Technical Data 4406

Effective June 2023

Supersedes November 2021

S505H

5 mm x 20 mm 400 Vdc/500-600 Vac time-delay fuse

Product features

400 Vdc/500-600 Vac rating

Time-delay, high breaking capacity

5 mm x 20 mm physical size

Ceramic tube with plated end cap

construction

Designed to IEC 60127-2, Standard, Sheet 5

Optional axial leads available

Fuse accesories guide (holders, clips)

Ordering part number

the “

The ordering code is the part number replacing

.” with a “-”

BK-S505H-V-6-3-R

Packaging prefix

Family name

Option code (V = axial leaded)

Ampere rating

RoHS compliance

Packaging prefix

Blank:

lead parts in a 5 inch tin) (Values < 12 A only)

5 cartridge parts in a 5 inch tin, 4 axial

BK-:

(axial leaded only)

100 parts packed in a cardboard carton

BK1-:

sion only)

1000 parts in a poly bag (cartridge ver-

TR2-

only, values < 12 A only)

1500 parts on a reel (axial lead V option

Option code

-V :

nickel plated brass end caps)

(Axial leads – copper tinned wire with

Applications

Power supplies - adapters

Desktops/notebooks

TVs / Displays

Set top boxes

Lighting ballasts

Battery chargers

Printers

Game systems

Air conditioners

Agency information

S505H-XXX-R (Cartridge)

cURus Recognition file:

E56412, Guide JFHR2,JFHR8, (500 mA - 10 A);

E19180, Guide JDYX2 and JDYX8, (12 A - 20 A)

CCC Approval: 500 mA - 10 A, Cert. No.:

2249

TUV Approval: 2 A - 10 A, Cert. No.: R50297821

PSE Approval: 1 A - 5 A, Cert. No.: JET1641-

31003-1025; 6.3 A - 10 A JET1641-31003-1023

KC Approval: SU05011-21001A (1 A - 2.5 A),

SU05011-21002A (3.15 A - 6.3 A), SU05011-

21003A (8 A -10 A), SU05011-21004A (500 mA

- 800 mA)

S505H-V-XXX-R (Axial leads)

cURus Recognition file:

E56412, Guide JFHR2,JFHR8, (500 mA - 10 A)

E19180, Guide JDYX2 and JDYX8, (12 A - 20 A)

PSE Approval: 1 A - 5 A, Cert.

No.:JET164131003-1026;

No: JET1641-31003-1024

6.3 A - 10 A, Cert.

CCC Approval: 500 mA - 10 A, Cert. No.:

2249

TUV Approval: 500 mA-10 A, Cert. No.:

R50297821

KC Approval: SU05011-21001A (1 A - 2.5 A),

SU05011-21002A (3.15 A - 6.3 A), SU05011-

21003A (8 A -10 A), SU05011-21004A (500 mA

- 800 mA)

Environmental compliance

Pb

HF

HALOGEN

FREE

Technical Data 4406

Effective June 2023

S505H

5 mm x 20 mm 400 Vdc/500-600 Vac time-delay fuse

Electrical characteristics

Amp Rating

1.5 In

minimum

minutes

2.1 In

maximum

minutes

2.75 In

minimum

ms

maximum

seconds

4.0 In

minimum

ms

maximum

seconds

10 In

mimimum

ms

maximum

ms

500 mA - 1 A

1 A - 3.15 A

4 A -6.3 A

8 A -10 A

12 A - 20 A

60

60

60

30

30*

30

30

30

30

30

250

750

750

750

750

80

80

80

80

80

50

95

150

150

150

5

5

5

5

8

5

10

10

10

10

150

150

150

150

150

* 1.5 In rating for cartridge version only

Product specifications

Part number

Current

rating

(A)

Voltage rating

1

(Vac)(Vdc)

Interrupting rating @ rated voltage

(A) @ (A) @ (A) @

250 Vac

2

600 Vac

3

400 Vdc

4

Typical DC

cold resistance

5

(Ω)

Typical

voltage drop

6

(mV)

Typical

melting

7

I

2

t (A

2

s)

Agency approvals

250 Vac

TuvCCCPSE/JETcURus

9

S505H(-V)-500-R

S505H(-V)-800-R

S505H(-V)-1-R

S505H(-V)-1.25-R

S505H(-V)-1.6-R

S505H(-V)-2-R

S505H(-V)-2.5-R

S505H(-V)-3.15-R

S505H(-V)-4-R

S505H(-V)-5-R

S505H(-V)-6.3-R

S505H(-V)-8-R

S505H(-V)-10-R

S505H(-V)-12-R

S505H(-V)-15-R

S505H(-V)-16-R

S505H(-V)-20-R

0.5

0.8

1

1.25

1.6

2

2.5

3.15

4

5

6.3

8

10

12

15

16

20

600

600

600

600

600

600

600

600

600

600

500

500

500

500

500

500

500

400

400

400

400

400

400

400

400

400

400

400

400

400

400

400

400

na

1500

1500

1500

1500

1500

1500

1500

1500

1500

1500

1500

1500

1500

na

na

na

na

100

100

100

100

100

100

100

100

100

100

100 @ 500 Vac

100 @ 500 Vac

100 @ 500 Vac

200 @ 500 Vac

200 @ 500 Vac

200 @ 500 Vac

200 @ 500 Vac

1500

1500

1500

1500

1500

1500

1500

1500

1500

1500

1500

1500

1500

300

300

300

na

0.507

0.237

0.157

0.108

0.070

0.055

0.040

0.031

0.019

0.015

0.011

0.007

0.006

0.00545

0.004

0.0037

0.00325

295

189

176

150

125

128

126

121

90

89

80

76

72

80

75

68

75

0.188

0.632

1.28

2.22

6.78

11.44

24.23

43.55

38.45

71.30

111.4

228.2

349.5

550

900

1100

1500

x

8

x

8

x

8

x

8

x

8

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

1. Voltage rating: based on the interrupting rating test according to UL.

2. Interrupting rating of 250 Vac/1500 A is tested by all agency approvals, test

condition is 250 Vac, PF: 0.7 - 0.8.

3. Interrupting rating of Vac is tested with, PF:1.0 (500 mA - 5 A @ 600 Vac, 6.3 A - 20 A @ 500

Vac)

4. Interrupting rating of Vdc is tested under capacitor bank for 500 mA to 10A; Vdc interrupting

rating for 12 A– 20 A is tested under power supply with time constant less than 1 ms.

5. Typical cold resistance measured at <10% rated current.

6. Typical voltage drop measured under ambient +20 °C with rated current

7. Typical melting I

2

t: Measured at 10 In DC

8. Axial lead version only.

9. 600/500 Vac, 400 Vdc.

2

/electronics

2024年3月13日发(作者:袁天华)

Technical Data 4406

Effective June 2023

Supersedes November 2021

S505H

5 mm x 20 mm 400 Vdc/500-600 Vac time-delay fuse

Product features

400 Vdc/500-600 Vac rating

Time-delay, high breaking capacity

5 mm x 20 mm physical size

Ceramic tube with plated end cap

construction

Designed to IEC 60127-2, Standard, Sheet 5

Optional axial leads available

Fuse accesories guide (holders, clips)

Ordering part number

the “

The ordering code is the part number replacing

.” with a “-”

BK-S505H-V-6-3-R

Packaging prefix

Family name

Option code (V = axial leaded)

Ampere rating

RoHS compliance

Packaging prefix

Blank:

lead parts in a 5 inch tin) (Values < 12 A only)

5 cartridge parts in a 5 inch tin, 4 axial

BK-:

(axial leaded only)

100 parts packed in a cardboard carton

BK1-:

sion only)

1000 parts in a poly bag (cartridge ver-

TR2-

only, values < 12 A only)

1500 parts on a reel (axial lead V option

Option code

-V :

nickel plated brass end caps)

(Axial leads – copper tinned wire with

Applications

Power supplies - adapters

Desktops/notebooks

TVs / Displays

Set top boxes

Lighting ballasts

Battery chargers

Printers

Game systems

Air conditioners

Agency information

S505H-XXX-R (Cartridge)

cURus Recognition file:

E56412, Guide JFHR2,JFHR8, (500 mA - 10 A);

E19180, Guide JDYX2 and JDYX8, (12 A - 20 A)

CCC Approval: 500 mA - 10 A, Cert. No.:

2249

TUV Approval: 2 A - 10 A, Cert. No.: R50297821

PSE Approval: 1 A - 5 A, Cert. No.: JET1641-

31003-1025; 6.3 A - 10 A JET1641-31003-1023

KC Approval: SU05011-21001A (1 A - 2.5 A),

SU05011-21002A (3.15 A - 6.3 A), SU05011-

21003A (8 A -10 A), SU05011-21004A (500 mA

- 800 mA)

S505H-V-XXX-R (Axial leads)

cURus Recognition file:

E56412, Guide JFHR2,JFHR8, (500 mA - 10 A)

E19180, Guide JDYX2 and JDYX8, (12 A - 20 A)

PSE Approval: 1 A - 5 A, Cert.

No.:JET164131003-1026;

No: JET1641-31003-1024

6.3 A - 10 A, Cert.

CCC Approval: 500 mA - 10 A, Cert. No.:

2249

TUV Approval: 500 mA-10 A, Cert. No.:

R50297821

KC Approval: SU05011-21001A (1 A - 2.5 A),

SU05011-21002A (3.15 A - 6.3 A), SU05011-

21003A (8 A -10 A), SU05011-21004A (500 mA

- 800 mA)

Environmental compliance

Pb

HF

HALOGEN

FREE

Technical Data 4406

Effective June 2023

S505H

5 mm x 20 mm 400 Vdc/500-600 Vac time-delay fuse

Electrical characteristics

Amp Rating

1.5 In

minimum

minutes

2.1 In

maximum

minutes

2.75 In

minimum

ms

maximum

seconds

4.0 In

minimum

ms

maximum

seconds

10 In

mimimum

ms

maximum

ms

500 mA - 1 A

1 A - 3.15 A

4 A -6.3 A

8 A -10 A

12 A - 20 A

60

60

60

30

30*

30

30

30

30

30

250

750

750

750

750

80

80

80

80

80

50

95

150

150

150

5

5

5

5

8

5

10

10

10

10

150

150

150

150

150

* 1.5 In rating for cartridge version only

Product specifications

Part number

Current

rating

(A)

Voltage rating

1

(Vac)(Vdc)

Interrupting rating @ rated voltage

(A) @ (A) @ (A) @

250 Vac

2

600 Vac

3

400 Vdc

4

Typical DC

cold resistance

5

(Ω)

Typical

voltage drop

6

(mV)

Typical

melting

7

I

2

t (A

2

s)

Agency approvals

250 Vac

TuvCCCPSE/JETcURus

9

S505H(-V)-500-R

S505H(-V)-800-R

S505H(-V)-1-R

S505H(-V)-1.25-R

S505H(-V)-1.6-R

S505H(-V)-2-R

S505H(-V)-2.5-R

S505H(-V)-3.15-R

S505H(-V)-4-R

S505H(-V)-5-R

S505H(-V)-6.3-R

S505H(-V)-8-R

S505H(-V)-10-R

S505H(-V)-12-R

S505H(-V)-15-R

S505H(-V)-16-R

S505H(-V)-20-R

0.5

0.8

1

1.25

1.6

2

2.5

3.15

4

5

6.3

8

10

12

15

16

20

600

600

600

600

600

600

600

600

600

600

500

500

500

500

500

500

500

400

400

400

400

400

400

400

400

400

400

400

400

400

400

400

400

na

1500

1500

1500

1500

1500

1500

1500

1500

1500

1500

1500

1500

1500

na

na

na

na

100

100

100

100

100

100

100

100

100

100

100 @ 500 Vac

100 @ 500 Vac

100 @ 500 Vac

200 @ 500 Vac

200 @ 500 Vac

200 @ 500 Vac

200 @ 500 Vac

1500

1500

1500

1500

1500

1500

1500

1500

1500

1500

1500

1500

1500

300

300

300

na

0.507

0.237

0.157

0.108

0.070

0.055

0.040

0.031

0.019

0.015

0.011

0.007

0.006

0.00545

0.004

0.0037

0.00325

295

189

176

150

125

128

126

121

90

89

80

76

72

80

75

68

75

0.188

0.632

1.28

2.22

6.78

11.44

24.23

43.55

38.45

71.30

111.4

228.2

349.5

550

900

1100

1500

x

8

x

8

x

8

x

8

x

8

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

1. Voltage rating: based on the interrupting rating test according to UL.

2. Interrupting rating of 250 Vac/1500 A is tested by all agency approvals, test

condition is 250 Vac, PF: 0.7 - 0.8.

3. Interrupting rating of Vac is tested with, PF:1.0 (500 mA - 5 A @ 600 Vac, 6.3 A - 20 A @ 500

Vac)

4. Interrupting rating of Vdc is tested under capacitor bank for 500 mA to 10A; Vdc interrupting

rating for 12 A– 20 A is tested under power supply with time constant less than 1 ms.

5. Typical cold resistance measured at <10% rated current.

6. Typical voltage drop measured under ambient +20 °C with rated current

7. Typical melting I

2

t: Measured at 10 In DC

8. Axial lead version only.

9. 600/500 Vac, 400 Vdc.