2024年9月29日发(作者:释芳润)
Oscilloscope
OX 9000 SERIES
isolated channels
4-in-1 Instrument
Oscilloscope
Multimeter
Analyzer
Logger
with the recorded files directly
viewable on screen
Safety
• All channels isolated from one another
and from the earth, 600V CAT III
Ergonomic
• Modern, high tech design which is
simple, compact and practical
Optimization
• of all tools; communication, storage
and operation
Our products are backed by over 125 years of experience in test and measurement
equipment, and encompass the latest international standards for quality and safety.
(800) 343-1391
ERGONOMICS
Designed to simplify use with one button access to most functions
In a housing tailor-made to be as compact as possible,
the mechanical design makes it possible to integrate
the hardware components in a small size with the
keypad benefits from new technology developed in
the automotive industry.
IP
54
Original
CHANNEL AND PARAMETER IDENTIFICATION
Each channel and related parameters are identified with identical
color against a black background for simpler, quicker viewing.
EASY ACCESS VIA TOUCH SCREEN
Intuitive icons are provided to facilitate their use, even with gloves on.
ADJUSTABLE STRAP
This helps to optimize operation of the oscilloscope in your hand
or on your shoulder when working in the field.
A stand is also available to vary the orientation of the oscilloscope
when it is placed on a bench. The oscilloscope can be safely left
unattended using the Kensington locking system.
NEW KEYPAD DESIGN FOR OPTIMUM USER COMFORT
Configuration and measurement displays are simple to access from
the front panel in one of these 5 specific areas: Utilities (brightness,
full screen, screenshot), Measurements, Vertical, Horizontal, Trigger.
LINE POWER OR LI-ION BATTERY
Port on left side.
Scope in carrying case with shoulder strap, set of two 5 ft color-coded leads, alligator clips
and test probes, 10 ft USB cable, µSD memory card, 1-PROBIX Banana Plug Adapter, 1 styli
pen, LI-ION 5.8 Ah battery pack, PA40W-2 power adapter with 110V power cord. Additional
accessories may be model dependent.
2 Technical Assistance (800) 343-1391
APPLICATIONS
Ideal for electronic and industrial maintenance
Electronic maintenance
The OX 9304 model is ideal for electronics with its
300 MHz bandwidth, 4 x 600V CAT III isolated channels,
advanced trigger functions, integrated FFT function,
complex mathematical calculations on the curves, automatic
measurements on 4 channels and the built-in WEB server.
IP54
Housing protected against dust and water spray.
7" WVGA WIDE COLOR TFT TOUCH SCREEN
Makes it easy to view and read the measurements clearly.
It also provides a screen resolution of 800 x 480 dpi with manual
or automatic brightness.
TOUCH-SCREEN STYLUS STORAGE
Among the essential tools available, the sylus is equipped with a
hook for the addition of a cord to make it captive, as required. One
end is slightly flattened to prevent rolling when placed on a table
or bench.
AUTOSET BUTTON
Quickly and effortlessly adjusts the horizontal and vertical;
sensitivity and scales to provide the best resolution.
Industrial maintenance
The OX 9304’s large 7-inch screen, 300 MHz bandwidth,
4 x 600V CAT III isolated channels and Harmonic
Analyzer and Multimeter modes make it ideal for
industrial maintenance applications.
DIRECT SETTING AND SET-UP BUTTONS
COMMUNICATION INTERFACES
These are isolated from one another and from the measurement
channels. A dedicated compartment on the right side protected
by a flexible cover contains all the different communication
interface ports:
•
USB host for communication with a PC
•
wired RJ45 or WiFi for communication with a PC or
•
µSD card for data storage with quick transfer and for
upgrading of the instrument's firmware
printing via a network printer
DIRECT ACCESS ZOOM BUTTON
Channels are isolated.
CATALOG NO. DESCRIPTION
2150.31 ....................................................................................................................................Hand-Held Oscilloscope Model OX 9062 IV 60MHz
2150.32 ..................................................................................................................................Hand-Held Oscilloscope Model OX 9102 IV 100MHz
2150.33 ..................................................................................................................................Hand-Held Oscilloscope Model OX 9104 IV 100MHz
2150.34 ..................................................................................................................................Hand-Held Oscilloscope Model OX 9304 IV 300MHz
Technical Assistance (800) 343-1391 3
OSCILLOSCOPE OX 9000 SERIES
ACCESSORIES
Accessories automatically recognized
when connected to the oscilloscope
The plug and play accessories included are
automatically recognized when connected to the
oscilloscope. They provide quick and easy
implementation with total user safety. Additionally,
accessories equipped with BNC connectors or
standard banana plugs can also be connected when
using the supplied adapter.
Interchangeable ID Markers can be used on the
accessories plugged into a given channel to identify them
with the trace color displayed on the screen.
Additionally the 10:1 probe accessory is equipped with
3 adjustable buttons to optimize its measurement capabilities.
PROBE FUNCTIONS
voltage measurements
• by probe with different
bandwidths and attenuation
• by BNC or banana jack connection
current measurements
• by AC or AC/DC current clamp
• directly through banana
jack connections
temperature measurements
• using a K thermocouple sensor
• using a PT100 RTD sensor
Identification and Safety Management
Once one of the provided standard accessories has been
plugged in, it is automatically identified and its
characteristics and calibration references are retrieved by
the OX9000 Series Oscilloscope. All accessories are
directly powered by the oscilloscope.
Channel Configuration and Sensor Management
Sensor coefficients scales and units of measure are managed
automatically, as is channel configuration. Control buttons on
the probes can be used to modify the settings of the channels
to which they are connected. They also offer functions
accessible on the oscilloscope's front panel.
Accessories & Replacements
Cat #2124.73 - PROBIX PRHX1 10:1 Probe, 250MHz 600V CAT III
Cat #2124.77 - PROBIX Current Probe, 20mA-20A 1MHz-3dB
Cat #5000.17 - Set of 5 styli pens
4 Technical Assistance (800) 343-1391
COMMUNICATION
For added equipment and operator safety all communication from the
instrument is totally isolated from the measurement process
Choice of communication interfaces―you can choose
the type of communicaton to fit your requirements.
Several communication choices are built into the OX9000
Series oscilloscope.
• Wired Ethernet LAN network with integrated DHCP
server for easy connection to your network
• WiFi® radio link to communicate with a PC, tablet or
smartphone using the dedicated interfaces
• USB for interfacing with the PC; record, recall or
load configurations
• µSD with >8 GB, default storage giving priority over
the 1 GB internal memory
Electrical Troubleshooting
File Management
Any of the signal traces can be displayed instantaneously as
the reference by pressing a single button which will obtain a
comparison an immediate measurements of the deviation of
ongoing measurements.
Backups are available in various formats for direct export into
a standard application such as Windows base spreadsheets
or word processors.
It is easy to take screenshots directly from the front panel and
save them in a .PNG format, print documents on a network
printer and transfer or delete files in the file manager.
Education
t
r
a
c
e
s
(
t
r
c
)
Storage capability
for each mode
s
e
t
u
p
(
c
f
g
)
Type of file
s
c
r
e
e
n
s
h
o
t
(
p
n
g
)
m
e
a
s
(
t
x
t
)
m
a
t
h
(
f
c
t
)
In the laboratory
Oscilloscope mode
Multimeter mode
Logger mode
Harmonics mode
Data Processing
• Use the oscilloscope screen to recall screenshots and
stored traces for direct review on screen
• On your PC, use the ScopeNet application in your web
browser with either the USB or Ethernet connection for
remote control and programming with SCPI commands
Technical Assistance (800) 343-1391 5
4 MODES: Oscilloscope, Multimeter, Analyzer, Recorder
Improved functions and performance levels of the OX9000 Series
• wider bandwidth up to 300 MHz
• new triggering and recording options
• increased storage capacity, and more!
• 12 bit resolution
• 2.5 GS/sec
OSCILLOSCOPE:
Trigger Functions
An oscilloscope with complex trigger functions
records what is necessary, while capturing all the faults
The OX9000 models offer advanced triggers which
complement the main edge trigger options: pulse width,
counting and delay.
• The Delay mode enables you to observe any
event with maximum resolution, even if it occurs
a long time after effective triggering, or on two
different channels.
• The Counting mode enables you to count the
events before triggering, so that you can check the
content of digital frames. For example, the trigger
can be linked to a second “auxiliary” signal which
is different from the “main” signal.
The Math Functions
In oscilloscope mode, the MATH functions (1, 2, 3
and 4) allow you to define a mathematical function
for each of the traces, along with vertical scaling and
labeling of the actual physical unit.
The mathematical editor is capable of displaying 4
calculated traces on which all the automatic or cursor
measurements remain available. This means it is
possible to examine the waveforms, such as the power
(V x I), and perform all the associated measurements.
A large number of operators are available, including +,
-, x and / , as well as more complex operators such as
sine, cosine, exponential, logarithm, square root, etc.
opening the way for specific applications.
Automatic Measurements
Comprehensive automatic measurements are displayed
with cursors for precise analysis. The automatic
measurements window displays all 20 parameters at
the touch of a button for 4 channels. Two horizontal
and vertical cursors can be used to view the section
of the signal where the first automatic measurement
was performed.
A specific measurement area can then be selected
by framing it with manual cursors for more accurate,
reliable results.
Direct comparison of two traces can be performed
by checking the “reference memory deviation” box,
so that these 20 signal parameters are displayed in
terms of deviations.
Real-time Fast Fourier Transform (FFT) for frequency
decomposition of your signals on 4 channels
The FFT is used to calculate, from 2500 points
upwards, the discrete representation of a signal in the
frequency domain from its representation in the time
domain. It is often particularly useful for arriving at an
effective diagnosis during qualitative analysis of
the signals:
• measurement of the individual harmonics or
distortion of a signal
• analysis of a pulse response
• search for the source of noise in the logic circuits
Several weighting windows are available, as well
as 2 representation modes: linear or logarithmic
(scale in dB). The 2 cursors can then be used for
precise measurements of the frequency lines, the
levels and the attenuations, taking advantage of
the 80 dB dynamic range allowed by the 12-bit /
2.5 GS/s conversion.
The autoset button makes it easier to obtain an
optimum spectral representation to which a graphical
zoom can be applied to analyze all the details of
the spectrum.
Technical Assistance (800) 343-13916
VIEW ALL 4 CHANNELS
waveform + XY
SIMULTANEOUSLY
waveform + zoom
waveform + FFT
4 MODES: Oscilloscope, Multimeter, Analyzer, Recorder
The four modes are directly accessed at the press of a button or touch
screen icon providing instant access the mode you need
Harmonic Analysis
Harmonic analysis is performed on all 4 channels up to
the 63rd order to comply with the requirements of the EN
50160 standard (THD on harmonics up to the 50th), with a
fundamental frequency between 40 and 450 Hz.
It is possible to preselect the frequency of the fundamental
for the standards (50 Hz, 60 Hz and 400 Hz).
This function helps to improve analytical performance and,
above all, measurement when the level of a harmonic order
is greater than the fundamental.
It is possible to view the harmonic analyses of two or four
channels simultaneously: RMS level, harmonic distortion,
harmonic frequency, phase of the harmonic in relation to
the fundamental.
Harmonics
4 Simultaneous Channels
Multimeter
By simply selecting the dedicated icons, you can gain access
to the multimeter mode without changing the measurement
input channels. The OX9000 models offer an 8,000-count
TRMS digital multimeter with two or four channels which can
perform the following measurements:
• amplitude (DC or AC voltage and current, power,
temperature, etc.)
• resistance, continuity, capacitance
• component diode tests
Temperature is measured using the Pt 100 and Pt 1000
sensors or K thermocouples via the dedicated PROBIX
sensors. The power measurements are proposed as follows
with choice of the configuration:
• single-phase power
• three-phase power on balanced network without neutral
• three-phase power on balanced network with neutral
• 3-wire three-phase power (2-wattmeters method)
Measurement between H and V cursors:
T1, T2, Dt, 1/Dt, V1, V2, dV, Ph
Recorder/logger
This is the mode for recording the trends in Multimeter mode. A genuine fast digital logger is provided inside the
instrument to monitor the variations of physical or mechanical phenomena over time. It offers acquisition intervals
as short as 40µs between 2 measurements and recording can cover any period from 2 seconds to one month.
Technical Assistance (800) 343-1391 7
TECHNICAL SPECIFICATIONS
HUMAN-MACHINE INTERFACE
Type of display
Different display mode
Display of curves on screen
Screen commands
Choice of language
OSCILLOSCOPE MODE
Vertical deflection
Bandwidth
Number of channels
Input impedance
Maximum input voltage
Vertical sensitivity
Vertical zoom
Probe factor (non-Probix)
Horizontal deflection
Sweep speed
Horizontal zoom
Triggering
Mode
Type
Coupling
Sensitivity
Digital storage
Maximum sampling rate
Vertical resolution
Memory depth
User storage
File management
GLITCH mode
Display modes
Other functions
AUTOSET
FFT analyzer & MATH functions
Cursors
Automatic measurements
MULTIMETER MODE
General specifications
AC, DC and AC + DC voltages
Resistance
Other measurements
Single and three-phase power
HARMONIC ANALYSER MODE
Multi-channel analysis
Simultaneous measurements
LOGGER MODE
Acquisition
GENERAL SPECIFICATIONS
Configuration memories
Printing
PC communication – software link
Software
Mains power supply
Safety / EMC
Mechanical specifications
OX 9062OX 9102OX 9104OX 9304
7" WVGA color TFT LCD touch screen, 800x480 – LED backlighting (adjustable standby mode)
2,500 real acquisition points on screen - Vectors with interpolation
4 curves + 4 references – Split Screen & Full Screen modes
Touch screen – ANDROID-type icons and graphical commands – customizable channel colors
15 complete languages, menus & online help
60 MHz
2 isolated channels
100 MHz100 MHz
4 isolated channels
300 MHz
15 MHz, 1.5 MHz or 5 kHz bandwidth limiter
1 MΩ ± 0.5% , approx. 12 pF
600 V / CAT III (1,000V per Probix) – from 50 to 400 Hz – Probix safety connectors
16 ranges from 2.5 mV to 200 V/div and up to 156 µV/div in vertical zoom mode (12-bit converter) – Accuracy ± 2%
"One Click Winzoom" mode (12-bit converter and direct graphical zoom on screen) – x 16 max.
1 / 10 / 100 / 1,000 or any scaling – definition of measurement unit
35 ranges from 1 ns/div to 200 s/div., accuracy ± [50 ppm + 500 ps] – Roll mode from 100 ms to 200 s/div
"One Click Winzoom" system (direct graphical zoom on screen) x 1 to x 5 or x 100 – storage 100 kpts/channel
On all the channels: automatic, triggered, one-shot, auto level 50%
Edge, pulse width (16 ns-20 s), delay (48 ns to 20 s), counting (3 to 16,384 events) Continuous adjustment of Trigger position
AC, DC GND, HFR, LFR, noise – Level and Hold-Off adjustable from 64 ns to 15 s
≤ 1.2 division p-p up to 300 MHz
2.5 GS/s in one-shot mode on each channel (100 GS/s max. in ETS mode)
12 bits (vertical resolution 0.025 %)
100 kpts per channel and file viewer in the manager
Internal = 1 GB to store the files: trace, text, configuration, math functions, System memory: .pdf print files, .png image files
+ high-capacity removable µSD-Card: SD 2 GB, SDHC 4-32 GB and SDXC > 32 GB
Duration ≤ 2 ns – 500,000 Min/Max pairs
Envelope, vector, accumulation-, averaging (factors 2 to 64) – XY (vector) and Y(f)=FFT
Complete in under 5 s, with recognition of the channels – Frequency > 30 Hz
2,500-point FFT (Lin or Log) with measurement cursors – Functions + , - , x , / and mathematical function editor
2 or 3 cursors: simultaneous V and T with AUTO measurement: T1, T2, Dt, 1/Dt, dBV, Ph
Simultaneously with waveform, 20 automatic measurements per channel and on the 4 channels simultaneously with scroll
2 or 4 channels – 8,000 cts min/max/frequency/relative – TRMS – Time/date-stamped graphical recording in logger mode
600 mV to 600 VRMS, 800 mV to 800 VDC – VDC accuracy +/- (0.5 % + 25 D) – 200 kHz bandwidth
80 Ω to 32 MΩ – accuracy 0.5%R+ 25D – Quick continuity test < 10 ms
Temperature (HX0035 = KTC, HX0036 = Pt100) / Capacitance 5nF to 5mF / Frequency 200 kHz / Diode test 3.3 V
Active, Reactive and Apparent power values plus Power Factor simultaneously with the U & I measurements
2 or 4 (depending on model), 63 orders, fundamental frequency 40 to 450 Hz in auto or manual mode
Total Vrms, THD and selected order (% fundamental, phase, frequency, Vrms)
Duration: 20,000 s – Interval: 0.2 s – Files: 100,000 measurements
Not limited according to device - variable file sizes
Network printing via Ethernet/Wifi in .png format
Ethernet (100 baseT), WiFi-USB (device, 12 Mbs) – "ScopeNet" application software for PC
PC: Ethernet and USB, ScopeNet (remote control, data recovery, cursors and automatic measurements)
Android tablet – ScopeAdmin Fleet Administration utility
Li-Ion rechargeable battery (6,900mAH-40 Wh) – Battery life of up to 8 hrs – Adjustable standby mode
Adapter / 2-hour fast charger, universal 98-264 V / 50/60 Hz)
Safety as per IEC 61010-2-30, 2010 – 600V CAT III / 1000V CAT II – EMC as per EN61326-1, 2010
292.5 x 210.6 x 66.2 mm – 2.1 kg with batteries – IP54 protection
For Your Electrical/Power Test & Measurement Instruments
Call the AEMC
®
Instruments Technical Assistance Hotline for immediate consultation with an applications engineer: (800) 343-1391 (Ext. 351)
Chauvin Arnoux
®
, Inc. d.b.a AEMC
®
Instruments • 15 Faraday Dr. • Dover, NH 03820 USA • (800) 343-1391 • (508) 698-2115 • Fax (508) 698-2118
E-mail:**************| Export Department: +1 (603) 749-6434 x520 • Fax +1 (603) 740-7550 •E-mail:***************
-OX9000Series_1021 • Printed in the USA
© 2021 Chauvin Arnoux
®
, Inc. d.b.a. AEMC® Instruments
2024年9月29日发(作者:释芳润)
Oscilloscope
OX 9000 SERIES
isolated channels
4-in-1 Instrument
Oscilloscope
Multimeter
Analyzer
Logger
with the recorded files directly
viewable on screen
Safety
• All channels isolated from one another
and from the earth, 600V CAT III
Ergonomic
• Modern, high tech design which is
simple, compact and practical
Optimization
• of all tools; communication, storage
and operation
Our products are backed by over 125 years of experience in test and measurement
equipment, and encompass the latest international standards for quality and safety.
(800) 343-1391
ERGONOMICS
Designed to simplify use with one button access to most functions
In a housing tailor-made to be as compact as possible,
the mechanical design makes it possible to integrate
the hardware components in a small size with the
keypad benefits from new technology developed in
the automotive industry.
IP
54
Original
CHANNEL AND PARAMETER IDENTIFICATION
Each channel and related parameters are identified with identical
color against a black background for simpler, quicker viewing.
EASY ACCESS VIA TOUCH SCREEN
Intuitive icons are provided to facilitate their use, even with gloves on.
ADJUSTABLE STRAP
This helps to optimize operation of the oscilloscope in your hand
or on your shoulder when working in the field.
A stand is also available to vary the orientation of the oscilloscope
when it is placed on a bench. The oscilloscope can be safely left
unattended using the Kensington locking system.
NEW KEYPAD DESIGN FOR OPTIMUM USER COMFORT
Configuration and measurement displays are simple to access from
the front panel in one of these 5 specific areas: Utilities (brightness,
full screen, screenshot), Measurements, Vertical, Horizontal, Trigger.
LINE POWER OR LI-ION BATTERY
Port on left side.
Scope in carrying case with shoulder strap, set of two 5 ft color-coded leads, alligator clips
and test probes, 10 ft USB cable, µSD memory card, 1-PROBIX Banana Plug Adapter, 1 styli
pen, LI-ION 5.8 Ah battery pack, PA40W-2 power adapter with 110V power cord. Additional
accessories may be model dependent.
2 Technical Assistance (800) 343-1391
APPLICATIONS
Ideal for electronic and industrial maintenance
Electronic maintenance
The OX 9304 model is ideal for electronics with its
300 MHz bandwidth, 4 x 600V CAT III isolated channels,
advanced trigger functions, integrated FFT function,
complex mathematical calculations on the curves, automatic
measurements on 4 channels and the built-in WEB server.
IP54
Housing protected against dust and water spray.
7" WVGA WIDE COLOR TFT TOUCH SCREEN
Makes it easy to view and read the measurements clearly.
It also provides a screen resolution of 800 x 480 dpi with manual
or automatic brightness.
TOUCH-SCREEN STYLUS STORAGE
Among the essential tools available, the sylus is equipped with a
hook for the addition of a cord to make it captive, as required. One
end is slightly flattened to prevent rolling when placed on a table
or bench.
AUTOSET BUTTON
Quickly and effortlessly adjusts the horizontal and vertical;
sensitivity and scales to provide the best resolution.
Industrial maintenance
The OX 9304’s large 7-inch screen, 300 MHz bandwidth,
4 x 600V CAT III isolated channels and Harmonic
Analyzer and Multimeter modes make it ideal for
industrial maintenance applications.
DIRECT SETTING AND SET-UP BUTTONS
COMMUNICATION INTERFACES
These are isolated from one another and from the measurement
channels. A dedicated compartment on the right side protected
by a flexible cover contains all the different communication
interface ports:
•
USB host for communication with a PC
•
wired RJ45 or WiFi for communication with a PC or
•
µSD card for data storage with quick transfer and for
upgrading of the instrument's firmware
printing via a network printer
DIRECT ACCESS ZOOM BUTTON
Channels are isolated.
CATALOG NO. DESCRIPTION
2150.31 ....................................................................................................................................Hand-Held Oscilloscope Model OX 9062 IV 60MHz
2150.32 ..................................................................................................................................Hand-Held Oscilloscope Model OX 9102 IV 100MHz
2150.33 ..................................................................................................................................Hand-Held Oscilloscope Model OX 9104 IV 100MHz
2150.34 ..................................................................................................................................Hand-Held Oscilloscope Model OX 9304 IV 300MHz
Technical Assistance (800) 343-1391 3
OSCILLOSCOPE OX 9000 SERIES
ACCESSORIES
Accessories automatically recognized
when connected to the oscilloscope
The plug and play accessories included are
automatically recognized when connected to the
oscilloscope. They provide quick and easy
implementation with total user safety. Additionally,
accessories equipped with BNC connectors or
standard banana plugs can also be connected when
using the supplied adapter.
Interchangeable ID Markers can be used on the
accessories plugged into a given channel to identify them
with the trace color displayed on the screen.
Additionally the 10:1 probe accessory is equipped with
3 adjustable buttons to optimize its measurement capabilities.
PROBE FUNCTIONS
voltage measurements
• by probe with different
bandwidths and attenuation
• by BNC or banana jack connection
current measurements
• by AC or AC/DC current clamp
• directly through banana
jack connections
temperature measurements
• using a K thermocouple sensor
• using a PT100 RTD sensor
Identification and Safety Management
Once one of the provided standard accessories has been
plugged in, it is automatically identified and its
characteristics and calibration references are retrieved by
the OX9000 Series Oscilloscope. All accessories are
directly powered by the oscilloscope.
Channel Configuration and Sensor Management
Sensor coefficients scales and units of measure are managed
automatically, as is channel configuration. Control buttons on
the probes can be used to modify the settings of the channels
to which they are connected. They also offer functions
accessible on the oscilloscope's front panel.
Accessories & Replacements
Cat #2124.73 - PROBIX PRHX1 10:1 Probe, 250MHz 600V CAT III
Cat #2124.77 - PROBIX Current Probe, 20mA-20A 1MHz-3dB
Cat #5000.17 - Set of 5 styli pens
4 Technical Assistance (800) 343-1391
COMMUNICATION
For added equipment and operator safety all communication from the
instrument is totally isolated from the measurement process
Choice of communication interfaces―you can choose
the type of communicaton to fit your requirements.
Several communication choices are built into the OX9000
Series oscilloscope.
• Wired Ethernet LAN network with integrated DHCP
server for easy connection to your network
• WiFi® radio link to communicate with a PC, tablet or
smartphone using the dedicated interfaces
• USB for interfacing with the PC; record, recall or
load configurations
• µSD with >8 GB, default storage giving priority over
the 1 GB internal memory
Electrical Troubleshooting
File Management
Any of the signal traces can be displayed instantaneously as
the reference by pressing a single button which will obtain a
comparison an immediate measurements of the deviation of
ongoing measurements.
Backups are available in various formats for direct export into
a standard application such as Windows base spreadsheets
or word processors.
It is easy to take screenshots directly from the front panel and
save them in a .PNG format, print documents on a network
printer and transfer or delete files in the file manager.
Education
t
r
a
c
e
s
(
t
r
c
)
Storage capability
for each mode
s
e
t
u
p
(
c
f
g
)
Type of file
s
c
r
e
e
n
s
h
o
t
(
p
n
g
)
m
e
a
s
(
t
x
t
)
m
a
t
h
(
f
c
t
)
In the laboratory
Oscilloscope mode
Multimeter mode
Logger mode
Harmonics mode
Data Processing
• Use the oscilloscope screen to recall screenshots and
stored traces for direct review on screen
• On your PC, use the ScopeNet application in your web
browser with either the USB or Ethernet connection for
remote control and programming with SCPI commands
Technical Assistance (800) 343-1391 5
4 MODES: Oscilloscope, Multimeter, Analyzer, Recorder
Improved functions and performance levels of the OX9000 Series
• wider bandwidth up to 300 MHz
• new triggering and recording options
• increased storage capacity, and more!
• 12 bit resolution
• 2.5 GS/sec
OSCILLOSCOPE:
Trigger Functions
An oscilloscope with complex trigger functions
records what is necessary, while capturing all the faults
The OX9000 models offer advanced triggers which
complement the main edge trigger options: pulse width,
counting and delay.
• The Delay mode enables you to observe any
event with maximum resolution, even if it occurs
a long time after effective triggering, or on two
different channels.
• The Counting mode enables you to count the
events before triggering, so that you can check the
content of digital frames. For example, the trigger
can be linked to a second “auxiliary” signal which
is different from the “main” signal.
The Math Functions
In oscilloscope mode, the MATH functions (1, 2, 3
and 4) allow you to define a mathematical function
for each of the traces, along with vertical scaling and
labeling of the actual physical unit.
The mathematical editor is capable of displaying 4
calculated traces on which all the automatic or cursor
measurements remain available. This means it is
possible to examine the waveforms, such as the power
(V x I), and perform all the associated measurements.
A large number of operators are available, including +,
-, x and / , as well as more complex operators such as
sine, cosine, exponential, logarithm, square root, etc.
opening the way for specific applications.
Automatic Measurements
Comprehensive automatic measurements are displayed
with cursors for precise analysis. The automatic
measurements window displays all 20 parameters at
the touch of a button for 4 channels. Two horizontal
and vertical cursors can be used to view the section
of the signal where the first automatic measurement
was performed.
A specific measurement area can then be selected
by framing it with manual cursors for more accurate,
reliable results.
Direct comparison of two traces can be performed
by checking the “reference memory deviation” box,
so that these 20 signal parameters are displayed in
terms of deviations.
Real-time Fast Fourier Transform (FFT) for frequency
decomposition of your signals on 4 channels
The FFT is used to calculate, from 2500 points
upwards, the discrete representation of a signal in the
frequency domain from its representation in the time
domain. It is often particularly useful for arriving at an
effective diagnosis during qualitative analysis of
the signals:
• measurement of the individual harmonics or
distortion of a signal
• analysis of a pulse response
• search for the source of noise in the logic circuits
Several weighting windows are available, as well
as 2 representation modes: linear or logarithmic
(scale in dB). The 2 cursors can then be used for
precise measurements of the frequency lines, the
levels and the attenuations, taking advantage of
the 80 dB dynamic range allowed by the 12-bit /
2.5 GS/s conversion.
The autoset button makes it easier to obtain an
optimum spectral representation to which a graphical
zoom can be applied to analyze all the details of
the spectrum.
Technical Assistance (800) 343-13916
VIEW ALL 4 CHANNELS
waveform + XY
SIMULTANEOUSLY
waveform + zoom
waveform + FFT
4 MODES: Oscilloscope, Multimeter, Analyzer, Recorder
The four modes are directly accessed at the press of a button or touch
screen icon providing instant access the mode you need
Harmonic Analysis
Harmonic analysis is performed on all 4 channels up to
the 63rd order to comply with the requirements of the EN
50160 standard (THD on harmonics up to the 50th), with a
fundamental frequency between 40 and 450 Hz.
It is possible to preselect the frequency of the fundamental
for the standards (50 Hz, 60 Hz and 400 Hz).
This function helps to improve analytical performance and,
above all, measurement when the level of a harmonic order
is greater than the fundamental.
It is possible to view the harmonic analyses of two or four
channels simultaneously: RMS level, harmonic distortion,
harmonic frequency, phase of the harmonic in relation to
the fundamental.
Harmonics
4 Simultaneous Channels
Multimeter
By simply selecting the dedicated icons, you can gain access
to the multimeter mode without changing the measurement
input channels. The OX9000 models offer an 8,000-count
TRMS digital multimeter with two or four channels which can
perform the following measurements:
• amplitude (DC or AC voltage and current, power,
temperature, etc.)
• resistance, continuity, capacitance
• component diode tests
Temperature is measured using the Pt 100 and Pt 1000
sensors or K thermocouples via the dedicated PROBIX
sensors. The power measurements are proposed as follows
with choice of the configuration:
• single-phase power
• three-phase power on balanced network without neutral
• three-phase power on balanced network with neutral
• 3-wire three-phase power (2-wattmeters method)
Measurement between H and V cursors:
T1, T2, Dt, 1/Dt, V1, V2, dV, Ph
Recorder/logger
This is the mode for recording the trends in Multimeter mode. A genuine fast digital logger is provided inside the
instrument to monitor the variations of physical or mechanical phenomena over time. It offers acquisition intervals
as short as 40µs between 2 measurements and recording can cover any period from 2 seconds to one month.
Technical Assistance (800) 343-1391 7
TECHNICAL SPECIFICATIONS
HUMAN-MACHINE INTERFACE
Type of display
Different display mode
Display of curves on screen
Screen commands
Choice of language
OSCILLOSCOPE MODE
Vertical deflection
Bandwidth
Number of channels
Input impedance
Maximum input voltage
Vertical sensitivity
Vertical zoom
Probe factor (non-Probix)
Horizontal deflection
Sweep speed
Horizontal zoom
Triggering
Mode
Type
Coupling
Sensitivity
Digital storage
Maximum sampling rate
Vertical resolution
Memory depth
User storage
File management
GLITCH mode
Display modes
Other functions
AUTOSET
FFT analyzer & MATH functions
Cursors
Automatic measurements
MULTIMETER MODE
General specifications
AC, DC and AC + DC voltages
Resistance
Other measurements
Single and three-phase power
HARMONIC ANALYSER MODE
Multi-channel analysis
Simultaneous measurements
LOGGER MODE
Acquisition
GENERAL SPECIFICATIONS
Configuration memories
Printing
PC communication – software link
Software
Mains power supply
Safety / EMC
Mechanical specifications
OX 9062OX 9102OX 9104OX 9304
7" WVGA color TFT LCD touch screen, 800x480 – LED backlighting (adjustable standby mode)
2,500 real acquisition points on screen - Vectors with interpolation
4 curves + 4 references – Split Screen & Full Screen modes
Touch screen – ANDROID-type icons and graphical commands – customizable channel colors
15 complete languages, menus & online help
60 MHz
2 isolated channels
100 MHz100 MHz
4 isolated channels
300 MHz
15 MHz, 1.5 MHz or 5 kHz bandwidth limiter
1 MΩ ± 0.5% , approx. 12 pF
600 V / CAT III (1,000V per Probix) – from 50 to 400 Hz – Probix safety connectors
16 ranges from 2.5 mV to 200 V/div and up to 156 µV/div in vertical zoom mode (12-bit converter) – Accuracy ± 2%
"One Click Winzoom" mode (12-bit converter and direct graphical zoom on screen) – x 16 max.
1 / 10 / 100 / 1,000 or any scaling – definition of measurement unit
35 ranges from 1 ns/div to 200 s/div., accuracy ± [50 ppm + 500 ps] – Roll mode from 100 ms to 200 s/div
"One Click Winzoom" system (direct graphical zoom on screen) x 1 to x 5 or x 100 – storage 100 kpts/channel
On all the channels: automatic, triggered, one-shot, auto level 50%
Edge, pulse width (16 ns-20 s), delay (48 ns to 20 s), counting (3 to 16,384 events) Continuous adjustment of Trigger position
AC, DC GND, HFR, LFR, noise – Level and Hold-Off adjustable from 64 ns to 15 s
≤ 1.2 division p-p up to 300 MHz
2.5 GS/s in one-shot mode on each channel (100 GS/s max. in ETS mode)
12 bits (vertical resolution 0.025 %)
100 kpts per channel and file viewer in the manager
Internal = 1 GB to store the files: trace, text, configuration, math functions, System memory: .pdf print files, .png image files
+ high-capacity removable µSD-Card: SD 2 GB, SDHC 4-32 GB and SDXC > 32 GB
Duration ≤ 2 ns – 500,000 Min/Max pairs
Envelope, vector, accumulation-, averaging (factors 2 to 64) – XY (vector) and Y(f)=FFT
Complete in under 5 s, with recognition of the channels – Frequency > 30 Hz
2,500-point FFT (Lin or Log) with measurement cursors – Functions + , - , x , / and mathematical function editor
2 or 3 cursors: simultaneous V and T with AUTO measurement: T1, T2, Dt, 1/Dt, dBV, Ph
Simultaneously with waveform, 20 automatic measurements per channel and on the 4 channels simultaneously with scroll
2 or 4 channels – 8,000 cts min/max/frequency/relative – TRMS – Time/date-stamped graphical recording in logger mode
600 mV to 600 VRMS, 800 mV to 800 VDC – VDC accuracy +/- (0.5 % + 25 D) – 200 kHz bandwidth
80 Ω to 32 MΩ – accuracy 0.5%R+ 25D – Quick continuity test < 10 ms
Temperature (HX0035 = KTC, HX0036 = Pt100) / Capacitance 5nF to 5mF / Frequency 200 kHz / Diode test 3.3 V
Active, Reactive and Apparent power values plus Power Factor simultaneously with the U & I measurements
2 or 4 (depending on model), 63 orders, fundamental frequency 40 to 450 Hz in auto or manual mode
Total Vrms, THD and selected order (% fundamental, phase, frequency, Vrms)
Duration: 20,000 s – Interval: 0.2 s – Files: 100,000 measurements
Not limited according to device - variable file sizes
Network printing via Ethernet/Wifi in .png format
Ethernet (100 baseT), WiFi-USB (device, 12 Mbs) – "ScopeNet" application software for PC
PC: Ethernet and USB, ScopeNet (remote control, data recovery, cursors and automatic measurements)
Android tablet – ScopeAdmin Fleet Administration utility
Li-Ion rechargeable battery (6,900mAH-40 Wh) – Battery life of up to 8 hrs – Adjustable standby mode
Adapter / 2-hour fast charger, universal 98-264 V / 50/60 Hz)
Safety as per IEC 61010-2-30, 2010 – 600V CAT III / 1000V CAT II – EMC as per EN61326-1, 2010
292.5 x 210.6 x 66.2 mm – 2.1 kg with batteries – IP54 protection
For Your Electrical/Power Test & Measurement Instruments
Call the AEMC
®
Instruments Technical Assistance Hotline for immediate consultation with an applications engineer: (800) 343-1391 (Ext. 351)
Chauvin Arnoux
®
, Inc. d.b.a AEMC
®
Instruments • 15 Faraday Dr. • Dover, NH 03820 USA • (800) 343-1391 • (508) 698-2115 • Fax (508) 698-2118
E-mail:**************| Export Department: +1 (603) 749-6434 x520 • Fax +1 (603) 740-7550 •E-mail:***************
-OX9000Series_1021 • Printed in the USA
© 2021 Chauvin Arnoux
®
, Inc. d.b.a. AEMC® Instruments