2024年8月31日发(作者:晁骊燕)
Eaton 199200
Eaton Moeller® series PKZM0 Motor-protective circuit-breaker, 7.5
kW, 10 - 16 A, Feed-side screw terminals/output-side push-in
terminals, MSC
General specifications
Product NameCatalog Number
Eaton Moeller® series PKZM0 Motor-199200
protective circuit-breaker
EAN
4
Model CodeProduct Length/Depth
PKZM0-16-SPI3275 mm
Product HeightProduct Width
102 mm45 mm
Product WeightCertifications
0.319 kgVDE 0660
IEC/EN 60947
UL File No.: E36332
IEC/EN 60947-4-1
CSA File No.: 165628
UL Category Control No.: NLRV
UL
CSA-C22.2 No. 60947-4-1-14
CSA Class No.: 3211-05
CSA
UL 60947-4-1
CE
UL
CSA
Actuator type
Turn button
Features
Phase-failure sensitivity (according to IEC/EN 60947-4-1, VDE
0660 Part 102)
Functions
Phase failure sensitive
Motor protection
Number of poles
Three-pole
Lifespan, electrical
100,000 operations
Lifespan, mechanical
100,000 Operations
Mounting Method
DIN rail (top hat rail) mounting optional
Mounting position
Can be snapped on to IEC/EN 60715 top-hat rail with 7.5 or
15 mm height.
Operating frequency
40 Operations/h
Overvoltage category
III
Pollution degree
3
Product category
Motor protective circuit breaker
Protection
Finger and back-of-hand proof, Protection against direct contact
when actuated from front (EN 50274)
Rated impulse withstand voltage (Uimp)
6000 V AC
Shock resistance
25 g, Mechanical, according to IEC/EN 60068-2-27, Half-
sinusoidal shock 10 ms
Suitable for
Also motors with efficiency class IE3
Branch circuit: Manual type E if used with terminal, or suitable for
group installations, (UL/CSA)
Temperature compensation
-5 - 40 °C to IEC/EN 60947, VDE 0660
-25 - 55 °C, Operating range
≤ 0.25 %/K, residual error for T > 40°
Used with
Motor starter combinations
Altitude
Max. 2000 m
Ambient operating temperature - min
-25 °C
Ambient operating temperature - max
55 °C
Ambient operating temperature (enclosed) - min
-25 °C
Ambient operating temperature (enclosed) - max
40 °C
Ambient storage temperature - min
-40 °C
Ambient storage temperature - max
80 °C
Climatic proofing
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Short-circuit current rating (type E)
65 kA, 240 V, SCCR (UL/CSA) with contactor DILM17
65 kA, 480 Y/277 V, SCCR (UL/CSA) with contactor DILM17
Short-circuit release
248 A, Irm, Setting range max.
± 20% tolerance, Trip blocks
Basic device fixed 15.5 x Iu, Trip Blocks
Terminal capacity (flexible)
1 x (1 - 6) mm²
Stripping length (main cable)
12 mm
Tightening torque
1.7 Nm, Screw terminals, Main cable
Rated frequency - min
50 Hz
Rated frequency - max
60 Hz
Rated operational current (Ie)
16 A
Rated operational power at AC-3, 220/230 V, 50 Hz
4 kW
Rated operational power at AC-3, 380/400 V, 50 Hz
7.5 kW
Rated operational voltage (Ue) - min
690 V
Rated operational voltage (Ue) - max
690 V
Rated uninterrupted current (Iu)
16 A
Assigned motor power at 115/120 V, 60 Hz, 1-phase
1 HP
Assigned motor power at 200/208 V, 60 Hz, 3-phase
3 HP
Assigned motor power at 230/240 V, 60 Hz, 1-phase
2 HP
Assigned motor power at 230/240 V, 60 Hz, 3-phase
5 HP
Assigned motor power at 460/480 V, 60 Hz, 3-phase
10 HP
Assigned motor power at 575/600 V, 60 Hz, 3-phase
10 HP
Number of auxiliary contacts (change-over contacts)
0
Number of auxiliary contacts (normally closed contacts)
0
Number of auxiliary contacts (normally open contacts)
0
Equipment heat dissipation, current-dependent Pvid
6.43 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
0 W
Static heat dissipation, non-current-dependent Pvs
0 W
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to
normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal
elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be
Connection
Screw terminals on feed side
Push-in terminals on output side
Overload release current setting - min
16 A
Overload release current setting - max
16 A
Tripping characteristic
Overload trigger: tripping class 10 A
Brochures
Save time and space thanks to the new link module PKZM0-XDM32ME
Motor Starters in System xStart - brochure
Catalogs
Product Range Catalog Switching and protecting motors
Switching and protecting motors - catalog
Declarations of conformity
Drawings
121X002
121X042
eCAD model
Installation instructions
IL122024ZU
Installation videos
WIN-WIN with push-in technology
evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be
evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be
evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be
evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be
evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise
calculation. Eaton will provide heat dissipation data for the
devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the
switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the
switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in
mCAD model
pkzm0_s32_
pkzm0_s32_
the instruction leaflet (IL) is observed.
Eaton Corporation plc
Eaton House
30 Pembroke Road
Dublin 4, Ireland
Eaton is a registered trademark.
All other trademarks are
© 2023 Eaton. All Rights property of their respective
Reserved. owners.
/socialmedia
2024年8月31日发(作者:晁骊燕)
Eaton 199200
Eaton Moeller® series PKZM0 Motor-protective circuit-breaker, 7.5
kW, 10 - 16 A, Feed-side screw terminals/output-side push-in
terminals, MSC
General specifications
Product NameCatalog Number
Eaton Moeller® series PKZM0 Motor-199200
protective circuit-breaker
EAN
4
Model CodeProduct Length/Depth
PKZM0-16-SPI3275 mm
Product HeightProduct Width
102 mm45 mm
Product WeightCertifications
0.319 kgVDE 0660
IEC/EN 60947
UL File No.: E36332
IEC/EN 60947-4-1
CSA File No.: 165628
UL Category Control No.: NLRV
UL
CSA-C22.2 No. 60947-4-1-14
CSA Class No.: 3211-05
CSA
UL 60947-4-1
CE
UL
CSA
Actuator type
Turn button
Features
Phase-failure sensitivity (according to IEC/EN 60947-4-1, VDE
0660 Part 102)
Functions
Phase failure sensitive
Motor protection
Number of poles
Three-pole
Lifespan, electrical
100,000 operations
Lifespan, mechanical
100,000 Operations
Mounting Method
DIN rail (top hat rail) mounting optional
Mounting position
Can be snapped on to IEC/EN 60715 top-hat rail with 7.5 or
15 mm height.
Operating frequency
40 Operations/h
Overvoltage category
III
Pollution degree
3
Product category
Motor protective circuit breaker
Protection
Finger and back-of-hand proof, Protection against direct contact
when actuated from front (EN 50274)
Rated impulse withstand voltage (Uimp)
6000 V AC
Shock resistance
25 g, Mechanical, according to IEC/EN 60068-2-27, Half-
sinusoidal shock 10 ms
Suitable for
Also motors with efficiency class IE3
Branch circuit: Manual type E if used with terminal, or suitable for
group installations, (UL/CSA)
Temperature compensation
-5 - 40 °C to IEC/EN 60947, VDE 0660
-25 - 55 °C, Operating range
≤ 0.25 %/K, residual error for T > 40°
Used with
Motor starter combinations
Altitude
Max. 2000 m
Ambient operating temperature - min
-25 °C
Ambient operating temperature - max
55 °C
Ambient operating temperature (enclosed) - min
-25 °C
Ambient operating temperature (enclosed) - max
40 °C
Ambient storage temperature - min
-40 °C
Ambient storage temperature - max
80 °C
Climatic proofing
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Short-circuit current rating (type E)
65 kA, 240 V, SCCR (UL/CSA) with contactor DILM17
65 kA, 480 Y/277 V, SCCR (UL/CSA) with contactor DILM17
Short-circuit release
248 A, Irm, Setting range max.
± 20% tolerance, Trip blocks
Basic device fixed 15.5 x Iu, Trip Blocks
Terminal capacity (flexible)
1 x (1 - 6) mm²
Stripping length (main cable)
12 mm
Tightening torque
1.7 Nm, Screw terminals, Main cable
Rated frequency - min
50 Hz
Rated frequency - max
60 Hz
Rated operational current (Ie)
16 A
Rated operational power at AC-3, 220/230 V, 50 Hz
4 kW
Rated operational power at AC-3, 380/400 V, 50 Hz
7.5 kW
Rated operational voltage (Ue) - min
690 V
Rated operational voltage (Ue) - max
690 V
Rated uninterrupted current (Iu)
16 A
Assigned motor power at 115/120 V, 60 Hz, 1-phase
1 HP
Assigned motor power at 200/208 V, 60 Hz, 3-phase
3 HP
Assigned motor power at 230/240 V, 60 Hz, 1-phase
2 HP
Assigned motor power at 230/240 V, 60 Hz, 3-phase
5 HP
Assigned motor power at 460/480 V, 60 Hz, 3-phase
10 HP
Assigned motor power at 575/600 V, 60 Hz, 3-phase
10 HP
Number of auxiliary contacts (change-over contacts)
0
Number of auxiliary contacts (normally closed contacts)
0
Number of auxiliary contacts (normally open contacts)
0
Equipment heat dissipation, current-dependent Pvid
6.43 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
0 W
Static heat dissipation, non-current-dependent Pvs
0 W
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to
normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal
elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be
Connection
Screw terminals on feed side
Push-in terminals on output side
Overload release current setting - min
16 A
Overload release current setting - max
16 A
Tripping characteristic
Overload trigger: tripping class 10 A
Brochures
Save time and space thanks to the new link module PKZM0-XDM32ME
Motor Starters in System xStart - brochure
Catalogs
Product Range Catalog Switching and protecting motors
Switching and protecting motors - catalog
Declarations of conformity
Drawings
121X002
121X042
eCAD model
Installation instructions
IL122024ZU
Installation videos
WIN-WIN with push-in technology
evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be
evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be
evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be
evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be
evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise
calculation. Eaton will provide heat dissipation data for the
devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the
switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the
switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in
mCAD model
pkzm0_s32_
pkzm0_s32_
the instruction leaflet (IL) is observed.
Eaton Corporation plc
Eaton House
30 Pembroke Road
Dublin 4, Ireland
Eaton is a registered trademark.
All other trademarks are
© 2023 Eaton. All Rights property of their respective
Reserved. owners.
/socialmedia