最新消息: USBMI致力于为网友们分享Windows、安卓、IOS等主流手机系统相关的资讯以及评测、同时提供相关教程、应用、软件下载等服务。

ASUS A55BM-A USB3 ii T8663 第二版 2013 年 9 月发行手册说明书_百

IT圈 admin 78浏览 0评论

2024年7月14日发(作者:法思萱)

SINUMERIK

SINUMERIK Integrate for Production

Valid for

840D sl under Operate 4.7 SP3

828D under Operate 4.7 SP3

Supplementary conditions and notes on

reloading HMI archives

Version Nov. 12, 2015

Readme file

© Siemens AG 2016

All rights reserved

DF MC TTI T&E 2

Page 1 of 6

Notes for installation and use

These notes take priority over statements made in other documents.

Please read the notes carefully because they contain important information for installation and use of

SINUMERIK Integrate for Production.

The SINUMERIK Integrate for Production software is called SIP in the following.

Please read these notes before the installation.

Activation and enabling of the SIP components under

SINUMERIK Operate for 828D and 840D sl

After an Operate update of software version 4.5 SP3 (or higher) or a new installation of software version

4.7 SP3 for the 840D sl or software version 4.7 SP3 for the 828D, the required SIP components are

already available in SINUMERIK Operate, but still have to be activated and enabled. Only then are the

SIP functionalities available.

Please read the SIP Installation Manual which describes how SIP is activated and enabled under

SINUMERIK Operate.

© Siemens AG 2016

All rights reserved

DF MC TTI T&E 2

Page 2 of 6

Notes and supplementary conditions when reloading HMI

archives for the 840D sl under Linux

Under Linux during an update to software version 4.7 SP3

Precondition: HMI archive has been created in a software version as of 4.5 SP3

Assumption: Software update under Linux as of 4.5 SP3 to software version 4.7 SP3 has been

performed. Reload of an HMI archive which has been created in a software version as of 4.5 SP3.

Note: All SIP products, SIP Operate clients and SIP-specific softkeys are available again after reloading

the HMI archive.

1. After reloading the HMI archive, please restart the HMI.

2. After this, settings in the , or

my have to be imported from the epsconfig.*.d or be re-edited (parameters such as

URLs, logging, etc.). This is only the case, however, if these files epsconfig.*.d are

available.

3. BaseSetup should be reinstalled. (Uninstallation and installation).

4. Finally, restart the HMI.

Under Linux during a new installation of software version 4.7 SP3 using the "Full Restore"

function

Precondition: HMI archive has been created in a software version as of 4.5 SP3

Assumption: New installation of software version 4.7 SP3 and subsequent reloading of the HMI archive.

HMI restart has been performed after the reload.

Note: If SIP products and SIP functionalities were activated when the HMI archive was created, they are

available after the reload when the following adaptations have ben made.

1. After reloading the HMI archive, please restart the HMI.

2. After this, settings in the , or

my have to be imported from the epsconfig.*.d or be re-edited (parameters such as

URLs, logging, etc.). This is only the case, however, if these files epsconfig.*.d are

available.

3. Then you must uninstall all clients (MMT, MMP, BaseSetup, etc.). HMI restarts are required in

between. Uninstallation can be found under SoftKey App installation.

4. Uninstall the "" and restart the HMI again

5. Install the "" and install the "" with the "App Installation" softkey

6. Finally, restart the HMI.

7. If necessary, install the Operate clients (e.g. for MMT, MMP & AMP) individually and restart the

HMI after each Operate client installation.

It is recommended that you create an HMI archive in software version 4.7 SP3 if further new installations

based on 4.7 SP3 with customer-specific SIP adaptations are planned.

© Siemens AG 2016

All rights reserved

DF MC TTI T&E 2

Page 3 of 6

Notes and supplementary conditions when reloading HMI

archives for the 840D sl under Windows

Under Windows during an update to software version 4.7 SP3

Precondition: HMI archive has been created in a software version as of 4.5 SP3

Assumption: Software update under Windows as of 4.5 SP3 to software version 4.7 SP3 has been

performed. Reloading of an HMI archive which has been created in a software version 4.5 SP3 (or

higher).

Note: All SIP products, SIP Operate clients and SIP-specific customer adaptations and softkeys are

available again after the reload.

1. After reloading the HMI archive, please restart the HMI.

2. After this, settings in the , or

my have to be imported from the epsconfig.*.d or be re-edited (parameters such as

URLs, logging, etc.). This is only the case, however, if these files epsconfig.*.d are

available.

3. BaseSetup should be reinstalled. (Uninstallation and installation).

4. Finally, restart the HMI.

Under Windows during a new installation of software version 4.7 SP3

Precondition: HMI archive has been created in a software version as of 4.5 SP3

Assumption: New installation of software version 4.7 SP3 and subsequent reloading of the HMI archive.

HMI restart has been performed after reloading the archive.

Note: If SIP products and SIP functionalities were activated when the HMI archive was created, they are

available again after the reload when the following adaptations have been made.

1. After reloading the HMI archive, please restart the HMI.

2. After this, settings in the , or my

have to be imported from the epsconfig.*.d or be re-edited (parameters such as URLs,

logging, etc.). This is only the case, however, if these files epsconfig.*.d are available.

3. Then you must uninstall all clients (MMT, MMP, BaseSetup, etc.). HMI restarts are required in

between. Uninstallation can be found under SoftKey App installation.

4. Then uninstall "". During the uninstallation the following error message appears,

"Cannot remove file: F:/hmisl/addon/sinumerik/hmi/lnginstaller_".

5. Restart the HMI and restart the uninstallation of the "".

6. Restart the HMI again

7. Install ""

8. Select and install the "" setup file with the "App Installation" softkey

9. Restart the HMI again

10. Install the Operate clients (e.g. for MMT, MMP & AMP) individually and restart the HMI after each

Operate client installation

(Information on the installation of the Operate clients can be found in the SIP Installation Manual)

It is recommended that you create an HMI archive in software version 4.7 SP3 if further new installations

based on 4.7 SP3 with customer-specific SIP adaptations are planned.

© Siemens AG 2016

All rights reserved

DF MC TTI T&E 2

Page 4 of 6

Notes and supplementary conditions when reloading HMI

archives for the 828D under Linux

Under Linux during a new installation of software version 4.7 SP3 using the "Full Restore"

function

Precondition: HMI archive has been created in a software version as of 4.5 SP3

Assumption: New installation of software version 4.7 SP3 and subsequent reloading of the HMI archive.

HMI restart has been performed after reloading the archive.

Note: The customer-specific SIP adaptations are available again after reloading the HMI archive under

SINUMERIK Operate 4.7 SP3.

Supplementary condition:

ID Title Supplementary condition Description

Workaround

374835 Sporadic HMI In the SlTrc If the options (trace bits) of the In the SlTrc

crash with (HMI trace), ePSJsDialog module are activated for (HMI trace), the

activated the options the trace on the control in the SlTrc options (trace

SlTrace of the (trace bits) (HMI trace) for analysis purposes, the bits) must be

ePSJsDialog must not be HMI Operate may crash if certain deactivated for

module activated for characters occur at a specific position in the ePSJsDialog

the the trace output. As long as the module. In the

ePSJsDialog ePSJsDialog module remains inactive, initial state (after

module. the SlTrace can be used as usual. installation of

the SINUMERIK

Operate), these

options are

deactivated.

430468 MMT 2.7 - HMI When an The reloading of an HMI archive on a After pressing

archive HMI archive PCU after a Sinumerik Operate Update Skip softkey, the

reloading on is reloaded, is erroneous: Some files cannot be reloading of the

PCU after error overwritten. archive is

SinOp update is messages carried out

erroneous: must be without errors.

Some files acknowledge

cannot be d manually.

overwritten

430089 "Backup data" Backup data "Backup data" softkey no longer It will function

softkey does not softkey only functions after the update of Sinumerik again after you

function after functions Operate 4.7.1.1 to 4.7.2.1. Softkey uninstall and re-

update from after the exists but has no function. install the

SINOP4711 to installer and installer/base

4721 base are re-setup.

installed.

425374 SinInt - the Without an After the

If no connection exists from the PCU

SINint softkey is HMI restart,

(Windows XP) to an NCU, the HMI must

activation of the

only active on the Sinumerik

be restarted so that the Sinumerik

© Siemens AG 2016

All rights reserved

DF MC TTI T&E 2

Page 5 of 6

Windows XP

after an HMI

restart

425512 If usage is

blocked, the

user can assign

but not resign in

the "User

menu".

Sinumerik

Integrate softkey is available.

Integrate

softkey is not

available.

If the use of

Sinumerik

Integrate is

deactivated

("Block

usage"

softkey), then

the "User

menu" dialog

should not be

used.

User menu dialog cannot be used when

Sinumerik Integrate is deactivated,

because it is no longer possible to exit

this dialog. A changeover outside of

Sinumerik Integrate is possible,

however.

Integrate via the

machine data,

the HMI must be

restarted.

If the User menu

is nevertheless

activated when

usage is

blocked, the

machine dialog

can be re-

activated with

F10 + F1.

Sinumerik

Integrate can

only be

activated and

used after an

HMI restart.

Download of an

IBN archive from

the SIP server

directly to a USB

stick. This

archive can then

be installed

directly on a

machine via

Sinumerik

Operate.

430907

AMB - HMI

archive cannot

be read-in by

SinIntClient

Occasionally,

large IBN

archives are

not

completely

transferred

from the SIP

server to a

machine.

Large IBN archives (approx. > 1 MB)

occasionally cannot be downloaded

from the server via the Sinumerik

Integrate client and installed without

errors.

© Siemens AG 2016

All rights reserved

DF MC TTI T&E 2

Page 6 of 6

2024年7月14日发(作者:法思萱)

SINUMERIK

SINUMERIK Integrate for Production

Valid for

840D sl under Operate 4.7 SP3

828D under Operate 4.7 SP3

Supplementary conditions and notes on

reloading HMI archives

Version Nov. 12, 2015

Readme file

© Siemens AG 2016

All rights reserved

DF MC TTI T&E 2

Page 1 of 6

Notes for installation and use

These notes take priority over statements made in other documents.

Please read the notes carefully because they contain important information for installation and use of

SINUMERIK Integrate for Production.

The SINUMERIK Integrate for Production software is called SIP in the following.

Please read these notes before the installation.

Activation and enabling of the SIP components under

SINUMERIK Operate for 828D and 840D sl

After an Operate update of software version 4.5 SP3 (or higher) or a new installation of software version

4.7 SP3 for the 840D sl or software version 4.7 SP3 for the 828D, the required SIP components are

already available in SINUMERIK Operate, but still have to be activated and enabled. Only then are the

SIP functionalities available.

Please read the SIP Installation Manual which describes how SIP is activated and enabled under

SINUMERIK Operate.

© Siemens AG 2016

All rights reserved

DF MC TTI T&E 2

Page 2 of 6

Notes and supplementary conditions when reloading HMI

archives for the 840D sl under Linux

Under Linux during an update to software version 4.7 SP3

Precondition: HMI archive has been created in a software version as of 4.5 SP3

Assumption: Software update under Linux as of 4.5 SP3 to software version 4.7 SP3 has been

performed. Reload of an HMI archive which has been created in a software version as of 4.5 SP3.

Note: All SIP products, SIP Operate clients and SIP-specific softkeys are available again after reloading

the HMI archive.

1. After reloading the HMI archive, please restart the HMI.

2. After this, settings in the , or

my have to be imported from the epsconfig.*.d or be re-edited (parameters such as

URLs, logging, etc.). This is only the case, however, if these files epsconfig.*.d are

available.

3. BaseSetup should be reinstalled. (Uninstallation and installation).

4. Finally, restart the HMI.

Under Linux during a new installation of software version 4.7 SP3 using the "Full Restore"

function

Precondition: HMI archive has been created in a software version as of 4.5 SP3

Assumption: New installation of software version 4.7 SP3 and subsequent reloading of the HMI archive.

HMI restart has been performed after the reload.

Note: If SIP products and SIP functionalities were activated when the HMI archive was created, they are

available after the reload when the following adaptations have ben made.

1. After reloading the HMI archive, please restart the HMI.

2. After this, settings in the , or

my have to be imported from the epsconfig.*.d or be re-edited (parameters such as

URLs, logging, etc.). This is only the case, however, if these files epsconfig.*.d are

available.

3. Then you must uninstall all clients (MMT, MMP, BaseSetup, etc.). HMI restarts are required in

between. Uninstallation can be found under SoftKey App installation.

4. Uninstall the "" and restart the HMI again

5. Install the "" and install the "" with the "App Installation" softkey

6. Finally, restart the HMI.

7. If necessary, install the Operate clients (e.g. for MMT, MMP & AMP) individually and restart the

HMI after each Operate client installation.

It is recommended that you create an HMI archive in software version 4.7 SP3 if further new installations

based on 4.7 SP3 with customer-specific SIP adaptations are planned.

© Siemens AG 2016

All rights reserved

DF MC TTI T&E 2

Page 3 of 6

Notes and supplementary conditions when reloading HMI

archives for the 840D sl under Windows

Under Windows during an update to software version 4.7 SP3

Precondition: HMI archive has been created in a software version as of 4.5 SP3

Assumption: Software update under Windows as of 4.5 SP3 to software version 4.7 SP3 has been

performed. Reloading of an HMI archive which has been created in a software version 4.5 SP3 (or

higher).

Note: All SIP products, SIP Operate clients and SIP-specific customer adaptations and softkeys are

available again after the reload.

1. After reloading the HMI archive, please restart the HMI.

2. After this, settings in the , or

my have to be imported from the epsconfig.*.d or be re-edited (parameters such as

URLs, logging, etc.). This is only the case, however, if these files epsconfig.*.d are

available.

3. BaseSetup should be reinstalled. (Uninstallation and installation).

4. Finally, restart the HMI.

Under Windows during a new installation of software version 4.7 SP3

Precondition: HMI archive has been created in a software version as of 4.5 SP3

Assumption: New installation of software version 4.7 SP3 and subsequent reloading of the HMI archive.

HMI restart has been performed after reloading the archive.

Note: If SIP products and SIP functionalities were activated when the HMI archive was created, they are

available again after the reload when the following adaptations have been made.

1. After reloading the HMI archive, please restart the HMI.

2. After this, settings in the , or my

have to be imported from the epsconfig.*.d or be re-edited (parameters such as URLs,

logging, etc.). This is only the case, however, if these files epsconfig.*.d are available.

3. Then you must uninstall all clients (MMT, MMP, BaseSetup, etc.). HMI restarts are required in

between. Uninstallation can be found under SoftKey App installation.

4. Then uninstall "". During the uninstallation the following error message appears,

"Cannot remove file: F:/hmisl/addon/sinumerik/hmi/lnginstaller_".

5. Restart the HMI and restart the uninstallation of the "".

6. Restart the HMI again

7. Install ""

8. Select and install the "" setup file with the "App Installation" softkey

9. Restart the HMI again

10. Install the Operate clients (e.g. for MMT, MMP & AMP) individually and restart the HMI after each

Operate client installation

(Information on the installation of the Operate clients can be found in the SIP Installation Manual)

It is recommended that you create an HMI archive in software version 4.7 SP3 if further new installations

based on 4.7 SP3 with customer-specific SIP adaptations are planned.

© Siemens AG 2016

All rights reserved

DF MC TTI T&E 2

Page 4 of 6

Notes and supplementary conditions when reloading HMI

archives for the 828D under Linux

Under Linux during a new installation of software version 4.7 SP3 using the "Full Restore"

function

Precondition: HMI archive has been created in a software version as of 4.5 SP3

Assumption: New installation of software version 4.7 SP3 and subsequent reloading of the HMI archive.

HMI restart has been performed after reloading the archive.

Note: The customer-specific SIP adaptations are available again after reloading the HMI archive under

SINUMERIK Operate 4.7 SP3.

Supplementary condition:

ID Title Supplementary condition Description

Workaround

374835 Sporadic HMI In the SlTrc If the options (trace bits) of the In the SlTrc

crash with (HMI trace), ePSJsDialog module are activated for (HMI trace), the

activated the options the trace on the control in the SlTrc options (trace

SlTrace of the (trace bits) (HMI trace) for analysis purposes, the bits) must be

ePSJsDialog must not be HMI Operate may crash if certain deactivated for

module activated for characters occur at a specific position in the ePSJsDialog

the the trace output. As long as the module. In the

ePSJsDialog ePSJsDialog module remains inactive, initial state (after

module. the SlTrace can be used as usual. installation of

the SINUMERIK

Operate), these

options are

deactivated.

430468 MMT 2.7 - HMI When an The reloading of an HMI archive on a After pressing

archive HMI archive PCU after a Sinumerik Operate Update Skip softkey, the

reloading on is reloaded, is erroneous: Some files cannot be reloading of the

PCU after error overwritten. archive is

SinOp update is messages carried out

erroneous: must be without errors.

Some files acknowledge

cannot be d manually.

overwritten

430089 "Backup data" Backup data "Backup data" softkey no longer It will function

softkey does not softkey only functions after the update of Sinumerik again after you

function after functions Operate 4.7.1.1 to 4.7.2.1. Softkey uninstall and re-

update from after the exists but has no function. install the

SINOP4711 to installer and installer/base

4721 base are re-setup.

installed.

425374 SinInt - the Without an After the

If no connection exists from the PCU

SINint softkey is HMI restart,

(Windows XP) to an NCU, the HMI must

activation of the

only active on the Sinumerik

be restarted so that the Sinumerik

© Siemens AG 2016

All rights reserved

DF MC TTI T&E 2

Page 5 of 6

Windows XP

after an HMI

restart

425512 If usage is

blocked, the

user can assign

but not resign in

the "User

menu".

Sinumerik

Integrate softkey is available.

Integrate

softkey is not

available.

If the use of

Sinumerik

Integrate is

deactivated

("Block

usage"

softkey), then

the "User

menu" dialog

should not be

used.

User menu dialog cannot be used when

Sinumerik Integrate is deactivated,

because it is no longer possible to exit

this dialog. A changeover outside of

Sinumerik Integrate is possible,

however.

Integrate via the

machine data,

the HMI must be

restarted.

If the User menu

is nevertheless

activated when

usage is

blocked, the

machine dialog

can be re-

activated with

F10 + F1.

Sinumerik

Integrate can

only be

activated and

used after an

HMI restart.

Download of an

IBN archive from

the SIP server

directly to a USB

stick. This

archive can then

be installed

directly on a

machine via

Sinumerik

Operate.

430907

AMB - HMI

archive cannot

be read-in by

SinIntClient

Occasionally,

large IBN

archives are

not

completely

transferred

from the SIP

server to a

machine.

Large IBN archives (approx. > 1 MB)

occasionally cannot be downloaded

from the server via the Sinumerik

Integrate client and installed without

errors.

© Siemens AG 2016

All rights reserved

DF MC TTI T&E 2

Page 6 of 6

发布评论

评论列表 (0)

  1. 暂无评论