最新消息: USBMI致力于为网友们分享Windows、安卓、IOS等主流手机系统相关的资讯以及评测、同时提供相关教程、应用、软件下载等服务。

奥斯卡作用域OX 9000系列4合1仪器作用域多功能仪表分析仪记录器安全说

IT圈 admin 22浏览 0评论

2024年9月29日发(作者:释芳润)

Oscilloscope

OX 9000 SERIES

isolated channels

4-in-1 Instrument

Oscilloscope

Multimeter

Analyzer

Logger

with the recorded files directly

viewable on screen

Safety

• All channels isolated from one another

and from the earth, 600V CAT III

Ergonomic

• Modern, high tech design which is

simple, compact and practical

Optimization

• of all tools; communication, storage

and operation

Our products are backed by over 125 years of experience in test and measurement

equipment, and encompass the latest international standards for quality and safety.

(800) 343-1391

ERGONOMICS

Designed to simplify use with one button access to most functions

In a housing tailor-made to be as compact as possible,

the mechanical design makes it possible to integrate

the hardware components in a small size with the

keypad benefits from new technology developed in

the automotive industry.

IP

54

Original

CHANNEL AND PARAMETER IDENTIFICATION

Each channel and related parameters are identified with identical

color against a black background for simpler, quicker viewing.

EASY ACCESS VIA TOUCH SCREEN

Intuitive icons are provided to facilitate their use, even with gloves on.

ADJUSTABLE STRAP

This helps to optimize operation of the oscilloscope in your hand

or on your shoulder when working in the field.

A stand is also available to vary the orientation of the oscilloscope

when it is placed on a bench. The oscilloscope can be safely left

unattended using the Kensington locking system.

NEW KEYPAD DESIGN FOR OPTIMUM USER COMFORT

Configuration and measurement displays are simple to access from

the front panel in one of these 5 specific areas: Utilities (brightness,

full screen, screenshot), Measurements, Vertical, Horizontal, Trigger.

LINE POWER OR LI-ION BATTERY

Port on left side.

Scope in carrying case with shoulder strap, set of two 5 ft color-coded leads, alligator clips

and test probes, 10 ft USB cable, µSD memory card, 1-PROBIX Banana Plug Adapter, 1 styli

pen, LI-ION 5.8 Ah battery pack, PA40W-2 power adapter with 110V power cord. Additional

accessories may be model dependent.

2 Technical Assistance (800) 343-1391

APPLICATIONS

Ideal for electronic and industrial maintenance

Electronic maintenance

The OX 9304 model is ideal for electronics with its

300 MHz bandwidth, 4 x 600V CAT III isolated channels,

advanced trigger functions, integrated FFT function,

complex mathematical calculations on the curves, automatic

measurements on 4 channels and the built-in WEB server.

IP54

Housing protected against dust and water spray.

7" WVGA WIDE COLOR TFT TOUCH SCREEN

Makes it easy to view and read the measurements clearly.

It also provides a screen resolution of 800 x 480 dpi with manual

or automatic brightness.

TOUCH-SCREEN STYLUS STORAGE

Among the essential tools available, the sylus is equipped with a

hook for the addition of a cord to make it captive, as required. One

end is slightly flattened to prevent rolling when placed on a table

or bench.

AUTOSET BUTTON

Quickly and effortlessly adjusts the horizontal and vertical;

sensitivity and scales to provide the best resolution.

Industrial maintenance

The OX 9304’s large 7-inch screen, 300 MHz bandwidth,

4 x 600V CAT III isolated channels and Harmonic

Analyzer and Multimeter modes make it ideal for

industrial maintenance applications.

DIRECT SETTING AND SET-UP BUTTONS

COMMUNICATION INTERFACES

These are isolated from one another and from the measurement

channels. A dedicated compartment on the right side protected

by a flexible cover contains all the different communication

interface ports:

USB host for communication with a PC

wired RJ45 or WiFi for communication with a PC or

µSD card for data storage with quick transfer and for

upgrading of the instrument's firmware

printing via a network printer

DIRECT ACCESS ZOOM BUTTON

Channels are isolated.

CATALOG NO. DESCRIPTION

2150.31 ....................................................................................................................................Hand-Held Oscilloscope Model OX 9062 IV 60MHz

2150.32 ..................................................................................................................................Hand-Held Oscilloscope Model OX 9102 IV 100MHz

2150.33 ..................................................................................................................................Hand-Held Oscilloscope Model OX 9104 IV 100MHz

2150.34 ..................................................................................................................................Hand-Held Oscilloscope Model OX 9304 IV 300MHz

Technical Assistance (800) 343-1391 3

OSCILLOSCOPE OX 9000 SERIES

ACCESSORIES

Accessories automatically recognized

when connected to the oscilloscope

The plug and play accessories included are

automatically recognized when connected to the

oscilloscope. They provide quick and easy

implementation with total user safety. Additionally,

accessories equipped with BNC connectors or

standard banana plugs can also be connected when

using the supplied adapter.

Interchangeable ID Markers can be used on the

accessories plugged into a given channel to identify them

with the trace color displayed on the screen.

Additionally the 10:1 probe accessory is equipped with

3 adjustable buttons to optimize its measurement capabilities.

PROBE FUNCTIONS

voltage measurements

• by probe with different

bandwidths and attenuation

• by BNC or banana jack connection

current measurements

• by AC or AC/DC current clamp

• directly through banana

jack connections

temperature measurements

• using a K thermocouple sensor

• using a PT100 RTD sensor

Identification and Safety Management

Once one of the provided standard accessories has been

plugged in, it is automatically identified and its

characteristics and calibration references are retrieved by

the OX9000 Series Oscilloscope. All accessories are

directly powered by the oscilloscope.

Channel Configuration and Sensor Management

Sensor coefficients scales and units of measure are managed

automatically, as is channel configuration. Control buttons on

the probes can be used to modify the settings of the channels

to which they are connected. They also offer functions

accessible on the oscilloscope's front panel.

Accessories & Replacements

Cat #2124.73 - PROBIX PRHX1 10:1 Probe, 250MHz 600V CAT III

Cat #2124.77 - PROBIX Current Probe, 20mA-20A 1MHz-3dB

Cat #5000.17 - Set of 5 styli pens

4 Technical Assistance (800) 343-1391

COMMUNICATION

For added equipment and operator safety all communication from the

instrument is totally isolated from the measurement process

Choice of communication interfaces―you can choose

the type of communicaton to fit your requirements.

Several communication choices are built into the OX9000

Series oscilloscope.

• Wired Ethernet LAN network with integrated DHCP

server for easy connection to your network

• WiFi® radio link to communicate with a PC, tablet or

smartphone using the dedicated interfaces

• USB for interfacing with the PC; record, recall or

load configurations

• µSD with >8 GB, default storage giving priority over

the 1 GB internal memory

Electrical Troubleshooting

File Management

Any of the signal traces can be displayed instantaneously as

the reference by pressing a single button which will obtain a

comparison an immediate measurements of the deviation of

ongoing measurements.

Backups are available in various formats for direct export into

a standard application such as Windows base spreadsheets

or word processors.

It is easy to take screenshots directly from the front panel and

save them in a .PNG format, print documents on a network

printer and transfer or delete files in the file manager.

Education

t

r

a

c

e

s

(

t

r

c

)

Storage capability

for each mode

s

e

t

u

p

(

c

f

g

)

Type of file

s

c

r

e

e

n

s

h

o

t

(

p

n

g

)

m

e

a

s

(

t

x

t

)

m

a

t

h

(

f

c

t

)

In the laboratory

Oscilloscope mode

Multimeter mode

Logger mode

Harmonics mode





Data Processing

• Use the oscilloscope screen to recall screenshots and

stored traces for direct review on screen

• On your PC, use the ScopeNet application in your web

browser with either the USB or Ethernet connection for

remote control and programming with SCPI commands

Technical Assistance (800) 343-1391 5

4 MODES: Oscilloscope, Multimeter, Analyzer, Recorder

Improved functions and performance levels of the OX9000 Series

• wider bandwidth up to 300 MHz

• new triggering and recording options

• increased storage capacity, and more!

• 12 bit resolution

• 2.5 GS/sec

OSCILLOSCOPE:

Trigger Functions

An oscilloscope with complex trigger functions

records what is necessary, while capturing all the faults

The OX9000 models offer advanced triggers which

complement the main edge trigger options: pulse width,

counting and delay.

• The Delay mode enables you to observe any

event with maximum resolution, even if it occurs

a long time after effective triggering, or on two

different channels.

• The Counting mode enables you to count the

events before triggering, so that you can check the

content of digital frames. For example, the trigger

can be linked to a second “auxiliary” signal which

is different from the “main” signal.

The Math Functions

In oscilloscope mode, the MATH functions (1, 2, 3

and 4) allow you to define a mathematical function

for each of the traces, along with vertical scaling and

labeling of the actual physical unit.

The mathematical editor is capable of displaying 4

calculated traces on which all the automatic or cursor

measurements remain available. This means it is

possible to examine the waveforms, such as the power

(V x I), and perform all the associated measurements.

A large number of operators are available, including +,

-, x and / , as well as more complex operators such as

sine, cosine, exponential, logarithm, square root, etc.

opening the way for specific applications.

Automatic Measurements

Comprehensive automatic measurements are displayed

with cursors for precise analysis. The automatic

measurements window displays all 20 parameters at

the touch of a button for 4 channels. Two horizontal

and vertical cursors can be used to view the section

of the signal where the first automatic measurement

was performed.

A specific measurement area can then be selected

by framing it with manual cursors for more accurate,

reliable results.

Direct comparison of two traces can be performed

by checking the “reference memory deviation” box,

so that these 20 signal parameters are displayed in

terms of deviations.

Real-time Fast Fourier Transform (FFT) for frequency

decomposition of your signals on 4 channels

The FFT is used to calculate, from 2500 points

upwards, the discrete representation of a signal in the

frequency domain from its representation in the time

domain. It is often particularly useful for arriving at an

effective diagnosis during qualitative analysis of

the signals:

• measurement of the individual harmonics or

distortion of a signal

• analysis of a pulse response

• search for the source of noise in the logic circuits

Several weighting windows are available, as well

as 2 representation modes: linear or logarithmic

(scale in dB). The 2 cursors can then be used for

precise measurements of the frequency lines, the

levels and the attenuations, taking advantage of

the 80 dB dynamic range allowed by the 12-bit /

2.5 GS/s conversion.

The autoset button makes it easier to obtain an

optimum spectral representation to which a graphical

zoom can be applied to analyze all the details of

the spectrum.

Technical Assistance (800) 343-13916

VIEW ALL 4 CHANNELS

waveform + XY

SIMULTANEOUSLY

waveform + zoom

waveform + FFT

4 MODES: Oscilloscope, Multimeter, Analyzer, Recorder

The four modes are directly accessed at the press of a button or touch

screen icon providing instant access the mode you need

Harmonic Analysis

Harmonic analysis is performed on all 4 channels up to

the 63rd order to comply with the requirements of the EN

50160 standard (THD on harmonics up to the 50th), with a

fundamental frequency between 40 and 450 Hz.

It is possible to preselect the frequency of the fundamental

for the standards (50 Hz, 60 Hz and 400 Hz).

This function helps to improve analytical performance and,

above all, measurement when the level of a harmonic order

is greater than the fundamental.

It is possible to view the harmonic analyses of two or four

channels simultaneously: RMS level, harmonic distortion,

harmonic frequency, phase of the harmonic in relation to

the fundamental.

Harmonics

4 Simultaneous Channels

Multimeter

By simply selecting the dedicated icons, you can gain access

to the multimeter mode without changing the measurement

input channels. The OX9000 models offer an 8,000-count

TRMS digital multimeter with two or four channels which can

perform the following measurements:

• amplitude (DC or AC voltage and current, power,

temperature, etc.)

• resistance, continuity, capacitance

• component diode tests

Temperature is measured using the Pt 100 and Pt 1000

sensors or K thermocouples via the dedicated PROBIX

sensors. The power measurements are proposed as follows

with choice of the configuration:

• single-phase power

• three-phase power on balanced network without neutral

• three-phase power on balanced network with neutral

• 3-wire three-phase power (2-wattmeters method)

Measurement between H and V cursors:

T1, T2, Dt, 1/Dt, V1, V2, dV, Ph

Recorder/logger

This is the mode for recording the trends in Multimeter mode. A genuine fast digital logger is provided inside the

instrument to monitor the variations of physical or mechanical phenomena over time. It offers acquisition intervals

as short as 40µs between 2 measurements and recording can cover any period from 2 seconds to one month.

Technical Assistance (800) 343-1391 7

TECHNICAL SPECIFICATIONS

HUMAN-MACHINE INTERFACE

Type of display

Different display mode

Display of curves on screen

Screen commands

Choice of language

OSCILLOSCOPE MODE

Vertical deflection

Bandwidth

Number of channels

Input impedance

Maximum input voltage

Vertical sensitivity

Vertical zoom

Probe factor (non-Probix)

Horizontal deflection

Sweep speed

Horizontal zoom

Triggering

Mode

Type

Coupling

Sensitivity

Digital storage

Maximum sampling rate

Vertical resolution

Memory depth

User storage

File management

GLITCH mode

Display modes

Other functions

AUTOSET

FFT analyzer & MATH functions

Cursors

Automatic measurements

MULTIMETER MODE

General specifications

AC, DC and AC + DC voltages

Resistance

Other measurements

Single and three-phase power

HARMONIC ANALYSER MODE

Multi-channel analysis

Simultaneous measurements

LOGGER MODE

Acquisition

GENERAL SPECIFICATIONS

Configuration memories

Printing

PC communication – software link

Software

Mains power supply

Safety / EMC

Mechanical specifications

OX 9062OX 9102OX 9104OX 9304

7" WVGA color TFT LCD touch screen, 800x480 – LED backlighting (adjustable standby mode)

2,500 real acquisition points on screen - Vectors with interpolation

4 curves + 4 references – Split Screen & Full Screen modes

Touch screen – ANDROID-type icons and graphical commands – customizable channel colors

15 complete languages, menus & online help

60 MHz

2 isolated channels

100 MHz100 MHz

4 isolated channels

300 MHz

15 MHz, 1.5 MHz or 5 kHz bandwidth limiter

1 MΩ ± 0.5% , approx. 12 pF

600 V / CAT III (1,000V per Probix) – from 50 to 400 Hz – Probix safety connectors

16 ranges from 2.5 mV to 200 V/div and up to 156 µV/div in vertical zoom mode (12-bit converter) – Accuracy ± 2%

"One Click Winzoom" mode (12-bit converter and direct graphical zoom on screen) – x 16 max.

1 / 10 / 100 / 1,000 or any scaling – definition of measurement unit

35 ranges from 1 ns/div to 200 s/div., accuracy ± [50 ppm + 500 ps] – Roll mode from 100 ms to 200 s/div

"One Click Winzoom" system (direct graphical zoom on screen) x 1 to x 5 or x 100 – storage 100 kpts/channel

On all the channels: automatic, triggered, one-shot, auto level 50%

Edge, pulse width (16 ns-20 s), delay (48 ns to 20 s), counting (3 to 16,384 events) Continuous adjustment of Trigger position

AC, DC GND, HFR, LFR, noise – Level and Hold-Off adjustable from 64 ns to 15 s

≤ 1.2 division p-p up to 300 MHz

2.5 GS/s in one-shot mode on each channel (100 GS/s max. in ETS mode)

12 bits (vertical resolution 0.025 %)

100 kpts per channel and file viewer in the manager

Internal = 1 GB to store the files: trace, text, configuration, math functions, System memory: .pdf print files, .png image files

+ high-capacity removable µSD-Card: SD 2 GB, SDHC 4-32 GB and SDXC > 32 GB

Duration ≤ 2 ns – 500,000 Min/Max pairs

Envelope, vector, accumulation-, averaging (factors 2 to 64) – XY (vector) and Y(f)=FFT

Complete in under 5 s, with recognition of the channels – Frequency > 30 Hz

2,500-point FFT (Lin or Log) with measurement cursors – Functions + , - , x , / and mathematical function editor

2 or 3 cursors: simultaneous V and T with AUTO measurement: T1, T2, Dt, 1/Dt, dBV, Ph

Simultaneously with waveform, 20 automatic measurements per channel and on the 4 channels simultaneously with scroll

2 or 4 channels – 8,000 cts min/max/frequency/relative – TRMS – Time/date-stamped graphical recording in logger mode

600 mV to 600 VRMS, 800 mV to 800 VDC – VDC accuracy +/- (0.5 % + 25 D) – 200 kHz bandwidth

80 Ω to 32 MΩ – accuracy 0.5%R+ 25D – Quick continuity test < 10 ms

Temperature (HX0035 = KTC, HX0036 = Pt100) / Capacitance 5nF to 5mF / Frequency 200 kHz / Diode test 3.3 V

Active, Reactive and Apparent power values plus Power Factor simultaneously with the U & I measurements

2 or 4 (depending on model), 63 orders, fundamental frequency 40 to 450 Hz in auto or manual mode

Total Vrms, THD and selected order (% fundamental, phase, frequency, Vrms)

Duration: 20,000 s – Interval: 0.2 s – Files: 100,000 measurements

Not limited according to device - variable file sizes

Network printing via Ethernet/Wifi in .png format

Ethernet (100 baseT), WiFi-USB (device, 12 Mbs) – "ScopeNet" application software for PC

PC: Ethernet and USB, ScopeNet (remote control, data recovery, cursors and automatic measurements)

Android tablet – ScopeAdmin Fleet Administration utility

Li-Ion rechargeable battery (6,900mAH-40 Wh) – Battery life of up to 8 hrs – Adjustable standby mode

Adapter / 2-hour fast charger, universal 98-264 V / 50/60 Hz)

Safety as per IEC 61010-2-30, 2010 – 600V CAT III / 1000V CAT II – EMC as per EN61326-1, 2010

292.5 x 210.6 x 66.2 mm – 2.1 kg with batteries – IP54 protection

For Your Electrical/Power Test & Measurement Instruments

Call the AEMC

®

Instruments Technical Assistance Hotline for immediate consultation with an applications engineer: (800) 343-1391 (Ext. 351)

Chauvin Arnoux

®

, Inc. d.b.a AEMC

®

Instruments • 15 Faraday Dr. • Dover, NH 03820 USA • (800) 343-1391 • (508) 698-2115 • Fax (508) 698-2118

E-mail:**************| Export Department: +1 (603) 749-6434 x520 • Fax +1 (603) 740-7550 •E-mail:***************

-OX9000Series_1021 • Printed in the USA

© 2021 Chauvin Arnoux

®

, Inc. d.b.a. AEMC® Instruments

2024年9月29日发(作者:释芳润)

Oscilloscope

OX 9000 SERIES

isolated channels

4-in-1 Instrument

Oscilloscope

Multimeter

Analyzer

Logger

with the recorded files directly

viewable on screen

Safety

• All channels isolated from one another

and from the earth, 600V CAT III

Ergonomic

• Modern, high tech design which is

simple, compact and practical

Optimization

• of all tools; communication, storage

and operation

Our products are backed by over 125 years of experience in test and measurement

equipment, and encompass the latest international standards for quality and safety.

(800) 343-1391

ERGONOMICS

Designed to simplify use with one button access to most functions

In a housing tailor-made to be as compact as possible,

the mechanical design makes it possible to integrate

the hardware components in a small size with the

keypad benefits from new technology developed in

the automotive industry.

IP

54

Original

CHANNEL AND PARAMETER IDENTIFICATION

Each channel and related parameters are identified with identical

color against a black background for simpler, quicker viewing.

EASY ACCESS VIA TOUCH SCREEN

Intuitive icons are provided to facilitate their use, even with gloves on.

ADJUSTABLE STRAP

This helps to optimize operation of the oscilloscope in your hand

or on your shoulder when working in the field.

A stand is also available to vary the orientation of the oscilloscope

when it is placed on a bench. The oscilloscope can be safely left

unattended using the Kensington locking system.

NEW KEYPAD DESIGN FOR OPTIMUM USER COMFORT

Configuration and measurement displays are simple to access from

the front panel in one of these 5 specific areas: Utilities (brightness,

full screen, screenshot), Measurements, Vertical, Horizontal, Trigger.

LINE POWER OR LI-ION BATTERY

Port on left side.

Scope in carrying case with shoulder strap, set of two 5 ft color-coded leads, alligator clips

and test probes, 10 ft USB cable, µSD memory card, 1-PROBIX Banana Plug Adapter, 1 styli

pen, LI-ION 5.8 Ah battery pack, PA40W-2 power adapter with 110V power cord. Additional

accessories may be model dependent.

2 Technical Assistance (800) 343-1391

APPLICATIONS

Ideal for electronic and industrial maintenance

Electronic maintenance

The OX 9304 model is ideal for electronics with its

300 MHz bandwidth, 4 x 600V CAT III isolated channels,

advanced trigger functions, integrated FFT function,

complex mathematical calculations on the curves, automatic

measurements on 4 channels and the built-in WEB server.

IP54

Housing protected against dust and water spray.

7" WVGA WIDE COLOR TFT TOUCH SCREEN

Makes it easy to view and read the measurements clearly.

It also provides a screen resolution of 800 x 480 dpi with manual

or automatic brightness.

TOUCH-SCREEN STYLUS STORAGE

Among the essential tools available, the sylus is equipped with a

hook for the addition of a cord to make it captive, as required. One

end is slightly flattened to prevent rolling when placed on a table

or bench.

AUTOSET BUTTON

Quickly and effortlessly adjusts the horizontal and vertical;

sensitivity and scales to provide the best resolution.

Industrial maintenance

The OX 9304’s large 7-inch screen, 300 MHz bandwidth,

4 x 600V CAT III isolated channels and Harmonic

Analyzer and Multimeter modes make it ideal for

industrial maintenance applications.

DIRECT SETTING AND SET-UP BUTTONS

COMMUNICATION INTERFACES

These are isolated from one another and from the measurement

channels. A dedicated compartment on the right side protected

by a flexible cover contains all the different communication

interface ports:

USB host for communication with a PC

wired RJ45 or WiFi for communication with a PC or

µSD card for data storage with quick transfer and for

upgrading of the instrument's firmware

printing via a network printer

DIRECT ACCESS ZOOM BUTTON

Channels are isolated.

CATALOG NO. DESCRIPTION

2150.31 ....................................................................................................................................Hand-Held Oscilloscope Model OX 9062 IV 60MHz

2150.32 ..................................................................................................................................Hand-Held Oscilloscope Model OX 9102 IV 100MHz

2150.33 ..................................................................................................................................Hand-Held Oscilloscope Model OX 9104 IV 100MHz

2150.34 ..................................................................................................................................Hand-Held Oscilloscope Model OX 9304 IV 300MHz

Technical Assistance (800) 343-1391 3

OSCILLOSCOPE OX 9000 SERIES

ACCESSORIES

Accessories automatically recognized

when connected to the oscilloscope

The plug and play accessories included are

automatically recognized when connected to the

oscilloscope. They provide quick and easy

implementation with total user safety. Additionally,

accessories equipped with BNC connectors or

standard banana plugs can also be connected when

using the supplied adapter.

Interchangeable ID Markers can be used on the

accessories plugged into a given channel to identify them

with the trace color displayed on the screen.

Additionally the 10:1 probe accessory is equipped with

3 adjustable buttons to optimize its measurement capabilities.

PROBE FUNCTIONS

voltage measurements

• by probe with different

bandwidths and attenuation

• by BNC or banana jack connection

current measurements

• by AC or AC/DC current clamp

• directly through banana

jack connections

temperature measurements

• using a K thermocouple sensor

• using a PT100 RTD sensor

Identification and Safety Management

Once one of the provided standard accessories has been

plugged in, it is automatically identified and its

characteristics and calibration references are retrieved by

the OX9000 Series Oscilloscope. All accessories are

directly powered by the oscilloscope.

Channel Configuration and Sensor Management

Sensor coefficients scales and units of measure are managed

automatically, as is channel configuration. Control buttons on

the probes can be used to modify the settings of the channels

to which they are connected. They also offer functions

accessible on the oscilloscope's front panel.

Accessories & Replacements

Cat #2124.73 - PROBIX PRHX1 10:1 Probe, 250MHz 600V CAT III

Cat #2124.77 - PROBIX Current Probe, 20mA-20A 1MHz-3dB

Cat #5000.17 - Set of 5 styli pens

4 Technical Assistance (800) 343-1391

COMMUNICATION

For added equipment and operator safety all communication from the

instrument is totally isolated from the measurement process

Choice of communication interfaces―you can choose

the type of communicaton to fit your requirements.

Several communication choices are built into the OX9000

Series oscilloscope.

• Wired Ethernet LAN network with integrated DHCP

server for easy connection to your network

• WiFi® radio link to communicate with a PC, tablet or

smartphone using the dedicated interfaces

• USB for interfacing with the PC; record, recall or

load configurations

• µSD with >8 GB, default storage giving priority over

the 1 GB internal memory

Electrical Troubleshooting

File Management

Any of the signal traces can be displayed instantaneously as

the reference by pressing a single button which will obtain a

comparison an immediate measurements of the deviation of

ongoing measurements.

Backups are available in various formats for direct export into

a standard application such as Windows base spreadsheets

or word processors.

It is easy to take screenshots directly from the front panel and

save them in a .PNG format, print documents on a network

printer and transfer or delete files in the file manager.

Education

t

r

a

c

e

s

(

t

r

c

)

Storage capability

for each mode

s

e

t

u

p

(

c

f

g

)

Type of file

s

c

r

e

e

n

s

h

o

t

(

p

n

g

)

m

e

a

s

(

t

x

t

)

m

a

t

h

(

f

c

t

)

In the laboratory

Oscilloscope mode

Multimeter mode

Logger mode

Harmonics mode





Data Processing

• Use the oscilloscope screen to recall screenshots and

stored traces for direct review on screen

• On your PC, use the ScopeNet application in your web

browser with either the USB or Ethernet connection for

remote control and programming with SCPI commands

Technical Assistance (800) 343-1391 5

4 MODES: Oscilloscope, Multimeter, Analyzer, Recorder

Improved functions and performance levels of the OX9000 Series

• wider bandwidth up to 300 MHz

• new triggering and recording options

• increased storage capacity, and more!

• 12 bit resolution

• 2.5 GS/sec

OSCILLOSCOPE:

Trigger Functions

An oscilloscope with complex trigger functions

records what is necessary, while capturing all the faults

The OX9000 models offer advanced triggers which

complement the main edge trigger options: pulse width,

counting and delay.

• The Delay mode enables you to observe any

event with maximum resolution, even if it occurs

a long time after effective triggering, or on two

different channels.

• The Counting mode enables you to count the

events before triggering, so that you can check the

content of digital frames. For example, the trigger

can be linked to a second “auxiliary” signal which

is different from the “main” signal.

The Math Functions

In oscilloscope mode, the MATH functions (1, 2, 3

and 4) allow you to define a mathematical function

for each of the traces, along with vertical scaling and

labeling of the actual physical unit.

The mathematical editor is capable of displaying 4

calculated traces on which all the automatic or cursor

measurements remain available. This means it is

possible to examine the waveforms, such as the power

(V x I), and perform all the associated measurements.

A large number of operators are available, including +,

-, x and / , as well as more complex operators such as

sine, cosine, exponential, logarithm, square root, etc.

opening the way for specific applications.

Automatic Measurements

Comprehensive automatic measurements are displayed

with cursors for precise analysis. The automatic

measurements window displays all 20 parameters at

the touch of a button for 4 channels. Two horizontal

and vertical cursors can be used to view the section

of the signal where the first automatic measurement

was performed.

A specific measurement area can then be selected

by framing it with manual cursors for more accurate,

reliable results.

Direct comparison of two traces can be performed

by checking the “reference memory deviation” box,

so that these 20 signal parameters are displayed in

terms of deviations.

Real-time Fast Fourier Transform (FFT) for frequency

decomposition of your signals on 4 channels

The FFT is used to calculate, from 2500 points

upwards, the discrete representation of a signal in the

frequency domain from its representation in the time

domain. It is often particularly useful for arriving at an

effective diagnosis during qualitative analysis of

the signals:

• measurement of the individual harmonics or

distortion of a signal

• analysis of a pulse response

• search for the source of noise in the logic circuits

Several weighting windows are available, as well

as 2 representation modes: linear or logarithmic

(scale in dB). The 2 cursors can then be used for

precise measurements of the frequency lines, the

levels and the attenuations, taking advantage of

the 80 dB dynamic range allowed by the 12-bit /

2.5 GS/s conversion.

The autoset button makes it easier to obtain an

optimum spectral representation to which a graphical

zoom can be applied to analyze all the details of

the spectrum.

Technical Assistance (800) 343-13916

VIEW ALL 4 CHANNELS

waveform + XY

SIMULTANEOUSLY

waveform + zoom

waveform + FFT

4 MODES: Oscilloscope, Multimeter, Analyzer, Recorder

The four modes are directly accessed at the press of a button or touch

screen icon providing instant access the mode you need

Harmonic Analysis

Harmonic analysis is performed on all 4 channels up to

the 63rd order to comply with the requirements of the EN

50160 standard (THD on harmonics up to the 50th), with a

fundamental frequency between 40 and 450 Hz.

It is possible to preselect the frequency of the fundamental

for the standards (50 Hz, 60 Hz and 400 Hz).

This function helps to improve analytical performance and,

above all, measurement when the level of a harmonic order

is greater than the fundamental.

It is possible to view the harmonic analyses of two or four

channels simultaneously: RMS level, harmonic distortion,

harmonic frequency, phase of the harmonic in relation to

the fundamental.

Harmonics

4 Simultaneous Channels

Multimeter

By simply selecting the dedicated icons, you can gain access

to the multimeter mode without changing the measurement

input channels. The OX9000 models offer an 8,000-count

TRMS digital multimeter with two or four channels which can

perform the following measurements:

• amplitude (DC or AC voltage and current, power,

temperature, etc.)

• resistance, continuity, capacitance

• component diode tests

Temperature is measured using the Pt 100 and Pt 1000

sensors or K thermocouples via the dedicated PROBIX

sensors. The power measurements are proposed as follows

with choice of the configuration:

• single-phase power

• three-phase power on balanced network without neutral

• three-phase power on balanced network with neutral

• 3-wire three-phase power (2-wattmeters method)

Measurement between H and V cursors:

T1, T2, Dt, 1/Dt, V1, V2, dV, Ph

Recorder/logger

This is the mode for recording the trends in Multimeter mode. A genuine fast digital logger is provided inside the

instrument to monitor the variations of physical or mechanical phenomena over time. It offers acquisition intervals

as short as 40µs between 2 measurements and recording can cover any period from 2 seconds to one month.

Technical Assistance (800) 343-1391 7

TECHNICAL SPECIFICATIONS

HUMAN-MACHINE INTERFACE

Type of display

Different display mode

Display of curves on screen

Screen commands

Choice of language

OSCILLOSCOPE MODE

Vertical deflection

Bandwidth

Number of channels

Input impedance

Maximum input voltage

Vertical sensitivity

Vertical zoom

Probe factor (non-Probix)

Horizontal deflection

Sweep speed

Horizontal zoom

Triggering

Mode

Type

Coupling

Sensitivity

Digital storage

Maximum sampling rate

Vertical resolution

Memory depth

User storage

File management

GLITCH mode

Display modes

Other functions

AUTOSET

FFT analyzer & MATH functions

Cursors

Automatic measurements

MULTIMETER MODE

General specifications

AC, DC and AC + DC voltages

Resistance

Other measurements

Single and three-phase power

HARMONIC ANALYSER MODE

Multi-channel analysis

Simultaneous measurements

LOGGER MODE

Acquisition

GENERAL SPECIFICATIONS

Configuration memories

Printing

PC communication – software link

Software

Mains power supply

Safety / EMC

Mechanical specifications

OX 9062OX 9102OX 9104OX 9304

7" WVGA color TFT LCD touch screen, 800x480 – LED backlighting (adjustable standby mode)

2,500 real acquisition points on screen - Vectors with interpolation

4 curves + 4 references – Split Screen & Full Screen modes

Touch screen – ANDROID-type icons and graphical commands – customizable channel colors

15 complete languages, menus & online help

60 MHz

2 isolated channels

100 MHz100 MHz

4 isolated channels

300 MHz

15 MHz, 1.5 MHz or 5 kHz bandwidth limiter

1 MΩ ± 0.5% , approx. 12 pF

600 V / CAT III (1,000V per Probix) – from 50 to 400 Hz – Probix safety connectors

16 ranges from 2.5 mV to 200 V/div and up to 156 µV/div in vertical zoom mode (12-bit converter) – Accuracy ± 2%

"One Click Winzoom" mode (12-bit converter and direct graphical zoom on screen) – x 16 max.

1 / 10 / 100 / 1,000 or any scaling – definition of measurement unit

35 ranges from 1 ns/div to 200 s/div., accuracy ± [50 ppm + 500 ps] – Roll mode from 100 ms to 200 s/div

"One Click Winzoom" system (direct graphical zoom on screen) x 1 to x 5 or x 100 – storage 100 kpts/channel

On all the channels: automatic, triggered, one-shot, auto level 50%

Edge, pulse width (16 ns-20 s), delay (48 ns to 20 s), counting (3 to 16,384 events) Continuous adjustment of Trigger position

AC, DC GND, HFR, LFR, noise – Level and Hold-Off adjustable from 64 ns to 15 s

≤ 1.2 division p-p up to 300 MHz

2.5 GS/s in one-shot mode on each channel (100 GS/s max. in ETS mode)

12 bits (vertical resolution 0.025 %)

100 kpts per channel and file viewer in the manager

Internal = 1 GB to store the files: trace, text, configuration, math functions, System memory: .pdf print files, .png image files

+ high-capacity removable µSD-Card: SD 2 GB, SDHC 4-32 GB and SDXC > 32 GB

Duration ≤ 2 ns – 500,000 Min/Max pairs

Envelope, vector, accumulation-, averaging (factors 2 to 64) – XY (vector) and Y(f)=FFT

Complete in under 5 s, with recognition of the channels – Frequency > 30 Hz

2,500-point FFT (Lin or Log) with measurement cursors – Functions + , - , x , / and mathematical function editor

2 or 3 cursors: simultaneous V and T with AUTO measurement: T1, T2, Dt, 1/Dt, dBV, Ph

Simultaneously with waveform, 20 automatic measurements per channel and on the 4 channels simultaneously with scroll

2 or 4 channels – 8,000 cts min/max/frequency/relative – TRMS – Time/date-stamped graphical recording in logger mode

600 mV to 600 VRMS, 800 mV to 800 VDC – VDC accuracy +/- (0.5 % + 25 D) – 200 kHz bandwidth

80 Ω to 32 MΩ – accuracy 0.5%R+ 25D – Quick continuity test < 10 ms

Temperature (HX0035 = KTC, HX0036 = Pt100) / Capacitance 5nF to 5mF / Frequency 200 kHz / Diode test 3.3 V

Active, Reactive and Apparent power values plus Power Factor simultaneously with the U & I measurements

2 or 4 (depending on model), 63 orders, fundamental frequency 40 to 450 Hz in auto or manual mode

Total Vrms, THD and selected order (% fundamental, phase, frequency, Vrms)

Duration: 20,000 s – Interval: 0.2 s – Files: 100,000 measurements

Not limited according to device - variable file sizes

Network printing via Ethernet/Wifi in .png format

Ethernet (100 baseT), WiFi-USB (device, 12 Mbs) – "ScopeNet" application software for PC

PC: Ethernet and USB, ScopeNet (remote control, data recovery, cursors and automatic measurements)

Android tablet – ScopeAdmin Fleet Administration utility

Li-Ion rechargeable battery (6,900mAH-40 Wh) – Battery life of up to 8 hrs – Adjustable standby mode

Adapter / 2-hour fast charger, universal 98-264 V / 50/60 Hz)

Safety as per IEC 61010-2-30, 2010 – 600V CAT III / 1000V CAT II – EMC as per EN61326-1, 2010

292.5 x 210.6 x 66.2 mm – 2.1 kg with batteries – IP54 protection

For Your Electrical/Power Test & Measurement Instruments

Call the AEMC

®

Instruments Technical Assistance Hotline for immediate consultation with an applications engineer: (800) 343-1391 (Ext. 351)

Chauvin Arnoux

®

, Inc. d.b.a AEMC

®

Instruments • 15 Faraday Dr. • Dover, NH 03820 USA • (800) 343-1391 • (508) 698-2115 • Fax (508) 698-2118

E-mail:**************| Export Department: +1 (603) 749-6434 x520 • Fax +1 (603) 740-7550 •E-mail:***************

-OX9000Series_1021 • Printed in the USA

© 2021 Chauvin Arnoux

®

, Inc. d.b.a. AEMC® Instruments

发布评论

评论列表 (0)

  1. 暂无评论