2024年8月28日发(作者:种阳曦)
SmartOnline 100-127V 3kVA 2.5kW On-Line
Double-Conversion UPS, Extended Run, SNMP,
Webcard, 2U Rack/Tower, USB, DB9 Serial
MODEL NUMBER: SU3000RTXL2U
Highlights
3000VA / 3kVA / 2500 watt
on-line double-conversion 2U
rack/tower UPS
100/110/115/120/127V 50/60Hz
output, high efficiency economy
mode option
Expandable runtime, Hot-swap
batteries, 26 in / 66 cm installed
depth
USB, RS232 & EPO ports;
support for SNMP/WEB card
options
Front panel status LEDs with
detailed load and battery metering
2 independently switchable
output load banks
NEMA L5-30P input; L5-30R &
5-15/20R outlets
Description
3000VA / 3kVA / 2500 watt on-line, double-conversion UPS system for critical server, network and
telecommunications equipment. 2U rackmount form factor with an installed depth of only 26 inches (66cm).
Expandable battery runtime with optional BP72V15-2U (limit 1), BP72V28RT-3U (multi-pack compatible) and
BP72V18-2US (multi-pack compatible) external battery packs. Full time sine wave 100/110/115/120/127V output
with +/-2% voltage regulation. Uninterruptible Power Supply (UPS) actively converts raw incoming AC power to
DC, then re-converts output back to completely regulated, filtered AC output. Operates continuously without
using battery power during brownouts to 70V and overvoltages to 144V. Up to 97% efficiency in optional
economy mode saves BTU heat output and energy costs. NEMA L5-30P input plug. NEMA L5-30R, NEMA
5-15/20R and NEMA 5-15R output receptacles. Network-grade AC surge and noise suppression. Zero transfer
time between AC and battery operation. Network management interfaces include USB port, DB9 serial port and
SNMPWEBCARD slot. Built-in DB9 port offers both enhanced RS-232 enabled monitoring data, plus contact
closure monitoring ability. HID-compliant USB interface enables integration with built-in power management and
auto shutdown features of Windows and Mac OS X. Supports simultaneous detailed monitoring of equipment
load levels, self-test data and mains power conditions via all network interfaces. Includes PowerAlert monitoring
software and complete cabling. Emergency Power Off (EPO) interface. Integrated two bank PDU switching
Applications
Distributed Server Rooms
Network Closets
Small Business Networks
Voice over IP (VoIP) Phone
Systems
Package Includes
SU3000RTXL2U UPS System
4 post rackmount installation
brackets
PowerAlert Software CD and
cabling
Owner's manual with warranty
information
supports automated load shedding and remote-reboot of connected equipment. Multi-stage metered current monitoring and battery charge status LEDs.
Mains power and voltage regulation LEDs. Audible Alarm. Self-test. Fault-tolerant auto-bypass mode. LED display panel easily rotates for better viewing in
rackmount or tower configurations. Includes 4 post rackmount accessories. 2-9USTAND tower kit and 2POSTRMKITWM two post rackmount hardware
accessories available. Field replaceable, hot swappable internal batteries and external battery packs. $250,000 Ultimate Lifetime Insurance (U.S., Canada,
and Puerto Rico only).
Features
SmartOnline high-performance UPS system is ideal for critical voice, data, medical and industrial network applications
Optional economy-mode operation with 97% efficiency for reduced power consumption and cooler operation
1 / 6
Economy mode is schedulable via PowerAlert UPS management software for daily or weekly hours of operation to enable precision output during peak
operating hours and high efficiency, low BTU emission operation during off-peak times
Maintains continuous operation through blackouts, voltage fluctuations and surges
On-line, double-conversion mode provides perfectly regulated sine wave output within 2% of 100/110/115/120/127V (user selectable) with zero transfer
time
Supports operation at 50/60Hz (auto-sensing) with the ability for full-time frequency conversion from 50 to 60Hz or 60 to 50Hz (frequency conversion
de-rates UPS capacity by 20%)
Removes harmonic distortion, fast electrical impulses, frequency variations and other hard to solve power problems not addressed by other UPS types
Corrects line voltage conditions as low as 70V and as high as 144V to within 2% of selected nominal voltage
Standard internal battery set offers 15 minutes runtime at half load (1250W) and 6 minutes at full load (2500W)
Expandable battery runtime with optional BP72V15-2U (limit 1), BP72V28RT-3U (multi-pack compatible) and BP72V18-2US (multi-pack compatible)
external battery packs
Compact rackmount form factor installs using only 2 rack spaces (2U) with a depth of only 26 inches
Ships with all mounting accessories for 4 post rackmount installation
Optional 2POSTRMKITWM enables 2 post rackmount installation
Optional 2-9USTAND accessory enables upright tower placement
Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions
Network interfaces support simultaneous communications via built-in USB, DB9 serial / contact-closure and SNMPWEBCARD slot
HID compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Included
PowerAlert UPS monitoring software supports safe unattended shutdown, monitoring and control via local connected servers, plus any number of
additional servers over IP
UPS interface supports on-battery, low-battery, power-restored, AC-voltage, DC-voltage, output current monitoring, battery charge current, battery
capacity, AC line frequency, timed inverter shutoff, activate self-test, load bank output power control and remote reboot, UPS nominal voltage adjustment
and UPS line to battery power voltage setpoints
Built-in Emergency Power Off (EPO) interface with cable
NEMA L5-30P input plug / NEMA 5-15/20R & L5-30R output receptacles
Integrated 2 bank switched PDU enables remote outlet management for load shedding or remote reboot of individual load banks (each bank has 3 outlets)
Front panel LEDs offer current monitoring and battery charge level information
Network grade AC surge suppression
Field replaceable, hot swappable internal batteries and external battery packs
$250,000 Ultimate Lifetime Insurance (U.S., Canada, and Puerto Rico only)
Specifications
OUTPUT
Output Capacity Details
Output Volt Amp Capacity (VA)
Output kVA Capacity (kVA)
Output Watt Capacity (Watts)
Output kW Capacity (kW)
Power Factor
Max output is 3000VA 2400W at 100V, 110V, 115V nominal settings
3000
3
2500
2.5
0.83
2 / 6
Crest Factor
Nominal Output Voltage(s)
Supported
Nominal Voltage Details
Frequency Compatibility
Frequency Compatibility Details
Output Voltage Regulation (Line
Mode)
Output Voltage Regulation
(Economy Line Mode)
Output Voltage Regulation (Battery
Mode)
Output Receptacles
Load Management Receptacles
Output Circuit Breakers
Output AC Waveform (AC Mode)
Output AC Waveform (Battery Mode)
3:1
100V; 110V; 115V; 120V; 127V
120V default
50 / 60 Hz
Output frequency matches input nominal on startup, defaults to 60 Hz on cold-start. Frequency conversion from 60
to 50 Hz -or- 50 to 60 Hz supported. Output capacity de-rates by 25% during frequency conversion operation.
+/- 2%
-12%, + 10%
+/- 2%
(6) 5-15/20R; (1) L5-30R
Two switchable three-outlet load banks
20A (x2) - each breaker protects 3 5-15/20R outlets, L5-30R outlet is un-breakered
Pure Sine wave
Pure Sine wave
INPUT
Rated input current (Maximum Load)
Nominal Input Voltage(s) Supported
UPS Input Connection Type
Recommended Electrical Service
Input Cord Length (ft.)
Input Cord Length (m)
Input Phase
24A
100V AC; 110V AC; 115V AC; 120V AC; 127V AC
L5-30P
30A 120V
10
3
Single-Phase
BATTERY
Full Load Runtime (min.)
Half Load Runtime (min.)
Expandable Battery Runtime
External Battery Pack Compatibility
DC System Voltage (VDC)
Battery Recharge Rate (Included
Batteries)
Internal UPS Replacement Battery
Cartridge
Battery Access
6 min. (2500w)
15 min. (1250w)
Supports extended runtime with optional external battery packs
BP72V15-2U (limit 1); BP72V28RT-3U (multi-pack compatible); BP72V18-2US (multi-pack compatible)
72
Less than 4.8 hours from 10% to 90% (typical, full load discharge)
RBC96-2U
Front panel battery access door
3 / 6
Battery Replacement DescriptionHot-swappable, user replaceable batteries
VOLTAGE REGULATION
Voltage Regulation Description
Overvoltage Correction
Undervoltage Correction
Severe Undervoltage Correction
Online, double-conversion power conditioning
2% output voltage regulation during overvoltages to 144
2% output voltage regulation during undervoltages to 80
2% output voltage regulation during undervoltages to 70V (under 66% load only) or 60V (under 33% load only)
LEDS ALARMS & SWITCHES
LED Indicators
Audible Alarm
Alarm Cancel Operation
Switches
14 LEDs indicate line power, online mode, economy/bypass mode, on-battery, overload, battery low, replace battery
and fault status information; 4-LED meter displays load and battery charge levels; LED panel rotates for viewing in
rack/tower formats
Audible alarm indicates power failure, low battery, overload, replace battery and EPO operation
Power-fail alarm can be silenced using alarm-cancel switch
2 Switches control off/on power status and alarm-cancel/self-test operation
SURGE / NOISE SUPPRESSION
UPS AC Suppression Joule Rating
EMI / RFI AC Noise Suppression
AC Suppression Response Time
504 joules
Yes
Instantaneous
PHYSICAL
Included Mounting Accessory
Description
Installation Form Factors Supported
with Optional Accessories
Primary Form Factor
UPS Power Module Dimensions
(hwd, in.)
UPS Power Module Dimensions
(hwd, cm)
Rack Height (U Spaces)
UPS Power Module Weight (lbs.)
UPS Power Module Weight (kg)
UPS Shipping Dimensions (hwd / in.)
UPS Shipping Dimensions (hwd /
cm)
Shipping Weight (lbs.)
Shipping Weight (kg)
Cooling Method
Includes 4 post rackmount installation accessories
2 post rackmount (2POSTRMKITWM); Tower (2-9USTAND)
Rackmount
3.5 x 17.3 x 26
8.9 x 43.9 x 66
2
68.8
31.2
9 x 22 x 32.8
22.9 x 55.9 x 83.3
78.3
35.5
Fan
4 / 6
UPS Housing MaterialSteel
ENVIRONMENTAL
Operating Temperature Range
Storage Temperature Range
Relative Humidity
AC Mode BTU / Hr. (Full Load)
AC Economy Mode BTU / Hr. (Full
Load)
Battery Mode BTU / Hr. (Full Load)
AC Mode Efficiency Rating (100%
Load)
AC Economy Mode Efficiency Rating
(100% Load)
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius.
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius.
0 to 95%, non-condensing
1000
241
1500
89%
97%
COMMUNICATIONS
Communications Interface
Network Monitoring Port Description
PowerAlert Software
Communications Cable
WatchDog Compatibility
USB (HID enabled); DB9 Serial; Contact closure; EPO (emergency power off); Slot for SNMP/Web interface
Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 and contact closure
communications
Included
USB and DB9 cabling included
Supports Watchdog application, OS and hard-reboot restart options for remote applications
LINE / BATTERY TRANSFER
Transfer Time
Low Voltage Transfer to Battery
Power (Setpoint)
High Voltage Transfer to Battery
Power (Setpoint)
No transfer time (0 ms.) in online, double-conversion mode
80V (100% load), 70V (66% load), 60V (33% load)
144
SPECIAL FEATURES
Cold Start (Startup in Battery Mode
During a Power Failure)
High Availability UPS Features
Green Energy-Saving Features
Cold-start operation supported
Automatic inverter bypass; Hot swappable batteries
High efficiency economy mode operation; Individually controllable load banks; Schedulable daily hours of economy
mode operation
CERTIFICATIONS
UPS CertificationsTested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI)
WARRANTY
5 / 6
Product Warranty Period (Worldwide)
Connected Equipment Insurance
(U.S., Canada & Puerto Rico)
2-year limited warranty
$250,000 Ultimate Lifetime Insurance
© 2015 Tripp Lite. All rights reserved. All trademarks are the sole property of their respective owners. Tripp Lite has a policy of continuous improvement.
Specifications are subject to change without notice. Photos may differ slightly from final products.
6 / 6
2024年8月28日发(作者:种阳曦)
SmartOnline 100-127V 3kVA 2.5kW On-Line
Double-Conversion UPS, Extended Run, SNMP,
Webcard, 2U Rack/Tower, USB, DB9 Serial
MODEL NUMBER: SU3000RTXL2U
Highlights
3000VA / 3kVA / 2500 watt
on-line double-conversion 2U
rack/tower UPS
100/110/115/120/127V 50/60Hz
output, high efficiency economy
mode option
Expandable runtime, Hot-swap
batteries, 26 in / 66 cm installed
depth
USB, RS232 & EPO ports;
support for SNMP/WEB card
options
Front panel status LEDs with
detailed load and battery metering
2 independently switchable
output load banks
NEMA L5-30P input; L5-30R &
5-15/20R outlets
Description
3000VA / 3kVA / 2500 watt on-line, double-conversion UPS system for critical server, network and
telecommunications equipment. 2U rackmount form factor with an installed depth of only 26 inches (66cm).
Expandable battery runtime with optional BP72V15-2U (limit 1), BP72V28RT-3U (multi-pack compatible) and
BP72V18-2US (multi-pack compatible) external battery packs. Full time sine wave 100/110/115/120/127V output
with +/-2% voltage regulation. Uninterruptible Power Supply (UPS) actively converts raw incoming AC power to
DC, then re-converts output back to completely regulated, filtered AC output. Operates continuously without
using battery power during brownouts to 70V and overvoltages to 144V. Up to 97% efficiency in optional
economy mode saves BTU heat output and energy costs. NEMA L5-30P input plug. NEMA L5-30R, NEMA
5-15/20R and NEMA 5-15R output receptacles. Network-grade AC surge and noise suppression. Zero transfer
time between AC and battery operation. Network management interfaces include USB port, DB9 serial port and
SNMPWEBCARD slot. Built-in DB9 port offers both enhanced RS-232 enabled monitoring data, plus contact
closure monitoring ability. HID-compliant USB interface enables integration with built-in power management and
auto shutdown features of Windows and Mac OS X. Supports simultaneous detailed monitoring of equipment
load levels, self-test data and mains power conditions via all network interfaces. Includes PowerAlert monitoring
software and complete cabling. Emergency Power Off (EPO) interface. Integrated two bank PDU switching
Applications
Distributed Server Rooms
Network Closets
Small Business Networks
Voice over IP (VoIP) Phone
Systems
Package Includes
SU3000RTXL2U UPS System
4 post rackmount installation
brackets
PowerAlert Software CD and
cabling
Owner's manual with warranty
information
supports automated load shedding and remote-reboot of connected equipment. Multi-stage metered current monitoring and battery charge status LEDs.
Mains power and voltage regulation LEDs. Audible Alarm. Self-test. Fault-tolerant auto-bypass mode. LED display panel easily rotates for better viewing in
rackmount or tower configurations. Includes 4 post rackmount accessories. 2-9USTAND tower kit and 2POSTRMKITWM two post rackmount hardware
accessories available. Field replaceable, hot swappable internal batteries and external battery packs. $250,000 Ultimate Lifetime Insurance (U.S., Canada,
and Puerto Rico only).
Features
SmartOnline high-performance UPS system is ideal for critical voice, data, medical and industrial network applications
Optional economy-mode operation with 97% efficiency for reduced power consumption and cooler operation
1 / 6
Economy mode is schedulable via PowerAlert UPS management software for daily or weekly hours of operation to enable precision output during peak
operating hours and high efficiency, low BTU emission operation during off-peak times
Maintains continuous operation through blackouts, voltage fluctuations and surges
On-line, double-conversion mode provides perfectly regulated sine wave output within 2% of 100/110/115/120/127V (user selectable) with zero transfer
time
Supports operation at 50/60Hz (auto-sensing) with the ability for full-time frequency conversion from 50 to 60Hz or 60 to 50Hz (frequency conversion
de-rates UPS capacity by 20%)
Removes harmonic distortion, fast electrical impulses, frequency variations and other hard to solve power problems not addressed by other UPS types
Corrects line voltage conditions as low as 70V and as high as 144V to within 2% of selected nominal voltage
Standard internal battery set offers 15 minutes runtime at half load (1250W) and 6 minutes at full load (2500W)
Expandable battery runtime with optional BP72V15-2U (limit 1), BP72V28RT-3U (multi-pack compatible) and BP72V18-2US (multi-pack compatible)
external battery packs
Compact rackmount form factor installs using only 2 rack spaces (2U) with a depth of only 26 inches
Ships with all mounting accessories for 4 post rackmount installation
Optional 2POSTRMKITWM enables 2 post rackmount installation
Optional 2-9USTAND accessory enables upright tower placement
Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions
Network interfaces support simultaneous communications via built-in USB, DB9 serial / contact-closure and SNMPWEBCARD slot
HID compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Included
PowerAlert UPS monitoring software supports safe unattended shutdown, monitoring and control via local connected servers, plus any number of
additional servers over IP
UPS interface supports on-battery, low-battery, power-restored, AC-voltage, DC-voltage, output current monitoring, battery charge current, battery
capacity, AC line frequency, timed inverter shutoff, activate self-test, load bank output power control and remote reboot, UPS nominal voltage adjustment
and UPS line to battery power voltage setpoints
Built-in Emergency Power Off (EPO) interface with cable
NEMA L5-30P input plug / NEMA 5-15/20R & L5-30R output receptacles
Integrated 2 bank switched PDU enables remote outlet management for load shedding or remote reboot of individual load banks (each bank has 3 outlets)
Front panel LEDs offer current monitoring and battery charge level information
Network grade AC surge suppression
Field replaceable, hot swappable internal batteries and external battery packs
$250,000 Ultimate Lifetime Insurance (U.S., Canada, and Puerto Rico only)
Specifications
OUTPUT
Output Capacity Details
Output Volt Amp Capacity (VA)
Output kVA Capacity (kVA)
Output Watt Capacity (Watts)
Output kW Capacity (kW)
Power Factor
Max output is 3000VA 2400W at 100V, 110V, 115V nominal settings
3000
3
2500
2.5
0.83
2 / 6
Crest Factor
Nominal Output Voltage(s)
Supported
Nominal Voltage Details
Frequency Compatibility
Frequency Compatibility Details
Output Voltage Regulation (Line
Mode)
Output Voltage Regulation
(Economy Line Mode)
Output Voltage Regulation (Battery
Mode)
Output Receptacles
Load Management Receptacles
Output Circuit Breakers
Output AC Waveform (AC Mode)
Output AC Waveform (Battery Mode)
3:1
100V; 110V; 115V; 120V; 127V
120V default
50 / 60 Hz
Output frequency matches input nominal on startup, defaults to 60 Hz on cold-start. Frequency conversion from 60
to 50 Hz -or- 50 to 60 Hz supported. Output capacity de-rates by 25% during frequency conversion operation.
+/- 2%
-12%, + 10%
+/- 2%
(6) 5-15/20R; (1) L5-30R
Two switchable three-outlet load banks
20A (x2) - each breaker protects 3 5-15/20R outlets, L5-30R outlet is un-breakered
Pure Sine wave
Pure Sine wave
INPUT
Rated input current (Maximum Load)
Nominal Input Voltage(s) Supported
UPS Input Connection Type
Recommended Electrical Service
Input Cord Length (ft.)
Input Cord Length (m)
Input Phase
24A
100V AC; 110V AC; 115V AC; 120V AC; 127V AC
L5-30P
30A 120V
10
3
Single-Phase
BATTERY
Full Load Runtime (min.)
Half Load Runtime (min.)
Expandable Battery Runtime
External Battery Pack Compatibility
DC System Voltage (VDC)
Battery Recharge Rate (Included
Batteries)
Internal UPS Replacement Battery
Cartridge
Battery Access
6 min. (2500w)
15 min. (1250w)
Supports extended runtime with optional external battery packs
BP72V15-2U (limit 1); BP72V28RT-3U (multi-pack compatible); BP72V18-2US (multi-pack compatible)
72
Less than 4.8 hours from 10% to 90% (typical, full load discharge)
RBC96-2U
Front panel battery access door
3 / 6
Battery Replacement DescriptionHot-swappable, user replaceable batteries
VOLTAGE REGULATION
Voltage Regulation Description
Overvoltage Correction
Undervoltage Correction
Severe Undervoltage Correction
Online, double-conversion power conditioning
2% output voltage regulation during overvoltages to 144
2% output voltage regulation during undervoltages to 80
2% output voltage regulation during undervoltages to 70V (under 66% load only) or 60V (under 33% load only)
LEDS ALARMS & SWITCHES
LED Indicators
Audible Alarm
Alarm Cancel Operation
Switches
14 LEDs indicate line power, online mode, economy/bypass mode, on-battery, overload, battery low, replace battery
and fault status information; 4-LED meter displays load and battery charge levels; LED panel rotates for viewing in
rack/tower formats
Audible alarm indicates power failure, low battery, overload, replace battery and EPO operation
Power-fail alarm can be silenced using alarm-cancel switch
2 Switches control off/on power status and alarm-cancel/self-test operation
SURGE / NOISE SUPPRESSION
UPS AC Suppression Joule Rating
EMI / RFI AC Noise Suppression
AC Suppression Response Time
504 joules
Yes
Instantaneous
PHYSICAL
Included Mounting Accessory
Description
Installation Form Factors Supported
with Optional Accessories
Primary Form Factor
UPS Power Module Dimensions
(hwd, in.)
UPS Power Module Dimensions
(hwd, cm)
Rack Height (U Spaces)
UPS Power Module Weight (lbs.)
UPS Power Module Weight (kg)
UPS Shipping Dimensions (hwd / in.)
UPS Shipping Dimensions (hwd /
cm)
Shipping Weight (lbs.)
Shipping Weight (kg)
Cooling Method
Includes 4 post rackmount installation accessories
2 post rackmount (2POSTRMKITWM); Tower (2-9USTAND)
Rackmount
3.5 x 17.3 x 26
8.9 x 43.9 x 66
2
68.8
31.2
9 x 22 x 32.8
22.9 x 55.9 x 83.3
78.3
35.5
Fan
4 / 6
UPS Housing MaterialSteel
ENVIRONMENTAL
Operating Temperature Range
Storage Temperature Range
Relative Humidity
AC Mode BTU / Hr. (Full Load)
AC Economy Mode BTU / Hr. (Full
Load)
Battery Mode BTU / Hr. (Full Load)
AC Mode Efficiency Rating (100%
Load)
AC Economy Mode Efficiency Rating
(100% Load)
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius.
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius.
0 to 95%, non-condensing
1000
241
1500
89%
97%
COMMUNICATIONS
Communications Interface
Network Monitoring Port Description
PowerAlert Software
Communications Cable
WatchDog Compatibility
USB (HID enabled); DB9 Serial; Contact closure; EPO (emergency power off); Slot for SNMP/Web interface
Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 and contact closure
communications
Included
USB and DB9 cabling included
Supports Watchdog application, OS and hard-reboot restart options for remote applications
LINE / BATTERY TRANSFER
Transfer Time
Low Voltage Transfer to Battery
Power (Setpoint)
High Voltage Transfer to Battery
Power (Setpoint)
No transfer time (0 ms.) in online, double-conversion mode
80V (100% load), 70V (66% load), 60V (33% load)
144
SPECIAL FEATURES
Cold Start (Startup in Battery Mode
During a Power Failure)
High Availability UPS Features
Green Energy-Saving Features
Cold-start operation supported
Automatic inverter bypass; Hot swappable batteries
High efficiency economy mode operation; Individually controllable load banks; Schedulable daily hours of economy
mode operation
CERTIFICATIONS
UPS CertificationsTested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI)
WARRANTY
5 / 6
Product Warranty Period (Worldwide)
Connected Equipment Insurance
(U.S., Canada & Puerto Rico)
2-year limited warranty
$250,000 Ultimate Lifetime Insurance
© 2015 Tripp Lite. All rights reserved. All trademarks are the sole property of their respective owners. Tripp Lite has a policy of continuous improvement.
Specifications are subject to change without notice. Photos may differ slightly from final products.
6 / 6