GETTING STARTED GUIDE

PXIe-5785

12-Bit, 6.4 GS/s, 2-Channel PXI FlexRIO IF Transceiver

This document explains how to install, configure, test, and use the PXIe-5785. You can

program the PXIe-5785 with the following software options.

•FlexRIO driver software

•NI LabVIEW Instrument Design Libraries for FlexRIO (instrument design libraries)

Note

Before you begin, install and configure your chassis and controller.

Note

Adapter modules are not installable or interchangeable on PXIe-5785

devices.

Contents

FlexRIO Documentation 2

Verifying the 2

Unpacking 3

PXIe-5785 3

Preparing 4

Installing the Software 4

Installing .5

PXIe-5785 6

Configuring the PXIe-5785 8

9

Accessing 9

9

Component-Level Intellectual Property (CLIP)......................................................................11

Making .12

Making a Measurement 12

12

What Should I Do if the PXIe-5785 Doesn't Appear in MAX?......................................12

What Should I Do if the PXIe-5785 Fails the Self-Test?................................................12

Where to 13

Worldwide Support 13

FlexRIO Documentation and Resources

Table 1. FlexRIO Documentation and Resources

Document/ResourceLocationDescription

PXIe-5785 Getting

Started Guide (this

document)

PXIe-5785

Specifications

PXIe-5785 Safety,

Environmental, and

Regulatory Information

Available at /

manuals.

Available at /

manuals.

Available at /

manuals.

Contains installation instructions and

basic programming instructions for

your PXIe-5785.

Contains specifications for your

PXIe-5785.

Contains important safety,

environmental, and regulatory

information for your PXIe-5785.

Contains information about the basic

functionality of the LabVIEW FPGA

Module.

Contains information about the FPGA

module front panel connectors and

I/O, programming instructions, and

I/O component-level IP (CLIP).

Contains examples of how to run

FPGA VIs and Host VIs on your

device.

LabVIEW FPGA ModuleEmbedded in LabVIEW

HelpHelp and at /

manuals.

FlexRIO HelpAvailable at /

manuals.

LabVIEW ExamplesAvailable in NI Example

Finder. In LabVIEW,

click Help»Find

Examples»Hardware

Input and Output»

FlexRIO.

Located at /

FlexRIO product page

Contains LabVIEW FPGA functions

and intellectual property to share.

Located at /ns product information and

data sheets for FlexRIO devices.

Verifying the System Requirements

To use the PXIe-5785, your system must meet certain requirements. For more information

about minimum system requirements, recommended system, and supported application

development environments (ADEs), refer to the readme, which is available on the software

media or online at /updates.

2 | | PXIe-5785 Getting Started Guide

Unpacking the Kit

Notice

To prevent electrostatic discharge (ESD) from damaging the device, ground

1.

2.

yourself using a grounding strap or by holding a grounded object, such as your

computer chassis.

Touch the antistatic package to a metal part of the computer chassis.

Remove the device from the package and inspect the device for loose components or any

other sign of damage.

Notice

Never touch the exposed pins of connectors.

Note

Do not install a device if it appears damaged in any way.

any other items and documentation from the kit.

Store the device in the antistatic package when the device is not in use.

PXIe-5785 Kit Contents

The following items are included in the device kit:

•PXIe-5785

•FlexRIO driver software media

•Documentation:

–Maintain Forced-Air Cooling Note to Users

–PXIe-5785 Getting Started Guide (this document)

–PXIe-5785 Safety, Environmental, and Regulatory Information

PXIe-5785 Getting Started Guide | © National Instruments | 3

Preparing the Environment

Ensure the environment in which you are using the PXIe-5785 meets the following

specifications.

Operating environment

Ambient temperature range0 °C to 55 °C

1

(Tested in accordance with

IEC-60068-2-1 and IEC-60068-2-2. Meets

MIL-PRF-28800F Class 3 low temperature

limit and MIL-PRF-28800F Class 2 high

temperature limit.)

10% to 90%, noncondensing (Tested in

accordance with IEC 60068-2-56.)

2,000 m (800 mbar) (at 25 °C ambient

temperature)

2

Relative humidity range

Maximum altitude

Pollution Degree

Indoor use only.

Note

For complete specifications, refer to the specifications document for your

device at /manuals.

Installing the Software and Driver

Before installing your hardware, you must install the application software and instrument

driver. Visit NI FlexRIO Driver Supported Versions for FlexRIO Adapters and Modules to

determine which minimum software versions you need for your device. Install the software in

the following order:

l LabVIEW.

Refer to the LabVIEW Installation Guide for installation instructions for LabVIEW and

system requirements for the LabVIEW software. Refer to the LabVIEW Upgrade Notes

for additional information about upgrading to the most recent version of LabVIEW for

Windows. Documentation for LabVIEW is available at /manuals.

l the LabVIEW FPGA Module.

Refer to the LabVIEW FPGA Module Release and Upgrade Notes for installation

instructions and information about getting started with the LabVIEW FPGA Module.

Documentation for the LabVIEW FPGA Module is available at /manuals.

3.

1

(Optional) Install the LabVIEW Real-Time Module.

The PXIe-5785 requires a chassis with slot cooling capacity ≥58 W. Not all chassis with slot

cooling capacity ≥58 W can achieve this ambient temperature range. Refer to the PXI Chassis

Manual for specifications to determine the ambient temperature ranges your chassis can achieve.

4 | | PXIe-5785 Getting Started Guide

Refer to the LabVIEW Real-Time Module Release and Upgrade Notes for system

requirements, installation instructions, and additional information about using the

LabVIEW Real-Time Module.

l FlexRIO.

Refer to the FlexRIO Readme for system requirements and installation instructions for

FlexRIO. Documentation for FlexRIO is available at /manuals.

Installing the PXIe-5785

Notice

To prevent damage to the PXIe-5785 caused by ESD or contamination,

1.

handle the module using the edges or the metal bracket.

Ensure the AC power source is connected to the chassis before installing the module.

The AC power cord grounds the chassis and protects it from electrical damage while you

install the module.

2.

3.

4.

5.

Power off the chassis.

Inspect the slot pins on the chassis backplane for any bends or damage prior to

installation. Do not install a module if the backplane is damaged.

Remove the black plastic covers from all the captive screws on the module front panel.

Identify a supported slot in the chassis. The following figure shows the symbols that

indicate the slot types.

Figure 1. Chassis Compatibility Symbols

1

23

4

5

Express System Controller Slot

Peripheral Slot

Express Hybrid Peripheral Slot

Express System Timing Slot

Express Peripheral Slot

PXIe-5785 modules can be placed in PXI Express peripheral slots, PXI Express hybrid

peripheral slots, or PXI Express system timing slots.

6.

7.

8.

Touch any metal part of the chassis to discharge static electricity.

Ensure that the ejector handle is in the downward (unlatched) position.

Place the module edges into the module guides at the top and bottom of the chassis. Slide

the module into the slot until it is fully inserted.

PXIe-5785 Getting Started Guide | © National Instruments | 5

Figure 2. Module Installation

1

0

2

3

s

re Module

r Handle in Downward (Unlatched) Position

the module in place by pulling up on the ejector handle.

Note

Tightening the top and bottom mounting screws increases mechanical

the module front panel to the chassis using the front-panel mounting screws.

stability and also electrically connects the front panel to the chassis, which can

improve the signal quality and electromagnetic performance.

all empty slots using EMC filler panels or fill using slot blockers to maximize

cooling air flow, depending on your application.

on the chassis.

PXIe-5785 Front Panel

The following figure shows the PXIe-5785 front panel.

6 | | PXIe-5785 Getting Started Guide

Figure 3. PXIe-5785 Front Panel

PXIe-5785

FlexRIO IF Transceiver

DIO

12-Bit, 6.4 GS/s

4 Vpp

MAX

AI 0

AI 1

AO 0

AO 1

4 Vpp

MAX

REF/

CLK IN

The following table describes the signal connections for the PXIe-5785.

ConnectorDescriptionFunction

DIO

Molex Nano-Pitch DIO

connector

Multi-signal DIO connector that provides

access to FPGA multi-gigabit transceivers

(MGTs) and general-purpose LVCMOS

signals.

Analog input 0:1Standard SMA female

connector

PXIe-5785 Getting Started Guide | © National Instruments | 7

ConnectorDescriptionFunction

AO 0:1

Standard SMA female

connector

Analog output connection.

Input for an external Reference Clock or

Sample Clock.

REF/CLK INStandard SMA female

connector

The following table lists the available pins on the DIO connector.

SignalTypeDirection

MGT Tx± <3..0>

2

MGT Rx± <3..0>

2

DIO <7..0>

5.0 V

GND

Xilinx UltraScale GTH

Xilinx UltraScale GTH

Single-ended

DC

Ground

Output

Input

Bidirectional

Output

Notice

The maximum input signal levels are valid only when the module is

powered on. To avoid permanent damage to the PXIe-5785, do not apply a signal to

the device when the module is powered down.

Notice

Connections that exceed any of the maximum ratings of any connector on

the PXIe-5785 can damage the device and the chassis. NI is not liable for any

damage resulting from such connections.

Configuring the PXIe-5785 in MAX

Use Measurement & Automation Explorer (MAX) to configure your NI hardware. MAX

informs other programs about which NI hardware products are in the system and how they are

configured. MAX is automatically installed with FlexRIO.

MAX.

the configuration tree, expand Devices and Interfaces to see the list of installed NI

hardware.

Installed modules appear under the name of their associated chassis.

your Chassis tree item.

2

MGTs are available only on devices with KU040 and KU060 FPGAs.

8 | | PXIe-5785 Getting Started Guide

MAX lists all modules installed in the chassis. Your default names may vary.

Note

If you do not see your module listed, press to refresh the list of

installed modules. If the module is still not listed, power off the system, ensure

the module is correctly installed, and restart.

4.

5.

Record the identifier MAX assigns to the hardware. Use this identifier when

programming the PXIe-5785.

Self-test the hardware by selecting the item in the configuration tree and clicking Self-

Test in the MAX toolbar.

The MAX self-test performs a basic verification of hardware resources.

FlexRIO Examples

FlexRIO includes several example applications for LabVIEW. These examples serve as

interactive tools, programming models, and as building blocks in your own applications.

Accessing FlexRIO Examples

FlexRIO examples are available in LabVIEW's NI Example Finder. Complete the following

steps to access the examples by task.

LabVIEW, click Help»Find Examples.

the NI Example Finder window that appears, click Hardware Input and Output»

FlexRIO.

The examples are sorted by task. Click on an example and refer to the Information

window for a description of the example. Refer the Requirements window for a list of

hardware devices that can run the example.

You can also click the Search tab to search all installed examples by keyword. For

example, search for

FlexRIO

to locate all FlexRIO examples.

Examples also are available online that demonstrate FlexRIO basics, such as using DRAM,

acquiring data from adapter modules, and performing high throughput streaming. Refer to

/examples for these examples and for more information.

Block Diagram

The following figure shows a block diagram of the carrier portion of the PXIe-5785 (KU035

FPGA option).

PXIe-5785 Getting Started Guide | © National Instruments | 9

Figure 4. Carrier Block Diagram (KU035)

Power Supplies

D

I

O

C

o

n

n

e

c

t

o

r

(

F

r

o

n

t

P

a

n

e

l

)

+5 V

+12 V

+12 V, +3.3 V

Gen3 x8 PCIe

DStarB, DStarC

PXI Triggers

GPIO

+1.8 V

+12 V

FPGA

Clk 100

Clk 10

MGTs

Module Clocking

Synchronization

A

d

a

p

t

e

r

M

o

d

u

l

e

C

o

n

n

e

c

t

o

r

Configuration, GPIO

Reference Clock

The following figure shows a block diagram of the carrier portion of the PXIe-5785 (KU040

and KU060 FPGA options).

Figure 5. Carrier Block Diagram (KU040 and KU060)

Power Supplies

D

I

O

C

o

n

n

e

c

t

o

r

(

F

r

o

n

t

P

a

n

e

l

)

+5 V

+12 V

+12V, +3.3 V

Flash

GPIO

MGTs

+1.8 V

+12 V

Gen3 x8 PCIe

DStarB, DStarC

FPGA

PXITriggers

Clk 100

Clk 10

A

d

a

p

t

e

r

M

o

d

u

l

e

C

o

n

n

e

c

t

o

r

Configuration, GPIO

MGTs

Module Clocking

Synchronization

DRAM Bank 0

(2 GB)

Reference Clock

DRAM Bank 1

(2 GB)

The following figure shows a block diagram of the I/O portion of the PXIe-5785.

10 | | PXIe-5785 Getting Started Guide

P

X

I

e

C

o

n

n

e

c

t

o

r

s

P

X

I

e

C

o

n

n

e

c

t

o

r

s

Flash

Figure 6. PXIe-5785 Block Diagram

ADC12DJ3200

Dual 12-bit, 3.2 GS/s

Single 12-bit, 6.4 GS/s

ANALOG INPUT

AI0 SMA

AC (Balun)

Coupled Path

AI1 SMA

AC (Balun)

Coupled Path

ANALOG OUTPUT

AO0 SMA

Optional

Anti-Image Filter

AC (Balun)

Coupled Path

Adapter Module

Connector

AO1 SMA

Optional

Anti-Image Filter

AC (Balun)

Coupled Path

CLOCKING

EXTERNAL REF/SCLK

CLK IN SMA

DAC38RF82

Dual 12-bit, 6.4 GS/s

Component-Level Intellectual Property (CLIP)

The LabVIEW FPGA Module includes component-level intellectual property (CLIP) for HDL

IP integration. FlexRIO devices support two types of CLIP: user-defined and socketed.

•User-defined CLIP allows you to insert HDL IP into an FPGA target, enabling VHDL

code to communicate directly with an FPGA VI.

•Socketed CLIP provides the same IP integration of the user-defined CLIP, but it also

allows the CLIP to communicate directly with circuitry external to the FPGA. Adapter

module socketed CLIP allows your IP to communicate directly with both the FPGA VI

and the external adapter module connector interface.

The PXIe-5785 ships with socketed CLIP items that add module I/O to the LabVIEW project.

PXIe-5785 Getting Started Guide | © National Instruments | 11

Making a Measurement

Making a Measurement with LabVIEW

1.

2.

3.

4.

Launch LabVIEW.

Select Help»Find Example.

Open the example VI that you want to use by selecting Hardware Input and Output»

FlexRIO.

Follow any setup, configuration, and execution instructions in the VI.

Troubleshooting

If an issue persists after you complete a troubleshooting procedure, contact NI technical

support or visit /support.

What Should I Do if the PXIe-5785 Doesn't Appear in

MAX?

1.

2.

3.

4.

In the MAX configuration tree, expand Devices and Interfaces.

Expand the Chassis tree to see the list of installed hardware, and press to refresh

the list.

If the module is still not listed, power off the system, ensure that all hardware is correctly

installed, and restart the system.

Navigate to the Device Manager.

Operating System

Windows 10/8.1

Windows 7

5.

Description

Right-click the Start button, and select Device Manager.

Select Start»Control Panel»Device Manager.

Verify the PXIe-5785 appears in the Device Manager.

a)Under an NI entry, confirm that a PXIe-5785 entry appears.

Note

If you are using a PC with a device for PXI remote control system,

b)

under System Devices, also confirm that no error conditions appear for the

PCI-to-PCI Bridge.

If error conditions appear, reinstall FlexRIO and the PXIe-5785.

What Should I Do if the PXIe-5785 Fails the Self-Test?

1.

2.

3.

4.

Restart the system.

Launch MAX, and perform the self-test again.

Power off the chassis.

Reinstall the failed module in a different slot.

12 | | PXIe-5785 Getting Started Guide

5.

6.

Power on the chassis.

Perform the self-test again.

Where to Go Next

Refer to the following figure for information about other product tasks and associated

resources for those tasks.

Located online at /manualsLocated using the NI Example Finder

EXPLORE

the application development

environment (ADE)

for your application.

LEARN

about hardware features

or review device

specifications.

CREATE

custom applications with

an application programming

interface (API).

Learn LabVIEW Basics

LabVIEW FPGA

Module Help

PXIe-5785

Specifications*

FlexRIO Module

Examples*

FlexRIO Help*

DISCOVER

more about your products through .

Support

/support

FlexRIO

/flexrio

Services

/services

NI Community

/community

*This item is also installed with the driver software.

Worldwide Support and Services

The NI website is your complete resource for technical support. At /support, you have

access to everything from troubleshooting and application development self-help resources to

email and phone assistance from NI Application Engineers.

Visit /services for information about the services NI offers.

Visit /register to register your NI product. Product registration facilitates technical

support and ensures that you receive important information updates from NI.

NI corporate headquarters is located at 11500 North Mopac Expressway, Austin, Texas,

78759-3504. NI also has offices located around the world. For support in the United States,

create your service request at /support or dial 1 866 ASK MYNI (275 6964). For

PXIe-5785 Getting Started Guide | © National Instruments | 13

support outside the United States, visit the Worldwide Offices section of /niglobal to

access the branch office websites, which provide up-to-date contact information.

Information is subject to change without notice. Refer to the NI Trademarks and Logo Guidelines at

/trademarks

for

information on NI trademarks. Other product and company names mentioned herein are trademarks or trade names of their

respective companies. For patents covering NI products/technology, refer to the appropriate location: Help»Patents in your

software, the

file on your media, or the National Instruments Patent Notice at

/patents

. You can find

information about end-user license agreements (EULAs) and third-party legal notices in the readme file for your NI product. Refer

to the Export Compliance Information at

/legal/export-compliance

for the NI global trade compliance policy and how

to obtain relevant HTS codes, ECCNs, and other import/export data. NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS

TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS. U.S.

Government Customers: The data contained in this manual was developed at private expense and is subject to the applicable

limited rights and restricted data rights as set forth in FAR 52.227-14, DFAR 252.227-7014, and DFAR 252.227-7015.

© 2018—2019 National Instruments. All rights reserved.

376897B-01March 21, 2019

2024年7月31日发(作者:毛秋)

GETTING STARTED GUIDE

PXIe-5785

12-Bit, 6.4 GS/s, 2-Channel PXI FlexRIO IF Transceiver

This document explains how to install, configure, test, and use the PXIe-5785. You can

program the PXIe-5785 with the following software options.

•FlexRIO driver software

•NI LabVIEW Instrument Design Libraries for FlexRIO (instrument design libraries)

Note

Before you begin, install and configure your chassis and controller.

Note

Adapter modules are not installable or interchangeable on PXIe-5785

devices.

Contents

FlexRIO Documentation 2

Verifying the 2

Unpacking 3

PXIe-5785 3

Preparing 4

Installing the Software 4

Installing .5

PXIe-5785 6

Configuring the PXIe-5785 8

9

Accessing 9

9

Component-Level Intellectual Property (CLIP)......................................................................11

Making .12

Making a Measurement 12

12

What Should I Do if the PXIe-5785 Doesn't Appear in MAX?......................................12

What Should I Do if the PXIe-5785 Fails the Self-Test?................................................12

Where to 13

Worldwide Support 13

FlexRIO Documentation and Resources

Table 1. FlexRIO Documentation and Resources

Document/ResourceLocationDescription

PXIe-5785 Getting

Started Guide (this

document)

PXIe-5785

Specifications

PXIe-5785 Safety,

Environmental, and

Regulatory Information

Available at /

manuals.

Available at /

manuals.

Available at /

manuals.

Contains installation instructions and

basic programming instructions for

your PXIe-5785.

Contains specifications for your

PXIe-5785.

Contains important safety,

environmental, and regulatory

information for your PXIe-5785.

Contains information about the basic

functionality of the LabVIEW FPGA

Module.

Contains information about the FPGA

module front panel connectors and

I/O, programming instructions, and

I/O component-level IP (CLIP).

Contains examples of how to run

FPGA VIs and Host VIs on your

device.

LabVIEW FPGA ModuleEmbedded in LabVIEW

HelpHelp and at /

manuals.

FlexRIO HelpAvailable at /

manuals.

LabVIEW ExamplesAvailable in NI Example

Finder. In LabVIEW,

click Help»Find

Examples»Hardware

Input and Output»

FlexRIO.

Located at /

FlexRIO product page

Contains LabVIEW FPGA functions

and intellectual property to share.

Located at /ns product information and

data sheets for FlexRIO devices.

Verifying the System Requirements

To use the PXIe-5785, your system must meet certain requirements. For more information

about minimum system requirements, recommended system, and supported application

development environments (ADEs), refer to the readme, which is available on the software

media or online at /updates.

2 | | PXIe-5785 Getting Started Guide

Unpacking the Kit

Notice

To prevent electrostatic discharge (ESD) from damaging the device, ground

1.

2.

yourself using a grounding strap or by holding a grounded object, such as your

computer chassis.

Touch the antistatic package to a metal part of the computer chassis.

Remove the device from the package and inspect the device for loose components or any

other sign of damage.

Notice

Never touch the exposed pins of connectors.

Note

Do not install a device if it appears damaged in any way.

any other items and documentation from the kit.

Store the device in the antistatic package when the device is not in use.

PXIe-5785 Kit Contents

The following items are included in the device kit:

•PXIe-5785

•FlexRIO driver software media

•Documentation:

–Maintain Forced-Air Cooling Note to Users

–PXIe-5785 Getting Started Guide (this document)

–PXIe-5785 Safety, Environmental, and Regulatory Information

PXIe-5785 Getting Started Guide | © National Instruments | 3

Preparing the Environment

Ensure the environment in which you are using the PXIe-5785 meets the following

specifications.

Operating environment

Ambient temperature range0 °C to 55 °C

1

(Tested in accordance with

IEC-60068-2-1 and IEC-60068-2-2. Meets

MIL-PRF-28800F Class 3 low temperature

limit and MIL-PRF-28800F Class 2 high

temperature limit.)

10% to 90%, noncondensing (Tested in

accordance with IEC 60068-2-56.)

2,000 m (800 mbar) (at 25 °C ambient

temperature)

2

Relative humidity range

Maximum altitude

Pollution Degree

Indoor use only.

Note

For complete specifications, refer to the specifications document for your

device at /manuals.

Installing the Software and Driver

Before installing your hardware, you must install the application software and instrument

driver. Visit NI FlexRIO Driver Supported Versions for FlexRIO Adapters and Modules to

determine which minimum software versions you need for your device. Install the software in

the following order:

l LabVIEW.

Refer to the LabVIEW Installation Guide for installation instructions for LabVIEW and

system requirements for the LabVIEW software. Refer to the LabVIEW Upgrade Notes

for additional information about upgrading to the most recent version of LabVIEW for

Windows. Documentation for LabVIEW is available at /manuals.

l the LabVIEW FPGA Module.

Refer to the LabVIEW FPGA Module Release and Upgrade Notes for installation

instructions and information about getting started with the LabVIEW FPGA Module.

Documentation for the LabVIEW FPGA Module is available at /manuals.

3.

1

(Optional) Install the LabVIEW Real-Time Module.

The PXIe-5785 requires a chassis with slot cooling capacity ≥58 W. Not all chassis with slot

cooling capacity ≥58 W can achieve this ambient temperature range. Refer to the PXI Chassis

Manual for specifications to determine the ambient temperature ranges your chassis can achieve.

4 | | PXIe-5785 Getting Started Guide

Refer to the LabVIEW Real-Time Module Release and Upgrade Notes for system

requirements, installation instructions, and additional information about using the

LabVIEW Real-Time Module.

l FlexRIO.

Refer to the FlexRIO Readme for system requirements and installation instructions for

FlexRIO. Documentation for FlexRIO is available at /manuals.

Installing the PXIe-5785

Notice

To prevent damage to the PXIe-5785 caused by ESD or contamination,

1.

handle the module using the edges or the metal bracket.

Ensure the AC power source is connected to the chassis before installing the module.

The AC power cord grounds the chassis and protects it from electrical damage while you

install the module.

2.

3.

4.

5.

Power off the chassis.

Inspect the slot pins on the chassis backplane for any bends or damage prior to

installation. Do not install a module if the backplane is damaged.

Remove the black plastic covers from all the captive screws on the module front panel.

Identify a supported slot in the chassis. The following figure shows the symbols that

indicate the slot types.

Figure 1. Chassis Compatibility Symbols

1

23

4

5

Express System Controller Slot

Peripheral Slot

Express Hybrid Peripheral Slot

Express System Timing Slot

Express Peripheral Slot

PXIe-5785 modules can be placed in PXI Express peripheral slots, PXI Express hybrid

peripheral slots, or PXI Express system timing slots.

6.

7.

8.

Touch any metal part of the chassis to discharge static electricity.

Ensure that the ejector handle is in the downward (unlatched) position.

Place the module edges into the module guides at the top and bottom of the chassis. Slide

the module into the slot until it is fully inserted.

PXIe-5785 Getting Started Guide | © National Instruments | 5

Figure 2. Module Installation

1

0

2

3

s

re Module

r Handle in Downward (Unlatched) Position

the module in place by pulling up on the ejector handle.

Note

Tightening the top and bottom mounting screws increases mechanical

the module front panel to the chassis using the front-panel mounting screws.

stability and also electrically connects the front panel to the chassis, which can

improve the signal quality and electromagnetic performance.

all empty slots using EMC filler panels or fill using slot blockers to maximize

cooling air flow, depending on your application.

on the chassis.

PXIe-5785 Front Panel

The following figure shows the PXIe-5785 front panel.

6 | | PXIe-5785 Getting Started Guide

Figure 3. PXIe-5785 Front Panel

PXIe-5785

FlexRIO IF Transceiver

DIO

12-Bit, 6.4 GS/s

4 Vpp

MAX

AI 0

AI 1

AO 0

AO 1

4 Vpp

MAX

REF/

CLK IN

The following table describes the signal connections for the PXIe-5785.

ConnectorDescriptionFunction

DIO

Molex Nano-Pitch DIO

connector

Multi-signal DIO connector that provides

access to FPGA multi-gigabit transceivers

(MGTs) and general-purpose LVCMOS

signals.

Analog input 0:1Standard SMA female

connector

PXIe-5785 Getting Started Guide | © National Instruments | 7

ConnectorDescriptionFunction

AO 0:1

Standard SMA female

connector

Analog output connection.

Input for an external Reference Clock or

Sample Clock.

REF/CLK INStandard SMA female

connector

The following table lists the available pins on the DIO connector.

SignalTypeDirection

MGT Tx± <3..0>

2

MGT Rx± <3..0>

2

DIO <7..0>

5.0 V

GND

Xilinx UltraScale GTH

Xilinx UltraScale GTH

Single-ended

DC

Ground

Output

Input

Bidirectional

Output

Notice

The maximum input signal levels are valid only when the module is

powered on. To avoid permanent damage to the PXIe-5785, do not apply a signal to

the device when the module is powered down.

Notice

Connections that exceed any of the maximum ratings of any connector on

the PXIe-5785 can damage the device and the chassis. NI is not liable for any

damage resulting from such connections.

Configuring the PXIe-5785 in MAX

Use Measurement & Automation Explorer (MAX) to configure your NI hardware. MAX

informs other programs about which NI hardware products are in the system and how they are

configured. MAX is automatically installed with FlexRIO.

MAX.

the configuration tree, expand Devices and Interfaces to see the list of installed NI

hardware.

Installed modules appear under the name of their associated chassis.

your Chassis tree item.

2

MGTs are available only on devices with KU040 and KU060 FPGAs.

8 | | PXIe-5785 Getting Started Guide

MAX lists all modules installed in the chassis. Your default names may vary.

Note

If you do not see your module listed, press to refresh the list of

installed modules. If the module is still not listed, power off the system, ensure

the module is correctly installed, and restart.

4.

5.

Record the identifier MAX assigns to the hardware. Use this identifier when

programming the PXIe-5785.

Self-test the hardware by selecting the item in the configuration tree and clicking Self-

Test in the MAX toolbar.

The MAX self-test performs a basic verification of hardware resources.

FlexRIO Examples

FlexRIO includes several example applications for LabVIEW. These examples serve as

interactive tools, programming models, and as building blocks in your own applications.

Accessing FlexRIO Examples

FlexRIO examples are available in LabVIEW's NI Example Finder. Complete the following

steps to access the examples by task.

LabVIEW, click Help»Find Examples.

the NI Example Finder window that appears, click Hardware Input and Output»

FlexRIO.

The examples are sorted by task. Click on an example and refer to the Information

window for a description of the example. Refer the Requirements window for a list of

hardware devices that can run the example.

You can also click the Search tab to search all installed examples by keyword. For

example, search for

FlexRIO

to locate all FlexRIO examples.

Examples also are available online that demonstrate FlexRIO basics, such as using DRAM,

acquiring data from adapter modules, and performing high throughput streaming. Refer to

/examples for these examples and for more information.

Block Diagram

The following figure shows a block diagram of the carrier portion of the PXIe-5785 (KU035

FPGA option).

PXIe-5785 Getting Started Guide | © National Instruments | 9

Figure 4. Carrier Block Diagram (KU035)

Power Supplies

D

I

O

C

o

n

n

e

c

t

o

r

(

F

r

o

n

t

P

a

n

e

l

)

+5 V

+12 V

+12 V, +3.3 V

Gen3 x8 PCIe

DStarB, DStarC

PXI Triggers

GPIO

+1.8 V

+12 V

FPGA

Clk 100

Clk 10

MGTs

Module Clocking

Synchronization

A

d

a

p

t

e

r

M

o

d

u

l

e

C

o

n

n

e

c

t

o

r

Configuration, GPIO

Reference Clock

The following figure shows a block diagram of the carrier portion of the PXIe-5785 (KU040

and KU060 FPGA options).

Figure 5. Carrier Block Diagram (KU040 and KU060)

Power Supplies

D

I

O

C

o

n

n

e

c

t

o

r

(

F

r

o

n

t

P

a

n

e

l

)

+5 V

+12 V

+12V, +3.3 V

Flash

GPIO

MGTs

+1.8 V

+12 V

Gen3 x8 PCIe

DStarB, DStarC

FPGA

PXITriggers

Clk 100

Clk 10

A

d

a

p

t

e

r

M

o

d

u

l

e

C

o

n

n

e

c

t

o

r

Configuration, GPIO

MGTs

Module Clocking

Synchronization

DRAM Bank 0

(2 GB)

Reference Clock

DRAM Bank 1

(2 GB)

The following figure shows a block diagram of the I/O portion of the PXIe-5785.

10 | | PXIe-5785 Getting Started Guide

P

X

I

e

C

o

n

n

e

c

t

o

r

s

P

X

I

e

C

o

n

n

e

c

t

o

r

s

Flash

Figure 6. PXIe-5785 Block Diagram

ADC12DJ3200

Dual 12-bit, 3.2 GS/s

Single 12-bit, 6.4 GS/s

ANALOG INPUT

AI0 SMA

AC (Balun)

Coupled Path

AI1 SMA

AC (Balun)

Coupled Path

ANALOG OUTPUT

AO0 SMA

Optional

Anti-Image Filter

AC (Balun)

Coupled Path

Adapter Module

Connector

AO1 SMA

Optional

Anti-Image Filter

AC (Balun)

Coupled Path

CLOCKING

EXTERNAL REF/SCLK

CLK IN SMA

DAC38RF82

Dual 12-bit, 6.4 GS/s

Component-Level Intellectual Property (CLIP)

The LabVIEW FPGA Module includes component-level intellectual property (CLIP) for HDL

IP integration. FlexRIO devices support two types of CLIP: user-defined and socketed.

•User-defined CLIP allows you to insert HDL IP into an FPGA target, enabling VHDL

code to communicate directly with an FPGA VI.

•Socketed CLIP provides the same IP integration of the user-defined CLIP, but it also

allows the CLIP to communicate directly with circuitry external to the FPGA. Adapter

module socketed CLIP allows your IP to communicate directly with both the FPGA VI

and the external adapter module connector interface.

The PXIe-5785 ships with socketed CLIP items that add module I/O to the LabVIEW project.

PXIe-5785 Getting Started Guide | © National Instruments | 11

Making a Measurement

Making a Measurement with LabVIEW

1.

2.

3.

4.

Launch LabVIEW.

Select Help»Find Example.

Open the example VI that you want to use by selecting Hardware Input and Output»

FlexRIO.

Follow any setup, configuration, and execution instructions in the VI.

Troubleshooting

If an issue persists after you complete a troubleshooting procedure, contact NI technical

support or visit /support.

What Should I Do if the PXIe-5785 Doesn't Appear in

MAX?

1.

2.

3.

4.

In the MAX configuration tree, expand Devices and Interfaces.

Expand the Chassis tree to see the list of installed hardware, and press to refresh

the list.

If the module is still not listed, power off the system, ensure that all hardware is correctly

installed, and restart the system.

Navigate to the Device Manager.

Operating System

Windows 10/8.1

Windows 7

5.

Description

Right-click the Start button, and select Device Manager.

Select Start»Control Panel»Device Manager.

Verify the PXIe-5785 appears in the Device Manager.

a)Under an NI entry, confirm that a PXIe-5785 entry appears.

Note

If you are using a PC with a device for PXI remote control system,

b)

under System Devices, also confirm that no error conditions appear for the

PCI-to-PCI Bridge.

If error conditions appear, reinstall FlexRIO and the PXIe-5785.

What Should I Do if the PXIe-5785 Fails the Self-Test?

1.

2.

3.

4.

Restart the system.

Launch MAX, and perform the self-test again.

Power off the chassis.

Reinstall the failed module in a different slot.

12 | | PXIe-5785 Getting Started Guide

5.

6.

Power on the chassis.

Perform the self-test again.

Where to Go Next

Refer to the following figure for information about other product tasks and associated

resources for those tasks.

Located online at /manualsLocated using the NI Example Finder

EXPLORE

the application development

environment (ADE)

for your application.

LEARN

about hardware features

or review device

specifications.

CREATE

custom applications with

an application programming

interface (API).

Learn LabVIEW Basics

LabVIEW FPGA

Module Help

PXIe-5785

Specifications*

FlexRIO Module

Examples*

FlexRIO Help*

DISCOVER

more about your products through .

Support

/support

FlexRIO

/flexrio

Services

/services

NI Community

/community

*This item is also installed with the driver software.

Worldwide Support and Services

The NI website is your complete resource for technical support. At /support, you have

access to everything from troubleshooting and application development self-help resources to

email and phone assistance from NI Application Engineers.

Visit /services for information about the services NI offers.

Visit /register to register your NI product. Product registration facilitates technical

support and ensures that you receive important information updates from NI.

NI corporate headquarters is located at 11500 North Mopac Expressway, Austin, Texas,

78759-3504. NI also has offices located around the world. For support in the United States,

create your service request at /support or dial 1 866 ASK MYNI (275 6964). For

PXIe-5785 Getting Started Guide | © National Instruments | 13

support outside the United States, visit the Worldwide Offices section of /niglobal to

access the branch office websites, which provide up-to-date contact information.

Information is subject to change without notice. Refer to the NI Trademarks and Logo Guidelines at

/trademarks

for

information on NI trademarks. Other product and company names mentioned herein are trademarks or trade names of their

respective companies. For patents covering NI products/technology, refer to the appropriate location: Help»Patents in your

software, the

file on your media, or the National Instruments Patent Notice at

/patents

. You can find

information about end-user license agreements (EULAs) and third-party legal notices in the readme file for your NI product. Refer

to the Export Compliance Information at

/legal/export-compliance

for the NI global trade compliance policy and how

to obtain relevant HTS codes, ECCNs, and other import/export data. NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS

TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS. U.S.

Government Customers: The data contained in this manual was developed at private expense and is subject to the applicable

limited rights and restricted data rights as set forth in FAR 52.227-14, DFAR 252.227-7014, and DFAR 252.227-7015.

© 2018—2019 National Instruments. All rights reserved.

376897B-01March 21, 2019

发布评论

评论列表 (0)

  1. 暂无评论