最新消息: USBMI致力于为网友们分享Windows、安卓、IOS等主流手机系统相关的资讯以及评测、同时提供相关教程、应用、软件下载等服务。

三星三元电芯规格书

IT圈 admin 46浏览 0评论

2023年12月6日发(作者:黎飞兰)

-SAMSUNG SDI Confidential Proprietary –

Spec. No.

ICP663450A Version No. 0.0

SPECIFICATION OF PRODUCT

SPECIFICATION OF PRODUCT

for Lithium-ion Rechargeable Cell

Model : ICP663450A

Fed. 8th, 2007

Samsung SDI Co.,Ltd.

Battery Division -SAMSUNG SDI Confidential Proprietary –

Spec. No.

ICP663450A Version No. 0.0

SPECIFICATIONS

1. Scope

This product specification has been prepared to specify the rechargeable lithium-ion cell

('cell') to be supplied to the customer by Samsung SDI Co., Ltd.

2. Description and Model

2.1 Description Cell (lithium-ion rechargeable cell)

2.2 Model ICP663450A

3. Nominal Specifications

Item

3.1 Nominal Capacity

3.2 Charging Voltage

3.3 Nominal Voltage

3.4 Charging Method

3.5 Charging Current

3.6 Charging Time

3.7 Max. Charge Current

3.8 Max. Discharge Current

3.9 Discharge Cut-off Voltage

3.10 Cell Weight

3.11 Cell Dimension

3.12 Operating Temperature

3.13 Storage Temperature

Note (1): If the cell is kept as ex-factory status (50~60% of Charge state),

the capacity recovery rate is more than 80%.

Specification

1330mAh (0.2C discharge)

4.2V

3.7V

CC-CV (constant voltage with limited current)

Standard charge: 665mA

Rapid charge: 1330mA

Standard charge: 3hours

Rapid charge: 2.5hours

1330mA

2660mA

2.75V

Max. 28.0g

Thickness: Max. 6.60mm (Initial fully charged cell)

Width: Max. 34.0mm

Height: Max. 50.0mm

Charge : 0 to 45℃

Discharge: –20 to 60℃

1 year : -20~25℃(1*)

3 months : -20~45℃(1*)

1 month : -20~60℃(1*)

1

Battery Division -SAMSUNG SDI Confidential Proprietary –

Spec. No.

ICP663450A Version No. 0.0

4. Outline Dimensions

See the attachment (Fig. 1)

5. Appearance

There shall be no such defects as scratch, rust, discoloration, leakage which

may adversely affect commercial value of the cell.

6. Standard Test Conditions

6.1 Environmental Conditions

Unless otherwise specified, all tests stated in this specification are conducted

at temperature 25±3℃ and humidity 65±20%.

6.2 Measuring Equipment

(1) Ammeter and Voltmeter

The ammeter and voltmeter should have an accuracy of the grade 0.5 or higher.

(2) Slide caliper

The slide caliper should have 0.05 mm scale.

(3) Impedance meter

The impedance meter with AC 1kHz should be used.

7. Characteristics

7.1 Standard Charge

This "Standard Charge" means charging the cell with charge current 665mA

and constant voltage 4.2V at 25℃ for 3hours.

7.2 Rated Charge

This "Rated Charge" means charging the cell with charge current 650mA

and constant voltage 4.2V and 0.05C(=65mA) cut-off at 25℃.

7.3 Standard Discharge Capacity

The standard discharge capacity is the initial discharge capacity of the cell, which is

measured with discharge current of 266mA with 2.75V cut-off at 25℃ within 1 hour

after the standard charge.

Standard Discharge Capacity

≥ 1330mAh

7.4 Rated Discharge Capacity

The rated discharge capacity is the initial discharge capacity of the cell, which is

measured with discharge current of 650mA with 3.2V cut-off at 25℃ within 1 hour

after the rated charge.

Rated Discharge Capacity

≥ 650mAh

2

Battery Division -SAMSUNG SDI Confidential Proprietary –

Spec. No.

ICP663450A Version No. 0.0

7.5 Pulse Discharge

Cell shall be discharged at a constant current rate of 1C to 3.2V.

Cells shall be also discharged per the pulse profile described figure.1 until 3.2V.

Figure 1. Pulse Profile

1.5A80mA0.6ms

4ms

7.6 Initial internal impedance

Initial internal impedance measured at AC 1kHz after rated charge.

Initial internal impedance range of 45

± 15mΩ

7.7 Charge Rate Capabilities

Discharge capacity is measured with constant current 650mA and 3.2V cut-off

after the cell is charged with 4.2V as follows.

Current

Cut-off

0.2C

(260mA)

0.05C

Charge Condition

0.5C

(650mA)

0.05C

1.0C

(1300mA)

0.05C

2.0C

(2600mA)

0.05C

Relative

100% 100% 100% 90%

Capacity

Note: Percentage as an index of the rated discharge capacity (=1300mAh) is 100%.

7.8 Discharge Rate Capabilities

Discharge capacity is measured with the various currents in under table and 3.2V

cut-off after the rated charge.

3

Battery Division -SAMSUNG SDI Confidential Proprietary –

Spec. No.

ICP663450A Version No. 0.0

Current

Relative

Capacity

0.2C

(260mA)

102%

Discharge Condition

0.5C

(650mA)

100%

1.0C

(650mA)

95%

2.0C

(2600mA)

80%

Pulse

100%

Note: Percentage as an index of the rated discharge capacity (=1300mAh) is 100%.

7.9 Temperature Dependence of Discharge Capacity

Capacity comparison at each temperature, measured with discharge

constant current 650mA and 3.2V cut-off after the rated charge is as follows.

Charge Temperature

25℃

Relative Capacity

-20℃

5%

Discharge temperature (0.5C)

-10℃

40%

0℃

80%

25℃

100%

40℃

100%

60℃

90%

Note: If charge temperature and discharge temperature is not the same,

the interval for temperature change is 2 hours.

Percentage as an index of the rated discharge capacity (=1300mAh) is 100%.

Charge Temperature

25℃

Relative Capacity

-20℃

5%

Discharge temperature (Pulse)

-10℃

40%

0℃

80%

25℃

100%

40℃

100%

60℃

90%

7.10 Temperature Dependence of Charge Capacity

Capacity comparison at each temperature, measured with discharge

constant current 650mA and 3.2V cut-off after the rated charge is as follows.

Relative Capacity

Charge temperature

0℃

80%

25℃

100%

40℃

100%

Discharge temperature

25℃

Note: If charge temperature and discharge temperature is not the same,

the interval for temperature change is 2 hours.

Percentage as an index of the rated discharge capacity (=1300mAh) is 100%.

7.10 Cycle Life

Each cycle is an interval between the charge (charge current 1300mA) with

0.05C cut-off and the discharge (discharge current 1300mA) with 3.2V cut-off.

4

Battery Division -SAMSUNG SDI Confidential Proprietary –

Spec. No.

ICP663450A Version No. 0.0

Capacity is measured at 100cycles,300cycles and 500cycles.

100cyc. Capacity

≥ 1170mAh (90% of the rated discharge capacity)

300cyc. Capacity

≥ 1105mAh (85% of the rated discharge capacity)

500cyc. Capacity

≥ 1040mAh (80% of the rated discharge capacity)

7.11 Storage Characteristics

Capacity after storage for 30days at 25℃ after the rated charged measured with

discharge current 650mA with 3.2V cut-off at 25℃.

Capacity retention(after the storage)

≥ 1235mAh (95% of the rated discharge capacity)

8. Mechanical Characteristics

8.1 Drop Test

Test method: Cell(rated charged) is dropped onto the steel plate (thickness≥10mm)

from 1.5m height at each side 3 times and a random direction 2 times.

(Total 20 times)

Criteria: No leakage, Open circuit voltage

≥ 4.0V, IR < 100mΩ

8.2 Vibration Test

Test method: Cell(rated charged) is vibrated only up and down direction

with vibration cycling that consists of 10Hz to 500Hz and 500Hz to 1800Hz

during 45min per each mode (ASD: 0.1g2/Hz, Average Acceleration:

6gRMS) at 25℃±3℃.

Criteria: No leakage, Open circuit voltage

≥ 4.0V, IR < 100mΩ

9. Environmental Characteristics

9.1 Thermal Shock

Test method: Cell(rated charged) is repeatedly tested with 30 times heat cycling, which

means maintaining the cell for 1hours at –40℃ and 85℃ respectively.

Inspect its appearance and measure its thickness right after thermal shock.

Measure the recovered capacity by rated charge/discharge cycling after

rated discharging(650mA, 3.2V cut-off) at 25℃.

Criteria: No leakage, Cell thickness < 7.26mm

Recovery > 1040mAh (80% of the rated discharge capacity)

9.2 Humidity

Test method: Cell(rated charged) is exposed to 50℃,95%RH. for 10days

5

Battery Division -SAMSUNG SDI Confidential Proprietary –

Spec. No.

ICP663450A Version No. 0.0

Inspect appearance and measure thickness right after humidity test.

Measure the recovered capacity by rated charge/discharge cycling after

rated discharging(650mA, 3.2V cut-off) at 25℃.

Criteria: No leakage, Cell thickness < 6.93mm,

Recovery > 1170mAh (90% of the rated discharge capacity)

9.3 Life cycle at low temperature

Repeat 10times of cycles(Discharging first) at 0℃(Charge :1C,4.2V,0.05C cut off,

Discharge: 1C, 3.2V), and measure IR & thickness after 5ycles and 10cycles, after

cycling test, measure the IR & thickness after stand 2hours at 25±3℃.

Criteria: 10cyc. Thickness < 6.93mm

9.4 Low Pressure

Cell(rated charged) is deposited into the vacuum chamber in pressure 11.6kPa for

6hours at 25±3℃, inspect appearance and measure the IR & voltage after test

Criteria: No leakage, Open circuit voltage

≥ 4.0V, IR < 100mΩ

9.5 Abnormal charge

Test method: To charge the rate charged cell to 4.25V, 4.275V and 4.30V and with

constant current of 700mA for 168hours at 25℃.

Criteria: Thickness < 7.10mm

10. Safety

Safety Test shall be performed with the following criteria

- UL1642

- Fully Charged Cell

- No protection component/circuit on the battery cell, i.e. bare cell.

Testing shall be performed at 25℃±3℃.

There should be neither fire nor explosion after testing under the temperature of 200℃.

10.1 Overcharge Test (without PTC)

Test method: To charge the standard charged cell with 5V and 1.0A at 25℃

for 2.5 hours.

Criteria: No fire, and no explosion.

6

Battery Division -SAMSUNG SDI Confidential Proprietary –

Spec. No.

ICP663450A Version No. 0.0

10.2 External Short-circuit Test

Test method: The cell shall be fully charged, it is stored in ambient temperature of 60℃.

Each test sample is short-circuited by connecting positive and negative

terminal with less than 100mΩ wire. And stand for 2.5 hours

Criteria: No smoke, No fire, and no explosion.

10.3 Reverse Charge Test

Test method: To charge reverse the standard charged cell with charge current 1330mA

for 2.5 hours.

Criteria: No fire, and no explosion.

10.4 Nail Penetrating Test

Test method: Cell shall be fully charged. Penetrate completely center of cell with

5mm diameter nail at the velocity of 40mm/sec.

Criteria: No fire, and no explosion.

10.5 Heating Test

Test method: To heat the standard charged cell at heating rate 5℃ per minute up to

150℃ and keep the cell in oven for 60 minutes.

Criteria: No fire, and no explosion within 10min.

10.6 Crush

Test method: To crush the standard charged cell with force of 13kN.

(Crushed side is longitudinal and narrow axis.)

Criteria: No fire, and no explosion.

10.7 Impact

Test method: To place 15.8mm diameter bar across the center of standard charged cell,

and drop 9.1kg weight from 610±25mm height onto the cell.

(Impacted side is longitudinal and wide axis.)

Criteria: No fire, and no explosion.

7

Battery Division -SAMSUNG SDI Confidential Proprietary –

Spec. No.

ICP663450A Version No. 0.0

11. Warranty

Samsung SDI will be responsible for replacing the cell against defects or poor workmanship

for 1year from the date of shipping. Any other problem caused by malfunction of the

equipment or unsuitable use of the cell is not under this warranty.

The warranty set forth in proper using and handling conditions described above and

excludes in the case of a defect which is not related to manufacturing of the cell.

[ Disclaimer ]

This Specification stipulates the final and comprehensive requirements for the respective

products hereof. beyond this Specification, it is the responsibility of the customer to

explicitly disclose any additional requirements, information or reservations regarding these

requirements to Samsung SDI prior to implementation,

where any and all disclosures of the customer shall be with an authorized representative of

Samsung SDI in writing.

Samsung SDI shall not be responsible for safety, performance, functionality or compatibility

of the system with which the Samsung SDI-supplied components are integrated unless

such features have been expressly communicated and described in the Specification.

SAMSUNG SDI MAKES NO GUARANTY OR WARRANTY, EXPRESS OR IMPLIED,

INCLUDING BUT NOT LIMITED TO MERCHANTABILITY OR FITNESS FOR A

PARTICULAR PURPOSE, TO ANY PARTY.

Moreover, any party should do their own due diligence regarding these requirements prior

to implementation.

12. Others

12.1 Storage for a long time

If the cell is kept for a long time(3months or more), It is strongly recommended

that the cell is preserved at dry and low-temperature.

12.2 PTC (Positive Temperature Coefficient)

The recommended PTC model : RayChem(Japan), VTP175LF MXP190S, and

Polytronics (Japan), SLD190VF

The max. discharge current of cell with PTC depends on temperature.

12.3 Other

Any matters that specifications does not have, should be conferred with

between the both parties.

8

Battery Division -SAMSUNG SDI Confidential Proprietary –

Spec. No.

ICP663450A Version No. 0.0

Fig.1. ICP663450A

EX-Factory status 6.35mm +0/-0.3

Initial Full Charge status Max 6.60mm

9

Battery Division -SAMSUNG SDI Confidential Proprietary –

Spec. No.

ICP663450A Version No. 0.0

Proper Use and Handling of Lithium Ion Cells

See before using lithium-ion cell

Supplied by Samsung SDI Co., Ltd.

1. General

This document has been prepared to describe the appropriate cautions and

prohibitions, which the customer should take or employ when the customer uses

and handles the lithium ion cell to be manufactured and supplied by Samsung SDI Co.,

Ltd., in order to obtain optimum performance and safety.

2. Charging

2.1 Charging current

Charging current should be less than maximum charge current specified in the product

specification.

2.2 Charging voltage

Charging should be done by voltage less than that specified in the product specification.

2.3 Charging time

Continuous charging under appropriate voltage does not cause any loss of

characteristics. However, the charge timer is recommended to be installed from a safety

consideration, which shuts off further charging at time specified in the product

specification.

2.4 Charging temperature

The cell should be charged within a range of specified temperatures in the product

specification.

2.5 Reverse charging

The cell should be connected, confirming that its poles are correctly aligned.

Inverse charging should be strictly prohibited. If the cell is connected improperly,

it may be damaged.

3. Discharging

3.1 Discharging

3.1.1 The cell should be discharged at less than maximum discharge current

specified in the product specification.

10

Battery Division -SAMSUNG SDI Confidential Proprietary –

Spec. No.

ICP663450A Version No. 0.0

3.2 Discharging temperature

3.2.1 The cell should be discharged within a range of temperatures specified in

the product specification.

3.2.2 Otherwise, it may cause loss of characteristics.

3.3 Over-discharging

3.3.1 The system should equip with a device to prevent further discharging

exceeding discharging cut-off voltage specified in the product

specification.(over-discharging)

3.3.2 Over-discharging may cause loss of performance, characteristics, of

battery function.

3.3.3 Over-discharging may occur by self-discharge if the battery is left for

a very long time without any use.

3.3.4 The charger should equip with a device to detect cell voltage and to

determine recharging procedures.

4. Storage

4.1 Storage conditions

4.1.1 The cell should be stored within a range of temperatures specified

in the product specification.

4.1.2 Otherwise, it may cause loss of characteristics, leakage and/or rust.

4.2 Long-term storage

4.2.1 The cell should be used within a short period after charging because

long-term storage may cause loss of capacity by self-discharging.

4.2.2. If long-term storage is necessary, the cell should be stored at lower

voltage within a range specified in the product specification, because

storage at higher voltage may cause loss of characteristics.

5. Cycle life

5.1 Cycle life performance

5.1.1 The cell can be charged/discharged repeatedly up to times specified in

the produce specification with a certain level of capacity also specified

in the product specification.

5.1.2 Cycle life may be determined by conditions of charging, discharging,

operating temperature and/or storage.

11

Battery Division -SAMSUNG SDI Confidential Proprietary –

Spec. No.

ICP663450A Version No. 0.0

6. Design of System

6.1 Connection between the cell and the battery

6.1.1 The cell should not be soldered directly with leads. Namely, the cell

should be welded with leads on its terminal and then be soldered with

wire or leads to soldered lead.

6.1.2 Otherwise, it may cause damage of component, such as separator and

insulator, by heat generation.

6.2 Positioning the battery in the System

6.2.1 The battery should be positioned as possible as far from heat sources

and high temperature components.

6.2.2 Otherwise, it may cause loss of characteristics.

6.3 Mechanical shock protection of the battery

6.3.1 The battery should equip with appropriate shock absorbers in order to

minimize shock.

6.3.2 Otherwise, it may cause shape distortion, leakage, heat generation

and/or rupture.

6.4 Short-circuit protection of the cell

6.4.1 The cell equips with an insulating sleeve to protect short-circuit which

may occur during transportation, battery assembly and /or system

operation.

6.4.2 If the cell sleeve is damaged by some cause such as outside impact,

it may cause short-circuit with some wiring inside the battery.

6.5 Connection between the battery and charger/system

6.5.1 The battery should be designed to be connected only to the specified

charger and system.

6.5.2 A reverse connection of the battery, even in the specified system,

should be avoided by employing special battery design such as

a special terminals.

7. Battery Pack Assembly

7.1 Prohibition of usage of damaged cell

7.1.1 The cell should be inspected visually before battery assembly.

7.1.2 The cell should not be used if sleeve-damage, can-distortion and/or

electrolyte-smell is detected.

12

Battery Division -SAMSUNG SDI Confidential Proprietary –

Spec. No.

ICP663450A Version No. 0.0

7.2 Terminals handling

7.2.1 Excessive force on the negative terminal should be avoided when

external lead is welled.

7.3 Transportation

7.3.1 If the cell is necessary to transported to order place, such as the

battery manufacturer, careful precautions should be taken to avoid

damage of cell.

8. Others

8.1 Disassembly

8.1.1 The cell should not be dismantled from the battery pack.

8.1.2 Internal short-circuit caused by disassembly may lead to heat generation

and/or venting.

8.1.3 When the electrolyte is coming in contact with the skin or eyes,

flush immediately with fresh water and seek medical advice.

8.2 Short-circuiting

8.2.1 Short-circuit results in very high current which leads to heat generation.

8.2.3 An appropriate circuitry should be employed to protect accidental

short-circuiting.

8.3 Incineration

8.3.1 Incinerating and disposing of the cell in fire are strictly prohibited,

because it may cause rupture.

8.4 Immersion

8.4.1 Soaking the cell in water is strictly prohibited, because it may cause

melt of components to damaged to functions.

8.5 Mixing use

8.5.1 Different types of cell, or same types but different manufacturer's cell

may lead to cell rupture or damage to system due to the different

characteristics of cell.

8.6 Battery exchange

8.6.1 Although the cell contains no environmentally hazardous component,

such as lead or cadmium. the battery should be disposed according to

the local regulations when it is disposed.

13

Battery Division -SAMSUNG SDI Confidential Proprietary –

Spec. No.

ICP663450A Version No. 0.0

8.6.2 The cell should be disposed with a discharged state to avoid heat generation

by an inadvertent short-circuit.

8.7 Caution

"The Battery used in this device may present a risk of fire or chemical burn if mistreated.

Do not disassemble, heat above 100℃ or incinerate. Replace battery with Samsung

SDI battery only. Use of another battery may present a risk of fire or explosion.

Dispose of used battery promptly. Keep away from children. Do not disassemble and do

not dispose of in fire."

14

Battery Division -SAMSUNG SDI Confidential Proprietary –

Spec. No.

8.8 Warning

ICP663450A Version No. 0.0

Handling Precaution and Prohibitions of Lithium Ion & Lithium Ion Polymer

Rechargeable Cells and Batteries

Inaccurate handling of lithium ion and lithium ion polymer rechargeable battery may cause leakage, heat,

smoke, an explosion, or fire.

This could cause deterioration of performance or failure. Please be sure to follow instructions carefully.

1.1 Storage

Store the battery at low temperature (below 20℃ is recommended), low humidity, no dust and no

corrosive gas atmosphere.

1.2 Safety precaution and prohibitions

To assure product safety, describe the following precautions in the instruction manual of the

application.

[ Danger!]

■ Electrical misusage

Use dedicated charger.

Use or charge the battery only in the dedicated application.

Don't charge the battery by an electric outlet directly or a cigarette lighter charger.

Don't charge the battery reversely.

■ Environmental misusage

Don't leave the battery near the fire or a heated source.

Don't throw the battery into the fire.

Don't leave, charge or use the battery in a car or similar place where inside of temperature may be

over 60℃.

Don't immerse, throw, wet the battery in water / seawater.

■ others

Don't fold the battery cased with laminated film such as pouch and Polymer.

Don't store the battery in a pocket or a bag together with metallic objects such as keys, necklaces,

hairpins, coins, or screws.

Don't short circuit (+) and (-) terminals with metallic object intentionally.

Don't pierce the battery with a sharp object such as a needle, screw drivers.

Don't heat partial area of the battery with heated objects such as soldering iron.

Don't hit with heavy objects such as a hammer, weight.

Don't step on the battery and throw or drop the battery on the hard floor to avoid mechanical shock.

15

Battery Division -SAMSUNG SDI Confidential Proprietary –

Spec. No.

ICP663450A Version No. 0.0

Don't disassemble the battery or modify the battery design including electric circuit.

Don't solder on the battery directly.

Don't use seriously scared or deformed battery.

Don't put the battery into a microwave oven, dryer ,or high-pressure container.

Don't use or assemble the battery with other makers' batteries, different types and/or models of

batteries such as dry batteries, nickel-metal hydride batteries, or nickel-cadmium batteries.

Don't use or assemble old and new batteries together.

[ Warning! ]

Stop charging the battery if charging isn't completed within the specified time.

Stop using the battery if the battery becomes abnormally hot, order, discoloration, deformation, or

abnormal conditions is detected during use, charge, or storage.

Keep away from fire immediately when leakage or foul odors are detected. If liquid leaks onto your

skin or cloths, wash well with fresh water immediately.

If liquid leaking from the battery gets into your eyes, don't rub your eyes and wash them with clean

water and go to see a doctor immediately.

If the terminals of the battery become dirty, wipe with a dry cloth before using the battery.

The battery can be used within the following temperature ranges. Don't exceed these ranges.

Charge temperature ranges : 0℃ ~ 45℃

Discharge Temperature ranges : -20℃ ~ 60℃

Store the battery at temperature below 60℃

Cover terminals with proper insulating tape before disposal.

[ Caution! ]

■ Electrical misusage

Battery must be charge with constant current-constant voltage (CC/CV).

Charge current must be controlled by specified value in Cell specification.

Cut-off Voltage of charging must be 4.2V.

Charger must stop charging battery by detecting either charging time or current specified in Cell’s

specification.

Discharge current must be controlled by specified value in Cell’s specification.

Cut-off Voltage of discharging must be over 2.5V.

16

Battery Division -SAMSUNG SDI Confidential Proprietary –

Spec. No.

■ others

ICP663450A Version No. 0.0

Keep the battery away from babies and children to avoid any accidents such as swallow.

If younger children use the battery, their guardians should explain the proper handling method and

precaution before using.

Before using the battery, be sure to read the user's manual and precaution of it's handling.

Before using charger, be sure to read the user's manual of the charger.

Before installing and removing the battery from application, be sure to read user's manual of the

application.

Replace the battery when using time of battery becomes much shorter than usual.

Cover terminals with insulating tape before proper disposal.

If the battery is needed to be stored for an long period, battery should be removed from the

application and stored in a place where humidity and temperature are low.

While the battery is charged, used and stored, keep it away from object materials with static electric

chargers.

Safety Handling Procedure for the Transporter

■ Quarantine : Packages that are crushed, punctured or torn open to reveal contents should not be

transported. Such packages should be isolated until the shipper has been consulted,

provided instructions and, if appropriate, arranged to have the product inspected and

repacked.

■ Spilled Product : In the event that damage to packaging results in the release of cells or batteries,

the spilled products should be promptly collected and segregated and the shipper

should be contacted for instructions.

Design of positioning the battery pack in application and charger

To prevent the deterioration of the battery performance caused by heat, battery shall be positioned

away from the area where heat is generated in the application and the charger.

Design of the Battery Pack

Be sure adopting proper safe device such as PTC specified type or model in Cell Specification. If you

intend to adopt different safety device which is not specified in Cell Specification, please contact

Samsung SDI to investigate any potential safety problem.

Be sure designing 2nd protective devices such as PTC & PCM at the same time to protect Cell just in

case one protective device is fault.

Please contact following offices when you need any help including safety concerns.

17

Battery Division -SAMSUNG SDI Confidential Proprietary –

Spec. No.

ICP663450A Version No. 0.0

Samsung SDI Emergency Contact Information

■ Samsung SDI Headquarter.

20th Fl., Samsung Life Insurance Bldg. 150, 2-ka, Taepyung-Ro, Chung-Ku, Seoul, Korea 100-720

Tel:(+82)2-727-3686 Fax:(+82)2-727-3689 E-mail: onekim@

■ Samsung SDI Chonan factory.

508, Sungsung-Dong, Chonan City, Chungchongnam-Do, Korea

Tel:(+82)41-624-3669 Fax:(+82)41-624-3697

■ Samsung SDI America office.

18600 Broadwick Street Rancho Dominguez CA 90180

Tel:(+1)310-900-5205 Fax:(+1)310-537-1033

■ Samsung SDI Taiwan office.

Rm. 3010, 30F., 333, Keelung Rd. Sec. 1, Taipei, Taiwan

Tel:(+886)2-2728-8469 Fax:(+886)2-2728-8480

18

Battery Division

2023年12月6日发(作者:黎飞兰)

-SAMSUNG SDI Confidential Proprietary –

Spec. No.

ICP663450A Version No. 0.0

SPECIFICATION OF PRODUCT

SPECIFICATION OF PRODUCT

for Lithium-ion Rechargeable Cell

Model : ICP663450A

Fed. 8th, 2007

Samsung SDI Co.,Ltd.

Battery Division -SAMSUNG SDI Confidential Proprietary –

Spec. No.

ICP663450A Version No. 0.0

SPECIFICATIONS

1. Scope

This product specification has been prepared to specify the rechargeable lithium-ion cell

('cell') to be supplied to the customer by Samsung SDI Co., Ltd.

2. Description and Model

2.1 Description Cell (lithium-ion rechargeable cell)

2.2 Model ICP663450A

3. Nominal Specifications

Item

3.1 Nominal Capacity

3.2 Charging Voltage

3.3 Nominal Voltage

3.4 Charging Method

3.5 Charging Current

3.6 Charging Time

3.7 Max. Charge Current

3.8 Max. Discharge Current

3.9 Discharge Cut-off Voltage

3.10 Cell Weight

3.11 Cell Dimension

3.12 Operating Temperature

3.13 Storage Temperature

Note (1): If the cell is kept as ex-factory status (50~60% of Charge state),

the capacity recovery rate is more than 80%.

Specification

1330mAh (0.2C discharge)

4.2V

3.7V

CC-CV (constant voltage with limited current)

Standard charge: 665mA

Rapid charge: 1330mA

Standard charge: 3hours

Rapid charge: 2.5hours

1330mA

2660mA

2.75V

Max. 28.0g

Thickness: Max. 6.60mm (Initial fully charged cell)

Width: Max. 34.0mm

Height: Max. 50.0mm

Charge : 0 to 45℃

Discharge: –20 to 60℃

1 year : -20~25℃(1*)

3 months : -20~45℃(1*)

1 month : -20~60℃(1*)

1

Battery Division -SAMSUNG SDI Confidential Proprietary –

Spec. No.

ICP663450A Version No. 0.0

4. Outline Dimensions

See the attachment (Fig. 1)

5. Appearance

There shall be no such defects as scratch, rust, discoloration, leakage which

may adversely affect commercial value of the cell.

6. Standard Test Conditions

6.1 Environmental Conditions

Unless otherwise specified, all tests stated in this specification are conducted

at temperature 25±3℃ and humidity 65±20%.

6.2 Measuring Equipment

(1) Ammeter and Voltmeter

The ammeter and voltmeter should have an accuracy of the grade 0.5 or higher.

(2) Slide caliper

The slide caliper should have 0.05 mm scale.

(3) Impedance meter

The impedance meter with AC 1kHz should be used.

7. Characteristics

7.1 Standard Charge

This "Standard Charge" means charging the cell with charge current 665mA

and constant voltage 4.2V at 25℃ for 3hours.

7.2 Rated Charge

This "Rated Charge" means charging the cell with charge current 650mA

and constant voltage 4.2V and 0.05C(=65mA) cut-off at 25℃.

7.3 Standard Discharge Capacity

The standard discharge capacity is the initial discharge capacity of the cell, which is

measured with discharge current of 266mA with 2.75V cut-off at 25℃ within 1 hour

after the standard charge.

Standard Discharge Capacity

≥ 1330mAh

7.4 Rated Discharge Capacity

The rated discharge capacity is the initial discharge capacity of the cell, which is

measured with discharge current of 650mA with 3.2V cut-off at 25℃ within 1 hour

after the rated charge.

Rated Discharge Capacity

≥ 650mAh

2

Battery Division -SAMSUNG SDI Confidential Proprietary –

Spec. No.

ICP663450A Version No. 0.0

7.5 Pulse Discharge

Cell shall be discharged at a constant current rate of 1C to 3.2V.

Cells shall be also discharged per the pulse profile described figure.1 until 3.2V.

Figure 1. Pulse Profile

1.5A80mA0.6ms

4ms

7.6 Initial internal impedance

Initial internal impedance measured at AC 1kHz after rated charge.

Initial internal impedance range of 45

± 15mΩ

7.7 Charge Rate Capabilities

Discharge capacity is measured with constant current 650mA and 3.2V cut-off

after the cell is charged with 4.2V as follows.

Current

Cut-off

0.2C

(260mA)

0.05C

Charge Condition

0.5C

(650mA)

0.05C

1.0C

(1300mA)

0.05C

2.0C

(2600mA)

0.05C

Relative

100% 100% 100% 90%

Capacity

Note: Percentage as an index of the rated discharge capacity (=1300mAh) is 100%.

7.8 Discharge Rate Capabilities

Discharge capacity is measured with the various currents in under table and 3.2V

cut-off after the rated charge.

3

Battery Division -SAMSUNG SDI Confidential Proprietary –

Spec. No.

ICP663450A Version No. 0.0

Current

Relative

Capacity

0.2C

(260mA)

102%

Discharge Condition

0.5C

(650mA)

100%

1.0C

(650mA)

95%

2.0C

(2600mA)

80%

Pulse

100%

Note: Percentage as an index of the rated discharge capacity (=1300mAh) is 100%.

7.9 Temperature Dependence of Discharge Capacity

Capacity comparison at each temperature, measured with discharge

constant current 650mA and 3.2V cut-off after the rated charge is as follows.

Charge Temperature

25℃

Relative Capacity

-20℃

5%

Discharge temperature (0.5C)

-10℃

40%

0℃

80%

25℃

100%

40℃

100%

60℃

90%

Note: If charge temperature and discharge temperature is not the same,

the interval for temperature change is 2 hours.

Percentage as an index of the rated discharge capacity (=1300mAh) is 100%.

Charge Temperature

25℃

Relative Capacity

-20℃

5%

Discharge temperature (Pulse)

-10℃

40%

0℃

80%

25℃

100%

40℃

100%

60℃

90%

7.10 Temperature Dependence of Charge Capacity

Capacity comparison at each temperature, measured with discharge

constant current 650mA and 3.2V cut-off after the rated charge is as follows.

Relative Capacity

Charge temperature

0℃

80%

25℃

100%

40℃

100%

Discharge temperature

25℃

Note: If charge temperature and discharge temperature is not the same,

the interval for temperature change is 2 hours.

Percentage as an index of the rated discharge capacity (=1300mAh) is 100%.

7.10 Cycle Life

Each cycle is an interval between the charge (charge current 1300mA) with

0.05C cut-off and the discharge (discharge current 1300mA) with 3.2V cut-off.

4

Battery Division -SAMSUNG SDI Confidential Proprietary –

Spec. No.

ICP663450A Version No. 0.0

Capacity is measured at 100cycles,300cycles and 500cycles.

100cyc. Capacity

≥ 1170mAh (90% of the rated discharge capacity)

300cyc. Capacity

≥ 1105mAh (85% of the rated discharge capacity)

500cyc. Capacity

≥ 1040mAh (80% of the rated discharge capacity)

7.11 Storage Characteristics

Capacity after storage for 30days at 25℃ after the rated charged measured with

discharge current 650mA with 3.2V cut-off at 25℃.

Capacity retention(after the storage)

≥ 1235mAh (95% of the rated discharge capacity)

8. Mechanical Characteristics

8.1 Drop Test

Test method: Cell(rated charged) is dropped onto the steel plate (thickness≥10mm)

from 1.5m height at each side 3 times and a random direction 2 times.

(Total 20 times)

Criteria: No leakage, Open circuit voltage

≥ 4.0V, IR < 100mΩ

8.2 Vibration Test

Test method: Cell(rated charged) is vibrated only up and down direction

with vibration cycling that consists of 10Hz to 500Hz and 500Hz to 1800Hz

during 45min per each mode (ASD: 0.1g2/Hz, Average Acceleration:

6gRMS) at 25℃±3℃.

Criteria: No leakage, Open circuit voltage

≥ 4.0V, IR < 100mΩ

9. Environmental Characteristics

9.1 Thermal Shock

Test method: Cell(rated charged) is repeatedly tested with 30 times heat cycling, which

means maintaining the cell for 1hours at –40℃ and 85℃ respectively.

Inspect its appearance and measure its thickness right after thermal shock.

Measure the recovered capacity by rated charge/discharge cycling after

rated discharging(650mA, 3.2V cut-off) at 25℃.

Criteria: No leakage, Cell thickness < 7.26mm

Recovery > 1040mAh (80% of the rated discharge capacity)

9.2 Humidity

Test method: Cell(rated charged) is exposed to 50℃,95%RH. for 10days

5

Battery Division -SAMSUNG SDI Confidential Proprietary –

Spec. No.

ICP663450A Version No. 0.0

Inspect appearance and measure thickness right after humidity test.

Measure the recovered capacity by rated charge/discharge cycling after

rated discharging(650mA, 3.2V cut-off) at 25℃.

Criteria: No leakage, Cell thickness < 6.93mm,

Recovery > 1170mAh (90% of the rated discharge capacity)

9.3 Life cycle at low temperature

Repeat 10times of cycles(Discharging first) at 0℃(Charge :1C,4.2V,0.05C cut off,

Discharge: 1C, 3.2V), and measure IR & thickness after 5ycles and 10cycles, after

cycling test, measure the IR & thickness after stand 2hours at 25±3℃.

Criteria: 10cyc. Thickness < 6.93mm

9.4 Low Pressure

Cell(rated charged) is deposited into the vacuum chamber in pressure 11.6kPa for

6hours at 25±3℃, inspect appearance and measure the IR & voltage after test

Criteria: No leakage, Open circuit voltage

≥ 4.0V, IR < 100mΩ

9.5 Abnormal charge

Test method: To charge the rate charged cell to 4.25V, 4.275V and 4.30V and with

constant current of 700mA for 168hours at 25℃.

Criteria: Thickness < 7.10mm

10. Safety

Safety Test shall be performed with the following criteria

- UL1642

- Fully Charged Cell

- No protection component/circuit on the battery cell, i.e. bare cell.

Testing shall be performed at 25℃±3℃.

There should be neither fire nor explosion after testing under the temperature of 200℃.

10.1 Overcharge Test (without PTC)

Test method: To charge the standard charged cell with 5V and 1.0A at 25℃

for 2.5 hours.

Criteria: No fire, and no explosion.

6

Battery Division -SAMSUNG SDI Confidential Proprietary –

Spec. No.

ICP663450A Version No. 0.0

10.2 External Short-circuit Test

Test method: The cell shall be fully charged, it is stored in ambient temperature of 60℃.

Each test sample is short-circuited by connecting positive and negative

terminal with less than 100mΩ wire. And stand for 2.5 hours

Criteria: No smoke, No fire, and no explosion.

10.3 Reverse Charge Test

Test method: To charge reverse the standard charged cell with charge current 1330mA

for 2.5 hours.

Criteria: No fire, and no explosion.

10.4 Nail Penetrating Test

Test method: Cell shall be fully charged. Penetrate completely center of cell with

5mm diameter nail at the velocity of 40mm/sec.

Criteria: No fire, and no explosion.

10.5 Heating Test

Test method: To heat the standard charged cell at heating rate 5℃ per minute up to

150℃ and keep the cell in oven for 60 minutes.

Criteria: No fire, and no explosion within 10min.

10.6 Crush

Test method: To crush the standard charged cell with force of 13kN.

(Crushed side is longitudinal and narrow axis.)

Criteria: No fire, and no explosion.

10.7 Impact

Test method: To place 15.8mm diameter bar across the center of standard charged cell,

and drop 9.1kg weight from 610±25mm height onto the cell.

(Impacted side is longitudinal and wide axis.)

Criteria: No fire, and no explosion.

7

Battery Division -SAMSUNG SDI Confidential Proprietary –

Spec. No.

ICP663450A Version No. 0.0

11. Warranty

Samsung SDI will be responsible for replacing the cell against defects or poor workmanship

for 1year from the date of shipping. Any other problem caused by malfunction of the

equipment or unsuitable use of the cell is not under this warranty.

The warranty set forth in proper using and handling conditions described above and

excludes in the case of a defect which is not related to manufacturing of the cell.

[ Disclaimer ]

This Specification stipulates the final and comprehensive requirements for the respective

products hereof. beyond this Specification, it is the responsibility of the customer to

explicitly disclose any additional requirements, information or reservations regarding these

requirements to Samsung SDI prior to implementation,

where any and all disclosures of the customer shall be with an authorized representative of

Samsung SDI in writing.

Samsung SDI shall not be responsible for safety, performance, functionality or compatibility

of the system with which the Samsung SDI-supplied components are integrated unless

such features have been expressly communicated and described in the Specification.

SAMSUNG SDI MAKES NO GUARANTY OR WARRANTY, EXPRESS OR IMPLIED,

INCLUDING BUT NOT LIMITED TO MERCHANTABILITY OR FITNESS FOR A

PARTICULAR PURPOSE, TO ANY PARTY.

Moreover, any party should do their own due diligence regarding these requirements prior

to implementation.

12. Others

12.1 Storage for a long time

If the cell is kept for a long time(3months or more), It is strongly recommended

that the cell is preserved at dry and low-temperature.

12.2 PTC (Positive Temperature Coefficient)

The recommended PTC model : RayChem(Japan), VTP175LF MXP190S, and

Polytronics (Japan), SLD190VF

The max. discharge current of cell with PTC depends on temperature.

12.3 Other

Any matters that specifications does not have, should be conferred with

between the both parties.

8

Battery Division -SAMSUNG SDI Confidential Proprietary –

Spec. No.

ICP663450A Version No. 0.0

Fig.1. ICP663450A

EX-Factory status 6.35mm +0/-0.3

Initial Full Charge status Max 6.60mm

9

Battery Division -SAMSUNG SDI Confidential Proprietary –

Spec. No.

ICP663450A Version No. 0.0

Proper Use and Handling of Lithium Ion Cells

See before using lithium-ion cell

Supplied by Samsung SDI Co., Ltd.

1. General

This document has been prepared to describe the appropriate cautions and

prohibitions, which the customer should take or employ when the customer uses

and handles the lithium ion cell to be manufactured and supplied by Samsung SDI Co.,

Ltd., in order to obtain optimum performance and safety.

2. Charging

2.1 Charging current

Charging current should be less than maximum charge current specified in the product

specification.

2.2 Charging voltage

Charging should be done by voltage less than that specified in the product specification.

2.3 Charging time

Continuous charging under appropriate voltage does not cause any loss of

characteristics. However, the charge timer is recommended to be installed from a safety

consideration, which shuts off further charging at time specified in the product

specification.

2.4 Charging temperature

The cell should be charged within a range of specified temperatures in the product

specification.

2.5 Reverse charging

The cell should be connected, confirming that its poles are correctly aligned.

Inverse charging should be strictly prohibited. If the cell is connected improperly,

it may be damaged.

3. Discharging

3.1 Discharging

3.1.1 The cell should be discharged at less than maximum discharge current

specified in the product specification.

10

Battery Division -SAMSUNG SDI Confidential Proprietary –

Spec. No.

ICP663450A Version No. 0.0

3.2 Discharging temperature

3.2.1 The cell should be discharged within a range of temperatures specified in

the product specification.

3.2.2 Otherwise, it may cause loss of characteristics.

3.3 Over-discharging

3.3.1 The system should equip with a device to prevent further discharging

exceeding discharging cut-off voltage specified in the product

specification.(over-discharging)

3.3.2 Over-discharging may cause loss of performance, characteristics, of

battery function.

3.3.3 Over-discharging may occur by self-discharge if the battery is left for

a very long time without any use.

3.3.4 The charger should equip with a device to detect cell voltage and to

determine recharging procedures.

4. Storage

4.1 Storage conditions

4.1.1 The cell should be stored within a range of temperatures specified

in the product specification.

4.1.2 Otherwise, it may cause loss of characteristics, leakage and/or rust.

4.2 Long-term storage

4.2.1 The cell should be used within a short period after charging because

long-term storage may cause loss of capacity by self-discharging.

4.2.2. If long-term storage is necessary, the cell should be stored at lower

voltage within a range specified in the product specification, because

storage at higher voltage may cause loss of characteristics.

5. Cycle life

5.1 Cycle life performance

5.1.1 The cell can be charged/discharged repeatedly up to times specified in

the produce specification with a certain level of capacity also specified

in the product specification.

5.1.2 Cycle life may be determined by conditions of charging, discharging,

operating temperature and/or storage.

11

Battery Division -SAMSUNG SDI Confidential Proprietary –

Spec. No.

ICP663450A Version No. 0.0

6. Design of System

6.1 Connection between the cell and the battery

6.1.1 The cell should not be soldered directly with leads. Namely, the cell

should be welded with leads on its terminal and then be soldered with

wire or leads to soldered lead.

6.1.2 Otherwise, it may cause damage of component, such as separator and

insulator, by heat generation.

6.2 Positioning the battery in the System

6.2.1 The battery should be positioned as possible as far from heat sources

and high temperature components.

6.2.2 Otherwise, it may cause loss of characteristics.

6.3 Mechanical shock protection of the battery

6.3.1 The battery should equip with appropriate shock absorbers in order to

minimize shock.

6.3.2 Otherwise, it may cause shape distortion, leakage, heat generation

and/or rupture.

6.4 Short-circuit protection of the cell

6.4.1 The cell equips with an insulating sleeve to protect short-circuit which

may occur during transportation, battery assembly and /or system

operation.

6.4.2 If the cell sleeve is damaged by some cause such as outside impact,

it may cause short-circuit with some wiring inside the battery.

6.5 Connection between the battery and charger/system

6.5.1 The battery should be designed to be connected only to the specified

charger and system.

6.5.2 A reverse connection of the battery, even in the specified system,

should be avoided by employing special battery design such as

a special terminals.

7. Battery Pack Assembly

7.1 Prohibition of usage of damaged cell

7.1.1 The cell should be inspected visually before battery assembly.

7.1.2 The cell should not be used if sleeve-damage, can-distortion and/or

electrolyte-smell is detected.

12

Battery Division -SAMSUNG SDI Confidential Proprietary –

Spec. No.

ICP663450A Version No. 0.0

7.2 Terminals handling

7.2.1 Excessive force on the negative terminal should be avoided when

external lead is welled.

7.3 Transportation

7.3.1 If the cell is necessary to transported to order place, such as the

battery manufacturer, careful precautions should be taken to avoid

damage of cell.

8. Others

8.1 Disassembly

8.1.1 The cell should not be dismantled from the battery pack.

8.1.2 Internal short-circuit caused by disassembly may lead to heat generation

and/or venting.

8.1.3 When the electrolyte is coming in contact with the skin or eyes,

flush immediately with fresh water and seek medical advice.

8.2 Short-circuiting

8.2.1 Short-circuit results in very high current which leads to heat generation.

8.2.3 An appropriate circuitry should be employed to protect accidental

short-circuiting.

8.3 Incineration

8.3.1 Incinerating and disposing of the cell in fire are strictly prohibited,

because it may cause rupture.

8.4 Immersion

8.4.1 Soaking the cell in water is strictly prohibited, because it may cause

melt of components to damaged to functions.

8.5 Mixing use

8.5.1 Different types of cell, or same types but different manufacturer's cell

may lead to cell rupture or damage to system due to the different

characteristics of cell.

8.6 Battery exchange

8.6.1 Although the cell contains no environmentally hazardous component,

such as lead or cadmium. the battery should be disposed according to

the local regulations when it is disposed.

13

Battery Division -SAMSUNG SDI Confidential Proprietary –

Spec. No.

ICP663450A Version No. 0.0

8.6.2 The cell should be disposed with a discharged state to avoid heat generation

by an inadvertent short-circuit.

8.7 Caution

"The Battery used in this device may present a risk of fire or chemical burn if mistreated.

Do not disassemble, heat above 100℃ or incinerate. Replace battery with Samsung

SDI battery only. Use of another battery may present a risk of fire or explosion.

Dispose of used battery promptly. Keep away from children. Do not disassemble and do

not dispose of in fire."

14

Battery Division -SAMSUNG SDI Confidential Proprietary –

Spec. No.

8.8 Warning

ICP663450A Version No. 0.0

Handling Precaution and Prohibitions of Lithium Ion & Lithium Ion Polymer

Rechargeable Cells and Batteries

Inaccurate handling of lithium ion and lithium ion polymer rechargeable battery may cause leakage, heat,

smoke, an explosion, or fire.

This could cause deterioration of performance or failure. Please be sure to follow instructions carefully.

1.1 Storage

Store the battery at low temperature (below 20℃ is recommended), low humidity, no dust and no

corrosive gas atmosphere.

1.2 Safety precaution and prohibitions

To assure product safety, describe the following precautions in the instruction manual of the

application.

[ Danger!]

■ Electrical misusage

Use dedicated charger.

Use or charge the battery only in the dedicated application.

Don't charge the battery by an electric outlet directly or a cigarette lighter charger.

Don't charge the battery reversely.

■ Environmental misusage

Don't leave the battery near the fire or a heated source.

Don't throw the battery into the fire.

Don't leave, charge or use the battery in a car or similar place where inside of temperature may be

over 60℃.

Don't immerse, throw, wet the battery in water / seawater.

■ others

Don't fold the battery cased with laminated film such as pouch and Polymer.

Don't store the battery in a pocket or a bag together with metallic objects such as keys, necklaces,

hairpins, coins, or screws.

Don't short circuit (+) and (-) terminals with metallic object intentionally.

Don't pierce the battery with a sharp object such as a needle, screw drivers.

Don't heat partial area of the battery with heated objects such as soldering iron.

Don't hit with heavy objects such as a hammer, weight.

Don't step on the battery and throw or drop the battery on the hard floor to avoid mechanical shock.

15

Battery Division -SAMSUNG SDI Confidential Proprietary –

Spec. No.

ICP663450A Version No. 0.0

Don't disassemble the battery or modify the battery design including electric circuit.

Don't solder on the battery directly.

Don't use seriously scared or deformed battery.

Don't put the battery into a microwave oven, dryer ,or high-pressure container.

Don't use or assemble the battery with other makers' batteries, different types and/or models of

batteries such as dry batteries, nickel-metal hydride batteries, or nickel-cadmium batteries.

Don't use or assemble old and new batteries together.

[ Warning! ]

Stop charging the battery if charging isn't completed within the specified time.

Stop using the battery if the battery becomes abnormally hot, order, discoloration, deformation, or

abnormal conditions is detected during use, charge, or storage.

Keep away from fire immediately when leakage or foul odors are detected. If liquid leaks onto your

skin or cloths, wash well with fresh water immediately.

If liquid leaking from the battery gets into your eyes, don't rub your eyes and wash them with clean

water and go to see a doctor immediately.

If the terminals of the battery become dirty, wipe with a dry cloth before using the battery.

The battery can be used within the following temperature ranges. Don't exceed these ranges.

Charge temperature ranges : 0℃ ~ 45℃

Discharge Temperature ranges : -20℃ ~ 60℃

Store the battery at temperature below 60℃

Cover terminals with proper insulating tape before disposal.

[ Caution! ]

■ Electrical misusage

Battery must be charge with constant current-constant voltage (CC/CV).

Charge current must be controlled by specified value in Cell specification.

Cut-off Voltage of charging must be 4.2V.

Charger must stop charging battery by detecting either charging time or current specified in Cell’s

specification.

Discharge current must be controlled by specified value in Cell’s specification.

Cut-off Voltage of discharging must be over 2.5V.

16

Battery Division -SAMSUNG SDI Confidential Proprietary –

Spec. No.

■ others

ICP663450A Version No. 0.0

Keep the battery away from babies and children to avoid any accidents such as swallow.

If younger children use the battery, their guardians should explain the proper handling method and

precaution before using.

Before using the battery, be sure to read the user's manual and precaution of it's handling.

Before using charger, be sure to read the user's manual of the charger.

Before installing and removing the battery from application, be sure to read user's manual of the

application.

Replace the battery when using time of battery becomes much shorter than usual.

Cover terminals with insulating tape before proper disposal.

If the battery is needed to be stored for an long period, battery should be removed from the

application and stored in a place where humidity and temperature are low.

While the battery is charged, used and stored, keep it away from object materials with static electric

chargers.

Safety Handling Procedure for the Transporter

■ Quarantine : Packages that are crushed, punctured or torn open to reveal contents should not be

transported. Such packages should be isolated until the shipper has been consulted,

provided instructions and, if appropriate, arranged to have the product inspected and

repacked.

■ Spilled Product : In the event that damage to packaging results in the release of cells or batteries,

the spilled products should be promptly collected and segregated and the shipper

should be contacted for instructions.

Design of positioning the battery pack in application and charger

To prevent the deterioration of the battery performance caused by heat, battery shall be positioned

away from the area where heat is generated in the application and the charger.

Design of the Battery Pack

Be sure adopting proper safe device such as PTC specified type or model in Cell Specification. If you

intend to adopt different safety device which is not specified in Cell Specification, please contact

Samsung SDI to investigate any potential safety problem.

Be sure designing 2nd protective devices such as PTC & PCM at the same time to protect Cell just in

case one protective device is fault.

Please contact following offices when you need any help including safety concerns.

17

Battery Division -SAMSUNG SDI Confidential Proprietary –

Spec. No.

ICP663450A Version No. 0.0

Samsung SDI Emergency Contact Information

■ Samsung SDI Headquarter.

20th Fl., Samsung Life Insurance Bldg. 150, 2-ka, Taepyung-Ro, Chung-Ku, Seoul, Korea 100-720

Tel:(+82)2-727-3686 Fax:(+82)2-727-3689 E-mail: onekim@

■ Samsung SDI Chonan factory.

508, Sungsung-Dong, Chonan City, Chungchongnam-Do, Korea

Tel:(+82)41-624-3669 Fax:(+82)41-624-3697

■ Samsung SDI America office.

18600 Broadwick Street Rancho Dominguez CA 90180

Tel:(+1)310-900-5205 Fax:(+1)310-537-1033

■ Samsung SDI Taiwan office.

Rm. 3010, 30F., 333, Keelung Rd. Sec. 1, Taipei, Taiwan

Tel:(+886)2-2728-8469 Fax:(+886)2-2728-8480

18

Battery Division

发布评论

评论列表 (0)

  1. 暂无评论