JUMO safetyM TB/TW Temperature
limiter, temperature monitor
according DIN EN 14597
with LCD for mounting on 35mm DIN rails
Brief description
The JUMO safetyM TB/TW is a freely programmable temperature limiting device.
The measurement input is freely configurable for RTD temperature probes and thermocouples,
as well as for current and voltage signals.
TB/TWs monitor thermal processes in systems for a set limit value.
If this is exceeded, the
built-in relay (with internal fuse) switches the system to a safe operational state and the LED K1
switches from green to red.
When the system returns to the o.k. region, the reset button (on the TB) has to be released
manually using an appropriate tool.
The TW, on the other hand, is reset automatically without any external action.
The binary output 24V/20mA produces a pre-alarm signal at an adjustable temperature before
reaching the limit value, which is additionally indicated via the LED KV.
TB/TWs are mounted on DIN rails and wired up by means of screw terminals with 2.5mm²
max. conductor cross-section.
A PC setup program is available as an accessory, which can be used to set and store probe
type, range, output action and inhibits.
Typ 701160/ …
Block diagram
Special features
kSetup program for configuration and
archive data backup
kClear, easy-to-read alphanumerical display
kDigital input filter with adjustable
filter time constant
k adjustable as absolute value or relative to
limit value
kWide supply voltage range
110 — 240V AC +10% /-15%
kConfigurable as TB or TW
k17 linearizations can be set
kInternal and external locking options
kinput 2 x Pt100 for differential measure-
ment
Approval/approval marks
(see technical data)
2015-03-01/00506174
Technical data
Analog inputs
RTD temperature probe
Designation
Pt 100 EN 60751
KTY11-6 PTC
Pt 1000 DIN
connection types
Sampling
Input filter
Special features
thermocouples
Measuring range
-200…+850°C
-50...150°C
-200…+850°C
2-wire, 3-wire circuits
210ms
Accuracy
1
0.1%
1%
0.1%
2nd order digital filter; filter constant adjustable from 0to100secs
2x Pt100 for differential measurement, display can also be programmed in °F
Designation
Fe-CuNi "L" DIN 43710
Fe-CuNi "J" EN 60584
Cu-CuNi "U" DIN 43710
Cu-CuNi "T" EN 60584
NiCr-Ni "K" EN 60584
NiCrSi-NiSi "N" EN 60584
Pt10Rh-Pt "S" EN 60584
Pt13Rh-Pt "R" EN 60584
Pt30Rh-Pt6Rh "B" EN 60584
W3Re-W25Re "D"
Cold junction
Cold junction accuracy
Sampling rate
Input filter
Special features
Measuring range
-200to+900°C
-200to+1200°C
-200to+600°C
-200to+400°C
-200to+1372°C
-100to+1300°C
0to+1768°C
0to+1768°C
300to1820°C
0...2495°C
Pt 100, internal
± 1K
210 ms
Accuracy
1
0.4%
0.4%
0.4%
0.4%
0.4%
0.4%
0.4%
0.4%
0.4%
0.4%
2nd order digital filter; filter constant adjustable from 0to100secs
also programmable in °F
1. Accuracy refers to the maximum extent of the measuring range.
If the measuring range is smaller, the linearisation accuracy is reduced .
DC voltage, DC current
Measuring range
0to20mA, voltage drop < 2 V
4to20mA, voltage drop < 2 V
0to10V, input resistance > 100 kΩ
2to10V, input resistance > 100 kW
Scaling
Sampling rate
Input filter
Accuracy
0.2%
0.1%
freely programmable within the limits
210 ms
2nd order digital filter; filter constant adjustable from 0to100secs
Measuring circuit monitoring
RTD temperature probe
and KTY11-6
Twin thermocouplesThermocouplesCurrent 0 to 20 mA, 4 to 20mA
Voltage 0 to 10 V, 2 to 10 V
Overrange and un-is detected
derrangeLEDs K1 and KV light up; "1999" flashes in the display
Probe and lead breakis detected
LEDs K1 and KV light up; "1999" flashes in the display; relay K1 is active.
Probe short circuitis detected
LEDs K1 and KV light up;"1999" flashes in the display
Relay K1 is inactive
is not detected
is detected at 4 to 20mA
and 2 to 10V
LEDs K1 and KV light up;
"1999" flashes in the display
Relay K1 is inactive
2015-03-01/00506174
Binary input
connection
1 floating contact
Function
Configurable unlocking, keyboard inhibit, level inhibit
Relay- and Binary output
1 relay100000 operations at a contact rating of:
AC 230/24V; 3(0,5)A; cosφ=1 (≥ 0,6); 50Hz
DC 24V; 3(0,5; τ=7ms)A
UL60730
AC230V; 3A
D300; 30k
AC/DC 24V; 3A, minimum current: DC 24V, 100mA
Contact protection circuit:
safety fuse 3.15AT, installed in the pole contact arm within the instrument
24 V DC / 20mA logic signal, short-circuit proof1 Binary output
Voltage supply
voltage supply
Power consumption
20 - 30V AC/DC, 48 ...63 Hz
110V/240V AC, +10% /-15%
5 VA
Aapproval/Marks
approval
marks
DIN
c UL us
Inspection authority
DIN CERTCO
Certificate/Inspection
numbers
TW/TB 1206 08
inspection basics
DIN EN 14597
UL 60730-2-9
valid for
all instrument versions
all instrument versionsUnderwriters Laboratories20091123-E325456
Switching action at limit value
Switching action inverse
Switching action direct
2015-03-01/00506174
Switching action at differential measurement
Switching action inverse
Test voltages to EN 60730, Part 1
Between input or output and supply
- at 110-240 V AC supply +10% /-15%
- at 20 - 30V AC/DC supply, 48 - 63 Hz
3.7kV/50Hz
3.7kV/50Hz
Electrical safety
Clearances / creep paths
Mains to electronic components and probe
Mains to the relay
Relay to electronic components and probe
Electrical safety
Protection type I
≥
6 mm
/ ≥
8 mm
≥
6 mm
/ ≥
8 mm
≥
6 mm
/ ≥
8 mm
according to DIN EN 14597 (DIN EN 60730-2-9)
Overvoltage category III, pollution degree 2
with internal separation to SELV current circuits
Environmental influences
Ambient temperature range
Storage temperature range
Temperature error
Climatic conditions
EMC
Interference emission
Interference immunity
details refer to the full scale value
0...+55°C
-30...+70°C
≤ ± 0.005% / K dev. from 23°C
1
for resistance thermometers
≤ ± 0.01% / K dev. from 23°C
1
for thermocouple, current, voltage
85% rel. humidity, no condensation
(3K3 with extended temperature range to EN 60721)
to EN 14597 and standards from the EN 61326 series of standards
Class B
Test level for safety, control and regulating instruments (RS) to EN 14597
Housing
Material
Screw terminal
Mounting
mounting position
Weight
Protection type
polyamide (PA 6.6)
0.2-2.5mm
2
screw terminal
on 35mmx7.5mm DIN rail to EN 60715
vertical
approx. 160g
IP 20 to EN 60529
2015-03-01/00506174
Dimensions
Type 701160/...
DIN-approved probes for operation in air
Note: Because of the high response accuracy, the use of thermowells (pockets) is not admissible.
Actual type designation
RTD temperature probe Data Sheet 90.2006
902006/65-228-1003-1-15-500-668/000
902006/65-228-1003-1-15-710-668/000
902006/65-228-1003-1-15-1000-668/000
902006/55-228-1003-1-15-500-254/000
902006/55-228-1003-1-15-710-254/000
902006/55-228-1003-1-15-1000-254/000
902006/65-228-2003-1-15-500-668/000
902006/65-228-2003-1-15-710-668/000
902006/65-228-2003-1-15-1000-668/000
902006/55-228-2003-1-15-500-254/000
902006/55-228-2003-1-15-710-254/000
902006/55-228-2003-1-15-1000-254/000
Thermocouples Data Sheet 90.1006
901006/65-547-2043-15-500-668/000
901006/65-547-2043-15-710-668/000
901006/65-547-2043-15-1000-668/000
901006/65-546-2042-15-500-668/000
901006/65-546-2042-15-710-668/000
901006/65-546-2042-15-1000-668/000
901006/66-550-2043-6-500-668/000
901006/66-550-2043-6-355-668/000
901006/66-550-2043-6-250-668/000
901006/66-880-1044-6-250-668/000
901006/66-880-1044-6-355-668/000
901006/66-880-1044-6-500-668/000
901006/66-880-2044-6-250-668/000
901006/66-880-2044-6-355-668/000
901006/66-880-2044-6-500-668/000
90.019-F01
90.020-F01
90.021-F01
90.019-F11
90.020-F11
90.021-F11
90.023-F01
90.023-F02
90.023-F03
90.021
90.022
90.023
90-D-021
90-D-022
90-D-023
2 x PT10Rh-PT, TypE „S“0 ... 1300°C
1 x PT10Rh-PT, TypE „S“0 ... 1300°C
2 x NiCr-Ni, TypE „K“-35 ... +1000°C
2 x Fe-CuNi, TypE „L“-35 ... +700°C
2 x NiCr-Ni, TypE „K“-35 ... +800°C
500
710
1000
500
710
1000
500
355
250
250
355
500
250
355
500
Stop flange,
movable
Stop flange,
movable
-
-
-
-
-
-
90.271-F01
90.272-F01
90.273-F01
-
-
-
2 x Pt100-170 ... +700°C
2 x Pt100-170 ... +700°C
1 x Pt100-170 ... +700°C
1 x Pt100-170 ... +700°C500
710
1000
500
710
1000
500
710
1000
500
710
1000
movable
G1/2 compression
clamp
Stop flange,
movable
Old type
designation
Probe typeTemperature rangeNom. length mm
P
rocess connection
901006/66-953-1046-6-250-668/000
901006/66-953-1046-6-355-668/000
901006/66-953-1046-6-500-668/000
901006/66-953-2046-6-250-668/000
901006/66-953-2046-6-355-668/000
901006/66-953-2046-6-500-668/000
90.027
90.028
90.029
90-D-027
90-D-028
90-D-029
1 x PT30Rh-PT6Rh, TypE „B“600 ... 1500°C250
355
500
2 x PT30Rh-PT6Rh, TypE „B“600 ... 1500°C250
355
500
2015-03-01/00506174
DIN-approved probes for operation in water and oil
Note: Because of the high response accuracy, the use of thermowells (pockets) is not admissible.
Actual type designation
RTD temperature probe Data Sheet 90.2006
90.2006/10-402-1003-1-9-100-104/000
90.2006/10-402-2003-1-9-100-104/000
902006/54-227-2003-1-15-710-254/000
902006/54-227-1003-1-15-710-254/000
902006/10-226-1003-1-9-250-104/000
902006/10-226-2003-1-9-250-104/000
Thermocouples Data Sheet 90.1006
901006/54-544-2043-15-710-254/000
901006/54-544-1043-15-710-254/000
901006/54-544-2042-15-710-254/000
901006/54-544-1042-15-710-254/000
90.020-F02
90.020-F03
90.020-F12
90.020-F13
2 x NiCr-Ni, Type „K“
1 x NiCr-Ni, Type „K“
2 x FeCuNi, Type „L“
1 x FeCuNi, Type „L“
-35 ... 550°670
65...670
65...670
65...670
movable
G1/2 compression clamp
90.272-F02
90.272-F03
90.239
90-D-239
1 x Pt100
2 x Pt100
2 x Pt100
1 x Pt100
1 x Pt100
2 x Pt100
-170 ... 480°C
-170 ... 550°C
-40 ... +400°C100
100
65...670
65...670
250
250
movable
G1/2 compression clamp
G1/2 screw connection
G1/2 screw connection
Old type
designation
Probe typeTemperature rangeNom. length mm
P
rocess connection
DIN-approved probes for operation in water and oil
Note: Because of the high response accuracy, the use of thermowells (pockets) is not admissible.
Actual type designation
RTD temperature probe Data Sheet 90.2006
90.2006/10-402-1003-1-9-100-104/000
90.2006/10-402-2003-1-9-100-104/000
902006/54-227-2003-1-15-710-254/000
902006/54-227-1003-1-15-710-254/000
902006/10-226-1003-1-9-250-104/000
902006/10-226-2003-1-9-250-104/000
Thermocouples Data Sheet 90.1006
901006/54-544-2043-15-710-254/000
901006/54-544-1043-15-710-254/000
901006/54-544-2042-15-710-254/000
901006/54-544-1042-15-710-254/000
90.020-F02
90.020-F03
90.020-F12
90.020-F13
2 x NiCr-Ni, Type „K“
1 x NiCr-Ni, Type „K“
2 x FeCuNi, Type „L“
1 x FeCuNi, Type „L“
-35 ... 550°670
65...670
65...670
65...670
movable
G1/2 compression clamp
90.272-F02
90.272-F03
90.239
90-D-239
1 x Pt100
2 x Pt100
2 x Pt100
1 x Pt100
1 x Pt100
2 x Pt100
-170 ... 480°C
-170 ... 550°C
-40 ... +400°C100
100
65...670
65...670
250
250
movable
G1/2 compression clamp
G1/2 screw connection
G1/2 screw connection
Old type
designation
Probe typeTemperature rangeNom. length mm
P
rocess connection
DIN-approved probes for operation air, water and oil
Note: Because of the high response accuracy, the use of thermowells (pockets) is not admissible.
Actual type designation
RTD temperature probe Data Sheet 90.2006
90.2006/10-390-1003-1-8-250-104/000
Thermocouples Data Sheet 90.1006
901006/45-551-2043-2-xxxx-11-xxxx2 x NiCr-Ni, Typ
E „K“
max. 1
2024年10月18日发(作者:严含文)
JUMO GmbH & Co. KG
Delivery address:Mackenrodtstraße 14,
36039 Fulda, Germany
Postal address:36035 Fulda, Germany
Phone:+49 661 6003-0
Fax:+49 661 6003-607
e-mail:*************
Internet:
JUMO Instrument Co. Ltd.
JUMO House
Temple Bank, Riverway
Harlow, Essex CM 20 2TT, UK
Phone:+44 1279 635533
Fax:+44 1279 635262
e-mail:*************.uk
Internet:
JUMO Process Control, Inc.
8 Technology Boulevard
Canastota, NY 13032, USA
Phone:315-697-JUMO
1-800-554-JUMO
Fax:315-697-5867
e-mail:************
Internet:
Seite 1/8
JUMO safetyM TB/TW Temperature
limiter, temperature monitor
according DIN EN 14597
with LCD for mounting on 35mm DIN rails
Brief description
The JUMO safetyM TB/TW is a freely programmable temperature limiting device.
The measurement input is freely configurable for RTD temperature probes and thermocouples,
as well as for current and voltage signals.
TB/TWs monitor thermal processes in systems for a set limit value.
If this is exceeded, the
built-in relay (with internal fuse) switches the system to a safe operational state and the LED K1
switches from green to red.
When the system returns to the o.k. region, the reset button (on the TB) has to be released
manually using an appropriate tool.
The TW, on the other hand, is reset automatically without any external action.
The binary output 24V/20mA produces a pre-alarm signal at an adjustable temperature before
reaching the limit value, which is additionally indicated via the LED KV.
TB/TWs are mounted on DIN rails and wired up by means of screw terminals with 2.5mm²
max. conductor cross-section.
A PC setup program is available as an accessory, which can be used to set and store probe
type, range, output action and inhibits.
Typ 701160/ …
Block diagram
Special features
kSetup program for configuration and
archive data backup
kClear, easy-to-read alphanumerical display
kDigital input filter with adjustable
filter time constant
k adjustable as absolute value or relative to
limit value
kWide supply voltage range
110 — 240V AC +10% /-15%
kConfigurable as TB or TW
k17 linearizations can be set
kInternal and external locking options
kinput 2 x Pt100 for differential measure-
ment
Approval/approval marks
(see technical data)
2015-03-01/00506174
Technical data
Analog inputs
RTD temperature probe
Designation
Pt 100 EN 60751
KTY11-6 PTC
Pt 1000 DIN
connection types
Sampling
Input filter
Special features
thermocouples
Measuring range
-200…+850°C
-50...150°C
-200…+850°C
2-wire, 3-wire circuits
210ms
Accuracy
1
0.1%
1%
0.1%
2nd order digital filter; filter constant adjustable from 0to100secs
2x Pt100 for differential measurement, display can also be programmed in °F
Designation
Fe-CuNi "L" DIN 43710
Fe-CuNi "J" EN 60584
Cu-CuNi "U" DIN 43710
Cu-CuNi "T" EN 60584
NiCr-Ni "K" EN 60584
NiCrSi-NiSi "N" EN 60584
Pt10Rh-Pt "S" EN 60584
Pt13Rh-Pt "R" EN 60584
Pt30Rh-Pt6Rh "B" EN 60584
W3Re-W25Re "D"
Cold junction
Cold junction accuracy
Sampling rate
Input filter
Special features
Measuring range
-200to+900°C
-200to+1200°C
-200to+600°C
-200to+400°C
-200to+1372°C
-100to+1300°C
0to+1768°C
0to+1768°C
300to1820°C
0...2495°C
Pt 100, internal
± 1K
210 ms
Accuracy
1
0.4%
0.4%
0.4%
0.4%
0.4%
0.4%
0.4%
0.4%
0.4%
0.4%
2nd order digital filter; filter constant adjustable from 0to100secs
also programmable in °F
1. Accuracy refers to the maximum extent of the measuring range.
If the measuring range is smaller, the linearisation accuracy is reduced .
DC voltage, DC current
Measuring range
0to20mA, voltage drop < 2 V
4to20mA, voltage drop < 2 V
0to10V, input resistance > 100 kΩ
2to10V, input resistance > 100 kW
Scaling
Sampling rate
Input filter
Accuracy
0.2%
0.1%
freely programmable within the limits
210 ms
2nd order digital filter; filter constant adjustable from 0to100secs
Measuring circuit monitoring
RTD temperature probe
and KTY11-6
Twin thermocouplesThermocouplesCurrent 0 to 20 mA, 4 to 20mA
Voltage 0 to 10 V, 2 to 10 V
Overrange and un-is detected
derrangeLEDs K1 and KV light up; "1999" flashes in the display
Probe and lead breakis detected
LEDs K1 and KV light up; "1999" flashes in the display; relay K1 is active.
Probe short circuitis detected
LEDs K1 and KV light up;"1999" flashes in the display
Relay K1 is inactive
is not detected
is detected at 4 to 20mA
and 2 to 10V
LEDs K1 and KV light up;
"1999" flashes in the display
Relay K1 is inactive
2015-03-01/00506174
Binary input
connection
1 floating contact
Function
Configurable unlocking, keyboard inhibit, level inhibit
Relay- and Binary output
1 relay100000 operations at a contact rating of:
AC 230/24V; 3(0,5)A; cosφ=1 (≥ 0,6); 50Hz
DC 24V; 3(0,5; τ=7ms)A
UL60730
AC230V; 3A
D300; 30k
AC/DC 24V; 3A, minimum current: DC 24V, 100mA
Contact protection circuit:
safety fuse 3.15AT, installed in the pole contact arm within the instrument
24 V DC / 20mA logic signal, short-circuit proof1 Binary output
Voltage supply
voltage supply
Power consumption
20 - 30V AC/DC, 48 ...63 Hz
110V/240V AC, +10% /-15%
5 VA
Aapproval/Marks
approval
marks
DIN
c UL us
Inspection authority
DIN CERTCO
Certificate/Inspection
numbers
TW/TB 1206 08
inspection basics
DIN EN 14597
UL 60730-2-9
valid for
all instrument versions
all instrument versionsUnderwriters Laboratories20091123-E325456
Switching action at limit value
Switching action inverse
Switching action direct
2015-03-01/00506174
Switching action at differential measurement
Switching action inverse
Test voltages to EN 60730, Part 1
Between input or output and supply
- at 110-240 V AC supply +10% /-15%
- at 20 - 30V AC/DC supply, 48 - 63 Hz
3.7kV/50Hz
3.7kV/50Hz
Electrical safety
Clearances / creep paths
Mains to electronic components and probe
Mains to the relay
Relay to electronic components and probe
Electrical safety
Protection type I
≥
6 mm
/ ≥
8 mm
≥
6 mm
/ ≥
8 mm
≥
6 mm
/ ≥
8 mm
according to DIN EN 14597 (DIN EN 60730-2-9)
Overvoltage category III, pollution degree 2
with internal separation to SELV current circuits
Environmental influences
Ambient temperature range
Storage temperature range
Temperature error
Climatic conditions
EMC
Interference emission
Interference immunity
details refer to the full scale value
0...+55°C
-30...+70°C
≤ ± 0.005% / K dev. from 23°C
1
for resistance thermometers
≤ ± 0.01% / K dev. from 23°C
1
for thermocouple, current, voltage
85% rel. humidity, no condensation
(3K3 with extended temperature range to EN 60721)
to EN 14597 and standards from the EN 61326 series of standards
Class B
Test level for safety, control and regulating instruments (RS) to EN 14597
Housing
Material
Screw terminal
Mounting
mounting position
Weight
Protection type
polyamide (PA 6.6)
0.2-2.5mm
2
screw terminal
on 35mmx7.5mm DIN rail to EN 60715
vertical
approx. 160g
IP 20 to EN 60529
2015-03-01/00506174
Dimensions
Type 701160/...
DIN-approved probes for operation in air
Note: Because of the high response accuracy, the use of thermowells (pockets) is not admissible.
Actual type designation
RTD temperature probe Data Sheet 90.2006
902006/65-228-1003-1-15-500-668/000
902006/65-228-1003-1-15-710-668/000
902006/65-228-1003-1-15-1000-668/000
902006/55-228-1003-1-15-500-254/000
902006/55-228-1003-1-15-710-254/000
902006/55-228-1003-1-15-1000-254/000
902006/65-228-2003-1-15-500-668/000
902006/65-228-2003-1-15-710-668/000
902006/65-228-2003-1-15-1000-668/000
902006/55-228-2003-1-15-500-254/000
902006/55-228-2003-1-15-710-254/000
902006/55-228-2003-1-15-1000-254/000
Thermocouples Data Sheet 90.1006
901006/65-547-2043-15-500-668/000
901006/65-547-2043-15-710-668/000
901006/65-547-2043-15-1000-668/000
901006/65-546-2042-15-500-668/000
901006/65-546-2042-15-710-668/000
901006/65-546-2042-15-1000-668/000
901006/66-550-2043-6-500-668/000
901006/66-550-2043-6-355-668/000
901006/66-550-2043-6-250-668/000
901006/66-880-1044-6-250-668/000
901006/66-880-1044-6-355-668/000
901006/66-880-1044-6-500-668/000
901006/66-880-2044-6-250-668/000
901006/66-880-2044-6-355-668/000
901006/66-880-2044-6-500-668/000
90.019-F01
90.020-F01
90.021-F01
90.019-F11
90.020-F11
90.021-F11
90.023-F01
90.023-F02
90.023-F03
90.021
90.022
90.023
90-D-021
90-D-022
90-D-023
2 x PT10Rh-PT, TypE „S“0 ... 1300°C
1 x PT10Rh-PT, TypE „S“0 ... 1300°C
2 x NiCr-Ni, TypE „K“-35 ... +1000°C
2 x Fe-CuNi, TypE „L“-35 ... +700°C
2 x NiCr-Ni, TypE „K“-35 ... +800°C
500
710
1000
500
710
1000
500
355
250
250
355
500
250
355
500
Stop flange,
movable
Stop flange,
movable
-
-
-
-
-
-
90.271-F01
90.272-F01
90.273-F01
-
-
-
2 x Pt100-170 ... +700°C
2 x Pt100-170 ... +700°C
1 x Pt100-170 ... +700°C
1 x Pt100-170 ... +700°C500
710
1000
500
710
1000
500
710
1000
500
710
1000
movable
G1/2 compression
clamp
Stop flange,
movable
Old type
designation
Probe typeTemperature rangeNom. length mm
P
rocess connection
901006/66-953-1046-6-250-668/000
901006/66-953-1046-6-355-668/000
901006/66-953-1046-6-500-668/000
901006/66-953-2046-6-250-668/000
901006/66-953-2046-6-355-668/000
901006/66-953-2046-6-500-668/000
90.027
90.028
90.029
90-D-027
90-D-028
90-D-029
1 x PT30Rh-PT6Rh, TypE „B“600 ... 1500°C250
355
500
2 x PT30Rh-PT6Rh, TypE „B“600 ... 1500°C250
355
500
2015-03-01/00506174
DIN-approved probes for operation in water and oil
Note: Because of the high response accuracy, the use of thermowells (pockets) is not admissible.
Actual type designation
RTD temperature probe Data Sheet 90.2006
90.2006/10-402-1003-1-9-100-104/000
90.2006/10-402-2003-1-9-100-104/000
902006/54-227-2003-1-15-710-254/000
902006/54-227-1003-1-15-710-254/000
902006/10-226-1003-1-9-250-104/000
902006/10-226-2003-1-9-250-104/000
Thermocouples Data Sheet 90.1006
901006/54-544-2043-15-710-254/000
901006/54-544-1043-15-710-254/000
901006/54-544-2042-15-710-254/000
901006/54-544-1042-15-710-254/000
90.020-F02
90.020-F03
90.020-F12
90.020-F13
2 x NiCr-Ni, Type „K“
1 x NiCr-Ni, Type „K“
2 x FeCuNi, Type „L“
1 x FeCuNi, Type „L“
-35 ... 550°670
65...670
65...670
65...670
movable
G1/2 compression clamp
90.272-F02
90.272-F03
90.239
90-D-239
1 x Pt100
2 x Pt100
2 x Pt100
1 x Pt100
1 x Pt100
2 x Pt100
-170 ... 480°C
-170 ... 550°C
-40 ... +400°C100
100
65...670
65...670
250
250
movable
G1/2 compression clamp
G1/2 screw connection
G1/2 screw connection
Old type
designation
Probe typeTemperature rangeNom. length mm
P
rocess connection
DIN-approved probes for operation in water and oil
Note: Because of the high response accuracy, the use of thermowells (pockets) is not admissible.
Actual type designation
RTD temperature probe Data Sheet 90.2006
90.2006/10-402-1003-1-9-100-104/000
90.2006/10-402-2003-1-9-100-104/000
902006/54-227-2003-1-15-710-254/000
902006/54-227-1003-1-15-710-254/000
902006/10-226-1003-1-9-250-104/000
902006/10-226-2003-1-9-250-104/000
Thermocouples Data Sheet 90.1006
901006/54-544-2043-15-710-254/000
901006/54-544-1043-15-710-254/000
901006/54-544-2042-15-710-254/000
901006/54-544-1042-15-710-254/000
90.020-F02
90.020-F03
90.020-F12
90.020-F13
2 x NiCr-Ni, Type „K“
1 x NiCr-Ni, Type „K“
2 x FeCuNi, Type „L“
1 x FeCuNi, Type „L“
-35 ... 550°670
65...670
65...670
65...670
movable
G1/2 compression clamp
90.272-F02
90.272-F03
90.239
90-D-239
1 x Pt100
2 x Pt100
2 x Pt100
1 x Pt100
1 x Pt100
2 x Pt100
-170 ... 480°C
-170 ... 550°C
-40 ... +400°C100
100
65...670
65...670
250
250
movable
G1/2 compression clamp
G1/2 screw connection
G1/2 screw connection
Old type
designation
Probe typeTemperature rangeNom. length mm
P
rocess connection
DIN-approved probes for operation air, water and oil
Note: Because of the high response accuracy, the use of thermowells (pockets) is not admissible.
Actual type designation
RTD temperature probe Data Sheet 90.2006
90.2006/10-390-1003-1-8-250-104/000
Thermocouples Data Sheet 90.1006
901006/45-551-2043-2-xxxx-11-xxxx2 x NiCr-Ni, Typ
E „K“
max. 1