SFP-1G10ALC-T

SFP-1G10BLC

SFP-1G10BLC-T

WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor10kmtransmission;TX

1310nm,RX1550nm,0to60°Coperatingtemperature

WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor10kmtransmission;TX

1310nm,RX1550nm,-40to85°Coperatingtemperature

WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor10kmtransmission;TX

1550nm,RX1310nm,0to60°Coperatingtemperature

WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor10kmtransmission;TX

1550nm,RX1310nm,-40to85°Coperatingtemperature

4

SFP-1G20ALC

SFP-1G20ALC-T

SFP-1G20BLC

SFP-1G20BLC-T

SFP-1G40ALC

SFP-1G40ALC-T

SFP-1G40BLC

SFP-1G40BLC-T

SFP-1GEZXLC

SFP-1GEZXLC-120

SFP-1GLHLC

SFP-1GLHLC-T

SFP-1GLHXLC

SFP-1GLHXLC-T

SFP-1GLSXLC

SFP-1GLSXLC-T

SFP-1GLXLC

SFP-1GLXLC-T

SFP-1GSXLC

SFP-1GSXLC-T

SFP-1GZXLC

SFP-1GZXLC-T

WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor20kmtransmission;TX

1310nm,RX1550nm,0to60°Coperatingtemperature

WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor20kmtransmission;TX

1310nm,RX1550nm,-40to85°Coperatingtemperature

WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor20kmtransmission;TX

1550nm,RX1310nm,0to60°Coperatingtemperature

WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor20kmtransmission;TX

1550nm,RX1310nm,-40to85°Coperatingtemperature

WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor40kmtransmission;TX

1310nm,RX1550nm,0to60°Coperatingtemperature

WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor40kmtransmission;TX

1310nm,RX1550nm,-40to85°Coperatingtemperature

WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor40kmtransmission;TX

1550nm,RX1310nm,0to60°Coperatingtemperature

WDM-type(BiDi)SFPmodulewith11000BaseSFPportwithLCconnectorfor40kmtransmission;TX

1550nm,RX1310nm,-40to85°Coperatingtemperature

SFPmodulewith11000BaseEZXportwithLCconnectorfor110kmtransmission,0to60°Coperating

temperature

SFPmodulewith11000BaseEZXportwithLCconnectorfor120kmtransmission,0to60°Coperating

temperature

SFPmodulewith11000BaseLHportwithLCconnectorfor30kmtransmission,0to60°Coperating

temperature

SFPmodulewith11000BaseLHportwithLCconnectorfor30kmtransmission,-40to85°Coperating

temperature

SFPmodulewith11000BaseLHXportwithLCconnectorfor40kmtransmission,0to60°Coperating

temperature

SFPmodulewith11000BaseLHXportwithLCconnectorfor40kmtransmission,-40to85°C

operatingtemperature

SFPmodulewith11000BaseLSXportwithLCconnectorfor1km/2kmtransmission,0to60°C

operatingtemperature

SFPmodulewith11000BaseLSXportwithLCconnectorfor1km/2kmtransmission,-40to85°C

operatingtemperature

SFPmodulewith11000BaseLXportwithLCconnectorfor10kmtransmission,0to60°Coperating

temperature

SFPmodulewith11000BaseLXportwithLCconnectorfor10kmtransmission,-40to85°Coperating

temperature

SFPmodulewith11000BaseSXportwithLCconnectorfor300m/550mtransmission,0to60°C

operatingtemperature

SFPmodulewith11000BaseSXportwithLCconnectorfor300m/550mtransmission,-40to85°C

operatingtemperature

SFPmodulewith11000BaseZXportwithLCconnectorfor80kmtransmission,0to60°Coperating

temperature

SFPmodulewith11000BaseZXportwithLCconnectorfor80kmtransmission,-40to85°Coperating

temperature

PowerSupplies

DR-120-24

DR-4524

DR-75-24

MDR-40-24

MDR-60-24

120W/2.5ADIN-rail24VDCpowersupplywithuniversal88to132VACor176to264VACinputby

switch,or248to370VDCinput,-10to60°Coperatingtemperature

45W/2ADIN-rail24VDCpowersupplywithuniversal85to264VACor120to370VDCinput,-10to50°

Coperatingtemperature

75W/3.2ADIN-rail24VDCpowersupplywithuniversal85to264VACor120to370VDCinput,-10to

60°Coperatingtemperature

DIN-rail24VDCpowersupplywith40W/1.7A,85to264VAC,or120to370VDCinput,-20to70°C

operatingtemperature

DIN-rail24VDCpowersupplywith60W/2.5A,85to264VAC,or120to370VDCinput,-20to70°C

operatingtemperature

5

Software

MXview-50

MXview-100

MXview-250

MXview-500

MXview-1000

MXview-2000

MXviewUpgrade-50

Industrialnetworkmanagementsoftwarewithalicensefor50nodes(byIPaddress)

Industrialnetworkmanagementsoftwarewithalicensefor100nodes(byIPaddress)

Industrialnetworkmanagementsoftwarewithalicensefor250nodes(byIPaddress)

Industrialnetworkmanagementsoftwarewithalicensefor500nodes(byIPaddress)

Industrialnetworkmanagementsoftwarewithalicensefor1000nodes(byIPaddress)

Industrialnetworkmanagementsoftwarewithalicensefor2000nodes(byIPaddress)

LicenseexpansionofMXviewindustrialnetworkmanagementsoftwareby50nodes(byIPaddress)

Rack-MountingKits

RK-4U19-inchrack-mountingkit

Wall-MountingKits

WK-32Wall-mountingkit,2plates,6screws,30.3x140x12.3mm

©dNov25,2020.

Thisdocumentandanyportionthereofmaynotbereproducedorusedinanymannerwhatsoeverwithouttheexpresswrittenpermissionof

urwebsiteforthemostup-to-dateproductinformation.

6

发布评论

评论列表 (0)

  1. 暂无评论