Technical Data 4406
Effective June 2023
Supersedes November 2021
S505H
5 mm x 20 mm 400 Vdc/500-600 Vac time-delay fuse
Product features
•
400 Vdc/500-600 Vac rating
•
Time-delay, high breaking capacity
•
5 mm x 20 mm physical size
•
Ceramic tube with plated end cap
construction
•
Designed to IEC 60127-2, Standard, Sheet 5
•
Optional axial leads available
•
Fuse accesories guide (holders, clips)
Ordering part number
the “
The ordering code is the part number replacing
.” with a “-”
BK-S505H-V-6-3-R
Packaging prefix
Family name
Option code (V = axial leaded)
Ampere rating
RoHS compliance
Packaging prefix
•
Blank:
lead parts in a 5 inch tin) (Values < 12 A only)
5 cartridge parts in a 5 inch tin, 4 axial
•
BK-:
(axial leaded only)
100 parts packed in a cardboard carton
•
BK1-:
sion only)
1000 parts in a poly bag (cartridge ver-
•
TR2-
only, values < 12 A only)
1500 parts on a reel (axial lead V option
Option code
•
-V :
nickel plated brass end caps)
(Axial leads – copper tinned wire with
Applications
•
Power supplies - adapters
•
Desktops/notebooks
•
TVs / Displays
•
Set top boxes
•
Lighting ballasts
•
Battery chargers
•
Printers
•
Game systems
•
Air conditioners
Agency information
S505H-XXX-R (Cartridge)
•
cURus Recognition file:
E56412, Guide JFHR2,JFHR8, (500 mA - 10 A);
E19180, Guide JDYX2 and JDYX8, (12 A - 20 A)
•
CCC Approval: 500 mA - 10 A, Cert. No.:
2249
•
TUV Approval: 2 A - 10 A, Cert. No.: R50297821
•
PSE Approval: 1 A - 5 A, Cert. No.: JET1641-
31003-1025; 6.3 A - 10 A JET1641-31003-1023
•
KC Approval: SU05011-21001A (1 A - 2.5 A),
SU05011-21002A (3.15 A - 6.3 A), SU05011-
21003A (8 A -10 A), SU05011-21004A (500 mA
- 800 mA)
S505H-V-XXX-R (Axial leads)
•
cURus Recognition file:
E56412, Guide JFHR2,JFHR8, (500 mA - 10 A)
E19180, Guide JDYX2 and JDYX8, (12 A - 20 A)
•
PSE Approval: 1 A - 5 A, Cert.
No.:JET164131003-1026;
No: JET1641-31003-1024
6.3 A - 10 A, Cert.
•
CCC Approval: 500 mA - 10 A, Cert. No.:
2249
•
TUV Approval: 500 mA-10 A, Cert. No.:
R50297821
•
KC Approval: SU05011-21001A (1 A - 2.5 A),
SU05011-21002A (3.15 A - 6.3 A), SU05011-
21003A (8 A -10 A), SU05011-21004A (500 mA
- 800 mA)
Environmental compliance
Pb
HF
HALOGEN
FREE
Technical Data 4406
Effective June 2023
S505H
5 mm x 20 mm 400 Vdc/500-600 Vac time-delay fuse
Electrical characteristics
Amp Rating
1.5 In
minimum
minutes
2.1 In
maximum
minutes
2.75 In
minimum
ms
maximum
seconds
4.0 In
minimum
ms
maximum
seconds
10 In
mimimum
ms
maximum
ms
500 mA - 1 A
1 A - 3.15 A
4 A -6.3 A
8 A -10 A
12 A - 20 A
60
60
60
30
30*
30
30
30
30
30
250
750
750
750
750
80
80
80
80
80
50
95
150
150
150
5
5
5
5
8
5
10
10
10
10
150
150
150
150
150
* 1.5 In rating for cartridge version only
Product specifications
Part number
Current
rating
(A)
Voltage rating
1
(Vac)(Vdc)
Interrupting rating @ rated voltage
(A) @ (A) @ (A) @
250 Vac
2
600 Vac
3
400 Vdc
4
Typical DC
cold resistance
5
(Ω)
Typical
voltage drop
6
(mV)
Typical
melting
7
I
2
t (A
2
s)
Agency approvals
250 Vac
TuvCCCPSE/JETcURus
9
S505H(-V)-500-R
S505H(-V)-800-R
S505H(-V)-1-R
S505H(-V)-1.25-R
S505H(-V)-1.6-R
S505H(-V)-2-R
S505H(-V)-2.5-R
S505H(-V)-3.15-R
S505H(-V)-4-R
S505H(-V)-5-R
S505H(-V)-6.3-R
S505H(-V)-8-R
S505H(-V)-10-R
S505H(-V)-12-R
S505H(-V)-15-R
S505H(-V)-16-R
S505H(-V)-20-R
0.5
0.8
1
1.25
1.6
2
2.5
3.15
4
5
6.3
8
10
12
15
16
20
600
600
600
600
600
600
600
600
600
600
500
500
500
500
500
500
500
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
na
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
na
na
na
na
100
100
100
100
100
100
100
100
100
100
100 @ 500 Vac
100 @ 500 Vac
100 @ 500 Vac
200 @ 500 Vac
200 @ 500 Vac
200 @ 500 Vac
200 @ 500 Vac
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
300
300
300
na
0.507
0.237
0.157
0.108
0.070
0.055
0.040
0.031
0.019
0.015
0.011
0.007
0.006
0.00545
0.004
0.0037
0.00325
295
189
176
150
125
128
126
121
90
89
80
76
72
80
75
68
75
0.188
0.632
1.28
2.22
6.78
11.44
24.23
43.55
38.45
71.30
111.4
228.2
349.5
550
900
1100
1500
x
8
x
8
x
8
x
8
x
8
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
1. Voltage rating: based on the interrupting rating test according to UL.
2. Interrupting rating of 250 Vac/1500 A is tested by all agency approvals, test
condition is 250 Vac, PF: 0.7 - 0.8.
3. Interrupting rating of Vac is tested with, PF:1.0 (500 mA - 5 A @ 600 Vac, 6.3 A - 20 A @ 500
Vac)
4. Interrupting rating of Vdc is tested under capacitor bank for 500 mA to 10A; Vdc interrupting
rating for 12 A– 20 A is tested under power supply with time constant less than 1 ms.
5. Typical cold resistance measured at <10% rated current.
6. Typical voltage drop measured under ambient +20 °C with rated current
7. Typical melting I
2
t: Measured at 10 In DC
8. Axial lead version only.
9. 600/500 Vac, 400 Vdc.
2
/electronics
2024年3月13日发(作者:袁天华)
Technical Data 4406
Effective June 2023
Supersedes November 2021
S505H
5 mm x 20 mm 400 Vdc/500-600 Vac time-delay fuse
Product features
•
400 Vdc/500-600 Vac rating
•
Time-delay, high breaking capacity
•
5 mm x 20 mm physical size
•
Ceramic tube with plated end cap
construction
•
Designed to IEC 60127-2, Standard, Sheet 5
•
Optional axial leads available
•
Fuse accesories guide (holders, clips)
Ordering part number
the “
The ordering code is the part number replacing
.” with a “-”
BK-S505H-V-6-3-R
Packaging prefix
Family name
Option code (V = axial leaded)
Ampere rating
RoHS compliance
Packaging prefix
•
Blank:
lead parts in a 5 inch tin) (Values < 12 A only)
5 cartridge parts in a 5 inch tin, 4 axial
•
BK-:
(axial leaded only)
100 parts packed in a cardboard carton
•
BK1-:
sion only)
1000 parts in a poly bag (cartridge ver-
•
TR2-
only, values < 12 A only)
1500 parts on a reel (axial lead V option
Option code
•
-V :
nickel plated brass end caps)
(Axial leads – copper tinned wire with
Applications
•
Power supplies - adapters
•
Desktops/notebooks
•
TVs / Displays
•
Set top boxes
•
Lighting ballasts
•
Battery chargers
•
Printers
•
Game systems
•
Air conditioners
Agency information
S505H-XXX-R (Cartridge)
•
cURus Recognition file:
E56412, Guide JFHR2,JFHR8, (500 mA - 10 A);
E19180, Guide JDYX2 and JDYX8, (12 A - 20 A)
•
CCC Approval: 500 mA - 10 A, Cert. No.:
2249
•
TUV Approval: 2 A - 10 A, Cert. No.: R50297821
•
PSE Approval: 1 A - 5 A, Cert. No.: JET1641-
31003-1025; 6.3 A - 10 A JET1641-31003-1023
•
KC Approval: SU05011-21001A (1 A - 2.5 A),
SU05011-21002A (3.15 A - 6.3 A), SU05011-
21003A (8 A -10 A), SU05011-21004A (500 mA
- 800 mA)
S505H-V-XXX-R (Axial leads)
•
cURus Recognition file:
E56412, Guide JFHR2,JFHR8, (500 mA - 10 A)
E19180, Guide JDYX2 and JDYX8, (12 A - 20 A)
•
PSE Approval: 1 A - 5 A, Cert.
No.:JET164131003-1026;
No: JET1641-31003-1024
6.3 A - 10 A, Cert.
•
CCC Approval: 500 mA - 10 A, Cert. No.:
2249
•
TUV Approval: 500 mA-10 A, Cert. No.:
R50297821
•
KC Approval: SU05011-21001A (1 A - 2.5 A),
SU05011-21002A (3.15 A - 6.3 A), SU05011-
21003A (8 A -10 A), SU05011-21004A (500 mA
- 800 mA)
Environmental compliance
Pb
HF
HALOGEN
FREE
Technical Data 4406
Effective June 2023
S505H
5 mm x 20 mm 400 Vdc/500-600 Vac time-delay fuse
Electrical characteristics
Amp Rating
1.5 In
minimum
minutes
2.1 In
maximum
minutes
2.75 In
minimum
ms
maximum
seconds
4.0 In
minimum
ms
maximum
seconds
10 In
mimimum
ms
maximum
ms
500 mA - 1 A
1 A - 3.15 A
4 A -6.3 A
8 A -10 A
12 A - 20 A
60
60
60
30
30*
30
30
30
30
30
250
750
750
750
750
80
80
80
80
80
50
95
150
150
150
5
5
5
5
8
5
10
10
10
10
150
150
150
150
150
* 1.5 In rating for cartridge version only
Product specifications
Part number
Current
rating
(A)
Voltage rating
1
(Vac)(Vdc)
Interrupting rating @ rated voltage
(A) @ (A) @ (A) @
250 Vac
2
600 Vac
3
400 Vdc
4
Typical DC
cold resistance
5
(Ω)
Typical
voltage drop
6
(mV)
Typical
melting
7
I
2
t (A
2
s)
Agency approvals
250 Vac
TuvCCCPSE/JETcURus
9
S505H(-V)-500-R
S505H(-V)-800-R
S505H(-V)-1-R
S505H(-V)-1.25-R
S505H(-V)-1.6-R
S505H(-V)-2-R
S505H(-V)-2.5-R
S505H(-V)-3.15-R
S505H(-V)-4-R
S505H(-V)-5-R
S505H(-V)-6.3-R
S505H(-V)-8-R
S505H(-V)-10-R
S505H(-V)-12-R
S505H(-V)-15-R
S505H(-V)-16-R
S505H(-V)-20-R
0.5
0.8
1
1.25
1.6
2
2.5
3.15
4
5
6.3
8
10
12
15
16
20
600
600
600
600
600
600
600
600
600
600
500
500
500
500
500
500
500
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
na
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
na
na
na
na
100
100
100
100
100
100
100
100
100
100
100 @ 500 Vac
100 @ 500 Vac
100 @ 500 Vac
200 @ 500 Vac
200 @ 500 Vac
200 @ 500 Vac
200 @ 500 Vac
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
300
300
300
na
0.507
0.237
0.157
0.108
0.070
0.055
0.040
0.031
0.019
0.015
0.011
0.007
0.006
0.00545
0.004
0.0037
0.00325
295
189
176
150
125
128
126
121
90
89
80
76
72
80
75
68
75
0.188
0.632
1.28
2.22
6.78
11.44
24.23
43.55
38.45
71.30
111.4
228.2
349.5
550
900
1100
1500
x
8
x
8
x
8
x
8
x
8
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
1. Voltage rating: based on the interrupting rating test according to UL.
2. Interrupting rating of 250 Vac/1500 A is tested by all agency approvals, test
condition is 250 Vac, PF: 0.7 - 0.8.
3. Interrupting rating of Vac is tested with, PF:1.0 (500 mA - 5 A @ 600 Vac, 6.3 A - 20 A @ 500
Vac)
4. Interrupting rating of Vdc is tested under capacitor bank for 500 mA to 10A; Vdc interrupting
rating for 12 A– 20 A is tested under power supply with time constant less than 1 ms.
5. Typical cold resistance measured at <10% rated current.
6. Typical voltage drop measured under ambient +20 °C with rated current
7. Typical melting I
2
t: Measured at 10 In DC
8. Axial lead version only.
9. 600/500 Vac, 400 Vdc.
2
/electronics