Optical reading head
Technical data
PCV100I-F200-SSI-V19
Model Number
PCV100I-F200-SSI-V19
Read head for incident light positioning
system
Features
•SSI interface
•Non-contact positioning on Data
Matrix code tape
•Mechanically rugged: no wearing
parts, long operating life, mainte-
nance-free
•High resolution and precise posi-
tioning, especially for facilities
with curves and switch points as
well as inclines and declines.
•Travel ranges up to 10 km, in X and
Y direction
•Infrared light
Diagrams
Coordinates
Y
R
e
l
e
a
s
e
d
a
t
e
:
2
0
1
7
-
0
3
-
2
4
1
3
:
1
2
D
a
t
e
o
f
i
s
s
u
e
:
2
0
1
7
-
0
3
-
2
4
2
4
2
7
0
7
_
e
n
g
.
x
m
l
Z
X
General specifications
Passage speed v≤ 8 m/s
Measuring range max. 10000 m
Light type Integrated LED lightning , infrared
Read distance 100 mm
Depth of focus ± 20 mm
Reading field 50 mm x 30 mm
Ambient light limit 100000 Lux
Resolution ± 0.1 mm
Nominal ratings
Camera
Type CMOS , Global shutter
Processor
Clock pulse frequency 600 MHz
Speed of computation 4800 MIPS
Functional safety related parameters
MTTF
d
84 a
Mission Time (T
M
) 42 a
Diagnostic Coverage (DC) 0 %
Indicators/operating means
LED indicator 7 LEDs (communication, alignment aid, status information)
Electrical specifications
Operating voltage U
B
15 ... 30 V DC , PELV
No-load supply current I
0
max. 200 mA
Power consumption P
0
3 W
Interface 1
Interface type SSI interface
Data output code Gray code, binary code , programmable
Monoflop time T
m
= 10 µs
Clock frequency 100 ... 1000 kHz
Query cycle time ≥ 3 ms
Pause time tp≥ 20 µs
double request possible, if t
p
≤ 10 µs
Interface 2
Interface type USB (serial comport)
Protocol 8E1
Transfer rate 38.4 ... 460.8 kBit/s
Input
Input type 1 to 2 functional inputs , programmable
Input impedance ≥ 27 kΩ
Output
Output type 1 to 2 switch outputs , PNP , programmable , short-circuit
protected
Switching voltage Operating voltage
Switching current 150 mA each output
Standard conformity
Emitted interference EN61000-6-4:2007+A1:2011
Noise immunity EN 61000-6-2:2005
Shock resistance EN 60068-2-27:2009
Vibration resistance EN 60068-2-6:2008
Ambient conditions
Operating temperature 0 ... 60 °C (32 ... 140 °F) , -20 ... 60 °C (-4 ... 140 °F)
(noncondensing; prevent icing on the lens!)
Storage temperature -20 ... 85 °C (-4 ... 185 °F)
Relative humidity 90 % , noncondensing
Mechanical specifications
Connection type 8-pin, M12 x 1 connector
Housing width 70 mm
Housing height 70 mm
Degree of protection IP67
Material
Housing PC/ABS
Mass approx. 160 g
Approvals and certificates
UL approval
CCC approval
cULus Listed, General Purpose, Class 2 Power Source,
Type 1 enclosure
CCC approval / marking not required for products rated ≤36
V
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
Pepperl+Fuchs GroupUSA: +1 330 486 0001Germany: +49 621 776 4411
************************.************************.com
Singapore: +65 6779 9091
************************.com
1
Optical reading head
Dimensions
PCV100I-F200-SSI-V19
Additional Information
4
x
M
6
M
1
2
x
1
ADJUST
CONFIG
1
2
5
1
ø
2
5
2
2
1
7
0
8
0
2
4
0
1
2
C
O
M
S
E
R
V
I
C
E
P
W
R
/
A
D
J
E
R
R
/
N
O
C
O
D
E
S
S
I
D
A
T
A
/
C
O
N
F
I
G
O
U
T
3
/
A
D
J
Z
O
U
T
2
/
A
D
J
Y
38.5
7014.5
LED 1 2 3 4 5 6 7
Electrical Connection
1
2
3
4
5
6
7
8
OUT 2 / IN 2
+ UB
Data +
Data -
CLK+
CLK-
GND
OUT 3 / IN 3
Accessories
V19-G-ABG-PG9
Female connector, M12, 8-pin, shielded,
field attachable
V19-G-ABG-PG9-FE
Female connector, M12, 8-pin, shielded,
field attachable
PCV-KBL-V19-STR-USB
USB cable unit with power supply
PCV-SC12
Grounding clip for PCV system
PCV-LM25
Marker head for 25 mm code tape
PCV-MB1
Mounting bracket for PCV* read head
8
1
2
3
4
Vision Configurator
Operating software for camera-based
sensors
7
6
5
General
The PCV… reading head is part of the positioning system in the method for measurement by Pepperl+Fuchs. It
consists of a camera module and an integrated illumination unit among other things. The reading head detects po-
sition marks, which are put on an adhesive code band in the form of Data Matrix code. The mounting of the code
band is as a rule stationary on a firm part of the plant (elevator shaft, overhead conveyor mounting rails…); that of
the reading head is parallel on the moving "vehicle" (elevator car, overhead conveyor chassis…).
Mounting and commissioning
Mount the reading head such that its optical surface captures the optimal read distance to the code band (see Tech-
2
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
Pepperl+Fuchs GroupUSA: +1 330 486 0001Germany: +49 621 776 4411
************************.************************.com
Singapore: +65 6779 9091
************************.com
R
e
l
e
a
s
e
d
a
t
e
:
2
0
1
7
-
0
3
-
2
4
1
3
:
1
2
D
a
t
e
o
f
i
s
s
u
e
:
2
0
1
7
-
0
3
-
2
4
2
4
2
7
0
7
_
e
n
g
.
x
m
l
Pinout
PCV-AG100
Alignment guide for PCV100-* read head
I
N
T
E
R
N
A
L
D
I
A
G
N
O
S
T
I
C
9
Optical reading headPCV100I-F200-SSI-V19
nical Data). The stability of the mounting and the guidance of the vehicle must be provided such that the depth of field of the reading head is not closed during operation.
All reading heads can be optimally customized by parameterization for specific requirements.
Displays and Controls
reading head allows visual function check and fast diagnosis with 7 indicator LEDs. The reading head has 2 buttons on the reverse of the device to activate the
alignment aid and parameterization mode.
LEDs
LED
1
2
3
4
5
6,7
Color
Yellow
Green/red
Yellow
Yellow
Yellow
red/green/yellow
Label
COM
PWR/ADJ
ERR/NO CODE
SSI DATA/CONFIG
OUT2/ADJ Y
OUT3/ADJ Z
INTERNAL
DIAGNOSTICS
Meaning
USB interface, communication active
Code recognized/not recognized, Error
Data flow on SSI interface / configuration
Output 2, Alignment aid Y
Output 3, Alignment aid Z
Internal diagnostics
Data protocol
Data
1112
XP21XP20XP19XP18XP17XP16XP15XP14XP13XP12XP11XP10
MSB
13
XP9
14
XP8
15
XP7
16
XP6
17
XP5
18
XP4
19
XP3
20
XP2
21
XP1
22
XP0
LSB
23
Out
2425
WrnErr
Status bits
Position data is coded in XP0 ... XP21 (MSB first)
Meaning of the status bits
Out
X
X
1
Err
X
1
X
Wrn
1
X
X
Meaning
reserved
Error, error code in XP0 ... XP21
No codes in read window (XP0 ... XP21 = 0)
Error codes
Error code
1
2
>1000
Meaning
reverse reading head orientation (180° contorted)
position error: unsecure position codes in reading window
internal error
External parameterization
For external parameterization you require the parameterization code as Data Matrix with the desired reading head parameters. Data Matrix code cards for step-by-step external
parameterization are printed in the reading heads operating instructions.
Parameterization is only possible within 10 minutes of switching on the reading head. If a button is pressed after 10 minutes subsequent to switching on, there is visual signaling
via the LEDs (LED1, yellow/LED2, red/LED3, yellow/LED4, yellow/LED5, yellow flash for 2 seconds)
•The switchover from normal operation to parameterization mode is via button 2 on the reverse of the reading head. Button 2 must be pressed for more than 2 seconds.
LED3 now flashes.
Note:Parameterization mode automatically ends after 1 minute of inactivity. The reading head returns to normal operation and works with unchanged settings.
•Place the parameterization code in the view of the camera module. After recognition of the parameterization code, the green LED2 lights up for 1s. In the event of an
invalid parameterization code, the red LED2 lights up for 2 s.
•A short press on button 2 ends the parameterization mode and the changed parameters are not stored volatile in the reading head.
Alignment aid for the Y and Z coordinates
The activation of the alignment aid is only possible within 10 minutes of switching on the reading head. The switchover from normal operation to “alignment aid operating mode
is via button 1 on the reverse of the reading head.
•Press the button 1 for longer than 2 s. LED2 flashes green for a recognized code band. LED2 flashes red for an unrecognized code band.
•Z coordinate: If the distance of the camera to the code band too small, the yellow LED5 lights up. If the distance of the camera to the code band too large, the yellow
LED5 lights up. Within the target range, the yellow LED5 flashes at the same time as the green LED2.
•Y coordinate: If the optical axis of the camera is too deep in relation to the middle of the code band, the yellow LED4 lights up. If the optical axis is too high, the yellow
LED4 extinguishes. Within the target range, the yellow LED4 flashes at the same time as the green LED2.
•A short press on button 1 ends the alignment aid and the reading head changes to normal operation.
R
e
l
e
a
s
e
d
a
t
e
:
2
0
1
7
-
0
3
-
2
4
1
3
:
1
2
D
a
t
e
o
f
i
s
s
u
e
:
2
0
1
7
-
0
3
-
2
4
2
4
2
7
0
7
_
e
n
g
.
x
m
l
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
Pepperl+Fuchs GroupUSA: +1 330 486 0001Germany: +49 621 776 4411
************************.************************.com
Singapore: +65 6779 9091
************************.com
3
2024年8月31日发(作者:伏凌兰)
Optical reading head
Technical data
PCV100I-F200-SSI-V19
Model Number
PCV100I-F200-SSI-V19
Read head for incident light positioning
system
Features
•SSI interface
•Non-contact positioning on Data
Matrix code tape
•Mechanically rugged: no wearing
parts, long operating life, mainte-
nance-free
•High resolution and precise posi-
tioning, especially for facilities
with curves and switch points as
well as inclines and declines.
•Travel ranges up to 10 km, in X and
Y direction
•Infrared light
Diagrams
Coordinates
Y
R
e
l
e
a
s
e
d
a
t
e
:
2
0
1
7
-
0
3
-
2
4
1
3
:
1
2
D
a
t
e
o
f
i
s
s
u
e
:
2
0
1
7
-
0
3
-
2
4
2
4
2
7
0
7
_
e
n
g
.
x
m
l
Z
X
General specifications
Passage speed v≤ 8 m/s
Measuring range max. 10000 m
Light type Integrated LED lightning , infrared
Read distance 100 mm
Depth of focus ± 20 mm
Reading field 50 mm x 30 mm
Ambient light limit 100000 Lux
Resolution ± 0.1 mm
Nominal ratings
Camera
Type CMOS , Global shutter
Processor
Clock pulse frequency 600 MHz
Speed of computation 4800 MIPS
Functional safety related parameters
MTTF
d
84 a
Mission Time (T
M
) 42 a
Diagnostic Coverage (DC) 0 %
Indicators/operating means
LED indicator 7 LEDs (communication, alignment aid, status information)
Electrical specifications
Operating voltage U
B
15 ... 30 V DC , PELV
No-load supply current I
0
max. 200 mA
Power consumption P
0
3 W
Interface 1
Interface type SSI interface
Data output code Gray code, binary code , programmable
Monoflop time T
m
= 10 µs
Clock frequency 100 ... 1000 kHz
Query cycle time ≥ 3 ms
Pause time tp≥ 20 µs
double request possible, if t
p
≤ 10 µs
Interface 2
Interface type USB (serial comport)
Protocol 8E1
Transfer rate 38.4 ... 460.8 kBit/s
Input
Input type 1 to 2 functional inputs , programmable
Input impedance ≥ 27 kΩ
Output
Output type 1 to 2 switch outputs , PNP , programmable , short-circuit
protected
Switching voltage Operating voltage
Switching current 150 mA each output
Standard conformity
Emitted interference EN61000-6-4:2007+A1:2011
Noise immunity EN 61000-6-2:2005
Shock resistance EN 60068-2-27:2009
Vibration resistance EN 60068-2-6:2008
Ambient conditions
Operating temperature 0 ... 60 °C (32 ... 140 °F) , -20 ... 60 °C (-4 ... 140 °F)
(noncondensing; prevent icing on the lens!)
Storage temperature -20 ... 85 °C (-4 ... 185 °F)
Relative humidity 90 % , noncondensing
Mechanical specifications
Connection type 8-pin, M12 x 1 connector
Housing width 70 mm
Housing height 70 mm
Degree of protection IP67
Material
Housing PC/ABS
Mass approx. 160 g
Approvals and certificates
UL approval
CCC approval
cULus Listed, General Purpose, Class 2 Power Source,
Type 1 enclosure
CCC approval / marking not required for products rated ≤36
V
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
Pepperl+Fuchs GroupUSA: +1 330 486 0001Germany: +49 621 776 4411
************************.************************.com
Singapore: +65 6779 9091
************************.com
1
Optical reading head
Dimensions
PCV100I-F200-SSI-V19
Additional Information
4
x
M
6
M
1
2
x
1
ADJUST
CONFIG
1
2
5
1
ø
2
5
2
2
1
7
0
8
0
2
4
0
1
2
C
O
M
S
E
R
V
I
C
E
P
W
R
/
A
D
J
E
R
R
/
N
O
C
O
D
E
S
S
I
D
A
T
A
/
C
O
N
F
I
G
O
U
T
3
/
A
D
J
Z
O
U
T
2
/
A
D
J
Y
38.5
7014.5
LED 1 2 3 4 5 6 7
Electrical Connection
1
2
3
4
5
6
7
8
OUT 2 / IN 2
+ UB
Data +
Data -
CLK+
CLK-
GND
OUT 3 / IN 3
Accessories
V19-G-ABG-PG9
Female connector, M12, 8-pin, shielded,
field attachable
V19-G-ABG-PG9-FE
Female connector, M12, 8-pin, shielded,
field attachable
PCV-KBL-V19-STR-USB
USB cable unit with power supply
PCV-SC12
Grounding clip for PCV system
PCV-LM25
Marker head for 25 mm code tape
PCV-MB1
Mounting bracket for PCV* read head
8
1
2
3
4
Vision Configurator
Operating software for camera-based
sensors
7
6
5
General
The PCV… reading head is part of the positioning system in the method for measurement by Pepperl+Fuchs. It
consists of a camera module and an integrated illumination unit among other things. The reading head detects po-
sition marks, which are put on an adhesive code band in the form of Data Matrix code. The mounting of the code
band is as a rule stationary on a firm part of the plant (elevator shaft, overhead conveyor mounting rails…); that of
the reading head is parallel on the moving "vehicle" (elevator car, overhead conveyor chassis…).
Mounting and commissioning
Mount the reading head such that its optical surface captures the optimal read distance to the code band (see Tech-
2
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
Pepperl+Fuchs GroupUSA: +1 330 486 0001Germany: +49 621 776 4411
************************.************************.com
Singapore: +65 6779 9091
************************.com
R
e
l
e
a
s
e
d
a
t
e
:
2
0
1
7
-
0
3
-
2
4
1
3
:
1
2
D
a
t
e
o
f
i
s
s
u
e
:
2
0
1
7
-
0
3
-
2
4
2
4
2
7
0
7
_
e
n
g
.
x
m
l
Pinout
PCV-AG100
Alignment guide for PCV100-* read head
I
N
T
E
R
N
A
L
D
I
A
G
N
O
S
T
I
C
9
Optical reading headPCV100I-F200-SSI-V19
nical Data). The stability of the mounting and the guidance of the vehicle must be provided such that the depth of field of the reading head is not closed during operation.
All reading heads can be optimally customized by parameterization for specific requirements.
Displays and Controls
reading head allows visual function check and fast diagnosis with 7 indicator LEDs. The reading head has 2 buttons on the reverse of the device to activate the
alignment aid and parameterization mode.
LEDs
LED
1
2
3
4
5
6,7
Color
Yellow
Green/red
Yellow
Yellow
Yellow
red/green/yellow
Label
COM
PWR/ADJ
ERR/NO CODE
SSI DATA/CONFIG
OUT2/ADJ Y
OUT3/ADJ Z
INTERNAL
DIAGNOSTICS
Meaning
USB interface, communication active
Code recognized/not recognized, Error
Data flow on SSI interface / configuration
Output 2, Alignment aid Y
Output 3, Alignment aid Z
Internal diagnostics
Data protocol
Data
1112
XP21XP20XP19XP18XP17XP16XP15XP14XP13XP12XP11XP10
MSB
13
XP9
14
XP8
15
XP7
16
XP6
17
XP5
18
XP4
19
XP3
20
XP2
21
XP1
22
XP0
LSB
23
Out
2425
WrnErr
Status bits
Position data is coded in XP0 ... XP21 (MSB first)
Meaning of the status bits
Out
X
X
1
Err
X
1
X
Wrn
1
X
X
Meaning
reserved
Error, error code in XP0 ... XP21
No codes in read window (XP0 ... XP21 = 0)
Error codes
Error code
1
2
>1000
Meaning
reverse reading head orientation (180° contorted)
position error: unsecure position codes in reading window
internal error
External parameterization
For external parameterization you require the parameterization code as Data Matrix with the desired reading head parameters. Data Matrix code cards for step-by-step external
parameterization are printed in the reading heads operating instructions.
Parameterization is only possible within 10 minutes of switching on the reading head. If a button is pressed after 10 minutes subsequent to switching on, there is visual signaling
via the LEDs (LED1, yellow/LED2, red/LED3, yellow/LED4, yellow/LED5, yellow flash for 2 seconds)
•The switchover from normal operation to parameterization mode is via button 2 on the reverse of the reading head. Button 2 must be pressed for more than 2 seconds.
LED3 now flashes.
Note:Parameterization mode automatically ends after 1 minute of inactivity. The reading head returns to normal operation and works with unchanged settings.
•Place the parameterization code in the view of the camera module. After recognition of the parameterization code, the green LED2 lights up for 1s. In the event of an
invalid parameterization code, the red LED2 lights up for 2 s.
•A short press on button 2 ends the parameterization mode and the changed parameters are not stored volatile in the reading head.
Alignment aid for the Y and Z coordinates
The activation of the alignment aid is only possible within 10 minutes of switching on the reading head. The switchover from normal operation to “alignment aid operating mode
is via button 1 on the reverse of the reading head.
•Press the button 1 for longer than 2 s. LED2 flashes green for a recognized code band. LED2 flashes red for an unrecognized code band.
•Z coordinate: If the distance of the camera to the code band too small, the yellow LED5 lights up. If the distance of the camera to the code band too large, the yellow
LED5 lights up. Within the target range, the yellow LED5 flashes at the same time as the green LED2.
•Y coordinate: If the optical axis of the camera is too deep in relation to the middle of the code band, the yellow LED4 lights up. If the optical axis is too high, the yellow
LED4 extinguishes. Within the target range, the yellow LED4 flashes at the same time as the green LED2.
•A short press on button 1 ends the alignment aid and the reading head changes to normal operation.
R
e
l
e
a
s
e
d
a
t
e
:
2
0
1
7
-
0
3
-
2
4
1
3
:
1
2
D
a
t
e
o
f
i
s
s
u
e
:
2
0
1
7
-
0
3
-
2
4
2
4
2
7
0
7
_
e
n
g
.
x
m
l
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
Pepperl+Fuchs GroupUSA: +1 330 486 0001Germany: +49 621 776 4411
************************.************************.com
Singapore: +65 6779 9091
************************.com
3