MX5000
APC Matrix-UPS 5kVA 208V/240V In
120/208/240V Out
APC Matrix-UPS, 3750 Watts / 5000
VA,Input 208V / Output 120V, 208V, Interface
Port DB-9 RS-232, SmartSlot, Extended runtime
model
Includes
: CD with software, Smart UPS
signalling RS-232 cable, User Manual
Standard Lead Time
: Usually Ships within 2
Weeks
Matrix-UPS Features & Benefits
Availability
Automatic internal
bypass
Intelligent Battery
Management
Hot-swappable
batteries
Hot-swappable
Supplies utility power to the connected loads in the event of a UPS overload
condition or fault.
Maximizes battery performance, life, and reliability through intelligent,
precision charging.
Ensures clean, uninterrupted power to protected equipment while batteries
are being replaced
Ensures clean, uninterrupted power to protected equipment during Power
modules Module replacement.
Scalable runtime Allows additional run time to be quickly added as needed.
Automatic self-test Periodic battery self-test ensures early detection of a battery that needs to be
replaced.
Manageable external Reduces preventative maintenance service needs by monitoring the health
batteries and status of the external batteries and their expected runtime.
Battery modules Delivers higher availability through redundant batteries.
connected in parallel
Automatic restart of Automatically starts up the connected equipment upon the return of utility
loads after UPS power.
shutdown
Modular design Provides fast serviceability and reduced maintenance requirements via self-
diagnosing, field-replaceable modules.
Adaptability
Adjustable voltage-Maximizes useful battery life by widening the input voltage window or
transfer points tightening the output voltage regulation.
Plug-and-Play external Ensures clean, uninterrupted power to the loads when adding extra runtime to
batteries the UPS.
Field-replaceable Ensures compatibility with equipment that has different plug types.
power distribution
panel
Manageability
SmartSlot Customize UPS capabilities with management cards.
LCD display Alpha-Numeric Display which displays system parameters and alarms.
Serial Connectivity Provides management of the UPS via a serial port.
InfraStruXure Enables centralized management via the APC InfraStruXure® Manager.
Manager Compatible
Serviceability
User-replaceable Increases availability by allowing a trained user to perform upgrades and
batteries replacements of the batteries reducing Mean Time to Repair (MTTR)
Predictive failure Provides early-warning fault analysis ensuring proactive component
notification replacement.
User-replaceable Increases availability by allowing a trained user to perform upgrades and
batteries replacements of the batteries reducing Mean Time to Repair (MTTR)
User-replaceable Enables simple upgrades and replacements of the Power Modules.
power modules
Audible Alarms Actively let you know if the unit is on battery, if the battery is low or if there
is an overload condition.
Protection
Power conditioning
Boost and Trim
Automatic Voltage
Regulation (AVR)
Protects connected loads from surges, spikes, lightning, and other power
disturbances.
Gives higher application availability by correcting low and high voltage
conditions without using the battery.
Output
Output Power Capacity
Max Configurable Power
Nominal Output Voltage
Efficiency at Full Load
Output Voltage Distortion
Crest Factor
Waveform Type
Output Connections
3750 Watts / 5000 VA
3750 Watts / 5000 VA
120V,208V
93%
Less than 5% at full load
up to 5 : 1
Sine wave
(6) NEMA 5-15R
(1) NEMA L14-30R
(2) NEMA L6-30R
Bypass Internal Bypass (Automatic and Manual)
Output Frequency (sync to mains) 57 - 63 Hz for 60 Hz nominal
Input
Nominal Input Voltage
Input Frequency
Input Connections
Cord Length
Input voltage range for main
operations
Other Input Voltages
208V
60 Hz +/- 5 Hz
NEMA L6-30P
1.83 meters
156 - 252 (208) / 176 - 282 ( 240V)V
240
Batteries & Runtime
Battery Type
Typical recharge time
RBC™ Quantity
Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof
3.30 hour(s)
2
Replacement battery cartridge note The MX5000 ships with 2-SmartCell's. There is no RBC available for a standard
SmartCell. If a SmartCell-XR is being used,then an RBC14 may be purchased.
Typical Backup Time
at Half Load
Typical Backup Time
27.8 minutes (1875 Watts)
10.2 minutes (3750 Watts)
at Full Load
Runtime Chart
Extended Run Options
Matrix-UPS
APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out
Communications & Management
Interface Port(s)
Available SmartSlot™ Interface
Quantity
Control panel
Audible Alarm
Emergency Power Off (EPO)
DB-9 RS-232,SmartSlot
1
Multi-function LCD status and control console
Alarm when on battery : distinctive low battery alarm : configurable delays
Yes
Physical
Maximum Height
Maximum Width
Maximum Depth
Net Weight
Shipping Weight
Units per Pallet
683.00 mm
351.00 mm
452.00 mm
137.73 KG
155.91 KG
1.00
Color Beige
Environmental
Operating Environment
Operating Relative Humidity
Operating Elevation
Storage Temperature
Storage Relative Humidity
Storage Elevation
Audible noise at 1 meter from
surface of unit
Online Thermal Dissipation
0 - 40 °C
0%
0-3000 meters
-15 - 45 °C
0%
0-15000 meters
60.00 dBA
900.00 BTU/hr
Conformance
Regulatory Approvals
Standard Warranty
CE,CSA,FCC Part 15 Class A,UL 1778
2 years repair or replace,optional on-site warranties available,optional extended
warranties available
**The time to recharge to 90% of full battery capacity following a discharge to shutdown using a load rated for 1/2 the full
load rating of the UPS.
8.0 Storing the UPS
8.1 Storage Conditions
The UPS should be covered and stored in a cool dry location. The UPS should be stored with the Battery Packs in a
fully charged state. That is, the reported battery capacity should be at 100% before the UPS is switched off for storage.
Disconnect the Battery Packs from the UPS and from each other (where applicable). Store the Battery Packs in an
upright position.
8.2 Extended Storage
To achieve expected run time following extended storage, the UPS should be allowed to refresh the Battery Packs every
6 months in environments where the ambient temperature is -15°C to +30°C (5°F to 86°F). For extended storage in
environments where the ambient temperature is +30°C to +45°C (86°F to 113°F), the UPS should be allowed to refresh
the Battery Packs every 3 months.
9.0 Specifications
Note: Where specification ratings differ, values for the UPS configured for 240 Vac operation are given in brackets [ ].
9.1 Input
Nominal input voltage: single phase 208 Vac [240 Vac].
Nominal input frequency: 60 Hz.
On-line efficiency @ full load: > 92%, > 93% with fully charged batteries for the 3000VA and
5000VA models, respectively.
Input circuit breaker: 20 Amp, 30 Amp; for the 3000VA and 5000VA models, respectively.
Input connector: NEMA L6-30P (250V/30A).
9.2 Transfer Characteristics
Frequency limits for on-line operation: 60 Hz, ±5%.
Input voltage limits for on-line operation: -25% to +15% of the nominal input voltage.
Transfer to/from on-battery: 0 ms typical with computer loads, 1.5 ms maximum. Transfer occurs
synchronous with the utility voltage phase.
Transfer to/from bypass: Transfers to and from bypass occur synchronously with the utility voltage
phase. Transfers both to and from bypass mode occur in 0 mS typically.
9.3 Output Characteristics
Maximum load: *****************************;****************************
[5000VA,*********************]forthe3000VAand5000VAmodels,respectively.
Nominal output voltages: 208 Vac / 120 Vac [240 Vac / 120 Vac].
On-line voltage regulation: ±5%. When "Auto" or "Low" utility failure sensitivity is selected by the
user, the output voltage regulation may become relaxed to +5%, -12%.
On-line frequency regulation: 60 Hz, ±5% (synchronized to the utility).
On-battery output voltage regulation: ±5%.
On-battery output frequency regulation: 60 Hz, ±0.1 Hz unless synchronized to utility frequency
during utility brownout.
On-battery output voltage total harmonic distortion: < 5%.
Protection: overcurrent and short circuit protected, latching shutdown upon overload.
Output connections: (6) NEMA 5-15R receptacles, (1) NEMA L14-30R receptacle, and (2) NEMA
L6-30R receptacles.
9.4 Noise and Surge Isolation
Isolation: galvanic isolation, output neutral bonded to ground.
Normal mode EMI/RFI noise attenuation: 40 to 60 dB over 100 kHz to 30 MHz range.
Common mode EMI/RFI noise attenuation: 40 to 60 dB over 100 kHz to 30 MHz range.
Normal mode let-through: < 1% of applied ANSI C62.41 Category A or B ±6 kV test.
Common mode let-through: < 2% of applied ANSI C62.41 Category A or B ±6 kV test.
9.5 Battery Pack
Battery type: spill proof, maintenance free sealed lead-acid.
Nominal battery pack voltage: 48 Vdc.
Typical battery life: 3 to 6 years (depends upon number of discharge cycles and normal ambient
temperature).
Recharge time: see table in section 9.9.
Maximum number of Battery Packs: limited only by desired recharge time.
9.6 Environment
Operating temperature: 0°C to 40°C (32°F to 104°F).
Storage temperature: -15°C to 45°C (5°F to 113°F).
Operating and storage relative humidity: 0 to 95%, non-condensing.
Operating elevation: 0 to 3,000 m (10,000 ft).
Storage elevation: 0 to 15,000 m (50,000 ft).
Electromagnetic immunity: IEC 801-2, 801-3, 801-4, 801-5; severity level III or IV.
Audible noise: < 55 dBA at 1 m (3 ft).
9.7 Physical
UPS dimensions (EU and IU mated): 17.8" H x 13.8" W x 17.8" D (45.2 x 35.1 x 45.2 cm).
Battery pack dimensions: 9.1" H x 6.9" W x 17.8" D (23.1 x 17.5 x 45.2 cm).
UPS weight (EU and IU mated): 145 lb (65.8 kg), 176 lb (79.8 kg) for the 3000VA and 5000VA
models, respectively.
Electronics Unit (EU) weight: 40 lb (18.1 kg), 45 lb (20.4 kg) for the 3000VA and 5000VA models,
respectively. Add 8 lbs (3.6 kg) for shipping independent of IU.
Battery pack weight: 64 lbs (29.0 kg). Add 5 lbs (2.3 kg) for shipping independent of UPS.
Total shipping weight - 3000VA model: 244 lb (110.7 kg). Includes weight of packaging, mated EU
and IU, and one (1) Battery Pack.
Total shipping weight - 5000VA model: 344 lb (156.0 kg). Includes weight of packaging, mated EU
and IU, and two (2) Battery Packs.
Color: beige.
9.8 Approvals
Safety approvals: UL per 1778, CSA per C22.2.
EMC verification: FCC, CDC Class A verified.
9.9 Typical On-Battery Run Times
Typical On-Battery Run Time Versus Load, 3000 VA Matrix-UPS with SmartCells, in Hours
Number of SmartCells
Computer Load
(VA)
250
500
1000
1500
2000
2500
3000
1
3.07
1.46
0.57
0.33
0.22
0.17
0.13
2
7.20
3.52
1.46
0.83
0.57
0.46
0.36
3
11.56
5.80
2.46
1.46
0.99
0.78
0.62
4
15.93
8.24
3.52
2.11
1.46
1.18
0.92
5
20.29
10.69
4.58
2.81
1.93
1.59
1.25
6
24.65
13.13
5.80
3.52
2.46
1.99
1.59
7
29.02
15.57
7.02
4.23
2.99
2.45
1.92
8
33.38
18.01
8.24
4.99
3.52
2.90
2.30
Recharge Time, in Hours
1.22.82.73.84.9678.1
Calculations based on loads with a .75 power factor. Lower power factor loads will yield higher run times.
Run times are typical at 25° C (77° F).
Recharge times to 90% of rated capacity after discharge into 50% of rated load.
Typical On-Battery Run Time Versus Load, 3000 VA Matrix-UPS with SmartCell XR Battery Packs, in Hours
Number of SmartCell XR Battery Packs
Computer Load
(VA)
1000
1500
2000
2500
3000
1
3
1.8
1.2
0.9
0.75
2
6.75
4.3
3
2.4
1.8
3
10.75
6.9
5
4
3.25
4
14.75
9.5
7
5.6
4.7
5
18.75
12.1
9
7.2
6.15
6
22.75
14.7
11
8.8
7.6
7
26.75
17.3
13
10.4
9.05
8
30.75
19.9
15
12
10.5
Recharge Time, in Hours
3.88.112.516.921.325.730.134.5
Calculations based on loads with a .75 power factor. Lower power factor loads will yield higher run times.
Run times are typical at 25° C (77° F).
Recharge times to 90% of rated capacity after discharge into 50% of rated load.
Typical On-Battery Run Time Versus Load, 5000 VA Matrix-UPS with SmartCells, in Hours
Number of SmartCells
Computer Load
(VA)
500
1000
1500
2000
2500
3000
4000
5000
2
3.07
1.46
0.83
0.57
0.46
0.36
0.24
0.17
3
5.02
2.46
1.46
0.99
0.78
0.62
0.42
0.31
4
7.20
3.52
2.11
1.46
1.18
0.92
0.62
0.46
5
9.38
4.58
2.81
1.93
1.59
1.25
0.83
0.62
6
11.56
5.80
3.52
2.46
1.99
1.59
1.08
0.78
7
13.75
7.02
4.23
2.99
2.45
1.92
1.33
0.98
8
15.93
8.24
4.99
3.52
2.90
2.30
1.59
1.18
Recharge Time, in Hours
2.82.73.84.9678.1
The case of one SmartCell does not apply to 5000 VA Matrix-UPS.
Calculations based on loads with a .75 power factor. Lower power factor loads will yield higher run times.
Run times are typical at 25° C (77° F).
Recharge times to 90% of rated capacity after discharge into 50% of rated load.
Typical On-Battery Run Time Versus Load, 5000 VA Matrix-UPS with SmartCell XR Battery Packs, in Hours
Number of SmartCell XR Battery Packs
Computer Load
(VA)
1000
1500
2000
2500
3000
4000
5000
1
3
1.8
1.2
0.9
0.75
0.53
0.37
2
6.75
4.3
3
2.4
1.8
1.25
0.9
3
10.75
6.9
5
4
3.25
2.25
1.6
4
14.75
9.5
7
5.6
4.7
3.25
2.4
5
18.75
12.1
9
7.2
6.15
4.25
3.2
6
22.75
14.7
11
8.8
7.6
5.25
4
7
26.75
17.3
13
10.4
9.05
6.25
4.8
8
30.75
19.9
15
12
10.5
7.25
5.6
Recharge Time, in Hours
3.88.112.516.921.325.730.134.5
Calculations based on loads with a .75 power factor. Lower power factor loads will yield higher run times.
Run times are typical at 25° C (77° F).
Recharge times to 90% of rated capacity after discharge into 50% of rated load.
MX5000
2024年10月27日发(作者:机原)
MX5000
APC Matrix-UPS 5kVA 208V/240V In
120/208/240V Out
APC Matrix-UPS, 3750 Watts / 5000
VA,Input 208V / Output 120V, 208V, Interface
Port DB-9 RS-232, SmartSlot, Extended runtime
model
Includes
: CD with software, Smart UPS
signalling RS-232 cable, User Manual
Standard Lead Time
: Usually Ships within 2
Weeks
Matrix-UPS Features & Benefits
Availability
Automatic internal
bypass
Intelligent Battery
Management
Hot-swappable
batteries
Hot-swappable
Supplies utility power to the connected loads in the event of a UPS overload
condition or fault.
Maximizes battery performance, life, and reliability through intelligent,
precision charging.
Ensures clean, uninterrupted power to protected equipment while batteries
are being replaced
Ensures clean, uninterrupted power to protected equipment during Power
modules Module replacement.
Scalable runtime Allows additional run time to be quickly added as needed.
Automatic self-test Periodic battery self-test ensures early detection of a battery that needs to be
replaced.
Manageable external Reduces preventative maintenance service needs by monitoring the health
batteries and status of the external batteries and their expected runtime.
Battery modules Delivers higher availability through redundant batteries.
connected in parallel
Automatic restart of Automatically starts up the connected equipment upon the return of utility
loads after UPS power.
shutdown
Modular design Provides fast serviceability and reduced maintenance requirements via self-
diagnosing, field-replaceable modules.
Adaptability
Adjustable voltage-Maximizes useful battery life by widening the input voltage window or
transfer points tightening the output voltage regulation.
Plug-and-Play external Ensures clean, uninterrupted power to the loads when adding extra runtime to
batteries the UPS.
Field-replaceable Ensures compatibility with equipment that has different plug types.
power distribution
panel
Manageability
SmartSlot Customize UPS capabilities with management cards.
LCD display Alpha-Numeric Display which displays system parameters and alarms.
Serial Connectivity Provides management of the UPS via a serial port.
InfraStruXure Enables centralized management via the APC InfraStruXure® Manager.
Manager Compatible
Serviceability
User-replaceable Increases availability by allowing a trained user to perform upgrades and
batteries replacements of the batteries reducing Mean Time to Repair (MTTR)
Predictive failure Provides early-warning fault analysis ensuring proactive component
notification replacement.
User-replaceable Increases availability by allowing a trained user to perform upgrades and
batteries replacements of the batteries reducing Mean Time to Repair (MTTR)
User-replaceable Enables simple upgrades and replacements of the Power Modules.
power modules
Audible Alarms Actively let you know if the unit is on battery, if the battery is low or if there
is an overload condition.
Protection
Power conditioning
Boost and Trim
Automatic Voltage
Regulation (AVR)
Protects connected loads from surges, spikes, lightning, and other power
disturbances.
Gives higher application availability by correcting low and high voltage
conditions without using the battery.
Output
Output Power Capacity
Max Configurable Power
Nominal Output Voltage
Efficiency at Full Load
Output Voltage Distortion
Crest Factor
Waveform Type
Output Connections
3750 Watts / 5000 VA
3750 Watts / 5000 VA
120V,208V
93%
Less than 5% at full load
up to 5 : 1
Sine wave
(6) NEMA 5-15R
(1) NEMA L14-30R
(2) NEMA L6-30R
Bypass Internal Bypass (Automatic and Manual)
Output Frequency (sync to mains) 57 - 63 Hz for 60 Hz nominal
Input
Nominal Input Voltage
Input Frequency
Input Connections
Cord Length
Input voltage range for main
operations
Other Input Voltages
208V
60 Hz +/- 5 Hz
NEMA L6-30P
1.83 meters
156 - 252 (208) / 176 - 282 ( 240V)V
240
Batteries & Runtime
Battery Type
Typical recharge time
RBC™ Quantity
Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof
3.30 hour(s)
2
Replacement battery cartridge note The MX5000 ships with 2-SmartCell's. There is no RBC available for a standard
SmartCell. If a SmartCell-XR is being used,then an RBC14 may be purchased.
Typical Backup Time
at Half Load
Typical Backup Time
27.8 minutes (1875 Watts)
10.2 minutes (3750 Watts)
at Full Load
Runtime Chart
Extended Run Options
Matrix-UPS
APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out
Communications & Management
Interface Port(s)
Available SmartSlot™ Interface
Quantity
Control panel
Audible Alarm
Emergency Power Off (EPO)
DB-9 RS-232,SmartSlot
1
Multi-function LCD status and control console
Alarm when on battery : distinctive low battery alarm : configurable delays
Yes
Physical
Maximum Height
Maximum Width
Maximum Depth
Net Weight
Shipping Weight
Units per Pallet
683.00 mm
351.00 mm
452.00 mm
137.73 KG
155.91 KG
1.00
Color Beige
Environmental
Operating Environment
Operating Relative Humidity
Operating Elevation
Storage Temperature
Storage Relative Humidity
Storage Elevation
Audible noise at 1 meter from
surface of unit
Online Thermal Dissipation
0 - 40 °C
0%
0-3000 meters
-15 - 45 °C
0%
0-15000 meters
60.00 dBA
900.00 BTU/hr
Conformance
Regulatory Approvals
Standard Warranty
CE,CSA,FCC Part 15 Class A,UL 1778
2 years repair or replace,optional on-site warranties available,optional extended
warranties available
**The time to recharge to 90% of full battery capacity following a discharge to shutdown using a load rated for 1/2 the full
load rating of the UPS.
8.0 Storing the UPS
8.1 Storage Conditions
The UPS should be covered and stored in a cool dry location. The UPS should be stored with the Battery Packs in a
fully charged state. That is, the reported battery capacity should be at 100% before the UPS is switched off for storage.
Disconnect the Battery Packs from the UPS and from each other (where applicable). Store the Battery Packs in an
upright position.
8.2 Extended Storage
To achieve expected run time following extended storage, the UPS should be allowed to refresh the Battery Packs every
6 months in environments where the ambient temperature is -15°C to +30°C (5°F to 86°F). For extended storage in
environments where the ambient temperature is +30°C to +45°C (86°F to 113°F), the UPS should be allowed to refresh
the Battery Packs every 3 months.
9.0 Specifications
Note: Where specification ratings differ, values for the UPS configured for 240 Vac operation are given in brackets [ ].
9.1 Input
Nominal input voltage: single phase 208 Vac [240 Vac].
Nominal input frequency: 60 Hz.
On-line efficiency @ full load: > 92%, > 93% with fully charged batteries for the 3000VA and
5000VA models, respectively.
Input circuit breaker: 20 Amp, 30 Amp; for the 3000VA and 5000VA models, respectively.
Input connector: NEMA L6-30P (250V/30A).
9.2 Transfer Characteristics
Frequency limits for on-line operation: 60 Hz, ±5%.
Input voltage limits for on-line operation: -25% to +15% of the nominal input voltage.
Transfer to/from on-battery: 0 ms typical with computer loads, 1.5 ms maximum. Transfer occurs
synchronous with the utility voltage phase.
Transfer to/from bypass: Transfers to and from bypass occur synchronously with the utility voltage
phase. Transfers both to and from bypass mode occur in 0 mS typically.
9.3 Output Characteristics
Maximum load: *****************************;****************************
[5000VA,*********************]forthe3000VAand5000VAmodels,respectively.
Nominal output voltages: 208 Vac / 120 Vac [240 Vac / 120 Vac].
On-line voltage regulation: ±5%. When "Auto" or "Low" utility failure sensitivity is selected by the
user, the output voltage regulation may become relaxed to +5%, -12%.
On-line frequency regulation: 60 Hz, ±5% (synchronized to the utility).
On-battery output voltage regulation: ±5%.
On-battery output frequency regulation: 60 Hz, ±0.1 Hz unless synchronized to utility frequency
during utility brownout.
On-battery output voltage total harmonic distortion: < 5%.
Protection: overcurrent and short circuit protected, latching shutdown upon overload.
Output connections: (6) NEMA 5-15R receptacles, (1) NEMA L14-30R receptacle, and (2) NEMA
L6-30R receptacles.
9.4 Noise and Surge Isolation
Isolation: galvanic isolation, output neutral bonded to ground.
Normal mode EMI/RFI noise attenuation: 40 to 60 dB over 100 kHz to 30 MHz range.
Common mode EMI/RFI noise attenuation: 40 to 60 dB over 100 kHz to 30 MHz range.
Normal mode let-through: < 1% of applied ANSI C62.41 Category A or B ±6 kV test.
Common mode let-through: < 2% of applied ANSI C62.41 Category A or B ±6 kV test.
9.5 Battery Pack
Battery type: spill proof, maintenance free sealed lead-acid.
Nominal battery pack voltage: 48 Vdc.
Typical battery life: 3 to 6 years (depends upon number of discharge cycles and normal ambient
temperature).
Recharge time: see table in section 9.9.
Maximum number of Battery Packs: limited only by desired recharge time.
9.6 Environment
Operating temperature: 0°C to 40°C (32°F to 104°F).
Storage temperature: -15°C to 45°C (5°F to 113°F).
Operating and storage relative humidity: 0 to 95%, non-condensing.
Operating elevation: 0 to 3,000 m (10,000 ft).
Storage elevation: 0 to 15,000 m (50,000 ft).
Electromagnetic immunity: IEC 801-2, 801-3, 801-4, 801-5; severity level III or IV.
Audible noise: < 55 dBA at 1 m (3 ft).
9.7 Physical
UPS dimensions (EU and IU mated): 17.8" H x 13.8" W x 17.8" D (45.2 x 35.1 x 45.2 cm).
Battery pack dimensions: 9.1" H x 6.9" W x 17.8" D (23.1 x 17.5 x 45.2 cm).
UPS weight (EU and IU mated): 145 lb (65.8 kg), 176 lb (79.8 kg) for the 3000VA and 5000VA
models, respectively.
Electronics Unit (EU) weight: 40 lb (18.1 kg), 45 lb (20.4 kg) for the 3000VA and 5000VA models,
respectively. Add 8 lbs (3.6 kg) for shipping independent of IU.
Battery pack weight: 64 lbs (29.0 kg). Add 5 lbs (2.3 kg) for shipping independent of UPS.
Total shipping weight - 3000VA model: 244 lb (110.7 kg). Includes weight of packaging, mated EU
and IU, and one (1) Battery Pack.
Total shipping weight - 5000VA model: 344 lb (156.0 kg). Includes weight of packaging, mated EU
and IU, and two (2) Battery Packs.
Color: beige.
9.8 Approvals
Safety approvals: UL per 1778, CSA per C22.2.
EMC verification: FCC, CDC Class A verified.
9.9 Typical On-Battery Run Times
Typical On-Battery Run Time Versus Load, 3000 VA Matrix-UPS with SmartCells, in Hours
Number of SmartCells
Computer Load
(VA)
250
500
1000
1500
2000
2500
3000
1
3.07
1.46
0.57
0.33
0.22
0.17
0.13
2
7.20
3.52
1.46
0.83
0.57
0.46
0.36
3
11.56
5.80
2.46
1.46
0.99
0.78
0.62
4
15.93
8.24
3.52
2.11
1.46
1.18
0.92
5
20.29
10.69
4.58
2.81
1.93
1.59
1.25
6
24.65
13.13
5.80
3.52
2.46
1.99
1.59
7
29.02
15.57
7.02
4.23
2.99
2.45
1.92
8
33.38
18.01
8.24
4.99
3.52
2.90
2.30
Recharge Time, in Hours
1.22.82.73.84.9678.1
Calculations based on loads with a .75 power factor. Lower power factor loads will yield higher run times.
Run times are typical at 25° C (77° F).
Recharge times to 90% of rated capacity after discharge into 50% of rated load.
Typical On-Battery Run Time Versus Load, 3000 VA Matrix-UPS with SmartCell XR Battery Packs, in Hours
Number of SmartCell XR Battery Packs
Computer Load
(VA)
1000
1500
2000
2500
3000
1
3
1.8
1.2
0.9
0.75
2
6.75
4.3
3
2.4
1.8
3
10.75
6.9
5
4
3.25
4
14.75
9.5
7
5.6
4.7
5
18.75
12.1
9
7.2
6.15
6
22.75
14.7
11
8.8
7.6
7
26.75
17.3
13
10.4
9.05
8
30.75
19.9
15
12
10.5
Recharge Time, in Hours
3.88.112.516.921.325.730.134.5
Calculations based on loads with a .75 power factor. Lower power factor loads will yield higher run times.
Run times are typical at 25° C (77° F).
Recharge times to 90% of rated capacity after discharge into 50% of rated load.
Typical On-Battery Run Time Versus Load, 5000 VA Matrix-UPS with SmartCells, in Hours
Number of SmartCells
Computer Load
(VA)
500
1000
1500
2000
2500
3000
4000
5000
2
3.07
1.46
0.83
0.57
0.46
0.36
0.24
0.17
3
5.02
2.46
1.46
0.99
0.78
0.62
0.42
0.31
4
7.20
3.52
2.11
1.46
1.18
0.92
0.62
0.46
5
9.38
4.58
2.81
1.93
1.59
1.25
0.83
0.62
6
11.56
5.80
3.52
2.46
1.99
1.59
1.08
0.78
7
13.75
7.02
4.23
2.99
2.45
1.92
1.33
0.98
8
15.93
8.24
4.99
3.52
2.90
2.30
1.59
1.18
Recharge Time, in Hours
2.82.73.84.9678.1
The case of one SmartCell does not apply to 5000 VA Matrix-UPS.
Calculations based on loads with a .75 power factor. Lower power factor loads will yield higher run times.
Run times are typical at 25° C (77° F).
Recharge times to 90% of rated capacity after discharge into 50% of rated load.
Typical On-Battery Run Time Versus Load, 5000 VA Matrix-UPS with SmartCell XR Battery Packs, in Hours
Number of SmartCell XR Battery Packs
Computer Load
(VA)
1000
1500
2000
2500
3000
4000
5000
1
3
1.8
1.2
0.9
0.75
0.53
0.37
2
6.75
4.3
3
2.4
1.8
1.25
0.9
3
10.75
6.9
5
4
3.25
2.25
1.6
4
14.75
9.5
7
5.6
4.7
3.25
2.4
5
18.75
12.1
9
7.2
6.15
4.25
3.2
6
22.75
14.7
11
8.8
7.6
5.25
4
7
26.75
17.3
13
10.4
9.05
6.25
4.8
8
30.75
19.9
15
12
10.5
7.25
5.6
Recharge Time, in Hours
3.88.112.516.921.325.730.134.5
Calculations based on loads with a .75 power factor. Lower power factor loads will yield higher run times.
Run times are typical at 25° C (77° F).
Recharge times to 90% of rated capacity after discharge into 50% of rated load.
MX5000