最新消息: USBMI致力于为网友们分享Windows、安卓、IOS等主流手机系统相关的资讯以及评测、同时提供相关教程、应用、软件下载等服务。

SmartOnline 3000VA 3kVA 2.5kW 双转换无间断电源说明书

IT圈 admin 38浏览 0评论

2024年8月28日发(作者:种阳曦)

SmartOnline 100-127V 3kVA 2.5kW On-Line

Double-Conversion UPS, Extended Run, SNMP,

Webcard, 2U Rack/Tower, USB, DB9 Serial

MODEL NUMBER: SU3000RTXL2U

Highlights

3000VA / 3kVA / 2500 watt

on-line double-conversion 2U

rack/tower UPS

100/110/115/120/127V 50/60Hz

output, high efficiency economy

mode option

Expandable runtime, Hot-swap

batteries, 26 in / 66 cm installed

depth

USB, RS232 & EPO ports;

support for SNMP/WEB card

options

Front panel status LEDs with

detailed load and battery metering

2 independently switchable

output load banks

NEMA L5-30P input; L5-30R &

5-15/20R outlets

Description

3000VA / 3kVA / 2500 watt on-line, double-conversion UPS system for critical server, network and

telecommunications equipment. 2U rackmount form factor with an installed depth of only 26 inches (66cm).

Expandable battery runtime with optional BP72V15-2U (limit 1), BP72V28RT-3U (multi-pack compatible) and

BP72V18-2US (multi-pack compatible) external battery packs. Full time sine wave 100/110/115/120/127V output

with +/-2% voltage regulation. Uninterruptible Power Supply (UPS) actively converts raw incoming AC power to

DC, then re-converts output back to completely regulated, filtered AC output. Operates continuously without

using battery power during brownouts to 70V and overvoltages to 144V. Up to 97% efficiency in optional

economy mode saves BTU heat output and energy costs. NEMA L5-30P input plug. NEMA L5-30R, NEMA

5-15/20R and NEMA 5-15R output receptacles. Network-grade AC surge and noise suppression. Zero transfer

time between AC and battery operation. Network management interfaces include USB port, DB9 serial port and

SNMPWEBCARD slot. Built-in DB9 port offers both enhanced RS-232 enabled monitoring data, plus contact

closure monitoring ability. HID-compliant USB interface enables integration with built-in power management and

auto shutdown features of Windows and Mac OS X. Supports simultaneous detailed monitoring of equipment

load levels, self-test data and mains power conditions via all network interfaces. Includes PowerAlert monitoring

software and complete cabling. Emergency Power Off (EPO) interface. Integrated two bank PDU switching

Applications

Distributed Server Rooms

Network Closets

Small Business Networks

Voice over IP (VoIP) Phone

Systems

Package Includes

SU3000RTXL2U UPS System

4 post rackmount installation

brackets

PowerAlert Software CD and

cabling

Owner's manual with warranty

information

supports automated load shedding and remote-reboot of connected equipment. Multi-stage metered current monitoring and battery charge status LEDs.

Mains power and voltage regulation LEDs. Audible Alarm. Self-test. Fault-tolerant auto-bypass mode. LED display panel easily rotates for better viewing in

rackmount or tower configurations. Includes 4 post rackmount accessories. 2-9USTAND tower kit and 2POSTRMKITWM two post rackmount hardware

accessories available. Field replaceable, hot swappable internal batteries and external battery packs. $250,000 Ultimate Lifetime Insurance (U.S., Canada,

and Puerto Rico only).

Features

SmartOnline high-performance UPS system is ideal for critical voice, data, medical and industrial network applications

Optional economy-mode operation with 97% efficiency for reduced power consumption and cooler operation

1 / 6

Economy mode is schedulable via PowerAlert UPS management software for daily or weekly hours of operation to enable precision output during peak

operating hours and high efficiency, low BTU emission operation during off-peak times

Maintains continuous operation through blackouts, voltage fluctuations and surges

On-line, double-conversion mode provides perfectly regulated sine wave output within 2% of 100/110/115/120/127V (user selectable) with zero transfer

time

Supports operation at 50/60Hz (auto-sensing) with the ability for full-time frequency conversion from 50 to 60Hz or 60 to 50Hz (frequency conversion

de-rates UPS capacity by 20%)

Removes harmonic distortion, fast electrical impulses, frequency variations and other hard to solve power problems not addressed by other UPS types

Corrects line voltage conditions as low as 70V and as high as 144V to within 2% of selected nominal voltage

Standard internal battery set offers 15 minutes runtime at half load (1250W) and 6 minutes at full load (2500W)

Expandable battery runtime with optional BP72V15-2U (limit 1), BP72V28RT-3U (multi-pack compatible) and BP72V18-2US (multi-pack compatible)

external battery packs

Compact rackmount form factor installs using only 2 rack spaces (2U) with a depth of only 26 inches

Ships with all mounting accessories for 4 post rackmount installation

Optional 2POSTRMKITWM enables 2 post rackmount installation

Optional 2-9USTAND accessory enables upright tower placement

Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions

Network interfaces support simultaneous communications via built-in USB, DB9 serial / contact-closure and SNMPWEBCARD slot

HID compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Included

PowerAlert UPS monitoring software supports safe unattended shutdown, monitoring and control via local connected servers, plus any number of

additional servers over IP

UPS interface supports on-battery, low-battery, power-restored, AC-voltage, DC-voltage, output current monitoring, battery charge current, battery

capacity, AC line frequency, timed inverter shutoff, activate self-test, load bank output power control and remote reboot, UPS nominal voltage adjustment

and UPS line to battery power voltage setpoints

Built-in Emergency Power Off (EPO) interface with cable

NEMA L5-30P input plug / NEMA 5-15/20R & L5-30R output receptacles

Integrated 2 bank switched PDU enables remote outlet management for load shedding or remote reboot of individual load banks (each bank has 3 outlets)

Front panel LEDs offer current monitoring and battery charge level information

Network grade AC surge suppression

Field replaceable, hot swappable internal batteries and external battery packs

$250,000 Ultimate Lifetime Insurance (U.S., Canada, and Puerto Rico only)

Specifications

OUTPUT

Output Capacity Details

Output Volt Amp Capacity (VA)

Output kVA Capacity (kVA)

Output Watt Capacity (Watts)

Output kW Capacity (kW)

Power Factor

Max output is 3000VA 2400W at 100V, 110V, 115V nominal settings

3000

3

2500

2.5

0.83

2 / 6

Crest Factor

Nominal Output Voltage(s)

Supported

Nominal Voltage Details

Frequency Compatibility

Frequency Compatibility Details

Output Voltage Regulation (Line

Mode)

Output Voltage Regulation

(Economy Line Mode)

Output Voltage Regulation (Battery

Mode)

Output Receptacles

Load Management Receptacles

Output Circuit Breakers

Output AC Waveform (AC Mode)

Output AC Waveform (Battery Mode)

3:1

100V; 110V; 115V; 120V; 127V

120V default

50 / 60 Hz

Output frequency matches input nominal on startup, defaults to 60 Hz on cold-start. Frequency conversion from 60

to 50 Hz -or- 50 to 60 Hz supported. Output capacity de-rates by 25% during frequency conversion operation.

+/- 2%

-12%, + 10%

+/- 2%

(6) 5-15/20R; (1) L5-30R

Two switchable three-outlet load banks

20A (x2) - each breaker protects 3 5-15/20R outlets, L5-30R outlet is un-breakered

Pure Sine wave

Pure Sine wave

INPUT

Rated input current (Maximum Load)

Nominal Input Voltage(s) Supported

UPS Input Connection Type

Recommended Electrical Service

Input Cord Length (ft.)

Input Cord Length (m)

Input Phase

24A

100V AC; 110V AC; 115V AC; 120V AC; 127V AC

L5-30P

30A 120V

10

3

Single-Phase

BATTERY

Full Load Runtime (min.)

Half Load Runtime (min.)

Expandable Battery Runtime

External Battery Pack Compatibility

DC System Voltage (VDC)

Battery Recharge Rate (Included

Batteries)

Internal UPS Replacement Battery

Cartridge

Battery Access

6 min. (2500w)

15 min. (1250w)

Supports extended runtime with optional external battery packs

BP72V15-2U (limit 1); BP72V28RT-3U (multi-pack compatible); BP72V18-2US (multi-pack compatible)

72

Less than 4.8 hours from 10% to 90% (typical, full load discharge)

RBC96-2U

Front panel battery access door

3 / 6

Battery Replacement DescriptionHot-swappable, user replaceable batteries

VOLTAGE REGULATION

Voltage Regulation Description

Overvoltage Correction

Undervoltage Correction

Severe Undervoltage Correction

Online, double-conversion power conditioning

2% output voltage regulation during overvoltages to 144

2% output voltage regulation during undervoltages to 80

2% output voltage regulation during undervoltages to 70V (under 66% load only) or 60V (under 33% load only)

LEDS ALARMS & SWITCHES

LED Indicators

Audible Alarm

Alarm Cancel Operation

Switches

14 LEDs indicate line power, online mode, economy/bypass mode, on-battery, overload, battery low, replace battery

and fault status information; 4-LED meter displays load and battery charge levels; LED panel rotates for viewing in

rack/tower formats

Audible alarm indicates power failure, low battery, overload, replace battery and EPO operation

Power-fail alarm can be silenced using alarm-cancel switch

2 Switches control off/on power status and alarm-cancel/self-test operation

SURGE / NOISE SUPPRESSION

UPS AC Suppression Joule Rating

EMI / RFI AC Noise Suppression

AC Suppression Response Time

504 joules

Yes

Instantaneous

PHYSICAL

Included Mounting Accessory

Description

Installation Form Factors Supported

with Optional Accessories

Primary Form Factor

UPS Power Module Dimensions

(hwd, in.)

UPS Power Module Dimensions

(hwd, cm)

Rack Height (U Spaces)

UPS Power Module Weight (lbs.)

UPS Power Module Weight (kg)

UPS Shipping Dimensions (hwd / in.)

UPS Shipping Dimensions (hwd /

cm)

Shipping Weight (lbs.)

Shipping Weight (kg)

Cooling Method

Includes 4 post rackmount installation accessories

2 post rackmount (2POSTRMKITWM); Tower (2-9USTAND)

Rackmount

3.5 x 17.3 x 26

8.9 x 43.9 x 66

2

68.8

31.2

9 x 22 x 32.8

22.9 x 55.9 x 83.3

78.3

35.5

Fan

4 / 6

UPS Housing MaterialSteel

ENVIRONMENTAL

Operating Temperature Range

Storage Temperature Range

Relative Humidity

AC Mode BTU / Hr. (Full Load)

AC Economy Mode BTU / Hr. (Full

Load)

Battery Mode BTU / Hr. (Full Load)

AC Mode Efficiency Rating (100%

Load)

AC Economy Mode Efficiency Rating

(100% Load)

+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius.

+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius.

0 to 95%, non-condensing

1000

241

1500

89%

97%

COMMUNICATIONS

Communications Interface

Network Monitoring Port Description

PowerAlert Software

Communications Cable

WatchDog Compatibility

USB (HID enabled); DB9 Serial; Contact closure; EPO (emergency power off); Slot for SNMP/Web interface

Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 and contact closure

communications

Included

USB and DB9 cabling included

Supports Watchdog application, OS and hard-reboot restart options for remote applications

LINE / BATTERY TRANSFER

Transfer Time

Low Voltage Transfer to Battery

Power (Setpoint)

High Voltage Transfer to Battery

Power (Setpoint)

No transfer time (0 ms.) in online, double-conversion mode

80V (100% load), 70V (66% load), 60V (33% load)

144

SPECIAL FEATURES

Cold Start (Startup in Battery Mode

During a Power Failure)

High Availability UPS Features

Green Energy-Saving Features

Cold-start operation supported

Automatic inverter bypass; Hot swappable batteries

High efficiency economy mode operation; Individually controllable load banks; Schedulable daily hours of economy

mode operation

CERTIFICATIONS

UPS CertificationsTested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI)

WARRANTY

5 / 6

Product Warranty Period (Worldwide)

Connected Equipment Insurance

(U.S., Canada & Puerto Rico)

2-year limited warranty

$250,000 Ultimate Lifetime Insurance

© 2015 Tripp Lite. All rights reserved. All trademarks are the sole property of their respective owners. Tripp Lite has a policy of continuous improvement.

Specifications are subject to change without notice. Photos may differ slightly from final products.

6 / 6

2024年8月28日发(作者:种阳曦)

SmartOnline 100-127V 3kVA 2.5kW On-Line

Double-Conversion UPS, Extended Run, SNMP,

Webcard, 2U Rack/Tower, USB, DB9 Serial

MODEL NUMBER: SU3000RTXL2U

Highlights

3000VA / 3kVA / 2500 watt

on-line double-conversion 2U

rack/tower UPS

100/110/115/120/127V 50/60Hz

output, high efficiency economy

mode option

Expandable runtime, Hot-swap

batteries, 26 in / 66 cm installed

depth

USB, RS232 & EPO ports;

support for SNMP/WEB card

options

Front panel status LEDs with

detailed load and battery metering

2 independently switchable

output load banks

NEMA L5-30P input; L5-30R &

5-15/20R outlets

Description

3000VA / 3kVA / 2500 watt on-line, double-conversion UPS system for critical server, network and

telecommunications equipment. 2U rackmount form factor with an installed depth of only 26 inches (66cm).

Expandable battery runtime with optional BP72V15-2U (limit 1), BP72V28RT-3U (multi-pack compatible) and

BP72V18-2US (multi-pack compatible) external battery packs. Full time sine wave 100/110/115/120/127V output

with +/-2% voltage regulation. Uninterruptible Power Supply (UPS) actively converts raw incoming AC power to

DC, then re-converts output back to completely regulated, filtered AC output. Operates continuously without

using battery power during brownouts to 70V and overvoltages to 144V. Up to 97% efficiency in optional

economy mode saves BTU heat output and energy costs. NEMA L5-30P input plug. NEMA L5-30R, NEMA

5-15/20R and NEMA 5-15R output receptacles. Network-grade AC surge and noise suppression. Zero transfer

time between AC and battery operation. Network management interfaces include USB port, DB9 serial port and

SNMPWEBCARD slot. Built-in DB9 port offers both enhanced RS-232 enabled monitoring data, plus contact

closure monitoring ability. HID-compliant USB interface enables integration with built-in power management and

auto shutdown features of Windows and Mac OS X. Supports simultaneous detailed monitoring of equipment

load levels, self-test data and mains power conditions via all network interfaces. Includes PowerAlert monitoring

software and complete cabling. Emergency Power Off (EPO) interface. Integrated two bank PDU switching

Applications

Distributed Server Rooms

Network Closets

Small Business Networks

Voice over IP (VoIP) Phone

Systems

Package Includes

SU3000RTXL2U UPS System

4 post rackmount installation

brackets

PowerAlert Software CD and

cabling

Owner's manual with warranty

information

supports automated load shedding and remote-reboot of connected equipment. Multi-stage metered current monitoring and battery charge status LEDs.

Mains power and voltage regulation LEDs. Audible Alarm. Self-test. Fault-tolerant auto-bypass mode. LED display panel easily rotates for better viewing in

rackmount or tower configurations. Includes 4 post rackmount accessories. 2-9USTAND tower kit and 2POSTRMKITWM two post rackmount hardware

accessories available. Field replaceable, hot swappable internal batteries and external battery packs. $250,000 Ultimate Lifetime Insurance (U.S., Canada,

and Puerto Rico only).

Features

SmartOnline high-performance UPS system is ideal for critical voice, data, medical and industrial network applications

Optional economy-mode operation with 97% efficiency for reduced power consumption and cooler operation

1 / 6

Economy mode is schedulable via PowerAlert UPS management software for daily or weekly hours of operation to enable precision output during peak

operating hours and high efficiency, low BTU emission operation during off-peak times

Maintains continuous operation through blackouts, voltage fluctuations and surges

On-line, double-conversion mode provides perfectly regulated sine wave output within 2% of 100/110/115/120/127V (user selectable) with zero transfer

time

Supports operation at 50/60Hz (auto-sensing) with the ability for full-time frequency conversion from 50 to 60Hz or 60 to 50Hz (frequency conversion

de-rates UPS capacity by 20%)

Removes harmonic distortion, fast electrical impulses, frequency variations and other hard to solve power problems not addressed by other UPS types

Corrects line voltage conditions as low as 70V and as high as 144V to within 2% of selected nominal voltage

Standard internal battery set offers 15 minutes runtime at half load (1250W) and 6 minutes at full load (2500W)

Expandable battery runtime with optional BP72V15-2U (limit 1), BP72V28RT-3U (multi-pack compatible) and BP72V18-2US (multi-pack compatible)

external battery packs

Compact rackmount form factor installs using only 2 rack spaces (2U) with a depth of only 26 inches

Ships with all mounting accessories for 4 post rackmount installation

Optional 2POSTRMKITWM enables 2 post rackmount installation

Optional 2-9USTAND accessory enables upright tower placement

Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions

Network interfaces support simultaneous communications via built-in USB, DB9 serial / contact-closure and SNMPWEBCARD slot

HID compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Included

PowerAlert UPS monitoring software supports safe unattended shutdown, monitoring and control via local connected servers, plus any number of

additional servers over IP

UPS interface supports on-battery, low-battery, power-restored, AC-voltage, DC-voltage, output current monitoring, battery charge current, battery

capacity, AC line frequency, timed inverter shutoff, activate self-test, load bank output power control and remote reboot, UPS nominal voltage adjustment

and UPS line to battery power voltage setpoints

Built-in Emergency Power Off (EPO) interface with cable

NEMA L5-30P input plug / NEMA 5-15/20R & L5-30R output receptacles

Integrated 2 bank switched PDU enables remote outlet management for load shedding or remote reboot of individual load banks (each bank has 3 outlets)

Front panel LEDs offer current monitoring and battery charge level information

Network grade AC surge suppression

Field replaceable, hot swappable internal batteries and external battery packs

$250,000 Ultimate Lifetime Insurance (U.S., Canada, and Puerto Rico only)

Specifications

OUTPUT

Output Capacity Details

Output Volt Amp Capacity (VA)

Output kVA Capacity (kVA)

Output Watt Capacity (Watts)

Output kW Capacity (kW)

Power Factor

Max output is 3000VA 2400W at 100V, 110V, 115V nominal settings

3000

3

2500

2.5

0.83

2 / 6

Crest Factor

Nominal Output Voltage(s)

Supported

Nominal Voltage Details

Frequency Compatibility

Frequency Compatibility Details

Output Voltage Regulation (Line

Mode)

Output Voltage Regulation

(Economy Line Mode)

Output Voltage Regulation (Battery

Mode)

Output Receptacles

Load Management Receptacles

Output Circuit Breakers

Output AC Waveform (AC Mode)

Output AC Waveform (Battery Mode)

3:1

100V; 110V; 115V; 120V; 127V

120V default

50 / 60 Hz

Output frequency matches input nominal on startup, defaults to 60 Hz on cold-start. Frequency conversion from 60

to 50 Hz -or- 50 to 60 Hz supported. Output capacity de-rates by 25% during frequency conversion operation.

+/- 2%

-12%, + 10%

+/- 2%

(6) 5-15/20R; (1) L5-30R

Two switchable three-outlet load banks

20A (x2) - each breaker protects 3 5-15/20R outlets, L5-30R outlet is un-breakered

Pure Sine wave

Pure Sine wave

INPUT

Rated input current (Maximum Load)

Nominal Input Voltage(s) Supported

UPS Input Connection Type

Recommended Electrical Service

Input Cord Length (ft.)

Input Cord Length (m)

Input Phase

24A

100V AC; 110V AC; 115V AC; 120V AC; 127V AC

L5-30P

30A 120V

10

3

Single-Phase

BATTERY

Full Load Runtime (min.)

Half Load Runtime (min.)

Expandable Battery Runtime

External Battery Pack Compatibility

DC System Voltage (VDC)

Battery Recharge Rate (Included

Batteries)

Internal UPS Replacement Battery

Cartridge

Battery Access

6 min. (2500w)

15 min. (1250w)

Supports extended runtime with optional external battery packs

BP72V15-2U (limit 1); BP72V28RT-3U (multi-pack compatible); BP72V18-2US (multi-pack compatible)

72

Less than 4.8 hours from 10% to 90% (typical, full load discharge)

RBC96-2U

Front panel battery access door

3 / 6

Battery Replacement DescriptionHot-swappable, user replaceable batteries

VOLTAGE REGULATION

Voltage Regulation Description

Overvoltage Correction

Undervoltage Correction

Severe Undervoltage Correction

Online, double-conversion power conditioning

2% output voltage regulation during overvoltages to 144

2% output voltage regulation during undervoltages to 80

2% output voltage regulation during undervoltages to 70V (under 66% load only) or 60V (under 33% load only)

LEDS ALARMS & SWITCHES

LED Indicators

Audible Alarm

Alarm Cancel Operation

Switches

14 LEDs indicate line power, online mode, economy/bypass mode, on-battery, overload, battery low, replace battery

and fault status information; 4-LED meter displays load and battery charge levels; LED panel rotates for viewing in

rack/tower formats

Audible alarm indicates power failure, low battery, overload, replace battery and EPO operation

Power-fail alarm can be silenced using alarm-cancel switch

2 Switches control off/on power status and alarm-cancel/self-test operation

SURGE / NOISE SUPPRESSION

UPS AC Suppression Joule Rating

EMI / RFI AC Noise Suppression

AC Suppression Response Time

504 joules

Yes

Instantaneous

PHYSICAL

Included Mounting Accessory

Description

Installation Form Factors Supported

with Optional Accessories

Primary Form Factor

UPS Power Module Dimensions

(hwd, in.)

UPS Power Module Dimensions

(hwd, cm)

Rack Height (U Spaces)

UPS Power Module Weight (lbs.)

UPS Power Module Weight (kg)

UPS Shipping Dimensions (hwd / in.)

UPS Shipping Dimensions (hwd /

cm)

Shipping Weight (lbs.)

Shipping Weight (kg)

Cooling Method

Includes 4 post rackmount installation accessories

2 post rackmount (2POSTRMKITWM); Tower (2-9USTAND)

Rackmount

3.5 x 17.3 x 26

8.9 x 43.9 x 66

2

68.8

31.2

9 x 22 x 32.8

22.9 x 55.9 x 83.3

78.3

35.5

Fan

4 / 6

UPS Housing MaterialSteel

ENVIRONMENTAL

Operating Temperature Range

Storage Temperature Range

Relative Humidity

AC Mode BTU / Hr. (Full Load)

AC Economy Mode BTU / Hr. (Full

Load)

Battery Mode BTU / Hr. (Full Load)

AC Mode Efficiency Rating (100%

Load)

AC Economy Mode Efficiency Rating

(100% Load)

+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius.

+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius.

0 to 95%, non-condensing

1000

241

1500

89%

97%

COMMUNICATIONS

Communications Interface

Network Monitoring Port Description

PowerAlert Software

Communications Cable

WatchDog Compatibility

USB (HID enabled); DB9 Serial; Contact closure; EPO (emergency power off); Slot for SNMP/Web interface

Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 and contact closure

communications

Included

USB and DB9 cabling included

Supports Watchdog application, OS and hard-reboot restart options for remote applications

LINE / BATTERY TRANSFER

Transfer Time

Low Voltage Transfer to Battery

Power (Setpoint)

High Voltage Transfer to Battery

Power (Setpoint)

No transfer time (0 ms.) in online, double-conversion mode

80V (100% load), 70V (66% load), 60V (33% load)

144

SPECIAL FEATURES

Cold Start (Startup in Battery Mode

During a Power Failure)

High Availability UPS Features

Green Energy-Saving Features

Cold-start operation supported

Automatic inverter bypass; Hot swappable batteries

High efficiency economy mode operation; Individually controllable load banks; Schedulable daily hours of economy

mode operation

CERTIFICATIONS

UPS CertificationsTested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI)

WARRANTY

5 / 6

Product Warranty Period (Worldwide)

Connected Equipment Insurance

(U.S., Canada & Puerto Rico)

2-year limited warranty

$250,000 Ultimate Lifetime Insurance

© 2015 Tripp Lite. All rights reserved. All trademarks are the sole property of their respective owners. Tripp Lite has a policy of continuous improvement.

Specifications are subject to change without notice. Photos may differ slightly from final products.

6 / 6

发布评论