三星18650 2200mAh规格书

IT圈 admin 31浏览 0评论

2023年12月2日发(作者:谭红豆)

SAMSUNG SDI Confidential Proprietary.

Spec. No.

ICR18650-22FM Version No. 2.0

SPECIFICATION OF PRODUCT

for Lithium-ion Rechargeable Cell

Model : ICR18650-22FM

Aug, 2008

Samsung SDI Co., Ltd.

Battery Business Division

SAMSUNG SDI Confidential Proprietary.

Spec. No.

ICR18650-22FM Version No. 2.0

History of Revisions

Date

()

08.07.01

08.08.11

Rev. No

Ver. 1.0

Ver. 2.0

Initial

Rate charge/discharge SPEC addition

Description

Approved by

QA Development

Sujin han JeongSoon Shin

Sujin han DockYoung Youn

Proposed

by

1

Samsung SDI Battery Business Division. SAMSUNG SDI Confidential Proprietary.

Spec. No.

ICR18650-22FM Version No. 2.0

1. Scope

This product specification has been prepared to specify the rechargeable lithium-ion cell

('cell') to be supplied to the customer by Samsung SDI Co., Ltd.

2. Description and Model

2.1 Description Cell (lithium-ion rechargeable cell)

2.2 Model ICR18650-22FM

3. Nominal Specifications

Item

3.1 Nominal Capacity

3.2 Charging Voltage

3.3 Nominal Voltage

3.4 Charging Method

3.5 Charging Current

3.6 Charging Time

3.7 Max. Charge Current

3.8 Max. Discharge Current

3.9 Discharge Cut-off Voltage

3.10 Cell Weight

3.11 Cell Dimension

3.12 Operating Temperature

3.13 Storage Temperature

Specification

2200mAh (0.2C, 2.75V discharge)

4.2V±0.05 V

3.6V

CC-CV

(constant voltage with limited current)

Standard charge: 1100mA

Rapid charge : 2200mA

Standard charge : 3hours

Rapid charge : 2.5hours

2200mA

4400mA

2.75V

44.5g max

Diameter(max.) : Φ18.4 mm

Height : 65mm max

Charge : 0 to 45℃

Discharge: -20 to 60℃

1 year : -20~25℃(1*)

3 months : -20~45℃(1*)

1 month : -20~60℃(1*)

Note (1): If the cell is kept as ex-factory status(50% of charge),

the capacity recovery rate is more than 80%.

2

Samsung SDI Battery Business Division. SAMSUNG SDI Confidential Proprietary.

Spec. No.

ICR18650-22FM Version No. 2.0

4. Outline Dimensions

See the attachment(Fig. 1)

5. Appearance

There shall be no such defects as scratch, rust, discoloration, leakage which

may adversely affect commercial value of the cell.

6. Standard Test Conditions

6.1 Environmental Conditions

Unless otherwise specified, all tests stated in this specification are

conducted at temperature 25±5℃ and humidity 65±20%.

6.2 Measuring Equipment

(1) Ammeter and Voltmeter

The ammeter and voltmeter should have an accuracy of the grade 0.5 or higher.

(2) Slide caliper

The slide caliper should have 0.05 mm scale.

(3) Impedance meter

The impedance meter with AC 1kHz should be used.

7. Characteristics

7.1 Standard Charge

This "Standard Charge" means charging the cell with charge current

1100mA and constant voltage 4.2V at 25℃ for 3hours.

7.2 Standard Discharge Capacity

The standard discharge capacity is the initial discharge capacity of the cell, which is

measured with discharge current of 440mA with 2.75V cut-off at 25℃ within 1 hour

after the Standard charge.

Standard Discharge Capacity ≥ 2150mAh

7.3 Initial internal impedance

Initial internal impedance measured at AC 1kHz after Standard charge.

Initial internal impedance ≤ 100mΩ

7.4 Temperature Dependence of Discharge Capacity

Discharge capacity comparison at each temperature, measured with discharge

constant current 1100mA and 2.75V cut-off with follow temperature after the standard

charging at 25℃.

Charge Temperature

25℃

Relative Capacity

-10℃

50%

3

Discharge temperature

0℃

70%

25℃

100%

45℃

100%

Samsung SDI Battery Business Division. SAMSUNG SDI Confidential Proprietary.

Spec. No.

ICR18650-22FM Version No. 2.0

Note: If charge temperature and discharge temperature is not the same,

the interval for temperature change is 3 hours.

Percentage as an index of the Standard discharge capacity(=2150mAh) is 100%.

7.5 Temperature Dependence of Charge Capacity

Capacity comparison at each temperature, measured with discharge

constant current 1000mA and 2.75V cut-off at 25℃ after the Standard charge is

as follow temperature.

Relative Capacity

Charge temperature

0℃

80%

25℃

100%

45℃

100%

Discharge temperature

25℃

Note: If charge temperature and discharge temperature is not the same,

the interval for temperature change is 3 hours.

Percentage as an index of the Standard discharge capacity(=2150mAh) is 100%.

7.6 Charge Rate Capabilities

Discharge capacity is measured with constant current 440mA and 2.75V cut-off

after the cell is charged with 4.2V as follows.

Current

Cut-off

Relative

Capacity

Note: Percentage as an index of the capacity at 25℃(=2150mAh) is 100%.

7.7 Discharge Rate Capabilities

Discharge capacity is measured with the various currents in under table and 2.75V

cut-off after the standard charge.

Discharge Condition

0.2C 0.5C 1.0C 2.0C

Current

(440mA) (1100mA) (2200mA) (4400mA)

Relative

100% 95% 90% 80%

Capacity

Note: Percentage as an index of the capacity at 25℃(=2150mAh) is 100%.

4

0.2C

(440mA)

7h or 0.05C

100%

Charge Condition

0.5C

(1100mA)

3h or 0.05C

95%

1.0C

(2200mA)

2.5h or 0.05C

90%

Samsung SDI Battery Business Division. SAMSUNG SDI Confidential Proprietary.

Spec. No. ICR18650-22FM Version No. 2.0

7.8 Cycle Life

Each cycle is an interval between the charge (charge current 1760mA) and the

discharge (discharge current 2200mA) with 2.75V cut-off. Capacity

after 299cycles and plus 1 day, measured under the same condition in 7.2

Capacity ≥ 1500mAh

7.9 Storage Characteristics

Capacity after storage for 30days at 25℃ after the Standard charged,

measured with discharge current 1100mA with 2.75V cut-off at 25℃.

Capacity retention(after the storage) ≥ 1720mAh

7.10 Status of the cell as of ex-factory

The cell should be shipped in 50% charged state.

8. Mechanical Characteristics

8.1 Drop Test

Test method: Cell(as of shipment or full charged) drop onto the oak-board

(thickness:≥30mm) from 4feet height at a random direction 6 times.

Criteria: No leakage

8.2 Vibration Test

Test method: Cell(as of shipment) is vibrated along 2 mutually

perpendicular axes with total excursion of 1.6mm and with

frequency cycling between 10Hz and 55Hz by 1Hz/min.

Criteria: No leakage

9. Safety

10.1 Overcharge Test

Test method: To charge the standard charged cell with 12V and 2200mA at 25℃

for 2.5 hours.

Criteria: No fire, and no explosion.

10.2 External Short-circuit Test

Test method: To short-circuit the standard charged cell by connecting positive and

negative terminal by less than 50mΩwire for 3 hours.

Criteria: No fire, and no explosion.

10.3 Reverse Charge Test

Test method: To charge reversely the standard charged cell with charge current

2200mA for 2.5 hours.

Criteria: No fire, and no explosion.

5

Samsung SDI Battery Business Division. SAMSUNG SDI Confidential Proprietary.

Spec. No. ICR18650-22FM Version No. 2.0

10.4 Heating Test

Test method: To heat the standard charged cell at heating rate of 5℃ per minute up to

130℃ and keep the cell in oven for 60 minutes.

Criteria: No fire, and no explosion.

10. Warranty

Samsung SDI will be responsible for replacing the cell against defects or poor workmanship

for 15month from the date of shipping. Any other problems caused by malfunction of the

equipment or unsuitable use of the cell are not under this warranty.

The warranty set forth in proper use, handling conditions described above,

and excludes in the case of a defect which is not related to manufacturing of the cell.

11. Others

12.1 Storage for a long time

If the cell is kept for a long time(3months or more), It is strongly recommended

that the cell is preserved at dry and low-temperature.

12.2 Other

Any matters that specifications does not have, should be conferred with

between the both parties.

6

Samsung SDI Battery Business Division. SAMSUNG SDI Confidential Proprietary.

Spec. No. ICR18650-22FM Version No. 2.0

12. Packaging

See Fig.2,

Package Drawing

Max. 18.4

Max. 65.0

Unit : mm

Fig. 1 Outline Dimensions of ICR18650-22FM

7

Samsung SDI Battery Business Division. SAMSUNG SDI Confidential Proprietary.

Spec. No.

ICR18650-22FM Version No. 2.0

Fig 2. Package Drawing

8

Samsung SDI Battery Business Division. SAMSUNG SDI Confidential Proprietary.

Spec. No.

ICR18650-22FM Version No. 2.0

Proper Use and Handling of Lithium Ion Cells

See before using lithium-ion cell

Supplied by

Samsung SDIEM

1. General

This document has been prepared to describe the appropriate cautions and

prohibitions, which the customer should take or employ when the customer uses

and handles the lithium ion cell to be manufactured and supplied by Samsung SDIEM in

order to obtain optimum performance and safety.

2. Charging

2.1 Charging current

Charging current should be less than maximum charge current specified in

the product specification.

2.2 Charging voltage

Charging should be done by voltage less than that specified in

the product specification.

2.3 Charging time

Continuous charging under appropriate voltage does not cause any loss of

characteristics. However, the charge timer is recommended to be installed

from a safety consideration, which shuts off further charging at time specified

in the product specification.

2.4 Charging temperature

The cell should be charged within a range of specified temperatures in

the product specification.

2.5 Reverse charging

The cell should be connected, confirming that its poles are correctly aligned.

Inverse charging should be strictly prohibited. If the cell is connected

improperly, it may be damaged.

3. Discharging

3.1 Discharging

3.1.1 The cell should be discharged at less than maximum discharge current

specified in the product specification.

3.2 Discharging temperature

3.2.1 The cell should be discharged within a range of temperatures specified in

the product specification.

3.2.2 Otherwise, it may cause loss of characteristics.

3.3 Over-discharging

9

Samsung SDI Battery Business Division. SAMSUNG SDI Confidential Proprietary.

Spec. No.

ICR18650-22FM Version No. 2.0

3.3.1 The system should be equipped with a device to prevent further discharging

exceeding discharging cut-off voltage specified in the product

specification.(over-discharging)

3.3.2 Over-discharging may cause loss of performance, characteristics, of

battery function.

3.3.3 Over-discharging may occur by self-discharge if the battery is left for

a very long time without any use.

3.3.4 The charger should be equipped with a device to detect cell voltage and to

determine recharging procedures.

4. Storage

4.1 Storage conditions

4.1.1 The cell should be stored within a range of temperatures specified

in the product specification.

4.1.2 Otherwise, it may cause loss of characteristics, leakage and/or rust.

4.2 Long-term storage

4.2.1 The cell should be used within a short period after charging because

long-term storage may cause loss of capacity by self-discharging.

4.2.2. If long-term storage is necessary, the cell should be stored at lower

voltage within a range specified in the product specification, because

storage at higher voltage may cause loss of characteristics.

5. Cycle life

5.1 Cycle life performance

5.1.1 The cell can be charged/discharged repeatedly up to times specified in

the produce specification with a certain level of capacity also specified

in the product specification.

5.1.2 Cycle life may be determined by conditions of charging, discharging,

operating temperature and/or storage.

6. Design of System

6.1 Connection between the cell and the battery

6.1.1 The cell should not be soldered directly with leads. Namely, the cell

should be welded with leads on its terminal and then be soldered with

wire or leads to soldered lead.

6.1.2 Otherwise, it may cause damage of component, such as separator and

insulator, by heat generation.

6.2 Positioning the battery in the System

6.2.1 The battery should be positioned as possible as far from heat sources

and high temperature components.

6.2.2 Otherwise, it may cause loss of characteristics.

10

Samsung SDI Battery Business Division. SAMSUNG SDI Confidential Proprietary.

Spec. No.

ICR18650-22FM Version No. 2.0

6.3 Mechanical shock protection of the battery

6.3.1 The battery should be equipped with appropriate shock absorbers in order to

minimize shock.

6.3.2 Otherwise, it may cause shape distortion, leakage, heat generation

and/or rupture.

6.4 Short-circuit protection of the cell

6.4.1 The cell is equipped with an insulating sleeve to protect short-circuit which

may occur during transportation, battery assembly and /or system

operation.

6.4.2 If the cell sleeve is damaged by some causes such as outside impact,

it may cause short-circuit with some wiring inside the battery.

6.5 Connection between the battery and charger/system

6.5.1 The battery should be designed to be connected only to the specified

charger and system.

6.5.2 A reverse connection of the battery, even in the specified system,

should be avoided by employing special battery design such as

a special terminals.

7. Battery Pack Assembly

7.1 Prohibition of usage of damaged cell

7.1.1 The cell should be inspected visually before battery assembly.

7.1.2 The cell should not be used if sleeve-damage, can-distortion and/or

electrolyte-smell is detected.

7.2 Transportation

7.2.1 If the cell is necessary to transport to order place, such as the

battery manufacturer, careful precautions should be taken to avoid

damage of cell.

8. Others

8.1 Disassembly

8.1.1 The cell should not be dismantled from the battery pack.

8.1.2 Internal short-circuit caused by disassembly may lead to heat generation

and/or venting.

8.1.3 When the electrolyte is coming in contact with the skin or eyes,

wash immediately with fresh water and seek medical advice.

8.2 Short-circuiting

8.2.1 Short-circuit results in very high current which leads to heat generation.

8.2.2 An appropriate circuitry should be employed to protect accidental

short-circuiting.

Samsung SDI Battery Business Division.

11 SAMSUNG SDI Confidential Proprietary.

Spec. No.

ICR18650-22FM Version No. 2.0

8.3 Incineration

8.3.1 Incinerating and disposing of the cell in fire are strictly prohibited,

because it may cause rupture.

8.4 Immersion

8.4.1 Soaking the cell in water is strictly prohibited, because it may cause

melt of components to damaged to functions.

8.5 Mixing use

8.5.1 Different types of cell, or same types but different manufacturer's cell

may lead to cell rupture or damage to system due to the different

characteristics of cell.

8.6 Battery disposal

8.6.1 Although the cell contains no environmentally hazardous component,

such as lead or cadmium. the battery should be disposed according to

the local regulations when it is disposed.

8.6.2 The cell should be disposed with a discharged state to avoid heat generation

by an inadvertent short-circuit.

8.7 Caution - The Battery used in this device may present a risk of fire or chemical burn if

mistreated. Do not disassemble, heat above 100℃ or incinerate. Replace

battery with Samsung SDI battery only. Use of another battery may present a risk

of fire or explosion. Dispose of used battery promptly. Keep away from children.

Do not disassemble and do not dispose of in fire.

8.8 Attached

System Pack Quality Guideline

8-8-1 The battery pack’s consumption current.

- Sleep Mode: Under 250uA.

- Shut Down Mode: Under 10uA (under 2.5V).

8-8-2 SOC 0%

- Any bank voltage in SOC 0% of Pack should be higher than 3.0V.

(Discharging Cut-off Voltage)

8-8-3 Operating Charging Voltage of a cell.

- Normal operating voltage of cell is 4.20V.

- Max operating voltage of cell is 4.25V.

8-8-4 No continuous charge

- Charge cut-off condition : Cut-off Current is higher than 1/20C

(Charging method: CC-CV)

- Initial recharging condition : Remaining Capacity is lower than 90% or Voltage

Samsung SDI Battery Business Division.

12 SAMSUNG SDI Confidential Proprietary.

Spec. No.

ICR18650-22FM Version No. 2.0

is lower than 4.10V

8-8-5 Pre-charging function

- Pre-charge function should be implemented to prevent abnormal high rate

charging after deep discharge.

- Pre-charging condition :

Operation: less than 3.0V

Charging current : Under 150mA/Cell.(Continuous)

Pre-charge stop (Normal Charge Start) : All cells reach 3.0V

8-8-6 Cell voltage monitoring system.

- The system (Charger or Pack) should equip a device to monitor each cell

voltage and to stop charging if a cell imbalance happened.

8-8-7 The battery pack should have warning system for over temperature, over voltage,

over current, and unexpected events would be harm to system. If battery faces

harsh condition such as over temperature, Battery pack should control FET-off

directly.

8-8-8 Mechanical guides.

- PCBA and Cell stack should have heat insulation material between them. (Such

as plastic barrier which is giving air isolation or non-thermal conductive

material.)

- B+ and B- wire connection should not be crossed each other. Do not make wire

which had the voltage difference more than 4.0V get together.

- The material such as double sided tape and rubber which are used in battery

pack should be verified for its flammability

Handling Precaution and Prohibitions of Lithium Ion & Lithium Ion Polymer

Rechargeable Cells and Batteries

Inaccurate handling of lithium ion and lithium ion polymer rechargeable battery may cause leakage, heat,

smoke, an explosion, or fire.

This could cause deterioration of performance or failure. Please be sure to follow instructions carefully.

1.1 Storage

Store the battery at low temperature (below 20℃ is recommended), low humidity, no dust and no

corrosive gas atmosphere.

13

Samsung SDI Battery Business Division. SAMSUNG SDI Confidential Proprietary.

Spec. No.

ICR18650-22FM Version No. 2.0

1.2 Safety precaution and prohibitions

To assure product safety, describe the following precautions in the instruction manual of the

application.

[ Danger!]

■ Electrical misusage

Use dedicated charger.

Use or charge the battery only in the dedicated application.

Don't charge the battery by an electric outlet directly or a cigarette lighter charger.

Don't charge the battery reversely.

■ Environmental misusage

Don't leave the battery near the fire or a heated source.

Don't throw the battery into the fire.

Don't leave, charge or use the battery in a car or similar place where inside of temperature may be

over 60℃.

Don't immerse, throw, wet the battery in water / seawater.

■ others

Don't fold the battery cased with laminated film such as pouch and Polymer.

Don't store the battery in a pocket or a bag together with metallic objects such as keys, necklaces,

hairpins, coins, or screws.

Don't short circuit (+) and (-) terminals with metallic object intentionally.

Don't pierce the battery with a sharp object such as a needle, screw drivers.

Don't heat partial area of the battery with heated objects such as soldering iron.

Don't hit with heavy objects such as a hammer, weight.

Don't step on the battery and throw or drop the battery on the hard floor to avoid mechanical hock.

Don't disassemble the battery or modify the battery design including electric circuit.

Don't solder on the battery directly.

Don't use seriously scared or deformed battery.

Don't put the battery into a microwave oven, dryer ,or high-pressure container.

Don't use or assemble the battery with other makers' batteries, different types and/or models of

batteries such as dry batteries, nickel-metal hydride batteries, or nickel-cadmium batteries.

Don't use or assemble old and new batteries together.

[ Warning! ]

Stop charging the battery if charging isn't completed within the specified time.

Stop using the battery if the battery becomes abnormally hot, order, discoloration, deformation, or

14

Samsung SDI Battery Business Division. SAMSUNG SDI Confidential Proprietary.

Spec. No.

ICR18650-22FM Version No. 2.0

abnormal conditions is detected during use, charge, or storage.

Keep away from fire immediately when leakage or foul odors are detected. If liquid leaks onto your

skin or cloths, wash well with fresh water immediately.

If liquid leaking from the battery gets into your eyes, don't rub your eyes and wash them with clean

water and go to see a doctor immediately.

If the terminals of the battery become dirty, wipe with a dry cloth before using the battery.

The battery can be used within the following temperature ranges. Don't exceed these ranges.

Charge temperature ranges : 0℃ ~ 45℃

Discharge Temperature ranges : -20℃ ~ 60℃

Store the battery at temperature below 60℃

Cover terminals with proper insulating tape before disposal.

[ Caution! ]

■ Electrical misusage

Battery must be charge with constant current-constant voltage (CC/CV).

Charge current must be controlled by specified value in Cell specification.

Cut-off Voltage of charging must be 4.2V.

Charger must stop charging battery by detecting either charging time or current specified in Cell’s

specification.

Discharge current must be controlled by specified value in Cell’s specification.

Cut-off Voltage of discharging must be over 2.5V.

■ others

Keep the battery away from babies and children to avoid any accidents such as swallow.

If younger children use the battery, their guardians should explain the proper handling method and

precaution before using.

Before using the battery, be sure to read the user's manual and precaution of it's handling.

Before using charger, be sure to read the user's manual of the charger.

Before installing and removing the battery from application, be sure to read user's manual of the

application.

Replace the battery when using time of battery becomes much shorter than usual.

Cover terminals with insulating tape before proper disposal.

If the battery is needed to be stored for an long period, battery should be removed from the

application and stored in a place where humidity and temperature are low.

While the battery is charged, used and stored, keep it away from object materials with static electric

chargers.

15

Samsung SDI Battery Business Division. SAMSUNG SDI Confidential Proprietary.

Spec. No.

ICR18650-22FM Version No. 2.0

Safety Handling Procedure for the Transporter

■ Quarantine : Packages that are crushed, punctured or torn open to reveal contents should not be

transported. Such packages should be isolated until the shipper has been consulted,

provided instructions and, if appropriate, arranged to have the product inspected and

repacked.

■ Spilled Product : In the event that damage to packaging results in the release of cells or batteries,

the spilled products should be promptly collected and segregated and the shipper

should be contacted for instructions.

Design of positioning the battery pack in application and charger

To prevent the deterioration of the battery performance caused by heat, battery shall be positioned

away from the area where heat is generated in the application and the charger.

Design of the Battery Pack

Be sure adopting proper safe device such as PTC specified type or model in Cell Specification.

If you intend to adopt different safety device which is not specified in Cell Specification, please

contact Samsung SDI to investigate any potential safety problem.

just in case one protective device is fault.

Please contact following offices when you need any help including safety concerns.

Be sure designing 2nd protective devices such as PTC & PCM at the same time to protect Cell

Samsung SDI Emergency Contact Information

■ Samsung SDI Headquarter.

575 Shin-dong, Youngtong-gu, Suwon, Kyunggi-do

Tel:(+82)31-210-7114 Fax:(+82)31-8006-3689

■ Samsung SDI Chonan factory.

508, Sungsung-Dong, Chonan City, Chungchongnam-Do, Korea

Tel:(+82)41-560-3669 Fax:(+82)41-560-3697

■ Samsung SDI America office.

18600 Broadwick Street Rancho Dominguez CA 90220

Tel:(+1)310-900-5205 Fax:(+1)310-537-1033

■ Samsung SDI Taiwan office.

Rm. 3010, 30F., 333, Keelung Rd. Sec. 1, Taipei, Taiwan

Tel:(+886)2-2728-8469 Fax:(+886)2-2728-8480

16

Samsung SDI Battery Business Division.

2023年12月2日发(作者:谭红豆)

SAMSUNG SDI Confidential Proprietary.

Spec. No.

ICR18650-22FM Version No. 2.0

SPECIFICATION OF PRODUCT

for Lithium-ion Rechargeable Cell

Model : ICR18650-22FM

Aug, 2008

Samsung SDI Co., Ltd.

Battery Business Division

SAMSUNG SDI Confidential Proprietary.

Spec. No.

ICR18650-22FM Version No. 2.0

History of Revisions

Date

()

08.07.01

08.08.11

Rev. No

Ver. 1.0

Ver. 2.0

Initial

Rate charge/discharge SPEC addition

Description

Approved by

QA Development

Sujin han JeongSoon Shin

Sujin han DockYoung Youn

Proposed

by

1

Samsung SDI Battery Business Division. SAMSUNG SDI Confidential Proprietary.

Spec. No.

ICR18650-22FM Version No. 2.0

1. Scope

This product specification has been prepared to specify the rechargeable lithium-ion cell

('cell') to be supplied to the customer by Samsung SDI Co., Ltd.

2. Description and Model

2.1 Description Cell (lithium-ion rechargeable cell)

2.2 Model ICR18650-22FM

3. Nominal Specifications

Item

3.1 Nominal Capacity

3.2 Charging Voltage

3.3 Nominal Voltage

3.4 Charging Method

3.5 Charging Current

3.6 Charging Time

3.7 Max. Charge Current

3.8 Max. Discharge Current

3.9 Discharge Cut-off Voltage

3.10 Cell Weight

3.11 Cell Dimension

3.12 Operating Temperature

3.13 Storage Temperature

Specification

2200mAh (0.2C, 2.75V discharge)

4.2V±0.05 V

3.6V

CC-CV

(constant voltage with limited current)

Standard charge: 1100mA

Rapid charge : 2200mA

Standard charge : 3hours

Rapid charge : 2.5hours

2200mA

4400mA

2.75V

44.5g max

Diameter(max.) : Φ18.4 mm

Height : 65mm max

Charge : 0 to 45℃

Discharge: -20 to 60℃

1 year : -20~25℃(1*)

3 months : -20~45℃(1*)

1 month : -20~60℃(1*)

Note (1): If the cell is kept as ex-factory status(50% of charge),

the capacity recovery rate is more than 80%.

2

Samsung SDI Battery Business Division. SAMSUNG SDI Confidential Proprietary.

Spec. No.

ICR18650-22FM Version No. 2.0

4. Outline Dimensions

See the attachment(Fig. 1)

5. Appearance

There shall be no such defects as scratch, rust, discoloration, leakage which

may adversely affect commercial value of the cell.

6. Standard Test Conditions

6.1 Environmental Conditions

Unless otherwise specified, all tests stated in this specification are

conducted at temperature 25±5℃ and humidity 65±20%.

6.2 Measuring Equipment

(1) Ammeter and Voltmeter

The ammeter and voltmeter should have an accuracy of the grade 0.5 or higher.

(2) Slide caliper

The slide caliper should have 0.05 mm scale.

(3) Impedance meter

The impedance meter with AC 1kHz should be used.

7. Characteristics

7.1 Standard Charge

This "Standard Charge" means charging the cell with charge current

1100mA and constant voltage 4.2V at 25℃ for 3hours.

7.2 Standard Discharge Capacity

The standard discharge capacity is the initial discharge capacity of the cell, which is

measured with discharge current of 440mA with 2.75V cut-off at 25℃ within 1 hour

after the Standard charge.

Standard Discharge Capacity ≥ 2150mAh

7.3 Initial internal impedance

Initial internal impedance measured at AC 1kHz after Standard charge.

Initial internal impedance ≤ 100mΩ

7.4 Temperature Dependence of Discharge Capacity

Discharge capacity comparison at each temperature, measured with discharge

constant current 1100mA and 2.75V cut-off with follow temperature after the standard

charging at 25℃.

Charge Temperature

25℃

Relative Capacity

-10℃

50%

3

Discharge temperature

0℃

70%

25℃

100%

45℃

100%

Samsung SDI Battery Business Division. SAMSUNG SDI Confidential Proprietary.

Spec. No.

ICR18650-22FM Version No. 2.0

Note: If charge temperature and discharge temperature is not the same,

the interval for temperature change is 3 hours.

Percentage as an index of the Standard discharge capacity(=2150mAh) is 100%.

7.5 Temperature Dependence of Charge Capacity

Capacity comparison at each temperature, measured with discharge

constant current 1000mA and 2.75V cut-off at 25℃ after the Standard charge is

as follow temperature.

Relative Capacity

Charge temperature

0℃

80%

25℃

100%

45℃

100%

Discharge temperature

25℃

Note: If charge temperature and discharge temperature is not the same,

the interval for temperature change is 3 hours.

Percentage as an index of the Standard discharge capacity(=2150mAh) is 100%.

7.6 Charge Rate Capabilities

Discharge capacity is measured with constant current 440mA and 2.75V cut-off

after the cell is charged with 4.2V as follows.

Current

Cut-off

Relative

Capacity

Note: Percentage as an index of the capacity at 25℃(=2150mAh) is 100%.

7.7 Discharge Rate Capabilities

Discharge capacity is measured with the various currents in under table and 2.75V

cut-off after the standard charge.

Discharge Condition

0.2C 0.5C 1.0C 2.0C

Current

(440mA) (1100mA) (2200mA) (4400mA)

Relative

100% 95% 90% 80%

Capacity

Note: Percentage as an index of the capacity at 25℃(=2150mAh) is 100%.

4

0.2C

(440mA)

7h or 0.05C

100%

Charge Condition

0.5C

(1100mA)

3h or 0.05C

95%

1.0C

(2200mA)

2.5h or 0.05C

90%

Samsung SDI Battery Business Division. SAMSUNG SDI Confidential Proprietary.

Spec. No. ICR18650-22FM Version No. 2.0

7.8 Cycle Life

Each cycle is an interval between the charge (charge current 1760mA) and the

discharge (discharge current 2200mA) with 2.75V cut-off. Capacity

after 299cycles and plus 1 day, measured under the same condition in 7.2

Capacity ≥ 1500mAh

7.9 Storage Characteristics

Capacity after storage for 30days at 25℃ after the Standard charged,

measured with discharge current 1100mA with 2.75V cut-off at 25℃.

Capacity retention(after the storage) ≥ 1720mAh

7.10 Status of the cell as of ex-factory

The cell should be shipped in 50% charged state.

8. Mechanical Characteristics

8.1 Drop Test

Test method: Cell(as of shipment or full charged) drop onto the oak-board

(thickness:≥30mm) from 4feet height at a random direction 6 times.

Criteria: No leakage

8.2 Vibration Test

Test method: Cell(as of shipment) is vibrated along 2 mutually

perpendicular axes with total excursion of 1.6mm and with

frequency cycling between 10Hz and 55Hz by 1Hz/min.

Criteria: No leakage

9. Safety

10.1 Overcharge Test

Test method: To charge the standard charged cell with 12V and 2200mA at 25℃

for 2.5 hours.

Criteria: No fire, and no explosion.

10.2 External Short-circuit Test

Test method: To short-circuit the standard charged cell by connecting positive and

negative terminal by less than 50mΩwire for 3 hours.

Criteria: No fire, and no explosion.

10.3 Reverse Charge Test

Test method: To charge reversely the standard charged cell with charge current

2200mA for 2.5 hours.

Criteria: No fire, and no explosion.

5

Samsung SDI Battery Business Division. SAMSUNG SDI Confidential Proprietary.

Spec. No. ICR18650-22FM Version No. 2.0

10.4 Heating Test

Test method: To heat the standard charged cell at heating rate of 5℃ per minute up to

130℃ and keep the cell in oven for 60 minutes.

Criteria: No fire, and no explosion.

10. Warranty

Samsung SDI will be responsible for replacing the cell against defects or poor workmanship

for 15month from the date of shipping. Any other problems caused by malfunction of the

equipment or unsuitable use of the cell are not under this warranty.

The warranty set forth in proper use, handling conditions described above,

and excludes in the case of a defect which is not related to manufacturing of the cell.

11. Others

12.1 Storage for a long time

If the cell is kept for a long time(3months or more), It is strongly recommended

that the cell is preserved at dry and low-temperature.

12.2 Other

Any matters that specifications does not have, should be conferred with

between the both parties.

6

Samsung SDI Battery Business Division. SAMSUNG SDI Confidential Proprietary.

Spec. No. ICR18650-22FM Version No. 2.0

12. Packaging

See Fig.2,

Package Drawing

Max. 18.4

Max. 65.0

Unit : mm

Fig. 1 Outline Dimensions of ICR18650-22FM

7

Samsung SDI Battery Business Division. SAMSUNG SDI Confidential Proprietary.

Spec. No.

ICR18650-22FM Version No. 2.0

Fig 2. Package Drawing

8

Samsung SDI Battery Business Division. SAMSUNG SDI Confidential Proprietary.

Spec. No.

ICR18650-22FM Version No. 2.0

Proper Use and Handling of Lithium Ion Cells

See before using lithium-ion cell

Supplied by

Samsung SDIEM

1. General

This document has been prepared to describe the appropriate cautions and

prohibitions, which the customer should take or employ when the customer uses

and handles the lithium ion cell to be manufactured and supplied by Samsung SDIEM in

order to obtain optimum performance and safety.

2. Charging

2.1 Charging current

Charging current should be less than maximum charge current specified in

the product specification.

2.2 Charging voltage

Charging should be done by voltage less than that specified in

the product specification.

2.3 Charging time

Continuous charging under appropriate voltage does not cause any loss of

characteristics. However, the charge timer is recommended to be installed

from a safety consideration, which shuts off further charging at time specified

in the product specification.

2.4 Charging temperature

The cell should be charged within a range of specified temperatures in

the product specification.

2.5 Reverse charging

The cell should be connected, confirming that its poles are correctly aligned.

Inverse charging should be strictly prohibited. If the cell is connected

improperly, it may be damaged.

3. Discharging

3.1 Discharging

3.1.1 The cell should be discharged at less than maximum discharge current

specified in the product specification.

3.2 Discharging temperature

3.2.1 The cell should be discharged within a range of temperatures specified in

the product specification.

3.2.2 Otherwise, it may cause loss of characteristics.

3.3 Over-discharging

9

Samsung SDI Battery Business Division. SAMSUNG SDI Confidential Proprietary.

Spec. No.

ICR18650-22FM Version No. 2.0

3.3.1 The system should be equipped with a device to prevent further discharging

exceeding discharging cut-off voltage specified in the product

specification.(over-discharging)

3.3.2 Over-discharging may cause loss of performance, characteristics, of

battery function.

3.3.3 Over-discharging may occur by self-discharge if the battery is left for

a very long time without any use.

3.3.4 The charger should be equipped with a device to detect cell voltage and to

determine recharging procedures.

4. Storage

4.1 Storage conditions

4.1.1 The cell should be stored within a range of temperatures specified

in the product specification.

4.1.2 Otherwise, it may cause loss of characteristics, leakage and/or rust.

4.2 Long-term storage

4.2.1 The cell should be used within a short period after charging because

long-term storage may cause loss of capacity by self-discharging.

4.2.2. If long-term storage is necessary, the cell should be stored at lower

voltage within a range specified in the product specification, because

storage at higher voltage may cause loss of characteristics.

5. Cycle life

5.1 Cycle life performance

5.1.1 The cell can be charged/discharged repeatedly up to times specified in

the produce specification with a certain level of capacity also specified

in the product specification.

5.1.2 Cycle life may be determined by conditions of charging, discharging,

operating temperature and/or storage.

6. Design of System

6.1 Connection between the cell and the battery

6.1.1 The cell should not be soldered directly with leads. Namely, the cell

should be welded with leads on its terminal and then be soldered with

wire or leads to soldered lead.

6.1.2 Otherwise, it may cause damage of component, such as separator and

insulator, by heat generation.

6.2 Positioning the battery in the System

6.2.1 The battery should be positioned as possible as far from heat sources

and high temperature components.

6.2.2 Otherwise, it may cause loss of characteristics.

10

Samsung SDI Battery Business Division. SAMSUNG SDI Confidential Proprietary.

Spec. No.

ICR18650-22FM Version No. 2.0

6.3 Mechanical shock protection of the battery

6.3.1 The battery should be equipped with appropriate shock absorbers in order to

minimize shock.

6.3.2 Otherwise, it may cause shape distortion, leakage, heat generation

and/or rupture.

6.4 Short-circuit protection of the cell

6.4.1 The cell is equipped with an insulating sleeve to protect short-circuit which

may occur during transportation, battery assembly and /or system

operation.

6.4.2 If the cell sleeve is damaged by some causes such as outside impact,

it may cause short-circuit with some wiring inside the battery.

6.5 Connection between the battery and charger/system

6.5.1 The battery should be designed to be connected only to the specified

charger and system.

6.5.2 A reverse connection of the battery, even in the specified system,

should be avoided by employing special battery design such as

a special terminals.

7. Battery Pack Assembly

7.1 Prohibition of usage of damaged cell

7.1.1 The cell should be inspected visually before battery assembly.

7.1.2 The cell should not be used if sleeve-damage, can-distortion and/or

electrolyte-smell is detected.

7.2 Transportation

7.2.1 If the cell is necessary to transport to order place, such as the

battery manufacturer, careful precautions should be taken to avoid

damage of cell.

8. Others

8.1 Disassembly

8.1.1 The cell should not be dismantled from the battery pack.

8.1.2 Internal short-circuit caused by disassembly may lead to heat generation

and/or venting.

8.1.3 When the electrolyte is coming in contact with the skin or eyes,

wash immediately with fresh water and seek medical advice.

8.2 Short-circuiting

8.2.1 Short-circuit results in very high current which leads to heat generation.

8.2.2 An appropriate circuitry should be employed to protect accidental

short-circuiting.

Samsung SDI Battery Business Division.

11 SAMSUNG SDI Confidential Proprietary.

Spec. No.

ICR18650-22FM Version No. 2.0

8.3 Incineration

8.3.1 Incinerating and disposing of the cell in fire are strictly prohibited,

because it may cause rupture.

8.4 Immersion

8.4.1 Soaking the cell in water is strictly prohibited, because it may cause

melt of components to damaged to functions.

8.5 Mixing use

8.5.1 Different types of cell, or same types but different manufacturer's cell

may lead to cell rupture or damage to system due to the different

characteristics of cell.

8.6 Battery disposal

8.6.1 Although the cell contains no environmentally hazardous component,

such as lead or cadmium. the battery should be disposed according to

the local regulations when it is disposed.

8.6.2 The cell should be disposed with a discharged state to avoid heat generation

by an inadvertent short-circuit.

8.7 Caution - The Battery used in this device may present a risk of fire or chemical burn if

mistreated. Do not disassemble, heat above 100℃ or incinerate. Replace

battery with Samsung SDI battery only. Use of another battery may present a risk

of fire or explosion. Dispose of used battery promptly. Keep away from children.

Do not disassemble and do not dispose of in fire.

8.8 Attached

System Pack Quality Guideline

8-8-1 The battery pack’s consumption current.

- Sleep Mode: Under 250uA.

- Shut Down Mode: Under 10uA (under 2.5V).

8-8-2 SOC 0%

- Any bank voltage in SOC 0% of Pack should be higher than 3.0V.

(Discharging Cut-off Voltage)

8-8-3 Operating Charging Voltage of a cell.

- Normal operating voltage of cell is 4.20V.

- Max operating voltage of cell is 4.25V.

8-8-4 No continuous charge

- Charge cut-off condition : Cut-off Current is higher than 1/20C

(Charging method: CC-CV)

- Initial recharging condition : Remaining Capacity is lower than 90% or Voltage

Samsung SDI Battery Business Division.

12 SAMSUNG SDI Confidential Proprietary.

Spec. No.

ICR18650-22FM Version No. 2.0

is lower than 4.10V

8-8-5 Pre-charging function

- Pre-charge function should be implemented to prevent abnormal high rate

charging after deep discharge.

- Pre-charging condition :

Operation: less than 3.0V

Charging current : Under 150mA/Cell.(Continuous)

Pre-charge stop (Normal Charge Start) : All cells reach 3.0V

8-8-6 Cell voltage monitoring system.

- The system (Charger or Pack) should equip a device to monitor each cell

voltage and to stop charging if a cell imbalance happened.

8-8-7 The battery pack should have warning system for over temperature, over voltage,

over current, and unexpected events would be harm to system. If battery faces

harsh condition such as over temperature, Battery pack should control FET-off

directly.

8-8-8 Mechanical guides.

- PCBA and Cell stack should have heat insulation material between them. (Such

as plastic barrier which is giving air isolation or non-thermal conductive

material.)

- B+ and B- wire connection should not be crossed each other. Do not make wire

which had the voltage difference more than 4.0V get together.

- The material such as double sided tape and rubber which are used in battery

pack should be verified for its flammability

Handling Precaution and Prohibitions of Lithium Ion & Lithium Ion Polymer

Rechargeable Cells and Batteries

Inaccurate handling of lithium ion and lithium ion polymer rechargeable battery may cause leakage, heat,

smoke, an explosion, or fire.

This could cause deterioration of performance or failure. Please be sure to follow instructions carefully.

1.1 Storage

Store the battery at low temperature (below 20℃ is recommended), low humidity, no dust and no

corrosive gas atmosphere.

13

Samsung SDI Battery Business Division. SAMSUNG SDI Confidential Proprietary.

Spec. No.

ICR18650-22FM Version No. 2.0

1.2 Safety precaution and prohibitions

To assure product safety, describe the following precautions in the instruction manual of the

application.

[ Danger!]

■ Electrical misusage

Use dedicated charger.

Use or charge the battery only in the dedicated application.

Don't charge the battery by an electric outlet directly or a cigarette lighter charger.

Don't charge the battery reversely.

■ Environmental misusage

Don't leave the battery near the fire or a heated source.

Don't throw the battery into the fire.

Don't leave, charge or use the battery in a car or similar place where inside of temperature may be

over 60℃.

Don't immerse, throw, wet the battery in water / seawater.

■ others

Don't fold the battery cased with laminated film such as pouch and Polymer.

Don't store the battery in a pocket or a bag together with metallic objects such as keys, necklaces,

hairpins, coins, or screws.

Don't short circuit (+) and (-) terminals with metallic object intentionally.

Don't pierce the battery with a sharp object such as a needle, screw drivers.

Don't heat partial area of the battery with heated objects such as soldering iron.

Don't hit with heavy objects such as a hammer, weight.

Don't step on the battery and throw or drop the battery on the hard floor to avoid mechanical hock.

Don't disassemble the battery or modify the battery design including electric circuit.

Don't solder on the battery directly.

Don't use seriously scared or deformed battery.

Don't put the battery into a microwave oven, dryer ,or high-pressure container.

Don't use or assemble the battery with other makers' batteries, different types and/or models of

batteries such as dry batteries, nickel-metal hydride batteries, or nickel-cadmium batteries.

Don't use or assemble old and new batteries together.

[ Warning! ]

Stop charging the battery if charging isn't completed within the specified time.

Stop using the battery if the battery becomes abnormally hot, order, discoloration, deformation, or

14

Samsung SDI Battery Business Division. SAMSUNG SDI Confidential Proprietary.

Spec. No.

ICR18650-22FM Version No. 2.0

abnormal conditions is detected during use, charge, or storage.

Keep away from fire immediately when leakage or foul odors are detected. If liquid leaks onto your

skin or cloths, wash well with fresh water immediately.

If liquid leaking from the battery gets into your eyes, don't rub your eyes and wash them with clean

water and go to see a doctor immediately.

If the terminals of the battery become dirty, wipe with a dry cloth before using the battery.

The battery can be used within the following temperature ranges. Don't exceed these ranges.

Charge temperature ranges : 0℃ ~ 45℃

Discharge Temperature ranges : -20℃ ~ 60℃

Store the battery at temperature below 60℃

Cover terminals with proper insulating tape before disposal.

[ Caution! ]

■ Electrical misusage

Battery must be charge with constant current-constant voltage (CC/CV).

Charge current must be controlled by specified value in Cell specification.

Cut-off Voltage of charging must be 4.2V.

Charger must stop charging battery by detecting either charging time or current specified in Cell’s

specification.

Discharge current must be controlled by specified value in Cell’s specification.

Cut-off Voltage of discharging must be over 2.5V.

■ others

Keep the battery away from babies and children to avoid any accidents such as swallow.

If younger children use the battery, their guardians should explain the proper handling method and

precaution before using.

Before using the battery, be sure to read the user's manual and precaution of it's handling.

Before using charger, be sure to read the user's manual of the charger.

Before installing and removing the battery from application, be sure to read user's manual of the

application.

Replace the battery when using time of battery becomes much shorter than usual.

Cover terminals with insulating tape before proper disposal.

If the battery is needed to be stored for an long period, battery should be removed from the

application and stored in a place where humidity and temperature are low.

While the battery is charged, used and stored, keep it away from object materials with static electric

chargers.

15

Samsung SDI Battery Business Division. SAMSUNG SDI Confidential Proprietary.

Spec. No.

ICR18650-22FM Version No. 2.0

Safety Handling Procedure for the Transporter

■ Quarantine : Packages that are crushed, punctured or torn open to reveal contents should not be

transported. Such packages should be isolated until the shipper has been consulted,

provided instructions and, if appropriate, arranged to have the product inspected and

repacked.

■ Spilled Product : In the event that damage to packaging results in the release of cells or batteries,

the spilled products should be promptly collected and segregated and the shipper

should be contacted for instructions.

Design of positioning the battery pack in application and charger

To prevent the deterioration of the battery performance caused by heat, battery shall be positioned

away from the area where heat is generated in the application and the charger.

Design of the Battery Pack

Be sure adopting proper safe device such as PTC specified type or model in Cell Specification.

If you intend to adopt different safety device which is not specified in Cell Specification, please

contact Samsung SDI to investigate any potential safety problem.

just in case one protective device is fault.

Please contact following offices when you need any help including safety concerns.

Be sure designing 2nd protective devices such as PTC & PCM at the same time to protect Cell

Samsung SDI Emergency Contact Information

■ Samsung SDI Headquarter.

575 Shin-dong, Youngtong-gu, Suwon, Kyunggi-do

Tel:(+82)31-210-7114 Fax:(+82)31-8006-3689

■ Samsung SDI Chonan factory.

508, Sungsung-Dong, Chonan City, Chungchongnam-Do, Korea

Tel:(+82)41-560-3669 Fax:(+82)41-560-3697

■ Samsung SDI America office.

18600 Broadwick Street Rancho Dominguez CA 90220

Tel:(+1)310-900-5205 Fax:(+1)310-537-1033

■ Samsung SDI Taiwan office.

Rm. 3010, 30F., 333, Keelung Rd. Sec. 1, Taipei, Taiwan

Tel:(+886)2-2728-8469 Fax:(+886)2-2728-8480