2023年12月6日发(作者:黎飞兰)
-SAMSUNG SDI Confidential Proprietary –
Spec. No.
ICP663450A Version No. 0.0
SPECIFICATION OF PRODUCT
SPECIFICATION OF PRODUCT
for Lithium-ion Rechargeable Cell
Model : ICP663450A
Fed. 8th, 2007
Samsung SDI Co.,Ltd.
Battery Division -SAMSUNG SDI Confidential Proprietary –
Spec. No.
ICP663450A Version No. 0.0
SPECIFICATIONS
1. Scope
This product specification has been prepared to specify the rechargeable lithium-ion cell
('cell') to be supplied to the customer by Samsung SDI Co., Ltd.
2. Description and Model
2.1 Description Cell (lithium-ion rechargeable cell)
2.2 Model ICP663450A
3. Nominal Specifications
Item
3.1 Nominal Capacity
3.2 Charging Voltage
3.3 Nominal Voltage
3.4 Charging Method
3.5 Charging Current
3.6 Charging Time
3.7 Max. Charge Current
3.8 Max. Discharge Current
3.9 Discharge Cut-off Voltage
3.10 Cell Weight
3.11 Cell Dimension
3.12 Operating Temperature
3.13 Storage Temperature
Note (1): If the cell is kept as ex-factory status (50~60% of Charge state),
the capacity recovery rate is more than 80%.
Specification
1330mAh (0.2C discharge)
4.2V
3.7V
CC-CV (constant voltage with limited current)
Standard charge: 665mA
Rapid charge: 1330mA
Standard charge: 3hours
Rapid charge: 2.5hours
1330mA
2660mA
2.75V
Max. 28.0g
Thickness: Max. 6.60mm (Initial fully charged cell)
Width: Max. 34.0mm
Height: Max. 50.0mm
Charge : 0 to 45℃
Discharge: –20 to 60℃
1 year : -20~25℃(1*)
3 months : -20~45℃(1*)
1 month : -20~60℃(1*)
1
Battery Division -SAMSUNG SDI Confidential Proprietary –
Spec. No.
ICP663450A Version No. 0.0
4. Outline Dimensions
See the attachment (Fig. 1)
5. Appearance
There shall be no such defects as scratch, rust, discoloration, leakage which
may adversely affect commercial value of the cell.
6. Standard Test Conditions
6.1 Environmental Conditions
Unless otherwise specified, all tests stated in this specification are conducted
at temperature 25±3℃ and humidity 65±20%.
6.2 Measuring Equipment
(1) Ammeter and Voltmeter
The ammeter and voltmeter should have an accuracy of the grade 0.5 or higher.
(2) Slide caliper
The slide caliper should have 0.05 mm scale.
(3) Impedance meter
The impedance meter with AC 1kHz should be used.
7. Characteristics
7.1 Standard Charge
This "Standard Charge" means charging the cell with charge current 665mA
and constant voltage 4.2V at 25℃ for 3hours.
7.2 Rated Charge
This "Rated Charge" means charging the cell with charge current 650mA
and constant voltage 4.2V and 0.05C(=65mA) cut-off at 25℃.
7.3 Standard Discharge Capacity
The standard discharge capacity is the initial discharge capacity of the cell, which is
measured with discharge current of 266mA with 2.75V cut-off at 25℃ within 1 hour
after the standard charge.
Standard Discharge Capacity
≥ 1330mAh
7.4 Rated Discharge Capacity
The rated discharge capacity is the initial discharge capacity of the cell, which is
measured with discharge current of 650mA with 3.2V cut-off at 25℃ within 1 hour
after the rated charge.
Rated Discharge Capacity
≥ 650mAh
2
Battery Division -SAMSUNG SDI Confidential Proprietary –
Spec. No.
ICP663450A Version No. 0.0
7.5 Pulse Discharge
Cell shall be discharged at a constant current rate of 1C to 3.2V.
Cells shall be also discharged per the pulse profile described figure.1 until 3.2V.
Figure 1. Pulse Profile
1.5A80mA0.6ms
4ms
7.6 Initial internal impedance
Initial internal impedance measured at AC 1kHz after rated charge.
Initial internal impedance range of 45
± 15mΩ
7.7 Charge Rate Capabilities
Discharge capacity is measured with constant current 650mA and 3.2V cut-off
after the cell is charged with 4.2V as follows.
Current
Cut-off
0.2C
(260mA)
0.05C
Charge Condition
0.5C
(650mA)
0.05C
1.0C
(1300mA)
0.05C
2.0C
(2600mA)
0.05C
Relative
100% 100% 100% 90%
Capacity
Note: Percentage as an index of the rated discharge capacity (=1300mAh) is 100%.
7.8 Discharge Rate Capabilities
Discharge capacity is measured with the various currents in under table and 3.2V
cut-off after the rated charge.
3
Battery Division -SAMSUNG SDI Confidential Proprietary –
Spec. No.
ICP663450A Version No. 0.0
Current
Relative
Capacity
0.2C
(260mA)
102%
Discharge Condition
0.5C
(650mA)
100%
1.0C
(650mA)
95%
2.0C
(2600mA)
80%
Pulse
100%
Note: Percentage as an index of the rated discharge capacity (=1300mAh) is 100%.
7.9 Temperature Dependence of Discharge Capacity
Capacity comparison at each temperature, measured with discharge
constant current 650mA and 3.2V cut-off after the rated charge is as follows.
Charge Temperature
25℃
Relative Capacity
-20℃
5%
Discharge temperature (0.5C)
-10℃
40%
0℃
80%
25℃
100%
40℃
100%
60℃
90%
Note: If charge temperature and discharge temperature is not the same,
the interval for temperature change is 2 hours.
Percentage as an index of the rated discharge capacity (=1300mAh) is 100%.
Charge Temperature
25℃
Relative Capacity
-20℃
5%
Discharge temperature (Pulse)
-10℃
40%
0℃
80%
25℃
100%
40℃
100%
60℃
90%
7.10 Temperature Dependence of Charge Capacity
Capacity comparison at each temperature, measured with discharge
constant current 650mA and 3.2V cut-off after the rated charge is as follows.
Relative Capacity
Charge temperature
0℃
80%
25℃
100%
40℃
100%
Discharge temperature
25℃
Note: If charge temperature and discharge temperature is not the same,
the interval for temperature change is 2 hours.
Percentage as an index of the rated discharge capacity (=1300mAh) is 100%.
7.10 Cycle Life
Each cycle is an interval between the charge (charge current 1300mA) with
0.05C cut-off and the discharge (discharge current 1300mA) with 3.2V cut-off.
4
Battery Division -SAMSUNG SDI Confidential Proprietary –
Spec. No.
ICP663450A Version No. 0.0
Capacity is measured at 100cycles,300cycles and 500cycles.
100cyc. Capacity
≥ 1170mAh (90% of the rated discharge capacity)
300cyc. Capacity
≥ 1105mAh (85% of the rated discharge capacity)
500cyc. Capacity
≥ 1040mAh (80% of the rated discharge capacity)
7.11 Storage Characteristics
Capacity after storage for 30days at 25℃ after the rated charged measured with
discharge current 650mA with 3.2V cut-off at 25℃.
Capacity retention(after the storage)
≥ 1235mAh (95% of the rated discharge capacity)
8. Mechanical Characteristics
8.1 Drop Test
Test method: Cell(rated charged) is dropped onto the steel plate (thickness≥10mm)
from 1.5m height at each side 3 times and a random direction 2 times.
(Total 20 times)
Criteria: No leakage, Open circuit voltage
≥ 4.0V, IR < 100mΩ
8.2 Vibration Test
Test method: Cell(rated charged) is vibrated only up and down direction
with vibration cycling that consists of 10Hz to 500Hz and 500Hz to 1800Hz
during 45min per each mode (ASD: 0.1g2/Hz, Average Acceleration:
6gRMS) at 25℃±3℃.
Criteria: No leakage, Open circuit voltage
≥ 4.0V, IR < 100mΩ
9. Environmental Characteristics
9.1 Thermal Shock
Test method: Cell(rated charged) is repeatedly tested with 30 times heat cycling, which
means maintaining the cell for 1hours at –40℃ and 85℃ respectively.
Inspect its appearance and measure its thickness right after thermal shock.
Measure the recovered capacity by rated charge/discharge cycling after
rated discharging(650mA, 3.2V cut-off) at 25℃.
Criteria: No leakage, Cell thickness < 7.26mm
Recovery > 1040mAh (80% of the rated discharge capacity)
9.2 Humidity
Test method: Cell(rated charged) is exposed to 50℃,95%RH. for 10days
5
Battery Division -SAMSUNG SDI Confidential Proprietary –
Spec. No.
ICP663450A Version No. 0.0
Inspect appearance and measure thickness right after humidity test.
Measure the recovered capacity by rated charge/discharge cycling after
rated discharging(650mA, 3.2V cut-off) at 25℃.
Criteria: No leakage, Cell thickness < 6.93mm,
Recovery > 1170mAh (90% of the rated discharge capacity)
9.3 Life cycle at low temperature
Repeat 10times of cycles(Discharging first) at 0℃(Charge :1C,4.2V,0.05C cut off,
Discharge: 1C, 3.2V), and measure IR & thickness after 5ycles and 10cycles, after
cycling test, measure the IR & thickness after stand 2hours at 25±3℃.
Criteria: 10cyc. Thickness < 6.93mm
9.4 Low Pressure
Cell(rated charged) is deposited into the vacuum chamber in pressure 11.6kPa for
6hours at 25±3℃, inspect appearance and measure the IR & voltage after test
Criteria: No leakage, Open circuit voltage
≥ 4.0V, IR < 100mΩ
9.5 Abnormal charge
Test method: To charge the rate charged cell to 4.25V, 4.275V and 4.30V and with
constant current of 700mA for 168hours at 25℃.
Criteria: Thickness < 7.10mm
10. Safety
Safety Test shall be performed with the following criteria
- UL1642
- Fully Charged Cell
- No protection component/circuit on the battery cell, i.e. bare cell.
Testing shall be performed at 25℃±3℃.
There should be neither fire nor explosion after testing under the temperature of 200℃.
10.1 Overcharge Test (without PTC)
Test method: To charge the standard charged cell with 5V and 1.0A at 25℃
for 2.5 hours.
Criteria: No fire, and no explosion.
6
Battery Division -SAMSUNG SDI Confidential Proprietary –
Spec. No.
ICP663450A Version No. 0.0
10.2 External Short-circuit Test
Test method: The cell shall be fully charged, it is stored in ambient temperature of 60℃.
Each test sample is short-circuited by connecting positive and negative
terminal with less than 100mΩ wire. And stand for 2.5 hours
Criteria: No smoke, No fire, and no explosion.
10.3 Reverse Charge Test
Test method: To charge reverse the standard charged cell with charge current 1330mA
for 2.5 hours.
Criteria: No fire, and no explosion.
10.4 Nail Penetrating Test
Test method: Cell shall be fully charged. Penetrate completely center of cell with
5mm diameter nail at the velocity of 40mm/sec.
Criteria: No fire, and no explosion.
10.5 Heating Test
Test method: To heat the standard charged cell at heating rate 5℃ per minute up to
150℃ and keep the cell in oven for 60 minutes.
Criteria: No fire, and no explosion within 10min.
10.6 Crush
Test method: To crush the standard charged cell with force of 13kN.
(Crushed side is longitudinal and narrow axis.)
Criteria: No fire, and no explosion.
10.7 Impact
Test method: To place 15.8mm diameter bar across the center of standard charged cell,
and drop 9.1kg weight from 610±25mm height onto the cell.
(Impacted side is longitudinal and wide axis.)
Criteria: No fire, and no explosion.
7
Battery Division -SAMSUNG SDI Confidential Proprietary –
Spec. No.
ICP663450A Version No. 0.0
11. Warranty
Samsung SDI will be responsible for replacing the cell against defects or poor workmanship
for 1year from the date of shipping. Any other problem caused by malfunction of the
equipment or unsuitable use of the cell is not under this warranty.
The warranty set forth in proper using and handling conditions described above and
excludes in the case of a defect which is not related to manufacturing of the cell.
[ Disclaimer ]
This Specification stipulates the final and comprehensive requirements for the respective
products hereof. beyond this Specification, it is the responsibility of the customer to
explicitly disclose any additional requirements, information or reservations regarding these
requirements to Samsung SDI prior to implementation,
where any and all disclosures of the customer shall be with an authorized representative of
Samsung SDI in writing.
Samsung SDI shall not be responsible for safety, performance, functionality or compatibility
of the system with which the Samsung SDI-supplied components are integrated unless
such features have been expressly communicated and described in the Specification.
SAMSUNG SDI MAKES NO GUARANTY OR WARRANTY, EXPRESS OR IMPLIED,
INCLUDING BUT NOT LIMITED TO MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE, TO ANY PARTY.
Moreover, any party should do their own due diligence regarding these requirements prior
to implementation.
12. Others
12.1 Storage for a long time
If the cell is kept for a long time(3months or more), It is strongly recommended
that the cell is preserved at dry and low-temperature.
12.2 PTC (Positive Temperature Coefficient)
The recommended PTC model : RayChem(Japan), VTP175LF MXP190S, and
Polytronics (Japan), SLD190VF
The max. discharge current of cell with PTC depends on temperature.
12.3 Other
Any matters that specifications does not have, should be conferred with
between the both parties.
8
Battery Division -SAMSUNG SDI Confidential Proprietary –
Spec. No.
ICP663450A Version No. 0.0
Fig.1. ICP663450A
EX-Factory status 6.35mm +0/-0.3
Initial Full Charge status Max 6.60mm
9
Battery Division -SAMSUNG SDI Confidential Proprietary –
Spec. No.
ICP663450A Version No. 0.0
Proper Use and Handling of Lithium Ion Cells
See before using lithium-ion cell
Supplied by Samsung SDI Co., Ltd.
1. General
This document has been prepared to describe the appropriate cautions and
prohibitions, which the customer should take or employ when the customer uses
and handles the lithium ion cell to be manufactured and supplied by Samsung SDI Co.,
Ltd., in order to obtain optimum performance and safety.
2. Charging
2.1 Charging current
Charging current should be less than maximum charge current specified in the product
specification.
2.2 Charging voltage
Charging should be done by voltage less than that specified in the product specification.
2.3 Charging time
Continuous charging under appropriate voltage does not cause any loss of
characteristics. However, the charge timer is recommended to be installed from a safety
consideration, which shuts off further charging at time specified in the product
specification.
2.4 Charging temperature
The cell should be charged within a range of specified temperatures in the product
specification.
2.5 Reverse charging
The cell should be connected, confirming that its poles are correctly aligned.
Inverse charging should be strictly prohibited. If the cell is connected improperly,
it may be damaged.
3. Discharging
3.1 Discharging
3.1.1 The cell should be discharged at less than maximum discharge current
specified in the product specification.
10
Battery Division -SAMSUNG SDI Confidential Proprietary –
Spec. No.
ICP663450A Version No. 0.0
3.2 Discharging temperature
3.2.1 The cell should be discharged within a range of temperatures specified in
the product specification.
3.2.2 Otherwise, it may cause loss of characteristics.
3.3 Over-discharging
3.3.1 The system should equip with a device to prevent further discharging
exceeding discharging cut-off voltage specified in the product
specification.(over-discharging)
3.3.2 Over-discharging may cause loss of performance, characteristics, of
battery function.
3.3.3 Over-discharging may occur by self-discharge if the battery is left for
a very long time without any use.
3.3.4 The charger should equip with a device to detect cell voltage and to
determine recharging procedures.
4. Storage
4.1 Storage conditions
4.1.1 The cell should be stored within a range of temperatures specified
in the product specification.
4.1.2 Otherwise, it may cause loss of characteristics, leakage and/or rust.
4.2 Long-term storage
4.2.1 The cell should be used within a short period after charging because
long-term storage may cause loss of capacity by self-discharging.
4.2.2. If long-term storage is necessary, the cell should be stored at lower
voltage within a range specified in the product specification, because
storage at higher voltage may cause loss of characteristics.
5. Cycle life
5.1 Cycle life performance
5.1.1 The cell can be charged/discharged repeatedly up to times specified in
the produce specification with a certain level of capacity also specified
in the product specification.
5.1.2 Cycle life may be determined by conditions of charging, discharging,
operating temperature and/or storage.
11
Battery Division -SAMSUNG SDI Confidential Proprietary –
Spec. No.
ICP663450A Version No. 0.0
6. Design of System
6.1 Connection between the cell and the battery
6.1.1 The cell should not be soldered directly with leads. Namely, the cell
should be welded with leads on its terminal and then be soldered with
wire or leads to soldered lead.
6.1.2 Otherwise, it may cause damage of component, such as separator and
insulator, by heat generation.
6.2 Positioning the battery in the System
6.2.1 The battery should be positioned as possible as far from heat sources
and high temperature components.
6.2.2 Otherwise, it may cause loss of characteristics.
6.3 Mechanical shock protection of the battery
6.3.1 The battery should equip with appropriate shock absorbers in order to
minimize shock.
6.3.2 Otherwise, it may cause shape distortion, leakage, heat generation
and/or rupture.
6.4 Short-circuit protection of the cell
6.4.1 The cell equips with an insulating sleeve to protect short-circuit which
may occur during transportation, battery assembly and /or system
operation.
6.4.2 If the cell sleeve is damaged by some cause such as outside impact,
it may cause short-circuit with some wiring inside the battery.
6.5 Connection between the battery and charger/system
6.5.1 The battery should be designed to be connected only to the specified
charger and system.
6.5.2 A reverse connection of the battery, even in the specified system,
should be avoided by employing special battery design such as
a special terminals.
7. Battery Pack Assembly
7.1 Prohibition of usage of damaged cell
7.1.1 The cell should be inspected visually before battery assembly.
7.1.2 The cell should not be used if sleeve-damage, can-distortion and/or
electrolyte-smell is detected.
12
Battery Division -SAMSUNG SDI Confidential Proprietary –
Spec. No.
ICP663450A Version No. 0.0
7.2 Terminals handling
7.2.1 Excessive force on the negative terminal should be avoided when
external lead is welled.
7.3 Transportation
7.3.1 If the cell is necessary to transported to order place, such as the
battery manufacturer, careful precautions should be taken to avoid
damage of cell.
8. Others
8.1 Disassembly
8.1.1 The cell should not be dismantled from the battery pack.
8.1.2 Internal short-circuit caused by disassembly may lead to heat generation
and/or venting.
8.1.3 When the electrolyte is coming in contact with the skin or eyes,
flush immediately with fresh water and seek medical advice.
8.2 Short-circuiting
8.2.1 Short-circuit results in very high current which leads to heat generation.
8.2.3 An appropriate circuitry should be employed to protect accidental
short-circuiting.
8.3 Incineration
8.3.1 Incinerating and disposing of the cell in fire are strictly prohibited,
because it may cause rupture.
8.4 Immersion
8.4.1 Soaking the cell in water is strictly prohibited, because it may cause
melt of components to damaged to functions.
8.5 Mixing use
8.5.1 Different types of cell, or same types but different manufacturer's cell
may lead to cell rupture or damage to system due to the different
characteristics of cell.
8.6 Battery exchange
8.6.1 Although the cell contains no environmentally hazardous component,
such as lead or cadmium. the battery should be disposed according to
the local regulations when it is disposed.
13
Battery Division -SAMSUNG SDI Confidential Proprietary –
Spec. No.
ICP663450A Version No. 0.0
8.6.2 The cell should be disposed with a discharged state to avoid heat generation
by an inadvertent short-circuit.
8.7 Caution
"The Battery used in this device may present a risk of fire or chemical burn if mistreated.
Do not disassemble, heat above 100℃ or incinerate. Replace battery with Samsung
SDI battery only. Use of another battery may present a risk of fire or explosion.
Dispose of used battery promptly. Keep away from children. Do not disassemble and do
not dispose of in fire."
14
Battery Division -SAMSUNG SDI Confidential Proprietary –
Spec. No.
8.8 Warning
ICP663450A Version No. 0.0
Handling Precaution and Prohibitions of Lithium Ion & Lithium Ion Polymer
Rechargeable Cells and Batteries
Inaccurate handling of lithium ion and lithium ion polymer rechargeable battery may cause leakage, heat,
smoke, an explosion, or fire.
This could cause deterioration of performance or failure. Please be sure to follow instructions carefully.
1.1 Storage
Store the battery at low temperature (below 20℃ is recommended), low humidity, no dust and no
corrosive gas atmosphere.
1.2 Safety precaution and prohibitions
To assure product safety, describe the following precautions in the instruction manual of the
application.
[ Danger!]
■ Electrical misusage
Use dedicated charger.
Use or charge the battery only in the dedicated application.
Don't charge the battery by an electric outlet directly or a cigarette lighter charger.
Don't charge the battery reversely.
■ Environmental misusage
Don't leave the battery near the fire or a heated source.
Don't throw the battery into the fire.
Don't leave, charge or use the battery in a car or similar place where inside of temperature may be
over 60℃.
Don't immerse, throw, wet the battery in water / seawater.
■ others
Don't fold the battery cased with laminated film such as pouch and Polymer.
Don't store the battery in a pocket or a bag together with metallic objects such as keys, necklaces,
hairpins, coins, or screws.
Don't short circuit (+) and (-) terminals with metallic object intentionally.
Don't pierce the battery with a sharp object such as a needle, screw drivers.
Don't heat partial area of the battery with heated objects such as soldering iron.
Don't hit with heavy objects such as a hammer, weight.
Don't step on the battery and throw or drop the battery on the hard floor to avoid mechanical shock.
15
Battery Division -SAMSUNG SDI Confidential Proprietary –
Spec. No.
ICP663450A Version No. 0.0
Don't disassemble the battery or modify the battery design including electric circuit.
Don't solder on the battery directly.
Don't use seriously scared or deformed battery.
Don't put the battery into a microwave oven, dryer ,or high-pressure container.
Don't use or assemble the battery with other makers' batteries, different types and/or models of
batteries such as dry batteries, nickel-metal hydride batteries, or nickel-cadmium batteries.
Don't use or assemble old and new batteries together.
[ Warning! ]
Stop charging the battery if charging isn't completed within the specified time.
Stop using the battery if the battery becomes abnormally hot, order, discoloration, deformation, or
abnormal conditions is detected during use, charge, or storage.
Keep away from fire immediately when leakage or foul odors are detected. If liquid leaks onto your
skin or cloths, wash well with fresh water immediately.
If liquid leaking from the battery gets into your eyes, don't rub your eyes and wash them with clean
water and go to see a doctor immediately.
If the terminals of the battery become dirty, wipe with a dry cloth before using the battery.
The battery can be used within the following temperature ranges. Don't exceed these ranges.
Charge temperature ranges : 0℃ ~ 45℃
Discharge Temperature ranges : -20℃ ~ 60℃
Store the battery at temperature below 60℃
Cover terminals with proper insulating tape before disposal.
[ Caution! ]
■ Electrical misusage
Battery must be charge with constant current-constant voltage (CC/CV).
Charge current must be controlled by specified value in Cell specification.
Cut-off Voltage of charging must be 4.2V.
Charger must stop charging battery by detecting either charging time or current specified in Cell’s
specification.
Discharge current must be controlled by specified value in Cell’s specification.
Cut-off Voltage of discharging must be over 2.5V.
16
Battery Division -SAMSUNG SDI Confidential Proprietary –
Spec. No.
■ others
ICP663450A Version No. 0.0
Keep the battery away from babies and children to avoid any accidents such as swallow.
If younger children use the battery, their guardians should explain the proper handling method and
precaution before using.
Before using the battery, be sure to read the user's manual and precaution of it's handling.
Before using charger, be sure to read the user's manual of the charger.
Before installing and removing the battery from application, be sure to read user's manual of the
application.
Replace the battery when using time of battery becomes much shorter than usual.
Cover terminals with insulating tape before proper disposal.
If the battery is needed to be stored for an long period, battery should be removed from the
application and stored in a place where humidity and temperature are low.
While the battery is charged, used and stored, keep it away from object materials with static electric
chargers.
Safety Handling Procedure for the Transporter
■ Quarantine : Packages that are crushed, punctured or torn open to reveal contents should not be
transported. Such packages should be isolated until the shipper has been consulted,
provided instructions and, if appropriate, arranged to have the product inspected and
repacked.
■ Spilled Product : In the event that damage to packaging results in the release of cells or batteries,
the spilled products should be promptly collected and segregated and the shipper
should be contacted for instructions.
Design of positioning the battery pack in application and charger
To prevent the deterioration of the battery performance caused by heat, battery shall be positioned
away from the area where heat is generated in the application and the charger.
Design of the Battery Pack
Be sure adopting proper safe device such as PTC specified type or model in Cell Specification. If you
intend to adopt different safety device which is not specified in Cell Specification, please contact
Samsung SDI to investigate any potential safety problem.
Be sure designing 2nd protective devices such as PTC & PCM at the same time to protect Cell just in
case one protective device is fault.
Please contact following offices when you need any help including safety concerns.
17
Battery Division -SAMSUNG SDI Confidential Proprietary –
Spec. No.
ICP663450A Version No. 0.0
Samsung SDI Emergency Contact Information
■ Samsung SDI Headquarter.
20th Fl., Samsung Life Insurance Bldg. 150, 2-ka, Taepyung-Ro, Chung-Ku, Seoul, Korea 100-720
Tel:(+82)2-727-3686 Fax:(+82)2-727-3689 E-mail: onekim@
■ Samsung SDI Chonan factory.
508, Sungsung-Dong, Chonan City, Chungchongnam-Do, Korea
Tel:(+82)41-624-3669 Fax:(+82)41-624-3697
■ Samsung SDI America office.
18600 Broadwick Street Rancho Dominguez CA 90180
Tel:(+1)310-900-5205 Fax:(+1)310-537-1033
■ Samsung SDI Taiwan office.
Rm. 3010, 30F., 333, Keelung Rd. Sec. 1, Taipei, Taiwan
Tel:(+886)2-2728-8469 Fax:(+886)2-2728-8480
18
Battery Division
2023年12月6日发(作者:黎飞兰)
-SAMSUNG SDI Confidential Proprietary –
Spec. No.
ICP663450A Version No. 0.0
SPECIFICATION OF PRODUCT
SPECIFICATION OF PRODUCT
for Lithium-ion Rechargeable Cell
Model : ICP663450A
Fed. 8th, 2007
Samsung SDI Co.,Ltd.
Battery Division -SAMSUNG SDI Confidential Proprietary –
Spec. No.
ICP663450A Version No. 0.0
SPECIFICATIONS
1. Scope
This product specification has been prepared to specify the rechargeable lithium-ion cell
('cell') to be supplied to the customer by Samsung SDI Co., Ltd.
2. Description and Model
2.1 Description Cell (lithium-ion rechargeable cell)
2.2 Model ICP663450A
3. Nominal Specifications
Item
3.1 Nominal Capacity
3.2 Charging Voltage
3.3 Nominal Voltage
3.4 Charging Method
3.5 Charging Current
3.6 Charging Time
3.7 Max. Charge Current
3.8 Max. Discharge Current
3.9 Discharge Cut-off Voltage
3.10 Cell Weight
3.11 Cell Dimension
3.12 Operating Temperature
3.13 Storage Temperature
Note (1): If the cell is kept as ex-factory status (50~60% of Charge state),
the capacity recovery rate is more than 80%.
Specification
1330mAh (0.2C discharge)
4.2V
3.7V
CC-CV (constant voltage with limited current)
Standard charge: 665mA
Rapid charge: 1330mA
Standard charge: 3hours
Rapid charge: 2.5hours
1330mA
2660mA
2.75V
Max. 28.0g
Thickness: Max. 6.60mm (Initial fully charged cell)
Width: Max. 34.0mm
Height: Max. 50.0mm
Charge : 0 to 45℃
Discharge: –20 to 60℃
1 year : -20~25℃(1*)
3 months : -20~45℃(1*)
1 month : -20~60℃(1*)
1
Battery Division -SAMSUNG SDI Confidential Proprietary –
Spec. No.
ICP663450A Version No. 0.0
4. Outline Dimensions
See the attachment (Fig. 1)
5. Appearance
There shall be no such defects as scratch, rust, discoloration, leakage which
may adversely affect commercial value of the cell.
6. Standard Test Conditions
6.1 Environmental Conditions
Unless otherwise specified, all tests stated in this specification are conducted
at temperature 25±3℃ and humidity 65±20%.
6.2 Measuring Equipment
(1) Ammeter and Voltmeter
The ammeter and voltmeter should have an accuracy of the grade 0.5 or higher.
(2) Slide caliper
The slide caliper should have 0.05 mm scale.
(3) Impedance meter
The impedance meter with AC 1kHz should be used.
7. Characteristics
7.1 Standard Charge
This "Standard Charge" means charging the cell with charge current 665mA
and constant voltage 4.2V at 25℃ for 3hours.
7.2 Rated Charge
This "Rated Charge" means charging the cell with charge current 650mA
and constant voltage 4.2V and 0.05C(=65mA) cut-off at 25℃.
7.3 Standard Discharge Capacity
The standard discharge capacity is the initial discharge capacity of the cell, which is
measured with discharge current of 266mA with 2.75V cut-off at 25℃ within 1 hour
after the standard charge.
Standard Discharge Capacity
≥ 1330mAh
7.4 Rated Discharge Capacity
The rated discharge capacity is the initial discharge capacity of the cell, which is
measured with discharge current of 650mA with 3.2V cut-off at 25℃ within 1 hour
after the rated charge.
Rated Discharge Capacity
≥ 650mAh
2
Battery Division -SAMSUNG SDI Confidential Proprietary –
Spec. No.
ICP663450A Version No. 0.0
7.5 Pulse Discharge
Cell shall be discharged at a constant current rate of 1C to 3.2V.
Cells shall be also discharged per the pulse profile described figure.1 until 3.2V.
Figure 1. Pulse Profile
1.5A80mA0.6ms
4ms
7.6 Initial internal impedance
Initial internal impedance measured at AC 1kHz after rated charge.
Initial internal impedance range of 45
± 15mΩ
7.7 Charge Rate Capabilities
Discharge capacity is measured with constant current 650mA and 3.2V cut-off
after the cell is charged with 4.2V as follows.
Current
Cut-off
0.2C
(260mA)
0.05C
Charge Condition
0.5C
(650mA)
0.05C
1.0C
(1300mA)
0.05C
2.0C
(2600mA)
0.05C
Relative
100% 100% 100% 90%
Capacity
Note: Percentage as an index of the rated discharge capacity (=1300mAh) is 100%.
7.8 Discharge Rate Capabilities
Discharge capacity is measured with the various currents in under table and 3.2V
cut-off after the rated charge.
3
Battery Division -SAMSUNG SDI Confidential Proprietary –
Spec. No.
ICP663450A Version No. 0.0
Current
Relative
Capacity
0.2C
(260mA)
102%
Discharge Condition
0.5C
(650mA)
100%
1.0C
(650mA)
95%
2.0C
(2600mA)
80%
Pulse
100%
Note: Percentage as an index of the rated discharge capacity (=1300mAh) is 100%.
7.9 Temperature Dependence of Discharge Capacity
Capacity comparison at each temperature, measured with discharge
constant current 650mA and 3.2V cut-off after the rated charge is as follows.
Charge Temperature
25℃
Relative Capacity
-20℃
5%
Discharge temperature (0.5C)
-10℃
40%
0℃
80%
25℃
100%
40℃
100%
60℃
90%
Note: If charge temperature and discharge temperature is not the same,
the interval for temperature change is 2 hours.
Percentage as an index of the rated discharge capacity (=1300mAh) is 100%.
Charge Temperature
25℃
Relative Capacity
-20℃
5%
Discharge temperature (Pulse)
-10℃
40%
0℃
80%
25℃
100%
40℃
100%
60℃
90%
7.10 Temperature Dependence of Charge Capacity
Capacity comparison at each temperature, measured with discharge
constant current 650mA and 3.2V cut-off after the rated charge is as follows.
Relative Capacity
Charge temperature
0℃
80%
25℃
100%
40℃
100%
Discharge temperature
25℃
Note: If charge temperature and discharge temperature is not the same,
the interval for temperature change is 2 hours.
Percentage as an index of the rated discharge capacity (=1300mAh) is 100%.
7.10 Cycle Life
Each cycle is an interval between the charge (charge current 1300mA) with
0.05C cut-off and the discharge (discharge current 1300mA) with 3.2V cut-off.
4
Battery Division -SAMSUNG SDI Confidential Proprietary –
Spec. No.
ICP663450A Version No. 0.0
Capacity is measured at 100cycles,300cycles and 500cycles.
100cyc. Capacity
≥ 1170mAh (90% of the rated discharge capacity)
300cyc. Capacity
≥ 1105mAh (85% of the rated discharge capacity)
500cyc. Capacity
≥ 1040mAh (80% of the rated discharge capacity)
7.11 Storage Characteristics
Capacity after storage for 30days at 25℃ after the rated charged measured with
discharge current 650mA with 3.2V cut-off at 25℃.
Capacity retention(after the storage)
≥ 1235mAh (95% of the rated discharge capacity)
8. Mechanical Characteristics
8.1 Drop Test
Test method: Cell(rated charged) is dropped onto the steel plate (thickness≥10mm)
from 1.5m height at each side 3 times and a random direction 2 times.
(Total 20 times)
Criteria: No leakage, Open circuit voltage
≥ 4.0V, IR < 100mΩ
8.2 Vibration Test
Test method: Cell(rated charged) is vibrated only up and down direction
with vibration cycling that consists of 10Hz to 500Hz and 500Hz to 1800Hz
during 45min per each mode (ASD: 0.1g2/Hz, Average Acceleration:
6gRMS) at 25℃±3℃.
Criteria: No leakage, Open circuit voltage
≥ 4.0V, IR < 100mΩ
9. Environmental Characteristics
9.1 Thermal Shock
Test method: Cell(rated charged) is repeatedly tested with 30 times heat cycling, which
means maintaining the cell for 1hours at –40℃ and 85℃ respectively.
Inspect its appearance and measure its thickness right after thermal shock.
Measure the recovered capacity by rated charge/discharge cycling after
rated discharging(650mA, 3.2V cut-off) at 25℃.
Criteria: No leakage, Cell thickness < 7.26mm
Recovery > 1040mAh (80% of the rated discharge capacity)
9.2 Humidity
Test method: Cell(rated charged) is exposed to 50℃,95%RH. for 10days
5
Battery Division -SAMSUNG SDI Confidential Proprietary –
Spec. No.
ICP663450A Version No. 0.0
Inspect appearance and measure thickness right after humidity test.
Measure the recovered capacity by rated charge/discharge cycling after
rated discharging(650mA, 3.2V cut-off) at 25℃.
Criteria: No leakage, Cell thickness < 6.93mm,
Recovery > 1170mAh (90% of the rated discharge capacity)
9.3 Life cycle at low temperature
Repeat 10times of cycles(Discharging first) at 0℃(Charge :1C,4.2V,0.05C cut off,
Discharge: 1C, 3.2V), and measure IR & thickness after 5ycles and 10cycles, after
cycling test, measure the IR & thickness after stand 2hours at 25±3℃.
Criteria: 10cyc. Thickness < 6.93mm
9.4 Low Pressure
Cell(rated charged) is deposited into the vacuum chamber in pressure 11.6kPa for
6hours at 25±3℃, inspect appearance and measure the IR & voltage after test
Criteria: No leakage, Open circuit voltage
≥ 4.0V, IR < 100mΩ
9.5 Abnormal charge
Test method: To charge the rate charged cell to 4.25V, 4.275V and 4.30V and with
constant current of 700mA for 168hours at 25℃.
Criteria: Thickness < 7.10mm
10. Safety
Safety Test shall be performed with the following criteria
- UL1642
- Fully Charged Cell
- No protection component/circuit on the battery cell, i.e. bare cell.
Testing shall be performed at 25℃±3℃.
There should be neither fire nor explosion after testing under the temperature of 200℃.
10.1 Overcharge Test (without PTC)
Test method: To charge the standard charged cell with 5V and 1.0A at 25℃
for 2.5 hours.
Criteria: No fire, and no explosion.
6
Battery Division -SAMSUNG SDI Confidential Proprietary –
Spec. No.
ICP663450A Version No. 0.0
10.2 External Short-circuit Test
Test method: The cell shall be fully charged, it is stored in ambient temperature of 60℃.
Each test sample is short-circuited by connecting positive and negative
terminal with less than 100mΩ wire. And stand for 2.5 hours
Criteria: No smoke, No fire, and no explosion.
10.3 Reverse Charge Test
Test method: To charge reverse the standard charged cell with charge current 1330mA
for 2.5 hours.
Criteria: No fire, and no explosion.
10.4 Nail Penetrating Test
Test method: Cell shall be fully charged. Penetrate completely center of cell with
5mm diameter nail at the velocity of 40mm/sec.
Criteria: No fire, and no explosion.
10.5 Heating Test
Test method: To heat the standard charged cell at heating rate 5℃ per minute up to
150℃ and keep the cell in oven for 60 minutes.
Criteria: No fire, and no explosion within 10min.
10.6 Crush
Test method: To crush the standard charged cell with force of 13kN.
(Crushed side is longitudinal and narrow axis.)
Criteria: No fire, and no explosion.
10.7 Impact
Test method: To place 15.8mm diameter bar across the center of standard charged cell,
and drop 9.1kg weight from 610±25mm height onto the cell.
(Impacted side is longitudinal and wide axis.)
Criteria: No fire, and no explosion.
7
Battery Division -SAMSUNG SDI Confidential Proprietary –
Spec. No.
ICP663450A Version No. 0.0
11. Warranty
Samsung SDI will be responsible for replacing the cell against defects or poor workmanship
for 1year from the date of shipping. Any other problem caused by malfunction of the
equipment or unsuitable use of the cell is not under this warranty.
The warranty set forth in proper using and handling conditions described above and
excludes in the case of a defect which is not related to manufacturing of the cell.
[ Disclaimer ]
This Specification stipulates the final and comprehensive requirements for the respective
products hereof. beyond this Specification, it is the responsibility of the customer to
explicitly disclose any additional requirements, information or reservations regarding these
requirements to Samsung SDI prior to implementation,
where any and all disclosures of the customer shall be with an authorized representative of
Samsung SDI in writing.
Samsung SDI shall not be responsible for safety, performance, functionality or compatibility
of the system with which the Samsung SDI-supplied components are integrated unless
such features have been expressly communicated and described in the Specification.
SAMSUNG SDI MAKES NO GUARANTY OR WARRANTY, EXPRESS OR IMPLIED,
INCLUDING BUT NOT LIMITED TO MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE, TO ANY PARTY.
Moreover, any party should do their own due diligence regarding these requirements prior
to implementation.
12. Others
12.1 Storage for a long time
If the cell is kept for a long time(3months or more), It is strongly recommended
that the cell is preserved at dry and low-temperature.
12.2 PTC (Positive Temperature Coefficient)
The recommended PTC model : RayChem(Japan), VTP175LF MXP190S, and
Polytronics (Japan), SLD190VF
The max. discharge current of cell with PTC depends on temperature.
12.3 Other
Any matters that specifications does not have, should be conferred with
between the both parties.
8
Battery Division -SAMSUNG SDI Confidential Proprietary –
Spec. No.
ICP663450A Version No. 0.0
Fig.1. ICP663450A
EX-Factory status 6.35mm +0/-0.3
Initial Full Charge status Max 6.60mm
9
Battery Division -SAMSUNG SDI Confidential Proprietary –
Spec. No.
ICP663450A Version No. 0.0
Proper Use and Handling of Lithium Ion Cells
See before using lithium-ion cell
Supplied by Samsung SDI Co., Ltd.
1. General
This document has been prepared to describe the appropriate cautions and
prohibitions, which the customer should take or employ when the customer uses
and handles the lithium ion cell to be manufactured and supplied by Samsung SDI Co.,
Ltd., in order to obtain optimum performance and safety.
2. Charging
2.1 Charging current
Charging current should be less than maximum charge current specified in the product
specification.
2.2 Charging voltage
Charging should be done by voltage less than that specified in the product specification.
2.3 Charging time
Continuous charging under appropriate voltage does not cause any loss of
characteristics. However, the charge timer is recommended to be installed from a safety
consideration, which shuts off further charging at time specified in the product
specification.
2.4 Charging temperature
The cell should be charged within a range of specified temperatures in the product
specification.
2.5 Reverse charging
The cell should be connected, confirming that its poles are correctly aligned.
Inverse charging should be strictly prohibited. If the cell is connected improperly,
it may be damaged.
3. Discharging
3.1 Discharging
3.1.1 The cell should be discharged at less than maximum discharge current
specified in the product specification.
10
Battery Division -SAMSUNG SDI Confidential Proprietary –
Spec. No.
ICP663450A Version No. 0.0
3.2 Discharging temperature
3.2.1 The cell should be discharged within a range of temperatures specified in
the product specification.
3.2.2 Otherwise, it may cause loss of characteristics.
3.3 Over-discharging
3.3.1 The system should equip with a device to prevent further discharging
exceeding discharging cut-off voltage specified in the product
specification.(over-discharging)
3.3.2 Over-discharging may cause loss of performance, characteristics, of
battery function.
3.3.3 Over-discharging may occur by self-discharge if the battery is left for
a very long time without any use.
3.3.4 The charger should equip with a device to detect cell voltage and to
determine recharging procedures.
4. Storage
4.1 Storage conditions
4.1.1 The cell should be stored within a range of temperatures specified
in the product specification.
4.1.2 Otherwise, it may cause loss of characteristics, leakage and/or rust.
4.2 Long-term storage
4.2.1 The cell should be used within a short period after charging because
long-term storage may cause loss of capacity by self-discharging.
4.2.2. If long-term storage is necessary, the cell should be stored at lower
voltage within a range specified in the product specification, because
storage at higher voltage may cause loss of characteristics.
5. Cycle life
5.1 Cycle life performance
5.1.1 The cell can be charged/discharged repeatedly up to times specified in
the produce specification with a certain level of capacity also specified
in the product specification.
5.1.2 Cycle life may be determined by conditions of charging, discharging,
operating temperature and/or storage.
11
Battery Division -SAMSUNG SDI Confidential Proprietary –
Spec. No.
ICP663450A Version No. 0.0
6. Design of System
6.1 Connection between the cell and the battery
6.1.1 The cell should not be soldered directly with leads. Namely, the cell
should be welded with leads on its terminal and then be soldered with
wire or leads to soldered lead.
6.1.2 Otherwise, it may cause damage of component, such as separator and
insulator, by heat generation.
6.2 Positioning the battery in the System
6.2.1 The battery should be positioned as possible as far from heat sources
and high temperature components.
6.2.2 Otherwise, it may cause loss of characteristics.
6.3 Mechanical shock protection of the battery
6.3.1 The battery should equip with appropriate shock absorbers in order to
minimize shock.
6.3.2 Otherwise, it may cause shape distortion, leakage, heat generation
and/or rupture.
6.4 Short-circuit protection of the cell
6.4.1 The cell equips with an insulating sleeve to protect short-circuit which
may occur during transportation, battery assembly and /or system
operation.
6.4.2 If the cell sleeve is damaged by some cause such as outside impact,
it may cause short-circuit with some wiring inside the battery.
6.5 Connection between the battery and charger/system
6.5.1 The battery should be designed to be connected only to the specified
charger and system.
6.5.2 A reverse connection of the battery, even in the specified system,
should be avoided by employing special battery design such as
a special terminals.
7. Battery Pack Assembly
7.1 Prohibition of usage of damaged cell
7.1.1 The cell should be inspected visually before battery assembly.
7.1.2 The cell should not be used if sleeve-damage, can-distortion and/or
electrolyte-smell is detected.
12
Battery Division -SAMSUNG SDI Confidential Proprietary –
Spec. No.
ICP663450A Version No. 0.0
7.2 Terminals handling
7.2.1 Excessive force on the negative terminal should be avoided when
external lead is welled.
7.3 Transportation
7.3.1 If the cell is necessary to transported to order place, such as the
battery manufacturer, careful precautions should be taken to avoid
damage of cell.
8. Others
8.1 Disassembly
8.1.1 The cell should not be dismantled from the battery pack.
8.1.2 Internal short-circuit caused by disassembly may lead to heat generation
and/or venting.
8.1.3 When the electrolyte is coming in contact with the skin or eyes,
flush immediately with fresh water and seek medical advice.
8.2 Short-circuiting
8.2.1 Short-circuit results in very high current which leads to heat generation.
8.2.3 An appropriate circuitry should be employed to protect accidental
short-circuiting.
8.3 Incineration
8.3.1 Incinerating and disposing of the cell in fire are strictly prohibited,
because it may cause rupture.
8.4 Immersion
8.4.1 Soaking the cell in water is strictly prohibited, because it may cause
melt of components to damaged to functions.
8.5 Mixing use
8.5.1 Different types of cell, or same types but different manufacturer's cell
may lead to cell rupture or damage to system due to the different
characteristics of cell.
8.6 Battery exchange
8.6.1 Although the cell contains no environmentally hazardous component,
such as lead or cadmium. the battery should be disposed according to
the local regulations when it is disposed.
13
Battery Division -SAMSUNG SDI Confidential Proprietary –
Spec. No.
ICP663450A Version No. 0.0
8.6.2 The cell should be disposed with a discharged state to avoid heat generation
by an inadvertent short-circuit.
8.7 Caution
"The Battery used in this device may present a risk of fire or chemical burn if mistreated.
Do not disassemble, heat above 100℃ or incinerate. Replace battery with Samsung
SDI battery only. Use of another battery may present a risk of fire or explosion.
Dispose of used battery promptly. Keep away from children. Do not disassemble and do
not dispose of in fire."
14
Battery Division -SAMSUNG SDI Confidential Proprietary –
Spec. No.
8.8 Warning
ICP663450A Version No. 0.0
Handling Precaution and Prohibitions of Lithium Ion & Lithium Ion Polymer
Rechargeable Cells and Batteries
Inaccurate handling of lithium ion and lithium ion polymer rechargeable battery may cause leakage, heat,
smoke, an explosion, or fire.
This could cause deterioration of performance or failure. Please be sure to follow instructions carefully.
1.1 Storage
Store the battery at low temperature (below 20℃ is recommended), low humidity, no dust and no
corrosive gas atmosphere.
1.2 Safety precaution and prohibitions
To assure product safety, describe the following precautions in the instruction manual of the
application.
[ Danger!]
■ Electrical misusage
Use dedicated charger.
Use or charge the battery only in the dedicated application.
Don't charge the battery by an electric outlet directly or a cigarette lighter charger.
Don't charge the battery reversely.
■ Environmental misusage
Don't leave the battery near the fire or a heated source.
Don't throw the battery into the fire.
Don't leave, charge or use the battery in a car or similar place where inside of temperature may be
over 60℃.
Don't immerse, throw, wet the battery in water / seawater.
■ others
Don't fold the battery cased with laminated film such as pouch and Polymer.
Don't store the battery in a pocket or a bag together with metallic objects such as keys, necklaces,
hairpins, coins, or screws.
Don't short circuit (+) and (-) terminals with metallic object intentionally.
Don't pierce the battery with a sharp object such as a needle, screw drivers.
Don't heat partial area of the battery with heated objects such as soldering iron.
Don't hit with heavy objects such as a hammer, weight.
Don't step on the battery and throw or drop the battery on the hard floor to avoid mechanical shock.
15
Battery Division -SAMSUNG SDI Confidential Proprietary –
Spec. No.
ICP663450A Version No. 0.0
Don't disassemble the battery or modify the battery design including electric circuit.
Don't solder on the battery directly.
Don't use seriously scared or deformed battery.
Don't put the battery into a microwave oven, dryer ,or high-pressure container.
Don't use or assemble the battery with other makers' batteries, different types and/or models of
batteries such as dry batteries, nickel-metal hydride batteries, or nickel-cadmium batteries.
Don't use or assemble old and new batteries together.
[ Warning! ]
Stop charging the battery if charging isn't completed within the specified time.
Stop using the battery if the battery becomes abnormally hot, order, discoloration, deformation, or
abnormal conditions is detected during use, charge, or storage.
Keep away from fire immediately when leakage or foul odors are detected. If liquid leaks onto your
skin or cloths, wash well with fresh water immediately.
If liquid leaking from the battery gets into your eyes, don't rub your eyes and wash them with clean
water and go to see a doctor immediately.
If the terminals of the battery become dirty, wipe with a dry cloth before using the battery.
The battery can be used within the following temperature ranges. Don't exceed these ranges.
Charge temperature ranges : 0℃ ~ 45℃
Discharge Temperature ranges : -20℃ ~ 60℃
Store the battery at temperature below 60℃
Cover terminals with proper insulating tape before disposal.
[ Caution! ]
■ Electrical misusage
Battery must be charge with constant current-constant voltage (CC/CV).
Charge current must be controlled by specified value in Cell specification.
Cut-off Voltage of charging must be 4.2V.
Charger must stop charging battery by detecting either charging time or current specified in Cell’s
specification.
Discharge current must be controlled by specified value in Cell’s specification.
Cut-off Voltage of discharging must be over 2.5V.
16
Battery Division -SAMSUNG SDI Confidential Proprietary –
Spec. No.
■ others
ICP663450A Version No. 0.0
Keep the battery away from babies and children to avoid any accidents such as swallow.
If younger children use the battery, their guardians should explain the proper handling method and
precaution before using.
Before using the battery, be sure to read the user's manual and precaution of it's handling.
Before using charger, be sure to read the user's manual of the charger.
Before installing and removing the battery from application, be sure to read user's manual of the
application.
Replace the battery when using time of battery becomes much shorter than usual.
Cover terminals with insulating tape before proper disposal.
If the battery is needed to be stored for an long period, battery should be removed from the
application and stored in a place where humidity and temperature are low.
While the battery is charged, used and stored, keep it away from object materials with static electric
chargers.
Safety Handling Procedure for the Transporter
■ Quarantine : Packages that are crushed, punctured or torn open to reveal contents should not be
transported. Such packages should be isolated until the shipper has been consulted,
provided instructions and, if appropriate, arranged to have the product inspected and
repacked.
■ Spilled Product : In the event that damage to packaging results in the release of cells or batteries,
the spilled products should be promptly collected and segregated and the shipper
should be contacted for instructions.
Design of positioning the battery pack in application and charger
To prevent the deterioration of the battery performance caused by heat, battery shall be positioned
away from the area where heat is generated in the application and the charger.
Design of the Battery Pack
Be sure adopting proper safe device such as PTC specified type or model in Cell Specification. If you
intend to adopt different safety device which is not specified in Cell Specification, please contact
Samsung SDI to investigate any potential safety problem.
Be sure designing 2nd protective devices such as PTC & PCM at the same time to protect Cell just in
case one protective device is fault.
Please contact following offices when you need any help including safety concerns.
17
Battery Division -SAMSUNG SDI Confidential Proprietary –
Spec. No.
ICP663450A Version No. 0.0
Samsung SDI Emergency Contact Information
■ Samsung SDI Headquarter.
20th Fl., Samsung Life Insurance Bldg. 150, 2-ka, Taepyung-Ro, Chung-Ku, Seoul, Korea 100-720
Tel:(+82)2-727-3686 Fax:(+82)2-727-3689 E-mail: onekim@
■ Samsung SDI Chonan factory.
508, Sungsung-Dong, Chonan City, Chungchongnam-Do, Korea
Tel:(+82)41-624-3669 Fax:(+82)41-624-3697
■ Samsung SDI America office.
18600 Broadwick Street Rancho Dominguez CA 90180
Tel:(+1)310-900-5205 Fax:(+1)310-537-1033
■ Samsung SDI Taiwan office.
Rm. 3010, 30F., 333, Keelung Rd. Sec. 1, Taipei, Taiwan
Tel:(+886)2-2728-8469 Fax:(+886)2-2728-8480
18
Battery Division