2024年3月13日发(作者:遇飞语)
全球主要“GC-MS”生产厂商及其产品比较一览
Supplier System Type mass analyser
Mass
(m/z)-range
Ionisation
techniques
Data acquisition and
processing software
Agilent-MSD
Chemstation
Compatibility
in control of Remarks
GC systems
Agiilent-6890 spectral libraries available
curved prefilter-technology; probes and
digital CI-control, 10.000 amu/sec to 50
scans per second, SIM and Fullscan
simultaneous
External Ionisation, MS-MS, Probes, NCI
and digital CI-control
Agilent
Technologies
Agilent 5973-N single-quadrupole 800 EI, PCI, NCI
THERMO
FINNIGAN
EI, PCI, NCI
TraceDSQ single-quadrupole 1-1050 en EI/CI Xcalibur (Windows 2000) TraceGC
combibron
THERMO
FINNIGAN
Polaris-Q ion-trap 10-1000 EI, PCI, NCI Xcalibur (Windows 2000) TraceGC
TraceGC
THERMO
FINNIGAN
(with
Tempus TOF 2-1000
Ultra
EI, PCI, NCI Xcalibur (Windows 2000) Fast Option,
up to 1200
C/min)
Benchtop, >100 scans/sec, >10^5 dynamic
range.
JEOL
(EUROPE)
B.V.
JEOL
(EUROPE)
B.V.
Mstation JMS-700
GCMate II
magnetic sector,
double focusing
2500
EI, PCI, NCI,
FAB
EI, PCI, NCI,
5000 Resolution, Benchtop Model, Full
Jeol software (Windows) Agilent-6890 Automatic Probe Analysis, MS/MS Linked
scan
60000 resolution. Dedicated dioxine
version avialable.
magnetic sector,
double focusing
25000 FAB, FD, FI, Jeol software
DCI,
Agilent-6890
MassLynx 4.0 (Windows
XP, NT or Windows 2000),
Micromass GCT time-of-flight 1500
EI, PCI, NCI,
FI
MassLynx is CFR 21 part
11 complaint.; Various
integrated couplings
to, e.g., AMDIS,.NIST,
ACD, nugenesis
Agilent-6890,
Micromass Quattro-Micro triple-quadrupole 1200 EI, PCI, NCI,
various
injectors,
e.g., CTC Pal
EI, CI, and
all
Micromass AutoSpec
magnetic sector,
double focusing
vanaf 3000
other
ionisation
technologies
available:
FI, FAB, ESI,
APCI, MALDI
PCI/NCI
PerkinElmer
Benelux
Clarus 500 GC/MS single-quadrupole 1200 EI, CI+, CI- Clarus (Windows NT)
PerkinElmer
option, SIFI Mode with
Agilent-6890,
various
injectors,
e.g., CTC Pal
Resolution 60000 (20% valley)
Bechtop MS-MS, Solids-probe option
Agilent-6890,
various
injectors,
e.g., CTC Pal
Resolution 7000 at 3.5 GHz TDC; better than
1 mDa at m/z < 200, better than 5 ppm at
m/z > 200; Solids-probe option
Simultaneous Full Scan and SIM, LVI and MS
under vacuum) Touchscreen monitoring
Clarus 500 GC Vent (column backflush or column change
700
Shimadzu QP5000 and QP5050A single-quadrupole
(QP5000);
900
(QP5050A)
EI, PCI, NCI
combination
CI and SEI
GCMSsolutions (windows Shimadzu
2000, NT) GC-17A
Direct Insertion probe and Pyrolysis unit
available, spectral libraries, Suitable
for fast GC-MS
Sensitivity in sub femtogram range (10-15
gr); Fast GC (10000amu/sec); new ion
optics, High End GCMS
EI, PCI, NCI GCMSsolutions with MS
Shimadzu QP2010 single-quadrupole 1.5 - 1024 combination
CI and SEI
Navigator
2000)
(Windows
Shimadzu
GC2010 (+FID)
Thermo
Finnigan
MAT95
GC-MS
magnetic sector, 3500 Da at DIP en DCI probes as Option. Ion-Trap
XP EI, PCI, NCI, Trace 2000 and
double focusing maximum Xcalibur (Windows 2000) option for MS-MS available. Dedicated
FAB, FD/FI. Agilent 6890
(BE) acceleration dioxine analysis system available.
magnetic sector, 5000 Da at DIP en DCI probes as Option. Ion-Trap
XL EI, PCI, NCI, Trace 2000 and
double focusing maximum Xcalibur (Windows 2000) option for MS-MS available. PATRIC
FAB, FD/FI. Agilent 6890
(EB) acceleration detector as option
ion-trap 650 EI, CI,
Star vs. 5 (Windows Varian
95,98,NT, 2000) CP-3900
MS-MS, SIS, liquid CI
Thermo
Finnigan
Varian
Chrompack
Varian
Chrompack
Varian
Chrompack
Varian
Chrompack
MAT900
GC-MS
Saturn 2100
Saturn 2200
1200
Single-quadrupole
1200
Triple-quadrupole
ion-trap 650 EI, CI
Star vs. 5 (Windows Varian
95,98,NT, 2000) CP-3800
MS-MS, SIS, liquid CI
Probe, vacuum interlock, possibility to
upgrade to LC-MS-MS and GC-MS-MS
MS-MS, probe, vacuum interlock, curved
collision cell, possibility to upgrade to
LC-MS-MS
single-quadrupole 800, (1500) EI, PCI, NCI
Paw software (Windows Varian
2000) CP-3800
triple-quadrupole 800, (1500) EI, PCI, NCI
Paw software (Windows Varian
2000) CP-3800
2024年3月13日发(作者:遇飞语)
全球主要“GC-MS”生产厂商及其产品比较一览
Supplier System Type mass analyser
Mass
(m/z)-range
Ionisation
techniques
Data acquisition and
processing software
Agilent-MSD
Chemstation
Compatibility
in control of Remarks
GC systems
Agiilent-6890 spectral libraries available
curved prefilter-technology; probes and
digital CI-control, 10.000 amu/sec to 50
scans per second, SIM and Fullscan
simultaneous
External Ionisation, MS-MS, Probes, NCI
and digital CI-control
Agilent
Technologies
Agilent 5973-N single-quadrupole 800 EI, PCI, NCI
THERMO
FINNIGAN
EI, PCI, NCI
TraceDSQ single-quadrupole 1-1050 en EI/CI Xcalibur (Windows 2000) TraceGC
combibron
THERMO
FINNIGAN
Polaris-Q ion-trap 10-1000 EI, PCI, NCI Xcalibur (Windows 2000) TraceGC
TraceGC
THERMO
FINNIGAN
(with
Tempus TOF 2-1000
Ultra
EI, PCI, NCI Xcalibur (Windows 2000) Fast Option,
up to 1200
C/min)
Benchtop, >100 scans/sec, >10^5 dynamic
range.
JEOL
(EUROPE)
B.V.
JEOL
(EUROPE)
B.V.
Mstation JMS-700
GCMate II
magnetic sector,
double focusing
2500
EI, PCI, NCI,
FAB
EI, PCI, NCI,
5000 Resolution, Benchtop Model, Full
Jeol software (Windows) Agilent-6890 Automatic Probe Analysis, MS/MS Linked
scan
60000 resolution. Dedicated dioxine
version avialable.
magnetic sector,
double focusing
25000 FAB, FD, FI, Jeol software
DCI,
Agilent-6890
MassLynx 4.0 (Windows
XP, NT or Windows 2000),
Micromass GCT time-of-flight 1500
EI, PCI, NCI,
FI
MassLynx is CFR 21 part
11 complaint.; Various
integrated couplings
to, e.g., AMDIS,.NIST,
ACD, nugenesis
Agilent-6890,
Micromass Quattro-Micro triple-quadrupole 1200 EI, PCI, NCI,
various
injectors,
e.g., CTC Pal
EI, CI, and
all
Micromass AutoSpec
magnetic sector,
double focusing
vanaf 3000
other
ionisation
technologies
available:
FI, FAB, ESI,
APCI, MALDI
PCI/NCI
PerkinElmer
Benelux
Clarus 500 GC/MS single-quadrupole 1200 EI, CI+, CI- Clarus (Windows NT)
PerkinElmer
option, SIFI Mode with
Agilent-6890,
various
injectors,
e.g., CTC Pal
Resolution 60000 (20% valley)
Bechtop MS-MS, Solids-probe option
Agilent-6890,
various
injectors,
e.g., CTC Pal
Resolution 7000 at 3.5 GHz TDC; better than
1 mDa at m/z < 200, better than 5 ppm at
m/z > 200; Solids-probe option
Simultaneous Full Scan and SIM, LVI and MS
under vacuum) Touchscreen monitoring
Clarus 500 GC Vent (column backflush or column change
700
Shimadzu QP5000 and QP5050A single-quadrupole
(QP5000);
900
(QP5050A)
EI, PCI, NCI
combination
CI and SEI
GCMSsolutions (windows Shimadzu
2000, NT) GC-17A
Direct Insertion probe and Pyrolysis unit
available, spectral libraries, Suitable
for fast GC-MS
Sensitivity in sub femtogram range (10-15
gr); Fast GC (10000amu/sec); new ion
optics, High End GCMS
EI, PCI, NCI GCMSsolutions with MS
Shimadzu QP2010 single-quadrupole 1.5 - 1024 combination
CI and SEI
Navigator
2000)
(Windows
Shimadzu
GC2010 (+FID)
Thermo
Finnigan
MAT95
GC-MS
magnetic sector, 3500 Da at DIP en DCI probes as Option. Ion-Trap
XP EI, PCI, NCI, Trace 2000 and
double focusing maximum Xcalibur (Windows 2000) option for MS-MS available. Dedicated
FAB, FD/FI. Agilent 6890
(BE) acceleration dioxine analysis system available.
magnetic sector, 5000 Da at DIP en DCI probes as Option. Ion-Trap
XL EI, PCI, NCI, Trace 2000 and
double focusing maximum Xcalibur (Windows 2000) option for MS-MS available. PATRIC
FAB, FD/FI. Agilent 6890
(EB) acceleration detector as option
ion-trap 650 EI, CI,
Star vs. 5 (Windows Varian
95,98,NT, 2000) CP-3900
MS-MS, SIS, liquid CI
Thermo
Finnigan
Varian
Chrompack
Varian
Chrompack
Varian
Chrompack
Varian
Chrompack
MAT900
GC-MS
Saturn 2100
Saturn 2200
1200
Single-quadrupole
1200
Triple-quadrupole
ion-trap 650 EI, CI
Star vs. 5 (Windows Varian
95,98,NT, 2000) CP-3800
MS-MS, SIS, liquid CI
Probe, vacuum interlock, possibility to
upgrade to LC-MS-MS and GC-MS-MS
MS-MS, probe, vacuum interlock, curved
collision cell, possibility to upgrade to
LC-MS-MS
single-quadrupole 800, (1500) EI, PCI, NCI
Paw software (Windows Varian
2000) CP-3800
triple-quadrupole 800, (1500) EI, PCI, NCI
Paw software (Windows Varian
2000) CP-3800