最新消息: USBMI致力于为网友们分享Windows、安卓、IOS等主流手机系统相关的资讯以及评测、同时提供相关教程、应用、软件下载等服务。

LG RESU7H LG RESU10H与SUN2000L电池连接说明说明书

IT圈 admin 39浏览 0评论

2024年10月5日发(作者:黄含莲)

Battery & Energy Meter

Quick Guide

Issue: 01

Date: 2017-12-14

Copyright © Huawei Technologies Co., Ltd. 2017. All rights reserved.

1

Preparing Cables

NOTICE

The battery output voltage

should always be lower

than or equal to 500 V DC.

NOTE

NOTE

The CAN_H and CAN_L ports of the battery are not used in this document.

This chapter describes the

CHINT-DDSU666 energy

meter. For information about

more energy meters, see

Chapter 3 Energy Meter

Cables Connection.

1.1

Preparing the Battery Cables

e the battery switch between theLG RESU7H/LG RESU10H and the SUN2000L.

Component

Battery switch

Description

Recommended: a DC circuit breaker with a rated voltage greater than

or equal to 600 V DC and a rated current of 20 A

Source

Prepared by the customer

e the power cable between theLG RESU7H/LG RESU10H and the SUN2000L.

CableLG

RESU7H/LG

RESU10H

SUN2000L

TypeConductor Cross-

sectional Area

Range

4–6 mm

2

4–6 mm

2

Outer

Diameter

N/A

4.5–7.8

mm

Source

Ground wire

Negative line of

the power cable

Positive line of the

power cable

-

+

N/A

BAT-

BAT+

Single-core outdoor

copper cable

Standard PV cable in

the industry

(recommended model:

PV1-F)

Prepared by the

customer

Prepared by the

customer

e the battery communications cable between theLG RESU7H/LG RESU10H and the SUN2000L.

Cable

Communications

cable

LG RESU7H/LG

RESU10H

2) EN GND

3)ENABLE_H

4) RS485_H

5) RS485_L

(COM)

SUN2000L

5) EN-

6) EN+

4) 485A2

3) 485B2

Type

Four-core

outdoor

shielded

twisted pair

Conductor Cross-

sectional Area Range

0.25–1 mm

2

Outer

Diameter

4–11 mm

Source

Prepared by the

customer

1

1.2

Preparing the Energy Meter Cables

e the AC switch between the energy meter and the SUN2000L.

Component

AC switch

Description

Recommended: a single-phase AC circuit breaker with a rated voltage

greater than or equal to 250 V AC and a rated current of

•16 A (SUN2000L-2KTL)

•25 A (SUN2000L-3KTL and SUN2000L-3.68KTL)

•32 A (SUN2000L-4KTL, SUN2000L-4.6KTL, and SUN2000L-5KTL)

Source

Prepared by the customer

e cables between the energy meter and the SUN2000L.

CHINT-DDSU666

CableCHINT-

DDSU666

1) L

3) N

(AC)

SUN2000L

L

N

Type

Two-core (L and N)

outdoor copper

cable

Conductor Cross-

sectional Area Range

4–6 mm

2

Outer

Diameter

10–21 mm

Source

Prepared by the

customer

AC output power

cable between the

energy meter and

the SUN2000L

Cable

Communications

cable

CHINT-

DDSU666

RS485A(+)

RS485B(-)

(COM)

SUN2000L

2) 485A1

1) 485B1

Type

Four-core outdoor

shielded twisted

pair

Conductor Cross-

sectional Area Range

0.25–1 mm

2

Outer

Diameter

4–11 mm

Source

Prepared by the

customer

EM111DINAV81XS1X

CableEM111DINA

V81XS1X

2) L

N

(AC)

SUN2000L

L

N

Type

Two-core (L and N)

outdoor copper cable

Conductor Cross-

sectional Area Range

4–6 mm

2

Outer

Diameter

10–21 mm

Source

Prepared by the

customer

AC output power

cable between the

energy meter and

the SUN2000L

Cable

Communications

cable

EM111DINAV81X

S1X

6) B+

(COM)

SUN2000L

2) 485A1

Type

Four-core

outdoor

shielded

twisted pair

Conductor Cross-

sectional Area Range

0.25–1 mm

2

Outer

Diameter

4–11 mm

Source

Prepared by the

customer

8) A-1) 485B1

EM340DINAV23XS1X

CableEM340DINA

V23XS1X

4) L

N

EM340DINAV23X

S1X

8) B+

9) A-

(AC)

SUN2000L

L

N

(COM)

SUN2000L

2) 485A1

1) 485B1

Type

Two-core (L and N)

outdoor copper

cable

Conductor Cross-

sectional Area Range

4–6 mm

2

Outer

Diameter

10–21 mm

Source

Prepared by the

customer

AC output power

cable between the

energy meter and the

SUN2000L

Cable

Communications

cable

Type

Four-core

outdoor

shielded

twisted pair

Conductor Cross-

sectional Area Range

0.25–1 mm

2

Outer

Diameter

4–11 mm

Source

Prepared by the

customer

NOTICE

If a connector needs to connect to two signal cables, ensure that the cables have the same outer diameter.

2

2

Battery Cables Connection

2.1

Connecting the Battery Cables to the Battery Pack

NOTICE

Make sure that the Auxiliary Power ON/OFF switch and the Circuit Breaker switch of the battery pack are turned off before connecting

the power cable to the battery pack.

Make sure that the inverter AC and DC disconnections are turned off before connecting the power cable to the battery pack.

t the Communications Cable.

t the power cable.

a)Connect the ground wire to terminal 1.

b)Connect the negative line of the power cable to terminal 2.

c)Connect the positive line of the power cable to terminal 3.

At first, connect the wire to terminal 2. Then, make

connections to the 3, 4, and 5 terminals one after another.

2.2

Connecting the Battery Cables to the SUN2000L

DANGER

Do not connect or disconnect battery cables when the SUN2000L is running. Failing to do so may cause electric shocks.

Before connecting battery cables, ensure that the DC switch on the SUN2000L and all the switches connecting to the SUN2000L are OFF,

and the SUN2000L has no residual electricity. Otherwise, the high voltage of the SUN2000L and battery may result in electric shocks.

If no battery connects to the SUN2000L, do not remove the watertight cap from the battery terminal. Otherwise, the SUN2000L willnot

comply with its Ingress Protection Rating. If a battery connects to the SUN2000L, set aside the watertight cap. Reinstall thewatertight cap

immediately after removing the connector. The high voltage of the battery terminal may result in electric shocks.

le the blue positive and negative connectors, and then connect the power cable.

Positive metal terminal

Positive connector

Ensure that

the locking nut

is secured.

Negative metal terminal

Ensure that the cable will not

be extracted after crimped.

Negative connector

Pull the power cable back to ensure that it

is connected securely.

Click

Savethe watertight

caps for later use.

Pull the battery cable back to ensure

that it is connected securely.

WARNING

Do not connect any load between the SUN2000L and the battery.

Ensure that the following conditions are met. Otherwise, the SUN2000L will be damaged, or even become a fire hazard.

The battery cable is connected correctly. That is, the positive and negative terminals of the battery connect to the positive battery terminal

and negative battery terminal on the SUN2000L respectively.

The cable between the battery and the SUN2000L should be less than or equal to 10 meters, and within 5 meters is recommended.

The battery voltage can result in fatal injury. Use dedicated insulation tools to terminate cables.

Ensure that the battery cable is correctly connected. Avoid reverse polarity.

3

t the communications cable.

No.

3

4

LabelDefinition

RS485B, RS485

485B2

differential signal–

485A2

RS485A, RS485

differential signal+

NOTICE

5

6

8

EN–

EN+

PE

Enable signal–

Enable signal+

Grounding the shield layer

When laying out signal cables, separate

them from power cables to avoid strong

signal interference sources.

The protection layer of the signal cable is

in the connector. Surplus core wires are

cut off from the protection layer. The

exposed core wire is totally inserted into

the cable hole and connected securely.

3

a)

3.1

Connecting the Energy Meter Cables to the SUN2000L

t the AC output power cable to the SUN2000L.

Connect the AC output power cable to the AC connector.

Energy Meter Cables Connection

Connection

Click

b)Connect the AC connector to the AC output port.

c)Check the route of the AC

output power cable.

t the communications cable to the SUN2000L.

4

3.2

Connecting the Energy Meter Cables to the Energy Meter

CHINT-DDSU666

Open the front cover, and then connect the cable to the CHINT-DDSU666.

Top view

4) N

8) RS485B

7) RS485A

3) N

SUN2000L

7) 485A

8) 485B

3) N4) N

COM

1) 485B1

2) 485A1

AC

LN

Power grid

Side view

Front cover

AC

switch

CHINT-DDSU666

1) L

2) L

Front cover

L

Bottom view

1) L

5) P+

6) PQ-

2) L

NL

Load

NOTE

The P+ and PQ+ ports are not used in this document.

It is recommended that the energy meter be installed in the original residential power

distribution unit. The energy meter can also be independently installed outside the original

residential power distribution unit.

EM111DINAV81XS1X

Open the front cover, and then connect the cable to the EM111DINAV81XS1X.

LL

SUN2000L

COM

2) 485A11) 485B1

AC

LN

B+

Power grid

A-

AC

switch

Residential power

distribution unit

NOTE

It is recommended that the energy meter be installed in

the original residential power distribution unit. The

energy meter can also be independently installed

outside the original residential power distribution unit.

NL

Load

5

EM340DINAV23XS1X

Open the front cover, and then connect the cable to the EM340DINAV23XS1X.

L1L2L3

COM

2) 485A11) 485B1

AC

L

N

EM340DINAV23XS1X

AC

switch

B+

A-

Power grid

L1L2L3

NOTE

It is recommended that the energy meter be

installed in the original residential power

distribution unit. The energy meter can also be

independently installed outside the original

residential power distribution unit.

NL1L2L3

Residential power

distribution unit

Load

3

Commissioning

3.1

Powering On the System

the battery pack in operation by taking the following steps:

a)Turn on the Auxiliary Power ON/OFF switch after installing the battery pack. Make sure that the Circuit Breaker switch is in theOFF

position (including the Trip position).

b)Set the Circuit Breaker switch to the ON position.

Auxiliary Power ON/OFF switch Circuit Breaker switch

c)Several seconds after the Circuit Breaker switch is set to ON, 4 LEDs will be lit.

d)Make sure that ON indicator is on and see if the battery pack is successfully initialized. The power-on indicator on the front should turn on

in green.

e)Close the wiring box cover.

6

on the SUN2000L:

NOTICE

.

Before turning on the AC switch between the SUN2000L and the power grid, check that the AC voltage on the power grid side of the AC

switch is within the specified range.

If the DC is on and the AC is off, the SUN2000L reports a Grid Failurealarm. The SUN2000L starts normally only after the fault is rectified.

If the AC is on and the battery is off, the SUN2000L reports a Battery Abnormal alarm.

(A) PV string

(D) AC switch

(G) Residential power meter

(J) Battery switch

(B) DC switch

(E)Residential power distribution unit

(H) Power grid

(K) Alarm beacon

(C) SUN2000L

(F) Energy meter

(I) Battery

(L) Residential load

a)Turn on the battery switch between the battery pack and the SUN2000L.

b)Turn on the AC switchbetween the SUN2000L and the power grid.

NOTICE

If the SUN2000L is connected to the battery, after turning on the AC switch:

If the DC switch is turned on within 1 minute, the SUN2000L will run properly in grid-tied mode.

If the DC switch is not turned on within 1 minute, the SUN2000L will enter the nighttime grid-tied mode. Then, after the DC switch is

turned on, the SUN2000L will shut down and then restart to run in grid-tied mode.

c)Turn on the DC switch between the PV string and the SUN2000L if there is any.

d)Turn on the DC switch at the bottom of the SUN2000L.

e)Perform quick setting over the FusionHomeapp. There are two methods to add the device. Method 1: tap Go to set after quick setting is

complete, and then configure parameters on the Add/Delete device 2: on the Operation consolescreen, choose Device

maintenance > Add/Delete device, and add the deviceaccording to actual conditions.

7

Model

CHINT-DDSU666

Gavazzi-EM111DINAV81XS1X

Gavazzi-EM340DINAV23XS1X

LG-RESU

Commaddress

11

1

1

15

Energy Meter Parameter

Commaddress

DescriptionValue Range

Specifies the RS485 address for the connected energy meter. The address

[1, 247]

should be the same as the actual address for the energy meter.

Specifies the model of the connected energymeter. No energymeters of

other models can be connected.

Metermodel

CHINT-DDSU666

Gavazzi-EM111DINAV81XS1X

Gavazzi-EM340DINAV23XS1X

Value RangeBattery Parameter

Commaddress

Battery type

Maximum Discharging

Power

Description

Specifies the RS485 address for the connected battery. The address should be [1, 247]

the same as the actual address for the battery.

Specifies the type of the connected battery. No batteries of other types can be

connected.

Specifies the maximum battery charging power.

The maximum charging power is limited by the maximum output power of the

SUN2000L and whether the charge/discharge powerfunction is enabled.

LG-RESU

[0, 3500]

Maximum Charging

Power

Specifies the maximum battery discharging power.

The maximum discharging power is limited by the maximum output power of

the SUN2000L and whether the charge/discharge powerfunction is

enabled.

[0, 3500]

Full Charging Capacity

Full Discharging Capacity

Specifies the battery charging cutoff capacity.

Specifies the battery discharging cutoff capacity.

[90, 100]

[12, 20]

f)(Optional) Measure the temperatures at the joints between the DC terminals and the connectors using a point-test thermometer.

NOTE

Under normal operation conditions of the SUN2000L, the temperature rise at DC connectors should remain below 30°C at all time.

g)Observe the LEDs to check the SUN2000L operating status.

8

3.2

Checking the Match between the SUN2000L and the Battery Protocol

NOTICE

The following text describes the operations on iOS screens. The operations on Android screens are the same as those on iOS screens,

except that the screens are somewhat different. The actual screens prevail.

In the iOS system, the upgrade file can be imported to the mobile phone over your mailbox. The upgrade file name extension must

be .zip. Manually select is unavailable.

In the Android system, the upgrade file can be copied to the mobile phone. The upgrade file name extension must be .zip and the file

can be stored in your required directory. Manually select is available.

the FusionHomeapp, and choose Device maintenance > Upgrade device to view the SUN2000L version. Upgrade the SUN2000L if its

version is earlier than V100R001C00SPC305.

a)Import the SUN2000L upgrade packageto the mobile phone over your mailbox, and then log in to the FusionHomeapp as installer.

b)Upgrade the SUN2000L. The SUN2000L upgrade takes about 5 minutes. When the SUN2000L is upgraded successfully, the SUN2000L

will restart. Log in again after the restart.

9

that the battery cable connection and parameter settings (Commaddr: 15, Battery type: LG-RGSU) are correct. Then in either of the

three following cases, upgrade the battery.

ch CaseRemarks

LG RESU10H:

On the FusionHomeapp, choose Device

maintenance > Upgrade device to view the

battery version.

Upgrade the LG RESU10H if DCDC Current

versionis not 7kW-V4.7.

LG RESU7H:

1

Upgrade the LG RESU7H if DCDC Current

versionis not 5kW-V4.7.

2

The battery is Offlineand not working properly.

View the battery status by choosing Device info

> Device status on the FusionHomeapp.

3

The battery status is displayed on the Device

status screen. The battery auxiliary power

indicator is on but the battery chargingand

discharging indicators are off.

Battery

auxiliary

power

indicator

Battery

charging

indicator

Battery

discharging

indicator

NOTE

In the iOS system, the upgrade file can be imported to the mobile phone over your mailbox. The upgrade file name extension must

be .zip. Manually selectis unavailable.

10

a)Import the battery upgrade packageto the mobile phone over your mailbox, and then log in to the FusionHomeapp as installer.

The upgrade package for the LG RESU10H is RESU10H_DCDC_UPGRADE_.

The upgrade package for the LG RESU7H is RESU7H_DCDC_UPGRADE_.

b)Select the upgrade package to upgrade the battery from V2.0 to V4.7. The upgrade takes about 5 minutes.

The upgrade package for the LG RESU10H is RESU10H_DCDC_UPGRADE_.

The upgrade package for the LG RESU7H is RESU7H_DCDC_UPGRADE_.

The following figure uses LG RESU10H upgrade as an example.

11

completing the upgrade, check that the battery is working properly.

3.3

Powering Off the System

off the SUN2000L:

WARNING

After the SUN2000L powers off, the remaining electricity and heat may still cause electric shocks and body burns. Therefore, puton

protective gloves and begin servicing the SUN2000L 5 minutes after the power-off.

If the SUN2000L is connected to the battery, ensure that a shutdown command is sent from the app. Power off the system after the

SUN2000L has shut down. If no shutdown command is sent from the app, the SUN2000L will shut down after the power grid is

powered off. Then, the SUN2000L will wait for 1 minute and restart (not grid-tied) to charge the battery, which poses the risk of turning

off the DC switch with power.

a)Send a shutdown command from the app. If you log in as installer, on the Operation console screen, choose Device maintenance >

Inverter ON/OFF, and perform operations as required; if you log in as user, on the main screen, choose > Setmaint> Inverter

ON/OFF, and perform operations as required.

b)

c)

d)

e)

Turn off the AC switch between the SUN2000L and the power grid.

Turn off the DC switch at the bottom of the SUN2000L.

Turn off the DC switch between the PV string and the SUN2000L if there is any.

If a battery connects to the battery port, turn off the battery switch.

(A) PV string

(D) AC switch

(G) Residential power meter

(J) Battery switch

(B) DC switch

(E)Residential power distribution unit

(H) Power grid

(K) Alarm beacon

(C) SUN2000L

(F) Energy meter

(I) Battery

(L) Residential load

off the battery pack:

WARNING

a)

b)

c)

d)

e)

Do not turn off the Auxiliary Power ON/OFF switch in normal operation mode such as charge and discharge mode.

If not using the battery pack for a long time or there is any fault on the battery pack, turn off the Circuit Breaker switch,and then turn off

the Auxiliary Power ON/OFF switch.

Remove the wiring box cover.

Turn off the battery pack by setting the Circuit Breaker switch to the OFF position.

Make sure that every indicator on the battery pack is off. It should take 60 seconds at most for the indicators to turn off.

Turn off the Auxiliary Power ON/OFF switch.

Close the wiring box cover.

Auxiliary Power ON/OFF switch Circuit Breaker switch

12

4

2067

Alarm NameAlarm SeverityPossible CauseSuggestionAlarm ID

Faulty Power

Collector

MajorCause ID = 1

In Grid Connection with Zero

Power mode, the power

collector communication is

interrupted.

In Maximum Use of Self-

Produced Power mode, the

power collector communication

is interrupted.

that the preset power

collector model is the same as the

actual model.

that the preset

communications parameters for the

power collector are the same as the

actual configurations.

that the power collector is

powered on and the RS485

communications cable is correctly

connected.

that the communications

cable and power cable between the

SUN2000L and the battery are

properly connected.

that the battery switch is

turned on properly.

off the AC output switch, DC

input switch, and battery switch, and

then turn them on after 5 minutes. If

the fault persists, contact your

dealer.

2068Abnormal

Battery

MinorCause ID = 1

The battery is faulty.

The battery communication is

interrupted.

The battery switch trips when

the SUN2000L is running.

Customer Service Contact Information

Region

Europe

Asia Pacific

Other countries

Japan and Korea

China

India

North America

Latin America

The Middle East and Africa

Japan and Korea

China

India

The United States and Canada

All countries

All countries

***************************

**********************.com

***********************

******************************

******************************

******************************

*******************************

Country

All countries

Australia

Service Support Mailbox

******************************

******************************

Huawei Technologies Co., Ltd.

Huawei Industrial Base, Bantian, Longgang

Shenzhen 518129 People's Republic of China

13

2024年10月5日发(作者:黄含莲)

Battery & Energy Meter

Quick Guide

Issue: 01

Date: 2017-12-14

Copyright © Huawei Technologies Co., Ltd. 2017. All rights reserved.

1

Preparing Cables

NOTICE

The battery output voltage

should always be lower

than or equal to 500 V DC.

NOTE

NOTE

The CAN_H and CAN_L ports of the battery are not used in this document.

This chapter describes the

CHINT-DDSU666 energy

meter. For information about

more energy meters, see

Chapter 3 Energy Meter

Cables Connection.

1.1

Preparing the Battery Cables

e the battery switch between theLG RESU7H/LG RESU10H and the SUN2000L.

Component

Battery switch

Description

Recommended: a DC circuit breaker with a rated voltage greater than

or equal to 600 V DC and a rated current of 20 A

Source

Prepared by the customer

e the power cable between theLG RESU7H/LG RESU10H and the SUN2000L.

CableLG

RESU7H/LG

RESU10H

SUN2000L

TypeConductor Cross-

sectional Area

Range

4–6 mm

2

4–6 mm

2

Outer

Diameter

N/A

4.5–7.8

mm

Source

Ground wire

Negative line of

the power cable

Positive line of the

power cable

-

+

N/A

BAT-

BAT+

Single-core outdoor

copper cable

Standard PV cable in

the industry

(recommended model:

PV1-F)

Prepared by the

customer

Prepared by the

customer

e the battery communications cable between theLG RESU7H/LG RESU10H and the SUN2000L.

Cable

Communications

cable

LG RESU7H/LG

RESU10H

2) EN GND

3)ENABLE_H

4) RS485_H

5) RS485_L

(COM)

SUN2000L

5) EN-

6) EN+

4) 485A2

3) 485B2

Type

Four-core

outdoor

shielded

twisted pair

Conductor Cross-

sectional Area Range

0.25–1 mm

2

Outer

Diameter

4–11 mm

Source

Prepared by the

customer

1

1.2

Preparing the Energy Meter Cables

e the AC switch between the energy meter and the SUN2000L.

Component

AC switch

Description

Recommended: a single-phase AC circuit breaker with a rated voltage

greater than or equal to 250 V AC and a rated current of

•16 A (SUN2000L-2KTL)

•25 A (SUN2000L-3KTL and SUN2000L-3.68KTL)

•32 A (SUN2000L-4KTL, SUN2000L-4.6KTL, and SUN2000L-5KTL)

Source

Prepared by the customer

e cables between the energy meter and the SUN2000L.

CHINT-DDSU666

CableCHINT-

DDSU666

1) L

3) N

(AC)

SUN2000L

L

N

Type

Two-core (L and N)

outdoor copper

cable

Conductor Cross-

sectional Area Range

4–6 mm

2

Outer

Diameter

10–21 mm

Source

Prepared by the

customer

AC output power

cable between the

energy meter and

the SUN2000L

Cable

Communications

cable

CHINT-

DDSU666

RS485A(+)

RS485B(-)

(COM)

SUN2000L

2) 485A1

1) 485B1

Type

Four-core outdoor

shielded twisted

pair

Conductor Cross-

sectional Area Range

0.25–1 mm

2

Outer

Diameter

4–11 mm

Source

Prepared by the

customer

EM111DINAV81XS1X

CableEM111DINA

V81XS1X

2) L

N

(AC)

SUN2000L

L

N

Type

Two-core (L and N)

outdoor copper cable

Conductor Cross-

sectional Area Range

4–6 mm

2

Outer

Diameter

10–21 mm

Source

Prepared by the

customer

AC output power

cable between the

energy meter and

the SUN2000L

Cable

Communications

cable

EM111DINAV81X

S1X

6) B+

(COM)

SUN2000L

2) 485A1

Type

Four-core

outdoor

shielded

twisted pair

Conductor Cross-

sectional Area Range

0.25–1 mm

2

Outer

Diameter

4–11 mm

Source

Prepared by the

customer

8) A-1) 485B1

EM340DINAV23XS1X

CableEM340DINA

V23XS1X

4) L

N

EM340DINAV23X

S1X

8) B+

9) A-

(AC)

SUN2000L

L

N

(COM)

SUN2000L

2) 485A1

1) 485B1

Type

Two-core (L and N)

outdoor copper

cable

Conductor Cross-

sectional Area Range

4–6 mm

2

Outer

Diameter

10–21 mm

Source

Prepared by the

customer

AC output power

cable between the

energy meter and the

SUN2000L

Cable

Communications

cable

Type

Four-core

outdoor

shielded

twisted pair

Conductor Cross-

sectional Area Range

0.25–1 mm

2

Outer

Diameter

4–11 mm

Source

Prepared by the

customer

NOTICE

If a connector needs to connect to two signal cables, ensure that the cables have the same outer diameter.

2

2

Battery Cables Connection

2.1

Connecting the Battery Cables to the Battery Pack

NOTICE

Make sure that the Auxiliary Power ON/OFF switch and the Circuit Breaker switch of the battery pack are turned off before connecting

the power cable to the battery pack.

Make sure that the inverter AC and DC disconnections are turned off before connecting the power cable to the battery pack.

t the Communications Cable.

t the power cable.

a)Connect the ground wire to terminal 1.

b)Connect the negative line of the power cable to terminal 2.

c)Connect the positive line of the power cable to terminal 3.

At first, connect the wire to terminal 2. Then, make

connections to the 3, 4, and 5 terminals one after another.

2.2

Connecting the Battery Cables to the SUN2000L

DANGER

Do not connect or disconnect battery cables when the SUN2000L is running. Failing to do so may cause electric shocks.

Before connecting battery cables, ensure that the DC switch on the SUN2000L and all the switches connecting to the SUN2000L are OFF,

and the SUN2000L has no residual electricity. Otherwise, the high voltage of the SUN2000L and battery may result in electric shocks.

If no battery connects to the SUN2000L, do not remove the watertight cap from the battery terminal. Otherwise, the SUN2000L willnot

comply with its Ingress Protection Rating. If a battery connects to the SUN2000L, set aside the watertight cap. Reinstall thewatertight cap

immediately after removing the connector. The high voltage of the battery terminal may result in electric shocks.

le the blue positive and negative connectors, and then connect the power cable.

Positive metal terminal

Positive connector

Ensure that

the locking nut

is secured.

Negative metal terminal

Ensure that the cable will not

be extracted after crimped.

Negative connector

Pull the power cable back to ensure that it

is connected securely.

Click

Savethe watertight

caps for later use.

Pull the battery cable back to ensure

that it is connected securely.

WARNING

Do not connect any load between the SUN2000L and the battery.

Ensure that the following conditions are met. Otherwise, the SUN2000L will be damaged, or even become a fire hazard.

The battery cable is connected correctly. That is, the positive and negative terminals of the battery connect to the positive battery terminal

and negative battery terminal on the SUN2000L respectively.

The cable between the battery and the SUN2000L should be less than or equal to 10 meters, and within 5 meters is recommended.

The battery voltage can result in fatal injury. Use dedicated insulation tools to terminate cables.

Ensure that the battery cable is correctly connected. Avoid reverse polarity.

3

t the communications cable.

No.

3

4

LabelDefinition

RS485B, RS485

485B2

differential signal–

485A2

RS485A, RS485

differential signal+

NOTICE

5

6

8

EN–

EN+

PE

Enable signal–

Enable signal+

Grounding the shield layer

When laying out signal cables, separate

them from power cables to avoid strong

signal interference sources.

The protection layer of the signal cable is

in the connector. Surplus core wires are

cut off from the protection layer. The

exposed core wire is totally inserted into

the cable hole and connected securely.

3

a)

3.1

Connecting the Energy Meter Cables to the SUN2000L

t the AC output power cable to the SUN2000L.

Connect the AC output power cable to the AC connector.

Energy Meter Cables Connection

Connection

Click

b)Connect the AC connector to the AC output port.

c)Check the route of the AC

output power cable.

t the communications cable to the SUN2000L.

4

3.2

Connecting the Energy Meter Cables to the Energy Meter

CHINT-DDSU666

Open the front cover, and then connect the cable to the CHINT-DDSU666.

Top view

4) N

8) RS485B

7) RS485A

3) N

SUN2000L

7) 485A

8) 485B

3) N4) N

COM

1) 485B1

2) 485A1

AC

LN

Power grid

Side view

Front cover

AC

switch

CHINT-DDSU666

1) L

2) L

Front cover

L

Bottom view

1) L

5) P+

6) PQ-

2) L

NL

Load

NOTE

The P+ and PQ+ ports are not used in this document.

It is recommended that the energy meter be installed in the original residential power

distribution unit. The energy meter can also be independently installed outside the original

residential power distribution unit.

EM111DINAV81XS1X

Open the front cover, and then connect the cable to the EM111DINAV81XS1X.

LL

SUN2000L

COM

2) 485A11) 485B1

AC

LN

B+

Power grid

A-

AC

switch

Residential power

distribution unit

NOTE

It is recommended that the energy meter be installed in

the original residential power distribution unit. The

energy meter can also be independently installed

outside the original residential power distribution unit.

NL

Load

5

EM340DINAV23XS1X

Open the front cover, and then connect the cable to the EM340DINAV23XS1X.

L1L2L3

COM

2) 485A11) 485B1

AC

L

N

EM340DINAV23XS1X

AC

switch

B+

A-

Power grid

L1L2L3

NOTE

It is recommended that the energy meter be

installed in the original residential power

distribution unit. The energy meter can also be

independently installed outside the original

residential power distribution unit.

NL1L2L3

Residential power

distribution unit

Load

3

Commissioning

3.1

Powering On the System

the battery pack in operation by taking the following steps:

a)Turn on the Auxiliary Power ON/OFF switch after installing the battery pack. Make sure that the Circuit Breaker switch is in theOFF

position (including the Trip position).

b)Set the Circuit Breaker switch to the ON position.

Auxiliary Power ON/OFF switch Circuit Breaker switch

c)Several seconds after the Circuit Breaker switch is set to ON, 4 LEDs will be lit.

d)Make sure that ON indicator is on and see if the battery pack is successfully initialized. The power-on indicator on the front should turn on

in green.

e)Close the wiring box cover.

6

on the SUN2000L:

NOTICE

.

Before turning on the AC switch between the SUN2000L and the power grid, check that the AC voltage on the power grid side of the AC

switch is within the specified range.

If the DC is on and the AC is off, the SUN2000L reports a Grid Failurealarm. The SUN2000L starts normally only after the fault is rectified.

If the AC is on and the battery is off, the SUN2000L reports a Battery Abnormal alarm.

(A) PV string

(D) AC switch

(G) Residential power meter

(J) Battery switch

(B) DC switch

(E)Residential power distribution unit

(H) Power grid

(K) Alarm beacon

(C) SUN2000L

(F) Energy meter

(I) Battery

(L) Residential load

a)Turn on the battery switch between the battery pack and the SUN2000L.

b)Turn on the AC switchbetween the SUN2000L and the power grid.

NOTICE

If the SUN2000L is connected to the battery, after turning on the AC switch:

If the DC switch is turned on within 1 minute, the SUN2000L will run properly in grid-tied mode.

If the DC switch is not turned on within 1 minute, the SUN2000L will enter the nighttime grid-tied mode. Then, after the DC switch is

turned on, the SUN2000L will shut down and then restart to run in grid-tied mode.

c)Turn on the DC switch between the PV string and the SUN2000L if there is any.

d)Turn on the DC switch at the bottom of the SUN2000L.

e)Perform quick setting over the FusionHomeapp. There are two methods to add the device. Method 1: tap Go to set after quick setting is

complete, and then configure parameters on the Add/Delete device 2: on the Operation consolescreen, choose Device

maintenance > Add/Delete device, and add the deviceaccording to actual conditions.

7

Model

CHINT-DDSU666

Gavazzi-EM111DINAV81XS1X

Gavazzi-EM340DINAV23XS1X

LG-RESU

Commaddress

11

1

1

15

Energy Meter Parameter

Commaddress

DescriptionValue Range

Specifies the RS485 address for the connected energy meter. The address

[1, 247]

should be the same as the actual address for the energy meter.

Specifies the model of the connected energymeter. No energymeters of

other models can be connected.

Metermodel

CHINT-DDSU666

Gavazzi-EM111DINAV81XS1X

Gavazzi-EM340DINAV23XS1X

Value RangeBattery Parameter

Commaddress

Battery type

Maximum Discharging

Power

Description

Specifies the RS485 address for the connected battery. The address should be [1, 247]

the same as the actual address for the battery.

Specifies the type of the connected battery. No batteries of other types can be

connected.

Specifies the maximum battery charging power.

The maximum charging power is limited by the maximum output power of the

SUN2000L and whether the charge/discharge powerfunction is enabled.

LG-RESU

[0, 3500]

Maximum Charging

Power

Specifies the maximum battery discharging power.

The maximum discharging power is limited by the maximum output power of

the SUN2000L and whether the charge/discharge powerfunction is

enabled.

[0, 3500]

Full Charging Capacity

Full Discharging Capacity

Specifies the battery charging cutoff capacity.

Specifies the battery discharging cutoff capacity.

[90, 100]

[12, 20]

f)(Optional) Measure the temperatures at the joints between the DC terminals and the connectors using a point-test thermometer.

NOTE

Under normal operation conditions of the SUN2000L, the temperature rise at DC connectors should remain below 30°C at all time.

g)Observe the LEDs to check the SUN2000L operating status.

8

3.2

Checking the Match between the SUN2000L and the Battery Protocol

NOTICE

The following text describes the operations on iOS screens. The operations on Android screens are the same as those on iOS screens,

except that the screens are somewhat different. The actual screens prevail.

In the iOS system, the upgrade file can be imported to the mobile phone over your mailbox. The upgrade file name extension must

be .zip. Manually select is unavailable.

In the Android system, the upgrade file can be copied to the mobile phone. The upgrade file name extension must be .zip and the file

can be stored in your required directory. Manually select is available.

the FusionHomeapp, and choose Device maintenance > Upgrade device to view the SUN2000L version. Upgrade the SUN2000L if its

version is earlier than V100R001C00SPC305.

a)Import the SUN2000L upgrade packageto the mobile phone over your mailbox, and then log in to the FusionHomeapp as installer.

b)Upgrade the SUN2000L. The SUN2000L upgrade takes about 5 minutes. When the SUN2000L is upgraded successfully, the SUN2000L

will restart. Log in again after the restart.

9

that the battery cable connection and parameter settings (Commaddr: 15, Battery type: LG-RGSU) are correct. Then in either of the

three following cases, upgrade the battery.

ch CaseRemarks

LG RESU10H:

On the FusionHomeapp, choose Device

maintenance > Upgrade device to view the

battery version.

Upgrade the LG RESU10H if DCDC Current

versionis not 7kW-V4.7.

LG RESU7H:

1

Upgrade the LG RESU7H if DCDC Current

versionis not 5kW-V4.7.

2

The battery is Offlineand not working properly.

View the battery status by choosing Device info

> Device status on the FusionHomeapp.

3

The battery status is displayed on the Device

status screen. The battery auxiliary power

indicator is on but the battery chargingand

discharging indicators are off.

Battery

auxiliary

power

indicator

Battery

charging

indicator

Battery

discharging

indicator

NOTE

In the iOS system, the upgrade file can be imported to the mobile phone over your mailbox. The upgrade file name extension must

be .zip. Manually selectis unavailable.

10

a)Import the battery upgrade packageto the mobile phone over your mailbox, and then log in to the FusionHomeapp as installer.

The upgrade package for the LG RESU10H is RESU10H_DCDC_UPGRADE_.

The upgrade package for the LG RESU7H is RESU7H_DCDC_UPGRADE_.

b)Select the upgrade package to upgrade the battery from V2.0 to V4.7. The upgrade takes about 5 minutes.

The upgrade package for the LG RESU10H is RESU10H_DCDC_UPGRADE_.

The upgrade package for the LG RESU7H is RESU7H_DCDC_UPGRADE_.

The following figure uses LG RESU10H upgrade as an example.

11

completing the upgrade, check that the battery is working properly.

3.3

Powering Off the System

off the SUN2000L:

WARNING

After the SUN2000L powers off, the remaining electricity and heat may still cause electric shocks and body burns. Therefore, puton

protective gloves and begin servicing the SUN2000L 5 minutes after the power-off.

If the SUN2000L is connected to the battery, ensure that a shutdown command is sent from the app. Power off the system after the

SUN2000L has shut down. If no shutdown command is sent from the app, the SUN2000L will shut down after the power grid is

powered off. Then, the SUN2000L will wait for 1 minute and restart (not grid-tied) to charge the battery, which poses the risk of turning

off the DC switch with power.

a)Send a shutdown command from the app. If you log in as installer, on the Operation console screen, choose Device maintenance >

Inverter ON/OFF, and perform operations as required; if you log in as user, on the main screen, choose > Setmaint> Inverter

ON/OFF, and perform operations as required.

b)

c)

d)

e)

Turn off the AC switch between the SUN2000L and the power grid.

Turn off the DC switch at the bottom of the SUN2000L.

Turn off the DC switch between the PV string and the SUN2000L if there is any.

If a battery connects to the battery port, turn off the battery switch.

(A) PV string

(D) AC switch

(G) Residential power meter

(J) Battery switch

(B) DC switch

(E)Residential power distribution unit

(H) Power grid

(K) Alarm beacon

(C) SUN2000L

(F) Energy meter

(I) Battery

(L) Residential load

off the battery pack:

WARNING

a)

b)

c)

d)

e)

Do not turn off the Auxiliary Power ON/OFF switch in normal operation mode such as charge and discharge mode.

If not using the battery pack for a long time or there is any fault on the battery pack, turn off the Circuit Breaker switch,and then turn off

the Auxiliary Power ON/OFF switch.

Remove the wiring box cover.

Turn off the battery pack by setting the Circuit Breaker switch to the OFF position.

Make sure that every indicator on the battery pack is off. It should take 60 seconds at most for the indicators to turn off.

Turn off the Auxiliary Power ON/OFF switch.

Close the wiring box cover.

Auxiliary Power ON/OFF switch Circuit Breaker switch

12

4

2067

Alarm NameAlarm SeverityPossible CauseSuggestionAlarm ID

Faulty Power

Collector

MajorCause ID = 1

In Grid Connection with Zero

Power mode, the power

collector communication is

interrupted.

In Maximum Use of Self-

Produced Power mode, the

power collector communication

is interrupted.

that the preset power

collector model is the same as the

actual model.

that the preset

communications parameters for the

power collector are the same as the

actual configurations.

that the power collector is

powered on and the RS485

communications cable is correctly

connected.

that the communications

cable and power cable between the

SUN2000L and the battery are

properly connected.

that the battery switch is

turned on properly.

off the AC output switch, DC

input switch, and battery switch, and

then turn them on after 5 minutes. If

the fault persists, contact your

dealer.

2068Abnormal

Battery

MinorCause ID = 1

The battery is faulty.

The battery communication is

interrupted.

The battery switch trips when

the SUN2000L is running.

Customer Service Contact Information

Region

Europe

Asia Pacific

Other countries

Japan and Korea

China

India

North America

Latin America

The Middle East and Africa

Japan and Korea

China

India

The United States and Canada

All countries

All countries

***************************

**********************.com

***********************

******************************

******************************

******************************

*******************************

Country

All countries

Australia

Service Support Mailbox

******************************

******************************

Huawei Technologies Co., Ltd.

Huawei Industrial Base, Bantian, Longgang

Shenzhen 518129 People's Republic of China

13

发布评论

评论列表 (0)

  1. 暂无评论