Cleanliness of components of fluid circuits

ISO 16232

C L A R I F I C A T I O N L I S T

File-Name: Abklärungsbogen_eng

page 1 of 2

General information:

Customer:

Contact person:

E-mail:

Laboratory information:

Offer No:

PO:

No. of analyses:

Component name,

item number,

drawing number:

Components per

test lot (< 200 cm²)

Surface from CAD:

[cm²]

Particle counting

from size: [µm]

Evaluation:

[µm/Pixel]

Sampled area:

- Complete

- Partial, descr.:

ISO 16232:2007 and VDA 19.1:2015

Gravimetric

analysis:

- mg/part

- mg/1000 cm²

Test standard,

specification:

Nominal pore size,

? µm open mesh fabric

Filter material:

Pictures of largest

particles in report:

Metal:

Nonmetal:

Fibres:

per part

CCC = C

coded

2 pcs.

2 pcs.

2 pcs.

per part

CCC = N

uncoded

Cleanliness code,

Cleanliness class:

Rating: - Metal particles

per

1000 cm²

CCC = A

coded

per

100 ml

CCC = V

coded

- Nonmetal particles

- Test bench CTU, fan/round nozzle, flow rate?

- LDG pressure rinsing, round nozzle, flow rate?

- Ultrasonic, 35 kHz, ? Watt/l,

- Dipping bath, ? second

- Shaking (inner space), ? minute

- Rinsing (tubes), ? Ø, ? ml/min

- Compiled, No: E

- To compile: 2 test lots required! Retention of

- None, parameters by specification components:

- None, first cut analysis

- English - German Mail-order

- Fibres

Cleaning process:

- Solvent cleaners,

DeSolvIt 1000

- Water demin.

with detergent

- Propyl alcohol 50 %

- Other:

- Return to sender

- Scrapping

- E-Mail

Extraction curve:

Report:

Expected shipping date:

Customer (date, name):

Appointment for result:

Laboratory (date, name):

Accredited testing laboratory according to DIN EN ISO/IEC 17025 by DAkkS.

Accreditation applies to procedures listed in the certificate.

The accreditation is valid for the test method ISO 16232, part 3-7.

HypoVereinsbank Herzogenaurach SWIFT (BIC): HYVEDEMM417

Account No.: 16 904 511 IBAN: DE32 7632 0072 0016 9045 11

Bank code: 763 200 72 Register court: Amtsgericht Fürth

VAT No.: DE 815330348 Commercial register-No. HRB 13281

Managing partner:

Dr. Thomas Wirkner, Dipl. Chem.

Christian Schad, Dipl.-Ing. (FH)

Dr. Thomas Fürst, Dipl. Chem.

Formular: _AAB_Clarification List_Version_8, valid from: 23.11.2015

Cleanliness of components of fluid circuits

ISO 16232

C L A R I F I C A T I O N L I S T

File-Name: Abklärungsbogen_eng

page 2 of 2

Other customer information insofar relevant for the testing:

Materials:

Preservatives :

Packaging:

Preparation of the

components before testing:

Components after testing:

- Packaging original

- Isolation of areas

- Preservatives

- PE bag

- Dismanting

Sampled subarea:

Volume:

- Packaging or container rinsing

- Demagnetising

[cm²]

[cm³]

- Local precleaning

Information about the test cleaning process by Analytik Aurachtal

Contamination Test Unit Hydac 1000

Tank pressure:

Round Nozzle,

Ø 2.5 mm

Fan Nozzle,

Ø 1.5 mm

Medium:

Environment: Clean box, Holten Lamin Air, Class type II

Pressure rinsing with LDG spray gun

Tank pressure: 1 – 2 bar

Nozzle Steel: Round, Ø 0.41 – 2.5 mm

Flow rate: 100 – 1500 ml/min

Medium A : CH-Solvent: DeSolvIt 1000

Medium B: Water demin. with detergent

Medium C: propyl alcohol 50 %

Filtration

Sartorius, pressure filtration, 200 ml

Medium: clean Argon

5 µm CN

membrane

filter

5 µm PETEX

open mesh

fabric

Drying cabinet:: 100°C / 60 min.

Exsiccator: RT / 60 min.

50 µm PES

open mesh

fabric

Ultrasonic extraction

~ 2.3 bar

2 l/min

1.5 l/min

CH-Solvent:

DESolvIT 1000

Equipment: Sonorex

RK 1050

Power: 35 kHz

15-25 Watt/l

Filter, material,

nominal pore size:

Gravimetric analysis:

Balance:

15 µm PETEX 20 µm PETEX

open mesh

fabric

open mesh

fabric

TYP Denver TB 215D Accuracy of the balance: +/- 0.01 mg

Min. contaminant mass: 0.3 mg

Blank value: < 0.1 mg

Standard analysis

VDA 19.1 (1:10)

from size class E

from size class C

from size class C

from size class B

J K

L M N

2000 3000

- -

3000 >

Particle counting (APC): dhs-Cleanalizer II Professional, with polarizing filter:

Objektive lens

AA 0.75

AA 2.00

AA 3.00

AA 5.00

Resolution

3.5 µm/pixel

1.3 µm/pixel

0.9 µm/pixel

0.5 µm/pixel

E

50

-

100

F

100

-

150

G

150

-

200

ISO 16232 (1:5)

from size class D

from size class C

from size class B

from size class B

H

200

-

400

I

400

-

600

Size class:

Particle size:

[µm]

B

5

-

15

C

15

-

25

D

25

-

50

600 > 1000

1500

- -

-

1000 (1500)

2000

HypoVereinsbank Herzogenaurach

Account No.: 16 904 511

Bank Code: 763 200 72

VAT No.: DE 815330348

SWIFT (BIC): HYVEDEMM417

IBAN: DE32 7632 0072 0016 9045 11

Register Court: Amtsgericht Fürth

Commercial register-No. HRB 13281

Managing Partner:

Dr. Thomas Wirkner, Dipl. Chem.

Christian Schad, Dipl.-Ing. (FH)

Dr. Thomas Fürst, Dipl. Chem.

2024年4月12日发(作者:昂冰莹)

Cleanliness of components of fluid circuits

ISO 16232

C L A R I F I C A T I O N L I S T

File-Name: Abklärungsbogen_eng

page 1 of 2

General information:

Customer:

Contact person:

E-mail:

Laboratory information:

Offer No:

PO:

No. of analyses:

Component name,

item number,

drawing number:

Components per

test lot (< 200 cm²)

Surface from CAD:

[cm²]

Particle counting

from size: [µm]

Evaluation:

[µm/Pixel]

Sampled area:

- Complete

- Partial, descr.:

ISO 16232:2007 and VDA 19.1:2015

Gravimetric

analysis:

- mg/part

- mg/1000 cm²

Test standard,

specification:

Nominal pore size,

? µm open mesh fabric

Filter material:

Pictures of largest

particles in report:

Metal:

Nonmetal:

Fibres:

per part

CCC = C

coded

2 pcs.

2 pcs.

2 pcs.

per part

CCC = N

uncoded

Cleanliness code,

Cleanliness class:

Rating: - Metal particles

per

1000 cm²

CCC = A

coded

per

100 ml

CCC = V

coded

- Nonmetal particles

- Test bench CTU, fan/round nozzle, flow rate?

- LDG pressure rinsing, round nozzle, flow rate?

- Ultrasonic, 35 kHz, ? Watt/l,

- Dipping bath, ? second

- Shaking (inner space), ? minute

- Rinsing (tubes), ? Ø, ? ml/min

- Compiled, No: E

- To compile: 2 test lots required! Retention of

- None, parameters by specification components:

- None, first cut analysis

- English - German Mail-order

- Fibres

Cleaning process:

- Solvent cleaners,

DeSolvIt 1000

- Water demin.

with detergent

- Propyl alcohol 50 %

- Other:

- Return to sender

- Scrapping

- E-Mail

Extraction curve:

Report:

Expected shipping date:

Customer (date, name):

Appointment for result:

Laboratory (date, name):

Accredited testing laboratory according to DIN EN ISO/IEC 17025 by DAkkS.

Accreditation applies to procedures listed in the certificate.

The accreditation is valid for the test method ISO 16232, part 3-7.

HypoVereinsbank Herzogenaurach SWIFT (BIC): HYVEDEMM417

Account No.: 16 904 511 IBAN: DE32 7632 0072 0016 9045 11

Bank code: 763 200 72 Register court: Amtsgericht Fürth

VAT No.: DE 815330348 Commercial register-No. HRB 13281

Managing partner:

Dr. Thomas Wirkner, Dipl. Chem.

Christian Schad, Dipl.-Ing. (FH)

Dr. Thomas Fürst, Dipl. Chem.

Formular: _AAB_Clarification List_Version_8, valid from: 23.11.2015

Cleanliness of components of fluid circuits

ISO 16232

C L A R I F I C A T I O N L I S T

File-Name: Abklärungsbogen_eng

page 2 of 2

Other customer information insofar relevant for the testing:

Materials:

Preservatives :

Packaging:

Preparation of the

components before testing:

Components after testing:

- Packaging original

- Isolation of areas

- Preservatives

- PE bag

- Dismanting

Sampled subarea:

Volume:

- Packaging or container rinsing

- Demagnetising

[cm²]

[cm³]

- Local precleaning

Information about the test cleaning process by Analytik Aurachtal

Contamination Test Unit Hydac 1000

Tank pressure:

Round Nozzle,

Ø 2.5 mm

Fan Nozzle,

Ø 1.5 mm

Medium:

Environment: Clean box, Holten Lamin Air, Class type II

Pressure rinsing with LDG spray gun

Tank pressure: 1 – 2 bar

Nozzle Steel: Round, Ø 0.41 – 2.5 mm

Flow rate: 100 – 1500 ml/min

Medium A : CH-Solvent: DeSolvIt 1000

Medium B: Water demin. with detergent

Medium C: propyl alcohol 50 %

Filtration

Sartorius, pressure filtration, 200 ml

Medium: clean Argon

5 µm CN

membrane

filter

5 µm PETEX

open mesh

fabric

Drying cabinet:: 100°C / 60 min.

Exsiccator: RT / 60 min.

50 µm PES

open mesh

fabric

Ultrasonic extraction

~ 2.3 bar

2 l/min

1.5 l/min

CH-Solvent:

DESolvIT 1000

Equipment: Sonorex

RK 1050

Power: 35 kHz

15-25 Watt/l

Filter, material,

nominal pore size:

Gravimetric analysis:

Balance:

15 µm PETEX 20 µm PETEX

open mesh

fabric

open mesh

fabric

TYP Denver TB 215D Accuracy of the balance: +/- 0.01 mg

Min. contaminant mass: 0.3 mg

Blank value: < 0.1 mg

Standard analysis

VDA 19.1 (1:10)

from size class E

from size class C

from size class C

from size class B

J K

L M N

2000 3000

- -

3000 >

Particle counting (APC): dhs-Cleanalizer II Professional, with polarizing filter:

Objektive lens

AA 0.75

AA 2.00

AA 3.00

AA 5.00

Resolution

3.5 µm/pixel

1.3 µm/pixel

0.9 µm/pixel

0.5 µm/pixel

E

50

-

100

F

100

-

150

G

150

-

200

ISO 16232 (1:5)

from size class D

from size class C

from size class B

from size class B

H

200

-

400

I

400

-

600

Size class:

Particle size:

[µm]

B

5

-

15

C

15

-

25

D

25

-

50

600 > 1000

1500

- -

-

1000 (1500)

2000

HypoVereinsbank Herzogenaurach

Account No.: 16 904 511

Bank Code: 763 200 72

VAT No.: DE 815330348

SWIFT (BIC): HYVEDEMM417

IBAN: DE32 7632 0072 0016 9045 11

Register Court: Amtsgericht Fürth

Commercial register-No. HRB 13281

Managing Partner:

Dr. Thomas Wirkner, Dipl. Chem.

Christian Schad, Dipl.-Ing. (FH)

Dr. Thomas Fürst, Dipl. Chem.

发布评论

评论列表 (0)

  1. 暂无评论