Safety and General Information
Inspect the package contents upon receipt. Notify the
carrier and dealer if there is any damage.
Read the Safety Guide supplied with this unit before
installing the UPS.
• This unit is designed for low power devices less than 75 Watts. When the UPS is
on battery, the unit will shut down automatically to protect itself once the load on
the UPS is greater than 75Watts.
• This UPS is intended for indoor use only.
• Do not operate this UPS in direct sunlight, in contact with fluids, or where there is
excessive dust or humidity.
• Be sure the air vents on the UPS are not blocked. Allow adequate space for proper
ventilation.
• The battery typically lasts for three to five years. Environmental factors impact
battery life. Elevated ambient temperatures, poor quality AC power, and frequent
short duration discharges will shorten battery life.
• Connect the UPS power cable directly to a wall outlet. Do not use surge protectors
or extension cords.
Specifications
Input
Voltage120 Vac Nominal
Frequency50/60 Hz + 3
Brownout Transfers92 Vac Typical
Over-voltage Transfer139 Vac Typical
Output
UPS Capacity 125 VA, 75 W
(3 battery backup outlets)
Total Amperage (all outlets)1.04 A (including UPS output)
Voltage - On Battery115 Vac ± 8%
Frequency - On Battery50/60 Hz + 1
Transfer Time6 ms Typical, 10 ms maximum
Protection
AC Surge ProtectionFull time, 90 Joules
and
Filtering
EMI/RFI FilterFull time
AC InputResettable circuit breaker
Battery
TypeSealed, maintenance-free, lead acid
RBC153
Average Life3 - 5 years depending on the number of
discharge cycles and environmental
temperature
Physical
Net Weight5.51 lb (2.5 kg)
Dimensions 8.9 in x 4.1 in x 5.2 in
Length x Width x Height22.5 cm x 10.5 cm x 13.2 cm
Operating Temperature32º F to 104º F (0º C to 40º C)
Storage Temperature5º F to 113º F (–15º C to 45º C)
Operating Relative Humidity0 to 95% non-condensing humidity
Operating Elevation0 to 10,000 ft (0 to 3000 m)
Connect the Battery
The Back-UPS is shipped with one battery cable disconnected.
a
5
7
3
u
b
u
3
7
9
a
b
Remove the “Stop! Connect the
Press the battery compartment cover
Battery” label that covers the outlets.
release tabs located on the rear side of the
unit. Slide the battery cover off.
a
7
8
6
a
u
3
3
7
b
u
b
Connect the battery cable securely to
Reinstall the battery compartment cover.
the battery terminal. It is normal for small
Be sure that the release tab locks into place.
sparks to be seen when the battery cable is
connected to the battery terminal.
Connect Equipment
bu377a
Battery Backup Outlets
Battery backup outlets provide protection to connected equipment when the
Back-UPS is turned on and connected to AC power.
Battery backup outlets receive power from the Back-UPS for a limited period of time
when a power outage, or brownout condition occurs.
Battery backup outlets provide protection from power surges or spikes.
Connect a broadband modem and wireless router to the outlets. Voice over IP (VOIP)
phones (if applicable) should also be plugged into battery backup outlets.
To maximize runtime in the event of a power outage only connect networking
equipment to battery backup outlets.
This UPS is designed to sustain low power devices for extended periods of time.
When the UPS is on battery, the unit will shut down automatically if the load on the
UPS exceeds 75Watts. Low power devices include modems, routers, USB chargers
(5W and 10W), VOIP and cordless phones.
Turn On the Back-UPS
Press the P
OWER
ON button located on the top of the Back-UPS. The Power On/
Replace Battery LED will illuminate and a single short beep will be audible to
indicate that the Back-UPS is providing protection for connected equipment.
The Back-UPS battery charges fully during the first 16 hours while connected to AC
power. The Back-UPS battery will charge while the Back-UPS is switched on or off
and is connected to AC power. Do not expect full battery run capability during the
initial charge time.
Status Indicators
Status
Power Button Audible Audible Indicator
LEDIndicator OnTerminates
Power On
The LED NoneN/A
The Back-UPS is
illuminates green.
supplying AC power to
connected equipment.
On BatteryThe LED
Back-UPS
Beeping stops at the
Back-UPS supplying illuminates green.
beeps for 2
end of the first two
battery power to battery The LED flashes
seconds
seconds. A constant
backup at the end of
when
beep at the initial
every 2 seconds.
entering
two seconds
battery
indicates the Back-
mode.
UPS has entered the
battery mode.
Low Battery warningThe LED The Back-Beeping stops when
The Back-UPS is illuminates green UPS emits AC power is
supplying battery power to and flashes in rapid restored or the Back-
the battery backup outlets rapid g, UPS is turned off.
and the battery is near a every
total discharge state.1/2 second.
Replace BatteryThe LED Constant Back-UPS is turned
•The battery is alternately toneoff.
nates green-
•The battery needs to be red.
Constant
charged, or replaced.
tone
Overload Shutdown
NoneConstant Back-UPS is turned
While on battery power an
toneoff.
overload condition has
occurred in one or more of
the battery backup outlets
while the Back-UPS is
operating on battery
power.
Sleep Mode
NoneThe Back-The beeping stops
While on battery power
UPS beeps when:
the battery is completely
once every •AC power is
discharged. The
four ed
Back-UPS will “awaken”
•If AC power is not
once AC power is
restored within 32
restored.
seconds
•The Back-UPS is
turned off
Wall Mount Installation
•Horizontal installation, use 2 screws 3-15/16” (100 mm) apart.
•Allow 5/16” (8 mm), of the screw to protrude from the wall.
3 in.
100 mm
Wall-mounting Template
bu380a
Voltage Sensitivity Adjustment (optional)
The Back-UPS detects and reacts to line voltage distortions by transferring to battery
backup power to protect connected equipment. In situations where either the Back-UPS
or the connected equipment is too sensitive for the input voltage level it is necessary to
adjust the transfer voltage.
t the Back-UPS to a wall outlet. The Back-UPS will be in Standby mode,
no indicators will be illuminated.
and hold the ON/OFF button for 10 seconds. The OnLine LED will
illuminate alternately green-red, to indicate that the Back-UPS is in Program
mode.
Power On/Replace Battery LED will flash either green, amber, or red to
indicate the current sensitivity level. Refer to the table for an explanation of the
transfer voltage sensitivity levels.
select LOW sensitivity, press and hold the ON/OFF button until the LED
flashes green.
select MEDIUM sensitivity, press and hold the ON/OFF button until the LED
flashes red.
select HIGH sensitivity, press and hold the ON/OFF button until the LED
flashes amber.
exit Program mode wait five seconds and all LED indicators will extinguish.
Program mode is no longer active.
LED
Flashes
Green
Sensitivity
Setting
LOW
Input Voltage Range
(AC Operation)
88 Vac to 142 Vac
Recommended Use
Use this setting with equipment that is
less sensitive to fluctuations in voltage
or waveform distortions.
Factory default setting. Use this setting
under normal conditions.
Use this setting when connected
equipment is sensitive to voltage and
waveform fluctuations.
Replace Battery
Deliver the used battery to a recycling facility.
Replace the used battery with an APC by Schneider Electric approved
battery. Replacement batteries can be ordered through the APC by
Schneider Electric Web site, . Battery replacement part for
Back-UPS BGE70 is APCRBC153.
Service
If the unit requires service, do not return it to the dealer. Follow these steps:
the Troubleshooting section of the manual to eliminate common problems.
the problem persists, contact Schneider Electric IT (SEIT) Customer Support
through the APC by Schneider Electric Web site, .
the model number and serial number and the date of purchase. The model
and serial numbers are located on the rear panel of the unit and are available
through the LCD display on select models.
SEIT Customer Support and a technician will attempt to solve the
problem over the phone. If this is not possible, the technician will issue a
Returned Material Authorization Number (RMA#).
the unit is under warranty, the repairs are free.
e procedures and returns may vary internationally. Refer to the APC by
Schneider Electric Web site for country specific instructions.
the unit in the original packaging whenever possible to avoid damage in
transit. Never use foam beads for packaging. Damage sustained in transit is not
covered under warranty.
DISCONNECT THE UPS BATTERIES before shipping. The United
States Department of Transportation (DOT), and the International Air
Transport Association (IATA) regulations require that UPS batteries be
disconnected before shipping. The internal batteries may remain in the UPS.
the RMA# provided by Customer Support on the outside of the package.
the unit by insured, pre-paid carrier to the address provided by Customer
Support
Red
Amber
MEDIUM
HIGH
92 Vac to 139 Vac
96 Vac to 136 Vac
Troubleshooting
Problem and Possible Cause
The Back-UPS will not turn on
The Back-UPS has not been turned
on.
The Back-UPS is not connected to
AC power, there is no AC power
available at the wall outlet, or the AC
power is experiencing a brownout or
over voltage condition.
The battery is not connected.
Press the P
OWER
ON
button.
Make sure the power cord is securely connected to
the wall outlet, and that there is AC power
available at the wall applicable,
check that the wall outlet is switched on.
Connect the battery. Refer to “Connect the
Battery” on page1 of this manual.
In the event that the Back-UPS receives no AC
power and the battery is connected, a cold-start can
be initiated. Press and hold the Power On button
until the Back-UPS emits two beeps.
Solution
Warranty
The standard warranty is three (3) years from the date of purchase. Schneider Electric IT
(SEIT) standard procedure is to replace the original unit with a factory reconditioned
unit. Customers who must have the original unit back due to the assignment of asset tags
and set depreciation schedules must declare such a need at first contact with an SEIT
Technical Support representative. SEIT will ship the replacement unit once the defective
unit has been received by the repair department, or cross ship upon the receipt of a valid
credit card number. The customer pays for shipping the unit to SEIT. SEIT pays ground
freight transportation costs to ship the replacement unit to the customer.
APC by Schneider Electric IT Customer Support
Worldwide
For country specific customer support, go to the APC by Schneider Electric Web site,
.
The Back-UPS is on, the Replace Battery LED flashes and the unit emits a constant
tone
The battery is disconnected.
Connected equipment loses power
A Back-UPS overload condition has
occurred.
The Back-UPS battery is completely
discharged.
Remove all nonessential equipment connected to
the outlets. One at a time reconnect equipment to
the Back-UPS.
Connect the Back-UPS to AC power and allow the
battery to recharge for eight hours.
Refer to the “Connect the Battery” on page1.
EMC Compliance
This device complies with part 15 of the FCC rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) This device
must accept any interference received, including interference that may cause undesired
operation.
Connected equipment does not accept
The output waveform is intended for computers
the step-approximated sine waveform
and peripheral devices. It is not intended for use
with motor driven equipment.
from the Back-UPS.
The Back-UPS may require t Schneider Electric IT (SEIT) Technical
Support for more in depth troubleshooting.
This UPS is certified to comply with California Battery Charger System
regulations. For more information go to
/site/recycle//energy-efficiency/cec-battery-charger/
The Power On LED is illuminated and the Back-UPS beeps 4 times every 30 seconds
The Back-UPS is operating on battery The Back-UPS is operating normally on battery
. At this point the user should save all open
files, and shutdown the computer. When AC power
is restored the battery will recharge.
The Power On LED flashes once every second while the Back-UPS beeps once every
second
The Back-UPS battery has
approximately two minutes of
remaining runtime.
The Back-UPS battery is near a total discharge
state. At this point the user should save all open
files, and shutdown the computer. When AC power
is restored the battery will recharge.
Leave the Back-UPS connected to AC power for
16 hours while the battery charges to full capacity.
As a battery ages, the runtime capability decreases.
Contact APC by Schneider Electric at the Web site
, to order replacement batteries.
Connect the broadband modem into one of the
Battery Backup + Surge Protection outlets.
The Back-UPS has an inadequate battery runtime
The battery is not fully charged.
The battery is near the end of useful
life and should be replaced.
The connection from the Back-UPS to the internet is lost during a power outage
The modem has lost power.
© 2013 APC by Schneider Electric. APC, the APC logo, and Back-UPS are owned by Schneider Electric Industries S.A.S., or their affiliated companies. All other trademarks are
property of their respective owners.
EN 990-5285
12/2013
2024年6月14日发(作者:南门如冬)
Inventory
b
u
3
7
4
a
Safety and General Information
Inspect the package contents upon receipt. Notify the
carrier and dealer if there is any damage.
Read the Safety Guide supplied with this unit before
installing the UPS.
• This unit is designed for low power devices less than 75 Watts. When the UPS is
on battery, the unit will shut down automatically to protect itself once the load on
the UPS is greater than 75Watts.
• This UPS is intended for indoor use only.
• Do not operate this UPS in direct sunlight, in contact with fluids, or where there is
excessive dust or humidity.
• Be sure the air vents on the UPS are not blocked. Allow adequate space for proper
ventilation.
• The battery typically lasts for three to five years. Environmental factors impact
battery life. Elevated ambient temperatures, poor quality AC power, and frequent
short duration discharges will shorten battery life.
• Connect the UPS power cable directly to a wall outlet. Do not use surge protectors
or extension cords.
Specifications
Input
Voltage120 Vac Nominal
Frequency50/60 Hz + 3
Brownout Transfers92 Vac Typical
Over-voltage Transfer139 Vac Typical
Output
UPS Capacity 125 VA, 75 W
(3 battery backup outlets)
Total Amperage (all outlets)1.04 A (including UPS output)
Voltage - On Battery115 Vac ± 8%
Frequency - On Battery50/60 Hz + 1
Transfer Time6 ms Typical, 10 ms maximum
Protection
AC Surge ProtectionFull time, 90 Joules
and
Filtering
EMI/RFI FilterFull time
AC InputResettable circuit breaker
Battery
TypeSealed, maintenance-free, lead acid
RBC153
Average Life3 - 5 years depending on the number of
discharge cycles and environmental
temperature
Physical
Net Weight5.51 lb (2.5 kg)
Dimensions 8.9 in x 4.1 in x 5.2 in
Length x Width x Height22.5 cm x 10.5 cm x 13.2 cm
Operating Temperature32º F to 104º F (0º C to 40º C)
Storage Temperature5º F to 113º F (–15º C to 45º C)
Operating Relative Humidity0 to 95% non-condensing humidity
Operating Elevation0 to 10,000 ft (0 to 3000 m)
Connect the Battery
The Back-UPS is shipped with one battery cable disconnected.
a
5
7
3
u
b
u
3
7
9
a
b
Remove the “Stop! Connect the
Press the battery compartment cover
Battery” label that covers the outlets.
release tabs located on the rear side of the
unit. Slide the battery cover off.
a
7
8
6
a
u
3
3
7
b
u
b
Connect the battery cable securely to
Reinstall the battery compartment cover.
the battery terminal. It is normal for small
Be sure that the release tab locks into place.
sparks to be seen when the battery cable is
connected to the battery terminal.
Connect Equipment
bu377a
Battery Backup Outlets
Battery backup outlets provide protection to connected equipment when the
Back-UPS is turned on and connected to AC power.
Battery backup outlets receive power from the Back-UPS for a limited period of time
when a power outage, or brownout condition occurs.
Battery backup outlets provide protection from power surges or spikes.
Connect a broadband modem and wireless router to the outlets. Voice over IP (VOIP)
phones (if applicable) should also be plugged into battery backup outlets.
To maximize runtime in the event of a power outage only connect networking
equipment to battery backup outlets.
This UPS is designed to sustain low power devices for extended periods of time.
When the UPS is on battery, the unit will shut down automatically if the load on the
UPS exceeds 75Watts. Low power devices include modems, routers, USB chargers
(5W and 10W), VOIP and cordless phones.
Turn On the Back-UPS
Press the P
OWER
ON button located on the top of the Back-UPS. The Power On/
Replace Battery LED will illuminate and a single short beep will be audible to
indicate that the Back-UPS is providing protection for connected equipment.
The Back-UPS battery charges fully during the first 16 hours while connected to AC
power. The Back-UPS battery will charge while the Back-UPS is switched on or off
and is connected to AC power. Do not expect full battery run capability during the
initial charge time.
Status Indicators
Status
Power Button Audible Audible Indicator
LEDIndicator OnTerminates
Power On
The LED NoneN/A
The Back-UPS is
illuminates green.
supplying AC power to
connected equipment.
On BatteryThe LED
Back-UPS
Beeping stops at the
Back-UPS supplying illuminates green.
beeps for 2
end of the first two
battery power to battery The LED flashes
seconds
seconds. A constant
backup at the end of
when
beep at the initial
every 2 seconds.
entering
two seconds
battery
indicates the Back-
mode.
UPS has entered the
battery mode.
Low Battery warningThe LED The Back-Beeping stops when
The Back-UPS is illuminates green UPS emits AC power is
supplying battery power to and flashes in rapid restored or the Back-
the battery backup outlets rapid g, UPS is turned off.
and the battery is near a every
total discharge state.1/2 second.
Replace BatteryThe LED Constant Back-UPS is turned
•The battery is alternately toneoff.
nates green-
•The battery needs to be red.
Constant
charged, or replaced.
tone
Overload Shutdown
NoneConstant Back-UPS is turned
While on battery power an
toneoff.
overload condition has
occurred in one or more of
the battery backup outlets
while the Back-UPS is
operating on battery
power.
Sleep Mode
NoneThe Back-The beeping stops
While on battery power
UPS beeps when:
the battery is completely
once every •AC power is
discharged. The
four ed
Back-UPS will “awaken”
•If AC power is not
once AC power is
restored within 32
restored.
seconds
•The Back-UPS is
turned off
Wall Mount Installation
•Horizontal installation, use 2 screws 3-15/16” (100 mm) apart.
•Allow 5/16” (8 mm), of the screw to protrude from the wall.
3 in.
100 mm
Wall-mounting Template
bu380a
Voltage Sensitivity Adjustment (optional)
The Back-UPS detects and reacts to line voltage distortions by transferring to battery
backup power to protect connected equipment. In situations where either the Back-UPS
or the connected equipment is too sensitive for the input voltage level it is necessary to
adjust the transfer voltage.
t the Back-UPS to a wall outlet. The Back-UPS will be in Standby mode,
no indicators will be illuminated.
and hold the ON/OFF button for 10 seconds. The OnLine LED will
illuminate alternately green-red, to indicate that the Back-UPS is in Program
mode.
Power On/Replace Battery LED will flash either green, amber, or red to
indicate the current sensitivity level. Refer to the table for an explanation of the
transfer voltage sensitivity levels.
select LOW sensitivity, press and hold the ON/OFF button until the LED
flashes green.
select MEDIUM sensitivity, press and hold the ON/OFF button until the LED
flashes red.
select HIGH sensitivity, press and hold the ON/OFF button until the LED
flashes amber.
exit Program mode wait five seconds and all LED indicators will extinguish.
Program mode is no longer active.
LED
Flashes
Green
Sensitivity
Setting
LOW
Input Voltage Range
(AC Operation)
88 Vac to 142 Vac
Recommended Use
Use this setting with equipment that is
less sensitive to fluctuations in voltage
or waveform distortions.
Factory default setting. Use this setting
under normal conditions.
Use this setting when connected
equipment is sensitive to voltage and
waveform fluctuations.
Replace Battery
Deliver the used battery to a recycling facility.
Replace the used battery with an APC by Schneider Electric approved
battery. Replacement batteries can be ordered through the APC by
Schneider Electric Web site, . Battery replacement part for
Back-UPS BGE70 is APCRBC153.
Service
If the unit requires service, do not return it to the dealer. Follow these steps:
the Troubleshooting section of the manual to eliminate common problems.
the problem persists, contact Schneider Electric IT (SEIT) Customer Support
through the APC by Schneider Electric Web site, .
the model number and serial number and the date of purchase. The model
and serial numbers are located on the rear panel of the unit and are available
through the LCD display on select models.
SEIT Customer Support and a technician will attempt to solve the
problem over the phone. If this is not possible, the technician will issue a
Returned Material Authorization Number (RMA#).
the unit is under warranty, the repairs are free.
e procedures and returns may vary internationally. Refer to the APC by
Schneider Electric Web site for country specific instructions.
the unit in the original packaging whenever possible to avoid damage in
transit. Never use foam beads for packaging. Damage sustained in transit is not
covered under warranty.
DISCONNECT THE UPS BATTERIES before shipping. The United
States Department of Transportation (DOT), and the International Air
Transport Association (IATA) regulations require that UPS batteries be
disconnected before shipping. The internal batteries may remain in the UPS.
the RMA# provided by Customer Support on the outside of the package.
the unit by insured, pre-paid carrier to the address provided by Customer
Support
Red
Amber
MEDIUM
HIGH
92 Vac to 139 Vac
96 Vac to 136 Vac
Troubleshooting
Problem and Possible Cause
The Back-UPS will not turn on
The Back-UPS has not been turned
on.
The Back-UPS is not connected to
AC power, there is no AC power
available at the wall outlet, or the AC
power is experiencing a brownout or
over voltage condition.
The battery is not connected.
Press the P
OWER
ON
button.
Make sure the power cord is securely connected to
the wall outlet, and that there is AC power
available at the wall applicable,
check that the wall outlet is switched on.
Connect the battery. Refer to “Connect the
Battery” on page1 of this manual.
In the event that the Back-UPS receives no AC
power and the battery is connected, a cold-start can
be initiated. Press and hold the Power On button
until the Back-UPS emits two beeps.
Solution
Warranty
The standard warranty is three (3) years from the date of purchase. Schneider Electric IT
(SEIT) standard procedure is to replace the original unit with a factory reconditioned
unit. Customers who must have the original unit back due to the assignment of asset tags
and set depreciation schedules must declare such a need at first contact with an SEIT
Technical Support representative. SEIT will ship the replacement unit once the defective
unit has been received by the repair department, or cross ship upon the receipt of a valid
credit card number. The customer pays for shipping the unit to SEIT. SEIT pays ground
freight transportation costs to ship the replacement unit to the customer.
APC by Schneider Electric IT Customer Support
Worldwide
For country specific customer support, go to the APC by Schneider Electric Web site,
.
The Back-UPS is on, the Replace Battery LED flashes and the unit emits a constant
tone
The battery is disconnected.
Connected equipment loses power
A Back-UPS overload condition has
occurred.
The Back-UPS battery is completely
discharged.
Remove all nonessential equipment connected to
the outlets. One at a time reconnect equipment to
the Back-UPS.
Connect the Back-UPS to AC power and allow the
battery to recharge for eight hours.
Refer to the “Connect the Battery” on page1.
EMC Compliance
This device complies with part 15 of the FCC rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) This device
must accept any interference received, including interference that may cause undesired
operation.
Connected equipment does not accept
The output waveform is intended for computers
the step-approximated sine waveform
and peripheral devices. It is not intended for use
with motor driven equipment.
from the Back-UPS.
The Back-UPS may require t Schneider Electric IT (SEIT) Technical
Support for more in depth troubleshooting.
This UPS is certified to comply with California Battery Charger System
regulations. For more information go to
/site/recycle//energy-efficiency/cec-battery-charger/
The Power On LED is illuminated and the Back-UPS beeps 4 times every 30 seconds
The Back-UPS is operating on battery The Back-UPS is operating normally on battery
. At this point the user should save all open
files, and shutdown the computer. When AC power
is restored the battery will recharge.
The Power On LED flashes once every second while the Back-UPS beeps once every
second
The Back-UPS battery has
approximately two minutes of
remaining runtime.
The Back-UPS battery is near a total discharge
state. At this point the user should save all open
files, and shutdown the computer. When AC power
is restored the battery will recharge.
Leave the Back-UPS connected to AC power for
16 hours while the battery charges to full capacity.
As a battery ages, the runtime capability decreases.
Contact APC by Schneider Electric at the Web site
, to order replacement batteries.
Connect the broadband modem into one of the
Battery Backup + Surge Protection outlets.
The Back-UPS has an inadequate battery runtime
The battery is not fully charged.
The battery is near the end of useful
life and should be replaced.
The connection from the Back-UPS to the internet is lost during a power outage
The modem has lost power.